- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
253 lines
7.9 KiB
Text
253 lines
7.9 KiB
Text
-- ============================================================================
|
|
-- AT-ALMMON-MIB, Allied Telesis enterprise MIB:
|
|
-- Alarm Monitoring MIB objects.
|
|
--
|
|
-- Copyright (c) 2014 by Allied Telesis, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- ============================================================================
|
|
|
|
AT-ALMMON-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayStringUnsized
|
|
FROM AT-SMI-MIB
|
|
sysinfo
|
|
FROM AT-SYSINFO-MIB
|
|
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC;
|
|
|
|
|
|
atAlmMon MODULE-IDENTITY
|
|
LAST-UPDATED "201702080000Z"
|
|
ORGANIZATION
|
|
"Allied Telesis, Inc"
|
|
CONTACT-INFO
|
|
"http://www.alliedtelesis.com"
|
|
DESCRIPTION
|
|
"The AT Alarm Monitoring MIB for managing and
|
|
reporting device alarms."
|
|
REVISION "201702080000Z"
|
|
DESCRIPTION
|
|
"Added g8032 as an alarm type."
|
|
REVISION "201405120015Z"
|
|
DESCRIPTION
|
|
"Changes from maintainer review"
|
|
REVISION "201312131146Z"
|
|
DESCRIPTION
|
|
"Initial Revision"
|
|
|
|
::= { sysinfo 26 }
|
|
|
|
|
|
|
|
--
|
|
-- Textual conventions
|
|
--
|
|
|
|
AtAlmMonAlarmType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the type of a monitored alarm."
|
|
SYNTAX INTEGER
|
|
{
|
|
alarmTypeInvalid(0),
|
|
externalPSU(1),
|
|
epsr(2),
|
|
contactInput(3),
|
|
portLinkDown(4),
|
|
loopDetect(5),
|
|
mainPse(6),
|
|
portPoeFailure(7),
|
|
temperature(8),
|
|
g8032(9)
|
|
}
|
|
|
|
|
|
AtAlmMonActionUseOutput ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether or not the output device (relay or fault LED) is used for this alarm."
|
|
SYNTAX INTEGER
|
|
{
|
|
unused(1),
|
|
used(2)
|
|
}
|
|
|
|
|
|
AtAlmMonAbnormalState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the abnormal (i.e. alarm active) state for a contact input alarm monitor."
|
|
SYNTAX INTEGER
|
|
{
|
|
open(1),
|
|
closed(2)
|
|
}
|
|
|
|
AtAlmMonActionState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of this alarm monitor."
|
|
SYNTAX INTEGER
|
|
{
|
|
inactive(1),
|
|
active(2)
|
|
}
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
-- ---------------------------------------------------------- --
|
|
-- The Alarm Monitoring actions table
|
|
-- ---------------------------------------------------------- --
|
|
|
|
atAlmMonActionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AtAlmMonActionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of information describing alarm monitoring inputs
|
|
and consequent actions (i.e. fault LED & relay outputs)."
|
|
::= { atAlmMon 1 }
|
|
|
|
|
|
atAlmMonActionEntry OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description and configuration of what to do for a specific monitored alarm."
|
|
INDEX { atAlmMonActionStackMemberId, atAlmMonActionIndex }
|
|
::= { atAlmMonActionTable 1 }
|
|
|
|
AtAlmMonActionEntry ::=
|
|
SEQUENCE {
|
|
atAlmMonActionStackMemberId
|
|
Unsigned32,
|
|
atAlmMonActionIndex
|
|
Unsigned32,
|
|
atAlmMonAlarmType
|
|
AtAlmMonAlarmType,
|
|
atAlmMonAlarmTypeSelection
|
|
Unsigned32,
|
|
atAlmMonActionDescription
|
|
DisplayStringUnsized,
|
|
atAlmMonActionUseRelay1
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseRelay2
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseRelay3
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonActionUseFaultLed
|
|
AtAlmMonActionUseOutput,
|
|
atAlmMonAbnormalState
|
|
AtAlmMonAbnormalState,
|
|
atAlmMonActionState
|
|
AtAlmMonActionState
|
|
}
|
|
|
|
atAlmMonActionStackMemberId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the stack member of this alarm action."
|
|
::= { atAlmMonActionEntry 1 }
|
|
|
|
|
|
atAlmMonActionIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The numeric identifier of this alarm action."
|
|
::= { atAlmMonActionEntry 2 }
|
|
|
|
|
|
atAlmMonAlarmType OBJECT-TYPE
|
|
SYNTAX AtAlmMonAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of alarm that this action monitors."
|
|
::= { atAlmMonActionEntry 3 }
|
|
|
|
|
|
atAlmMonAlarmTypeSelection OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 1-based index of the alarm of the particular type (as catagorised by atAlmMonAlarmType)."
|
|
::= { atAlmMonActionEntry 4 }
|
|
|
|
|
|
atAlmMonActionDescription OBJECT-TYPE
|
|
SYNTAX DisplayStringUnsized (SIZE (0..30))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The description of this alarm monitoring entry."
|
|
::= { atAlmMonActionEntry 5 }
|
|
|
|
|
|
atAlmMonActionUseRelay1 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the first relay output."
|
|
::= { atAlmMonActionEntry 6 }
|
|
|
|
|
|
atAlmMonActionUseRelay2 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the second relay output."
|
|
::= { atAlmMonActionEntry 7 }
|
|
|
|
atAlmMonActionUseRelay3 OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the third relay output."
|
|
::= { atAlmMonActionEntry 8 }
|
|
|
|
|
|
atAlmMonActionUseFaultLed OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionUseOutput
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/controls whether or not this alarm monitor drives the fault LED."
|
|
::= { atAlmMonActionEntry 9 }
|
|
|
|
atAlmMonAbnormalState OBJECT-TYPE
|
|
SYNTAX AtAlmMonAbnormalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates/sets the abnormal (i.e. alarm active) state for a contact input.
|
|
Only used for contactInput alarm monitors, ignored for all other types."
|
|
::= { atAlmMonActionEntry 10 }
|
|
|
|
|
|
atAlmMonActionState OBJECT-TYPE
|
|
SYNTAX AtAlmMonActionState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of this alarm monitor."
|
|
::= { atAlmMonActionEntry 11 }
|
|
|
|
END
|
|
|
|
--
|
|