towerops/priv/mibs/audiocodes/AC-PMPSTN-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

828 lines
23 KiB
Text

AC-PM-PSTN-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TAddress,
DisplayString,
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
IpAddress FROM RFC1155-SMI
Unsigned32,
Integer32,
Counter32,
Gauge32,
enterprises FROM SNMPv2-SMI
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
audioCodes,
acRegistrations,
acGeneric,
acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
acPMPSTN MODULE-IDENTITY
LAST-UPDATED "202005251042Z" --Monday, May 25 2020
ORGANIZATION "AudioCodes Ltd"
CONTACT-INFO
"Postal: Support
AudioCodes LTD
1 Hayarden Street
Airport City
Lod, ISRAEL 70151
Tel: 972-3-9764000
Fax: 972-3-9764040
Email: support@audiocodes.com
Web: www.audiocodes.com"
DESCRIPTION
"The AC-PM-PSTN MIB offers performance monitoring
For the PSTN related elements in Audiocodes' devices.
The Configuration sub-tree is for configuring the interval
Period length for the entire AC-PM-PSTN MIB, and the
different tables' thresholds.
The Data sub-tree presents the tables of monitored
elements.
Note - for the entire MIB the value (-1) means the value
Asked for is either not supported or currently not relevant
(this is for when values asked for are for intervals not yet
recorded."
REVISION "202102160955Z" --Tuesday, February 16 2021
DESCRIPTION "obsoleted acPMPSTN"
::= {acPerformance 10}
acPMPSTNConfiguration OBJECT IDENTIFIER ::= {acPMPSTN 1}
acPMPSTNConfigurationPeriodLength OBJECT-TYPE
SYNTAX Unsigned32 (0..894780)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Length of monitoring intervals for entire MIB. Time is in minutes.
Access: Instant."
::= {acPMPSTNConfiguration 1}
acPMPSTNConfigurationResetTotalCounters OBJECT-TYPE
SYNTAX INTEGER {
resetCountersDone(1)
,
resetTotalCounters(2)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Total-Counters Reset. To reset the total counters, set the
value of this object to resetTotalCounters(2).
Access: Instant."
::= {acPMPSTNConfiguration 2}
acPMTrunkUtilizationAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 31}
acPMTrunkUtilizationAttributesHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMTrunkUtilizationAttributes 1}
acPMTrunkUtilizationAttributesLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMTrunkUtilizationAttributes 2}
acPMPSTNChannelsAttributes OBJECT IDENTIFIER ::= {acPMPSTNConfiguration 32}
acPMPSTNChannelsAttributesInServiceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 1}
acPMPSTNChannelsAttributesInServiceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 2}
acPMPSTNChannelsAttributesOutOfServiceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 3}
acPMPSTNChannelsAttributesOutOfServiceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 4}
acPMPSTNChannelsAttributesInMaintenanceHighThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"High threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 5}
acPMPSTNChannelsAttributesInMaintenanceLowThreshold OBJECT-TYPE
SYNTAX Unsigned32 (0..32)
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION
"Low threshold.
Access: Instant."
::= {acPMPSTNChannelsAttributes 6}
acPMPSTNData OBJECT IDENTIFIER ::= {acPMPSTN 2}
acPMPSTNDataAcPMPSTNTimeFromStartOfInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The time in seconds since the start of the current interval.
MIB specific."
::= {acPMPSTNData 1}
-- ****************************************
-- acPMTrunkUtilization table declaration
-- ****************************************
acPMTrunkUtilizationTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMTrunkUtilizationEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Number of active channels per trunk (index: trunk number)."
::= {acPMPSTNData 21}
-- ****************************************
-- acPMTrunkUtilization table entry
-- ****************************************
acPMTrunkUtilizationEntry OBJECT-TYPE
SYNTAX AcPMTrunkUtilizationEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMTrunkUtilizationTrunkNum,acPMTrunkUtilizationInterval}
::= {acPMTrunkUtilizationTable 1}
-- ****************************************
-- acPMTrunkUtilization TABLE
-- ****************************************
AcPMTrunkUtilizationEntry ::= SEQUENCE {
acPMTrunkUtilizationTrunkNum Unsigned32,
acPMTrunkUtilizationInterval Unsigned32,
acPMTrunkUtilizationVal Gauge32,
acPMTrunkUtilizationAverage Integer32,
acPMTrunkUtilizationMax Integer32,
acPMTrunkUtilizationMin Integer32,
acPMTrunkUtilizationVolume Counter32,
acPMTrunkUtilizationTimeBelowLowThreshold Integer32,
acPMTrunkUtilizationTimeBetweenThresholds Integer32,
acPMTrunkUtilizationTimeAboveHighThreshold Integer32,
acPMTrunkUtilizationFullDayAverage Integer32,
acPMTrunkUtilizationTotal Integer32
}
acPMTrunkUtilizationTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMTrunkUtilizationEntry 1}
acPMTrunkUtilizationInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMTrunkUtilizationEntry 2}
acPMTrunkUtilizationVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMTrunkUtilizationEntry 3}
acPMTrunkUtilizationAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMTrunkUtilizationEntry 4}
acPMTrunkUtilizationMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMTrunkUtilizationEntry 5}
acPMTrunkUtilizationMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMTrunkUtilizationEntry 6}
acPMTrunkUtilizationVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMTrunkUtilizationEntry 7}
acPMTrunkUtilizationTimeBelowLowThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is below what was determined
as the low threshold."
::= {acPMTrunkUtilizationEntry 8}
acPMTrunkUtilizationTimeBetweenThresholds OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is above what was determined
as the high threshold."
::= {acPMTrunkUtilizationEntry 9}
acPMTrunkUtilizationTimeAboveHighThreshold OBJECT-TYPE
SYNTAX Integer32 (-1..100)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Percent of interval time for which gauge is between what were
determined as the low and high thresholds."
::= {acPMTrunkUtilizationEntry 10}
acPMTrunkUtilizationFullDayAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"The average of full 24 hours."
::= {acPMTrunkUtilizationEntry 11}
acPMTrunkUtilizationTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Total since last reset."
::= {acPMTrunkUtilizationEntry 12}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds table declaration
-- ****************************************
acPMPSTNTrunkActivitySecondsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNTrunkActivitySecondsEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Counts activity seconds on the trunk."
::= {acPMPSTNData 22}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds table entry
-- ****************************************
acPMPSTNTrunkActivitySecondsEntry OBJECT-TYPE
SYNTAX AcPMPSTNTrunkActivitySecondsEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMPSTNTrunkActivitySecondsTrunkNum,acPMPSTNTrunkActivitySecondsInterval}
::= {acPMPSTNTrunkActivitySecondsTable 1}
-- ****************************************
-- acPMPSTNTrunkActivitySeconds TABLE
-- ****************************************
AcPMPSTNTrunkActivitySecondsEntry ::= SEQUENCE {
acPMPSTNTrunkActivitySecondsTrunkNum Unsigned32,
acPMPSTNTrunkActivitySecondsInterval Unsigned32,
acPMPSTNTrunkActivitySecondsVal Gauge32,
acPMPSTNTrunkActivitySecondsTotal Integer32,
acPMPSTNTrunkActivitySecondsVolume Counter32
}
acPMPSTNTrunkActivitySecondsTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNTrunkActivitySecondsEntry 1}
acPMPSTNTrunkActivitySecondsInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNTrunkActivitySecondsEntry 2}
acPMPSTNTrunkActivitySecondsVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNTrunkActivitySecondsEntry 3}
acPMPSTNTrunkActivitySecondsTotal OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Total since last reset."
::= {acPMPSTNTrunkActivitySecondsEntry 4}
acPMPSTNTrunkActivitySecondsVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMPSTNTrunkActivitySecondsEntry 5}
acPMPSTNChannels OBJECT IDENTIFIER ::= {acPMPSTNData 31}
-- ****************************************
-- acPMPSTNNumOfChannelsInService table declaration
-- ****************************************
acPMPSTNNumOfChannelsInServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInServiceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Channels in service, per trunk."
::= {acPMPSTNChannels 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInService table entry
-- ****************************************
acPMPSTNNumOfChannelsInServiceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsInServiceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsInServiceTrunkNum,acPMPSTNNumOfChannelsInServiceInterval}
::= {acPMPSTNNumOfChannelsInServiceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInService TABLE
-- ****************************************
AcPMPSTNNumOfChannelsInServiceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsInServiceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsInServiceInterval Unsigned32,
acPMPSTNNumOfChannelsInServiceVal Gauge32,
acPMPSTNNumOfChannelsInServiceAverage Integer32,
acPMPSTNNumOfChannelsInServiceMax Integer32,
acPMPSTNNumOfChannelsInServiceMin Integer32,
acPMPSTNNumOfChannelsInServiceVolume Counter32
}
acPMPSTNNumOfChannelsInServiceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsInServiceEntry 1}
acPMPSTNNumOfChannelsInServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsInServiceEntry 2}
acPMPSTNNumOfChannelsInServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsInServiceEntry 3}
acPMPSTNNumOfChannelsInServiceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 4}
acPMPSTNNumOfChannelsInServiceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 5}
acPMPSTNNumOfChannelsInServiceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsInServiceEntry 6}
acPMPSTNNumOfChannelsInServiceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsInServiceEntry 7}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService table declaration
-- ****************************************
acPMPSTNNumOfChannelsOutOfServiceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Channels out of service, per trunk."
::= {acPMPSTNChannels 2}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService table entry
-- ****************************************
acPMPSTNNumOfChannelsOutOfServiceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsOutOfServiceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsOutOfServiceTrunkNum,acPMPSTNNumOfChannelsOutOfServiceInterval}
::= {acPMPSTNNumOfChannelsOutOfServiceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsOutOfService TABLE
-- ****************************************
AcPMPSTNNumOfChannelsOutOfServiceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsOutOfServiceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsOutOfServiceInterval Unsigned32,
acPMPSTNNumOfChannelsOutOfServiceVal Gauge32,
acPMPSTNNumOfChannelsOutOfServiceAverage Integer32,
acPMPSTNNumOfChannelsOutOfServiceMax Integer32,
acPMPSTNNumOfChannelsOutOfServiceMin Integer32,
acPMPSTNNumOfChannelsOutOfServiceVolume Counter32
}
acPMPSTNNumOfChannelsOutOfServiceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 1}
acPMPSTNNumOfChannelsOutOfServiceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 2}
acPMPSTNNumOfChannelsOutOfServiceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 3}
acPMPSTNNumOfChannelsOutOfServiceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 4}
acPMPSTNNumOfChannelsOutOfServiceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 5}
acPMPSTNNumOfChannelsOutOfServiceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 6}
acPMPSTNNumOfChannelsOutOfServiceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsOutOfServiceEntry 7}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance table declaration
-- ****************************************
acPMPSTNNumOfChannelsInMaintenanceTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcPMPSTNNumOfChannelsInMaintenanceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Channels in maintenance status (not in-service), per trunk."
::= {acPMPSTNChannels 3}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance table entry
-- ****************************************
acPMPSTNNumOfChannelsInMaintenanceEntry OBJECT-TYPE
SYNTAX AcPMPSTNNumOfChannelsInMaintenanceEntry
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
""
INDEX {acPMPSTNNumOfChannelsInMaintenanceTrunkNum,acPMPSTNNumOfChannelsInMaintenanceInterval}
::= {acPMPSTNNumOfChannelsInMaintenanceTable 1}
-- ****************************************
-- acPMPSTNNumOfChannelsInMaintenance TABLE
-- ****************************************
AcPMPSTNNumOfChannelsInMaintenanceEntry ::= SEQUENCE {
acPMPSTNNumOfChannelsInMaintenanceTrunkNum Unsigned32,
acPMPSTNNumOfChannelsInMaintenanceInterval Unsigned32,
acPMPSTNNumOfChannelsInMaintenanceVal Gauge32,
acPMPSTNNumOfChannelsInMaintenanceAverage Integer32,
acPMPSTNNumOfChannelsInMaintenanceMax Integer32,
acPMPSTNNumOfChannelsInMaintenanceMin Integer32,
acPMPSTNNumOfChannelsInMaintenanceVolume Counter32
}
acPMPSTNNumOfChannelsInMaintenanceTrunkNum OBJECT-TYPE
SYNTAX Unsigned32 (0..83)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Trunk number.
0 is the first trunk."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 1}
acPMPSTNNumOfChannelsInMaintenanceInterval OBJECT-TYPE
SYNTAX Unsigned32 (0..2)
MAX-ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"Interval index.
0 - current period (incomplete monitoring - mid period).
1 - Last full period.
2 - One before last."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 2}
acPMPSTNNumOfChannelsInMaintenanceVal OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Value of gauge or counter."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 3}
acPMPSTNNumOfChannelsInMaintenanceAverage OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Average value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 4}
acPMPSTNNumOfChannelsInMaintenanceMax OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Maximum value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 5}
acPMPSTNNumOfChannelsInMaintenanceMin OBJECT-TYPE
SYNTAX Integer32 (-1..2147483647)
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Minimum value within the period time."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 6}
acPMPSTNNumOfChannelsInMaintenanceVolume OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"Activity volume."
::= {acPMPSTNNumOfChannelsInMaintenanceEntry 7}
END