- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
327 lines
11 KiB
Text
327 lines
11 KiB
Text
-- ============================================================================
|
|
-- AT-FIBER-MONITORING-MIB, Allied Telesis enterprise MIB:
|
|
-- Fiber Monitoring MIB objects.
|
|
--
|
|
-- Copyright (c) 2015 by Allied Telesis, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ============================================================================
|
|
|
|
AT-FIBER-MONITORING-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sysinfo
|
|
FROM AT-SYSINFO-MIB
|
|
Integer32, Unsigned32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC;
|
|
|
|
atFiberMon MODULE-IDENTITY
|
|
LAST-UPDATED "201509080000Z"
|
|
ORGANIZATION
|
|
"Allied Telesis, Inc"
|
|
CONTACT-INFO
|
|
"http://www.alliedtelesis.com"
|
|
DESCRIPTION
|
|
"This MIB contains managed objects definition and notification
|
|
definitions for AT Fiber Monitoring feature."
|
|
REVISION "201509080000Z"
|
|
DESCRIPTION
|
|
"Initial revision"
|
|
::= { sysinfo 27 }
|
|
|
|
--
|
|
-- Textual conventions
|
|
--
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- Fiber Monitoring Notifications
|
|
-- ---------------------------------------------------------- --
|
|
atFiberMonNotifications OBJECT IDENTIFIER::= { atFiberMon 0 }
|
|
|
|
atFiberMonAlarmSetNotify NOTIFICATION-TYPE
|
|
OBJECTS { atFiberMonIfindex, atFiberMonChannel, atFiberMonIfname, atFiberMonReading,
|
|
atFiberMonThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A notification generated when the monitored received optical power of an SFP
|
|
goes outside its alarm threshold."
|
|
::= { atFiberMonNotifications 1 }
|
|
|
|
atFiberMonAlarmClearedNotify NOTIFICATION-TYPE
|
|
OBJECTS { atFiberMonIfindex, atFiberMonChannel, atFiberMonIfname, atFiberMonReading,
|
|
atFiberMonThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A notification generated when the monitored received optical power of an SFP
|
|
returns to an acceptable value. This can occur because the power has returned
|
|
to its previous level or the comparison baseline has adjusted to the new level."
|
|
::= { atFiberMonNotifications 2 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Notification variables
|
|
-- ---------------------------------------------------------- --
|
|
atFiberMonTrapVariable OBJECT IDENTIFIER::= { atFiberMon 1 }
|
|
|
|
atFiberMonReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current received optical power reading for the port specified
|
|
in the trap (x0.0001mW)"
|
|
::= { atFiberMonTrapVariable 1 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Fiber monitoring configuration objects
|
|
-- ---------------------------------------------------------- --
|
|
atFiberMonConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtFiberMonConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It contains the objects used to configure the operation of fiber monitoring."
|
|
::= { atFiberMon 2 }
|
|
|
|
atFiberMonConfigEntry OBJECT-TYPE
|
|
SYNTAX AtFiberMonConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for the table. It contains the configurables of fiber monitering for an interface."
|
|
INDEX { atFiberMonIfname }
|
|
::= { atFiberMonConfigTable 1 }
|
|
|
|
|
|
AtFiberMonConfigEntry ::=
|
|
SEQUENCE {
|
|
atFiberMonIfname
|
|
OCTET STRING,
|
|
atFiberMonEnable
|
|
INTEGER,
|
|
atFiberMonInterval
|
|
Integer32,
|
|
atFiberMonSensitivity
|
|
OCTET STRING,
|
|
atFiberMonBaseline
|
|
OCTET STRING,
|
|
atFiberMonAlarmAction
|
|
INTEGER
|
|
}
|
|
|
|
atFiberMonIfname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the interface where the pluggable is in."
|
|
::= { atFiberMonConfigEntry 1 }
|
|
|
|
atFiberMonEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable fiber monitoring."
|
|
::= { atFiberMonConfigEntry 2 }
|
|
|
|
atFiberMonInterval OBJECT-TYPE
|
|
SYNTAX Integer32 (2..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fiber monitoring polling interval in seconds."
|
|
::= { atFiberMonConfigEntry 3 }
|
|
|
|
atFiberMonSensitivity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sensitivity for fiber monitoring.
|
|
|
|
Acceptable mode strings and value ranges are as below:
|
|
|
|
low - 2dB
|
|
medium - 1dB
|
|
high - 0.5dB
|
|
highest - 0.0025mW
|
|
fixed <25 - 65535> - units of 0.0001mW
|
|
relative <0.00 - 10.00> - units of dB
|
|
|
|
For example, if you want to set the sensitivity to medium level, then you enter word
|
|
|
|
medium
|
|
|
|
Or if you want to set it to a fixed value, then you enter string
|
|
|
|
fixed 1000
|
|
|
|
Or if you want to set to a relative value, then you enter string
|
|
|
|
relative 1.20
|
|
"
|
|
::= { atFiberMonConfigEntry 4 }
|
|
|
|
atFiberMonBaseline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The baseline value for firber mornitoring.
|
|
|
|
Acceptable mode string and value ranges are as below:
|
|
|
|
average <12-150> - number of readings used to calculate moving average.
|
|
fixed <1-65535> - fixed baseline value in units of 0.0001mW.
|
|
|
|
For example, if you want to use a moving average of 12 readings as the baseline,
|
|
you enter
|
|
|
|
average 12
|
|
|
|
Or if you want to use a fixed value, though it is not recommended, you enter
|
|
|
|
fixed 500
|
|
"
|
|
::= { atFiberMonConfigEntry 5 }
|
|
|
|
atFiberMonAlarmAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
logOnly(1),
|
|
sendTrap(2),
|
|
shutdown(3),
|
|
sendtrapAndShutdown(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actions to take when an alarm occurs.
|
|
Acceptable values are:
|
|
1. Log a message only.
|
|
2. Send snmp trap and log.
|
|
3. Shut down the interface and log.
|
|
4. Send trap, shutdown and log.
|
|
"
|
|
::= { atFiberMonConfigEntry 6 }
|
|
|
|
-- ---------------------------------------------------------- --
|
|
-- Fiber monitoring state objects
|
|
-- ---------------------------------------------------------- --
|
|
atFiberMonStateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtFiberMonStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information of fiber monitoring state for SFPs."
|
|
::= { atFiberMon 3 }
|
|
|
|
atFiberMonStateEntry OBJECT-TYPE
|
|
SYNTAX AtFiberMonStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry for fiber monitoring state table. It contains state values for a fiber channel."
|
|
INDEX { atFiberMonIfindex, atFiberMonChannel }
|
|
::= { atFiberMonStateTable 1 }
|
|
|
|
AtFiberMonStateEntry ::=
|
|
SEQUENCE {
|
|
atFiberMonIfindex
|
|
Integer32,
|
|
atFiberMonChannel
|
|
INTEGER,
|
|
atFiberMonlIfDescription
|
|
DisplayString,
|
|
atFiberMonActualBaseline
|
|
Integer32,
|
|
atFiberMonThreshold
|
|
Integer32,
|
|
atFiberMonReadingHistory
|
|
DisplayString,
|
|
atFiberMonMinReading
|
|
Integer32,
|
|
atFiberMonMaxReading
|
|
Integer32
|
|
}
|
|
|
|
atFiberMonIfindex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the interface where the pluggable is in."
|
|
::= { atFiberMonStateEntry 1 }
|
|
|
|
atFiberMonChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The channel number of the pluggable."
|
|
::= { atFiberMonStateEntry 2 }
|
|
|
|
atFiberMonlIfDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface description. Normally it would be the name of the interface."
|
|
::= { atFiberMonStateEntry 3 }
|
|
|
|
atFiberMonActualBaseline OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The calculated baseline value for the link, in units of 0.0001mW."
|
|
::= { atFiberMonStateEntry 4 }
|
|
|
|
atFiberMonThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold value for alarm to occur, in units of 0.0001mW."
|
|
::= { atFiberMonStateEntry 5 }
|
|
|
|
atFiberMonReadingHistory OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reading history. It is a string containing last 12 readings."
|
|
::= { atFiberMonStateEntry 6 }
|
|
|
|
atFiberMonMinReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum reading of rx power, in units of 0.0001mW."
|
|
::= { atFiberMonStateEntry 7 }
|
|
|
|
atFiberMonMaxReading OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum reading of rx power, in units of 0.0001mW."
|
|
::= { atFiberMonStateEntry 8 }
|
|
|
|
|
|
END
|
|
|
|
--
|
|