- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
48678 lines
1.8 MiB
48678 lines
1.8 MiB
ABBMODULARUPS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--
|
|
-- Modular UPS data
|
|
--
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
OBJECT-IDENTITY, Counter32, Gauge32, Integer32, Unsigned32,
|
|
enterprises
|
|
FROM SNMPv2-SMI
|
|
DisplayString, TimeStamp, TimeInterval, TestAndIncr,
|
|
AutonomousType, TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
|
|
abb MODULE-IDENTITY
|
|
LAST-UPDATED "201911190000Z"
|
|
ORGANIZATION "ABB Power Protection SA"
|
|
CONTACT-INFO
|
|
"ABB Power Protection SA
|
|
Via Luserte Sud 9
|
|
6572 Quartino
|
|
Switzerland"
|
|
DESCRIPTION
|
|
"The MIB module to describe ABB Power Protection SA
|
|
Uninterruptible Power Supplies."
|
|
REVISION "201911190000Z"
|
|
DESCRIPTION
|
|
"Unique objects name version "
|
|
REVISION "201911010000Z"
|
|
DESCRIPTION
|
|
"Read-Only version "
|
|
REVISION "201907290000Z"
|
|
DESCRIPTION
|
|
"Initial version "
|
|
::= { enterprises 53973 }
|
|
|
|
|
|
PositiveInteger ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This data type is a non-zero and non-negative value."
|
|
SYNTAX Integer32 (1..2147483647)
|
|
|
|
NonNegativeInteger ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This data type is a non-negative value."
|
|
SYNTAX Integer32 (0..2147483647)
|
|
|
|
ups OBJECT IDENTIFIER ::= { abb 1 }
|
|
|
|
upsModular OBJECT IDENTIFIER ::= { ups 1 }
|
|
|
|
--
|
|
-- System data
|
|
--
|
|
|
|
upsSystem OBJECT IDENTIFIER ::= { upsModular 1 }
|
|
|
|
upsModularDiscoveredUPSsMask OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reading this variable returns bit mask indicating which
|
|
module in a parallel system is alive.
|
|
|
|
1 Module 1 alive
|
|
2 Module 2 alive
|
|
4 Module 3 alive
|
|
8 Module 4 alive
|
|
16 Module 5 alive
|
|
32 Module 6 alive
|
|
64 Module 7 alive
|
|
128 Module 8 alive
|
|
256 Module 9 alive
|
|
512 Module 10 alive
|
|
1024 Module 11 alive
|
|
2048 Module 12 alive
|
|
4096 Module 13 alive
|
|
8192 Module 14 alive
|
|
16384 Module 15 alive
|
|
32768 Module 16 alive
|
|
65536 Module 17 alive
|
|
131072 Module 18 alive
|
|
262144 Module 19 alive
|
|
524288 Module 20 alive
|
|
1048576 Module 21 alive
|
|
2097152 Module 22 alive
|
|
4194304 Module 23 alive
|
|
8388608 Module 24 alive
|
|
16777216 Module 25 alive
|
|
33554432 Module 26 alive
|
|
67108864 Module 27 alive
|
|
134217728 Module 28 alive
|
|
268435456 Module 29 alive
|
|
536870912 Module 30 alive
|
|
"
|
|
::= { upsSystem 4 }
|
|
|
|
upsObjects OBJECT IDENTIFIER ::= { upsSystem 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for upsIdentName and
|
|
-- upsIdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
upsIdent OBJECT IDENTIFIER ::= { upsObjects 1 }
|
|
|
|
upsIdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { upsIdent 1 }
|
|
|
|
upsIdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { upsIdent 2 }
|
|
|
|
upsIdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
upsIdentAgentSoftwareVersion in some implementations."
|
|
::= { upsIdent 3 }
|
|
|
|
upsIdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
upsIdentUPSSoftwareVersion in some implementations."
|
|
::= { upsIdent 4 }
|
|
|
|
upsIdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { upsIdent 5 }
|
|
|
|
upsIdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { upsIdent 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
upsBattery OBJECT IDENTIFIER ::= { upsObjects 2 }
|
|
|
|
upsBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
upsConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to upsConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { upsBattery 1 }
|
|
|
|
upsSecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { upsBattery 2 }
|
|
|
|
upsEstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { upsBattery 3 }
|
|
|
|
upsEstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { upsBattery 4 }
|
|
|
|
upsBatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { upsBattery 5 }
|
|
|
|
upsBatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { upsBattery 6 }
|
|
|
|
upsBatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { upsBattery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
upsInput OBJECT IDENTIFIER ::= { upsObjects 3 }
|
|
|
|
upsInputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { upsInput 1 }
|
|
|
|
|
|
upsInputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { upsInput 2 }
|
|
|
|
upsInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of upsInputNumLines."
|
|
::= { upsInput 3 }
|
|
|
|
upsInputEntry OBJECT-TYPE
|
|
SYNTAX UpsInputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { upsInputLineIndex }
|
|
::= { upsInputTable 1 }
|
|
|
|
UpsInputEntry ::= SEQUENCE {
|
|
upsInputLineIndex PositiveInteger,
|
|
upsInputFrequency NonNegativeInteger,
|
|
upsInputVoltage NonNegativeInteger,
|
|
upsInputCurrent NonNegativeInteger
|
|
}
|
|
|
|
upsInputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { upsInputEntry 1 }
|
|
|
|
upsInputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { upsInputEntry 2 }
|
|
|
|
upsInputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { upsInputEntry 3 }
|
|
|
|
upsInputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { upsInputEntry 4 }
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
upsOutput OBJECT IDENTIFIER ::= { upsObjects 4 }
|
|
|
|
upsOutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { upsOutput 1 }
|
|
|
|
upsOutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { upsOutput 2 }
|
|
|
|
upsOutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { upsOutput 3 }
|
|
|
|
upsOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of upsOutputNumLines."
|
|
::= { upsOutput 4 }
|
|
|
|
upsOutputEntry OBJECT-TYPE
|
|
SYNTAX UpsOutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { upsOutputLineIndex }
|
|
::= { upsOutputTable 1 }
|
|
|
|
UpsOutputEntry ::= SEQUENCE {
|
|
upsOutputLineIndex PositiveInteger,
|
|
upsOutputVoltage NonNegativeInteger,
|
|
upsOutputCurrent NonNegativeInteger,
|
|
upsOutputPower NonNegativeInteger,
|
|
upsOutputPercentLoad INTEGER
|
|
}
|
|
|
|
upsOutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { upsOutputEntry 1 }
|
|
|
|
upsOutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { upsOutputEntry 2 }
|
|
|
|
upsOutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { upsOutputEntry 3 }
|
|
|
|
upsOutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { upsOutputEntry 4 }
|
|
|
|
upsOutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { upsOutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
upsBypass OBJECT IDENTIFIER ::= { upsObjects 5 }
|
|
|
|
upsBypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { upsBypass 1 }
|
|
|
|
upsBypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { upsBypass 2 }
|
|
|
|
upsBypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of upsBypassNumLines."
|
|
::= { upsBypass 3 }
|
|
|
|
upsBypassEntry OBJECT-TYPE
|
|
SYNTAX UpsBypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { upsBypassLineIndex }
|
|
::= { upsBypassTable 1 }
|
|
|
|
UpsBypassEntry ::= SEQUENCE {
|
|
upsBypassLineIndex PositiveInteger,
|
|
upsBypassVoltage NonNegativeInteger,
|
|
upsBypassCurrent NonNegativeInteger,
|
|
upsBypassPower NonNegativeInteger
|
|
}
|
|
|
|
upsBypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { upsBypassEntry 1 }
|
|
|
|
upsBypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { upsBypassEntry 2 }
|
|
|
|
upsBypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { upsBypassEntry 3 }
|
|
|
|
upsBypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { upsBypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
upsAlarm OBJECT IDENTIFIER ::= { upsObjects 6 }
|
|
|
|
upsAlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { upsAlarm 1 }
|
|
|
|
upsAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
upsAlarmId equal to 1, and increments the value of
|
|
upsAlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of upsAlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
upsAlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), upsAlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of upsAlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of upsAlarmsPresent."
|
|
::= { upsAlarm 2 }
|
|
|
|
upsAlarmEntry OBJECT-TYPE
|
|
SYNTAX UpsAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { upsAlarmId }
|
|
::= { upsAlarmTable 1 }
|
|
|
|
UpsAlarmEntry ::= SEQUENCE {
|
|
upsAlarmId PositiveInteger,
|
|
upsAlarmDescr AutonomousType,
|
|
upsAlarmTime TimeStamp
|
|
}
|
|
|
|
upsAlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { upsAlarmEntry 1 }
|
|
|
|
upsAlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { upsAlarmEntry 2 }
|
|
|
|
upsAlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of upsAlarmTime shall equal
|
|
0."
|
|
::= { upsAlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
upsWellKnownAlarms OBJECT IDENTIFIER ::= { upsAlarm 3 }
|
|
upsAlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { upsWellKnownAlarms 1 }
|
|
|
|
upsAlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { upsWellKnownAlarms 2 }
|
|
|
|
upsAlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to upsConfigLowBattTime."
|
|
::= { upsWellKnownAlarms 3 }
|
|
|
|
|
|
upsAlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { upsWellKnownAlarms 4 }
|
|
|
|
upsAlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { upsWellKnownAlarms 5 }
|
|
|
|
upsAlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { upsWellKnownAlarms 6 }
|
|
|
|
upsAlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { upsWellKnownAlarms 7 }
|
|
|
|
upsAlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { upsWellKnownAlarms 8 }
|
|
|
|
upsAlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { upsWellKnownAlarms 9 }
|
|
|
|
upsAlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { upsWellKnownAlarms 10 }
|
|
|
|
upsAlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { upsWellKnownAlarms 11 }
|
|
|
|
upsAlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { upsWellKnownAlarms 12 }
|
|
|
|
upsAlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { upsWellKnownAlarms 13 }
|
|
|
|
upsAlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { upsWellKnownAlarms 14 }
|
|
|
|
upsAlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { upsWellKnownAlarms 15 }
|
|
|
|
upsAlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { upsWellKnownAlarms 16 }
|
|
|
|
upsAlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { upsWellKnownAlarms 17 }
|
|
|
|
upsAlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { upsWellKnownAlarms 18 }
|
|
|
|
upsAlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { upsWellKnownAlarms 19 }
|
|
|
|
upsAlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { upsWellKnownAlarms 20 }
|
|
|
|
upsAlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { upsWellKnownAlarms 21 }
|
|
|
|
upsAlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A upsShutdownAfterDelay countdown is underway."
|
|
::= { upsWellKnownAlarms 22 }
|
|
|
|
upsAlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { upsWellKnownAlarms 23 }
|
|
|
|
upsAlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { upsWellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
upsTest OBJECT IDENTIFIER ::= { upsObjects 7 }
|
|
|
|
upsTestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
upsTestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
upsTestResultsSummary. Tests in progress may be
|
|
aborted by setting the upsTestId variable to
|
|
upsTestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value upsTestNoTestsInitiated is returned."
|
|
::= { upsTest 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
upsTestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = upsTestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, upsTestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
upsTestResultsSummary */
|
|
get (upsTestSpinLock, upsTestResultsSummary,
|
|
upsTestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, upsTestResultsSummary,
|
|
upsTestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if upsTestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of upsTestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { upsTest 2 }
|
|
|
|
upsTestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of upsTestId to upsTestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { upsTest 3 }
|
|
|
|
upsTestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about upsTestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { upsTest 4 }
|
|
|
|
upsTestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of upsTestResultsSummary is noTestsInitiated(6),
|
|
upsTestStartTime has the value 0."
|
|
::= { upsTest 5 }
|
|
|
|
upsTestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
upsTestResultsSummary is noTestsInitiated(6),
|
|
upsTestElapsedTime has the value 0."
|
|
::= { upsTest 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
upsWellKnownTests OBJECT IDENTIFIER ::= { upsTest 7 }
|
|
|
|
|
|
upsTestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { upsWellKnownTests 1 }
|
|
|
|
upsTestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { upsWellKnownTests 2 }
|
|
|
|
upsTestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { upsWellKnownTests 3 }
|
|
|
|
upsTestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { upsWellKnownTests 4 }
|
|
|
|
upsTestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { upsWellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
upsControl OBJECT IDENTIFIER ::= { upsObjects 8 }
|
|
|
|
upsShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
upsShutdownAfterDelay and upsRebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { upsControl 1 }
|
|
|
|
upsShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of upsShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if upsShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if upsShutdownType =
|
|
output and the output is already off. When read,
|
|
upsShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any upsShutdownAfterDelay already in effect."
|
|
::= { upsControl 2 }
|
|
|
|
upsStartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any upsStartupAfterDelay
|
|
countdown or upsRebootWithDuration countdown in
|
|
progress. When read, upsStartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { upsControl 3 }
|
|
|
|
upsRebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of upsShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, upsRebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { upsControl 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
upsTraps OBJECT IDENTIFIER ::= { upsSystem 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
upsTrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { upsEstimatedMinutesRemaining, upsSecondsOnBattery,
|
|
upsConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { upsTraps 1 }
|
|
|
|
upsTrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { upsTestId, upsTestSpinLock,
|
|
upsTestResultsSummary, upsTestResultsDetail,
|
|
upsTestStartTime, upsTestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { upsTraps 2 }
|
|
|
|
upsTrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { upsAlarmId, upsAlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for upsAlarmOnBattery and
|
|
upsAlarmTestInProgress."
|
|
::= { upsTraps 3 }
|
|
|
|
upsTrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { upsAlarmId, upsAlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for upsAlarmTestInProgress."
|
|
::= { upsTraps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
upsConformance OBJECT IDENTIFIER ::= { upsSystem 3 }
|
|
|
|
upsCompliances OBJECT IDENTIFIER ::= { upsConformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
upsSubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { upsSubsetIdentGroup,
|
|
upsSubsetBatteryGroup, upsSubsetInputGroup,
|
|
upsSubsetOutputGroup, upsSubsetAlarmGroup,
|
|
upsSubsetControlGroup }
|
|
|
|
OBJECT upsBatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT upsAlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: upsAlarmOnBattery, upsAlarmLowBattery,
|
|
upsAlarmInputBad, upsAlarmUpsOutputOff,
|
|
upsAlarmUpsSystemOff, and upsAlarmTestInProgress."
|
|
|
|
OBJECT upsOutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT upsShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { upsCompliances 1 }
|
|
|
|
upsBasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { upsBasicIdentGroup,
|
|
upsBasicBatteryGroup, upsBasicInputGroup,
|
|
upsBasicOutputGroup, upsBasicAlarmGroup,
|
|
upsBasicTestGroup, upsBasicControlGroup }
|
|
|
|
|
|
OBJECT upsAlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: upsAlarmOnBattery, upsAlarmLowBattery,
|
|
upsAlarmDepletedBattery, upsAlarmTempBad,
|
|
upsAlarmInputBad, upsAlarmOutputOverload,
|
|
upsAlarmOnBypass, upsAlarmBypassBad,
|
|
upsAlarmOutputOffAsRequested,
|
|
upsAlarmUpsOffAsRequested, upsAlarmUpsOutputOff,
|
|
upsAlarmUpsSystemOff, upsAlarmGeneralFault,
|
|
upsAlarmDiagnosticTestFailed,
|
|
upsAlarmCommunicationsLost, upsAlarmShutdownPending,
|
|
and upsAlarmTestInProgress."
|
|
|
|
OBJECT upsTestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
upsTestNoTestsInitiated."
|
|
|
|
OBJECT upsOutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP upsBasicBypassGroup
|
|
DESCRIPTION
|
|
"The upsBasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT upsShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { upsCompliances 2 }
|
|
|
|
upsFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { upsFullIdentGroup, upsFullBatteryGroup,
|
|
upsFullInputGroup, upsFullOutputGroup,
|
|
upsFullAlarmGroup, upsFullTestGroup,
|
|
upsFullControlGroup }
|
|
|
|
OBJECT upsAlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: upsAlarmBatteryBad, upsAlarmOnBattery,
|
|
upsAlarmLowBattery, upsAlarmDepletedBattery,
|
|
upsAlarmTempBad, upsAlarmInputBad, upsAlarmOnBypass,
|
|
upsAlarmBypassBad, upsAlarmOutputOffAsRequested,
|
|
upsAlarmUpsOffAsRequested, upsAlarmUpsOutputOff,
|
|
upsAlarmUpsSystemOff, upsAlarmGeneralFault,
|
|
upsAlarmDiagnosticTestFailed,
|
|
upsAlarmCommunicationsLost, upsAlarmShutdownPending,
|
|
and upsAlarmTestInProgress."
|
|
|
|
OBJECT upsTestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: upsTestNoTestsInitiated,
|
|
upsTestGeneralSystemsTest, and
|
|
upsTestQuickBatteryTest."
|
|
|
|
OBJECT upsOutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP upsFullBypassGroup
|
|
DESCRIPTION
|
|
"The upsFullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT upsShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { upsCompliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
upsGroups OBJECT IDENTIFIER ::= { upsConformance 2 }
|
|
|
|
upsSubsetGroups OBJECT IDENTIFIER ::= { upsGroups 1 }
|
|
|
|
upsSubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { upsIdentManufacturer, upsIdentModel,
|
|
upsIdentAgentSoftwareVersion, upsIdentName,
|
|
upsIdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the upsSubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { upsSubsetGroups 1 }
|
|
|
|
upsSubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { upsBatteryStatus, upsSecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { upsSubsetGroups 2 }
|
|
|
|
upsSubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { upsInputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { upsSubsetGroups 3 }
|
|
|
|
upsSubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { upsOutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { upsSubsetGroups 4 }
|
|
|
|
|
|
-- { upsSubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
upsSubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { upsAlarmsPresent, upsAlarmDescr, upsAlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { upsSubsetGroups 6 }
|
|
|
|
-- { upsSubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
upsSubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { upsShutdownType, upsShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsSubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { upsSubsetGroups 8 }
|
|
|
|
upsBasicGroups OBJECT IDENTIFIER ::= { upsGroups 2 }
|
|
|
|
upsBasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { upsIdentManufacturer, upsIdentModel,
|
|
upsIdentUPSSoftwareVersion,
|
|
upsIdentAgentSoftwareVersion, upsIdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 1 }
|
|
|
|
upsBasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { upsBatteryStatus, upsSecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 2 }
|
|
|
|
upsBasicInputGroup OBJECT-GROUP
|
|
OBJECTS { upsInputLineBads, upsInputNumLines,
|
|
upsInputFrequency, upsInputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 3 }
|
|
|
|
upsBasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { upsOutputSource, upsOutputFrequency,
|
|
upsOutputNumLines, upsOutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 4 }
|
|
|
|
upsBasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { upsBypassFrequency, upsBypassNumLines,
|
|
upsBypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 5 }
|
|
|
|
upsBasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { upsAlarmsPresent, upsAlarmDescr, upsAlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The upsBasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 6 }
|
|
|
|
upsBasicTestGroup OBJECT-GROUP
|
|
OBJECTS { upsTestId, upsTestSpinLock,
|
|
upsTestResultsSummary, upsTestResultsDetail,
|
|
upsTestStartTime, upsTestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 7 }
|
|
|
|
upsBasicControlGroup OBJECT-GROUP
|
|
OBJECTS { upsShutdownType, upsShutdownAfterDelay,
|
|
upsStartupAfterDelay, upsRebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsBasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { upsBasicGroups 8 }
|
|
|
|
upsFullGroups OBJECT IDENTIFIER ::= { upsGroups 3 }
|
|
|
|
upsFullIdentGroup OBJECT-GROUP
|
|
OBJECTS { upsIdentManufacturer, upsIdentModel,
|
|
upsIdentUPSSoftwareVersion,
|
|
upsIdentAgentSoftwareVersion, upsIdentName,
|
|
upsIdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { upsFullGroups 1 }
|
|
|
|
upsFullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { upsBatteryStatus, upsSecondsOnBattery,
|
|
upsEstimatedMinutesRemaining,
|
|
upsEstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { upsFullGroups 2 }
|
|
|
|
upsFullInputGroup OBJECT-GROUP
|
|
OBJECTS { upsInputLineBads, upsInputNumLines,
|
|
upsInputFrequency, upsInputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { upsFullGroups 3 }
|
|
|
|
upsFullOutputGroup OBJECT-GROUP
|
|
OBJECTS { upsOutputSource, upsOutputFrequency,
|
|
upsOutputNumLines, upsOutputVoltage,
|
|
upsOutputCurrent, upsOutputPower,
|
|
upsOutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { upsFullGroups 4 }
|
|
|
|
upsFullBypassGroup OBJECT-GROUP
|
|
OBJECTS { upsBypassFrequency, upsBypassNumLines,
|
|
upsBypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { upsFullGroups 5 }
|
|
|
|
upsFullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { upsAlarmsPresent, upsAlarmDescr, upsAlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The upsFullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { upsFullGroups 6 }
|
|
|
|
upsFullTestGroup OBJECT-GROUP
|
|
OBJECTS { upsTestId, upsTestSpinLock,
|
|
upsTestResultsSummary, upsTestResultsDetail,
|
|
upsTestStartTime, upsTestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { upsFullGroups 7 }
|
|
|
|
upsFullControlGroup OBJECT-GROUP
|
|
OBJECTS { upsShutdownType, upsShutdownAfterDelay,
|
|
upsStartupAfterDelay, upsRebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upsFullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { upsFullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 1 data
|
|
--
|
|
|
|
upsModule1 OBJECT IDENTIFIER ::= { upsModular 2 }
|
|
|
|
ups01Objects OBJECT IDENTIFIER ::= { upsModule1 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups01IdentName and
|
|
-- ups01IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups01Ident OBJECT IDENTIFIER ::= { ups01Objects 1 }
|
|
|
|
ups01IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups01Ident 1 }
|
|
|
|
ups01IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups01Ident 2 }
|
|
|
|
ups01IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups01IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups01Ident 3 }
|
|
|
|
ups01IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups01IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups01Ident 4 }
|
|
|
|
ups01IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups01Ident 5 }
|
|
|
|
ups01IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups01Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups01Battery OBJECT IDENTIFIER ::= { ups01Objects 2 }
|
|
|
|
ups01BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups01ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups01ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups01Battery 1 }
|
|
|
|
ups01SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups01Battery 2 }
|
|
|
|
ups01EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups01Battery 3 }
|
|
|
|
ups01EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups01Battery 4 }
|
|
|
|
ups01BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups01Battery 5 }
|
|
|
|
ups01BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups01Battery 6 }
|
|
|
|
ups01BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups01Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups01Input OBJECT IDENTIFIER ::= { ups01Objects 3 }
|
|
|
|
ups01InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups01Input 1 }
|
|
|
|
|
|
ups01InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups01Input 2 }
|
|
|
|
ups01InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups01InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups01InputNumLines."
|
|
::= { ups01Input 3 }
|
|
|
|
ups01InputEntry OBJECT-TYPE
|
|
SYNTAX Ups01InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups01InputLineIndex }
|
|
::= { ups01InputTable 1 }
|
|
|
|
Ups01InputEntry ::= SEQUENCE {
|
|
ups01InputLineIndex PositiveInteger,
|
|
ups01InputFrequency NonNegativeInteger,
|
|
ups01InputVoltage NonNegativeInteger,
|
|
ups01InputCurrent NonNegativeInteger,
|
|
ups01InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups01InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups01InputEntry 1 }
|
|
|
|
ups01InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups01InputEntry 2 }
|
|
|
|
ups01InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups01InputEntry 3 }
|
|
|
|
ups01InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups01InputEntry 4 }
|
|
|
|
ups01InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups01InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups01Output OBJECT IDENTIFIER ::= { ups01Objects 4 }
|
|
|
|
ups01OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups01Output 1 }
|
|
|
|
ups01OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups01Output 2 }
|
|
|
|
ups01OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups01Output 3 }
|
|
|
|
ups01OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups01OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups01OutputNumLines."
|
|
::= { ups01Output 4 }
|
|
|
|
ups01OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups01OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups01OutputLineIndex }
|
|
::= { ups01OutputTable 1 }
|
|
|
|
Ups01OutputEntry ::= SEQUENCE {
|
|
ups01OutputLineIndex PositiveInteger,
|
|
ups01OutputVoltage NonNegativeInteger,
|
|
ups01OutputCurrent NonNegativeInteger,
|
|
ups01OutputPower NonNegativeInteger,
|
|
ups01OutputPercentLoad Integer32
|
|
}
|
|
|
|
ups01OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups01OutputEntry 1 }
|
|
|
|
ups01OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups01OutputEntry 2 }
|
|
|
|
ups01OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups01OutputEntry 3 }
|
|
|
|
ups01OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups01OutputEntry 4 }
|
|
|
|
ups01OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups01OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups01Bypass OBJECT IDENTIFIER ::= { ups01Objects 5 }
|
|
|
|
ups01BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups01Bypass 1 }
|
|
|
|
ups01BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups01Bypass 2 }
|
|
|
|
ups01BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups01BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups01BypassNumLines."
|
|
::= { ups01Bypass 3 }
|
|
|
|
ups01BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups01BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups01BypassLineIndex }
|
|
::= { ups01BypassTable 1 }
|
|
|
|
Ups01BypassEntry ::= SEQUENCE {
|
|
ups01BypassLineIndex PositiveInteger,
|
|
ups01BypassVoltage NonNegativeInteger,
|
|
ups01BypassCurrent NonNegativeInteger,
|
|
ups01BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups01BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups01BypassEntry 1 }
|
|
|
|
ups01BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups01BypassEntry 2 }
|
|
|
|
ups01BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups01BypassEntry 3 }
|
|
|
|
ups01BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups01BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups01Alarm OBJECT IDENTIFIER ::= { ups01Objects 6 }
|
|
|
|
ups01AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups01Alarm 1 }
|
|
|
|
ups01AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups01AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups01AlarmId equal to 1, and increments the value of
|
|
ups01AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups01AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups01AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups01AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups01AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups01AlarmsPresent."
|
|
::= { ups01Alarm 2 }
|
|
|
|
ups01AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups01AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups01AlarmId }
|
|
::= { ups01AlarmTable 1 }
|
|
|
|
Ups01AlarmEntry ::= SEQUENCE {
|
|
ups01AlarmId PositiveInteger,
|
|
ups01AlarmDescr AutonomousType,
|
|
ups01AlarmTime TimeStamp
|
|
}
|
|
|
|
ups01AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups01AlarmEntry 1 }
|
|
|
|
ups01AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups01AlarmEntry 2 }
|
|
|
|
ups01AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups01AlarmTime shall equal
|
|
0."
|
|
::= { ups01AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups01WellKnownAlarms OBJECT IDENTIFIER ::= { ups01Alarm 3 }
|
|
ups01AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups01WellKnownAlarms 1 }
|
|
|
|
ups01AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups01WellKnownAlarms 2 }
|
|
|
|
ups01AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups01ConfigLowBattTime."
|
|
::= { ups01WellKnownAlarms 3 }
|
|
|
|
|
|
ups01AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups01WellKnownAlarms 4 }
|
|
|
|
ups01AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups01WellKnownAlarms 5 }
|
|
|
|
ups01AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups01WellKnownAlarms 6 }
|
|
|
|
ups01AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups01WellKnownAlarms 7 }
|
|
|
|
ups01AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups01WellKnownAlarms 8 }
|
|
|
|
ups01AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups01WellKnownAlarms 9 }
|
|
|
|
ups01AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups01WellKnownAlarms 10 }
|
|
|
|
ups01AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups01WellKnownAlarms 11 }
|
|
|
|
ups01AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups01WellKnownAlarms 12 }
|
|
|
|
ups01AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups01WellKnownAlarms 13 }
|
|
|
|
ups01AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups01WellKnownAlarms 14 }
|
|
|
|
ups01AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups01WellKnownAlarms 15 }
|
|
|
|
ups01AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups01WellKnownAlarms 16 }
|
|
|
|
ups01AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups01WellKnownAlarms 17 }
|
|
|
|
ups01AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups01WellKnownAlarms 18 }
|
|
|
|
ups01AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups01WellKnownAlarms 19 }
|
|
|
|
ups01AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups01WellKnownAlarms 20 }
|
|
|
|
ups01AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups01WellKnownAlarms 21 }
|
|
|
|
ups01AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups01ShutdownAfterDelay countdown is underway."
|
|
::= { ups01WellKnownAlarms 22 }
|
|
|
|
ups01AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups01WellKnownAlarms 23 }
|
|
|
|
ups01AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups01WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups01Test OBJECT IDENTIFIER ::= { ups01Objects 7 }
|
|
|
|
ups01TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups01TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups01TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups01TestId variable to
|
|
ups01TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups01TestNoTestsInitiated is returned."
|
|
::= { ups01Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups01TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (ups01TestSpinLock)
|
|
while (ups01TestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (ups01TestSpinLock)
|
|
}
|
|
lock_value = ups01TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (ups01TestSpinLock = lock_value, ups01TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (ups01TestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (ups01TestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups01TestResultsSummary */
|
|
get (ups01TestSpinLock, ups01TestResultsSummary,
|
|
ups01TestResultsDetail)
|
|
while (ups01TestResultsSummary == inProgress) {
|
|
short delay
|
|
get (ups01TestSpinLock, ups01TestResultsSummary,
|
|
ups01TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups01TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups01TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups01Test 2 }
|
|
|
|
ups01TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups01TestId to ups01TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups01Test 3 }
|
|
|
|
ups01TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups01TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups01Test 4 }
|
|
|
|
ups01TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups01TestResultsSummary is noTestsInitiated(6),
|
|
ups01TestStartTime has the value 0."
|
|
::= { ups01Test 5 }
|
|
|
|
ups01TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups01TestResultsSummary is noTestsInitiated(6),
|
|
ups01TestElapsedTime has the value 0."
|
|
::= { ups01Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups01WellKnownTests OBJECT IDENTIFIER ::= { ups01Test 7 }
|
|
|
|
|
|
ups01TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups01WellKnownTests 1 }
|
|
|
|
ups01TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups01WellKnownTests 2 }
|
|
|
|
ups01TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups01WellKnownTests 3 }
|
|
|
|
ups01TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups01WellKnownTests 4 }
|
|
|
|
ups01TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups01WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups01Control OBJECT IDENTIFIER ::= { ups01Objects 8 }
|
|
|
|
ups01ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups01ShutdownAfterDelay and ups01RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups01Control 1 }
|
|
|
|
ups01ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups01ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups01ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups01ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups01ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups01ShutdownAfterDelay already in effect."
|
|
::= { ups01Control 2 }
|
|
|
|
ups01StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups01StartupAfterDelay
|
|
countdown or ups01RebootWithDuration countdown in
|
|
progress. When read, ups01StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups01Control 3 }
|
|
|
|
ups01RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups01ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups01RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups01Control 4 }
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups01Traps OBJECT IDENTIFIER ::= { upsModule1 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups01TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups01EstimatedMinutesRemaining, ups01SecondsOnBattery,
|
|
ups01ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups01Traps 1 }
|
|
|
|
ups01TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups01TestId, ups01TestSpinLock,
|
|
ups01TestResultsSummary, ups01TestResultsDetail,
|
|
ups01TestStartTime, ups01TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups01Traps 2 }
|
|
|
|
ups01TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups01AlarmId, ups01AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups01AlarmOnBattery and
|
|
ups01AlarmTestInProgress."
|
|
::= { ups01Traps 3 }
|
|
|
|
ups01TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups01AlarmId, ups01AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups01AlarmTestInProgress."
|
|
::= { ups01Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups01Conformance OBJECT IDENTIFIER ::= { upsModule1 3 }
|
|
|
|
ups01Compliances OBJECT IDENTIFIER ::= { ups01Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups01SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups01SubsetIdentGroup,
|
|
ups01SubsetBatteryGroup, ups01SubsetInputGroup,
|
|
ups01SubsetOutputGroup, ups01SubsetAlarmGroup,
|
|
ups01SubsetControlGroup }
|
|
|
|
OBJECT ups01BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups01AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups01AlarmOnBattery, ups01AlarmLowBattery,
|
|
ups01AlarmInputBad, ups01AlarmUpsOutputOff,
|
|
ups01AlarmUpsSystemOff, and ups01AlarmTestInProgress."
|
|
|
|
OBJECT ups01OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups01ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups01Compliances 1 }
|
|
|
|
ups01BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups01BasicIdentGroup,
|
|
ups01BasicBatteryGroup, ups01BasicInputGroup,
|
|
ups01BasicOutputGroup, ups01BasicAlarmGroup,
|
|
ups01BasicTestGroup, ups01BasicControlGroup }
|
|
|
|
|
|
OBJECT ups01AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups01AlarmOnBattery, ups01AlarmLowBattery,
|
|
ups01AlarmDepletedBattery, ups01AlarmTempBad,
|
|
ups01AlarmInputBad, ups01AlarmOutputOverload,
|
|
ups01AlarmOnBypass, ups01AlarmBypassBad,
|
|
ups01AlarmOutputOffAsRequested,
|
|
ups01AlarmUpsOffAsRequested, ups01AlarmUpsOutputOff,
|
|
ups01AlarmUpsSystemOff, ups01AlarmGeneralFault,
|
|
ups01AlarmDiagnosticTestFailed,
|
|
ups01AlarmCommunicationsLost, ups01AlarmShutdownPending,
|
|
and ups01AlarmTestInProgress."
|
|
|
|
OBJECT ups01TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups01TestNoTestsInitiated."
|
|
|
|
OBJECT ups01OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups01BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups01BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups01ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups01Compliances 2 }
|
|
|
|
ups01FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups01FullIdentGroup, ups01FullBatteryGroup,
|
|
ups01FullInputGroup, ups01FullOutputGroup,
|
|
ups01FullAlarmGroup, ups01FullTestGroup,
|
|
ups01FullControlGroup }
|
|
|
|
OBJECT ups01AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups01AlarmBatteryBad, ups01AlarmOnBattery,
|
|
ups01AlarmLowBattery, ups01AlarmDepletedBattery,
|
|
ups01AlarmTempBad, ups01AlarmInputBad, ups01AlarmOnBypass,
|
|
ups01AlarmBypassBad, ups01AlarmOutputOffAsRequested,
|
|
ups01AlarmUpsOffAsRequested, ups01AlarmUpsOutputOff,
|
|
ups01AlarmUpsSystemOff, ups01AlarmGeneralFault,
|
|
ups01AlarmDiagnosticTestFailed,
|
|
ups01AlarmCommunicationsLost, ups01AlarmShutdownPending,
|
|
and ups01AlarmTestInProgress."
|
|
|
|
OBJECT ups01TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups01TestNoTestsInitiated,
|
|
ups01TestGeneralSystemsTest, and
|
|
ups01TestQuickBatteryTest."
|
|
|
|
OBJECT ups01OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups01FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups01FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups01ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups01Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--ups01IdentManufacturer x x x
|
|
--ups01IdentModel x x x
|
|
--ups01IdentUPSSoftwareVersion x x
|
|
--ups01IdentAgentSoftwareVersion x x x
|
|
--ups01IdentName x x x
|
|
--ups01IdentAttachedDevices x x
|
|
--
|
|
--ups01BatteryStatus x x x notes
|
|
--ups01SecondsOnBattery x x x
|
|
--ups01EstimatedMinutesRemaining x
|
|
--ups01EstimatedChargeRemaining x
|
|
--ups01BatteryVoltage
|
|
--ups01BatteryCurrent
|
|
--ups01BatteryTemperature
|
|
--
|
|
--ups01InputLineBads x x x
|
|
--ups01InputNumLines x x
|
|
--ups01InputFrequency x x
|
|
--ups01InputVoltage x x
|
|
--ups01InputCurrent
|
|
--ups01InputTruePower
|
|
--
|
|
--ups01OutputSource x x x notes
|
|
--ups01OutputFrequency x x
|
|
--ups01OutputNumLines x x
|
|
--ups01OutputVoltage x x
|
|
--ups01OutputCurrent x
|
|
--ups01OutputPower x
|
|
--ups01OutputPercentLoad x
|
|
--
|
|
--
|
|
--ups01BypassFrequency x x notes
|
|
--ups01BypassNumLines x x
|
|
--ups01BypassVoltage x x
|
|
--ups01BypassCurrent
|
|
--ups01BypassPower
|
|
--
|
|
--
|
|
--ups01AlarmsPresent x x x
|
|
--ups01AlarmDescr x x x notes
|
|
--ups01AlarmTime x x x
|
|
--
|
|
--ups01TestId x x notes
|
|
--ups01TestSpinLock x x
|
|
--ups01TestResultsSummary x x
|
|
--ups01TestResultsDetail x x
|
|
--ups01TestStartTime x x
|
|
--ups01TestElapsedTime x x
|
|
--
|
|
--ups01ShutdownType x x x notes
|
|
--ups01ShutdownAfterDelay x x x
|
|
--ups01StartupAfterDelay x x
|
|
--ups01RebootWithDuration x x
|
|
--
|
|
|
|
|
|
-- units of conformance
|
|
ups01Groups OBJECT IDENTIFIER ::= { ups01Conformance 2 }
|
|
|
|
ups01SubsetGroups OBJECT IDENTIFIER ::= { ups01Groups 1 }
|
|
|
|
ups01SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups01IdentManufacturer, ups01IdentModel,
|
|
ups01IdentAgentSoftwareVersion, ups01IdentName,
|
|
ups01IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups01SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups01SubsetGroups 1 }
|
|
|
|
ups01SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups01BatteryStatus, ups01SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups01SubsetGroups 2 }
|
|
|
|
ups01SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups01InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups01SubsetGroups 3 }
|
|
|
|
ups01SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups01OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups01SubsetGroups 4 }
|
|
|
|
|
|
-- { ups01SubsetGroups 5 } is reserved for
|
|
-- future use (ups01SubsetBypassGroup)
|
|
|
|
ups01SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups01AlarmsPresent, ups01AlarmDescr, ups01AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups01SubsetGroups 6 }
|
|
|
|
-- { ups01SubsetGroups 7 } is reserved for
|
|
-- future use (ups01SubsetTestGroup)
|
|
|
|
ups01SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups01ShutdownType, ups01ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups01SubsetGroups 8 }
|
|
|
|
ups01BasicGroups OBJECT IDENTIFIER ::= { ups01Groups 2 }
|
|
|
|
ups01BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups01IdentManufacturer, ups01IdentModel,
|
|
ups01IdentUPSSoftwareVersion,
|
|
ups01IdentAgentSoftwareVersion, ups01IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 1 }
|
|
|
|
ups01BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups01BatteryStatus, ups01SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 2 }
|
|
|
|
ups01BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups01InputLineBads, ups01InputNumLines,
|
|
ups01InputFrequency, ups01InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 3 }
|
|
|
|
ups01BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups01OutputSource, ups01OutputFrequency,
|
|
ups01OutputNumLines, ups01OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 4 }
|
|
|
|
ups01BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups01BypassFrequency, ups01BypassNumLines,
|
|
ups01BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 5 }
|
|
|
|
ups01BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups01AlarmsPresent, ups01AlarmDescr, ups01AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups01BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 6 }
|
|
|
|
ups01BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups01TestId, ups01TestSpinLock,
|
|
ups01TestResultsSummary, ups01TestResultsDetail,
|
|
ups01TestStartTime, ups01TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 7 }
|
|
|
|
ups01BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups01ShutdownType, ups01ShutdownAfterDelay,
|
|
ups01StartupAfterDelay, ups01RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups01BasicGroups 8 }
|
|
|
|
ups01FullGroups OBJECT IDENTIFIER ::= { ups01Groups 3 }
|
|
|
|
ups01FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups01IdentManufacturer, ups01IdentModel,
|
|
ups01IdentUPSSoftwareVersion,
|
|
ups01IdentAgentSoftwareVersion, ups01IdentName,
|
|
ups01IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups01FullGroups 1 }
|
|
|
|
ups01FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups01BatteryStatus, ups01SecondsOnBattery,
|
|
ups01EstimatedMinutesRemaining,
|
|
ups01EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 2 }
|
|
|
|
ups01FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups01InputLineBads, ups01InputNumLines,
|
|
ups01InputFrequency, ups01InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 3 }
|
|
|
|
ups01FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups01OutputSource, ups01OutputFrequency,
|
|
ups01OutputNumLines, ups01OutputVoltage,
|
|
ups01OutputCurrent, ups01OutputPower,
|
|
ups01OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 4 }
|
|
|
|
ups01FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups01BypassFrequency, ups01BypassNumLines,
|
|
ups01BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 5 }
|
|
|
|
ups01FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups01AlarmsPresent, ups01AlarmDescr, ups01AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups01FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 6 }
|
|
|
|
ups01FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups01TestId, ups01TestSpinLock,
|
|
ups01TestResultsSummary, ups01TestResultsDetail,
|
|
ups01TestStartTime, ups01TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 7 }
|
|
|
|
ups01FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups01ShutdownType, ups01ShutdownAfterDelay,
|
|
ups01StartupAfterDelay, ups01RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups01FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups01FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 2 data
|
|
--
|
|
|
|
upsModule2 OBJECT IDENTIFIER ::= { upsModular 3 }
|
|
|
|
ups02Objects OBJECT IDENTIFIER ::= { upsModule2 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for upsIdentName and
|
|
-- upsIdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups02Ident OBJECT IDENTIFIER ::= { ups02Objects 1 }
|
|
|
|
ups02IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups02Ident 1 }
|
|
|
|
ups02IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups02Ident 2 }
|
|
|
|
ups02IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
upsIdentAgentSoftwareVersion in some implementations."
|
|
::= { ups02Ident 3 }
|
|
|
|
ups02IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
upsIdentUPSSoftwareVersion in some implementations."
|
|
::= { ups02Ident 4 }
|
|
|
|
ups02IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups02Ident 5 }
|
|
|
|
ups02IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups02Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups02Battery OBJECT IDENTIFIER ::= { ups02Objects 2 }
|
|
|
|
ups02BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
upsConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to upsConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups02Battery 1 }
|
|
|
|
ups02SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups02Battery 2 }
|
|
|
|
ups02EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups02Battery 3 }
|
|
|
|
ups02EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups02Battery 4 }
|
|
|
|
ups02BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups02Battery 5 }
|
|
|
|
ups02BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups02Battery 6 }
|
|
|
|
ups02BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups02Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups02Input OBJECT IDENTIFIER ::= { ups02Objects 3 }
|
|
|
|
ups02InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups02Input 1 }
|
|
|
|
|
|
ups02InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups02Input 2 }
|
|
|
|
ups02InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups02InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of upsInputNumLines."
|
|
::= { ups02Input 3 }
|
|
|
|
ups02InputEntry OBJECT-TYPE
|
|
SYNTAX Ups02InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups02InputLineIndex }
|
|
::= { ups02InputTable 1 }
|
|
|
|
Ups02InputEntry ::= SEQUENCE {
|
|
ups02InputLineIndex PositiveInteger,
|
|
ups02InputFrequency NonNegativeInteger,
|
|
ups02InputVoltage NonNegativeInteger,
|
|
ups02InputCurrent NonNegativeInteger,
|
|
ups02InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups02InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups02InputEntry 1 }
|
|
|
|
ups02InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups02InputEntry 2 }
|
|
|
|
ups02InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups02InputEntry 3 }
|
|
|
|
ups02InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups02InputEntry 4 }
|
|
|
|
ups02InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups02InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups02Output OBJECT IDENTIFIER ::= { ups02Objects 4 }
|
|
|
|
ups02OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups02Output 1 }
|
|
|
|
ups02OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups02Output 2 }
|
|
|
|
ups02OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups02Output 3 }
|
|
|
|
ups02OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups02OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups02OutputNumLines."
|
|
::= { ups02Output 4 }
|
|
|
|
ups02OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups02OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups02OutputLineIndex }
|
|
::= { ups02OutputTable 1 }
|
|
|
|
Ups02OutputEntry ::= SEQUENCE {
|
|
ups02OutputLineIndex PositiveInteger,
|
|
ups02OutputVoltage NonNegativeInteger,
|
|
ups02OutputCurrent NonNegativeInteger,
|
|
ups02OutputPower NonNegativeInteger,
|
|
ups02OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups02OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups02OutputEntry 1 }
|
|
|
|
ups02OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups02OutputEntry 2 }
|
|
|
|
ups02OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups02OutputEntry 3 }
|
|
|
|
ups02OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups02OutputEntry 4 }
|
|
|
|
ups02OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups02OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups02Bypass OBJECT IDENTIFIER ::= { ups02Objects 5 }
|
|
|
|
ups02BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups02Bypass 1 }
|
|
|
|
ups02BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups02Bypass 2 }
|
|
|
|
ups02BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups02BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups02BypassNumLines."
|
|
::= { ups02Bypass 3 }
|
|
|
|
ups02BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups02BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups02BypassLineIndex }
|
|
::= { ups02BypassTable 1 }
|
|
|
|
Ups02BypassEntry ::= SEQUENCE {
|
|
ups02BypassLineIndex PositiveInteger,
|
|
ups02BypassVoltage NonNegativeInteger,
|
|
ups02BypassCurrent NonNegativeInteger,
|
|
ups02BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups02BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups02BypassEntry 1 }
|
|
|
|
ups02BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups02BypassEntry 2 }
|
|
|
|
ups02BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups02BypassEntry 3 }
|
|
|
|
ups02BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups02BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups02Alarm OBJECT IDENTIFIER ::= { ups02Objects 6 }
|
|
|
|
ups02AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups02Alarm 1 }
|
|
|
|
ups02AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups02AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups02AlarmId equal to 1, and increments the value of
|
|
ups02AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups02AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups02AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups02AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups02AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups02AlarmsPresent."
|
|
::= { ups02Alarm 2 }
|
|
|
|
ups02AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups02AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups02AlarmId }
|
|
::= { ups02AlarmTable 1 }
|
|
|
|
Ups02AlarmEntry ::= SEQUENCE {
|
|
ups02AlarmId PositiveInteger,
|
|
ups02AlarmDescr AutonomousType,
|
|
ups02AlarmTime TimeStamp
|
|
}
|
|
|
|
ups02AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups02AlarmEntry 1 }
|
|
|
|
ups02AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups02AlarmEntry 2 }
|
|
|
|
ups02AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups02AlarmTime shall equal
|
|
0."
|
|
::= { ups02AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups02WellKnownAlarms OBJECT IDENTIFIER ::= { ups02Alarm 3 }
|
|
ups02AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups02WellKnownAlarms 1 }
|
|
|
|
ups02AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups02WellKnownAlarms 2 }
|
|
|
|
ups02AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups02ConfigLowBattTime."
|
|
::= { ups02WellKnownAlarms 3 }
|
|
|
|
|
|
ups02AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups02WellKnownAlarms 4 }
|
|
|
|
ups02AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups02WellKnownAlarms 5 }
|
|
|
|
ups02AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups02WellKnownAlarms 6 }
|
|
|
|
ups02AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups02WellKnownAlarms 7 }
|
|
|
|
ups02AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups02WellKnownAlarms 8 }
|
|
|
|
ups02AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups02WellKnownAlarms 9 }
|
|
|
|
ups02AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups02WellKnownAlarms 10 }
|
|
|
|
ups02AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups02WellKnownAlarms 11 }
|
|
|
|
ups02AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups02WellKnownAlarms 12 }
|
|
|
|
ups02AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups02WellKnownAlarms 13 }
|
|
|
|
ups02AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups02WellKnownAlarms 14 }
|
|
|
|
ups02AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups02WellKnownAlarms 15 }
|
|
|
|
ups02AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups02WellKnownAlarms 16 }
|
|
|
|
ups02AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups02WellKnownAlarms 17 }
|
|
|
|
ups02AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups02WellKnownAlarms 18 }
|
|
|
|
ups02AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups02WellKnownAlarms 19 }
|
|
|
|
ups02AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups02WellKnownAlarms 20 }
|
|
|
|
ups02AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups02WellKnownAlarms 21 }
|
|
|
|
ups02AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A upsShutdownAfterDelay countdown is underway."
|
|
::= { ups02WellKnownAlarms 22 }
|
|
|
|
ups02AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups02WellKnownAlarms 23 }
|
|
|
|
ups02AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups02WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups02Test OBJECT IDENTIFIER ::= { ups02Objects 7 }
|
|
|
|
ups02TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups02TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups02TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups02TestId variable to
|
|
ups02TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups02TestNoTestsInitiated is returned."
|
|
::= { ups02Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups02TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (ups02TestSpinLock)
|
|
while (ups02TestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (ups02TestSpinLock)
|
|
}
|
|
lock_value = ups02TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (ups02TestSpinLock = lock_value, upsTestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (ups02TestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (ups02TestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups02TestResultsSummary */
|
|
get (ups02TestSpinLock, ups02TestResultsSummary,
|
|
ups02TestResultsDetail)
|
|
while (ups02TestResultsSummary == inProgress) {
|
|
short delay
|
|
get (ups02TestSpinLock, ups02TestResultsSummary,
|
|
ups02TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups02TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups02TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups02Test 2 }
|
|
|
|
ups02TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups02TestId to ups02TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups02Test 3 }
|
|
|
|
ups02TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups02TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups02Test 4 }
|
|
|
|
ups02TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups02TestResultsSummary is noTestsInitiated(6),
|
|
ups02TestStartTime has the value 0."
|
|
::= { ups02Test 5 }
|
|
|
|
ups02TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups02TestResultsSummary is noTestsInitiated(6),
|
|
ups02TestElapsedTime has the value 0."
|
|
::= { ups02Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups02WellKnownTests OBJECT IDENTIFIER ::= { ups02Test 7 }
|
|
|
|
|
|
ups02TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups02WellKnownTests 1 }
|
|
|
|
ups02TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups02WellKnownTests 2 }
|
|
|
|
ups02TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups02WellKnownTests 3 }
|
|
|
|
ups02TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups02WellKnownTests 4 }
|
|
|
|
ups02TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups02WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups02Control OBJECT IDENTIFIER ::= { ups02Objects 8 }
|
|
|
|
ups02ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups02ShutdownAfterDelay and ups02RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups02Control 1 }
|
|
|
|
ups02ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups02ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups02ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups02ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups02ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups02ShutdownAfterDelay already in effect."
|
|
::= { ups02Control 2 }
|
|
|
|
ups02StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups02StartupAfterDelay
|
|
countdown or ups02RebootWithDuration countdown in
|
|
progress. When read, ups02StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups02Control 3 }
|
|
|
|
ups02RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups02ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups02RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups02Control 4 }
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups02Traps OBJECT IDENTIFIER ::= { upsModule2 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups02TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups02EstimatedMinutesRemaining, ups02SecondsOnBattery,
|
|
ups02ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups02Traps 1 }
|
|
|
|
ups02TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups02TestId, ups02TestSpinLock,
|
|
ups02TestResultsSummary, ups02TestResultsDetail,
|
|
ups02TestStartTime, ups02TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups02Traps 2 }
|
|
|
|
ups02TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups02AlarmId, ups02AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups02AlarmOnBattery and
|
|
upsAlarmTestInProgress."
|
|
::= { ups02Traps 3 }
|
|
|
|
ups02TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups02AlarmId, ups02AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups02AlarmTestInProgress."
|
|
::= { ups02Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups02Conformance OBJECT IDENTIFIER ::= { upsModule2 3 }
|
|
|
|
ups02Compliances OBJECT IDENTIFIER ::= { ups02Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups02SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups02SubsetIdentGroup,
|
|
ups02SubsetBatteryGroup, ups02SubsetInputGroup,
|
|
ups02SubsetOutputGroup, ups02SubsetAlarmGroup,
|
|
ups02SubsetControlGroup }
|
|
|
|
OBJECT ups02BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups02AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups02AlarmOnBattery, ups02AlarmLowBattery,
|
|
ups02AlarmInputBad, ups02AlarmUpsOutputOff,
|
|
ups02AlarmUpsSystemOff, and ups02AlarmTestInProgress."
|
|
|
|
OBJECT ups02OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups02ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups02Compliances 1 }
|
|
|
|
ups02BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups02BasicIdentGroup,
|
|
ups02BasicBatteryGroup, ups02BasicInputGroup,
|
|
ups02BasicOutputGroup, ups02BasicAlarmGroup,
|
|
ups02BasicTestGroup, ups02BasicControlGroup }
|
|
|
|
|
|
OBJECT ups02AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups02AlarmOnBattery, ups02AlarmLowBattery,
|
|
ups02AlarmDepletedBattery, ups02AlarmTempBad,
|
|
ups02AlarmInputBad, ups02AlarmOutputOverload,
|
|
ups02AlarmOnBypass, ups02AlarmBypassBad,
|
|
ups02AlarmOutputOffAsRequested,
|
|
ups02AlarmUpsOffAsRequested, ups02AlarmUpsOutputOff,
|
|
ups02AlarmUpsSystemOff, ups02AlarmGeneralFault,
|
|
ups02AlarmDiagnosticTestFailed,
|
|
ups02AlarmCommunicationsLost, ups02AlarmShutdownPending,
|
|
and ups02AlarmTestInProgress."
|
|
|
|
OBJECT ups02TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups02TestNoTestsInitiated."
|
|
|
|
OBJECT ups02OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups02BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups02BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups02ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups02Compliances 2 }
|
|
|
|
ups02FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups02FullIdentGroup, ups02FullBatteryGroup,
|
|
ups02FullInputGroup, ups02FullOutputGroup,
|
|
ups02FullAlarmGroup, ups02FullTestGroup,
|
|
ups02FullControlGroup }
|
|
|
|
OBJECT ups02AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups02AlarmBatteryBad, ups02AlarmOnBattery,
|
|
ups02AlarmLowBattery, ups02AlarmDepletedBattery,
|
|
ups02AlarmTempBad, ups02AlarmInputBad, ups02AlarmOnBypass,
|
|
ups02AlarmBypassBad, ups02AlarmOutputOffAsRequested,
|
|
ups02AlarmUpsOffAsRequested, ups02AlarmUpsOutputOff,
|
|
ups02AlarmUpsSystemOff, ups02AlarmGeneralFault,
|
|
ups02AlarmDiagnosticTestFailed,
|
|
ups02AlarmCommunicationsLost, ups02AlarmShutdownPending,
|
|
and ups02AlarmTestInProgress."
|
|
|
|
OBJECT ups02TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups02TestNoTestsInitiated,
|
|
ups02TestGeneralSystemsTest, and
|
|
ups02TestQuickBatteryTest."
|
|
|
|
OBJECT ups02OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups02FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups02FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups02ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups02Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups02Groups OBJECT IDENTIFIER ::= { ups02Conformance 2 }
|
|
|
|
ups02SubsetGroups OBJECT IDENTIFIER ::= { ups02Groups 1 }
|
|
|
|
ups02SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups02IdentManufacturer, ups02IdentModel,
|
|
ups02IdentAgentSoftwareVersion, ups02IdentName,
|
|
ups02IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups02SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups02SubsetGroups 1 }
|
|
|
|
ups02SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups02BatteryStatus, ups02SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups02SubsetGroups 2 }
|
|
|
|
ups02SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups02InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups02SubsetGroups 3 }
|
|
|
|
ups02SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups02OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups02SubsetGroups 4 }
|
|
|
|
|
|
-- { ups02SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups02SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups02AlarmsPresent, ups02AlarmDescr, ups02AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups02SubsetGroups 6 }
|
|
|
|
-- { ups02SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups02SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups02ShutdownType, ups02ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups02SubsetGroups 8 }
|
|
|
|
ups02BasicGroups OBJECT IDENTIFIER ::= { ups02Groups 2 }
|
|
|
|
ups02BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups02IdentManufacturer, ups02IdentModel,
|
|
ups02IdentUPSSoftwareVersion,
|
|
ups02IdentAgentSoftwareVersion, ups02IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 1 }
|
|
|
|
ups02BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups02BatteryStatus, ups02SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 2 }
|
|
|
|
ups02BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups02InputLineBads, ups02InputNumLines,
|
|
ups02InputFrequency, ups02InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 3 }
|
|
|
|
ups02BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups02OutputSource, ups02OutputFrequency,
|
|
ups02OutputNumLines, ups02OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 4 }
|
|
|
|
ups02BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups02BypassFrequency, ups02BypassNumLines,
|
|
ups02BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 5 }
|
|
|
|
ups02BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups02AlarmsPresent, ups02AlarmDescr, ups02AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups02BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 6 }
|
|
|
|
ups02BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups02TestId, ups02TestSpinLock,
|
|
ups02TestResultsSummary, ups02TestResultsDetail,
|
|
ups02TestStartTime, ups02TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 7 }
|
|
|
|
ups02BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups02ShutdownType, ups02ShutdownAfterDelay,
|
|
ups02StartupAfterDelay, ups02RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups02BasicGroups 8 }
|
|
|
|
ups02FullGroups OBJECT IDENTIFIER ::= { ups02Groups 3 }
|
|
|
|
ups02FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups02IdentManufacturer, ups02IdentModel,
|
|
ups02IdentUPSSoftwareVersion,
|
|
ups02IdentAgentSoftwareVersion, ups02IdentName,
|
|
ups02IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups02FullGroups 1 }
|
|
|
|
ups02FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups02BatteryStatus, ups02SecondsOnBattery,
|
|
ups02EstimatedMinutesRemaining,
|
|
ups02EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 2 }
|
|
|
|
ups02FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups02InputLineBads, ups02InputNumLines,
|
|
ups02InputFrequency, ups02InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 3 }
|
|
|
|
ups02FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups02OutputSource, ups02OutputFrequency,
|
|
ups02OutputNumLines, ups02OutputVoltage,
|
|
ups02OutputCurrent, ups02OutputPower,
|
|
ups02OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 4 }
|
|
|
|
ups02FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups02BypassFrequency, ups02BypassNumLines,
|
|
ups02BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 5 }
|
|
|
|
ups02FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups02AlarmsPresent, ups02AlarmDescr, ups02AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups02FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 6 }
|
|
|
|
ups02FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups02TestId, ups02TestSpinLock,
|
|
ups02TestResultsSummary, ups02TestResultsDetail,
|
|
ups02TestStartTime, ups02TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 7 }
|
|
|
|
ups02FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups02ShutdownType, ups02ShutdownAfterDelay,
|
|
ups02StartupAfterDelay, ups02RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups02FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups02FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 3 data
|
|
--
|
|
|
|
upsModule3 OBJECT IDENTIFIER ::= { upsModular 4 }
|
|
ups03Objects OBJECT IDENTIFIER ::= { upsModule3 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for upsIdentName and
|
|
-- upsIdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups03Ident OBJECT IDENTIFIER ::= { ups03Objects 1 }
|
|
|
|
ups03IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups03Ident 1 }
|
|
|
|
ups03IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups03Ident 2 }
|
|
|
|
ups03IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups03IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups03Ident 3 }
|
|
|
|
ups03IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups03IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups03Ident 4 }
|
|
|
|
ups03IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups03Ident 5 }
|
|
|
|
ups03IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups03Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups03Battery OBJECT IDENTIFIER ::= { ups03Objects 2 }
|
|
|
|
ups03BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups03ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups03ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups03Battery 1 }
|
|
|
|
ups03SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups03Battery 2 }
|
|
|
|
ups03EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups03Battery 3 }
|
|
|
|
ups03EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups03Battery 4 }
|
|
|
|
ups03BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups03Battery 5 }
|
|
|
|
ups03BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups03Battery 6 }
|
|
|
|
ups03BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups03Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups03Input OBJECT IDENTIFIER ::= { ups03Objects 3 }
|
|
|
|
ups03InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups03Input 1 }
|
|
|
|
|
|
ups03InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups03Input 2 }
|
|
|
|
ups03InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups03InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups03InputNumLines."
|
|
::= { ups03Input 3 }
|
|
|
|
ups03InputEntry OBJECT-TYPE
|
|
SYNTAX Ups03InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups03InputLineIndex }
|
|
::= { ups03InputTable 1 }
|
|
|
|
Ups03InputEntry ::= SEQUENCE {
|
|
ups03InputLineIndex PositiveInteger,
|
|
ups03InputFrequency NonNegativeInteger,
|
|
ups03InputVoltage NonNegativeInteger,
|
|
ups03InputCurrent NonNegativeInteger,
|
|
ups03InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups03InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups03InputEntry 1 }
|
|
|
|
ups03InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups03InputEntry 2 }
|
|
|
|
ups03InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups03InputEntry 3 }
|
|
|
|
ups03InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups03InputEntry 4 }
|
|
|
|
ups03InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups03InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups03Output OBJECT IDENTIFIER ::= { ups03Objects 4 }
|
|
|
|
ups03OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups03Output 1 }
|
|
|
|
ups03OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups03Output 2 }
|
|
|
|
ups03OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups03Output 3 }
|
|
|
|
ups03OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups03OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups03OutputNumLines."
|
|
::= { ups03Output 4 }
|
|
|
|
ups03OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups03OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups03OutputLineIndex }
|
|
::= { ups03OutputTable 1 }
|
|
|
|
Ups03OutputEntry ::= SEQUENCE {
|
|
ups03OutputLineIndex PositiveInteger,
|
|
ups03OutputVoltage NonNegativeInteger,
|
|
ups03OutputCurrent NonNegativeInteger,
|
|
ups03OutputPower NonNegativeInteger,
|
|
ups03OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups03OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups03OutputEntry 1 }
|
|
|
|
ups03OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups03OutputEntry 2 }
|
|
|
|
ups03OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups03OutputEntry 3 }
|
|
|
|
ups03OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups03OutputEntry 4 }
|
|
|
|
ups03OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups03OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups03Bypass OBJECT IDENTIFIER ::= { ups03Objects 5 }
|
|
|
|
ups03BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups03Bypass 1 }
|
|
|
|
ups03BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups03Bypass 2 }
|
|
|
|
ups03BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups03BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups03BypassNumLines."
|
|
::= { ups03Bypass 3 }
|
|
|
|
ups03BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups03BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups03BypassLineIndex }
|
|
::= { ups03BypassTable 1 }
|
|
|
|
Ups03BypassEntry ::= SEQUENCE {
|
|
ups03BypassLineIndex PositiveInteger,
|
|
ups03BypassVoltage NonNegativeInteger,
|
|
ups03BypassCurrent NonNegativeInteger,
|
|
ups03BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups03BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups03BypassEntry 1 }
|
|
|
|
ups03BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups03BypassEntry 2 }
|
|
|
|
ups03BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups03BypassEntry 3 }
|
|
|
|
ups03BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups03BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups03Alarm OBJECT IDENTIFIER ::= { ups03Objects 6 }
|
|
|
|
ups03AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups03Alarm 1 }
|
|
|
|
ups03AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups03AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups03AlarmId equal to 1, and increments the value of
|
|
ups03AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups03AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups03AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups03AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups03AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups03AlarmsPresent."
|
|
::= { ups03Alarm 2 }
|
|
|
|
ups03AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups03AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups03AlarmId }
|
|
::= { ups03AlarmTable 1 }
|
|
|
|
Ups03AlarmEntry ::= SEQUENCE {
|
|
ups03AlarmId PositiveInteger,
|
|
ups03AlarmDescr AutonomousType,
|
|
ups03AlarmTime TimeStamp
|
|
}
|
|
|
|
ups03AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups03AlarmEntry 1 }
|
|
|
|
ups03AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups03AlarmEntry 2 }
|
|
|
|
ups03AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups03AlarmTime shall equal
|
|
0."
|
|
::= { ups03AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups03WellKnownAlarms OBJECT IDENTIFIER ::= { ups03Alarm 3 }
|
|
ups03AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups03WellKnownAlarms 1 }
|
|
|
|
ups03AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups03WellKnownAlarms 2 }
|
|
|
|
ups03AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups03ConfigLowBattTime."
|
|
::= { ups03WellKnownAlarms 3 }
|
|
|
|
|
|
ups03AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups03WellKnownAlarms 4 }
|
|
|
|
ups03AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups03WellKnownAlarms 5 }
|
|
|
|
ups03AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups03WellKnownAlarms 6 }
|
|
|
|
ups03AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups03WellKnownAlarms 7 }
|
|
|
|
ups03AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups03WellKnownAlarms 8 }
|
|
|
|
ups03AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups03WellKnownAlarms 9 }
|
|
|
|
ups03AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups03WellKnownAlarms 10 }
|
|
|
|
ups03AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups03WellKnownAlarms 11 }
|
|
|
|
ups03AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups03WellKnownAlarms 12 }
|
|
|
|
ups03AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups03WellKnownAlarms 13 }
|
|
|
|
ups03AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups03WellKnownAlarms 14 }
|
|
|
|
ups03AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups03WellKnownAlarms 15 }
|
|
|
|
ups03AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups03WellKnownAlarms 16 }
|
|
|
|
ups03AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups03WellKnownAlarms 17 }
|
|
|
|
ups03AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups03WellKnownAlarms 18 }
|
|
|
|
ups03AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups03WellKnownAlarms 19 }
|
|
|
|
ups03AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups03WellKnownAlarms 20 }
|
|
|
|
ups03AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups03WellKnownAlarms 21 }
|
|
|
|
ups03AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups03ShutdownAfterDelay countdown is underway."
|
|
::= { ups03WellKnownAlarms 22 }
|
|
|
|
ups03AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups03WellKnownAlarms 23 }
|
|
|
|
ups03AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups03WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups03Test OBJECT IDENTIFIER ::= { ups03Objects 7 }
|
|
|
|
ups03TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups03TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups03TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups03TestId variable to
|
|
ups03TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups03TestNoTestsInitiated is returned."
|
|
::= { ups03Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups03TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups03TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups03TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups03TestResultsSummary */
|
|
get (upsTestSpinLock, ups03TestResultsSummary,
|
|
ups03TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups03TestResultsSummary,
|
|
ups03TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups03TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups03TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups03Test 2 }
|
|
|
|
ups03TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups03TestId to upsTestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups03Test 3 }
|
|
|
|
ups03TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups03TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups03Test 4 }
|
|
|
|
ups03TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups03TestResultsSummary is noTestsInitiated(6),
|
|
ups03TestStartTime has the value 0."
|
|
::= { ups03Test 5 }
|
|
|
|
ups03TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups03TestResultsSummary is noTestsInitiated(6),
|
|
ups03TestElapsedTime has the value 0."
|
|
::= { ups03Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups03WellKnownTests OBJECT IDENTIFIER ::= { ups03Test 7 }
|
|
|
|
|
|
ups03TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups03WellKnownTests 1 }
|
|
|
|
ups03TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups03WellKnownTests 2 }
|
|
|
|
ups03TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups03WellKnownTests 3 }
|
|
|
|
ups03TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups03WellKnownTests 4 }
|
|
|
|
ups03TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups03WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups03Control OBJECT IDENTIFIER ::= { ups03Objects 8 }
|
|
|
|
ups03ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups03ShutdownAfterDelay and upsRebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups03Control 1 }
|
|
|
|
ups03ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups03ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups03ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups03ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups03ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups03ShutdownAfterDelay already in effect."
|
|
::= { ups03Control 2 }
|
|
|
|
ups03StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups03StartupAfterDelay
|
|
countdown or ups03RebootWithDuration countdown in
|
|
progress. When read, ups03StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups03Control 3 }
|
|
|
|
ups03RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups03ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups03RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups03Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups03Traps OBJECT IDENTIFIER ::= { upsModule3 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups03TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups03EstimatedMinutesRemaining, upsSecondsOnBattery,
|
|
ups03ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups03Traps 1 }
|
|
|
|
ups03TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups03TestId, upsTestSpinLock,
|
|
ups03TestResultsSummary, upsTestResultsDetail,
|
|
ups03TestStartTime, ups03TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups03Traps 2 }
|
|
|
|
ups03TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups03AlarmId, ups03AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups03AlarmOnBattery and
|
|
ups03AlarmTestInProgress."
|
|
::= { ups03Traps 3 }
|
|
|
|
ups03TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups03AlarmId, ups03AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups03AlarmTestInProgress."
|
|
::= { ups03Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups03Conformance OBJECT IDENTIFIER ::= { upsModule3 3 }
|
|
|
|
ups03Compliances OBJECT IDENTIFIER ::= { ups03Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups03SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups03SubsetIdentGroup,
|
|
ups03SubsetBatteryGroup, ups03SubsetInputGroup,
|
|
ups03SubsetOutputGroup, ups03SubsetAlarmGroup,
|
|
ups03SubsetControlGroup }
|
|
|
|
OBJECT ups03BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups03AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups03AlarmOnBattery, ups03AlarmLowBattery,
|
|
ups03AlarmInputBad, ups03AlarmUpsOutputOff,
|
|
ups03AlarmUpsSystemOff, and ups03AlarmTestInProgress."
|
|
|
|
OBJECT ups03OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups03ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups03Compliances 1 }
|
|
|
|
ups03BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups03BasicIdentGroup,
|
|
ups03BasicBatteryGroup, ups03BasicInputGroup,
|
|
ups03BasicOutputGroup, ups03BasicAlarmGroup,
|
|
ups03BasicTestGroup, ups03BasicControlGroup }
|
|
|
|
|
|
OBJECT ups03AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups03AlarmOnBattery, ups03AlarmLowBattery,
|
|
ups03AlarmDepletedBattery, ups03AlarmTempBad,
|
|
ups03AlarmInputBad, ups03AlarmOutputOverload,
|
|
ups03AlarmOnBypass, ups03AlarmBypassBad,
|
|
ups03AlarmOutputOffAsRequested,
|
|
ups03AlarmUpsOffAsRequested, ups03AlarmUpsOutputOff,
|
|
ups03AlarmUpsSystemOff, ups03AlarmGeneralFault,
|
|
ups03AlarmDiagnosticTestFailed,
|
|
ups03AlarmCommunicationsLost, ups03AlarmShutdownPending,
|
|
and ups03AlarmTestInProgress."
|
|
|
|
OBJECT ups03TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups03TestNoTestsInitiated."
|
|
|
|
OBJECT ups03OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups03BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups03BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups03ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups03Compliances 2 }
|
|
|
|
ups03FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups03FullIdentGroup, upsFullBatteryGroup,
|
|
ups03FullInputGroup, upsFullOutputGroup,
|
|
ups03FullAlarmGroup, upsFullTestGroup,
|
|
ups03FullControlGroup }
|
|
|
|
OBJECT ups03AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups03AlarmBatteryBad, ups03AlarmOnBattery,
|
|
ups03AlarmLowBattery, ups03AlarmDepletedBattery,
|
|
ups03AlarmTempBad, ups03AlarmInputBad, upsAlarmOnBypass,
|
|
ups03AlarmBypassBad, ups03AlarmOutputOffAsRequested,
|
|
ups03AlarmUpsOffAsRequested, ups03AlarmUpsOutputOff,
|
|
ups03AlarmUpsSystemOff, ups03AlarmGeneralFault,
|
|
ups03AlarmDiagnosticTestFailed,
|
|
ups03AlarmCommunicationsLost, ups03AlarmShutdownPending,
|
|
and ups03AlarmTestInProgress."
|
|
|
|
OBJECT ups03TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups03TestNoTestsInitiated,
|
|
ups03TestGeneralSystemsTest, and
|
|
ups03TestQuickBatteryTest."
|
|
|
|
OBJECT ups03OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups03FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups03FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups03ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups03Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups03Groups OBJECT IDENTIFIER ::= { ups03Conformance 2 }
|
|
|
|
ups03SubsetGroups OBJECT IDENTIFIER ::= { ups03Groups 1 }
|
|
|
|
ups03SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups03IdentManufacturer, ups03IdentModel,
|
|
ups03IdentAgentSoftwareVersion, ups03IdentName,
|
|
ups03IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups03SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups03SubsetGroups 1 }
|
|
|
|
ups03SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups03BatteryStatus, ups03SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups03SubsetGroups 2 }
|
|
|
|
ups03SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups03InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups03SubsetGroups 3 }
|
|
|
|
ups03SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups03OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups03SubsetGroups 4 }
|
|
|
|
|
|
-- { ups03SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups03SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups03AlarmsPresent, ups03AlarmDescr, ups03AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups03SubsetGroups 6 }
|
|
|
|
-- { ups03SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups03SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups03ShutdownType, ups03ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups03SubsetGroups 8 }
|
|
|
|
ups03BasicGroups OBJECT IDENTIFIER ::= { ups03Groups 2 }
|
|
|
|
ups03BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups03IdentManufacturer, ups03IdentModel,
|
|
ups03IdentUPSSoftwareVersion,
|
|
ups03IdentAgentSoftwareVersion, ups03IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 1 }
|
|
|
|
ups03BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups03BatteryStatus, ups03SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 2 }
|
|
|
|
ups03BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups03InputLineBads, ups03InputNumLines,
|
|
ups03InputFrequency, ups03InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 3 }
|
|
|
|
ups03BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups03OutputSource, ups03OutputFrequency,
|
|
ups03OutputNumLines, ups03OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 4 }
|
|
|
|
ups03BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups03BypassFrequency, ups03BypassNumLines,
|
|
ups03BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 5 }
|
|
|
|
ups03BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups03AlarmsPresent, ups03AlarmDescr, ups03AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups03BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 6 }
|
|
|
|
ups03BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups03TestId, ups03TestSpinLock,
|
|
ups03TestResultsSummary, ups03TestResultsDetail,
|
|
ups03TestStartTime, ups03TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 7 }
|
|
|
|
ups03BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups03ShutdownType, ups03ShutdownAfterDelay,
|
|
ups03StartupAfterDelay, ups03RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups03BasicGroups 8 }
|
|
|
|
ups03FullGroups OBJECT IDENTIFIER ::= { ups03Groups 3 }
|
|
|
|
ups03FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups03IdentManufacturer, ups03IdentModel,
|
|
ups03IdentUPSSoftwareVersion,
|
|
ups03IdentAgentSoftwareVersion, ups03IdentName,
|
|
ups03IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups03FullGroups 1 }
|
|
|
|
ups03FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups03BatteryStatus, ups03SecondsOnBattery,
|
|
ups03EstimatedMinutesRemaining,
|
|
ups03EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 2 }
|
|
|
|
ups03FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups03InputLineBads, ups03InputNumLines,
|
|
ups03InputFrequency, ups03InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 3 }
|
|
|
|
ups03FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups03OutputSource, ups03OutputFrequency,
|
|
ups03OutputNumLines, ups03OutputVoltage,
|
|
ups03OutputCurrent, ups03OutputPower,
|
|
ups03OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 4 }
|
|
|
|
ups03FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups03BypassFrequency, ups03BypassNumLines,
|
|
ups03BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 5 }
|
|
|
|
ups03FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups03AlarmsPresent, ups03AlarmDescr, ups03AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups03FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 6 }
|
|
|
|
ups03FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups03TestId, ups03TestSpinLock,
|
|
ups03TestResultsSummary, ups03TestResultsDetail,
|
|
ups03TestStartTime, ups03TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 7 }
|
|
|
|
ups03FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups03ShutdownType, ups03ShutdownAfterDelay,
|
|
ups03StartupAfterDelay, ups03RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups03FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups03FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 4 data
|
|
--
|
|
|
|
upsModule4 OBJECT IDENTIFIER ::= { upsModular 5 }
|
|
ups04Objects OBJECT IDENTIFIER ::= { upsModule4 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups04IdentName and
|
|
-- ups04IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups04Ident OBJECT IDENTIFIER ::= { ups04Objects 1 }
|
|
|
|
ups04IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups04Ident 1 }
|
|
|
|
ups04IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups04Ident 2 }
|
|
|
|
ups04IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups04IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups04Ident 3 }
|
|
|
|
ups04IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups04IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups04Ident 4 }
|
|
|
|
ups04IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups04Ident 5 }
|
|
|
|
ups04IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups04Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups04Battery OBJECT IDENTIFIER ::= { ups04Objects 2 }
|
|
|
|
ups04BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups04ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups04ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups04Battery 1 }
|
|
|
|
ups04SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups04Battery 2 }
|
|
|
|
ups04EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups04Battery 3 }
|
|
|
|
ups04EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups04Battery 4 }
|
|
|
|
ups04BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups04Battery 5 }
|
|
|
|
ups04BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups04Battery 6 }
|
|
|
|
ups04BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups04Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups04Input OBJECT IDENTIFIER ::= { ups04Objects 3 }
|
|
|
|
ups04InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups04Input 1 }
|
|
|
|
|
|
ups04InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups04Input 2 }
|
|
|
|
ups04InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups04InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups04InputNumLines."
|
|
::= { ups04Input 3 }
|
|
|
|
ups04InputEntry OBJECT-TYPE
|
|
SYNTAX Ups04InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups04InputLineIndex }
|
|
::= { ups04InputTable 1 }
|
|
|
|
Ups04InputEntry ::= SEQUENCE {
|
|
ups04InputLineIndex PositiveInteger,
|
|
ups04InputFrequency NonNegativeInteger,
|
|
ups04InputVoltage NonNegativeInteger,
|
|
ups04InputCurrent NonNegativeInteger,
|
|
ups04InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups04InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups04InputEntry 1 }
|
|
|
|
ups04InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups04InputEntry 2 }
|
|
|
|
ups04InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups04InputEntry 3 }
|
|
|
|
ups04InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups04InputEntry 4 }
|
|
|
|
ups04InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups04InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups04Output OBJECT IDENTIFIER ::= { ups04Objects 4 }
|
|
|
|
ups04OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups04Output 1 }
|
|
|
|
ups04OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups04Output 2 }
|
|
|
|
ups04OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups04Output 3 }
|
|
|
|
ups04OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups04OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups04OutputNumLines."
|
|
::= { ups04Output 4 }
|
|
|
|
ups04OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups04OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups04OutputLineIndex }
|
|
::= { ups04OutputTable 1 }
|
|
|
|
Ups04OutputEntry ::= SEQUENCE {
|
|
ups04OutputLineIndex PositiveInteger,
|
|
ups04OutputVoltage NonNegativeInteger,
|
|
ups04OutputCurrent NonNegativeInteger,
|
|
ups04OutputPower NonNegativeInteger,
|
|
ups04OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups04OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups04OutputEntry 1 }
|
|
|
|
ups04OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups04OutputEntry 2 }
|
|
|
|
ups04OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups04OutputEntry 3 }
|
|
|
|
ups04OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups04OutputEntry 4 }
|
|
|
|
ups04OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups04OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups04Bypass OBJECT IDENTIFIER ::= { ups04Objects 5 }
|
|
|
|
ups04BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups04Bypass 1 }
|
|
|
|
ups04BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups04Bypass 2 }
|
|
|
|
ups04BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups04BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups04BypassNumLines."
|
|
::= { ups04Bypass 3 }
|
|
|
|
ups04BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups04BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups04BypassLineIndex }
|
|
::= { ups04BypassTable 1 }
|
|
|
|
Ups04BypassEntry ::= SEQUENCE {
|
|
ups04BypassLineIndex PositiveInteger,
|
|
ups04BypassVoltage NonNegativeInteger,
|
|
ups04BypassCurrent NonNegativeInteger,
|
|
ups04BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups04BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups04BypassEntry 1 }
|
|
|
|
ups04BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups04BypassEntry 2 }
|
|
|
|
ups04BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups04BypassEntry 3 }
|
|
|
|
ups04BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups04BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups04Alarm OBJECT IDENTIFIER ::= { ups04Objects 6 }
|
|
|
|
ups04AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups04Alarm 1 }
|
|
|
|
ups04AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups04AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups04AlarmId equal to 1, and increments the value of
|
|
ups04AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups04AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups04AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups04AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups04AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups04AlarmsPresent."
|
|
::= { ups04Alarm 2 }
|
|
|
|
ups04AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups04AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups04AlarmId }
|
|
::= { ups04AlarmTable 1 }
|
|
|
|
Ups04AlarmEntry ::= SEQUENCE {
|
|
ups04AlarmId PositiveInteger,
|
|
ups04AlarmDescr AutonomousType,
|
|
ups04AlarmTime TimeStamp
|
|
}
|
|
|
|
ups04AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups04AlarmEntry 1 }
|
|
|
|
ups04AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups04AlarmEntry 2 }
|
|
|
|
ups04AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups04AlarmTime shall equal
|
|
0."
|
|
::= { ups04AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups04WellKnownAlarms OBJECT IDENTIFIER ::= { ups04Alarm 3 }
|
|
ups04AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups04WellKnownAlarms 1 }
|
|
|
|
ups04AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups04WellKnownAlarms 2 }
|
|
|
|
ups04AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups04ConfigLowBattTime."
|
|
::= { ups04WellKnownAlarms 3 }
|
|
|
|
|
|
ups04AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups04WellKnownAlarms 4 }
|
|
|
|
ups04AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups04WellKnownAlarms 5 }
|
|
|
|
ups04AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups04WellKnownAlarms 6 }
|
|
|
|
ups04AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups04WellKnownAlarms 7 }
|
|
|
|
ups04AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups04WellKnownAlarms 8 }
|
|
|
|
ups04AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups04WellKnownAlarms 9 }
|
|
|
|
ups04AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups04WellKnownAlarms 10 }
|
|
|
|
ups04AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups04WellKnownAlarms 11 }
|
|
|
|
ups04AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups04WellKnownAlarms 12 }
|
|
|
|
ups04AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups04WellKnownAlarms 13 }
|
|
|
|
ups04AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups04WellKnownAlarms 14 }
|
|
|
|
ups04AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups04WellKnownAlarms 15 }
|
|
|
|
ups04AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups04WellKnownAlarms 16 }
|
|
|
|
ups04AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups04WellKnownAlarms 17 }
|
|
|
|
ups04AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups04WellKnownAlarms 18 }
|
|
|
|
ups04AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups04WellKnownAlarms 19 }
|
|
|
|
ups04AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups04WellKnownAlarms 20 }
|
|
|
|
ups04AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups04WellKnownAlarms 21 }
|
|
|
|
ups04AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups04ShutdownAfterDelay countdown is underway."
|
|
::= { ups04WellKnownAlarms 22 }
|
|
|
|
ups04AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups04WellKnownAlarms 23 }
|
|
|
|
ups04AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups04WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups04Test OBJECT IDENTIFIER ::= { ups04Objects 7 }
|
|
|
|
ups04TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups04TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups04TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups04TestId variable to
|
|
ups04TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups04TestNoTestsInitiated is returned."
|
|
::= { ups04Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups04TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups04TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups04TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups04TestResultsSummary */
|
|
get (upsTestSpinLock, ups04TestResultsSummary,
|
|
ups04TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups04TestResultsSummary,
|
|
ups04TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups04TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups04TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups04Test 2 }
|
|
|
|
ups04TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups04TestId to ups04TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups04Test 3 }
|
|
|
|
ups04TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups04TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups04Test 4 }
|
|
|
|
ups04TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups04TestResultsSummary is noTestsInitiated(6),
|
|
ups04TestStartTime has the value 0."
|
|
::= { ups04Test 5 }
|
|
|
|
ups04TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups04TestResultsSummary is noTestsInitiated(6),
|
|
ups04TestElapsedTime has the value 0."
|
|
::= { ups04Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups04WellKnownTests OBJECT IDENTIFIER ::= { ups04Test 7 }
|
|
|
|
|
|
ups04TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups04WellKnownTests 1 }
|
|
|
|
ups04TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups04WellKnownTests 2 }
|
|
|
|
ups04TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups04WellKnownTests 3 }
|
|
|
|
ups04TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups04WellKnownTests 4 }
|
|
|
|
ups04TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups04WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups04Control OBJECT IDENTIFIER ::= { ups04Objects 8 }
|
|
|
|
ups04ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups04ShutdownAfterDelay and ups04RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups04Control 1 }
|
|
|
|
ups04ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups04ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups04ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups04ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups04ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups04ShutdownAfterDelay already in effect."
|
|
::= { ups04Control 2 }
|
|
|
|
ups04StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups04StartupAfterDelay
|
|
countdown or ups04RebootWithDuration countdown in
|
|
progress. When read, ups04StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups04Control 3 }
|
|
|
|
ups04RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups04ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups04RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups04Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups04Traps OBJECT IDENTIFIER ::= { upsModule4 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups04TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups04EstimatedMinutesRemaining, ups04SecondsOnBattery,
|
|
ups04ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups04Traps 1 }
|
|
|
|
ups04TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups04TestId, ups04TestSpinLock,
|
|
ups04TestResultsSummary, ups04TestResultsDetail,
|
|
ups04TestStartTime, ups04TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups04Traps 2 }
|
|
|
|
ups04TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups04AlarmId, ups04AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups04AlarmOnBattery and
|
|
ups04AlarmTestInProgress."
|
|
::= { ups04Traps 3 }
|
|
|
|
ups04TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups04AlarmId, ups04AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups04AlarmTestInProgress."
|
|
::= { ups04Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups04Conformance OBJECT IDENTIFIER ::= { upsModule4 3 }
|
|
|
|
ups04Compliances OBJECT IDENTIFIER ::= { ups04Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups04SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups04SubsetIdentGroup,
|
|
ups04SubsetBatteryGroup, ups04SubsetInputGroup,
|
|
ups04SubsetOutputGroup, ups04SubsetAlarmGroup,
|
|
ups04SubsetControlGroup }
|
|
|
|
OBJECT ups04BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups04AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups04AlarmOnBattery, ups04AlarmLowBattery,
|
|
ups04AlarmInputBad, ups04AlarmUpsOutputOff,
|
|
ups04AlarmUpsSystemOff, and ups04AlarmTestInProgress."
|
|
|
|
OBJECT ups04OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups04ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups04Compliances 1 }
|
|
|
|
ups04BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups04BasicIdentGroup,
|
|
ups04BasicBatteryGroup, ups04BasicInputGroup,
|
|
ups04BasicOutputGroup, ups04BasicAlarmGroup,
|
|
ups04BasicTestGroup, ups04BasicControlGroup }
|
|
|
|
|
|
OBJECT ups04AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups04AlarmOnBattery, ups04AlarmLowBattery,
|
|
ups04AlarmDepletedBattery, ups04AlarmTempBad,
|
|
ups04AlarmInputBad, ups04AlarmOutputOverload,
|
|
ups04AlarmOnBypass, ups04AlarmBypassBad,
|
|
ups04AlarmOutputOffAsRequested,
|
|
ups04AlarmUpsOffAsRequested, ups04AlarmUpsOutputOff,
|
|
ups04AlarmUpsSystemOff, ups04AlarmGeneralFault,
|
|
ups04AlarmDiagnosticTestFailed,
|
|
ups04AlarmCommunicationsLost, ups04AlarmShutdownPending,
|
|
and ups04AlarmTestInProgress."
|
|
|
|
OBJECT ups04TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups04TestNoTestsInitiated."
|
|
|
|
OBJECT ups04OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups04BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups04BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups04ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups04Compliances 2 }
|
|
|
|
ups04FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups04FullIdentGroup, ups04FullBatteryGroup,
|
|
ups04FullInputGroup, ups04FullOutputGroup,
|
|
ups04FullAlarmGroup, ups04FullTestGroup,
|
|
ups04FullControlGroup }
|
|
|
|
OBJECT ups04AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups04AlarmBatteryBad, ups04AlarmOnBattery,
|
|
ups04AlarmLowBattery, ups04AlarmDepletedBattery,
|
|
ups04AlarmTempBad, ups04AlarmInputBad, ups04AlarmOnBypass,
|
|
ups04AlarmBypassBad, ups04AlarmOutputOffAsRequested,
|
|
ups04AlarmUpsOffAsRequested, ups04AlarmUpsOutputOff,
|
|
ups04AlarmUpsSystemOff, ups04AlarmGeneralFault,
|
|
ups04AlarmDiagnosticTestFailed,
|
|
ups04AlarmCommunicationsLost, ups04AlarmShutdownPending,
|
|
and ups04AlarmTestInProgress."
|
|
|
|
OBJECT ups04TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups04TestNoTestsInitiated,
|
|
ups04TestGeneralSystemsTest, and
|
|
ups04TestQuickBatteryTest."
|
|
|
|
OBJECT ups04OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups04FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups04FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups04ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups04Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups04Groups OBJECT IDENTIFIER ::= { ups04Conformance 2 }
|
|
|
|
ups04SubsetGroups OBJECT IDENTIFIER ::= { ups04Groups 1 }
|
|
|
|
ups04SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups04IdentManufacturer, ups04IdentModel,
|
|
ups04IdentAgentSoftwareVersion, ups04IdentName,
|
|
ups04IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups04SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups04SubsetGroups 1 }
|
|
|
|
ups04SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups04BatteryStatus, ups04SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups04SubsetGroups 2 }
|
|
|
|
ups04SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups04InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups04SubsetGroups 3 }
|
|
|
|
ups04SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups04OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups04SubsetGroups 4 }
|
|
|
|
|
|
-- { ups04SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups04SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups04AlarmsPresent, ups04AlarmDescr, ups04AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups04SubsetGroups 6 }
|
|
|
|
-- { ups04SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups04SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups04ShutdownType, ups04ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups04SubsetGroups 8 }
|
|
|
|
ups04BasicGroups OBJECT IDENTIFIER ::= { ups04Groups 2 }
|
|
|
|
ups04BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups04IdentManufacturer, ups04IdentModel,
|
|
ups04IdentUPSSoftwareVersion,
|
|
ups04IdentAgentSoftwareVersion, ups04IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 1 }
|
|
|
|
ups04BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups04BatteryStatus, ups04SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 2 }
|
|
|
|
ups04BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups04InputLineBads, ups04InputNumLines,
|
|
ups04InputFrequency, ups04InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 3 }
|
|
|
|
ups04BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups04OutputSource, ups04OutputFrequency,
|
|
ups04OutputNumLines, ups04OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 4 }
|
|
|
|
ups04BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups04BypassFrequency, ups04BypassNumLines,
|
|
ups04BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 5 }
|
|
|
|
ups04BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups04AlarmsPresent, ups04AlarmDescr, ups04AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups04BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 6 }
|
|
|
|
ups04BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups04TestId, ups04TestSpinLock,
|
|
ups04TestResultsSummary, ups04TestResultsDetail,
|
|
ups04TestStartTime, ups04TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 7 }
|
|
|
|
ups04BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups04ShutdownType, ups04ShutdownAfterDelay,
|
|
ups04StartupAfterDelay, ups04RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups04BasicGroups 8 }
|
|
|
|
ups04FullGroups OBJECT IDENTIFIER ::= { ups04Groups 3 }
|
|
|
|
ups04FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups04IdentManufacturer, ups04IdentModel,
|
|
ups04IdentUPSSoftwareVersion,
|
|
ups04IdentAgentSoftwareVersion, ups04IdentName,
|
|
ups04IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups04FullGroups 1 }
|
|
|
|
ups04FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups04BatteryStatus, ups04SecondsOnBattery,
|
|
ups04EstimatedMinutesRemaining,
|
|
ups04EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 2 }
|
|
|
|
ups04FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups04InputLineBads, ups04InputNumLines,
|
|
ups04InputFrequency, ups04InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 3 }
|
|
|
|
ups04FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups04OutputSource, ups04OutputFrequency,
|
|
ups04OutputNumLines, ups04OutputVoltage,
|
|
ups04OutputCurrent, ups04OutputPower,
|
|
ups04OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 4 }
|
|
|
|
ups04FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups04BypassFrequency, ups04BypassNumLines,
|
|
ups04BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 5 }
|
|
|
|
ups04FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups04AlarmsPresent, ups04AlarmDescr, ups04AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups04FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 6 }
|
|
|
|
ups04FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups04TestId, ups04TestSpinLock,
|
|
ups04TestResultsSummary, ups04TestResultsDetail,
|
|
ups04TestStartTime, ups04TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 7 }
|
|
|
|
ups04FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups04ShutdownType, ups04ShutdownAfterDelay,
|
|
ups04StartupAfterDelay, ups04RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups04FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups04FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 5 data
|
|
--
|
|
|
|
upsModule5 OBJECT IDENTIFIER ::= { upsModular 6 }
|
|
ups05Objects OBJECT IDENTIFIER ::= { upsModule5 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups05IdentName and
|
|
-- ups05IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups05Ident OBJECT IDENTIFIER ::= { ups05Objects 1 }
|
|
|
|
ups05IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups05Ident 1 }
|
|
|
|
ups05IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups05Ident 2 }
|
|
|
|
ups05IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups05IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups05Ident 3 }
|
|
|
|
ups05IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups05IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups05Ident 4 }
|
|
|
|
ups05IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups05Ident 5 }
|
|
|
|
ups05IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups05Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups05Battery OBJECT IDENTIFIER ::= { ups05Objects 2 }
|
|
|
|
ups05BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups05ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups05ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups05Battery 1 }
|
|
|
|
ups05SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups05Battery 2 }
|
|
|
|
ups05EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups05Battery 3 }
|
|
|
|
ups05EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups05Battery 4 }
|
|
|
|
ups05BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups05Battery 5 }
|
|
|
|
ups05BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups05Battery 6 }
|
|
|
|
ups05BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups05Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups05Input OBJECT IDENTIFIER ::= { ups05Objects 3 }
|
|
|
|
ups05InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups05Input 1 }
|
|
|
|
|
|
ups05InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups05Input 2 }
|
|
|
|
ups05InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups05InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups05InputNumLines."
|
|
::= { ups05Input 3 }
|
|
|
|
ups05InputEntry OBJECT-TYPE
|
|
SYNTAX Ups05InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups05InputLineIndex }
|
|
::= { ups05InputTable 1 }
|
|
|
|
Ups05InputEntry ::= SEQUENCE {
|
|
ups05InputLineIndex PositiveInteger,
|
|
ups05InputFrequency NonNegativeInteger,
|
|
ups05InputVoltage NonNegativeInteger,
|
|
ups05InputCurrent NonNegativeInteger,
|
|
ups05InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups05InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups05InputEntry 1 }
|
|
|
|
ups05InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups05InputEntry 2 }
|
|
|
|
ups05InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups05InputEntry 3 }
|
|
|
|
ups05InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups05InputEntry 4 }
|
|
|
|
ups05InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups05InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups05Output OBJECT IDENTIFIER ::= { ups05Objects 4 }
|
|
|
|
ups05OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups05Output 1 }
|
|
|
|
ups05OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups05Output 2 }
|
|
|
|
ups05OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups05Output 3 }
|
|
|
|
ups05OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups05OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups05OutputNumLines."
|
|
::= { ups05Output 4 }
|
|
|
|
ups05OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups05OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups05OutputLineIndex }
|
|
::= { ups05OutputTable 1 }
|
|
|
|
Ups05OutputEntry ::= SEQUENCE {
|
|
ups05OutputLineIndex PositiveInteger,
|
|
ups05OutputVoltage NonNegativeInteger,
|
|
ups05OutputCurrent NonNegativeInteger,
|
|
ups05OutputPower NonNegativeInteger,
|
|
ups05OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups05OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups05OutputEntry 1 }
|
|
|
|
ups05OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups05OutputEntry 2 }
|
|
|
|
ups05OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups05OutputEntry 3 }
|
|
|
|
ups05OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups05OutputEntry 4 }
|
|
|
|
ups05OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups05OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups05Bypass OBJECT IDENTIFIER ::= { ups05Objects 5 }
|
|
|
|
ups05BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups05Bypass 1 }
|
|
|
|
ups05BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups05Bypass 2 }
|
|
|
|
ups05BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups05BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups05BypassNumLines."
|
|
::= { ups05Bypass 3 }
|
|
|
|
ups05BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups05BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups05BypassLineIndex }
|
|
::= { ups05BypassTable 1 }
|
|
|
|
Ups05BypassEntry ::= SEQUENCE {
|
|
ups05BypassLineIndex PositiveInteger,
|
|
ups05BypassVoltage NonNegativeInteger,
|
|
ups05BypassCurrent NonNegativeInteger,
|
|
ups05BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups05BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups05BypassEntry 1 }
|
|
|
|
ups05BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups05BypassEntry 2 }
|
|
|
|
ups05BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups05BypassEntry 3 }
|
|
|
|
ups05BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups05BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups05Alarm OBJECT IDENTIFIER ::= { ups05Objects 6 }
|
|
|
|
ups05AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups05Alarm 1 }
|
|
|
|
ups05AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups05AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups05AlarmId equal to 1, and increments the value of
|
|
ups05AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups05AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups05AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups05AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups05AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups05AlarmsPresent."
|
|
::= { ups05Alarm 2 }
|
|
|
|
ups05AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups05AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups05AlarmId }
|
|
::= { ups05AlarmTable 1 }
|
|
|
|
Ups05AlarmEntry ::= SEQUENCE {
|
|
ups05AlarmId PositiveInteger,
|
|
ups05AlarmDescr AutonomousType,
|
|
ups05AlarmTime TimeStamp
|
|
}
|
|
|
|
ups05AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups05AlarmEntry 1 }
|
|
|
|
ups05AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups05AlarmEntry 2 }
|
|
|
|
ups05AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups05AlarmTime shall equal
|
|
0."
|
|
::= { ups05AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups05WellKnownAlarms OBJECT IDENTIFIER ::= { ups05Alarm 3 }
|
|
ups05AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups05WellKnownAlarms 1 }
|
|
|
|
ups05AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups05WellKnownAlarms 2 }
|
|
|
|
ups05AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups05ConfigLowBattTime."
|
|
::= { ups05WellKnownAlarms 3 }
|
|
|
|
|
|
ups05AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups05WellKnownAlarms 4 }
|
|
|
|
ups05AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups05WellKnownAlarms 5 }
|
|
|
|
ups05AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups05WellKnownAlarms 6 }
|
|
|
|
ups05AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups05WellKnownAlarms 7 }
|
|
|
|
ups05AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups05WellKnownAlarms 8 }
|
|
|
|
ups05AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups05WellKnownAlarms 9 }
|
|
|
|
ups05AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups05WellKnownAlarms 10 }
|
|
|
|
ups05AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups05WellKnownAlarms 11 }
|
|
|
|
ups05AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups05WellKnownAlarms 12 }
|
|
|
|
ups05AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups05WellKnownAlarms 13 }
|
|
|
|
ups05AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups05WellKnownAlarms 14 }
|
|
|
|
ups05AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups05WellKnownAlarms 15 }
|
|
|
|
ups05AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups05WellKnownAlarms 16 }
|
|
|
|
ups05AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups05WellKnownAlarms 17 }
|
|
|
|
ups05AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups05WellKnownAlarms 18 }
|
|
|
|
ups05AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups05WellKnownAlarms 19 }
|
|
|
|
ups05AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups05WellKnownAlarms 20 }
|
|
|
|
ups05AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups05WellKnownAlarms 21 }
|
|
|
|
ups05AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups05ShutdownAfterDelay countdown is underway."
|
|
::= { ups05WellKnownAlarms 22 }
|
|
|
|
ups05AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups05WellKnownAlarms 23 }
|
|
|
|
ups05AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups05WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups05Test OBJECT IDENTIFIER ::= { ups05Objects 7 }
|
|
|
|
ups05TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups05TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups05TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups05TestId variable to
|
|
ups05TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups05TestNoTestsInitiated is returned."
|
|
::= { ups05Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups05TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups05TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups05TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups05TestResultsSummary */
|
|
get (upsTestSpinLock, ups05TestResultsSummary,
|
|
ups05TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups05TestResultsSummary,
|
|
ups05TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups05TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups05TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups05Test 2 }
|
|
|
|
ups05TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups05TestId to ups05TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups05Test 3 }
|
|
|
|
ups05TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups05TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups05Test 4 }
|
|
|
|
ups05TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups05TestResultsSummary is noTestsInitiated(6),
|
|
ups05TestStartTime has the value 0."
|
|
::= { ups05Test 5 }
|
|
|
|
ups05TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups05TestResultsSummary is noTestsInitiated(6),
|
|
ups05TestElapsedTime has the value 0."
|
|
::= { ups05Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups05WellKnownTests OBJECT IDENTIFIER ::= { ups05Test 7 }
|
|
|
|
|
|
ups05TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups05WellKnownTests 1 }
|
|
|
|
ups05TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups05WellKnownTests 2 }
|
|
|
|
ups05TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups05WellKnownTests 3 }
|
|
|
|
ups05TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups05WellKnownTests 4 }
|
|
|
|
ups05TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups05WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups05Control OBJECT IDENTIFIER ::= { ups05Objects 8 }
|
|
|
|
ups05ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups05ShutdownAfterDelay and ups05RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups05Control 1 }
|
|
|
|
ups05ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups05ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups05ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups05ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups05ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups05ShutdownAfterDelay already in effect."
|
|
::= { ups05Control 2 }
|
|
|
|
ups05StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups05StartupAfterDelay
|
|
countdown or ups05RebootWithDuration countdown in
|
|
progress. When read, ups05StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups05Control 3 }
|
|
|
|
ups05RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups05ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups05RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups05Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups05Traps OBJECT IDENTIFIER ::= { upsModule5 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups05TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups05EstimatedMinutesRemaining, ups05SecondsOnBattery,
|
|
ups05ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups05Traps 1 }
|
|
|
|
ups05TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups05TestId, ups05TestSpinLock,
|
|
ups05TestResultsSummary, ups05TestResultsDetail,
|
|
ups05TestStartTime, ups05TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups05Traps 2 }
|
|
|
|
ups05TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups05AlarmId, ups05AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups05AlarmOnBattery and
|
|
ups05AlarmTestInProgress."
|
|
::= { ups05Traps 3 }
|
|
|
|
ups05TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups05AlarmId, ups05AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups05AlarmTestInProgress."
|
|
::= { ups05Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups05Conformance OBJECT IDENTIFIER ::= { upsModule5 3 }
|
|
|
|
ups05Compliances OBJECT IDENTIFIER ::= { ups05Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups05SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups05SubsetIdentGroup,
|
|
ups05SubsetBatteryGroup, ups05SubsetInputGroup,
|
|
ups05SubsetOutputGroup, ups05SubsetAlarmGroup,
|
|
ups05SubsetControlGroup }
|
|
|
|
OBJECT ups05BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups05AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups05AlarmOnBattery, ups05AlarmLowBattery,
|
|
ups05AlarmInputBad, ups05AlarmUpsOutputOff,
|
|
ups05AlarmUpsSystemOff, and ups05AlarmTestInProgress."
|
|
|
|
OBJECT ups05OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups05ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups05Compliances 1 }
|
|
|
|
ups05BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups05BasicIdentGroup,
|
|
ups05BasicBatteryGroup, ups05BasicInputGroup,
|
|
ups05BasicOutputGroup, ups05BasicAlarmGroup,
|
|
ups05BasicTestGroup, ups05BasicControlGroup }
|
|
|
|
|
|
OBJECT ups05AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups05AlarmOnBattery, ups05AlarmLowBattery,
|
|
ups05AlarmDepletedBattery, ups05AlarmTempBad,
|
|
ups05AlarmInputBad, ups05AlarmOutputOverload,
|
|
ups05AlarmOnBypass, ups05AlarmBypassBad,
|
|
ups05AlarmOutputOffAsRequested,
|
|
ups05AlarmUpsOffAsRequested, ups05AlarmUpsOutputOff,
|
|
ups05AlarmUpsSystemOff, ups05AlarmGeneralFault,
|
|
ups05AlarmDiagnosticTestFailed,
|
|
ups05AlarmCommunicationsLost, ups05AlarmShutdownPending,
|
|
and ups05AlarmTestInProgress."
|
|
|
|
OBJECT ups05TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups05TestNoTestsInitiated."
|
|
|
|
OBJECT ups05OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups05BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups05BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups05ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups05Compliances 2 }
|
|
|
|
ups05FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups05FullIdentGroup, ups05FullBatteryGroup,
|
|
ups05FullInputGroup, ups05FullOutputGroup,
|
|
ups05FullAlarmGroup, ups05FullTestGroup,
|
|
ups05FullControlGroup }
|
|
|
|
OBJECT ups05AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups05AlarmBatteryBad, ups05AlarmOnBattery,
|
|
ups05AlarmLowBattery, ups05AlarmDepletedBattery,
|
|
ups05AlarmTempBad, ups05AlarmInputBad, upsAlarmOnBypass,
|
|
ups05AlarmBypassBad, ups05AlarmOutputOffAsRequested,
|
|
ups05AlarmUpsOffAsRequested, ups05AlarmUpsOutputOff,
|
|
ups05AlarmUpsSystemOff, ups05AlarmGeneralFault,
|
|
ups05AlarmDiagnosticTestFailed,
|
|
ups05AlarmCommunicationsLost, ups05AlarmShutdownPending,
|
|
and ups05AlarmTestInProgress."
|
|
|
|
OBJECT ups05TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups05TestNoTestsInitiated,
|
|
ups05TestGeneralSystemsTest, and
|
|
ups05TestQuickBatteryTest."
|
|
|
|
OBJECT ups05OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups05FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups05FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups05ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups05Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups05Groups OBJECT IDENTIFIER ::= { ups05Conformance 2 }
|
|
|
|
ups05SubsetGroups OBJECT IDENTIFIER ::= { ups05Groups 1 }
|
|
|
|
ups05SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups05IdentManufacturer, ups05IdentModel,
|
|
ups05IdentAgentSoftwareVersion, ups05IdentName,
|
|
ups05IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups05SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups05SubsetGroups 1 }
|
|
|
|
ups05SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups05BatteryStatus, ups05SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups05SubsetGroups 2 }
|
|
|
|
ups05SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups05InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups05SubsetGroups 3 }
|
|
|
|
ups05SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups05OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups05SubsetGroups 4 }
|
|
|
|
|
|
-- { ups05SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups05SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups05AlarmsPresent, ups05AlarmDescr, ups05AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups05SubsetGroups 6 }
|
|
|
|
-- { ups05SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups05SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups05ShutdownType, ups05ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups05SubsetGroups 8 }
|
|
|
|
ups05BasicGroups OBJECT IDENTIFIER ::= { ups05Groups 2 }
|
|
|
|
ups05BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups05IdentManufacturer, ups05IdentModel,
|
|
ups05IdentUPSSoftwareVersion,
|
|
ups05IdentAgentSoftwareVersion, ups05IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 1 }
|
|
|
|
ups05BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups05BatteryStatus, ups05SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 2 }
|
|
|
|
ups05BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups05InputLineBads, ups05InputNumLines,
|
|
ups05InputFrequency, ups05InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 3 }
|
|
|
|
ups05BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups05OutputSource, ups05OutputFrequency,
|
|
ups05OutputNumLines, ups05OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 4 }
|
|
|
|
ups05BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups05BypassFrequency, ups05BypassNumLines,
|
|
ups05BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 5 }
|
|
|
|
ups05BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups05AlarmsPresent, ups05AlarmDescr, ups05AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups05BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 6 }
|
|
|
|
ups05BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups05TestId, ups05TestSpinLock,
|
|
ups05TestResultsSummary, ups05TestResultsDetail,
|
|
ups05TestStartTime, ups05TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 7 }
|
|
|
|
ups05BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups05ShutdownType, ups05ShutdownAfterDelay,
|
|
ups05StartupAfterDelay, ups05RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups05BasicGroups 8 }
|
|
|
|
ups05FullGroups OBJECT IDENTIFIER ::= { ups05Groups 3 }
|
|
|
|
ups05FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups05IdentManufacturer, ups05IdentModel,
|
|
ups05IdentUPSSoftwareVersion,
|
|
ups05IdentAgentSoftwareVersion, ups05IdentName,
|
|
ups05IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups05FullGroups 1 }
|
|
|
|
ups05FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups05BatteryStatus, ups05SecondsOnBattery,
|
|
ups05EstimatedMinutesRemaining,
|
|
ups05EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 2 }
|
|
|
|
ups05FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups05InputLineBads, ups05InputNumLines,
|
|
ups05InputFrequency, ups05InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 3 }
|
|
|
|
ups05FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups05OutputSource, ups05OutputFrequency,
|
|
ups05OutputNumLines, ups05OutputVoltage,
|
|
ups05OutputCurrent, ups05OutputPower,
|
|
ups05OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 4 }
|
|
|
|
ups05FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups05BypassFrequency, ups05BypassNumLines,
|
|
ups05BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 5 }
|
|
|
|
ups05FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups05AlarmsPresent, ups05AlarmDescr, ups05AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups05FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 6 }
|
|
|
|
ups05FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups05TestId, ups05TestSpinLock,
|
|
ups05TestResultsSummary, ups05TestResultsDetail,
|
|
ups05TestStartTime, ups05TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 7 }
|
|
|
|
ups05FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups05ShutdownType, ups05ShutdownAfterDelay,
|
|
ups05StartupAfterDelay, ups05RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups05FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups05FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 6 data
|
|
--
|
|
|
|
upsModule6 OBJECT IDENTIFIER ::= { upsModular 7 }
|
|
ups06Objects OBJECT IDENTIFIER ::= { upsModule6 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups06IdentName and
|
|
-- ups06IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups06Ident OBJECT IDENTIFIER ::= { ups06Objects 1 }
|
|
|
|
ups06IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups06Ident 1 }
|
|
|
|
ups06IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups06Ident 2 }
|
|
|
|
ups06IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups06IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups06Ident 3 }
|
|
|
|
ups06IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups06IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups06Ident 4 }
|
|
|
|
ups06IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups06Ident 5 }
|
|
|
|
ups06IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups06Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups06Battery OBJECT IDENTIFIER ::= { ups06Objects 2 }
|
|
|
|
ups06BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups06ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups06ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups06Battery 1 }
|
|
|
|
ups06SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups06Battery 2 }
|
|
|
|
ups06EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups06Battery 3 }
|
|
|
|
ups06EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups06Battery 4 }
|
|
|
|
ups06BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups06Battery 5 }
|
|
|
|
ups06BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups06Battery 6 }
|
|
|
|
ups06BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups06Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups06Input OBJECT IDENTIFIER ::= { ups06Objects 3 }
|
|
|
|
ups06InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups06Input 1 }
|
|
|
|
|
|
ups06InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups06Input 2 }
|
|
|
|
ups06InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups06InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups06InputNumLines."
|
|
::= { ups06Input 3 }
|
|
|
|
ups06InputEntry OBJECT-TYPE
|
|
SYNTAX Ups06InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups06InputLineIndex }
|
|
::= { ups06InputTable 1 }
|
|
|
|
Ups06InputEntry ::= SEQUENCE {
|
|
ups06InputLineIndex PositiveInteger,
|
|
ups06InputFrequency NonNegativeInteger,
|
|
ups06InputVoltage NonNegativeInteger,
|
|
ups06InputCurrent NonNegativeInteger,
|
|
ups06InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups06InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups06InputEntry 1 }
|
|
|
|
ups06InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups06InputEntry 2 }
|
|
|
|
ups06InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups06InputEntry 3 }
|
|
|
|
ups06InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups06InputEntry 4 }
|
|
|
|
ups06InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups06InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups06Output OBJECT IDENTIFIER ::= { ups06Objects 4 }
|
|
|
|
ups06OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups06Output 1 }
|
|
|
|
ups06OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups06Output 2 }
|
|
|
|
ups06OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups06Output 3 }
|
|
|
|
ups06OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups06OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups06OutputNumLines."
|
|
::= { ups06Output 4 }
|
|
|
|
ups06OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups06OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups06OutputLineIndex }
|
|
::= { ups06OutputTable 1 }
|
|
|
|
Ups06OutputEntry ::= SEQUENCE {
|
|
ups06OutputLineIndex PositiveInteger,
|
|
ups06OutputVoltage NonNegativeInteger,
|
|
ups06OutputCurrent NonNegativeInteger,
|
|
ups06OutputPower NonNegativeInteger,
|
|
ups06OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups06OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups06OutputEntry 1 }
|
|
|
|
ups06OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups06OutputEntry 2 }
|
|
|
|
ups06OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups06OutputEntry 3 }
|
|
|
|
ups06OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups06OutputEntry 4 }
|
|
|
|
ups06OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups06OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups06Bypass OBJECT IDENTIFIER ::= { ups06Objects 5 }
|
|
|
|
ups06BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups06Bypass 1 }
|
|
|
|
ups06BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups06Bypass 2 }
|
|
|
|
ups06BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups06BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups06BypassNumLines."
|
|
::= { ups06Bypass 3 }
|
|
|
|
ups06BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups06BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups06BypassLineIndex }
|
|
::= { ups06BypassTable 1 }
|
|
|
|
Ups06BypassEntry ::= SEQUENCE {
|
|
ups06BypassLineIndex PositiveInteger,
|
|
ups06BypassVoltage NonNegativeInteger,
|
|
ups06BypassCurrent NonNegativeInteger,
|
|
ups06BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups06BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups06BypassEntry 1 }
|
|
|
|
ups06BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups06BypassEntry 2 }
|
|
|
|
ups06BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups06BypassEntry 3 }
|
|
|
|
ups06BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups06BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups06Alarm OBJECT IDENTIFIER ::= { ups06Objects 6 }
|
|
|
|
ups06AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups06Alarm 1 }
|
|
|
|
ups06AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups06AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups06AlarmId equal to 1, and increments the value of
|
|
ups06AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups06AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups06AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups06AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups06AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups06AlarmsPresent."
|
|
::= { ups06Alarm 2 }
|
|
|
|
ups06AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups06AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups06AlarmId }
|
|
::= { ups06AlarmTable 1 }
|
|
|
|
Ups06AlarmEntry ::= SEQUENCE {
|
|
ups06AlarmId PositiveInteger,
|
|
ups06AlarmDescr AutonomousType,
|
|
ups06AlarmTime TimeStamp
|
|
}
|
|
|
|
ups06AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups06AlarmEntry 1 }
|
|
|
|
ups06AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups06AlarmEntry 2 }
|
|
|
|
ups06AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups06AlarmTime shall equal
|
|
0."
|
|
::= { ups06AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups06WellKnownAlarms OBJECT IDENTIFIER ::= { ups06Alarm 3 }
|
|
ups06AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups06WellKnownAlarms 1 }
|
|
|
|
ups06AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups06WellKnownAlarms 2 }
|
|
|
|
ups06AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups06ConfigLowBattTime."
|
|
::= { ups06WellKnownAlarms 3 }
|
|
|
|
|
|
ups06AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups06WellKnownAlarms 4 }
|
|
|
|
ups06AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups06WellKnownAlarms 5 }
|
|
|
|
ups06AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups06WellKnownAlarms 6 }
|
|
|
|
ups06AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups06WellKnownAlarms 7 }
|
|
|
|
ups06AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups06WellKnownAlarms 8 }
|
|
|
|
ups06AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups06WellKnownAlarms 9 }
|
|
|
|
ups06AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups06WellKnownAlarms 10 }
|
|
|
|
ups06AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups06WellKnownAlarms 11 }
|
|
|
|
ups06AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups06WellKnownAlarms 12 }
|
|
|
|
ups06AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups06WellKnownAlarms 13 }
|
|
|
|
ups06AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups06WellKnownAlarms 14 }
|
|
|
|
ups06AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups06WellKnownAlarms 15 }
|
|
|
|
ups06AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups06WellKnownAlarms 16 }
|
|
|
|
ups06AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups06WellKnownAlarms 17 }
|
|
|
|
ups06AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups06WellKnownAlarms 18 }
|
|
|
|
ups06AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups06WellKnownAlarms 19 }
|
|
|
|
ups06AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups06WellKnownAlarms 20 }
|
|
|
|
ups06AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups06WellKnownAlarms 21 }
|
|
|
|
ups06AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups06ShutdownAfterDelay countdown is underway."
|
|
::= { ups06WellKnownAlarms 22 }
|
|
|
|
ups06AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups06WellKnownAlarms 23 }
|
|
|
|
ups06AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups06WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups06Test OBJECT IDENTIFIER ::= { ups06Objects 7 }
|
|
|
|
ups06TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups06TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups06TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups06TestId variable to
|
|
ups06TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups06TestNoTestsInitiated is returned."
|
|
::= { ups06Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups06TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups06TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups06TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups06TestResultsSummary */
|
|
get (upsTestSpinLock, ups06TestResultsSummary,
|
|
ups06TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups06TestResultsSummary,
|
|
ups06TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups06TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups06TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups06Test 2 }
|
|
|
|
ups06TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups06TestId to ups06TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups06Test 3 }
|
|
|
|
ups06TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups06TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups06Test 4 }
|
|
|
|
ups06TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups06TestResultsSummary is noTestsInitiated(6),
|
|
ups06TestStartTime has the value 0."
|
|
::= { ups06Test 5 }
|
|
|
|
ups06TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups06TestResultsSummary is noTestsInitiated(6),
|
|
ups06TestElapsedTime has the value 0."
|
|
::= { ups06Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups06WellKnownTests OBJECT IDENTIFIER ::= { ups06Test 7 }
|
|
|
|
|
|
ups06TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups06WellKnownTests 1 }
|
|
|
|
ups06TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups06WellKnownTests 2 }
|
|
|
|
ups06TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups06WellKnownTests 3 }
|
|
|
|
ups06TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups06WellKnownTests 4 }
|
|
|
|
ups06TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups06WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups06Control OBJECT IDENTIFIER ::= { ups06Objects 8 }
|
|
|
|
ups06ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups06ShutdownAfterDelay and ups06RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups06Control 1 }
|
|
|
|
ups06ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups06ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups06ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups06ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups06ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups06ShutdownAfterDelay already in effect."
|
|
::= { ups06Control 2 }
|
|
|
|
ups06StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups06StartupAfterDelay
|
|
countdown or ups06RebootWithDuration countdown in
|
|
progress. When read, ups06StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups06Control 3 }
|
|
|
|
ups06RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups06ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups06RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups06Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups06Traps OBJECT IDENTIFIER ::= { upsModule6 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups06TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups06EstimatedMinutesRemaining, ups06SecondsOnBattery,
|
|
ups06ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups06Traps 1 }
|
|
|
|
ups06TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups06TestId, ups06TestSpinLock,
|
|
ups06TestResultsSummary, ups06TestResultsDetail,
|
|
ups06TestStartTime, ups06TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups06Traps 2 }
|
|
|
|
ups06TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups06AlarmId, ups06AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups06AlarmOnBattery and
|
|
ups06AlarmTestInProgress."
|
|
::= { ups06Traps 3 }
|
|
|
|
ups06TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups06AlarmId, ups06AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups06AlarmTestInProgress."
|
|
::= { ups06Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups06Conformance OBJECT IDENTIFIER ::= { upsModule6 3 }
|
|
|
|
ups06Compliances OBJECT IDENTIFIER ::= { ups06Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups06SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups06SubsetIdentGroup,
|
|
ups06SubsetBatteryGroup, ups06SubsetInputGroup,
|
|
ups06SubsetOutputGroup, ups06SubsetAlarmGroup,
|
|
ups06SubsetControlGroup }
|
|
|
|
OBJECT ups06BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups06AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups06AlarmOnBattery, ups06AlarmLowBattery,
|
|
ups06AlarmInputBad, ups06AlarmUpsOutputOff,
|
|
ups06AlarmUpsSystemOff, and ups06AlarmTestInProgress."
|
|
|
|
OBJECT ups06OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups06ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups06Compliances 1 }
|
|
|
|
ups06BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups06BasicIdentGroup,
|
|
ups06BasicBatteryGroup, ups06BasicInputGroup,
|
|
ups06BasicOutputGroup, ups06BasicAlarmGroup,
|
|
ups06BasicTestGroup, ups06BasicControlGroup }
|
|
|
|
|
|
OBJECT ups06AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups06AlarmOnBattery, ups06AlarmLowBattery,
|
|
ups06AlarmDepletedBattery, ups06AlarmTempBad,
|
|
ups06AlarmInputBad, ups06AlarmOutputOverload,
|
|
ups06AlarmOnBypass, ups06AlarmBypassBad,
|
|
ups06AlarmOutputOffAsRequested,
|
|
ups06AlarmUpsOffAsRequested, ups06AlarmUpsOutputOff,
|
|
ups06AlarmUpsSystemOff, ups06AlarmGeneralFault,
|
|
ups06AlarmDiagnosticTestFailed,
|
|
ups06AlarmCommunicationsLost, ups06AlarmShutdownPending,
|
|
and ups06AlarmTestInProgress."
|
|
|
|
OBJECT ups06TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups06TestNoTestsInitiated."
|
|
|
|
OBJECT ups06OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups06BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups06BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups06ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups06Compliances 2 }
|
|
|
|
ups06FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups06FullIdentGroup, ups06FullBatteryGroup,
|
|
ups06FullInputGroup, ups06FullOutputGroup,
|
|
ups06FullAlarmGroup, ups06FullTestGroup,
|
|
ups06FullControlGroup }
|
|
|
|
OBJECT ups06AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups06AlarmBatteryBad, ups06AlarmOnBattery,
|
|
ups06AlarmLowBattery, ups06AlarmDepletedBattery,
|
|
ups06AlarmTempBad, ups06AlarmInputBad, ups06AlarmOnBypass,
|
|
ups06AlarmBypassBad, ups06AlarmOutputOffAsRequested,
|
|
ups06AlarmUpsOffAsRequested, ups06AlarmUpsOutputOff,
|
|
ups06AlarmUpsSystemOff, ups06AlarmGeneralFault,
|
|
ups06AlarmDiagnosticTestFailed,
|
|
ups06AlarmCommunicationsLost, ups06AlarmShutdownPending,
|
|
and ups06AlarmTestInProgress."
|
|
|
|
OBJECT ups06TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups06TestNoTestsInitiated,
|
|
ups06TestGeneralSystemsTest, and
|
|
ups06TestQuickBatteryTest."
|
|
|
|
OBJECT ups06OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups06FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups06FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups06ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups06Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups06Groups OBJECT IDENTIFIER ::= { ups06Conformance 2 }
|
|
|
|
ups06SubsetGroups OBJECT IDENTIFIER ::= { ups06Groups 1 }
|
|
|
|
ups06SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups06IdentManufacturer, ups06IdentModel,
|
|
ups06IdentAgentSoftwareVersion, ups06IdentName,
|
|
ups06IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups06SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups06SubsetGroups 1 }
|
|
|
|
ups06SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups06BatteryStatus, ups06SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups06SubsetGroups 2 }
|
|
|
|
ups06SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups06InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups06SubsetGroups 3 }
|
|
|
|
ups06SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups06OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups06SubsetGroups 4 }
|
|
|
|
|
|
-- { ups06SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups06SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups06AlarmsPresent, ups06AlarmDescr, ups06AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups06SubsetGroups 6 }
|
|
|
|
-- { ups06SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups06SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups06ShutdownType, ups06ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups06SubsetGroups 8 }
|
|
|
|
ups06BasicGroups OBJECT IDENTIFIER ::= { ups06Groups 2 }
|
|
|
|
ups06BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups06IdentManufacturer, ups06IdentModel,
|
|
ups06IdentUPSSoftwareVersion,
|
|
ups06IdentAgentSoftwareVersion, ups06IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 1 }
|
|
|
|
ups06BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups06BatteryStatus, ups06SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 2 }
|
|
|
|
ups06BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups06InputLineBads, ups06InputNumLines,
|
|
ups06InputFrequency, ups06InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 3 }
|
|
|
|
ups06BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups06OutputSource, ups06OutputFrequency,
|
|
ups06OutputNumLines, ups06OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 4 }
|
|
|
|
ups06BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups06BypassFrequency, ups06BypassNumLines,
|
|
ups06BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 5 }
|
|
|
|
ups06BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups06AlarmsPresent, ups06AlarmDescr, ups06AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups06BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 6 }
|
|
|
|
ups06BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups06TestId, ups06TestSpinLock,
|
|
ups06TestResultsSummary, ups06TestResultsDetail,
|
|
ups06TestStartTime, ups06TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 7 }
|
|
|
|
ups06BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups06ShutdownType, ups06ShutdownAfterDelay,
|
|
ups06StartupAfterDelay, ups06RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups06BasicGroups 8 }
|
|
|
|
ups06FullGroups OBJECT IDENTIFIER ::= { ups06Groups 3 }
|
|
|
|
ups06FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups06IdentManufacturer, ups06IdentModel,
|
|
ups06IdentUPSSoftwareVersion,
|
|
ups06IdentAgentSoftwareVersion, ups06IdentName,
|
|
ups06IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups06FullGroups 1 }
|
|
|
|
ups06FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups06BatteryStatus, ups06SecondsOnBattery,
|
|
ups06EstimatedMinutesRemaining,
|
|
ups06EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 2 }
|
|
|
|
ups06FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups06InputLineBads, ups06InputNumLines,
|
|
ups06InputFrequency, ups06InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 3 }
|
|
|
|
ups06FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups06OutputSource, ups06OutputFrequency,
|
|
ups06OutputNumLines, ups06OutputVoltage,
|
|
ups06OutputCurrent, ups06OutputPower,
|
|
ups06OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 4 }
|
|
|
|
ups06FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups06BypassFrequency, ups06BypassNumLines,
|
|
ups06BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 5 }
|
|
|
|
ups06FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups06AlarmsPresent, ups06AlarmDescr, ups06AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups06FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 6 }
|
|
|
|
ups06FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups06TestId, ups06TestSpinLock,
|
|
ups06TestResultsSummary, ups06TestResultsDetail,
|
|
ups06TestStartTime, ups06TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 7 }
|
|
|
|
ups06FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups06ShutdownType, ups06ShutdownAfterDelay,
|
|
ups06StartupAfterDelay, ups06RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups06FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups06FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 7 data
|
|
--
|
|
|
|
upsModule7 OBJECT IDENTIFIER ::= { upsModular 8 }
|
|
ups07Objects OBJECT IDENTIFIER ::= { upsModule7 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups07IdentName and
|
|
-- ups07IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups07Ident OBJECT IDENTIFIER ::= { ups07Objects 1 }
|
|
|
|
ups07IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups07Ident 1 }
|
|
|
|
ups07IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups07Ident 2 }
|
|
|
|
ups07IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups07IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups07Ident 3 }
|
|
|
|
ups07IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups07IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups07Ident 4 }
|
|
|
|
ups07IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups07Ident 5 }
|
|
|
|
ups07IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups07Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups07Battery OBJECT IDENTIFIER ::= { ups07Objects 2 }
|
|
|
|
ups07BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups07ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups07ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups07Battery 1 }
|
|
|
|
ups07SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups07Battery 2 }
|
|
|
|
ups07EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups07Battery 3 }
|
|
|
|
ups07EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups07Battery 4 }
|
|
|
|
ups07BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups07Battery 5 }
|
|
|
|
ups07BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups07Battery 6 }
|
|
|
|
ups07BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups07Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups07Input OBJECT IDENTIFIER ::= { ups07Objects 3 }
|
|
|
|
ups07InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups07Input 1 }
|
|
|
|
|
|
ups07InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups07Input 2 }
|
|
|
|
ups07InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups07InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups07InputNumLines."
|
|
::= { ups07Input 3 }
|
|
|
|
ups07InputEntry OBJECT-TYPE
|
|
SYNTAX Ups07InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups07InputLineIndex }
|
|
::= { ups07InputTable 1 }
|
|
|
|
Ups07InputEntry ::= SEQUENCE {
|
|
ups07InputLineIndex PositiveInteger,
|
|
ups07InputFrequency NonNegativeInteger,
|
|
ups07InputVoltage NonNegativeInteger,
|
|
ups07InputCurrent NonNegativeInteger,
|
|
ups07InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups07InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups07InputEntry 1 }
|
|
|
|
ups07InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups07InputEntry 2 }
|
|
|
|
ups07InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups07InputEntry 3 }
|
|
|
|
ups07InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups07InputEntry 4 }
|
|
|
|
ups07InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups07InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups07Output OBJECT IDENTIFIER ::= { ups07Objects 4 }
|
|
|
|
ups07OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups07Output 1 }
|
|
|
|
ups07OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups07Output 2 }
|
|
|
|
ups07OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups07Output 3 }
|
|
|
|
ups07OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups07OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups07OutputNumLines."
|
|
::= { ups07Output 4 }
|
|
|
|
ups07OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups07OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups07OutputLineIndex }
|
|
::= { ups07OutputTable 1 }
|
|
|
|
Ups07OutputEntry ::= SEQUENCE {
|
|
ups07OutputLineIndex PositiveInteger,
|
|
ups07OutputVoltage NonNegativeInteger,
|
|
ups07OutputCurrent NonNegativeInteger,
|
|
ups07OutputPower NonNegativeInteger,
|
|
ups07OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups07OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups07OutputEntry 1 }
|
|
|
|
ups07OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups07OutputEntry 2 }
|
|
|
|
ups07OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups07OutputEntry 3 }
|
|
|
|
ups07OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups07OutputEntry 4 }
|
|
|
|
ups07OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups07OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups07Bypass OBJECT IDENTIFIER ::= { ups07Objects 5 }
|
|
|
|
ups07BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups07Bypass 1 }
|
|
|
|
ups07BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups07Bypass 2 }
|
|
|
|
ups07BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups07BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups07BypassNumLines."
|
|
::= { ups07Bypass 3 }
|
|
|
|
ups07BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups07BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups07BypassLineIndex }
|
|
::= { ups07BypassTable 1 }
|
|
|
|
Ups07BypassEntry ::= SEQUENCE {
|
|
ups07BypassLineIndex PositiveInteger,
|
|
ups07BypassVoltage NonNegativeInteger,
|
|
ups07BypassCurrent NonNegativeInteger,
|
|
ups07BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups07BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups07BypassEntry 1 }
|
|
|
|
ups07BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups07BypassEntry 2 }
|
|
|
|
ups07BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups07BypassEntry 3 }
|
|
|
|
ups07BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups07BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups07Alarm OBJECT IDENTIFIER ::= { ups07Objects 6 }
|
|
|
|
ups07AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups07Alarm 1 }
|
|
|
|
ups07AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups07AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups07AlarmId equal to 1, and increments the value of
|
|
ups07AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups07AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups07AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups07AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups07AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups07AlarmsPresent."
|
|
::= { ups07Alarm 2 }
|
|
|
|
ups07AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups07AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups07AlarmId }
|
|
::= { ups07AlarmTable 1 }
|
|
|
|
Ups07AlarmEntry ::= SEQUENCE {
|
|
ups07AlarmId PositiveInteger,
|
|
ups07AlarmDescr AutonomousType,
|
|
ups07AlarmTime TimeStamp
|
|
}
|
|
|
|
ups07AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups07AlarmEntry 1 }
|
|
|
|
ups07AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups07AlarmEntry 2 }
|
|
|
|
ups07AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups07AlarmTime shall equal
|
|
0."
|
|
::= { ups07AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups07WellKnownAlarms OBJECT IDENTIFIER ::= { ups07Alarm 3 }
|
|
ups07AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups07WellKnownAlarms 1 }
|
|
|
|
ups07AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups07WellKnownAlarms 2 }
|
|
|
|
ups07AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups07ConfigLowBattTime."
|
|
::= { ups07WellKnownAlarms 3 }
|
|
|
|
|
|
ups07AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups07WellKnownAlarms 4 }
|
|
|
|
ups07AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups07WellKnownAlarms 5 }
|
|
|
|
ups07AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups07WellKnownAlarms 6 }
|
|
|
|
ups07AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups07WellKnownAlarms 7 }
|
|
|
|
ups07AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups07WellKnownAlarms 8 }
|
|
|
|
ups07AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups07WellKnownAlarms 9 }
|
|
|
|
ups07AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups07WellKnownAlarms 10 }
|
|
|
|
ups07AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups07WellKnownAlarms 11 }
|
|
|
|
ups07AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups07WellKnownAlarms 12 }
|
|
|
|
ups07AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups07WellKnownAlarms 13 }
|
|
|
|
ups07AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups07WellKnownAlarms 14 }
|
|
|
|
ups07AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups07WellKnownAlarms 15 }
|
|
|
|
ups07AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups07WellKnownAlarms 16 }
|
|
|
|
ups07AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups07WellKnownAlarms 17 }
|
|
|
|
ups07AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups07WellKnownAlarms 18 }
|
|
|
|
ups07AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups07WellKnownAlarms 19 }
|
|
|
|
ups07AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups07WellKnownAlarms 20 }
|
|
|
|
ups07AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups07WellKnownAlarms 21 }
|
|
|
|
ups07AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups07ShutdownAfterDelay countdown is underway."
|
|
::= { ups07WellKnownAlarms 22 }
|
|
|
|
ups07AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups07WellKnownAlarms 23 }
|
|
|
|
ups07AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups07WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups07Test OBJECT IDENTIFIER ::= { ups07Objects 7 }
|
|
|
|
ups07TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups07TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups07TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups07TestId variable to
|
|
ups07TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups07TestNoTestsInitiated is returned."
|
|
::= { ups07Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups07TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups07TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups07TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups07TestResultsSummary */
|
|
get (upsTestSpinLock, ups07TestResultsSummary,
|
|
ups07TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups07TestResultsSummary,
|
|
ups07TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups07TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups07TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups07Test 2 }
|
|
|
|
ups07TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups07TestId to ups07TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups07Test 3 }
|
|
|
|
ups07TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups07TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups07Test 4 }
|
|
|
|
ups07TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups07TestResultsSummary is noTestsInitiated(6),
|
|
ups07TestStartTime has the value 0."
|
|
::= { ups07Test 5 }
|
|
|
|
ups07TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups07TestResultsSummary is noTestsInitiated(6),
|
|
ups07TestElapsedTime has the value 0."
|
|
::= { ups07Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups07WellKnownTests OBJECT IDENTIFIER ::= { ups07Test 7 }
|
|
|
|
|
|
ups07TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups07WellKnownTests 1 }
|
|
|
|
ups07TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups07WellKnownTests 2 }
|
|
|
|
ups07TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups07WellKnownTests 3 }
|
|
|
|
ups07TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups07WellKnownTests 4 }
|
|
|
|
ups07TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups07WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups07Control OBJECT IDENTIFIER ::= { ups07Objects 8 }
|
|
|
|
ups07ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups07ShutdownAfterDelay and ups07RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups07Control 1 }
|
|
|
|
ups07ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups07ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups07ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups07ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups07ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups07ShutdownAfterDelay already in effect."
|
|
::= { ups07Control 2 }
|
|
|
|
ups07StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups07StartupAfterDelay
|
|
countdown or ups07RebootWithDuration countdown in
|
|
progress. When read, ups07StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups07Control 3 }
|
|
|
|
ups07RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups07ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups07RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups07Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups07Traps OBJECT IDENTIFIER ::= { upsModule7 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups07TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups07EstimatedMinutesRemaining, ups07SecondsOnBattery,
|
|
ups07ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups07Traps 1 }
|
|
|
|
ups07TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups07TestId, ups07TestSpinLock,
|
|
ups07TestResultsSummary, ups07TestResultsDetail,
|
|
ups07TestStartTime, ups07TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups07Traps 2 }
|
|
|
|
ups07TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups07AlarmId, ups07AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups07AlarmOnBattery and
|
|
ups07AlarmTestInProgress."
|
|
::= { ups07Traps 3 }
|
|
|
|
ups07TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups07AlarmId, ups07AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups07AlarmTestInProgress."
|
|
::= { ups07Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups07Conformance OBJECT IDENTIFIER ::= { upsModule7 3 }
|
|
|
|
ups07Compliances OBJECT IDENTIFIER ::= { ups07Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups07SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups07SubsetIdentGroup,
|
|
ups07SubsetBatteryGroup, ups07SubsetInputGroup,
|
|
ups07SubsetOutputGroup, ups07SubsetAlarmGroup,
|
|
ups07SubsetControlGroup }
|
|
|
|
OBJECT ups07BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups07AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups07AlarmOnBattery, ups07AlarmLowBattery,
|
|
ups07AlarmInputBad, ups07AlarmUpsOutputOff,
|
|
ups07AlarmUpsSystemOff, and ups07AlarmTestInProgress."
|
|
|
|
OBJECT ups07OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups07ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups07Compliances 1 }
|
|
|
|
ups07BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups07BasicIdentGroup,
|
|
ups07BasicBatteryGroup, ups07BasicInputGroup,
|
|
ups07BasicOutputGroup, ups07BasicAlarmGroup,
|
|
ups07BasicTestGroup, ups07BasicControlGroup }
|
|
|
|
|
|
OBJECT ups07AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups07AlarmOnBattery, ups07AlarmLowBattery,
|
|
ups07AlarmDepletedBattery, ups07AlarmTempBad,
|
|
ups07AlarmInputBad, ups07AlarmOutputOverload,
|
|
ups07AlarmOnBypass, ups07AlarmBypassBad,
|
|
ups07AlarmOutputOffAsRequested,
|
|
ups07AlarmUpsOffAsRequested, ups07AlarmUpsOutputOff,
|
|
ups07AlarmUpsSystemOff, ups07AlarmGeneralFault,
|
|
ups07AlarmDiagnosticTestFailed,
|
|
ups07AlarmCommunicationsLost, ups07AlarmShutdownPending,
|
|
and ups07AlarmTestInProgress."
|
|
|
|
OBJECT ups07TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups07TestNoTestsInitiated."
|
|
|
|
OBJECT ups07OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups07BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups07BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups07ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups07Compliances 2 }
|
|
|
|
ups07FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups07FullIdentGroup, ups07FullBatteryGroup,
|
|
ups07FullInputGroup, ups07FullOutputGroup,
|
|
ups07FullAlarmGroup, ups07FullTestGroup,
|
|
ups07FullControlGroup }
|
|
|
|
OBJECT ups07AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups07AlarmBatteryBad, ups07AlarmOnBattery,
|
|
ups07AlarmLowBattery, ups07AlarmDepletedBattery,
|
|
ups07AlarmTempBad, ups07AlarmInputBad, ups07AlarmOnBypass,
|
|
ups07AlarmBypassBad, ups07AlarmOutputOffAsRequested,
|
|
ups07AlarmUpsOffAsRequested, ups07AlarmUpsOutputOff,
|
|
ups07AlarmUpsSystemOff, ups07AlarmGeneralFault,
|
|
ups07AlarmDiagnosticTestFailed,
|
|
ups07AlarmCommunicationsLost, ups07AlarmShutdownPending,
|
|
and ups07AlarmTestInProgress."
|
|
|
|
OBJECT ups07TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups07TestNoTestsInitiated,
|
|
ups07TestGeneralSystemsTest, and
|
|
ups07TestQuickBatteryTest."
|
|
|
|
OBJECT ups07OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups07FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups07FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups07ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups07Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups07Groups OBJECT IDENTIFIER ::= { ups07Conformance 2 }
|
|
|
|
ups07SubsetGroups OBJECT IDENTIFIER ::= { ups07Groups 1 }
|
|
|
|
ups07SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups07IdentManufacturer, ups07IdentModel,
|
|
ups07IdentAgentSoftwareVersion, ups07IdentName,
|
|
ups07IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups07SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups07SubsetGroups 1 }
|
|
|
|
ups07SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups07BatteryStatus, ups07SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups07SubsetGroups 2 }
|
|
|
|
ups07SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups07InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups07SubsetGroups 3 }
|
|
|
|
ups07SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups07OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups07SubsetGroups 4 }
|
|
|
|
|
|
-- { ups07SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups07SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups07AlarmsPresent, ups07AlarmDescr, ups07AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups07SubsetGroups 6 }
|
|
|
|
-- { ups07SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups07SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups07ShutdownType, ups07ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups07SubsetGroups 8 }
|
|
|
|
ups07BasicGroups OBJECT IDENTIFIER ::= { ups07Groups 2 }
|
|
|
|
ups07BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups07IdentManufacturer, ups07IdentModel,
|
|
ups07IdentUPSSoftwareVersion,
|
|
ups07IdentAgentSoftwareVersion, ups07IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 1 }
|
|
|
|
ups07BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups07BatteryStatus, ups07SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 2 }
|
|
|
|
ups07BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups07InputLineBads, ups07InputNumLines,
|
|
ups07InputFrequency, ups07InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 3 }
|
|
|
|
ups07BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups07OutputSource, ups07OutputFrequency,
|
|
ups07OutputNumLines, ups07OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 4 }
|
|
|
|
ups07BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups07BypassFrequency, ups07BypassNumLines,
|
|
ups07BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 5 }
|
|
|
|
ups07BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups07AlarmsPresent, ups07AlarmDescr, ups07AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups07BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 6 }
|
|
|
|
ups07BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups07TestId, ups07TestSpinLock,
|
|
ups07TestResultsSummary, ups07TestResultsDetail,
|
|
ups07TestStartTime, ups07TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 7 }
|
|
|
|
ups07BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups07ShutdownType, ups07ShutdownAfterDelay,
|
|
ups07StartupAfterDelay, ups07RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups07BasicGroups 8 }
|
|
|
|
ups07FullGroups OBJECT IDENTIFIER ::= { ups07Groups 3 }
|
|
|
|
ups07FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups07IdentManufacturer, ups07IdentModel,
|
|
ups07IdentUPSSoftwareVersion,
|
|
ups07IdentAgentSoftwareVersion, ups07IdentName,
|
|
ups07IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups07FullGroups 1 }
|
|
|
|
ups07FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups07BatteryStatus, ups07SecondsOnBattery,
|
|
ups07EstimatedMinutesRemaining,
|
|
ups07EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 2 }
|
|
|
|
ups07FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups07InputLineBads, ups07InputNumLines,
|
|
ups07InputFrequency, ups07InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 3 }
|
|
|
|
ups07FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups07OutputSource, ups07OutputFrequency,
|
|
ups07OutputNumLines, ups07OutputVoltage,
|
|
ups07OutputCurrent, ups07OutputPower,
|
|
ups07OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 4 }
|
|
|
|
ups07FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups07BypassFrequency, ups07BypassNumLines,
|
|
ups07BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 5 }
|
|
|
|
ups07FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups07AlarmsPresent, ups07AlarmDescr, ups07AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups07FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 6 }
|
|
|
|
ups07FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups07TestId, ups07TestSpinLock,
|
|
ups07TestResultsSummary, ups07TestResultsDetail,
|
|
ups07TestStartTime, ups07TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 7 }
|
|
|
|
ups07FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups07ShutdownType, ups07ShutdownAfterDelay,
|
|
ups07StartupAfterDelay, ups07RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups07FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups07FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 8 data
|
|
--
|
|
|
|
upsModule8 OBJECT IDENTIFIER ::= { upsModular 9 }
|
|
ups08Objects OBJECT IDENTIFIER ::= { upsModule8 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups08IdentName and
|
|
-- ups08IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups08Ident OBJECT IDENTIFIER ::= { ups08Objects 1 }
|
|
|
|
ups08IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups08Ident 1 }
|
|
|
|
ups08IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups08Ident 2 }
|
|
|
|
ups08IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups08IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups08Ident 3 }
|
|
|
|
ups08IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups08IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups08Ident 4 }
|
|
|
|
ups08IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups08Ident 5 }
|
|
|
|
ups08IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups08Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups08Battery OBJECT IDENTIFIER ::= { ups08Objects 2 }
|
|
|
|
ups08BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups08ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups08ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups08Battery 1 }
|
|
|
|
ups08SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups08Battery 2 }
|
|
|
|
ups08EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups08Battery 3 }
|
|
|
|
ups08EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups08Battery 4 }
|
|
|
|
ups08BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups08Battery 5 }
|
|
|
|
ups08BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups08Battery 6 }
|
|
|
|
ups08BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups08Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups08Input OBJECT IDENTIFIER ::= { ups08Objects 3 }
|
|
|
|
ups08InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups08Input 1 }
|
|
|
|
|
|
ups08InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups08Input 2 }
|
|
|
|
ups08InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups08InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups08InputNumLines."
|
|
::= { ups08Input 3 }
|
|
|
|
ups08InputEntry OBJECT-TYPE
|
|
SYNTAX Ups08InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups08InputLineIndex }
|
|
::= { ups08InputTable 1 }
|
|
|
|
Ups08InputEntry ::= SEQUENCE {
|
|
ups08InputLineIndex PositiveInteger,
|
|
ups08InputFrequency NonNegativeInteger,
|
|
ups08InputVoltage NonNegativeInteger,
|
|
ups08InputCurrent NonNegativeInteger,
|
|
ups08InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups08InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups08InputEntry 1 }
|
|
|
|
ups08InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups08InputEntry 2 }
|
|
|
|
ups08InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups08InputEntry 3 }
|
|
|
|
ups08InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups08InputEntry 4 }
|
|
|
|
ups08InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups08InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups08Output OBJECT IDENTIFIER ::= { ups08Objects 4 }
|
|
|
|
ups08OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups08Output 1 }
|
|
|
|
ups08OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups08Output 2 }
|
|
|
|
ups08OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups08Output 3 }
|
|
|
|
ups08OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups08OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups08OutputNumLines."
|
|
::= { ups08Output 4 }
|
|
|
|
ups08OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups08OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups08OutputLineIndex }
|
|
::= { ups08OutputTable 1 }
|
|
|
|
Ups08OutputEntry ::= SEQUENCE {
|
|
ups08OutputLineIndex PositiveInteger,
|
|
ups08OutputVoltage NonNegativeInteger,
|
|
ups08OutputCurrent NonNegativeInteger,
|
|
ups08OutputPower NonNegativeInteger,
|
|
ups08OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups08OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups08OutputEntry 1 }
|
|
|
|
ups08OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups08OutputEntry 2 }
|
|
|
|
ups08OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups08OutputEntry 3 }
|
|
|
|
ups08OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups08OutputEntry 4 }
|
|
|
|
ups08OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups08OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups08Bypass OBJECT IDENTIFIER ::= { ups08Objects 5 }
|
|
|
|
ups08BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups08Bypass 1 }
|
|
|
|
ups08BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups08Bypass 2 }
|
|
|
|
ups08BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups08BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups08BypassNumLines."
|
|
::= { ups08Bypass 3 }
|
|
|
|
ups08BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups08BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups08BypassLineIndex }
|
|
::= { ups08BypassTable 1 }
|
|
|
|
Ups08BypassEntry ::= SEQUENCE {
|
|
ups08BypassLineIndex PositiveInteger,
|
|
ups08BypassVoltage NonNegativeInteger,
|
|
ups08BypassCurrent NonNegativeInteger,
|
|
ups08BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups08BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups08BypassEntry 1 }
|
|
|
|
ups08BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups08BypassEntry 2 }
|
|
|
|
ups08BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups08BypassEntry 3 }
|
|
|
|
ups08BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups08BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups08Alarm OBJECT IDENTIFIER ::= { ups08Objects 6 }
|
|
|
|
ups08AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups08Alarm 1 }
|
|
|
|
ups08AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups08AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups08AlarmId equal to 1, and increments the value of
|
|
ups08AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups08AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups08AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups08AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups08AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups08AlarmsPresent."
|
|
::= { ups08Alarm 2 }
|
|
|
|
ups08AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups08AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups08AlarmId }
|
|
::= { ups08AlarmTable 1 }
|
|
|
|
Ups08AlarmEntry ::= SEQUENCE {
|
|
ups08AlarmId PositiveInteger,
|
|
ups08AlarmDescr AutonomousType,
|
|
ups08AlarmTime TimeStamp
|
|
}
|
|
|
|
ups08AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups08AlarmEntry 1 }
|
|
|
|
ups08AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups08AlarmEntry 2 }
|
|
|
|
ups08AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups08AlarmTime shall equal
|
|
0."
|
|
::= { ups08AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups08WellKnownAlarms OBJECT IDENTIFIER ::= { ups08Alarm 3 }
|
|
ups08AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups08WellKnownAlarms 1 }
|
|
|
|
ups08AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups08WellKnownAlarms 2 }
|
|
|
|
ups08AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups08ConfigLowBattTime."
|
|
::= { ups08WellKnownAlarms 3 }
|
|
|
|
|
|
ups08AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups08WellKnownAlarms 4 }
|
|
|
|
ups08AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups08WellKnownAlarms 5 }
|
|
|
|
ups08AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups08WellKnownAlarms 6 }
|
|
|
|
ups08AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups08WellKnownAlarms 7 }
|
|
|
|
ups08AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups08WellKnownAlarms 8 }
|
|
|
|
ups08AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups08WellKnownAlarms 9 }
|
|
|
|
ups08AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups08WellKnownAlarms 10 }
|
|
|
|
ups08AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups08WellKnownAlarms 11 }
|
|
|
|
ups08AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups08WellKnownAlarms 12 }
|
|
|
|
ups08AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups08WellKnownAlarms 13 }
|
|
|
|
ups08AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups08WellKnownAlarms 14 }
|
|
|
|
ups08AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups08WellKnownAlarms 15 }
|
|
|
|
ups08AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups08WellKnownAlarms 16 }
|
|
|
|
ups08AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups08WellKnownAlarms 17 }
|
|
|
|
ups08AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups08WellKnownAlarms 18 }
|
|
|
|
ups08AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups08WellKnownAlarms 19 }
|
|
|
|
ups08AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups08WellKnownAlarms 20 }
|
|
|
|
ups08AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups08WellKnownAlarms 21 }
|
|
|
|
ups08AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups08ShutdownAfterDelay countdown is underway."
|
|
::= { ups08WellKnownAlarms 22 }
|
|
|
|
ups08AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups08WellKnownAlarms 23 }
|
|
|
|
ups08AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups08WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups08Test OBJECT IDENTIFIER ::= { ups08Objects 7 }
|
|
|
|
ups08TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups08TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups08TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups08TestId variable to
|
|
ups08TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups08TestNoTestsInitiated is returned."
|
|
::= { ups08Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups08TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups08TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups08TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups08TestResultsSummary */
|
|
get (upsTestSpinLock, ups08TestResultsSummary,
|
|
ups08TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups08TestResultsSummary,
|
|
ups08TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups08TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups08TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups08Test 2 }
|
|
|
|
ups08TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups08TestId to ups08TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups08Test 3 }
|
|
|
|
ups08TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups08TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups08Test 4 }
|
|
|
|
ups08TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups08TestResultsSummary is noTestsInitiated(6),
|
|
ups08TestStartTime has the value 0."
|
|
::= { ups08Test 5 }
|
|
|
|
ups08TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups08TestResultsSummary is noTestsInitiated(6),
|
|
ups08TestElapsedTime has the value 0."
|
|
::= { ups08Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups08WellKnownTests OBJECT IDENTIFIER ::= { ups08Test 7 }
|
|
|
|
|
|
ups08TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups08WellKnownTests 1 }
|
|
|
|
ups08TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups08WellKnownTests 2 }
|
|
|
|
ups08TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups08WellKnownTests 3 }
|
|
|
|
ups08TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups08WellKnownTests 4 }
|
|
|
|
ups08TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups08WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups08Control OBJECT IDENTIFIER ::= { ups08Objects 8 }
|
|
|
|
ups08ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups08ShutdownAfterDelay and ups08RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups08Control 1 }
|
|
|
|
ups08ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups08ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups08ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups08ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups08ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups08ShutdownAfterDelay already in effect."
|
|
::= { ups08Control 2 }
|
|
|
|
ups08StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups08StartupAfterDelay
|
|
countdown or ups08RebootWithDuration countdown in
|
|
progress. When read, ups08StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups08Control 3 }
|
|
|
|
ups08RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups08ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups08RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups08Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups08Traps OBJECT IDENTIFIER ::= { upsModule8 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups08TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups08EstimatedMinutesRemaining, ups08SecondsOnBattery,
|
|
ups08ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups08Traps 1 }
|
|
|
|
ups08TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups08TestId, ups08TestSpinLock,
|
|
ups08TestResultsSummary, ups08TestResultsDetail,
|
|
ups08TestStartTime, ups08TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups08Traps 2 }
|
|
|
|
ups08TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups08AlarmId, ups08AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups08AlarmOnBattery and
|
|
ups08AlarmTestInProgress."
|
|
::= { ups08Traps 3 }
|
|
|
|
ups08TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups08AlarmId, ups08AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups08AlarmTestInProgress."
|
|
::= { ups08Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups08Conformance OBJECT IDENTIFIER ::= { upsModule8 3 }
|
|
|
|
ups08Compliances OBJECT IDENTIFIER ::= { ups08Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups08SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups08SubsetIdentGroup,
|
|
ups08SubsetBatteryGroup, ups08SubsetInputGroup,
|
|
ups08SubsetOutputGroup, ups08SubsetAlarmGroup,
|
|
ups08SubsetControlGroup }
|
|
|
|
OBJECT ups08BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups08AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups08AlarmOnBattery, ups08AlarmLowBattery,
|
|
ups08AlarmInputBad, ups08AlarmUpsOutputOff,
|
|
ups08AlarmUpsSystemOff, and ups08AlarmTestInProgress."
|
|
|
|
OBJECT ups08OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups08ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups08Compliances 1 }
|
|
|
|
ups08BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups08BasicIdentGroup,
|
|
ups08BasicBatteryGroup, ups08BasicInputGroup,
|
|
ups08BasicOutputGroup, ups08BasicAlarmGroup,
|
|
ups08BasicTestGroup, ups08BasicControlGroup }
|
|
|
|
|
|
OBJECT ups08AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups08AlarmOnBattery, ups08AlarmLowBattery,
|
|
ups08AlarmDepletedBattery, ups08AlarmTempBad,
|
|
ups08AlarmInputBad, ups08AlarmOutputOverload,
|
|
ups08AlarmOnBypass, ups08AlarmBypassBad,
|
|
ups08AlarmOutputOffAsRequested,
|
|
ups08AlarmUpsOffAsRequested, ups08AlarmUpsOutputOff,
|
|
ups08AlarmUpsSystemOff, ups08AlarmGeneralFault,
|
|
ups08AlarmDiagnosticTestFailed,
|
|
ups08AlarmCommunicationsLost, ups08AlarmShutdownPending,
|
|
and ups08AlarmTestInProgress."
|
|
|
|
OBJECT ups08TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups08TestNoTestsInitiated."
|
|
|
|
OBJECT ups08OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups08BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups08BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups08ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups08Compliances 2 }
|
|
|
|
ups08FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups08FullIdentGroup, ups08FullBatteryGroup,
|
|
ups08FullInputGroup, ups08FullOutputGroup,
|
|
ups08FullAlarmGroup, ups08FullTestGroup,
|
|
ups08FullControlGroup }
|
|
|
|
OBJECT ups08AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups08AlarmBatteryBad, ups08AlarmOnBattery,
|
|
ups08AlarmLowBattery, ups08AlarmDepletedBattery,
|
|
ups08AlarmTempBad, ups08AlarmInputBad, ups08AlarmOnBypass,
|
|
ups08AlarmBypassBad, ups08AlarmOutputOffAsRequested,
|
|
ups08AlarmUpsOffAsRequested, ups08AlarmUpsOutputOff,
|
|
ups08AlarmUpsSystemOff, ups08AlarmGeneralFault,
|
|
ups08AlarmDiagnosticTestFailed,
|
|
ups08AlarmCommunicationsLost, ups08AlarmShutdownPending,
|
|
and ups08AlarmTestInProgress."
|
|
|
|
OBJECT ups08TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups08TestNoTestsInitiated,
|
|
ups08TestGeneralSystemsTest, and
|
|
ups08TestQuickBatteryTest."
|
|
|
|
OBJECT ups08OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups08FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups08FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups08ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups08Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups08Groups OBJECT IDENTIFIER ::= { ups08Conformance 2 }
|
|
|
|
ups08SubsetGroups OBJECT IDENTIFIER ::= { ups08Groups 1 }
|
|
|
|
ups08SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups08IdentManufacturer, ups08IdentModel,
|
|
ups08IdentAgentSoftwareVersion, ups08IdentName,
|
|
ups08IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups08SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups08SubsetGroups 1 }
|
|
|
|
ups08SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups08BatteryStatus, ups08SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups08SubsetGroups 2 }
|
|
|
|
ups08SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups08InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups08SubsetGroups 3 }
|
|
|
|
ups08SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups08OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups08SubsetGroups 4 }
|
|
|
|
|
|
-- { ups08SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups08SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups08AlarmsPresent, ups08AlarmDescr, ups08AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups08SubsetGroups 6 }
|
|
|
|
-- { ups08SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups08SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups08ShutdownType, ups08ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups08SubsetGroups 8 }
|
|
|
|
ups08BasicGroups OBJECT IDENTIFIER ::= { ups08Groups 2 }
|
|
|
|
ups08BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups08IdentManufacturer, ups08IdentModel,
|
|
ups08IdentUPSSoftwareVersion,
|
|
ups08IdentAgentSoftwareVersion, ups08IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 1 }
|
|
|
|
ups08BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups08BatteryStatus, ups08SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 2 }
|
|
|
|
ups08BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups08InputLineBads, ups08InputNumLines,
|
|
ups08InputFrequency, ups08InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 3 }
|
|
|
|
ups08BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups08OutputSource, ups08OutputFrequency,
|
|
ups08OutputNumLines, ups08OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 4 }
|
|
|
|
ups08BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups08BypassFrequency, ups08BypassNumLines,
|
|
ups08BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 5 }
|
|
|
|
ups08BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups08AlarmsPresent, ups08AlarmDescr, ups08AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups08BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 6 }
|
|
|
|
ups08BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups08TestId, ups08TestSpinLock,
|
|
ups08TestResultsSummary, ups08TestResultsDetail,
|
|
ups08TestStartTime, ups08TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 7 }
|
|
|
|
ups08BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups08ShutdownType, ups08ShutdownAfterDelay,
|
|
ups08StartupAfterDelay, ups08RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups08BasicGroups 8 }
|
|
|
|
ups08FullGroups OBJECT IDENTIFIER ::= { ups08Groups 3 }
|
|
|
|
ups08FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups08IdentManufacturer, ups08IdentModel,
|
|
ups08IdentUPSSoftwareVersion,
|
|
ups08IdentAgentSoftwareVersion, ups08IdentName,
|
|
ups08IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups08FullGroups 1 }
|
|
|
|
ups08FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups08BatteryStatus, ups08SecondsOnBattery,
|
|
ups08EstimatedMinutesRemaining,
|
|
ups08EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 2 }
|
|
|
|
ups08FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups08InputLineBads, ups08InputNumLines,
|
|
ups08InputFrequency, ups08InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 3 }
|
|
|
|
ups08FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups08OutputSource, ups08OutputFrequency,
|
|
ups08OutputNumLines, ups08OutputVoltage,
|
|
ups08OutputCurrent, ups08OutputPower,
|
|
ups08OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 4 }
|
|
|
|
ups08FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups08BypassFrequency, ups08BypassNumLines,
|
|
ups08BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 5 }
|
|
|
|
ups08FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups08AlarmsPresent, ups08AlarmDescr, ups08AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups08FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 6 }
|
|
|
|
ups08FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups08TestId, ups08TestSpinLock,
|
|
ups08TestResultsSummary, ups08TestResultsDetail,
|
|
ups08TestStartTime, ups08TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 7 }
|
|
|
|
ups08FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups08ShutdownType, ups08ShutdownAfterDelay,
|
|
ups08StartupAfterDelay, ups08RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups08FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups08FullGroups 8 }
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 9 data
|
|
--
|
|
|
|
upsModule9 OBJECT IDENTIFIER ::= { upsModular 10 }
|
|
ups09Objects OBJECT IDENTIFIER ::= { upsModule9 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups09IdentName and
|
|
-- ups09IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups09Ident OBJECT IDENTIFIER ::= { ups09Objects 1 }
|
|
|
|
ups09IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups09Ident 1 }
|
|
|
|
ups09IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups09Ident 2 }
|
|
|
|
ups09IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups09IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups09Ident 3 }
|
|
|
|
ups09IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups09IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups09Ident 4 }
|
|
|
|
ups09IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups09Ident 5 }
|
|
|
|
ups09IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups09Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups09Battery OBJECT IDENTIFIER ::= { ups09Objects 2 }
|
|
|
|
ups09BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups09ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups09ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups09Battery 1 }
|
|
|
|
ups09SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups09Battery 2 }
|
|
|
|
ups09EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups09Battery 3 }
|
|
|
|
ups09EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups09Battery 4 }
|
|
|
|
ups09BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups09Battery 5 }
|
|
|
|
ups09BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups09Battery 6 }
|
|
|
|
ups09BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups09Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups09Input OBJECT IDENTIFIER ::= { ups09Objects 3 }
|
|
|
|
ups09InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups09Input 1 }
|
|
|
|
|
|
ups09InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups09Input 2 }
|
|
|
|
ups09InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups09InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups09InputNumLines."
|
|
::= { ups09Input 3 }
|
|
|
|
ups09InputEntry OBJECT-TYPE
|
|
SYNTAX Ups09InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups09InputLineIndex }
|
|
::= { ups09InputTable 1 }
|
|
|
|
Ups09InputEntry ::= SEQUENCE {
|
|
ups09InputLineIndex PositiveInteger,
|
|
ups09InputFrequency NonNegativeInteger,
|
|
ups09InputVoltage NonNegativeInteger,
|
|
ups09InputCurrent NonNegativeInteger,
|
|
ups09InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups09InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups09InputEntry 1 }
|
|
|
|
ups09InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups09InputEntry 2 }
|
|
|
|
ups09InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups09InputEntry 3 }
|
|
|
|
ups09InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups09InputEntry 4 }
|
|
|
|
ups09InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups09InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups09Output OBJECT IDENTIFIER ::= { ups09Objects 4 }
|
|
|
|
ups09OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups09Output 1 }
|
|
|
|
ups09OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups09Output 2 }
|
|
|
|
ups09OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups09Output 3 }
|
|
|
|
ups09OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups09OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups09OutputNumLines."
|
|
::= { ups09Output 4 }
|
|
|
|
ups09OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups09OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups09OutputLineIndex }
|
|
::= { ups09OutputTable 1 }
|
|
|
|
Ups09OutputEntry ::= SEQUENCE {
|
|
ups09OutputLineIndex PositiveInteger,
|
|
ups09OutputVoltage NonNegativeInteger,
|
|
ups09OutputCurrent NonNegativeInteger,
|
|
ups09OutputPower NonNegativeInteger,
|
|
ups09OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups09OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups09OutputEntry 1 }
|
|
|
|
ups09OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups09OutputEntry 2 }
|
|
|
|
ups09OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups09OutputEntry 3 }
|
|
|
|
ups09OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups09OutputEntry 4 }
|
|
|
|
ups09OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups09OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups09Bypass OBJECT IDENTIFIER ::= { ups09Objects 5 }
|
|
|
|
ups09BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups09Bypass 1 }
|
|
|
|
ups09BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups09Bypass 2 }
|
|
|
|
ups09BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups09BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups09BypassNumLines."
|
|
::= { ups09Bypass 3 }
|
|
|
|
ups09BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups09BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups09BypassLineIndex }
|
|
::= { ups09BypassTable 1 }
|
|
|
|
Ups09BypassEntry ::= SEQUENCE {
|
|
ups09BypassLineIndex PositiveInteger,
|
|
ups09BypassVoltage NonNegativeInteger,
|
|
ups09BypassCurrent NonNegativeInteger,
|
|
ups09BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups09BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups09BypassEntry 1 }
|
|
|
|
ups09BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups09BypassEntry 2 }
|
|
|
|
ups09BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups09BypassEntry 3 }
|
|
|
|
ups09BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups09BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups09Alarm OBJECT IDENTIFIER ::= { ups09Objects 6 }
|
|
|
|
ups09AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups09Alarm 1 }
|
|
|
|
ups09AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups09AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups09AlarmId equal to 1, and increments the value of
|
|
ups09AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups09AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups09AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups09AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups09AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups09AlarmsPresent."
|
|
::= { ups09Alarm 2 }
|
|
|
|
ups09AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups09AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups09AlarmId }
|
|
::= { ups09AlarmTable 1 }
|
|
|
|
Ups09AlarmEntry ::= SEQUENCE {
|
|
ups09AlarmId PositiveInteger,
|
|
ups09AlarmDescr AutonomousType,
|
|
ups09AlarmTime TimeStamp
|
|
}
|
|
|
|
ups09AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups09AlarmEntry 1 }
|
|
|
|
ups09AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups09AlarmEntry 2 }
|
|
|
|
ups09AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups09AlarmTime shall equal
|
|
0."
|
|
::= { ups09AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups09WellKnownAlarms OBJECT IDENTIFIER ::= { ups09Alarm 3 }
|
|
ups09AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups09WellKnownAlarms 1 }
|
|
|
|
ups09AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups09WellKnownAlarms 2 }
|
|
|
|
ups09AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups09ConfigLowBattTime."
|
|
::= { ups09WellKnownAlarms 3 }
|
|
|
|
|
|
ups09AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups09WellKnownAlarms 4 }
|
|
|
|
ups09AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups09WellKnownAlarms 5 }
|
|
|
|
ups09AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups09WellKnownAlarms 6 }
|
|
|
|
ups09AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups09WellKnownAlarms 7 }
|
|
|
|
ups09AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups09WellKnownAlarms 8 }
|
|
|
|
ups09AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups09WellKnownAlarms 9 }
|
|
|
|
ups09AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups09WellKnownAlarms 10 }
|
|
|
|
ups09AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups09WellKnownAlarms 11 }
|
|
|
|
ups09AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups09WellKnownAlarms 12 }
|
|
|
|
ups09AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups09WellKnownAlarms 13 }
|
|
|
|
ups09AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups09WellKnownAlarms 14 }
|
|
|
|
ups09AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups09WellKnownAlarms 15 }
|
|
|
|
ups09AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups09WellKnownAlarms 16 }
|
|
|
|
ups09AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups09WellKnownAlarms 17 }
|
|
|
|
ups09AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups09WellKnownAlarms 18 }
|
|
|
|
ups09AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups09WellKnownAlarms 19 }
|
|
|
|
ups09AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups09WellKnownAlarms 20 }
|
|
|
|
ups09AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups09WellKnownAlarms 21 }
|
|
|
|
ups09AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups09ShutdownAfterDelay countdown is underway."
|
|
::= { ups09WellKnownAlarms 22 }
|
|
|
|
ups09AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups09WellKnownAlarms 23 }
|
|
|
|
ups09AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups09WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups09Test OBJECT IDENTIFIER ::= { ups09Objects 7 }
|
|
|
|
ups09TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups09TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups09TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups09TestId variable to
|
|
ups09TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups09TestNoTestsInitiated is returned."
|
|
::= { ups09Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups09TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups09TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups09TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups09TestResultsSummary */
|
|
get (upsTestSpinLock, ups09TestResultsSummary,
|
|
ups09TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups09TestResultsSummary,
|
|
ups09TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups09TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups09TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups09Test 2 }
|
|
|
|
ups09TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups09TestId to ups09TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups09Test 3 }
|
|
|
|
ups09TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups09TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups09Test 4 }
|
|
|
|
ups09TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups09TestResultsSummary is noTestsInitiated(6),
|
|
ups09TestStartTime has the value 0."
|
|
::= { ups09Test 5 }
|
|
|
|
ups09TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups09TestResultsSummary is noTestsInitiated(6),
|
|
ups09TestElapsedTime has the value 0."
|
|
::= { ups09Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups09WellKnownTests OBJECT IDENTIFIER ::= { ups09Test 7 }
|
|
|
|
|
|
ups09TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups09WellKnownTests 1 }
|
|
|
|
ups09TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups09WellKnownTests 2 }
|
|
|
|
ups09TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups09WellKnownTests 3 }
|
|
|
|
ups09TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups09WellKnownTests 4 }
|
|
|
|
ups09TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups09WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups09Control OBJECT IDENTIFIER ::= { ups09Objects 8 }
|
|
|
|
ups09ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups09ShutdownAfterDelay and ups09RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups09Control 1 }
|
|
|
|
ups09ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups09ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups09ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups09ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups09ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups09ShutdownAfterDelay already in effect."
|
|
::= { ups09Control 2 }
|
|
|
|
ups09StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups09StartupAfterDelay
|
|
countdown or ups09RebootWithDuration countdown in
|
|
progress. When read, ups09StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups09Control 3 }
|
|
|
|
ups09RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups09ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups09RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups09Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups09Traps OBJECT IDENTIFIER ::= { upsModule9 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups09TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups09EstimatedMinutesRemaining, ups09SecondsOnBattery,
|
|
ups09ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups09Traps 1 }
|
|
|
|
ups09TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups09TestId, ups09TestSpinLock,
|
|
ups09TestResultsSummary, ups09TestResultsDetail,
|
|
ups09TestStartTime, ups09TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups09Traps 2 }
|
|
|
|
ups09TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups09AlarmId, ups09AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups09AlarmOnBattery and
|
|
ups09AlarmTestInProgress."
|
|
::= { ups09Traps 3 }
|
|
|
|
ups09TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups09AlarmId, ups09AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups09AlarmTestInProgress."
|
|
::= { ups09Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups09Conformance OBJECT IDENTIFIER ::= { upsModule9 3 }
|
|
|
|
ups09Compliances OBJECT IDENTIFIER ::= { ups09Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups09SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups09SubsetIdentGroup,
|
|
ups09SubsetBatteryGroup, ups09SubsetInputGroup,
|
|
ups09SubsetOutputGroup, ups09SubsetAlarmGroup,
|
|
ups09SubsetControlGroup }
|
|
|
|
OBJECT ups09BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups09AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups09AlarmOnBattery, ups09AlarmLowBattery,
|
|
ups09AlarmInputBad, ups09AlarmUpsOutputOff,
|
|
ups09AlarmUpsSystemOff, and ups09AlarmTestInProgress."
|
|
|
|
OBJECT ups09OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups09ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups09Compliances 1 }
|
|
|
|
ups09BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups09BasicIdentGroup,
|
|
ups09BasicBatteryGroup, ups09BasicInputGroup,
|
|
ups09BasicOutputGroup, ups09BasicAlarmGroup,
|
|
ups09BasicTestGroup, ups09BasicControlGroup }
|
|
|
|
|
|
OBJECT ups09AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups09AlarmOnBattery, ups09AlarmLowBattery,
|
|
ups09AlarmDepletedBattery, ups09AlarmTempBad,
|
|
ups09AlarmInputBad, ups09AlarmOutputOverload,
|
|
ups09AlarmOnBypass, ups09AlarmBypassBad,
|
|
ups09AlarmOutputOffAsRequested,
|
|
ups09AlarmUpsOffAsRequested, ups09AlarmUpsOutputOff,
|
|
ups09AlarmUpsSystemOff, ups09AlarmGeneralFault,
|
|
ups09AlarmDiagnosticTestFailed,
|
|
ups09AlarmCommunicationsLost, ups09AlarmShutdownPending,
|
|
and ups09AlarmTestInProgress."
|
|
|
|
OBJECT ups09TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups09TestNoTestsInitiated."
|
|
|
|
OBJECT ups09OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups09BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups09BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups09ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups09Compliances 2 }
|
|
|
|
ups09FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups09FullIdentGroup, ups09FullBatteryGroup,
|
|
ups09FullInputGroup, ups09FullOutputGroup,
|
|
ups09FullAlarmGroup, ups09FullTestGroup,
|
|
ups09FullControlGroup }
|
|
|
|
OBJECT ups09AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups09AlarmBatteryBad, ups09AlarmOnBattery,
|
|
ups09AlarmLowBattery, ups09AlarmDepletedBattery,
|
|
ups09AlarmTempBad, ups09AlarmInputBad, ups09AlarmOnBypass,
|
|
ups09AlarmBypassBad, ups09AlarmOutputOffAsRequested,
|
|
ups09AlarmUpsOffAsRequested, ups09AlarmUpsOutputOff,
|
|
ups09AlarmUpsSystemOff, ups09AlarmGeneralFault,
|
|
ups09AlarmDiagnosticTestFailed,
|
|
ups09AlarmCommunicationsLost, ups09AlarmShutdownPending,
|
|
and ups09AlarmTestInProgress."
|
|
|
|
OBJECT ups09TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups09TestNoTestsInitiated,
|
|
ups09TestGeneralSystemsTest, and
|
|
ups09TestQuickBatteryTest."
|
|
|
|
OBJECT ups09OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups09FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups09FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups09ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups09Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups09Groups OBJECT IDENTIFIER ::= { ups09Conformance 2 }
|
|
|
|
ups09SubsetGroups OBJECT IDENTIFIER ::= { ups09Groups 1 }
|
|
|
|
ups09SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups09IdentManufacturer, ups09IdentModel,
|
|
ups09IdentAgentSoftwareVersion, ups09IdentName,
|
|
ups09IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups09SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups09SubsetGroups 1 }
|
|
|
|
ups09SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups09BatteryStatus, ups09SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups09SubsetGroups 2 }
|
|
|
|
ups09SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups09InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups09SubsetGroups 3 }
|
|
|
|
ups09SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups09OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups09SubsetGroups 4 }
|
|
|
|
|
|
-- { ups09SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups09SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups09AlarmsPresent, ups09AlarmDescr, ups09AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups09SubsetGroups 6 }
|
|
|
|
-- { ups09SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups09SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups09ShutdownType, ups09ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups09SubsetGroups 8 }
|
|
|
|
ups09BasicGroups OBJECT IDENTIFIER ::= { ups09Groups 2 }
|
|
|
|
ups09BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups09IdentManufacturer, ups09IdentModel,
|
|
ups09IdentUPSSoftwareVersion,
|
|
ups09IdentAgentSoftwareVersion, ups09IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 1 }
|
|
|
|
ups09BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups09BatteryStatus, ups09SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 2 }
|
|
|
|
ups09BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups09InputLineBads, ups09InputNumLines,
|
|
ups09InputFrequency, ups09InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 3 }
|
|
|
|
ups09BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups09OutputSource, ups09OutputFrequency,
|
|
ups09OutputNumLines, ups09OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 4 }
|
|
|
|
ups09BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups09BypassFrequency, ups09BypassNumLines,
|
|
ups09BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 5 }
|
|
|
|
ups09BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups09AlarmsPresent, ups09AlarmDescr, ups09AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups09BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 6 }
|
|
|
|
ups09BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups09TestId, ups09TestSpinLock,
|
|
ups09TestResultsSummary, ups09TestResultsDetail,
|
|
ups09TestStartTime, ups09TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 7 }
|
|
|
|
ups09BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups09ShutdownType, ups09ShutdownAfterDelay,
|
|
ups09StartupAfterDelay, ups09RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups09BasicGroups 8 }
|
|
|
|
ups09FullGroups OBJECT IDENTIFIER ::= { ups09Groups 3 }
|
|
|
|
ups09FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups09IdentManufacturer, ups09IdentModel,
|
|
ups09IdentUPSSoftwareVersion,
|
|
ups09IdentAgentSoftwareVersion, ups09IdentName,
|
|
ups09IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups09FullGroups 1 }
|
|
|
|
ups09FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups09BatteryStatus, ups09SecondsOnBattery,
|
|
ups09EstimatedMinutesRemaining,
|
|
ups09EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 2 }
|
|
|
|
ups09FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups09InputLineBads, ups09InputNumLines,
|
|
ups09InputFrequency, ups09InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 3 }
|
|
|
|
ups09FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups09OutputSource, ups09OutputFrequency,
|
|
ups09OutputNumLines, ups09OutputVoltage,
|
|
ups09OutputCurrent, ups09OutputPower,
|
|
ups09OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 4 }
|
|
|
|
ups09FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups09BypassFrequency, ups09BypassNumLines,
|
|
ups09BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 5 }
|
|
|
|
ups09FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups09AlarmsPresent, ups09AlarmDescr, ups09AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups09FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 6 }
|
|
|
|
ups09FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups09TestId, ups09TestSpinLock,
|
|
ups09TestResultsSummary, ups09TestResultsDetail,
|
|
ups09TestStartTime, ups09TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 7 }
|
|
|
|
ups09FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups09ShutdownType, ups09ShutdownAfterDelay,
|
|
ups09StartupAfterDelay, ups09RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups09FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups09FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 10 data
|
|
--
|
|
|
|
upsModule10 OBJECT IDENTIFIER ::= { upsModular 11 }
|
|
ups10Objects OBJECT IDENTIFIER ::= { upsModule10 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups10IdentName and
|
|
-- ups10IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups10Ident OBJECT IDENTIFIER ::= { ups10Objects 1 }
|
|
|
|
ups10IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups10Ident 1 }
|
|
|
|
ups10IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups10Ident 2 }
|
|
|
|
ups10IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups10IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups10Ident 3 }
|
|
|
|
ups10IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups10IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups10Ident 4 }
|
|
|
|
ups10IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups10Ident 5 }
|
|
|
|
ups10IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups10Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups10Battery OBJECT IDENTIFIER ::= { ups10Objects 2 }
|
|
|
|
ups10BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups10ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups10ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups10Battery 1 }
|
|
|
|
ups10SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups10Battery 2 }
|
|
|
|
ups10EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups10Battery 3 }
|
|
|
|
ups10EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups10Battery 4 }
|
|
|
|
ups10BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups10Battery 5 }
|
|
|
|
ups10BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups10Battery 6 }
|
|
|
|
ups10BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups10Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups10Input OBJECT IDENTIFIER ::= { ups10Objects 3 }
|
|
|
|
ups10InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups10Input 1 }
|
|
|
|
|
|
ups10InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups10Input 2 }
|
|
|
|
ups10InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups10InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups10InputNumLines."
|
|
::= { ups10Input 3 }
|
|
|
|
ups10InputEntry OBJECT-TYPE
|
|
SYNTAX Ups10InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups10InputLineIndex }
|
|
::= { ups10InputTable 1 }
|
|
|
|
Ups10InputEntry ::= SEQUENCE {
|
|
ups10InputLineIndex PositiveInteger,
|
|
ups10InputFrequency NonNegativeInteger,
|
|
ups10InputVoltage NonNegativeInteger,
|
|
ups10InputCurrent NonNegativeInteger,
|
|
ups10InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups10InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups10InputEntry 1 }
|
|
|
|
ups10InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups10InputEntry 2 }
|
|
|
|
ups10InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups10InputEntry 3 }
|
|
|
|
ups10InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups10InputEntry 4 }
|
|
|
|
ups10InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups10InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups10Output OBJECT IDENTIFIER ::= { ups10Objects 4 }
|
|
|
|
ups10OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups10Output 1 }
|
|
|
|
ups10OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups10Output 2 }
|
|
|
|
ups10OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups10Output 3 }
|
|
|
|
ups10OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups10OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups10OutputNumLines."
|
|
::= { ups10Output 4 }
|
|
|
|
ups10OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups10OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups10OutputLineIndex }
|
|
::= { ups10OutputTable 1 }
|
|
|
|
Ups10OutputEntry ::= SEQUENCE {
|
|
ups10OutputLineIndex PositiveInteger,
|
|
ups10OutputVoltage NonNegativeInteger,
|
|
ups10OutputCurrent NonNegativeInteger,
|
|
ups10OutputPower NonNegativeInteger,
|
|
ups10OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups10OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups10OutputEntry 1 }
|
|
|
|
ups10OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups10OutputEntry 2 }
|
|
|
|
ups10OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups10OutputEntry 3 }
|
|
|
|
ups10OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups10OutputEntry 4 }
|
|
|
|
ups10OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups10OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups10Bypass OBJECT IDENTIFIER ::= { ups10Objects 5 }
|
|
|
|
ups10BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups10Bypass 1 }
|
|
|
|
ups10BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups10Bypass 2 }
|
|
|
|
ups10BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups10BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups10BypassNumLines."
|
|
::= { ups10Bypass 3 }
|
|
|
|
ups10BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups10BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups10BypassLineIndex }
|
|
::= { ups10BypassTable 1 }
|
|
|
|
Ups10BypassEntry ::= SEQUENCE {
|
|
ups10BypassLineIndex PositiveInteger,
|
|
ups10BypassVoltage NonNegativeInteger,
|
|
ups10BypassCurrent NonNegativeInteger,
|
|
ups10BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups10BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups10BypassEntry 1 }
|
|
|
|
ups10BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups10BypassEntry 2 }
|
|
|
|
ups10BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups10BypassEntry 3 }
|
|
|
|
ups10BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups10BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups10Alarm OBJECT IDENTIFIER ::= { ups10Objects 6 }
|
|
|
|
ups10AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups10Alarm 1 }
|
|
|
|
ups10AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups10AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups10AlarmId equal to 1, and increments the value of
|
|
ups10AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups10AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups10AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups10AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups10AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups10AlarmsPresent."
|
|
::= { ups10Alarm 2 }
|
|
|
|
ups10AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups10AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups10AlarmId }
|
|
::= { ups10AlarmTable 1 }
|
|
|
|
Ups10AlarmEntry ::= SEQUENCE {
|
|
ups10AlarmId PositiveInteger,
|
|
ups10AlarmDescr AutonomousType,
|
|
ups10AlarmTime TimeStamp
|
|
}
|
|
|
|
ups10AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups10AlarmEntry 1 }
|
|
|
|
ups10AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups10AlarmEntry 2 }
|
|
|
|
ups10AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups10AlarmTime shall equal
|
|
0."
|
|
::= { ups10AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups10WellKnownAlarms OBJECT IDENTIFIER ::= { ups10Alarm 3 }
|
|
ups10AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups10WellKnownAlarms 1 }
|
|
|
|
ups10AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups10WellKnownAlarms 2 }
|
|
|
|
ups10AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups10ConfigLowBattTime."
|
|
::= { ups10WellKnownAlarms 3 }
|
|
|
|
|
|
ups10AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups10WellKnownAlarms 4 }
|
|
|
|
ups10AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups10WellKnownAlarms 5 }
|
|
|
|
ups10AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups10WellKnownAlarms 6 }
|
|
|
|
ups10AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups10WellKnownAlarms 7 }
|
|
|
|
ups10AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups10WellKnownAlarms 8 }
|
|
|
|
ups10AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups10WellKnownAlarms 9 }
|
|
|
|
ups10AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups10WellKnownAlarms 10 }
|
|
|
|
ups10AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups10WellKnownAlarms 11 }
|
|
|
|
ups10AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups10WellKnownAlarms 12 }
|
|
|
|
ups10AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups10WellKnownAlarms 13 }
|
|
|
|
ups10AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups10WellKnownAlarms 14 }
|
|
|
|
ups10AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups10WellKnownAlarms 15 }
|
|
|
|
ups10AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups10WellKnownAlarms 16 }
|
|
|
|
ups10AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups10WellKnownAlarms 17 }
|
|
|
|
ups10AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups10WellKnownAlarms 18 }
|
|
|
|
ups10AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups10WellKnownAlarms 19 }
|
|
|
|
ups10AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups10WellKnownAlarms 20 }
|
|
|
|
ups10AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups10WellKnownAlarms 21 }
|
|
|
|
ups10AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups10ShutdownAfterDelay countdown is underway."
|
|
::= { ups10WellKnownAlarms 22 }
|
|
|
|
ups10AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups10WellKnownAlarms 23 }
|
|
|
|
ups10AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups10WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups10Test OBJECT IDENTIFIER ::= { ups10Objects 7 }
|
|
|
|
ups10TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups10TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups10TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups10TestId variable to
|
|
ups10TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups10TestNoTestsInitiated is returned."
|
|
::= { ups10Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups10TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups10TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups10TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups10TestResultsSummary */
|
|
get (upsTestSpinLock, ups10TestResultsSummary,
|
|
ups10TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups10TestResultsSummary,
|
|
ups10TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups10TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups10TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups10Test 2 }
|
|
|
|
ups10TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups10TestId to ups10TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups10Test 3 }
|
|
|
|
ups10TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups10TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups10Test 4 }
|
|
|
|
ups10TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups10TestResultsSummary is noTestsInitiated(6),
|
|
ups10TestStartTime has the value 0."
|
|
::= { ups10Test 5 }
|
|
|
|
ups10TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups10TestResultsSummary is noTestsInitiated(6),
|
|
ups10TestElapsedTime has the value 0."
|
|
::= { ups10Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups10WellKnownTests OBJECT IDENTIFIER ::= { ups10Test 7 }
|
|
|
|
|
|
ups10TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups10WellKnownTests 1 }
|
|
|
|
ups10TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups10WellKnownTests 2 }
|
|
|
|
ups10TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups10WellKnownTests 3 }
|
|
|
|
ups10TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups10WellKnownTests 4 }
|
|
|
|
ups10TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups10WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups10Control OBJECT IDENTIFIER ::= { ups10Objects 8 }
|
|
|
|
ups10ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups10ShutdownAfterDelay and ups10RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups10Control 1 }
|
|
|
|
ups10ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups10ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups10ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups10ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups10ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups10ShutdownAfterDelay already in effect."
|
|
::= { ups10Control 2 }
|
|
|
|
ups10StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups10StartupAfterDelay
|
|
countdown or ups10RebootWithDuration countdown in
|
|
progress. When read, ups10StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups10Control 3 }
|
|
|
|
ups10RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups10ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups10RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups10Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups10Traps OBJECT IDENTIFIER ::= { upsModule10 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups10TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups10EstimatedMinutesRemaining, ups10SecondsOnBattery,
|
|
ups10ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups10Traps 1 }
|
|
|
|
ups10TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups10TestId, ups10TestSpinLock,
|
|
ups10TestResultsSummary, ups10TestResultsDetail,
|
|
ups10TestStartTime, ups10TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups10Traps 2 }
|
|
|
|
ups10TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups10AlarmId, ups10AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups10AlarmOnBattery and
|
|
ups10AlarmTestInProgress."
|
|
::= { ups10Traps 3 }
|
|
|
|
ups10TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups10AlarmId, ups10AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups10AlarmTestInProgress."
|
|
::= { ups10Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups10Conformance OBJECT IDENTIFIER ::= { upsModule10 3 }
|
|
|
|
ups10Compliances OBJECT IDENTIFIER ::= { ups10Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups10SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups10SubsetIdentGroup,
|
|
ups10SubsetBatteryGroup, ups10SubsetInputGroup,
|
|
ups10SubsetOutputGroup, ups10SubsetAlarmGroup,
|
|
ups10SubsetControlGroup }
|
|
|
|
OBJECT ups10BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups10AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups10AlarmOnBattery, ups10AlarmLowBattery,
|
|
ups10AlarmInputBad, ups10AlarmUpsOutputOff,
|
|
ups10AlarmUpsSystemOff, and ups10AlarmTestInProgress."
|
|
|
|
OBJECT ups10OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups10ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups10Compliances 1 }
|
|
|
|
ups10BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups10BasicIdentGroup,
|
|
ups10BasicBatteryGroup, ups10BasicInputGroup,
|
|
ups10BasicOutputGroup, ups10BasicAlarmGroup,
|
|
ups10BasicTestGroup, ups10BasicControlGroup }
|
|
|
|
|
|
OBJECT ups10AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups10AlarmOnBattery, ups10AlarmLowBattery,
|
|
ups10AlarmDepletedBattery, ups10AlarmTempBad,
|
|
ups10AlarmInputBad, ups10AlarmOutputOverload,
|
|
ups10AlarmOnBypass, ups10AlarmBypassBad,
|
|
ups10AlarmOutputOffAsRequested,
|
|
ups10AlarmUpsOffAsRequested, ups10AlarmUpsOutputOff,
|
|
ups10AlarmUpsSystemOff, ups10AlarmGeneralFault,
|
|
ups10AlarmDiagnosticTestFailed,
|
|
ups10AlarmCommunicationsLost, ups10AlarmShutdownPending,
|
|
and ups10AlarmTestInProgress."
|
|
|
|
OBJECT ups10TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups10TestNoTestsInitiated."
|
|
|
|
OBJECT ups10OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups10BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups10BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups10ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups10Compliances 2 }
|
|
|
|
ups10FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups10FullIdentGroup, ups10FullBatteryGroup,
|
|
ups10FullInputGroup, ups10FullOutputGroup,
|
|
ups10FullAlarmGroup, ups10FullTestGroup,
|
|
ups10FullControlGroup }
|
|
|
|
OBJECT ups10AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups10AlarmBatteryBad, ups10AlarmOnBattery,
|
|
ups10AlarmLowBattery, ups10AlarmDepletedBattery,
|
|
ups10AlarmTempBad, ups10AlarmInputBad, ups10AlarmOnBypass,
|
|
ups10AlarmBypassBad, ups10AlarmOutputOffAsRequested,
|
|
ups10AlarmUpsOffAsRequested, ups10AlarmUpsOutputOff,
|
|
ups10AlarmUpsSystemOff, ups10AlarmGeneralFault,
|
|
ups10AlarmDiagnosticTestFailed,
|
|
ups10AlarmCommunicationsLost, ups10AlarmShutdownPending,
|
|
and ups10AlarmTestInProgress."
|
|
|
|
OBJECT ups10TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups10TestNoTestsInitiated,
|
|
ups10TestGeneralSystemsTest, and
|
|
ups10TestQuickBatteryTest."
|
|
|
|
OBJECT ups10OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups10FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups10FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups10ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups10Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups10Groups OBJECT IDENTIFIER ::= { ups10Conformance 2 }
|
|
|
|
ups10SubsetGroups OBJECT IDENTIFIER ::= { ups10Groups 1 }
|
|
|
|
ups10SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups10IdentManufacturer, ups10IdentModel,
|
|
ups10IdentAgentSoftwareVersion, ups10IdentName,
|
|
ups10IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups10SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups10SubsetGroups 1 }
|
|
|
|
ups10SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups10BatteryStatus, ups10SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups10SubsetGroups 2 }
|
|
|
|
ups10SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups10InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups10SubsetGroups 3 }
|
|
|
|
ups10SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups10OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups10SubsetGroups 4 }
|
|
|
|
|
|
-- { ups10SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups10SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups10AlarmsPresent, ups10AlarmDescr, ups10AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups10SubsetGroups 6 }
|
|
|
|
-- { ups10SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups10SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups10ShutdownType, ups10ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups10SubsetGroups 8 }
|
|
|
|
ups10BasicGroups OBJECT IDENTIFIER ::= { ups10Groups 2 }
|
|
|
|
ups10BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups10IdentManufacturer, ups10IdentModel,
|
|
ups10IdentUPSSoftwareVersion,
|
|
ups10IdentAgentSoftwareVersion, ups10IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 1 }
|
|
|
|
ups10BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups10BatteryStatus, ups10SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 2 }
|
|
|
|
ups10BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups10InputLineBads, ups10InputNumLines,
|
|
ups10InputFrequency, ups10InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 3 }
|
|
|
|
ups10BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups10OutputSource, ups10OutputFrequency,
|
|
ups10OutputNumLines, ups10OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 4 }
|
|
|
|
ups10BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups10BypassFrequency, ups10BypassNumLines,
|
|
ups10BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 5 }
|
|
|
|
ups10BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups10AlarmsPresent, ups10AlarmDescr, ups10AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups10BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 6 }
|
|
|
|
ups10BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups10TestId, ups10TestSpinLock,
|
|
ups10TestResultsSummary, ups10TestResultsDetail,
|
|
ups10TestStartTime, ups10TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 7 }
|
|
|
|
ups10BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups10ShutdownType, ups10ShutdownAfterDelay,
|
|
ups10StartupAfterDelay, ups10RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups10BasicGroups 8 }
|
|
|
|
ups10FullGroups OBJECT IDENTIFIER ::= { ups10Groups 3 }
|
|
|
|
ups10FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups10IdentManufacturer, ups10IdentModel,
|
|
ups10IdentUPSSoftwareVersion,
|
|
ups10IdentAgentSoftwareVersion, ups10IdentName,
|
|
ups10IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups10FullGroups 1 }
|
|
|
|
ups10FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups10BatteryStatus, ups10SecondsOnBattery,
|
|
ups10EstimatedMinutesRemaining,
|
|
ups10EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 2 }
|
|
|
|
ups10FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups10InputLineBads, ups10InputNumLines,
|
|
ups10InputFrequency, ups10InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 3 }
|
|
|
|
ups10FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups10OutputSource, ups10OutputFrequency,
|
|
ups10OutputNumLines, ups10OutputVoltage,
|
|
ups10OutputCurrent, ups10OutputPower,
|
|
ups10OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 4 }
|
|
|
|
ups10FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups10BypassFrequency, ups10BypassNumLines,
|
|
ups10BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 5 }
|
|
|
|
ups10FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups10AlarmsPresent, ups10AlarmDescr, ups10AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups10FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 6 }
|
|
|
|
ups10FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups10TestId, ups10TestSpinLock,
|
|
ups10TestResultsSummary, ups10TestResultsDetail,
|
|
ups10TestStartTime, ups10TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 7 }
|
|
|
|
ups10FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups10ShutdownType, ups10ShutdownAfterDelay,
|
|
ups10StartupAfterDelay, ups10RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups10FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups10FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 11 data
|
|
--
|
|
|
|
upsModule11 OBJECT IDENTIFIER ::= { upsModular 12 }
|
|
ups11Objects OBJECT IDENTIFIER ::= { upsModule11 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups11IdentName and
|
|
-- ups11IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups11Ident OBJECT IDENTIFIER ::= { ups11Objects 1 }
|
|
|
|
ups11IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups11Ident 1 }
|
|
|
|
ups11IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups11Ident 2 }
|
|
|
|
ups11IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups11IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups11Ident 3 }
|
|
|
|
ups11IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups11IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups11Ident 4 }
|
|
|
|
ups11IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups11Ident 5 }
|
|
|
|
ups11IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups11Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups11Battery OBJECT IDENTIFIER ::= { ups11Objects 2 }
|
|
|
|
ups11BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups11ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups11ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups11Battery 1 }
|
|
|
|
ups11SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups11Battery 2 }
|
|
|
|
ups11EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups11Battery 3 }
|
|
|
|
ups11EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups11Battery 4 }
|
|
|
|
ups11BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups11Battery 5 }
|
|
|
|
ups11BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups11Battery 6 }
|
|
|
|
ups11BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups11Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups11Input OBJECT IDENTIFIER ::= { ups11Objects 3 }
|
|
|
|
ups11InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups11Input 1 }
|
|
|
|
|
|
ups11InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups11Input 2 }
|
|
|
|
ups11InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups11InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups11InputNumLines."
|
|
::= { ups11Input 3 }
|
|
|
|
ups11InputEntry OBJECT-TYPE
|
|
SYNTAX Ups11InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups11InputLineIndex }
|
|
::= { ups11InputTable 1 }
|
|
|
|
Ups11InputEntry ::= SEQUENCE {
|
|
ups11InputLineIndex PositiveInteger,
|
|
ups11InputFrequency NonNegativeInteger,
|
|
ups11InputVoltage NonNegativeInteger,
|
|
ups11InputCurrent NonNegativeInteger,
|
|
ups11InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups11InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups11InputEntry 1 }
|
|
|
|
ups11InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups11InputEntry 2 }
|
|
|
|
ups11InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups11InputEntry 3 }
|
|
|
|
ups11InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups11InputEntry 4 }
|
|
|
|
ups11InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups11InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups11Output OBJECT IDENTIFIER ::= { ups11Objects 4 }
|
|
|
|
ups11OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups11Output 1 }
|
|
|
|
ups11OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups11Output 2 }
|
|
|
|
ups11OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups11Output 3 }
|
|
|
|
ups11OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups11OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups11OutputNumLines."
|
|
::= { ups11Output 4 }
|
|
|
|
ups11OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups11OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups11OutputLineIndex }
|
|
::= { ups11OutputTable 1 }
|
|
|
|
Ups11OutputEntry ::= SEQUENCE {
|
|
ups11OutputLineIndex PositiveInteger,
|
|
ups11OutputVoltage NonNegativeInteger,
|
|
ups11OutputCurrent NonNegativeInteger,
|
|
ups11OutputPower NonNegativeInteger,
|
|
ups11OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups11OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups11OutputEntry 1 }
|
|
|
|
ups11OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups11OutputEntry 2 }
|
|
|
|
ups11OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups11OutputEntry 3 }
|
|
|
|
ups11OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups11OutputEntry 4 }
|
|
|
|
ups11OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups11OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups11Bypass OBJECT IDENTIFIER ::= { ups11Objects 5 }
|
|
|
|
ups11BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups11Bypass 1 }
|
|
|
|
ups11BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups11Bypass 2 }
|
|
|
|
ups11BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups11BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups11BypassNumLines."
|
|
::= { ups11Bypass 3 }
|
|
|
|
ups11BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups11BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups11BypassLineIndex }
|
|
::= { ups11BypassTable 1 }
|
|
|
|
Ups11BypassEntry ::= SEQUENCE {
|
|
ups11BypassLineIndex PositiveInteger,
|
|
ups11BypassVoltage NonNegativeInteger,
|
|
ups11BypassCurrent NonNegativeInteger,
|
|
ups11BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups11BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups11BypassEntry 1 }
|
|
|
|
ups11BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups11BypassEntry 2 }
|
|
|
|
ups11BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups11BypassEntry 3 }
|
|
|
|
ups11BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups11BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups11Alarm OBJECT IDENTIFIER ::= { ups11Objects 6 }
|
|
|
|
ups11AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups11Alarm 1 }
|
|
|
|
ups11AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups11AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups11AlarmId equal to 1, and increments the value of
|
|
ups11AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups11AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups11AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups11AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups11AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups11AlarmsPresent."
|
|
::= { ups11Alarm 2 }
|
|
|
|
ups11AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups11AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups11AlarmId }
|
|
::= { ups11AlarmTable 1 }
|
|
|
|
Ups11AlarmEntry ::= SEQUENCE {
|
|
ups11AlarmId PositiveInteger,
|
|
ups11AlarmDescr AutonomousType,
|
|
ups11AlarmTime TimeStamp
|
|
}
|
|
|
|
ups11AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups11AlarmEntry 1 }
|
|
|
|
ups11AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups11AlarmEntry 2 }
|
|
|
|
ups11AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups11AlarmTime shall equal
|
|
0."
|
|
::= { ups11AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups11WellKnownAlarms OBJECT IDENTIFIER ::= { ups11Alarm 3 }
|
|
ups11AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups11WellKnownAlarms 1 }
|
|
|
|
ups11AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups11WellKnownAlarms 2 }
|
|
|
|
ups11AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups11ConfigLowBattTime."
|
|
::= { ups11WellKnownAlarms 3 }
|
|
|
|
|
|
ups11AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups11WellKnownAlarms 4 }
|
|
|
|
ups11AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups11WellKnownAlarms 5 }
|
|
|
|
ups11AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups11WellKnownAlarms 6 }
|
|
|
|
ups11AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups11WellKnownAlarms 7 }
|
|
|
|
ups11AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups11WellKnownAlarms 8 }
|
|
|
|
ups11AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups11WellKnownAlarms 9 }
|
|
|
|
ups11AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups11WellKnownAlarms 10 }
|
|
|
|
ups11AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups11WellKnownAlarms 11 }
|
|
|
|
ups11AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups11WellKnownAlarms 12 }
|
|
|
|
ups11AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups11WellKnownAlarms 13 }
|
|
|
|
ups11AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups11WellKnownAlarms 14 }
|
|
|
|
ups11AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups11WellKnownAlarms 15 }
|
|
|
|
ups11AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups11WellKnownAlarms 16 }
|
|
|
|
ups11AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups11WellKnownAlarms 17 }
|
|
|
|
ups11AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups11WellKnownAlarms 18 }
|
|
|
|
ups11AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups11WellKnownAlarms 19 }
|
|
|
|
ups11AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups11WellKnownAlarms 20 }
|
|
|
|
ups11AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups11WellKnownAlarms 21 }
|
|
|
|
ups11AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups11ShutdownAfterDelay countdown is underway."
|
|
::= { ups11WellKnownAlarms 22 }
|
|
|
|
ups11AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups11WellKnownAlarms 23 }
|
|
|
|
ups11AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups11WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups11Test OBJECT IDENTIFIER ::= { ups11Objects 7 }
|
|
|
|
ups11TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups11TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups11TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups11TestId variable to
|
|
ups11TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups11TestNoTestsInitiated is returned."
|
|
::= { ups11Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups11TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups11TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups11TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups11TestResultsSummary */
|
|
get (upsTestSpinLock, ups11TestResultsSummary,
|
|
ups11TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups11TestResultsSummary,
|
|
ups11TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups11TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups11TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups11Test 2 }
|
|
|
|
ups11TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups11TestId to ups11TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups11Test 3 }
|
|
|
|
ups11TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups11TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups11Test 4 }
|
|
|
|
ups11TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups11TestResultsSummary is noTestsInitiated(6),
|
|
ups11TestStartTime has the value 0."
|
|
::= { ups11Test 5 }
|
|
|
|
ups11TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups11TestResultsSummary is noTestsInitiated(6),
|
|
ups11TestElapsedTime has the value 0."
|
|
::= { ups11Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups11WellKnownTests OBJECT IDENTIFIER ::= { ups11Test 7 }
|
|
|
|
|
|
ups11TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups11WellKnownTests 1 }
|
|
|
|
ups11TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups11WellKnownTests 2 }
|
|
|
|
ups11TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups11WellKnownTests 3 }
|
|
|
|
ups11TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups11WellKnownTests 4 }
|
|
|
|
ups11TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups11WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups11Control OBJECT IDENTIFIER ::= { ups11Objects 8 }
|
|
|
|
ups11ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups11ShutdownAfterDelay and ups11RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups11Control 1 }
|
|
|
|
ups11ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups11ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups11ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups11ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups11ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups11ShutdownAfterDelay already in effect."
|
|
::= { ups11Control 2 }
|
|
|
|
ups11StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups11StartupAfterDelay
|
|
countdown or ups11RebootWithDuration countdown in
|
|
progress. When read, ups11StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups11Control 3 }
|
|
|
|
ups11RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups11ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups11RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups11Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups11Traps OBJECT IDENTIFIER ::= { upsModule11 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups11TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups11EstimatedMinutesRemaining, ups11SecondsOnBattery,
|
|
ups11ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups11Traps 1 }
|
|
|
|
ups11TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups11TestId, ups11TestSpinLock,
|
|
ups11TestResultsSummary, ups11TestResultsDetail,
|
|
ups11TestStartTime, ups11TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups11Traps 2 }
|
|
|
|
ups11TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups11AlarmId, ups11AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups11AlarmOnBattery and
|
|
ups11AlarmTestInProgress."
|
|
::= { ups11Traps 3 }
|
|
|
|
ups11TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups11AlarmId, ups11AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups11AlarmTestInProgress."
|
|
::= { ups11Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups11Conformance OBJECT IDENTIFIER ::= { upsModule11 3 }
|
|
|
|
ups11Compliances OBJECT IDENTIFIER ::= { ups11Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups11SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups11SubsetIdentGroup,
|
|
ups11SubsetBatteryGroup, ups11SubsetInputGroup,
|
|
ups11SubsetOutputGroup, ups11SubsetAlarmGroup,
|
|
ups11SubsetControlGroup }
|
|
|
|
OBJECT ups11BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups11AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups11AlarmOnBattery, ups11AlarmLowBattery,
|
|
ups11AlarmInputBad, ups11AlarmUpsOutputOff,
|
|
ups11AlarmUpsSystemOff, and ups11AlarmTestInProgress."
|
|
|
|
OBJECT ups11OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups11ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups11Compliances 1 }
|
|
|
|
ups11BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups11BasicIdentGroup,
|
|
ups11BasicBatteryGroup, ups11BasicInputGroup,
|
|
ups11BasicOutputGroup, ups11BasicAlarmGroup,
|
|
ups11BasicTestGroup, ups11BasicControlGroup }
|
|
|
|
|
|
OBJECT ups11AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups11AlarmOnBattery, ups11AlarmLowBattery,
|
|
ups11AlarmDepletedBattery, ups11AlarmTempBad,
|
|
ups11AlarmInputBad, ups11AlarmOutputOverload,
|
|
ups11AlarmOnBypass, ups11AlarmBypassBad,
|
|
ups11AlarmOutputOffAsRequested,
|
|
ups11AlarmUpsOffAsRequested, ups11AlarmUpsOutputOff,
|
|
ups11AlarmUpsSystemOff, ups11AlarmGeneralFault,
|
|
ups11AlarmDiagnosticTestFailed,
|
|
ups11AlarmCommunicationsLost, ups11AlarmShutdownPending,
|
|
and ups11AlarmTestInProgress."
|
|
|
|
OBJECT ups11TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups11TestNoTestsInitiated."
|
|
|
|
OBJECT ups11OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups11BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups11BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups11ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups11Compliances 2 }
|
|
|
|
ups11FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups11FullIdentGroup, ups11FullBatteryGroup,
|
|
ups11FullInputGroup, ups11FullOutputGroup,
|
|
ups11FullAlarmGroup, ups11FullTestGroup,
|
|
ups11FullControlGroup }
|
|
|
|
OBJECT ups11AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups11AlarmBatteryBad, ups11AlarmOnBattery,
|
|
ups11AlarmLowBattery, ups11AlarmDepletedBattery,
|
|
ups11AlarmTempBad, ups11AlarmInputBad, ups11AlarmOnBypass,
|
|
ups11AlarmBypassBad, ups11AlarmOutputOffAsRequested,
|
|
ups11AlarmUpsOffAsRequested, ups11AlarmUpsOutputOff,
|
|
ups11AlarmUpsSystemOff, ups11AlarmGeneralFault,
|
|
ups11AlarmDiagnosticTestFailed,
|
|
ups11AlarmCommunicationsLost, ups11AlarmShutdownPending,
|
|
and ups11AlarmTestInProgress."
|
|
|
|
OBJECT ups11TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups11TestNoTestsInitiated,
|
|
ups11TestGeneralSystemsTest, and
|
|
ups11TestQuickBatteryTest."
|
|
|
|
OBJECT ups11OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups11FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups11FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups11ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups11Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups11Groups OBJECT IDENTIFIER ::= { ups11Conformance 2 }
|
|
|
|
ups11SubsetGroups OBJECT IDENTIFIER ::= { ups11Groups 1 }
|
|
|
|
ups11SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups11IdentManufacturer, ups11IdentModel,
|
|
ups11IdentAgentSoftwareVersion, ups11IdentName,
|
|
ups11IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups11SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups11SubsetGroups 1 }
|
|
|
|
ups11SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups11BatteryStatus, ups11SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups11SubsetGroups 2 }
|
|
|
|
ups11SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups11InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups11SubsetGroups 3 }
|
|
|
|
ups11SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups11OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups11SubsetGroups 4 }
|
|
|
|
|
|
-- { ups11SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups11SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups11AlarmsPresent, ups11AlarmDescr, ups11AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups11SubsetGroups 6 }
|
|
|
|
-- { ups11SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups11SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups11ShutdownType, ups11ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups11SubsetGroups 8 }
|
|
|
|
ups11BasicGroups OBJECT IDENTIFIER ::= { ups11Groups 2 }
|
|
|
|
ups11BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups11IdentManufacturer, ups11IdentModel,
|
|
ups11IdentUPSSoftwareVersion,
|
|
ups11IdentAgentSoftwareVersion, ups11IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 1 }
|
|
|
|
ups11BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups11BatteryStatus, ups11SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 2 }
|
|
|
|
ups11BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups11InputLineBads, ups11InputNumLines,
|
|
ups11InputFrequency, ups11InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 3 }
|
|
|
|
ups11BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups11OutputSource, ups11OutputFrequency,
|
|
ups11OutputNumLines, ups11OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 4 }
|
|
|
|
ups11BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups11BypassFrequency, ups11BypassNumLines,
|
|
ups11BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 5 }
|
|
|
|
ups11BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups11AlarmsPresent, ups11AlarmDescr, ups11AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups11BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 6 }
|
|
|
|
ups11BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups11TestId, ups11TestSpinLock,
|
|
ups11TestResultsSummary, ups11TestResultsDetail,
|
|
ups11TestStartTime, ups11TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 7 }
|
|
|
|
ups11BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups11ShutdownType, ups11ShutdownAfterDelay,
|
|
ups11StartupAfterDelay, ups11RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups11BasicGroups 8 }
|
|
|
|
ups11FullGroups OBJECT IDENTIFIER ::= { ups11Groups 3 }
|
|
|
|
ups11FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups11IdentManufacturer, ups11IdentModel,
|
|
ups11IdentUPSSoftwareVersion,
|
|
ups11IdentAgentSoftwareVersion, ups11IdentName,
|
|
ups11IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups11FullGroups 1 }
|
|
|
|
ups11FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups11BatteryStatus, ups11SecondsOnBattery,
|
|
ups11EstimatedMinutesRemaining,
|
|
ups11EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 2 }
|
|
|
|
ups11FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups11InputLineBads, ups11InputNumLines,
|
|
ups11InputFrequency, ups11InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 3 }
|
|
|
|
ups11FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups11OutputSource, ups11OutputFrequency,
|
|
ups11OutputNumLines, ups11OutputVoltage,
|
|
ups11OutputCurrent, ups11OutputPower,
|
|
ups11OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 4 }
|
|
|
|
ups11FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups11BypassFrequency, ups11BypassNumLines,
|
|
ups11BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 5 }
|
|
|
|
ups11FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups11AlarmsPresent, ups11AlarmDescr, ups11AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups11FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 6 }
|
|
|
|
ups11FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups11TestId, ups11TestSpinLock,
|
|
ups11TestResultsSummary, ups11TestResultsDetail,
|
|
ups11TestStartTime, ups11TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 7 }
|
|
|
|
ups11FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups11ShutdownType, ups11ShutdownAfterDelay,
|
|
ups11StartupAfterDelay, ups11RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups11FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups11FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 12 data
|
|
--
|
|
|
|
upsModule12 OBJECT IDENTIFIER ::= { upsModular 13 }
|
|
ups12Objects OBJECT IDENTIFIER ::= { upsModule12 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups12IdentName and
|
|
-- ups12IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups12Ident OBJECT IDENTIFIER ::= { ups12Objects 1 }
|
|
|
|
ups12IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups12Ident 1 }
|
|
|
|
ups12IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups12Ident 2 }
|
|
|
|
ups12IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups12IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups12Ident 3 }
|
|
|
|
ups12IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups12IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups12Ident 4 }
|
|
|
|
ups12IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups12Ident 5 }
|
|
|
|
ups12IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups12Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups12Battery OBJECT IDENTIFIER ::= { ups12Objects 2 }
|
|
|
|
ups12BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups12ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups12ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups12Battery 1 }
|
|
|
|
ups12SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups12Battery 2 }
|
|
|
|
ups12EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups12Battery 3 }
|
|
|
|
ups12EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups12Battery 4 }
|
|
|
|
ups12BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups12Battery 5 }
|
|
|
|
ups12BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups12Battery 6 }
|
|
|
|
ups12BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups12Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups12Input OBJECT IDENTIFIER ::= { ups12Objects 3 }
|
|
|
|
ups12InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups12Input 1 }
|
|
|
|
|
|
ups12InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups12Input 2 }
|
|
|
|
ups12InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups12InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups12InputNumLines."
|
|
::= { ups12Input 3 }
|
|
|
|
ups12InputEntry OBJECT-TYPE
|
|
SYNTAX Ups12InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups12InputLineIndex }
|
|
::= { ups12InputTable 1 }
|
|
|
|
Ups12InputEntry ::= SEQUENCE {
|
|
ups12InputLineIndex PositiveInteger,
|
|
ups12InputFrequency NonNegativeInteger,
|
|
ups12InputVoltage NonNegativeInteger,
|
|
ups12InputCurrent NonNegativeInteger,
|
|
ups12InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups12InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups12InputEntry 1 }
|
|
|
|
ups12InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups12InputEntry 2 }
|
|
|
|
ups12InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups12InputEntry 3 }
|
|
|
|
ups12InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups12InputEntry 4 }
|
|
|
|
ups12InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups12InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups12Output OBJECT IDENTIFIER ::= { ups12Objects 4 }
|
|
|
|
ups12OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups12Output 1 }
|
|
|
|
ups12OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups12Output 2 }
|
|
|
|
ups12OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups12Output 3 }
|
|
|
|
ups12OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups12OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups12OutputNumLines."
|
|
::= { ups12Output 4 }
|
|
|
|
ups12OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups12OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups12OutputLineIndex }
|
|
::= { ups12OutputTable 1 }
|
|
|
|
Ups12OutputEntry ::= SEQUENCE {
|
|
ups12OutputLineIndex PositiveInteger,
|
|
ups12OutputVoltage NonNegativeInteger,
|
|
ups12OutputCurrent NonNegativeInteger,
|
|
ups12OutputPower NonNegativeInteger,
|
|
ups12OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups12OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups12OutputEntry 1 }
|
|
|
|
ups12OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups12OutputEntry 2 }
|
|
|
|
ups12OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups12OutputEntry 3 }
|
|
|
|
ups12OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups12OutputEntry 4 }
|
|
|
|
ups12OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups12OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups12Bypass OBJECT IDENTIFIER ::= { ups12Objects 5 }
|
|
|
|
ups12BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups12Bypass 1 }
|
|
|
|
ups12BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups12Bypass 2 }
|
|
|
|
ups12BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups12BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups12BypassNumLines."
|
|
::= { ups12Bypass 3 }
|
|
|
|
ups12BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups12BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups12BypassLineIndex }
|
|
::= { ups12BypassTable 1 }
|
|
|
|
Ups12BypassEntry ::= SEQUENCE {
|
|
ups12BypassLineIndex PositiveInteger,
|
|
ups12BypassVoltage NonNegativeInteger,
|
|
ups12BypassCurrent NonNegativeInteger,
|
|
ups12BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups12BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups12BypassEntry 1 }
|
|
|
|
ups12BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups12BypassEntry 2 }
|
|
|
|
ups12BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups12BypassEntry 3 }
|
|
|
|
ups12BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups12BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups12Alarm OBJECT IDENTIFIER ::= { ups12Objects 6 }
|
|
|
|
ups12AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups12Alarm 1 }
|
|
|
|
ups12AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups12AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups12AlarmId equal to 1, and increments the value of
|
|
ups12AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups12AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups12AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups12AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups12AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups12AlarmsPresent."
|
|
::= { ups12Alarm 2 }
|
|
|
|
ups12AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups12AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups12AlarmId }
|
|
::= { ups12AlarmTable 1 }
|
|
|
|
Ups12AlarmEntry ::= SEQUENCE {
|
|
ups12AlarmId PositiveInteger,
|
|
ups12AlarmDescr AutonomousType,
|
|
ups12AlarmTime TimeStamp
|
|
}
|
|
|
|
ups12AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups12AlarmEntry 1 }
|
|
|
|
ups12AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups12AlarmEntry 2 }
|
|
|
|
ups12AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups12AlarmTime shall equal
|
|
0."
|
|
::= { ups12AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups12WellKnownAlarms OBJECT IDENTIFIER ::= { ups12Alarm 3 }
|
|
ups12AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups12WellKnownAlarms 1 }
|
|
|
|
ups12AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups12WellKnownAlarms 2 }
|
|
|
|
ups12AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups12ConfigLowBattTime."
|
|
::= { ups12WellKnownAlarms 3 }
|
|
|
|
|
|
ups12AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups12WellKnownAlarms 4 }
|
|
|
|
ups12AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups12WellKnownAlarms 5 }
|
|
|
|
ups12AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups12WellKnownAlarms 6 }
|
|
|
|
ups12AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups12WellKnownAlarms 7 }
|
|
|
|
ups12AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups12WellKnownAlarms 8 }
|
|
|
|
ups12AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups12WellKnownAlarms 9 }
|
|
|
|
ups12AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups12WellKnownAlarms 10 }
|
|
|
|
ups12AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups12WellKnownAlarms 11 }
|
|
|
|
ups12AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups12WellKnownAlarms 12 }
|
|
|
|
ups12AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups12WellKnownAlarms 13 }
|
|
|
|
ups12AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups12WellKnownAlarms 14 }
|
|
|
|
ups12AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups12WellKnownAlarms 15 }
|
|
|
|
ups12AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups12WellKnownAlarms 16 }
|
|
|
|
ups12AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups12WellKnownAlarms 17 }
|
|
|
|
ups12AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups12WellKnownAlarms 18 }
|
|
|
|
ups12AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups12WellKnownAlarms 19 }
|
|
|
|
ups12AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups12WellKnownAlarms 20 }
|
|
|
|
ups12AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups12WellKnownAlarms 21 }
|
|
|
|
ups12AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups12ShutdownAfterDelay countdown is underway."
|
|
::= { ups12WellKnownAlarms 22 }
|
|
|
|
ups12AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups12WellKnownAlarms 23 }
|
|
|
|
ups12AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups12WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups12Test OBJECT IDENTIFIER ::= { ups12Objects 7 }
|
|
|
|
ups12TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups12TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups12TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups12TestId variable to
|
|
ups12TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups12TestNoTestsInitiated is returned."
|
|
::= { ups12Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups12TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups12TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups12TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups12TestResultsSummary */
|
|
get (upsTestSpinLock, ups12TestResultsSummary,
|
|
ups12TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups12TestResultsSummary,
|
|
ups12TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups12TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups12TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups12Test 2 }
|
|
|
|
ups12TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups12TestId to ups12TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups12Test 3 }
|
|
|
|
ups12TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups12TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups12Test 4 }
|
|
|
|
ups12TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups12TestResultsSummary is noTestsInitiated(6),
|
|
ups12TestStartTime has the value 0."
|
|
::= { ups12Test 5 }
|
|
|
|
ups12TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups12TestResultsSummary is noTestsInitiated(6),
|
|
ups12TestElapsedTime has the value 0."
|
|
::= { ups12Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups12WellKnownTests OBJECT IDENTIFIER ::= { ups12Test 7 }
|
|
|
|
|
|
ups12TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups12WellKnownTests 1 }
|
|
|
|
ups12TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups12WellKnownTests 2 }
|
|
|
|
ups12TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups12WellKnownTests 3 }
|
|
|
|
ups12TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups12WellKnownTests 4 }
|
|
|
|
ups12TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups12WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups12Control OBJECT IDENTIFIER ::= { ups12Objects 8 }
|
|
|
|
ups12ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups12ShutdownAfterDelay and ups12RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups12Control 1 }
|
|
|
|
ups12ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups12ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups12ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups12ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups12ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups12ShutdownAfterDelay already in effect."
|
|
::= { ups12Control 2 }
|
|
|
|
ups12StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups12StartupAfterDelay
|
|
countdown or ups12RebootWithDuration countdown in
|
|
progress. When read, ups12StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups12Control 3 }
|
|
|
|
ups12RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups12ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups12RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups12Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups12Traps OBJECT IDENTIFIER ::= { upsModule12 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups12TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups12EstimatedMinutesRemaining, ups12SecondsOnBattery,
|
|
ups12ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups12Traps 1 }
|
|
|
|
ups12TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups12TestId, ups12TestSpinLock,
|
|
ups12TestResultsSummary, ups12TestResultsDetail,
|
|
ups12TestStartTime, ups12TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups12Traps 2 }
|
|
|
|
ups12TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups12AlarmId, ups12AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups12AlarmOnBattery and
|
|
ups12AlarmTestInProgress."
|
|
::= { ups12Traps 3 }
|
|
|
|
ups12TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups12AlarmId, ups12AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups12AlarmTestInProgress."
|
|
::= { ups12Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups12Conformance OBJECT IDENTIFIER ::= { upsModule12 3 }
|
|
|
|
ups12Compliances OBJECT IDENTIFIER ::= { ups12Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups12SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups12SubsetIdentGroup,
|
|
ups12SubsetBatteryGroup, ups12SubsetInputGroup,
|
|
ups12SubsetOutputGroup, ups12SubsetAlarmGroup,
|
|
ups12SubsetControlGroup }
|
|
|
|
OBJECT ups12BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups12AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups12AlarmOnBattery, ups12AlarmLowBattery,
|
|
ups12AlarmInputBad, ups12AlarmUpsOutputOff,
|
|
ups12AlarmUpsSystemOff, and ups12AlarmTestInProgress."
|
|
|
|
OBJECT ups12OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups12ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups12Compliances 1 }
|
|
|
|
ups12BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups12BasicIdentGroup,
|
|
ups12BasicBatteryGroup, ups12BasicInputGroup,
|
|
ups12BasicOutputGroup, ups12BasicAlarmGroup,
|
|
ups12BasicTestGroup, ups12BasicControlGroup }
|
|
|
|
|
|
OBJECT ups12AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups12AlarmOnBattery, ups12AlarmLowBattery,
|
|
ups12AlarmDepletedBattery, ups12AlarmTempBad,
|
|
ups12AlarmInputBad, ups12AlarmOutputOverload,
|
|
ups12AlarmOnBypass, ups12AlarmBypassBad,
|
|
ups12AlarmOutputOffAsRequested,
|
|
ups12AlarmUpsOffAsRequested, ups12AlarmUpsOutputOff,
|
|
ups12AlarmUpsSystemOff, ups12AlarmGeneralFault,
|
|
ups12AlarmDiagnosticTestFailed,
|
|
ups12AlarmCommunicationsLost, ups12AlarmShutdownPending,
|
|
and ups12AlarmTestInProgress."
|
|
|
|
OBJECT ups12TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups12TestNoTestsInitiated."
|
|
|
|
OBJECT ups12OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups12BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups12BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups12ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups12Compliances 2 }
|
|
|
|
ups12FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups12FullIdentGroup, ups12FullBatteryGroup,
|
|
ups12FullInputGroup, ups12FullOutputGroup,
|
|
ups12FullAlarmGroup, ups12FullTestGroup,
|
|
ups12FullControlGroup }
|
|
|
|
OBJECT ups12AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups12AlarmBatteryBad, ups12AlarmOnBattery,
|
|
ups12AlarmLowBattery, ups12AlarmDepletedBattery,
|
|
ups12AlarmTempBad, ups12AlarmInputBad, ups12AlarmOnBypass,
|
|
ups12AlarmBypassBad, ups12AlarmOutputOffAsRequested,
|
|
ups12AlarmUpsOffAsRequested, ups12AlarmUpsOutputOff,
|
|
ups12AlarmUpsSystemOff, ups12AlarmGeneralFault,
|
|
ups12AlarmDiagnosticTestFailed,
|
|
ups12AlarmCommunicationsLost, ups12AlarmShutdownPending,
|
|
and ups12AlarmTestInProgress."
|
|
|
|
OBJECT ups12TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups12TestNoTestsInitiated,
|
|
ups12TestGeneralSystemsTest, and
|
|
ups12TestQuickBatteryTest."
|
|
|
|
OBJECT ups12OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups12FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups12FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups12ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups12Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups12Groups OBJECT IDENTIFIER ::= { ups12Conformance 2 }
|
|
|
|
ups12SubsetGroups OBJECT IDENTIFIER ::= { ups12Groups 1 }
|
|
|
|
ups12SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups12IdentManufacturer, ups12IdentModel,
|
|
ups12IdentAgentSoftwareVersion, ups12IdentName,
|
|
ups12IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups12SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups12SubsetGroups 1 }
|
|
|
|
ups12SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups12BatteryStatus, ups12SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups12SubsetGroups 2 }
|
|
|
|
ups12SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups12InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups12SubsetGroups 3 }
|
|
|
|
ups12SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups12OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups12SubsetGroups 4 }
|
|
|
|
|
|
-- { ups12SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups12SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups12AlarmsPresent, ups12AlarmDescr, ups12AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups12SubsetGroups 6 }
|
|
|
|
-- { ups12SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups12SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups12ShutdownType, ups12ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups12SubsetGroups 8 }
|
|
|
|
ups12BasicGroups OBJECT IDENTIFIER ::= { ups12Groups 2 }
|
|
|
|
ups12BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups12IdentManufacturer, ups12IdentModel,
|
|
ups12IdentUPSSoftwareVersion,
|
|
ups12IdentAgentSoftwareVersion, ups12IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 1 }
|
|
|
|
ups12BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups12BatteryStatus, ups12SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 2 }
|
|
|
|
ups12BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups12InputLineBads, ups12InputNumLines,
|
|
ups12InputFrequency, ups12InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 3 }
|
|
|
|
ups12BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups12OutputSource, ups12OutputFrequency,
|
|
ups12OutputNumLines, ups12OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 4 }
|
|
|
|
ups12BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups12BypassFrequency, ups12BypassNumLines,
|
|
ups12BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 5 }
|
|
|
|
ups12BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups12AlarmsPresent, ups12AlarmDescr, ups12AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups12BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 6 }
|
|
|
|
ups12BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups12TestId, ups12TestSpinLock,
|
|
ups12TestResultsSummary, ups12TestResultsDetail,
|
|
ups12TestStartTime, ups12TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 7 }
|
|
|
|
ups12BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups12ShutdownType, ups12ShutdownAfterDelay,
|
|
ups12StartupAfterDelay, ups12RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups12BasicGroups 8 }
|
|
|
|
ups12FullGroups OBJECT IDENTIFIER ::= { ups12Groups 3 }
|
|
|
|
ups12FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups12IdentManufacturer, ups12IdentModel,
|
|
ups12IdentUPSSoftwareVersion,
|
|
ups12IdentAgentSoftwareVersion, ups12IdentName,
|
|
ups12IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups12FullGroups 1 }
|
|
|
|
ups12FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups12BatteryStatus, ups12SecondsOnBattery,
|
|
ups12EstimatedMinutesRemaining,
|
|
ups12EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 2 }
|
|
|
|
ups12FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups12InputLineBads, ups12InputNumLines,
|
|
ups12InputFrequency, ups12InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 3 }
|
|
|
|
ups12FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups12OutputSource, ups12OutputFrequency,
|
|
ups12OutputNumLines, ups12OutputVoltage,
|
|
ups12OutputCurrent, ups12OutputPower,
|
|
ups12OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 4 }
|
|
|
|
ups12FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups12BypassFrequency, ups12BypassNumLines,
|
|
ups12BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 5 }
|
|
|
|
ups12FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups12AlarmsPresent, ups12AlarmDescr, ups12AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups12FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 6 }
|
|
|
|
ups12FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups12TestId, ups12TestSpinLock,
|
|
ups12TestResultsSummary, ups12TestResultsDetail,
|
|
ups12TestStartTime, ups12TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 7 }
|
|
|
|
ups12FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups12ShutdownType, ups12ShutdownAfterDelay,
|
|
ups12StartupAfterDelay, ups12RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups12FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups12FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 13 data
|
|
--
|
|
|
|
upsModule13 OBJECT IDENTIFIER ::= { upsModular 14 }
|
|
ups13Objects OBJECT IDENTIFIER ::= { upsModule13 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups13IdentName and
|
|
-- ups13IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups13Ident OBJECT IDENTIFIER ::= { ups13Objects 1 }
|
|
|
|
ups13IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups13Ident 1 }
|
|
|
|
ups13IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups13Ident 2 }
|
|
|
|
ups13IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups13IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups13Ident 3 }
|
|
|
|
ups13IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups13IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups13Ident 4 }
|
|
|
|
ups13IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups13Ident 5 }
|
|
|
|
ups13IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups13Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups13Battery OBJECT IDENTIFIER ::= { ups13Objects 2 }
|
|
|
|
ups13BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups13ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups13ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups13Battery 1 }
|
|
|
|
ups13SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups13Battery 2 }
|
|
|
|
ups13EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups13Battery 3 }
|
|
|
|
ups13EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups13Battery 4 }
|
|
|
|
ups13BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups13Battery 5 }
|
|
|
|
ups13BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups13Battery 6 }
|
|
|
|
ups13BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups13Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups13Input OBJECT IDENTIFIER ::= { ups13Objects 3 }
|
|
|
|
ups13InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups13Input 1 }
|
|
|
|
|
|
ups13InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups13Input 2 }
|
|
|
|
ups13InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups13InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups13InputNumLines."
|
|
::= { ups13Input 3 }
|
|
|
|
ups13InputEntry OBJECT-TYPE
|
|
SYNTAX Ups13InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups13InputLineIndex }
|
|
::= { ups13InputTable 1 }
|
|
|
|
Ups13InputEntry ::= SEQUENCE {
|
|
ups13InputLineIndex PositiveInteger,
|
|
ups13InputFrequency NonNegativeInteger,
|
|
ups13InputVoltage NonNegativeInteger,
|
|
ups13InputCurrent NonNegativeInteger,
|
|
ups13InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups13InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups13InputEntry 1 }
|
|
|
|
ups13InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups13InputEntry 2 }
|
|
|
|
ups13InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups13InputEntry 3 }
|
|
|
|
ups13InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups13InputEntry 4 }
|
|
|
|
ups13InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups13InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups13Output OBJECT IDENTIFIER ::= { ups13Objects 4 }
|
|
|
|
ups13OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups13Output 1 }
|
|
|
|
ups13OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups13Output 2 }
|
|
|
|
ups13OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups13Output 3 }
|
|
|
|
ups13OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups13OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups13OutputNumLines."
|
|
::= { ups13Output 4 }
|
|
|
|
ups13OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups13OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups13OutputLineIndex }
|
|
::= { ups13OutputTable 1 }
|
|
|
|
Ups13OutputEntry ::= SEQUENCE {
|
|
ups13OutputLineIndex PositiveInteger,
|
|
ups13OutputVoltage NonNegativeInteger,
|
|
ups13OutputCurrent NonNegativeInteger,
|
|
ups13OutputPower NonNegativeInteger,
|
|
ups13OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups13OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups13OutputEntry 1 }
|
|
|
|
ups13OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups13OutputEntry 2 }
|
|
|
|
ups13OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups13OutputEntry 3 }
|
|
|
|
ups13OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups13OutputEntry 4 }
|
|
|
|
ups13OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups13OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups13Bypass OBJECT IDENTIFIER ::= { ups13Objects 5 }
|
|
|
|
ups13BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups13Bypass 1 }
|
|
|
|
ups13BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups13Bypass 2 }
|
|
|
|
ups13BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups13BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups13BypassNumLines."
|
|
::= { ups13Bypass 3 }
|
|
|
|
ups13BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups13BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups13BypassLineIndex }
|
|
::= { ups13BypassTable 1 }
|
|
|
|
Ups13BypassEntry ::= SEQUENCE {
|
|
ups13BypassLineIndex PositiveInteger,
|
|
ups13BypassVoltage NonNegativeInteger,
|
|
ups13BypassCurrent NonNegativeInteger,
|
|
ups13BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups13BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups13BypassEntry 1 }
|
|
|
|
ups13BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups13BypassEntry 2 }
|
|
|
|
ups13BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups13BypassEntry 3 }
|
|
|
|
ups13BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups13BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups13Alarm OBJECT IDENTIFIER ::= { ups13Objects 6 }
|
|
|
|
ups13AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups13Alarm 1 }
|
|
|
|
ups13AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups13AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups13AlarmId equal to 1, and increments the value of
|
|
ups13AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups13AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups13AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups13AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups13AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups13AlarmsPresent."
|
|
::= { ups13Alarm 2 }
|
|
|
|
ups13AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups13AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups13AlarmId }
|
|
::= { ups13AlarmTable 1 }
|
|
|
|
Ups13AlarmEntry ::= SEQUENCE {
|
|
ups13AlarmId PositiveInteger,
|
|
ups13AlarmDescr AutonomousType,
|
|
ups13AlarmTime TimeStamp
|
|
}
|
|
|
|
ups13AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups13AlarmEntry 1 }
|
|
|
|
ups13AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups13AlarmEntry 2 }
|
|
|
|
ups13AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups13AlarmTime shall equal
|
|
0."
|
|
::= { ups13AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups13WellKnownAlarms OBJECT IDENTIFIER ::= { ups13Alarm 3 }
|
|
ups13AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups13WellKnownAlarms 1 }
|
|
|
|
ups13AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups13WellKnownAlarms 2 }
|
|
|
|
ups13AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups13ConfigLowBattTime."
|
|
::= { ups13WellKnownAlarms 3 }
|
|
|
|
|
|
ups13AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups13WellKnownAlarms 4 }
|
|
|
|
ups13AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups13WellKnownAlarms 5 }
|
|
|
|
ups13AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups13WellKnownAlarms 6 }
|
|
|
|
ups13AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups13WellKnownAlarms 7 }
|
|
|
|
ups13AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups13WellKnownAlarms 8 }
|
|
|
|
ups13AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups13WellKnownAlarms 9 }
|
|
|
|
ups13AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups13WellKnownAlarms 10 }
|
|
|
|
ups13AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups13WellKnownAlarms 11 }
|
|
|
|
ups13AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups13WellKnownAlarms 12 }
|
|
|
|
ups13AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups13WellKnownAlarms 13 }
|
|
|
|
ups13AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups13WellKnownAlarms 14 }
|
|
|
|
ups13AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups13WellKnownAlarms 15 }
|
|
|
|
ups13AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups13WellKnownAlarms 16 }
|
|
|
|
ups13AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups13WellKnownAlarms 17 }
|
|
|
|
ups13AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups13WellKnownAlarms 18 }
|
|
|
|
ups13AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups13WellKnownAlarms 19 }
|
|
|
|
ups13AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups13WellKnownAlarms 20 }
|
|
|
|
ups13AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups13WellKnownAlarms 21 }
|
|
|
|
ups13AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups13ShutdownAfterDelay countdown is underway."
|
|
::= { ups13WellKnownAlarms 22 }
|
|
|
|
ups13AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups13WellKnownAlarms 23 }
|
|
|
|
ups13AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups13WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups13Test OBJECT IDENTIFIER ::= { ups13Objects 7 }
|
|
|
|
ups13TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups13TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups13TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups13TestId variable to
|
|
ups13TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups13TestNoTestsInitiated is returned."
|
|
::= { ups13Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups13TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups13TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups13TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups13TestResultsSummary */
|
|
get (upsTestSpinLock, ups13TestResultsSummary,
|
|
ups13TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups13TestResultsSummary,
|
|
ups13TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups13TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups13TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups13Test 2 }
|
|
|
|
ups13TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups13TestId to ups13TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups13Test 3 }
|
|
|
|
ups13TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups13TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups13Test 4 }
|
|
|
|
ups13TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups13TestResultsSummary is noTestsInitiated(6),
|
|
ups13TestStartTime has the value 0."
|
|
::= { ups13Test 5 }
|
|
|
|
ups13TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups13TestResultsSummary is noTestsInitiated(6),
|
|
ups13TestElapsedTime has the value 0."
|
|
::= { ups13Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups13WellKnownTests OBJECT IDENTIFIER ::= { ups13Test 7 }
|
|
|
|
|
|
ups13TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups13WellKnownTests 1 }
|
|
|
|
ups13TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups13WellKnownTests 2 }
|
|
|
|
ups13TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups13WellKnownTests 3 }
|
|
|
|
ups13TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups13WellKnownTests 4 }
|
|
|
|
ups13TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups13WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups13Control OBJECT IDENTIFIER ::= { ups13Objects 8 }
|
|
|
|
ups13ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups13ShutdownAfterDelay and ups13RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups13Control 1 }
|
|
|
|
ups13ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups13ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups13ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups13ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups13ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups13ShutdownAfterDelay already in effect."
|
|
::= { ups13Control 2 }
|
|
|
|
ups13StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups13StartupAfterDelay
|
|
countdown or ups13RebootWithDuration countdown in
|
|
progress. When read, ups13StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups13Control 3 }
|
|
|
|
ups13RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups13ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups13RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups13Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups13Traps OBJECT IDENTIFIER ::= { upsModule13 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups13TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups13EstimatedMinutesRemaining, ups13SecondsOnBattery,
|
|
ups13ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups13Traps 1 }
|
|
|
|
ups13TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups13TestId, ups13TestSpinLock,
|
|
ups13TestResultsSummary, ups13TestResultsDetail,
|
|
ups13TestStartTime, ups13TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups13Traps 2 }
|
|
|
|
ups13TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups13AlarmId, ups13AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups13AlarmOnBattery and
|
|
ups13AlarmTestInProgress."
|
|
::= { ups13Traps 3 }
|
|
|
|
ups13TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups13AlarmId, ups13AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups13AlarmTestInProgress."
|
|
::= { ups13Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups13Conformance OBJECT IDENTIFIER ::= { upsModule13 3 }
|
|
|
|
ups13Compliances OBJECT IDENTIFIER ::= { ups13Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups13SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups13SubsetIdentGroup,
|
|
ups13SubsetBatteryGroup, ups13SubsetInputGroup,
|
|
ups13SubsetOutputGroup, ups13SubsetAlarmGroup,
|
|
ups13SubsetControlGroup }
|
|
|
|
OBJECT ups13BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups13AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups13AlarmOnBattery, ups13AlarmLowBattery,
|
|
ups13AlarmInputBad, ups13AlarmUpsOutputOff,
|
|
ups13AlarmUpsSystemOff, and ups13AlarmTestInProgress."
|
|
|
|
OBJECT ups13OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups13ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups13Compliances 1 }
|
|
|
|
ups13BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups13BasicIdentGroup,
|
|
ups13BasicBatteryGroup, ups13BasicInputGroup,
|
|
ups13BasicOutputGroup, ups13BasicAlarmGroup,
|
|
ups13BasicTestGroup, ups13BasicControlGroup }
|
|
|
|
|
|
OBJECT ups13AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups13AlarmOnBattery, ups13AlarmLowBattery,
|
|
ups13AlarmDepletedBattery, ups13AlarmTempBad,
|
|
ups13AlarmInputBad, ups13AlarmOutputOverload,
|
|
ups13AlarmOnBypass, ups13AlarmBypassBad,
|
|
ups13AlarmOutputOffAsRequested,
|
|
ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff,
|
|
ups13AlarmUpsSystemOff, ups13AlarmGeneralFault,
|
|
ups13AlarmDiagnosticTestFailed,
|
|
ups13AlarmCommunicationsLost, ups13AlarmShutdownPending,
|
|
and ups13AlarmTestInProgress."
|
|
|
|
OBJECT ups13TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups13TestNoTestsInitiated."
|
|
|
|
OBJECT ups13OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups13BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups13BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups13ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups13Compliances 2 }
|
|
|
|
ups13FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups13FullIdentGroup, ups13FullBatteryGroup,
|
|
ups13FullInputGroup, ups13FullOutputGroup,
|
|
ups13FullAlarmGroup, ups13FullTestGroup,
|
|
ups13FullControlGroup }
|
|
|
|
OBJECT ups13AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups13AlarmBatteryBad, ups13AlarmOnBattery,
|
|
ups13AlarmLowBattery, ups13AlarmDepletedBattery,
|
|
ups13AlarmTempBad, ups13AlarmInputBad, ups13AlarmOnBypass,
|
|
ups13AlarmBypassBad, ups13AlarmOutputOffAsRequested,
|
|
ups13AlarmUpsOffAsRequested, ups13AlarmUpsOutputOff,
|
|
ups13AlarmUpsSystemOff, ups13AlarmGeneralFault,
|
|
ups13AlarmDiagnosticTestFailed,
|
|
ups13AlarmCommunicationsLost, ups13AlarmShutdownPending,
|
|
and ups13AlarmTestInProgress."
|
|
|
|
OBJECT ups13TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups13TestNoTestsInitiated,
|
|
ups13TestGeneralSystemsTest, and
|
|
ups13TestQuickBatteryTest."
|
|
|
|
OBJECT ups13OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups13FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups13FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups13ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups13Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups13Groups OBJECT IDENTIFIER ::= { ups13Conformance 2 }
|
|
|
|
ups13SubsetGroups OBJECT IDENTIFIER ::= { ups13Groups 1 }
|
|
|
|
ups13SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups13IdentManufacturer, ups13IdentModel,
|
|
ups13IdentAgentSoftwareVersion, ups13IdentName,
|
|
ups13IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups13SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups13SubsetGroups 1 }
|
|
|
|
ups13SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups13BatteryStatus, ups13SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups13SubsetGroups 2 }
|
|
|
|
ups13SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups13InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups13SubsetGroups 3 }
|
|
|
|
ups13SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups13OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups13SubsetGroups 4 }
|
|
|
|
|
|
-- { ups13SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups13SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups13AlarmsPresent, ups13AlarmDescr, ups13AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups13SubsetGroups 6 }
|
|
|
|
-- { ups13SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups13SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups13ShutdownType, ups13ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups13SubsetGroups 8 }
|
|
|
|
ups13BasicGroups OBJECT IDENTIFIER ::= { ups13Groups 2 }
|
|
|
|
ups13BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups13IdentManufacturer, ups13IdentModel,
|
|
ups13IdentUPSSoftwareVersion,
|
|
ups13IdentAgentSoftwareVersion, ups13IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 1 }
|
|
|
|
ups13BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups13BatteryStatus, ups13SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 2 }
|
|
|
|
ups13BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups13InputLineBads, ups13InputNumLines,
|
|
ups13InputFrequency, ups13InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 3 }
|
|
|
|
ups13BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups13OutputSource, ups13OutputFrequency,
|
|
ups13OutputNumLines, ups13OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 4 }
|
|
|
|
ups13BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups13BypassFrequency, ups13BypassNumLines,
|
|
ups13BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 5 }
|
|
|
|
ups13BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups13AlarmsPresent, ups13AlarmDescr, ups13AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups13BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 6 }
|
|
|
|
ups13BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups13TestId, ups13TestSpinLock,
|
|
ups13TestResultsSummary, ups13TestResultsDetail,
|
|
ups13TestStartTime, ups13TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 7 }
|
|
|
|
ups13BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups13ShutdownType, ups13ShutdownAfterDelay,
|
|
ups13StartupAfterDelay, ups13RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups13BasicGroups 8 }
|
|
|
|
ups13FullGroups OBJECT IDENTIFIER ::= { ups13Groups 3 }
|
|
|
|
ups13FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups13IdentManufacturer, ups13IdentModel,
|
|
ups13IdentUPSSoftwareVersion,
|
|
ups13IdentAgentSoftwareVersion, ups13IdentName,
|
|
ups13IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups13FullGroups 1 }
|
|
|
|
ups13FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups13BatteryStatus, ups13SecondsOnBattery,
|
|
ups13EstimatedMinutesRemaining,
|
|
ups13EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 2 }
|
|
|
|
ups13FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups13InputLineBads, ups13InputNumLines,
|
|
ups13InputFrequency, ups13InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 3 }
|
|
|
|
ups13FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups13OutputSource, ups13OutputFrequency,
|
|
ups13OutputNumLines, ups13OutputVoltage,
|
|
ups13OutputCurrent, ups13OutputPower,
|
|
ups13OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 4 }
|
|
|
|
ups13FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups13BypassFrequency, ups13BypassNumLines,
|
|
ups13BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 5 }
|
|
|
|
ups13FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups13AlarmsPresent, ups13AlarmDescr, ups13AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups13FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 6 }
|
|
|
|
ups13FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups13TestId, ups13TestSpinLock,
|
|
ups13TestResultsSummary, ups13TestResultsDetail,
|
|
ups13TestStartTime, ups13TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 7 }
|
|
|
|
ups13FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups13ShutdownType, ups13ShutdownAfterDelay,
|
|
ups13StartupAfterDelay, ups13RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups13FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups13FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 14 data
|
|
--
|
|
|
|
upsModule14 OBJECT IDENTIFIER ::= { upsModular 15 }
|
|
ups14Objects OBJECT IDENTIFIER ::= { upsModule14 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups14IdentName and
|
|
-- ups14IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups14Ident OBJECT IDENTIFIER ::= { ups14Objects 1 }
|
|
|
|
ups14IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups14Ident 1 }
|
|
|
|
ups14IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups14Ident 2 }
|
|
|
|
ups14IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups14IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups14Ident 3 }
|
|
|
|
ups14IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups14IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups14Ident 4 }
|
|
|
|
ups14IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups14Ident 5 }
|
|
|
|
ups14IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups14Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups14Battery OBJECT IDENTIFIER ::= { ups14Objects 2 }
|
|
|
|
ups14BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups14ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups14ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups14Battery 1 }
|
|
|
|
ups14SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups14Battery 2 }
|
|
|
|
ups14EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups14Battery 3 }
|
|
|
|
ups14EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups14Battery 4 }
|
|
|
|
ups14BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups14Battery 5 }
|
|
|
|
ups14BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups14Battery 6 }
|
|
|
|
ups14BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups14Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups14Input OBJECT IDENTIFIER ::= { ups14Objects 3 }
|
|
|
|
ups14InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups14Input 1 }
|
|
|
|
|
|
ups14InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups14Input 2 }
|
|
|
|
ups14InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups14InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups14InputNumLines."
|
|
::= { ups14Input 3 }
|
|
|
|
ups14InputEntry OBJECT-TYPE
|
|
SYNTAX Ups14InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups14InputLineIndex }
|
|
::= { ups14InputTable 1 }
|
|
|
|
Ups14InputEntry ::= SEQUENCE {
|
|
ups14InputLineIndex PositiveInteger,
|
|
ups14InputFrequency NonNegativeInteger,
|
|
ups14InputVoltage NonNegativeInteger,
|
|
ups14InputCurrent NonNegativeInteger,
|
|
ups14InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups14InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups14InputEntry 1 }
|
|
|
|
ups14InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups14InputEntry 2 }
|
|
|
|
ups14InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups14InputEntry 3 }
|
|
|
|
ups14InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups14InputEntry 4 }
|
|
|
|
ups14InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups14InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups14Output OBJECT IDENTIFIER ::= { ups14Objects 4 }
|
|
|
|
ups14OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups14Output 1 }
|
|
|
|
ups14OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups14Output 2 }
|
|
|
|
ups14OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups14Output 3 }
|
|
|
|
ups14OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups14OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups14OutputNumLines."
|
|
::= { ups14Output 4 }
|
|
|
|
ups14OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups14OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups14OutputLineIndex }
|
|
::= { ups14OutputTable 1 }
|
|
|
|
Ups14OutputEntry ::= SEQUENCE {
|
|
ups14OutputLineIndex PositiveInteger,
|
|
ups14OutputVoltage NonNegativeInteger,
|
|
ups14OutputCurrent NonNegativeInteger,
|
|
ups14OutputPower NonNegativeInteger,
|
|
ups14OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups14OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups14OutputEntry 1 }
|
|
|
|
ups14OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups14OutputEntry 2 }
|
|
|
|
ups14OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups14OutputEntry 3 }
|
|
|
|
ups14OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups14OutputEntry 4 }
|
|
|
|
ups14OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups14OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups14Bypass OBJECT IDENTIFIER ::= { ups14Objects 5 }
|
|
|
|
ups14BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups14Bypass 1 }
|
|
|
|
ups14BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups14Bypass 2 }
|
|
|
|
ups14BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups14BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups14BypassNumLines."
|
|
::= { ups14Bypass 3 }
|
|
|
|
ups14BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups14BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups14BypassLineIndex }
|
|
::= { ups14BypassTable 1 }
|
|
|
|
Ups14BypassEntry ::= SEQUENCE {
|
|
ups14BypassLineIndex PositiveInteger,
|
|
ups14BypassVoltage NonNegativeInteger,
|
|
ups14BypassCurrent NonNegativeInteger,
|
|
ups14BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups14BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups14BypassEntry 1 }
|
|
|
|
ups14BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups14BypassEntry 2 }
|
|
|
|
ups14BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups14BypassEntry 3 }
|
|
|
|
ups14BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups14BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups14Alarm OBJECT IDENTIFIER ::= { ups14Objects 6 }
|
|
|
|
ups14AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups14Alarm 1 }
|
|
|
|
ups14AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups14AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups14AlarmId equal to 1, and increments the value of
|
|
ups14AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups14AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups14AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups14AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups14AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups14AlarmsPresent."
|
|
::= { ups14Alarm 2 }
|
|
|
|
ups14AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups14AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups14AlarmId }
|
|
::= { ups14AlarmTable 1 }
|
|
|
|
Ups14AlarmEntry ::= SEQUENCE {
|
|
ups14AlarmId PositiveInteger,
|
|
ups14AlarmDescr AutonomousType,
|
|
ups14AlarmTime TimeStamp
|
|
}
|
|
|
|
ups14AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups14AlarmEntry 1 }
|
|
|
|
ups14AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups14AlarmEntry 2 }
|
|
|
|
ups14AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups14AlarmTime shall equal
|
|
0."
|
|
::= { ups14AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups14WellKnownAlarms OBJECT IDENTIFIER ::= { ups14Alarm 3 }
|
|
ups14AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups14WellKnownAlarms 1 }
|
|
|
|
ups14AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups14WellKnownAlarms 2 }
|
|
|
|
ups14AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups14ConfigLowBattTime."
|
|
::= { ups14WellKnownAlarms 3 }
|
|
|
|
|
|
ups14AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups14WellKnownAlarms 4 }
|
|
|
|
ups14AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups14WellKnownAlarms 5 }
|
|
|
|
ups14AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups14WellKnownAlarms 6 }
|
|
|
|
ups14AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups14WellKnownAlarms 7 }
|
|
|
|
ups14AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups14WellKnownAlarms 8 }
|
|
|
|
ups14AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups14WellKnownAlarms 9 }
|
|
|
|
ups14AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups14WellKnownAlarms 10 }
|
|
|
|
ups14AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups14WellKnownAlarms 11 }
|
|
|
|
ups14AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups14WellKnownAlarms 12 }
|
|
|
|
ups14AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups14WellKnownAlarms 13 }
|
|
|
|
ups14AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups14WellKnownAlarms 14 }
|
|
|
|
ups14AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups14WellKnownAlarms 15 }
|
|
|
|
ups14AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups14WellKnownAlarms 16 }
|
|
|
|
ups14AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups14WellKnownAlarms 17 }
|
|
|
|
ups14AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups14WellKnownAlarms 18 }
|
|
|
|
ups14AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups14WellKnownAlarms 19 }
|
|
|
|
ups14AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups14WellKnownAlarms 20 }
|
|
|
|
ups14AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups14WellKnownAlarms 21 }
|
|
|
|
ups14AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups14ShutdownAfterDelay countdown is underway."
|
|
::= { ups14WellKnownAlarms 22 }
|
|
|
|
ups14AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups14WellKnownAlarms 23 }
|
|
|
|
ups14AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups14WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups14Test OBJECT IDENTIFIER ::= { ups14Objects 7 }
|
|
|
|
ups14TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups14TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups14TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups14TestId variable to
|
|
ups14TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups14TestNoTestsInitiated is returned."
|
|
::= { ups14Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups14TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups14TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups14TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups14TestResultsSummary */
|
|
get (upsTestSpinLock, ups14TestResultsSummary,
|
|
ups14TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups14TestResultsSummary,
|
|
ups14TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups14TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups14TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups14Test 2 }
|
|
|
|
ups14TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups14TestId to ups14TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups14Test 3 }
|
|
|
|
ups14TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups14TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups14Test 4 }
|
|
|
|
ups14TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups14TestResultsSummary is noTestsInitiated(6),
|
|
ups14TestStartTime has the value 0."
|
|
::= { ups14Test 5 }
|
|
|
|
ups14TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups14TestResultsSummary is noTestsInitiated(6),
|
|
ups14TestElapsedTime has the value 0."
|
|
::= { ups14Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups14WellKnownTests OBJECT IDENTIFIER ::= { ups14Test 7 }
|
|
|
|
|
|
ups14TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups14WellKnownTests 1 }
|
|
|
|
ups14TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups14WellKnownTests 2 }
|
|
|
|
ups14TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups14WellKnownTests 3 }
|
|
|
|
ups14TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups14WellKnownTests 4 }
|
|
|
|
ups14TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups14WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups14Control OBJECT IDENTIFIER ::= { ups14Objects 8 }
|
|
|
|
ups14ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups14ShutdownAfterDelay and ups14RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups14Control 1 }
|
|
|
|
ups14ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups14ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups14ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups14ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups14ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups14ShutdownAfterDelay already in effect."
|
|
::= { ups14Control 2 }
|
|
|
|
ups14StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups14StartupAfterDelay
|
|
countdown or ups14RebootWithDuration countdown in
|
|
progress. When read, ups14StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups14Control 3 }
|
|
|
|
ups14RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups14ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups14RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups14Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups14Traps OBJECT IDENTIFIER ::= { upsModule14 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups14TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups14EstimatedMinutesRemaining, ups14SecondsOnBattery,
|
|
ups14ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups14Traps 1 }
|
|
|
|
ups14TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups14TestId, ups14TestSpinLock,
|
|
ups14TestResultsSummary, ups14TestResultsDetail,
|
|
ups14TestStartTime, ups14TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups14Traps 2 }
|
|
|
|
ups14TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups14AlarmId, ups14AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups14AlarmOnBattery and
|
|
ups14AlarmTestInProgress."
|
|
::= { ups14Traps 3 }
|
|
|
|
ups14TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups14AlarmId, ups14AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups14AlarmTestInProgress."
|
|
::= { ups14Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups14Conformance OBJECT IDENTIFIER ::= { upsModule14 3 }
|
|
|
|
ups14Compliances OBJECT IDENTIFIER ::= { ups14Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups14SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups14SubsetIdentGroup,
|
|
ups14SubsetBatteryGroup, ups14SubsetInputGroup,
|
|
ups14SubsetOutputGroup, ups14SubsetAlarmGroup,
|
|
ups14SubsetControlGroup }
|
|
|
|
OBJECT ups14BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups14AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups14AlarmOnBattery, ups14AlarmLowBattery,
|
|
ups14AlarmInputBad, ups14AlarmUpsOutputOff,
|
|
ups14AlarmUpsSystemOff, and ups14AlarmTestInProgress."
|
|
|
|
OBJECT ups14OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups14ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups14Compliances 1 }
|
|
|
|
ups14BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups14BasicIdentGroup,
|
|
ups14BasicBatteryGroup, ups14BasicInputGroup,
|
|
ups14BasicOutputGroup, ups14BasicAlarmGroup,
|
|
ups14BasicTestGroup, ups14BasicControlGroup }
|
|
|
|
|
|
OBJECT ups14AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups14AlarmOnBattery, ups14AlarmLowBattery,
|
|
ups14AlarmDepletedBattery, ups14AlarmTempBad,
|
|
ups14AlarmInputBad, ups14AlarmOutputOverload,
|
|
ups14AlarmOnBypass, ups14AlarmBypassBad,
|
|
ups14AlarmOutputOffAsRequested,
|
|
ups14AlarmUpsOffAsRequested, ups14AlarmUpsOutputOff,
|
|
ups14AlarmUpsSystemOff, ups14AlarmGeneralFault,
|
|
ups14AlarmDiagnosticTestFailed,
|
|
ups14AlarmCommunicationsLost, ups14AlarmShutdownPending,
|
|
and ups14AlarmTestInProgress."
|
|
|
|
OBJECT ups14TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups14TestNoTestsInitiated."
|
|
|
|
OBJECT ups14OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups14BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups14BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups14ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups14Compliances 2 }
|
|
|
|
ups14FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups14FullIdentGroup, ups14FullBatteryGroup,
|
|
ups14FullInputGroup, ups14FullOutputGroup,
|
|
ups14FullAlarmGroup, ups14FullTestGroup,
|
|
ups14FullControlGroup }
|
|
|
|
OBJECT ups14AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups14AlarmBatteryBad, ups14AlarmOnBattery,
|
|
ups14AlarmLowBattery, ups14AlarmDepletedBattery,
|
|
ups14AlarmTempBad, ups14AlarmInputBad, ups14AlarmOnBypass,
|
|
ups14AlarmBypassBad, ups14AlarmOutputOffAsRequested,
|
|
ups14AlarmUpsOffAsRequested, ups14AlarmUpsOutputOff,
|
|
ups14AlarmUpsSystemOff, ups14AlarmGeneralFault,
|
|
ups14AlarmDiagnosticTestFailed,
|
|
ups14AlarmCommunicationsLost, ups14AlarmShutdownPending,
|
|
and ups14AlarmTestInProgress."
|
|
|
|
OBJECT ups14TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups14TestNoTestsInitiated,
|
|
ups14TestGeneralSystemsTest, and
|
|
ups14TestQuickBatteryTest."
|
|
|
|
OBJECT ups14OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups14FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups14FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups14ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups14Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups14Groups OBJECT IDENTIFIER ::= { ups14Conformance 2 }
|
|
|
|
ups14SubsetGroups OBJECT IDENTIFIER ::= { ups14Groups 1 }
|
|
|
|
ups14SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups14IdentManufacturer, ups14IdentModel,
|
|
ups14IdentAgentSoftwareVersion, ups14IdentName,
|
|
ups14IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups14SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups14SubsetGroups 1 }
|
|
|
|
ups14SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups14BatteryStatus, ups14SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups14SubsetGroups 2 }
|
|
|
|
ups14SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups14InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups14SubsetGroups 3 }
|
|
|
|
ups14SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups14OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups14SubsetGroups 4 }
|
|
|
|
|
|
-- { ups14SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups14SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups14AlarmsPresent, ups14AlarmDescr, ups14AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups14SubsetGroups 6 }
|
|
|
|
-- { ups14SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups14SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups14ShutdownType, ups14ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups14SubsetGroups 8 }
|
|
|
|
ups14BasicGroups OBJECT IDENTIFIER ::= { ups14Groups 2 }
|
|
|
|
ups14BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups14IdentManufacturer, ups14IdentModel,
|
|
ups14IdentUPSSoftwareVersion,
|
|
ups14IdentAgentSoftwareVersion, ups14IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 1 }
|
|
|
|
ups14BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups14BatteryStatus, ups14SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 2 }
|
|
|
|
ups14BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups14InputLineBads, ups14InputNumLines,
|
|
ups14InputFrequency, ups14InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 3 }
|
|
|
|
ups14BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups14OutputSource, ups14OutputFrequency,
|
|
ups14OutputNumLines, ups14OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 4 }
|
|
|
|
ups14BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups14BypassFrequency, ups14BypassNumLines,
|
|
ups14BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 5 }
|
|
|
|
ups14BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups14AlarmsPresent, ups14AlarmDescr, ups14AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups14BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 6 }
|
|
|
|
ups14BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups14TestId, ups14TestSpinLock,
|
|
ups14TestResultsSummary, ups14TestResultsDetail,
|
|
ups14TestStartTime, ups14TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 7 }
|
|
|
|
ups14BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups14ShutdownType, ups14ShutdownAfterDelay,
|
|
ups14StartupAfterDelay, ups14RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups14BasicGroups 8 }
|
|
|
|
ups14FullGroups OBJECT IDENTIFIER ::= { ups14Groups 3 }
|
|
|
|
ups14FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups14IdentManufacturer, ups14IdentModel,
|
|
ups14IdentUPSSoftwareVersion,
|
|
ups14IdentAgentSoftwareVersion, ups14IdentName,
|
|
ups14IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups14FullGroups 1 }
|
|
|
|
ups14FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups14BatteryStatus, ups14SecondsOnBattery,
|
|
ups14EstimatedMinutesRemaining,
|
|
ups14EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 2 }
|
|
|
|
ups14FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups14InputLineBads, ups14InputNumLines,
|
|
ups14InputFrequency, ups14InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 3 }
|
|
|
|
ups14FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups14OutputSource, ups14OutputFrequency,
|
|
ups14OutputNumLines, ups14OutputVoltage,
|
|
ups14OutputCurrent, ups14OutputPower,
|
|
ups14OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 4 }
|
|
|
|
ups14FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups14BypassFrequency, ups14BypassNumLines,
|
|
ups14BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 5 }
|
|
|
|
ups14FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups14AlarmsPresent, ups14AlarmDescr, ups14AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups14FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 6 }
|
|
|
|
ups14FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups14TestId, ups14TestSpinLock,
|
|
ups14TestResultsSummary, ups14TestResultsDetail,
|
|
ups14TestStartTime, ups14TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 7 }
|
|
|
|
ups14FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups14ShutdownType, ups14ShutdownAfterDelay,
|
|
ups14StartupAfterDelay, ups14RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups14FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups14FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 15 data
|
|
--
|
|
|
|
upsModule15 OBJECT IDENTIFIER ::= { upsModular 16 }
|
|
ups15Objects OBJECT IDENTIFIER ::= { upsModule15 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups15IdentName and
|
|
-- ups15IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups15Ident OBJECT IDENTIFIER ::= { ups15Objects 1 }
|
|
|
|
ups15IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups15Ident 1 }
|
|
|
|
ups15IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups15Ident 2 }
|
|
|
|
ups15IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups15IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups15Ident 3 }
|
|
|
|
ups15IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups15IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups15Ident 4 }
|
|
|
|
ups15IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups15Ident 5 }
|
|
|
|
ups15IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups15Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups15Battery OBJECT IDENTIFIER ::= { ups15Objects 2 }
|
|
|
|
ups15BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups15ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups15ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups15Battery 1 }
|
|
|
|
ups15SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups15Battery 2 }
|
|
|
|
ups15EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups15Battery 3 }
|
|
|
|
ups15EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups15Battery 4 }
|
|
|
|
ups15BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups15Battery 5 }
|
|
|
|
ups15BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups15Battery 6 }
|
|
|
|
ups15BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups15Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups15Input OBJECT IDENTIFIER ::= { ups15Objects 3 }
|
|
|
|
ups15InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups15Input 1 }
|
|
|
|
|
|
ups15InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups15Input 2 }
|
|
|
|
ups15InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups15InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups15InputNumLines."
|
|
::= { ups15Input 3 }
|
|
|
|
ups15InputEntry OBJECT-TYPE
|
|
SYNTAX Ups15InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups15InputLineIndex }
|
|
::= { ups15InputTable 1 }
|
|
|
|
Ups15InputEntry ::= SEQUENCE {
|
|
ups15InputLineIndex PositiveInteger,
|
|
ups15InputFrequency NonNegativeInteger,
|
|
ups15InputVoltage NonNegativeInteger,
|
|
ups15InputCurrent NonNegativeInteger,
|
|
ups15InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups15InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups15InputEntry 1 }
|
|
|
|
ups15InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups15InputEntry 2 }
|
|
|
|
ups15InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups15InputEntry 3 }
|
|
|
|
ups15InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups15InputEntry 4 }
|
|
|
|
ups15InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups15InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups15Output OBJECT IDENTIFIER ::= { ups15Objects 4 }
|
|
|
|
ups15OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups15Output 1 }
|
|
|
|
ups15OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups15Output 2 }
|
|
|
|
ups15OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups15Output 3 }
|
|
|
|
ups15OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups15OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups15OutputNumLines."
|
|
::= { ups15Output 4 }
|
|
|
|
ups15OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups15OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups15OutputLineIndex }
|
|
::= { ups15OutputTable 1 }
|
|
|
|
Ups15OutputEntry ::= SEQUENCE {
|
|
ups15OutputLineIndex PositiveInteger,
|
|
ups15OutputVoltage NonNegativeInteger,
|
|
ups15OutputCurrent NonNegativeInteger,
|
|
ups15OutputPower NonNegativeInteger,
|
|
ups15OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups15OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups15OutputEntry 1 }
|
|
|
|
ups15OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups15OutputEntry 2 }
|
|
|
|
ups15OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups15OutputEntry 3 }
|
|
|
|
ups15OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups15OutputEntry 4 }
|
|
|
|
ups15OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups15OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups15Bypass OBJECT IDENTIFIER ::= { ups15Objects 5 }
|
|
|
|
ups15BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups15Bypass 1 }
|
|
|
|
ups15BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups15Bypass 2 }
|
|
|
|
ups15BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups15BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups15BypassNumLines."
|
|
::= { ups15Bypass 3 }
|
|
|
|
ups15BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups15BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups15BypassLineIndex }
|
|
::= { ups15BypassTable 1 }
|
|
|
|
Ups15BypassEntry ::= SEQUENCE {
|
|
ups15BypassLineIndex PositiveInteger,
|
|
ups15BypassVoltage NonNegativeInteger,
|
|
ups15BypassCurrent NonNegativeInteger,
|
|
ups15BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups15BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups15BypassEntry 1 }
|
|
|
|
ups15BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups15BypassEntry 2 }
|
|
|
|
ups15BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups15BypassEntry 3 }
|
|
|
|
ups15BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups15BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups15Alarm OBJECT IDENTIFIER ::= { ups15Objects 6 }
|
|
|
|
ups15AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups15Alarm 1 }
|
|
|
|
ups15AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups15AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups15AlarmId equal to 1, and increments the value of
|
|
ups15AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups15AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups15AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups15AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups15AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups15AlarmsPresent."
|
|
::= { ups15Alarm 2 }
|
|
|
|
ups15AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups15AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups15AlarmId }
|
|
::= { ups15AlarmTable 1 }
|
|
|
|
Ups15AlarmEntry ::= SEQUENCE {
|
|
ups15AlarmId PositiveInteger,
|
|
ups15AlarmDescr AutonomousType,
|
|
ups15AlarmTime TimeStamp
|
|
}
|
|
|
|
ups15AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups15AlarmEntry 1 }
|
|
|
|
ups15AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups15AlarmEntry 2 }
|
|
|
|
ups15AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups15AlarmTime shall equal
|
|
0."
|
|
::= { ups15AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups15WellKnownAlarms OBJECT IDENTIFIER ::= { ups15Alarm 3 }
|
|
ups15AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups15WellKnownAlarms 1 }
|
|
|
|
ups15AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups15WellKnownAlarms 2 }
|
|
|
|
ups15AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups15ConfigLowBattTime."
|
|
::= { ups15WellKnownAlarms 3 }
|
|
|
|
|
|
ups15AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups15WellKnownAlarms 4 }
|
|
|
|
ups15AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups15WellKnownAlarms 5 }
|
|
|
|
ups15AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups15WellKnownAlarms 6 }
|
|
|
|
ups15AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups15WellKnownAlarms 7 }
|
|
|
|
ups15AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups15WellKnownAlarms 8 }
|
|
|
|
ups15AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups15WellKnownAlarms 9 }
|
|
|
|
ups15AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups15WellKnownAlarms 10 }
|
|
|
|
ups15AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups15WellKnownAlarms 11 }
|
|
|
|
ups15AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups15WellKnownAlarms 12 }
|
|
|
|
ups15AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups15WellKnownAlarms 13 }
|
|
|
|
ups15AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups15WellKnownAlarms 14 }
|
|
|
|
ups15AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups15WellKnownAlarms 15 }
|
|
|
|
ups15AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups15WellKnownAlarms 16 }
|
|
|
|
ups15AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups15WellKnownAlarms 17 }
|
|
|
|
ups15AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups15WellKnownAlarms 18 }
|
|
|
|
ups15AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups15WellKnownAlarms 19 }
|
|
|
|
ups15AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups15WellKnownAlarms 20 }
|
|
|
|
ups15AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups15WellKnownAlarms 21 }
|
|
|
|
ups15AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups15ShutdownAfterDelay countdown is underway."
|
|
::= { ups15WellKnownAlarms 22 }
|
|
|
|
ups15AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups15WellKnownAlarms 23 }
|
|
|
|
ups15AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups15WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups15Test OBJECT IDENTIFIER ::= { ups15Objects 7 }
|
|
|
|
ups15TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups15TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups15TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups15TestId variable to
|
|
ups15TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups15TestNoTestsInitiated is returned."
|
|
::= { ups15Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups15TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups15TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups15TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups15TestResultsSummary */
|
|
get (upsTestSpinLock, ups15TestResultsSummary,
|
|
ups15TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups15TestResultsSummary,
|
|
ups15TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups15TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups15TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups15Test 2 }
|
|
|
|
ups15TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups15TestId to ups15TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups15Test 3 }
|
|
|
|
ups15TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups15TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups15Test 4 }
|
|
|
|
ups15TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups15TestResultsSummary is noTestsInitiated(6),
|
|
ups15TestStartTime has the value 0."
|
|
::= { ups15Test 5 }
|
|
|
|
ups15TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups15TestResultsSummary is noTestsInitiated(6),
|
|
ups15TestElapsedTime has the value 0."
|
|
::= { ups15Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups15WellKnownTests OBJECT IDENTIFIER ::= { ups15Test 7 }
|
|
|
|
|
|
ups15TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups15WellKnownTests 1 }
|
|
|
|
ups15TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups15WellKnownTests 2 }
|
|
|
|
ups15TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups15WellKnownTests 3 }
|
|
|
|
ups15TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups15WellKnownTests 4 }
|
|
|
|
ups15TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups15WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups15Control OBJECT IDENTIFIER ::= { ups15Objects 8 }
|
|
|
|
ups15ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups15ShutdownAfterDelay and ups15RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups15Control 1 }
|
|
|
|
ups15ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups15ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups15ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups15ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups15ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups15ShutdownAfterDelay already in effect."
|
|
::= { ups15Control 2 }
|
|
|
|
ups15StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups15StartupAfterDelay
|
|
countdown or ups15RebootWithDuration countdown in
|
|
progress. When read, ups15StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups15Control 3 }
|
|
|
|
ups15RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups15ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups15RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups15Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups15Traps OBJECT IDENTIFIER ::= { upsModule15 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups15TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups15EstimatedMinutesRemaining, ups15SecondsOnBattery,
|
|
ups15ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups15Traps 1 }
|
|
|
|
ups15TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups15TestId, ups15TestSpinLock,
|
|
ups15TestResultsSummary, ups15TestResultsDetail,
|
|
ups15TestStartTime, ups15TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups15Traps 2 }
|
|
|
|
ups15TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups15AlarmId, ups15AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups15AlarmOnBattery and
|
|
ups15AlarmTestInProgress."
|
|
::= { ups15Traps 3 }
|
|
|
|
ups15TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups15AlarmId, ups15AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups15AlarmTestInProgress."
|
|
::= { ups15Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups15Conformance OBJECT IDENTIFIER ::= { upsModule15 3 }
|
|
|
|
ups15Compliances OBJECT IDENTIFIER ::= { ups15Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups15SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups15SubsetIdentGroup,
|
|
ups15SubsetBatteryGroup, ups15SubsetInputGroup,
|
|
ups15SubsetOutputGroup, ups15SubsetAlarmGroup,
|
|
ups15SubsetControlGroup }
|
|
|
|
OBJECT ups15BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups15AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups15AlarmOnBattery, ups15AlarmLowBattery,
|
|
ups15AlarmInputBad, ups15AlarmUpsOutputOff,
|
|
ups15AlarmUpsSystemOff, and ups15AlarmTestInProgress."
|
|
|
|
OBJECT ups15OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups15ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups15Compliances 1 }
|
|
|
|
ups15BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups15BasicIdentGroup,
|
|
ups15BasicBatteryGroup, ups15BasicInputGroup,
|
|
ups15BasicOutputGroup, ups15BasicAlarmGroup,
|
|
ups15BasicTestGroup, ups15BasicControlGroup }
|
|
|
|
OBJECT ups15AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups15AlarmOnBattery, ups15AlarmLowBattery,
|
|
ups15AlarmDepletedBattery, ups15AlarmTempBad,
|
|
ups15AlarmInputBad, ups15AlarmOutputOverload,
|
|
ups15AlarmOnBypass, ups15AlarmBypassBad,
|
|
ups15AlarmOutputOffAsRequested,
|
|
ups15AlarmUpsOffAsRequested, ups15AlarmUpsOutputOff,
|
|
ups15AlarmUpsSystemOff, ups15AlarmGeneralFault,
|
|
ups15AlarmDiagnosticTestFailed,
|
|
ups15AlarmCommunicationsLost, ups15AlarmShutdownPending,
|
|
and ups15AlarmTestInProgress."
|
|
|
|
OBJECT ups15TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups15TestNoTestsInitiated."
|
|
|
|
OBJECT ups15OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups15BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups15BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups15ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups15Compliances 2 }
|
|
|
|
ups15FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups15FullIdentGroup, ups15FullBatteryGroup,
|
|
ups15FullInputGroup, ups15FullOutputGroup,
|
|
ups15FullAlarmGroup, ups15FullTestGroup,
|
|
ups15FullControlGroup }
|
|
|
|
OBJECT ups15AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups15AlarmBatteryBad, ups15AlarmOnBattery,
|
|
ups15AlarmLowBattery, ups15AlarmDepletedBattery,
|
|
ups15AlarmTempBad, ups15AlarmInputBad, ups15AlarmOnBypass,
|
|
ups15AlarmBypassBad, ups15AlarmOutputOffAsRequested,
|
|
ups15AlarmUpsOffAsRequested, ups15AlarmUpsOutputOff,
|
|
ups15AlarmUpsSystemOff, ups15AlarmGeneralFault,
|
|
ups15AlarmDiagnosticTestFailed,
|
|
ups15AlarmCommunicationsLost, ups15AlarmShutdownPending,
|
|
and ups15AlarmTestInProgress."
|
|
|
|
OBJECT ups15TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups15TestNoTestsInitiated,
|
|
ups15TestGeneralSystemsTest, and
|
|
ups15TestQuickBatteryTest."
|
|
|
|
OBJECT ups15OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups15FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups15FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups15ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups15Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups15Groups OBJECT IDENTIFIER ::= { ups15Conformance 2 }
|
|
|
|
ups15SubsetGroups OBJECT IDENTIFIER ::= { ups15Groups 1 }
|
|
|
|
ups15SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups15IdentManufacturer, ups15IdentModel,
|
|
ups15IdentAgentSoftwareVersion, ups15IdentName,
|
|
ups15IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups15SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups15SubsetGroups 1 }
|
|
|
|
ups15SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups15BatteryStatus, ups15SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups15SubsetGroups 2 }
|
|
|
|
ups15SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups15InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups15SubsetGroups 3 }
|
|
|
|
ups15SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups15OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups15SubsetGroups 4 }
|
|
|
|
|
|
-- { ups15SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups15SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups15AlarmsPresent, ups15AlarmDescr, ups15AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups15SubsetGroups 6 }
|
|
|
|
-- { ups15SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups15SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups15ShutdownType, ups15ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups15SubsetGroups 8 }
|
|
|
|
ups15BasicGroups OBJECT IDENTIFIER ::= { ups15Groups 2 }
|
|
|
|
ups15BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups15IdentManufacturer, ups15IdentModel,
|
|
ups15IdentUPSSoftwareVersion,
|
|
ups15IdentAgentSoftwareVersion, ups15IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 1 }
|
|
|
|
ups15BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups15BatteryStatus, ups15SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 2 }
|
|
|
|
ups15BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups15InputLineBads, ups15InputNumLines,
|
|
ups15InputFrequency, ups15InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 3 }
|
|
|
|
ups15BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups15OutputSource, ups15OutputFrequency,
|
|
ups15OutputNumLines, ups15OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 4 }
|
|
|
|
ups15BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups15BypassFrequency, ups15BypassNumLines,
|
|
ups15BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 5 }
|
|
|
|
ups15BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups15AlarmsPresent, ups15AlarmDescr, ups15AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups15BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 6 }
|
|
|
|
ups15BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups15TestId, ups15TestSpinLock,
|
|
ups15TestResultsSummary, ups15TestResultsDetail,
|
|
ups15TestStartTime, ups15TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 7 }
|
|
|
|
ups15BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups15ShutdownType, ups15ShutdownAfterDelay,
|
|
ups15StartupAfterDelay, ups15RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups15BasicGroups 8 }
|
|
|
|
ups15FullGroups OBJECT IDENTIFIER ::= { ups15Groups 3 }
|
|
|
|
ups15FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups15IdentManufacturer, ups15IdentModel,
|
|
ups15IdentUPSSoftwareVersion,
|
|
ups15IdentAgentSoftwareVersion, ups15IdentName,
|
|
ups15IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups15FullGroups 1 }
|
|
|
|
ups15FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups15BatteryStatus, ups15SecondsOnBattery,
|
|
ups15EstimatedMinutesRemaining,
|
|
ups15EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 2 }
|
|
|
|
ups15FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups15InputLineBads, ups15InputNumLines,
|
|
ups15InputFrequency, ups15InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 3 }
|
|
|
|
ups15FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups15OutputSource, ups15OutputFrequency,
|
|
ups15OutputNumLines, ups15OutputVoltage,
|
|
ups15OutputCurrent, ups15OutputPower,
|
|
ups15OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 4 }
|
|
|
|
ups15FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups15BypassFrequency, ups15BypassNumLines,
|
|
ups15BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 5 }
|
|
|
|
ups15FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups15AlarmsPresent, ups15AlarmDescr, ups15AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups15FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 6 }
|
|
|
|
ups15FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups15TestId, ups15TestSpinLock,
|
|
ups15TestResultsSummary, ups15TestResultsDetail,
|
|
ups15TestStartTime, ups15TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 7 }
|
|
|
|
ups15FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups15ShutdownType, ups15ShutdownAfterDelay,
|
|
ups15StartupAfterDelay, ups15RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups15FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups15FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 16 data
|
|
--
|
|
|
|
upsModule16 OBJECT IDENTIFIER ::= { upsModular 17 }
|
|
ups16Objects OBJECT IDENTIFIER ::= { upsModule16 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups16IdentName and
|
|
-- ups16IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups16Ident OBJECT IDENTIFIER ::= { ups16Objects 1 }
|
|
|
|
ups16IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups16Ident 1 }
|
|
|
|
ups16IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups16Ident 2 }
|
|
|
|
ups16IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups16IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups16Ident 3 }
|
|
|
|
ups16IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups16IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups16Ident 4 }
|
|
|
|
ups16IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups16Ident 5 }
|
|
|
|
ups16IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups16Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups16Battery OBJECT IDENTIFIER ::= { ups16Objects 2 }
|
|
|
|
ups16BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups16ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups16ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups16Battery 1 }
|
|
|
|
ups16SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups16Battery 2 }
|
|
|
|
ups16EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups16Battery 3 }
|
|
|
|
ups16EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups16Battery 4 }
|
|
|
|
ups16BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups16Battery 5 }
|
|
|
|
ups16BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups16Battery 6 }
|
|
|
|
ups16BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups16Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups16Input OBJECT IDENTIFIER ::= { ups16Objects 3 }
|
|
|
|
ups16InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups16Input 1 }
|
|
|
|
|
|
ups16InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups16Input 2 }
|
|
|
|
ups16InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups16InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups16InputNumLines."
|
|
::= { ups16Input 3 }
|
|
|
|
ups16InputEntry OBJECT-TYPE
|
|
SYNTAX Ups16InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups16InputLineIndex }
|
|
::= { ups16InputTable 1 }
|
|
|
|
Ups16InputEntry ::= SEQUENCE {
|
|
ups16InputLineIndex PositiveInteger,
|
|
ups16InputFrequency NonNegativeInteger,
|
|
ups16InputVoltage NonNegativeInteger,
|
|
ups16InputCurrent NonNegativeInteger,
|
|
ups16InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups16InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups16InputEntry 1 }
|
|
|
|
ups16InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups16InputEntry 2 }
|
|
|
|
ups16InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups16InputEntry 3 }
|
|
|
|
ups16InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups16InputEntry 4 }
|
|
|
|
ups16InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups16InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups16Output OBJECT IDENTIFIER ::= { ups16Objects 4 }
|
|
|
|
ups16OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups16Output 1 }
|
|
|
|
ups16OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups16Output 2 }
|
|
|
|
ups16OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups16Output 3 }
|
|
|
|
ups16OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups16OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups16OutputNumLines."
|
|
::= { ups16Output 4 }
|
|
|
|
ups16OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups16OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups16OutputLineIndex }
|
|
::= { ups16OutputTable 1 }
|
|
|
|
Ups16OutputEntry ::= SEQUENCE {
|
|
ups16OutputLineIndex PositiveInteger,
|
|
ups16OutputVoltage NonNegativeInteger,
|
|
ups16OutputCurrent NonNegativeInteger,
|
|
ups16OutputPower NonNegativeInteger,
|
|
ups16OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups16OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups16OutputEntry 1 }
|
|
|
|
ups16OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups16OutputEntry 2 }
|
|
|
|
ups16OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups16OutputEntry 3 }
|
|
|
|
ups16OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups16OutputEntry 4 }
|
|
|
|
ups16OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups16OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups16Bypass OBJECT IDENTIFIER ::= { ups16Objects 5 }
|
|
|
|
ups16BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups16Bypass 1 }
|
|
|
|
ups16BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups16Bypass 2 }
|
|
|
|
ups16BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups16BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups16BypassNumLines."
|
|
::= { ups16Bypass 3 }
|
|
|
|
ups16BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups16BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups16BypassLineIndex }
|
|
::= { ups16BypassTable 1 }
|
|
|
|
Ups16BypassEntry ::= SEQUENCE {
|
|
ups16BypassLineIndex PositiveInteger,
|
|
ups16BypassVoltage NonNegativeInteger,
|
|
ups16BypassCurrent NonNegativeInteger,
|
|
ups16BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups16BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups16BypassEntry 1 }
|
|
|
|
ups16BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups16BypassEntry 2 }
|
|
|
|
ups16BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups16BypassEntry 3 }
|
|
|
|
ups16BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups16BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups16Alarm OBJECT IDENTIFIER ::= { ups16Objects 6 }
|
|
|
|
ups16AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups16Alarm 1 }
|
|
|
|
ups16AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups16AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups16AlarmId equal to 1, and increments the value of
|
|
ups16AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups16AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups16AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups16AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups16AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups16AlarmsPresent."
|
|
::= { ups16Alarm 2 }
|
|
|
|
ups16AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups16AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups16AlarmId }
|
|
::= { ups16AlarmTable 1 }
|
|
|
|
Ups16AlarmEntry ::= SEQUENCE {
|
|
ups16AlarmId PositiveInteger,
|
|
ups16AlarmDescr AutonomousType,
|
|
ups16AlarmTime TimeStamp
|
|
}
|
|
|
|
ups16AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups16AlarmEntry 1 }
|
|
|
|
ups16AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups16AlarmEntry 2 }
|
|
|
|
ups16AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups16AlarmTime shall equal
|
|
0."
|
|
::= { ups16AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups16WellKnownAlarms OBJECT IDENTIFIER ::= { ups16Alarm 3 }
|
|
ups16AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups16WellKnownAlarms 1 }
|
|
|
|
ups16AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups16WellKnownAlarms 2 }
|
|
|
|
ups16AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups16ConfigLowBattTime."
|
|
::= { ups16WellKnownAlarms 3 }
|
|
|
|
|
|
ups16AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups16WellKnownAlarms 4 }
|
|
|
|
ups16AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups16WellKnownAlarms 5 }
|
|
|
|
ups16AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups16WellKnownAlarms 6 }
|
|
|
|
ups16AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups16WellKnownAlarms 7 }
|
|
|
|
ups16AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups16WellKnownAlarms 8 }
|
|
|
|
ups16AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups16WellKnownAlarms 9 }
|
|
|
|
ups16AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups16WellKnownAlarms 10 }
|
|
|
|
ups16AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups16WellKnownAlarms 11 }
|
|
|
|
ups16AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups16WellKnownAlarms 12 }
|
|
|
|
ups16AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups16WellKnownAlarms 13 }
|
|
|
|
ups16AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups16WellKnownAlarms 14 }
|
|
|
|
ups16AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups16WellKnownAlarms 15 }
|
|
|
|
ups16AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups16WellKnownAlarms 16 }
|
|
|
|
ups16AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups16WellKnownAlarms 17 }
|
|
|
|
ups16AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups16WellKnownAlarms 18 }
|
|
|
|
ups16AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups16WellKnownAlarms 19 }
|
|
|
|
ups16AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups16WellKnownAlarms 20 }
|
|
|
|
ups16AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups16WellKnownAlarms 21 }
|
|
|
|
ups16AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups16ShutdownAfterDelay countdown is underway."
|
|
::= { ups16WellKnownAlarms 22 }
|
|
|
|
ups16AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups16WellKnownAlarms 23 }
|
|
|
|
ups16AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups16WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups16Test OBJECT IDENTIFIER ::= { ups16Objects 7 }
|
|
|
|
ups16TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups16TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups16TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups16TestId variable to
|
|
ups16TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups16TestNoTestsInitiated is returned."
|
|
::= { ups16Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups16TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups16TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups16TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups16TestResultsSummary */
|
|
get (upsTestSpinLock, ups16TestResultsSummary,
|
|
ups16TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups16TestResultsSummary,
|
|
ups16TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups16TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups16TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups16Test 2 }
|
|
|
|
ups16TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups16TestId to ups16TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups16Test 3 }
|
|
|
|
ups16TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups16TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups16Test 4 }
|
|
|
|
ups16TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups16TestResultsSummary is noTestsInitiated(6),
|
|
ups16TestStartTime has the value 0."
|
|
::= { ups16Test 5 }
|
|
|
|
ups16TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups16TestResultsSummary is noTestsInitiated(6),
|
|
ups16TestElapsedTime has the value 0."
|
|
::= { ups16Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups16WellKnownTests OBJECT IDENTIFIER ::= { ups16Test 7 }
|
|
|
|
|
|
ups16TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups16WellKnownTests 1 }
|
|
|
|
ups16TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups16WellKnownTests 2 }
|
|
|
|
ups16TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups16WellKnownTests 3 }
|
|
|
|
ups16TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups16WellKnownTests 4 }
|
|
|
|
ups16TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups16WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups16Control OBJECT IDENTIFIER ::= { ups16Objects 8 }
|
|
|
|
ups16ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups16ShutdownAfterDelay and ups16RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups16Control 1 }
|
|
|
|
ups16ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups16ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups16ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups16ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups16ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups16ShutdownAfterDelay already in effect."
|
|
::= { ups16Control 2 }
|
|
|
|
ups16StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups16StartupAfterDelay
|
|
countdown or ups16RebootWithDuration countdown in
|
|
progress. When read, ups16StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups16Control 3 }
|
|
|
|
ups16RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups16ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups16RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups16Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups16Traps OBJECT IDENTIFIER ::= { upsModule16 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups16TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups16EstimatedMinutesRemaining, ups16SecondsOnBattery,
|
|
ups16ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups16Traps 1 }
|
|
|
|
ups16TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups16TestId, ups16TestSpinLock,
|
|
ups16TestResultsSummary, ups16TestResultsDetail,
|
|
ups16TestStartTime, ups16TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups16Traps 2 }
|
|
|
|
ups16TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups16AlarmId, ups16AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups16AlarmOnBattery and
|
|
ups16AlarmTestInProgress."
|
|
::= { ups16Traps 3 }
|
|
|
|
ups16TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups16AlarmId, ups16AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups16AlarmTestInProgress."
|
|
::= { ups16Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups16Conformance OBJECT IDENTIFIER ::= { upsModule16 3 }
|
|
|
|
ups16Compliances OBJECT IDENTIFIER ::= { ups16Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups16SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups16SubsetIdentGroup,
|
|
ups16SubsetBatteryGroup, ups16SubsetInputGroup,
|
|
ups16SubsetOutputGroup, ups16SubsetAlarmGroup,
|
|
ups16SubsetControlGroup }
|
|
|
|
OBJECT ups16BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups16AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups16AlarmOnBattery, ups16AlarmLowBattery,
|
|
ups16AlarmInputBad, ups16AlarmUpsOutputOff,
|
|
ups16AlarmUpsSystemOff, and ups16AlarmTestInProgress."
|
|
|
|
OBJECT ups16OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups16ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups16Compliances 1 }
|
|
|
|
ups16BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups16BasicIdentGroup,
|
|
ups16BasicBatteryGroup, ups16BasicInputGroup,
|
|
ups16BasicOutputGroup, ups16BasicAlarmGroup,
|
|
ups16BasicTestGroup, ups16BasicControlGroup }
|
|
|
|
OBJECT ups16AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups16AlarmOnBattery, ups16AlarmLowBattery,
|
|
ups16AlarmDepletedBattery, ups16AlarmTempBad,
|
|
ups16AlarmInputBad, ups16AlarmOutputOverload,
|
|
ups16AlarmOnBypass, ups16AlarmBypassBad,
|
|
ups16AlarmOutputOffAsRequested,
|
|
ups16AlarmUpsOffAsRequested, ups16AlarmUpsOutputOff,
|
|
ups16AlarmUpsSystemOff, ups16AlarmGeneralFault,
|
|
ups16AlarmDiagnosticTestFailed,
|
|
ups16AlarmCommunicationsLost, ups16AlarmShutdownPending,
|
|
and ups16AlarmTestInProgress."
|
|
|
|
OBJECT ups16TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups16TestNoTestsInitiated."
|
|
|
|
OBJECT ups16OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups16BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups16BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups16ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups16Compliances 2 }
|
|
|
|
ups16FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups16FullIdentGroup, ups16FullBatteryGroup,
|
|
ups16FullInputGroup, ups16FullOutputGroup,
|
|
ups16FullAlarmGroup, ups16FullTestGroup,
|
|
ups16FullControlGroup }
|
|
|
|
OBJECT ups16AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups16AlarmBatteryBad, ups16AlarmOnBattery,
|
|
ups16AlarmLowBattery, ups16AlarmDepletedBattery,
|
|
ups16AlarmTempBad, ups16AlarmInputBad, ups16AlarmOnBypass,
|
|
ups16AlarmBypassBad, ups16AlarmOutputOffAsRequested,
|
|
ups16AlarmUpsOffAsRequested, ups16AlarmUpsOutputOff,
|
|
ups16AlarmUpsSystemOff, ups16AlarmGeneralFault,
|
|
ups16AlarmDiagnosticTestFailed,
|
|
ups16AlarmCommunicationsLost, ups16AlarmShutdownPending,
|
|
and ups16AlarmTestInProgress."
|
|
|
|
OBJECT ups16TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups16TestNoTestsInitiated,
|
|
ups16TestGeneralSystemsTest, and
|
|
ups16TestQuickBatteryTest."
|
|
|
|
OBJECT ups16OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups16FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups16FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups16ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups16Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups16Groups OBJECT IDENTIFIER ::= { ups16Conformance 2 }
|
|
|
|
ups16SubsetGroups OBJECT IDENTIFIER ::= { ups16Groups 1 }
|
|
|
|
ups16SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups16IdentManufacturer, ups16IdentModel,
|
|
ups16IdentAgentSoftwareVersion, ups16IdentName,
|
|
ups16IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups16SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups16SubsetGroups 1 }
|
|
|
|
ups16SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups16BatteryStatus, ups16SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups16SubsetGroups 2 }
|
|
|
|
ups16SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups16InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups16SubsetGroups 3 }
|
|
|
|
ups16SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups16OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups16SubsetGroups 4 }
|
|
|
|
|
|
-- { ups16SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups16SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups16AlarmsPresent, ups16AlarmDescr, ups16AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups16SubsetGroups 6 }
|
|
|
|
-- { ups16SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups16SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups16ShutdownType, ups16ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups16SubsetGroups 8 }
|
|
|
|
ups16BasicGroups OBJECT IDENTIFIER ::= { ups16Groups 2 }
|
|
|
|
ups16BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups16IdentManufacturer, ups16IdentModel,
|
|
ups16IdentUPSSoftwareVersion,
|
|
ups16IdentAgentSoftwareVersion, ups16IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 1 }
|
|
|
|
ups16BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups16BatteryStatus, ups16SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 2 }
|
|
|
|
ups16BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups16InputLineBads, ups16InputNumLines,
|
|
ups16InputFrequency, ups16InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 3 }
|
|
|
|
ups16BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups16OutputSource, ups16OutputFrequency,
|
|
ups16OutputNumLines, ups16OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 4 }
|
|
|
|
ups16BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups16BypassFrequency, ups16BypassNumLines,
|
|
ups16BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 5 }
|
|
|
|
ups16BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups16AlarmsPresent, ups16AlarmDescr, ups16AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups16BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 6 }
|
|
|
|
ups16BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups16TestId, ups16TestSpinLock,
|
|
ups16TestResultsSummary, ups16TestResultsDetail,
|
|
ups16TestStartTime, ups16TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 7 }
|
|
|
|
ups16BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups16ShutdownType, ups16ShutdownAfterDelay,
|
|
ups16StartupAfterDelay, ups16RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups16BasicGroups 8 }
|
|
|
|
ups16FullGroups OBJECT IDENTIFIER ::= { ups16Groups 3 }
|
|
|
|
ups16FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups16IdentManufacturer, ups16IdentModel,
|
|
ups16IdentUPSSoftwareVersion,
|
|
ups16IdentAgentSoftwareVersion, ups16IdentName,
|
|
ups16IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups16FullGroups 1 }
|
|
|
|
ups16FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups16BatteryStatus, ups16SecondsOnBattery,
|
|
ups16EstimatedMinutesRemaining,
|
|
ups16EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 2 }
|
|
|
|
ups16FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups16InputLineBads, ups16InputNumLines,
|
|
ups16InputFrequency, ups16InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 3 }
|
|
|
|
ups16FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups16OutputSource, ups16OutputFrequency,
|
|
ups16OutputNumLines, ups16OutputVoltage,
|
|
ups16OutputCurrent, ups16OutputPower,
|
|
ups16OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 4 }
|
|
|
|
ups16FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups16BypassFrequency, ups16BypassNumLines,
|
|
ups16BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 5 }
|
|
|
|
ups16FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups16AlarmsPresent, ups16AlarmDescr, ups16AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups16FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 6 }
|
|
|
|
ups16FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups16TestId, ups16TestSpinLock,
|
|
ups16TestResultsSummary, ups16TestResultsDetail,
|
|
ups16TestStartTime, ups16TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 7 }
|
|
|
|
ups16FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups16ShutdownType, ups16ShutdownAfterDelay,
|
|
ups16StartupAfterDelay, ups16RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups16FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups16FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 17 data
|
|
--
|
|
|
|
upsModule17 OBJECT IDENTIFIER ::= { upsModular 18 }
|
|
ups17Objects OBJECT IDENTIFIER ::= { upsModule17 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups17IdentName and
|
|
-- ups17IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups17Ident OBJECT IDENTIFIER ::= { ups17Objects 1 }
|
|
|
|
ups17IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups17Ident 1 }
|
|
|
|
ups17IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups17Ident 2 }
|
|
|
|
ups17IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups17IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups17Ident 3 }
|
|
|
|
ups17IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups17IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups17Ident 4 }
|
|
|
|
ups17IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups17Ident 5 }
|
|
|
|
ups17IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups17Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups17Battery OBJECT IDENTIFIER ::= { ups17Objects 2 }
|
|
|
|
ups17BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups17ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups17ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups17Battery 1 }
|
|
|
|
ups17SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups17Battery 2 }
|
|
|
|
ups17EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups17Battery 3 }
|
|
|
|
ups17EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups17Battery 4 }
|
|
|
|
ups17BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups17Battery 5 }
|
|
|
|
ups17BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups17Battery 6 }
|
|
|
|
ups17BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups17Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups17Input OBJECT IDENTIFIER ::= { ups17Objects 3 }
|
|
|
|
ups17InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups17Input 1 }
|
|
|
|
|
|
ups17InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups17Input 2 }
|
|
|
|
ups17InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups17InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups17InputNumLines."
|
|
::= { ups17Input 3 }
|
|
|
|
ups17InputEntry OBJECT-TYPE
|
|
SYNTAX Ups17InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups17InputLineIndex }
|
|
::= { ups17InputTable 1 }
|
|
|
|
Ups17InputEntry ::= SEQUENCE {
|
|
ups17InputLineIndex PositiveInteger,
|
|
ups17InputFrequency NonNegativeInteger,
|
|
ups17InputVoltage NonNegativeInteger,
|
|
ups17InputCurrent NonNegativeInteger,
|
|
ups17InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups17InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups17InputEntry 1 }
|
|
|
|
ups17InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups17InputEntry 2 }
|
|
|
|
ups17InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups17InputEntry 3 }
|
|
|
|
ups17InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups17InputEntry 4 }
|
|
|
|
ups17InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups17InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups17Output OBJECT IDENTIFIER ::= { ups17Objects 4 }
|
|
|
|
ups17OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups17Output 1 }
|
|
|
|
ups17OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups17Output 2 }
|
|
|
|
ups17OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups17Output 3 }
|
|
|
|
ups17OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups17OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups17OutputNumLines."
|
|
::= { ups17Output 4 }
|
|
|
|
ups17OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups17OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups17OutputLineIndex }
|
|
::= { ups17OutputTable 1 }
|
|
|
|
Ups17OutputEntry ::= SEQUENCE {
|
|
ups17OutputLineIndex PositiveInteger,
|
|
ups17OutputVoltage NonNegativeInteger,
|
|
ups17OutputCurrent NonNegativeInteger,
|
|
ups17OutputPower NonNegativeInteger,
|
|
ups17OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups17OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups17OutputEntry 1 }
|
|
|
|
ups17OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups17OutputEntry 2 }
|
|
|
|
ups17OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups17OutputEntry 3 }
|
|
|
|
ups17OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups17OutputEntry 4 }
|
|
|
|
ups17OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups17OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups17Bypass OBJECT IDENTIFIER ::= { ups17Objects 5 }
|
|
|
|
ups17BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups17Bypass 1 }
|
|
|
|
ups17BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups17Bypass 2 }
|
|
|
|
ups17BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups17BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups17BypassNumLines."
|
|
::= { ups17Bypass 3 }
|
|
|
|
ups17BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups17BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups17BypassLineIndex }
|
|
::= { ups17BypassTable 1 }
|
|
|
|
Ups17BypassEntry ::= SEQUENCE {
|
|
ups17BypassLineIndex PositiveInteger,
|
|
ups17BypassVoltage NonNegativeInteger,
|
|
ups17BypassCurrent NonNegativeInteger,
|
|
ups17BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups17BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups17BypassEntry 1 }
|
|
|
|
ups17BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups17BypassEntry 2 }
|
|
|
|
ups17BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups17BypassEntry 3 }
|
|
|
|
ups17BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups17BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups17Alarm OBJECT IDENTIFIER ::= { ups17Objects 6 }
|
|
|
|
ups17AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups17Alarm 1 }
|
|
|
|
ups17AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups17AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups17AlarmId equal to 1, and increments the value of
|
|
ups17AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups17AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups17AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups17AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups17AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups17AlarmsPresent."
|
|
::= { ups17Alarm 2 }
|
|
|
|
ups17AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups17AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups17AlarmId }
|
|
::= { ups17AlarmTable 1 }
|
|
|
|
Ups17AlarmEntry ::= SEQUENCE {
|
|
ups17AlarmId PositiveInteger,
|
|
ups17AlarmDescr AutonomousType,
|
|
ups17AlarmTime TimeStamp
|
|
}
|
|
|
|
ups17AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups17AlarmEntry 1 }
|
|
|
|
ups17AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups17AlarmEntry 2 }
|
|
|
|
ups17AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups17AlarmTime shall equal
|
|
0."
|
|
::= { ups17AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups17WellKnownAlarms OBJECT IDENTIFIER ::= { ups17Alarm 3 }
|
|
ups17AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups17WellKnownAlarms 1 }
|
|
|
|
ups17AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups17WellKnownAlarms 2 }
|
|
|
|
ups17AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups17ConfigLowBattTime."
|
|
::= { ups17WellKnownAlarms 3 }
|
|
|
|
|
|
ups17AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups17WellKnownAlarms 4 }
|
|
|
|
ups17AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups17WellKnownAlarms 5 }
|
|
|
|
ups17AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups17WellKnownAlarms 6 }
|
|
|
|
ups17AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups17WellKnownAlarms 7 }
|
|
|
|
ups17AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups17WellKnownAlarms 8 }
|
|
|
|
ups17AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups17WellKnownAlarms 9 }
|
|
|
|
ups17AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups17WellKnownAlarms 10 }
|
|
|
|
ups17AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups17WellKnownAlarms 11 }
|
|
|
|
ups17AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups17WellKnownAlarms 12 }
|
|
|
|
ups17AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups17WellKnownAlarms 13 }
|
|
|
|
ups17AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups17WellKnownAlarms 14 }
|
|
|
|
ups17AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups17WellKnownAlarms 15 }
|
|
|
|
ups17AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups17WellKnownAlarms 16 }
|
|
|
|
ups17AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups17WellKnownAlarms 17 }
|
|
|
|
ups17AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups17WellKnownAlarms 18 }
|
|
|
|
ups17AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups17WellKnownAlarms 19 }
|
|
|
|
ups17AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups17WellKnownAlarms 20 }
|
|
|
|
ups17AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups17WellKnownAlarms 21 }
|
|
|
|
ups17AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups17ShutdownAfterDelay countdown is underway."
|
|
::= { ups17WellKnownAlarms 22 }
|
|
|
|
ups17AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups17WellKnownAlarms 23 }
|
|
|
|
ups17AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups17WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups17Test OBJECT IDENTIFIER ::= { ups17Objects 7 }
|
|
|
|
ups17TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups17TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups17TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups17TestId variable to
|
|
ups17TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups17TestNoTestsInitiated is returned."
|
|
::= { ups17Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups17TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups17TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups17TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups17TestResultsSummary */
|
|
get (upsTestSpinLock, ups17TestResultsSummary,
|
|
ups17TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups17TestResultsSummary,
|
|
ups17TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups17TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups17TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups17Test 2 }
|
|
|
|
ups17TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups17TestId to ups17TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups17Test 3 }
|
|
|
|
ups17TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups17TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups17Test 4 }
|
|
|
|
ups17TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups17TestResultsSummary is noTestsInitiated(6),
|
|
ups17TestStartTime has the value 0."
|
|
::= { ups17Test 5 }
|
|
|
|
ups17TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups17TestResultsSummary is noTestsInitiated(6),
|
|
ups17TestElapsedTime has the value 0."
|
|
::= { ups17Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups17WellKnownTests OBJECT IDENTIFIER ::= { ups17Test 7 }
|
|
|
|
|
|
ups17TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups17WellKnownTests 1 }
|
|
|
|
ups17TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups17WellKnownTests 2 }
|
|
|
|
ups17TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups17WellKnownTests 3 }
|
|
|
|
ups17TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups17WellKnownTests 4 }
|
|
|
|
ups17TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups17WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups17Control OBJECT IDENTIFIER ::= { ups17Objects 8 }
|
|
|
|
ups17ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups17ShutdownAfterDelay and ups17RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups17Control 1 }
|
|
|
|
ups17ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups17ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups17ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups17ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups17ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups17ShutdownAfterDelay already in effect."
|
|
::= { ups17Control 2 }
|
|
|
|
ups17StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups17StartupAfterDelay
|
|
countdown or ups17RebootWithDuration countdown in
|
|
progress. When read, ups17StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups17Control 3 }
|
|
|
|
ups17RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups17ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups17RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups17Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups17Traps OBJECT IDENTIFIER ::= { upsModule17 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups17TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups17EstimatedMinutesRemaining, ups17SecondsOnBattery,
|
|
ups17ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups17Traps 1 }
|
|
|
|
ups17TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups17TestId, ups17TestSpinLock,
|
|
ups17TestResultsSummary, ups17TestResultsDetail,
|
|
ups17TestStartTime, ups17TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups17Traps 2 }
|
|
|
|
ups17TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups17AlarmId, ups17AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups17AlarmOnBattery and
|
|
ups17AlarmTestInProgress."
|
|
::= { ups17Traps 3 }
|
|
|
|
ups17TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups17AlarmId, ups17AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups17AlarmTestInProgress."
|
|
::= { ups17Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups17Conformance OBJECT IDENTIFIER ::= { upsModule17 3 }
|
|
|
|
ups17Compliances OBJECT IDENTIFIER ::= { ups17Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups17SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups17SubsetIdentGroup,
|
|
ups17SubsetBatteryGroup, ups17SubsetInputGroup,
|
|
ups17SubsetOutputGroup, ups17SubsetAlarmGroup,
|
|
ups17SubsetControlGroup }
|
|
|
|
OBJECT ups17BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups17AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups17AlarmOnBattery, ups17AlarmLowBattery,
|
|
ups17AlarmInputBad, ups17AlarmUpsOutputOff,
|
|
ups17AlarmUpsSystemOff, and ups17AlarmTestInProgress."
|
|
|
|
OBJECT ups17OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups17ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups17Compliances 1 }
|
|
|
|
ups17BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups17BasicIdentGroup,
|
|
ups17BasicBatteryGroup, ups17BasicInputGroup,
|
|
ups17BasicOutputGroup, ups17BasicAlarmGroup,
|
|
ups17BasicTestGroup, ups17BasicControlGroup }
|
|
|
|
OBJECT ups17AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups17AlarmOnBattery, ups17AlarmLowBattery,
|
|
ups17AlarmDepletedBattery, ups17AlarmTempBad,
|
|
ups17AlarmInputBad, ups17AlarmOutputOverload,
|
|
ups17AlarmOnBypass, ups17AlarmBypassBad,
|
|
ups17AlarmOutputOffAsRequested,
|
|
ups17AlarmUpsOffAsRequested, ups17AlarmUpsOutputOff,
|
|
ups17AlarmUpsSystemOff, ups17AlarmGeneralFault,
|
|
ups17AlarmDiagnosticTestFailed,
|
|
ups17AlarmCommunicationsLost, ups17AlarmShutdownPending,
|
|
and ups17AlarmTestInProgress."
|
|
|
|
OBJECT ups17TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups17TestNoTestsInitiated."
|
|
|
|
OBJECT ups17OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups17BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups17BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups17ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups17Compliances 2 }
|
|
|
|
ups17FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups17FullIdentGroup, ups17FullBatteryGroup,
|
|
ups17FullInputGroup, ups17FullOutputGroup,
|
|
ups17FullAlarmGroup, ups17FullTestGroup,
|
|
ups17FullControlGroup }
|
|
|
|
OBJECT ups17AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups17AlarmBatteryBad, ups17AlarmOnBattery,
|
|
ups17AlarmLowBattery, ups17AlarmDepletedBattery,
|
|
ups17AlarmTempBad, ups17AlarmInputBad, ups17AlarmOnBypass,
|
|
ups17AlarmBypassBad, ups17AlarmOutputOffAsRequested,
|
|
ups17AlarmUpsOffAsRequested, ups17AlarmUpsOutputOff,
|
|
ups17AlarmUpsSystemOff, ups17AlarmGeneralFault,
|
|
ups17AlarmDiagnosticTestFailed,
|
|
ups17AlarmCommunicationsLost, ups17AlarmShutdownPending,
|
|
and ups17AlarmTestInProgress."
|
|
|
|
OBJECT ups17TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups17TestNoTestsInitiated,
|
|
ups17TestGeneralSystemsTest, and
|
|
ups17TestQuickBatteryTest."
|
|
|
|
OBJECT ups17OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups17FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups17FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups17ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups17Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups17Groups OBJECT IDENTIFIER ::= { ups17Conformance 2 }
|
|
|
|
ups17SubsetGroups OBJECT IDENTIFIER ::= { ups17Groups 1 }
|
|
|
|
ups17SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups17IdentManufacturer, ups17IdentModel,
|
|
ups17IdentAgentSoftwareVersion, ups17IdentName,
|
|
ups17IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups17SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups17SubsetGroups 1 }
|
|
|
|
ups17SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups17BatteryStatus, ups17SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups17SubsetGroups 2 }
|
|
|
|
ups17SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups17InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups17SubsetGroups 3 }
|
|
|
|
ups17SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups17OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups17SubsetGroups 4 }
|
|
|
|
|
|
-- { ups17SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups17SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups17AlarmsPresent, ups17AlarmDescr, ups17AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups17SubsetGroups 6 }
|
|
|
|
-- { ups17SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups17SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups17ShutdownType, ups17ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups17SubsetGroups 8 }
|
|
|
|
ups17BasicGroups OBJECT IDENTIFIER ::= { ups17Groups 2 }
|
|
|
|
ups17BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups17IdentManufacturer, ups17IdentModel,
|
|
ups17IdentUPSSoftwareVersion,
|
|
ups17IdentAgentSoftwareVersion, ups17IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 1 }
|
|
|
|
ups17BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups17BatteryStatus, ups17SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 2 }
|
|
|
|
ups17BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups17InputLineBads, ups17InputNumLines,
|
|
ups17InputFrequency, ups17InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 3 }
|
|
|
|
ups17BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups17OutputSource, ups17OutputFrequency,
|
|
ups17OutputNumLines, ups17OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 4 }
|
|
|
|
ups17BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups17BypassFrequency, ups17BypassNumLines,
|
|
ups17BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 5 }
|
|
|
|
ups17BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups17AlarmsPresent, ups17AlarmDescr, ups17AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups17BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 6 }
|
|
|
|
ups17BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups17TestId, ups17TestSpinLock,
|
|
ups17TestResultsSummary, ups17TestResultsDetail,
|
|
ups17TestStartTime, ups17TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 7 }
|
|
|
|
ups17BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups17ShutdownType, ups17ShutdownAfterDelay,
|
|
ups17StartupAfterDelay, ups17RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups17BasicGroups 8 }
|
|
|
|
ups17FullGroups OBJECT IDENTIFIER ::= { ups17Groups 3 }
|
|
|
|
ups17FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups17IdentManufacturer, ups17IdentModel,
|
|
ups17IdentUPSSoftwareVersion,
|
|
ups17IdentAgentSoftwareVersion, ups17IdentName,
|
|
ups17IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups17FullGroups 1 }
|
|
|
|
ups17FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups17BatteryStatus, ups17SecondsOnBattery,
|
|
ups17EstimatedMinutesRemaining,
|
|
ups17EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 2 }
|
|
|
|
ups17FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups17InputLineBads, ups17InputNumLines,
|
|
ups17InputFrequency, ups17InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 3 }
|
|
|
|
ups17FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups17OutputSource, ups17OutputFrequency,
|
|
ups17OutputNumLines, ups17OutputVoltage,
|
|
ups17OutputCurrent, ups17OutputPower,
|
|
ups17OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 4 }
|
|
|
|
ups17FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups17BypassFrequency, ups17BypassNumLines,
|
|
ups17BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 5 }
|
|
|
|
ups17FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups17AlarmsPresent, ups17AlarmDescr, ups17AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups17FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 6 }
|
|
|
|
ups17FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups17TestId, ups17TestSpinLock,
|
|
ups17TestResultsSummary, ups17TestResultsDetail,
|
|
ups17TestStartTime, ups17TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 7 }
|
|
|
|
ups17FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups17ShutdownType, ups17ShutdownAfterDelay,
|
|
ups17StartupAfterDelay, ups17RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups17FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups17FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 18 data
|
|
--
|
|
|
|
upsModule18 OBJECT IDENTIFIER ::= { upsModular 19 }
|
|
ups18Objects OBJECT IDENTIFIER ::= { upsModule18 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups18IdentName and
|
|
-- ups18IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups18Ident OBJECT IDENTIFIER ::= { ups18Objects 1 }
|
|
|
|
ups18IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups18Ident 1 }
|
|
|
|
ups18IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups18Ident 2 }
|
|
|
|
ups18IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups18IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups18Ident 3 }
|
|
|
|
ups18IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups18IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups18Ident 4 }
|
|
|
|
ups18IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups18Ident 5 }
|
|
|
|
ups18IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups18Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups18Battery OBJECT IDENTIFIER ::= { ups18Objects 2 }
|
|
|
|
ups18BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups18ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups18ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups18Battery 1 }
|
|
|
|
ups18SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups18Battery 2 }
|
|
|
|
ups18EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups18Battery 3 }
|
|
|
|
ups18EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups18Battery 4 }
|
|
|
|
ups18BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups18Battery 5 }
|
|
|
|
ups18BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups18Battery 6 }
|
|
|
|
ups18BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups18Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups18Input OBJECT IDENTIFIER ::= { ups18Objects 3 }
|
|
|
|
ups18InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups18Input 1 }
|
|
|
|
|
|
ups18InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups18Input 2 }
|
|
|
|
ups18InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups18InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups18InputNumLines."
|
|
::= { ups18Input 3 }
|
|
|
|
ups18InputEntry OBJECT-TYPE
|
|
SYNTAX Ups18InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups18InputLineIndex }
|
|
::= { ups18InputTable 1 }
|
|
|
|
Ups18InputEntry ::= SEQUENCE {
|
|
ups18InputLineIndex PositiveInteger,
|
|
ups18InputFrequency NonNegativeInteger,
|
|
ups18InputVoltage NonNegativeInteger,
|
|
ups18InputCurrent NonNegativeInteger,
|
|
ups18InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups18InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups18InputEntry 1 }
|
|
|
|
ups18InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups18InputEntry 2 }
|
|
|
|
ups18InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups18InputEntry 3 }
|
|
|
|
ups18InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups18InputEntry 4 }
|
|
|
|
ups18InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups18InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups18Output OBJECT IDENTIFIER ::= { ups18Objects 4 }
|
|
|
|
ups18OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups18Output 1 }
|
|
|
|
ups18OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups18Output 2 }
|
|
|
|
ups18OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups18Output 3 }
|
|
|
|
ups18OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups18OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups18OutputNumLines."
|
|
::= { ups18Output 4 }
|
|
|
|
ups18OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups18OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups18OutputLineIndex }
|
|
::= { ups18OutputTable 1 }
|
|
|
|
Ups18OutputEntry ::= SEQUENCE {
|
|
ups18OutputLineIndex PositiveInteger,
|
|
ups18OutputVoltage NonNegativeInteger,
|
|
ups18OutputCurrent NonNegativeInteger,
|
|
ups18OutputPower NonNegativeInteger,
|
|
ups18OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups18OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups18OutputEntry 1 }
|
|
|
|
ups18OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups18OutputEntry 2 }
|
|
|
|
ups18OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups18OutputEntry 3 }
|
|
|
|
ups18OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups18OutputEntry 4 }
|
|
|
|
ups18OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups18OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups18Bypass OBJECT IDENTIFIER ::= { ups18Objects 5 }
|
|
|
|
ups18BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups18Bypass 1 }
|
|
|
|
ups18BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups18Bypass 2 }
|
|
|
|
ups18BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups18BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups18BypassNumLines."
|
|
::= { ups18Bypass 3 }
|
|
|
|
ups18BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups18BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups18BypassLineIndex }
|
|
::= { ups18BypassTable 1 }
|
|
|
|
Ups18BypassEntry ::= SEQUENCE {
|
|
ups18BypassLineIndex PositiveInteger,
|
|
ups18BypassVoltage NonNegativeInteger,
|
|
ups18BypassCurrent NonNegativeInteger,
|
|
ups18BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups18BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups18BypassEntry 1 }
|
|
|
|
ups18BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups18BypassEntry 2 }
|
|
|
|
ups18BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups18BypassEntry 3 }
|
|
|
|
ups18BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups18BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups18Alarm OBJECT IDENTIFIER ::= { ups18Objects 6 }
|
|
|
|
ups18AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups18Alarm 1 }
|
|
|
|
ups18AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups18AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups18AlarmId equal to 1, and increments the value of
|
|
ups18AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups18AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups18AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups18AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups18AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups18AlarmsPresent."
|
|
::= { ups18Alarm 2 }
|
|
|
|
ups18AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups18AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups18AlarmId }
|
|
::= { ups18AlarmTable 1 }
|
|
|
|
Ups18AlarmEntry ::= SEQUENCE {
|
|
ups18AlarmId PositiveInteger,
|
|
ups18AlarmDescr AutonomousType,
|
|
ups18AlarmTime TimeStamp
|
|
}
|
|
|
|
ups18AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups18AlarmEntry 1 }
|
|
|
|
ups18AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups18AlarmEntry 2 }
|
|
|
|
ups18AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups18AlarmTime shall equal
|
|
0."
|
|
::= { ups18AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups18WellKnownAlarms OBJECT IDENTIFIER ::= { ups18Alarm 3 }
|
|
ups18AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups18WellKnownAlarms 1 }
|
|
|
|
ups18AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups18WellKnownAlarms 2 }
|
|
|
|
ups18AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups18ConfigLowBattTime."
|
|
::= { ups18WellKnownAlarms 3 }
|
|
|
|
|
|
ups18AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups18WellKnownAlarms 4 }
|
|
|
|
ups18AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups18WellKnownAlarms 5 }
|
|
|
|
ups18AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups18WellKnownAlarms 6 }
|
|
|
|
ups18AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups18WellKnownAlarms 7 }
|
|
|
|
ups18AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups18WellKnownAlarms 8 }
|
|
|
|
ups18AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups18WellKnownAlarms 9 }
|
|
|
|
ups18AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups18WellKnownAlarms 10 }
|
|
|
|
ups18AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups18WellKnownAlarms 11 }
|
|
|
|
ups18AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups18WellKnownAlarms 12 }
|
|
|
|
ups18AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups18WellKnownAlarms 13 }
|
|
|
|
ups18AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups18WellKnownAlarms 14 }
|
|
|
|
ups18AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups18WellKnownAlarms 15 }
|
|
|
|
ups18AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups18WellKnownAlarms 16 }
|
|
|
|
ups18AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups18WellKnownAlarms 17 }
|
|
|
|
ups18AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups18WellKnownAlarms 18 }
|
|
|
|
ups18AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups18WellKnownAlarms 19 }
|
|
|
|
ups18AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups18WellKnownAlarms 20 }
|
|
|
|
ups18AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups18WellKnownAlarms 21 }
|
|
|
|
ups18AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups18ShutdownAfterDelay countdown is underway."
|
|
::= { ups18WellKnownAlarms 22 }
|
|
|
|
ups18AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups18WellKnownAlarms 23 }
|
|
|
|
ups18AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups18WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups18Test OBJECT IDENTIFIER ::= { ups18Objects 7 }
|
|
|
|
ups18TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups18TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups18TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups18TestId variable to
|
|
ups18TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups18TestNoTestsInitiated is returned."
|
|
::= { ups18Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups18TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups18TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups18TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups18TestResultsSummary */
|
|
get (upsTestSpinLock, ups18TestResultsSummary,
|
|
ups18TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups18TestResultsSummary,
|
|
ups18TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups18TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups18TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups18Test 2 }
|
|
|
|
ups18TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups18TestId to ups18TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups18Test 3 }
|
|
|
|
ups18TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups18TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups18Test 4 }
|
|
|
|
ups18TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups18TestResultsSummary is noTestsInitiated(6),
|
|
ups18TestStartTime has the value 0."
|
|
::= { ups18Test 5 }
|
|
|
|
ups18TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups18TestResultsSummary is noTestsInitiated(6),
|
|
ups18TestElapsedTime has the value 0."
|
|
::= { ups18Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups18WellKnownTests OBJECT IDENTIFIER ::= { ups18Test 7 }
|
|
|
|
|
|
ups18TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups18WellKnownTests 1 }
|
|
|
|
ups18TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups18WellKnownTests 2 }
|
|
|
|
ups18TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups18WellKnownTests 3 }
|
|
|
|
ups18TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups18WellKnownTests 4 }
|
|
|
|
ups18TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups18WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups18Control OBJECT IDENTIFIER ::= { ups18Objects 8 }
|
|
|
|
ups18ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups18ShutdownAfterDelay and ups18RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups18Control 1 }
|
|
|
|
ups18ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups18ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups18ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups18ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups18ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups18ShutdownAfterDelay already in effect."
|
|
::= { ups18Control 2 }
|
|
|
|
ups18StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups18StartupAfterDelay
|
|
countdown or ups18RebootWithDuration countdown in
|
|
progress. When read, ups18StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups18Control 3 }
|
|
|
|
ups18RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups18ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups18RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups18Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups18Traps OBJECT IDENTIFIER ::= { upsModule18 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups18TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups18EstimatedMinutesRemaining, ups18SecondsOnBattery,
|
|
ups18ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups18Traps 1 }
|
|
|
|
ups18TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups18TestId, ups18TestSpinLock,
|
|
ups18TestResultsSummary, ups18TestResultsDetail,
|
|
ups18TestStartTime, ups18TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups18Traps 2 }
|
|
|
|
ups18TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups18AlarmId, ups18AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups18AlarmOnBattery and
|
|
ups18AlarmTestInProgress."
|
|
::= { ups18Traps 3 }
|
|
|
|
ups18TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups18AlarmId, ups18AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups18AlarmTestInProgress."
|
|
::= { ups18Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups18Conformance OBJECT IDENTIFIER ::= { upsModule18 3 }
|
|
|
|
ups18Compliances OBJECT IDENTIFIER ::= { ups18Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups18SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups18SubsetIdentGroup,
|
|
ups18SubsetBatteryGroup, ups18SubsetInputGroup,
|
|
ups18SubsetOutputGroup, ups18SubsetAlarmGroup,
|
|
ups18SubsetControlGroup }
|
|
|
|
OBJECT ups18BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups18AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups18AlarmOnBattery, ups18AlarmLowBattery,
|
|
ups18AlarmInputBad, ups18AlarmUpsOutputOff,
|
|
ups18AlarmUpsSystemOff, and ups18AlarmTestInProgress."
|
|
|
|
OBJECT ups18OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups18ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups18Compliances 1 }
|
|
|
|
ups18BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups18BasicIdentGroup,
|
|
ups18BasicBatteryGroup, ups18BasicInputGroup,
|
|
ups18BasicOutputGroup, ups18BasicAlarmGroup,
|
|
ups18BasicTestGroup, ups18BasicControlGroup }
|
|
|
|
|
|
OBJECT ups18AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups18AlarmOnBattery, ups18AlarmLowBattery,
|
|
ups18AlarmDepletedBattery, ups18AlarmTempBad,
|
|
ups18AlarmInputBad, ups18AlarmOutputOverload,
|
|
ups18AlarmOnBypass, ups18AlarmBypassBad,
|
|
ups18AlarmOutputOffAsRequested,
|
|
ups18AlarmUpsOffAsRequested, ups18AlarmUpsOutputOff,
|
|
ups18AlarmUpsSystemOff, ups18AlarmGeneralFault,
|
|
ups18AlarmDiagnosticTestFailed,
|
|
ups18AlarmCommunicationsLost, ups18AlarmShutdownPending,
|
|
and ups18AlarmTestInProgress."
|
|
|
|
OBJECT ups18TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups18TestNoTestsInitiated."
|
|
|
|
OBJECT ups18OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups18BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups18BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups18ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups18Compliances 2 }
|
|
|
|
ups18FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups18FullIdentGroup, ups18FullBatteryGroup,
|
|
ups18FullInputGroup, ups18FullOutputGroup,
|
|
ups18FullAlarmGroup, ups18FullTestGroup,
|
|
ups18FullControlGroup }
|
|
|
|
OBJECT ups18AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups18AlarmBatteryBad, ups18AlarmOnBattery,
|
|
ups18AlarmLowBattery, ups18AlarmDepletedBattery,
|
|
ups18AlarmTempBad, ups18AlarmInputBad, ups18AlarmOnBypass,
|
|
ups18AlarmBypassBad, ups18AlarmOutputOffAsRequested,
|
|
ups18AlarmUpsOffAsRequested, ups18AlarmUpsOutputOff,
|
|
ups18AlarmUpsSystemOff, ups18AlarmGeneralFault,
|
|
ups18AlarmDiagnosticTestFailed,
|
|
ups18AlarmCommunicationsLost, ups18AlarmShutdownPending,
|
|
and ups18AlarmTestInProgress."
|
|
|
|
OBJECT ups18TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups18TestNoTestsInitiated,
|
|
ups18TestGeneralSystemsTest, and
|
|
ups18TestQuickBatteryTest."
|
|
|
|
OBJECT ups18OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups18FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups18FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups18ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups18Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups18Groups OBJECT IDENTIFIER ::= { ups18Conformance 2 }
|
|
|
|
ups18SubsetGroups OBJECT IDENTIFIER ::= { ups18Groups 1 }
|
|
|
|
ups18SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups18IdentManufacturer, ups18IdentModel,
|
|
ups18IdentAgentSoftwareVersion, ups18IdentName,
|
|
ups18IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups18SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups18SubsetGroups 1 }
|
|
|
|
ups18SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups18BatteryStatus, ups18SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups18SubsetGroups 2 }
|
|
|
|
ups18SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups18InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups18SubsetGroups 3 }
|
|
|
|
ups18SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups18OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups18SubsetGroups 4 }
|
|
|
|
|
|
-- { ups18SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups18SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups18AlarmsPresent, ups18AlarmDescr, ups18AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups18SubsetGroups 6 }
|
|
|
|
-- { ups18SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups18SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups18ShutdownType, ups18ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups18SubsetGroups 8 }
|
|
|
|
ups18BasicGroups OBJECT IDENTIFIER ::= { ups18Groups 2 }
|
|
|
|
ups18BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups18IdentManufacturer, ups18IdentModel,
|
|
ups18IdentUPSSoftwareVersion,
|
|
ups18IdentAgentSoftwareVersion, ups18IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 1 }
|
|
|
|
ups18BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups18BatteryStatus, ups18SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 2 }
|
|
|
|
ups18BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups18InputLineBads, ups18InputNumLines,
|
|
ups18InputFrequency, ups18InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 3 }
|
|
|
|
ups18BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups18OutputSource, ups18OutputFrequency,
|
|
ups18OutputNumLines, ups18OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 4 }
|
|
|
|
ups18BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups18BypassFrequency, ups18BypassNumLines,
|
|
ups18BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 5 }
|
|
|
|
ups18BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups18AlarmsPresent, ups18AlarmDescr, ups18AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups18BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 6 }
|
|
|
|
ups18BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups18TestId, ups18TestSpinLock,
|
|
ups18TestResultsSummary, ups18TestResultsDetail,
|
|
ups18TestStartTime, ups18TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 7 }
|
|
|
|
ups18BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups18ShutdownType, ups18ShutdownAfterDelay,
|
|
ups18StartupAfterDelay, ups18RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups18BasicGroups 8 }
|
|
|
|
ups18FullGroups OBJECT IDENTIFIER ::= { ups18Groups 3 }
|
|
|
|
ups18FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups18IdentManufacturer, ups18IdentModel,
|
|
ups18IdentUPSSoftwareVersion,
|
|
ups18IdentAgentSoftwareVersion, ups18IdentName,
|
|
ups18IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups18FullGroups 1 }
|
|
|
|
ups18FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups18BatteryStatus, ups18SecondsOnBattery,
|
|
ups18EstimatedMinutesRemaining,
|
|
ups18EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 2 }
|
|
|
|
ups18FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups18InputLineBads, ups18InputNumLines,
|
|
ups18InputFrequency, ups18InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 3 }
|
|
|
|
ups18FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups18OutputSource, ups18OutputFrequency,
|
|
ups18OutputNumLines, ups18OutputVoltage,
|
|
ups18OutputCurrent, ups18OutputPower,
|
|
ups18OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 4 }
|
|
|
|
ups18FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups18BypassFrequency, ups18BypassNumLines,
|
|
ups18BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 5 }
|
|
|
|
ups18FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups18AlarmsPresent, ups18AlarmDescr, ups18AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups18FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 6 }
|
|
|
|
ups18FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups18TestId, ups18TestSpinLock,
|
|
ups18TestResultsSummary, ups18TestResultsDetail,
|
|
ups18TestStartTime, ups18TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 7 }
|
|
|
|
ups18FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups18ShutdownType, ups18ShutdownAfterDelay,
|
|
ups18StartupAfterDelay, ups18RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups18FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups18FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 19 data
|
|
--
|
|
|
|
upsModule19 OBJECT IDENTIFIER ::= { upsModular 20 }
|
|
ups19Objects OBJECT IDENTIFIER ::= { upsModule19 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups19IdentName and
|
|
-- ups19IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups19Ident OBJECT IDENTIFIER ::= { ups19Objects 1 }
|
|
|
|
ups19IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups19Ident 1 }
|
|
|
|
ups19IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups19Ident 2 }
|
|
|
|
ups19IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups19IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups19Ident 3 }
|
|
|
|
ups19IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups19IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups19Ident 4 }
|
|
|
|
ups19IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups19Ident 5 }
|
|
|
|
ups19IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups19Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups19Battery OBJECT IDENTIFIER ::= { ups19Objects 2 }
|
|
|
|
ups19BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups19ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups19ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups19Battery 1 }
|
|
|
|
ups19SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups19Battery 2 }
|
|
|
|
ups19EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups19Battery 3 }
|
|
|
|
ups19EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups19Battery 4 }
|
|
|
|
ups19BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups19Battery 5 }
|
|
|
|
ups19BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups19Battery 6 }
|
|
|
|
ups19BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups19Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups19Input OBJECT IDENTIFIER ::= { ups19Objects 3 }
|
|
|
|
ups19InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups19Input 1 }
|
|
|
|
|
|
ups19InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups19Input 2 }
|
|
|
|
ups19InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups19InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups19InputNumLines."
|
|
::= { ups19Input 3 }
|
|
|
|
ups19InputEntry OBJECT-TYPE
|
|
SYNTAX Ups19InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups19InputLineIndex }
|
|
::= { ups19InputTable 1 }
|
|
|
|
Ups19InputEntry ::= SEQUENCE {
|
|
ups19InputLineIndex PositiveInteger,
|
|
ups19InputFrequency NonNegativeInteger,
|
|
ups19InputVoltage NonNegativeInteger,
|
|
ups19InputCurrent NonNegativeInteger,
|
|
ups19InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups19InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups19InputEntry 1 }
|
|
|
|
ups19InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups19InputEntry 2 }
|
|
|
|
ups19InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups19InputEntry 3 }
|
|
|
|
ups19InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups19InputEntry 4 }
|
|
|
|
ups19InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups19InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups19Output OBJECT IDENTIFIER ::= { ups19Objects 4 }
|
|
|
|
ups19OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups19Output 1 }
|
|
|
|
ups19OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups19Output 2 }
|
|
|
|
ups19OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups19Output 3 }
|
|
|
|
ups19OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups19OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups19OutputNumLines."
|
|
::= { ups19Output 4 }
|
|
|
|
ups19OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups19OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups19OutputLineIndex }
|
|
::= { ups19OutputTable 1 }
|
|
|
|
Ups19OutputEntry ::= SEQUENCE {
|
|
ups19OutputLineIndex PositiveInteger,
|
|
ups19OutputVoltage NonNegativeInteger,
|
|
ups19OutputCurrent NonNegativeInteger,
|
|
ups19OutputPower NonNegativeInteger,
|
|
ups19OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups19OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups19OutputEntry 1 }
|
|
|
|
ups19OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups19OutputEntry 2 }
|
|
|
|
ups19OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups19OutputEntry 3 }
|
|
|
|
ups19OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups19OutputEntry 4 }
|
|
|
|
ups19OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups19OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups19Bypass OBJECT IDENTIFIER ::= { ups19Objects 5 }
|
|
|
|
ups19BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups19Bypass 1 }
|
|
|
|
ups19BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups19Bypass 2 }
|
|
|
|
ups19BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups19BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups19BypassNumLines."
|
|
::= { ups19Bypass 3 }
|
|
|
|
ups19BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups19BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups19BypassLineIndex }
|
|
::= { ups19BypassTable 1 }
|
|
|
|
Ups19BypassEntry ::= SEQUENCE {
|
|
ups19BypassLineIndex PositiveInteger,
|
|
ups19BypassVoltage NonNegativeInteger,
|
|
ups19BypassCurrent NonNegativeInteger,
|
|
ups19BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups19BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups19BypassEntry 1 }
|
|
|
|
ups19BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups19BypassEntry 2 }
|
|
|
|
ups19BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups19BypassEntry 3 }
|
|
|
|
ups19BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups19BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups19Alarm OBJECT IDENTIFIER ::= { ups19Objects 6 }
|
|
|
|
ups19AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups19Alarm 1 }
|
|
|
|
ups19AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups19AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups19AlarmId equal to 1, and increments the value of
|
|
ups19AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups19AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups19AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups19AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups19AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups19AlarmsPresent."
|
|
::= { ups19Alarm 2 }
|
|
|
|
ups19AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups19AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups19AlarmId }
|
|
::= { ups19AlarmTable 1 }
|
|
|
|
Ups19AlarmEntry ::= SEQUENCE {
|
|
ups19AlarmId PositiveInteger,
|
|
ups19AlarmDescr AutonomousType,
|
|
ups19AlarmTime TimeStamp
|
|
}
|
|
|
|
ups19AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups19AlarmEntry 1 }
|
|
|
|
ups19AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups19AlarmEntry 2 }
|
|
|
|
ups19AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups19AlarmTime shall equal
|
|
0."
|
|
::= { ups19AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups19WellKnownAlarms OBJECT IDENTIFIER ::= { ups19Alarm 3 }
|
|
ups19AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups19WellKnownAlarms 1 }
|
|
|
|
ups19AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups19WellKnownAlarms 2 }
|
|
|
|
ups19AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups19ConfigLowBattTime."
|
|
::= { ups19WellKnownAlarms 3 }
|
|
|
|
|
|
ups19AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups19WellKnownAlarms 4 }
|
|
|
|
ups19AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups19WellKnownAlarms 5 }
|
|
|
|
ups19AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups19WellKnownAlarms 6 }
|
|
|
|
ups19AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups19WellKnownAlarms 7 }
|
|
|
|
ups19AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups19WellKnownAlarms 8 }
|
|
|
|
ups19AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups19WellKnownAlarms 9 }
|
|
|
|
ups19AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups19WellKnownAlarms 10 }
|
|
|
|
ups19AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups19WellKnownAlarms 11 }
|
|
|
|
ups19AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups19WellKnownAlarms 12 }
|
|
|
|
ups19AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups19WellKnownAlarms 13 }
|
|
|
|
ups19AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups19WellKnownAlarms 14 }
|
|
|
|
ups19AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups19WellKnownAlarms 15 }
|
|
|
|
ups19AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups19WellKnownAlarms 16 }
|
|
|
|
ups19AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups19WellKnownAlarms 17 }
|
|
|
|
ups19AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups19WellKnownAlarms 18 }
|
|
|
|
ups19AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups19WellKnownAlarms 19 }
|
|
|
|
ups19AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups19WellKnownAlarms 20 }
|
|
|
|
ups19AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups19WellKnownAlarms 21 }
|
|
|
|
ups19AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups19ShutdownAfterDelay countdown is underway."
|
|
::= { ups19WellKnownAlarms 22 }
|
|
|
|
ups19AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups19WellKnownAlarms 23 }
|
|
|
|
ups19AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups19WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups19Test OBJECT IDENTIFIER ::= { ups19Objects 7 }
|
|
|
|
ups19TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups19TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups19TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups19TestId variable to
|
|
ups19TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups19TestNoTestsInitiated is returned."
|
|
::= { ups19Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups19TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups19TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups19TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups19TestResultsSummary */
|
|
get (upsTestSpinLock, ups19TestResultsSummary,
|
|
ups19TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups19TestResultsSummary,
|
|
ups19TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups19TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups19TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups19Test 2 }
|
|
|
|
ups19TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups19TestId to ups19TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups19Test 3 }
|
|
|
|
ups19TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups19TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups19Test 4 }
|
|
|
|
ups19TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups19TestResultsSummary is noTestsInitiated(6),
|
|
ups19TestStartTime has the value 0."
|
|
::= { ups19Test 5 }
|
|
|
|
ups19TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups19TestResultsSummary is noTestsInitiated(6),
|
|
ups19TestElapsedTime has the value 0."
|
|
::= { ups19Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups19WellKnownTests OBJECT IDENTIFIER ::= { ups19Test 7 }
|
|
|
|
|
|
ups19TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups19WellKnownTests 1 }
|
|
|
|
ups19TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups19WellKnownTests 2 }
|
|
|
|
ups19TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups19WellKnownTests 3 }
|
|
|
|
ups19TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups19WellKnownTests 4 }
|
|
|
|
ups19TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups19WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups19Control OBJECT IDENTIFIER ::= { ups19Objects 8 }
|
|
|
|
ups19ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups19ShutdownAfterDelay and ups19RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups19Control 1 }
|
|
|
|
ups19ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups19ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups19ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups19ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups19ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups19ShutdownAfterDelay already in effect."
|
|
::= { ups19Control 2 }
|
|
|
|
ups19StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups19StartupAfterDelay
|
|
countdown or ups19RebootWithDuration countdown in
|
|
progress. When read, ups19StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups19Control 3 }
|
|
|
|
ups19RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups19ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups19RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups19Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups19Traps OBJECT IDENTIFIER ::= { upsModule19 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups19TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups19EstimatedMinutesRemaining, ups19SecondsOnBattery,
|
|
ups19ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups19Traps 1 }
|
|
|
|
ups19TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups19TestId, ups19TestSpinLock,
|
|
ups19TestResultsSummary, ups19TestResultsDetail,
|
|
ups19TestStartTime, ups19TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups19Traps 2 }
|
|
|
|
ups19TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups19AlarmId, ups19AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups19AlarmOnBattery and
|
|
ups19AlarmTestInProgress."
|
|
::= { ups19Traps 3 }
|
|
|
|
ups19TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups19AlarmId, ups19AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups19AlarmTestInProgress."
|
|
::= { ups19Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups19Conformance OBJECT IDENTIFIER ::= { upsModule19 3 }
|
|
|
|
ups19Compliances OBJECT IDENTIFIER ::= { ups19Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups19SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups19SubsetIdentGroup,
|
|
ups19SubsetBatteryGroup, ups19SubsetInputGroup,
|
|
ups19SubsetOutputGroup, ups19SubsetAlarmGroup,
|
|
ups19SubsetControlGroup }
|
|
|
|
OBJECT ups19BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups19AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups19AlarmOnBattery, ups19AlarmLowBattery,
|
|
ups19AlarmInputBad, ups19AlarmUpsOutputOff,
|
|
ups19AlarmUpsSystemOff, and ups19AlarmTestInProgress."
|
|
|
|
OBJECT ups19OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups19ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups19Compliances 1 }
|
|
|
|
ups19BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups19BasicIdentGroup,
|
|
ups19BasicBatteryGroup, ups19BasicInputGroup,
|
|
ups19BasicOutputGroup, ups19BasicAlarmGroup,
|
|
ups19BasicTestGroup, ups19BasicControlGroup }
|
|
|
|
OBJECT ups19AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups19AlarmOnBattery, ups19AlarmLowBattery,
|
|
ups19AlarmDepletedBattery, ups19AlarmTempBad,
|
|
ups19AlarmInputBad, ups19AlarmOutputOverload,
|
|
ups19AlarmOnBypass, ups19AlarmBypassBad,
|
|
ups19AlarmOutputOffAsRequested,
|
|
ups19AlarmUpsOffAsRequested, ups19AlarmUpsOutputOff,
|
|
ups19AlarmUpsSystemOff, ups19AlarmGeneralFault,
|
|
ups19AlarmDiagnosticTestFailed,
|
|
ups19AlarmCommunicationsLost, ups19AlarmShutdownPending,
|
|
and ups19AlarmTestInProgress."
|
|
|
|
OBJECT ups19TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups19TestNoTestsInitiated."
|
|
|
|
OBJECT ups19OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups19BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups19BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups19ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups19Compliances 2 }
|
|
|
|
ups19FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups19FullIdentGroup, ups19FullBatteryGroup,
|
|
ups19FullInputGroup, ups19FullOutputGroup,
|
|
ups19FullAlarmGroup, ups19FullTestGroup,
|
|
ups19FullControlGroup }
|
|
|
|
OBJECT ups19AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups19AlarmBatteryBad, ups19AlarmOnBattery,
|
|
ups19AlarmLowBattery, ups19AlarmDepletedBattery,
|
|
ups19AlarmTempBad, ups19AlarmInputBad, ups19AlarmOnBypass,
|
|
ups19AlarmBypassBad, ups19AlarmOutputOffAsRequested,
|
|
ups19AlarmUpsOffAsRequested, ups19AlarmUpsOutputOff,
|
|
ups19AlarmUpsSystemOff, ups19AlarmGeneralFault,
|
|
ups19AlarmDiagnosticTestFailed,
|
|
ups19AlarmCommunicationsLost, ups19AlarmShutdownPending,
|
|
and ups19AlarmTestInProgress."
|
|
|
|
OBJECT ups19TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups19TestNoTestsInitiated,
|
|
ups19TestGeneralSystemsTest, and
|
|
ups19TestQuickBatteryTest."
|
|
|
|
OBJECT ups19OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups19FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups19FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups19ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups19Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups19Groups OBJECT IDENTIFIER ::= { ups19Conformance 2 }
|
|
|
|
ups19SubsetGroups OBJECT IDENTIFIER ::= { ups19Groups 1 }
|
|
|
|
ups19SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups19IdentManufacturer, ups19IdentModel,
|
|
ups19IdentAgentSoftwareVersion, ups19IdentName,
|
|
ups19IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups19SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups19SubsetGroups 1 }
|
|
|
|
ups19SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups19BatteryStatus, ups19SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups19SubsetGroups 2 }
|
|
|
|
ups19SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups19InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups19SubsetGroups 3 }
|
|
|
|
ups19SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups19OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups19SubsetGroups 4 }
|
|
|
|
|
|
-- { ups19SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups19SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups19AlarmsPresent, ups19AlarmDescr, ups19AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups19SubsetGroups 6 }
|
|
|
|
-- { ups19SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups19SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups19ShutdownType, ups19ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups19SubsetGroups 8 }
|
|
|
|
ups19BasicGroups OBJECT IDENTIFIER ::= { ups19Groups 2 }
|
|
|
|
ups19BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups19IdentManufacturer, ups19IdentModel,
|
|
ups19IdentUPSSoftwareVersion,
|
|
ups19IdentAgentSoftwareVersion, ups19IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 1 }
|
|
|
|
ups19BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups19BatteryStatus, ups19SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 2 }
|
|
|
|
ups19BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups19InputLineBads, ups19InputNumLines,
|
|
ups19InputFrequency, ups19InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 3 }
|
|
|
|
ups19BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups19OutputSource, ups19OutputFrequency,
|
|
ups19OutputNumLines, ups19OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 4 }
|
|
|
|
ups19BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups19BypassFrequency, ups19BypassNumLines,
|
|
ups19BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 5 }
|
|
|
|
ups19BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups19AlarmsPresent, ups19AlarmDescr, ups19AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups19BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 6 }
|
|
|
|
ups19BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups19TestId, ups19TestSpinLock,
|
|
ups19TestResultsSummary, ups19TestResultsDetail,
|
|
ups19TestStartTime, ups19TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 7 }
|
|
|
|
ups19BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups19ShutdownType, ups19ShutdownAfterDelay,
|
|
ups19StartupAfterDelay, ups19RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups19BasicGroups 8 }
|
|
|
|
ups19FullGroups OBJECT IDENTIFIER ::= { ups19Groups 3 }
|
|
|
|
ups19FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups19IdentManufacturer, ups19IdentModel,
|
|
ups19IdentUPSSoftwareVersion,
|
|
ups19IdentAgentSoftwareVersion, ups19IdentName,
|
|
ups19IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups19FullGroups 1 }
|
|
|
|
ups19FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups19BatteryStatus, ups19SecondsOnBattery,
|
|
ups19EstimatedMinutesRemaining,
|
|
ups19EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 2 }
|
|
|
|
ups19FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups19InputLineBads, ups19InputNumLines,
|
|
ups19InputFrequency, ups19InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 3 }
|
|
|
|
ups19FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups19OutputSource, ups19OutputFrequency,
|
|
ups19OutputNumLines, ups19OutputVoltage,
|
|
ups19OutputCurrent, ups19OutputPower,
|
|
ups19OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 4 }
|
|
|
|
ups19FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups19BypassFrequency, ups19BypassNumLines,
|
|
ups19BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 5 }
|
|
|
|
ups19FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups19AlarmsPresent, ups19AlarmDescr, ups19AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups19FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 6 }
|
|
|
|
ups19FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups19TestId, ups19TestSpinLock,
|
|
ups19TestResultsSummary, ups19TestResultsDetail,
|
|
ups19TestStartTime, ups19TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 7 }
|
|
|
|
ups19FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups19ShutdownType, ups19ShutdownAfterDelay,
|
|
ups19StartupAfterDelay, ups19RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups19FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups19FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 20 data
|
|
--
|
|
|
|
upsModule20 OBJECT IDENTIFIER ::= { upsModular 21 }
|
|
ups20Objects OBJECT IDENTIFIER ::= { upsModule20 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups20IdentName and
|
|
-- ups20IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups20Ident OBJECT IDENTIFIER ::= { ups20Objects 1 }
|
|
|
|
ups20IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups20Ident 1 }
|
|
|
|
ups20IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups20Ident 2 }
|
|
|
|
ups20IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups20IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups20Ident 3 }
|
|
|
|
ups20IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups20IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups20Ident 4 }
|
|
|
|
ups20IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups20Ident 5 }
|
|
|
|
ups20IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups20Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups20Battery OBJECT IDENTIFIER ::= { ups20Objects 2 }
|
|
|
|
ups20BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups20ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups20ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups20Battery 1 }
|
|
|
|
ups20SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups20Battery 2 }
|
|
|
|
ups20EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups20Battery 3 }
|
|
|
|
ups20EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups20Battery 4 }
|
|
|
|
ups20BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups20Battery 5 }
|
|
|
|
ups20BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups20Battery 6 }
|
|
|
|
ups20BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups20Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups20Input OBJECT IDENTIFIER ::= { ups20Objects 3 }
|
|
|
|
ups20InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups20Input 1 }
|
|
|
|
|
|
ups20InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups20Input 2 }
|
|
|
|
ups20InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups20InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups20InputNumLines."
|
|
::= { ups20Input 3 }
|
|
|
|
ups20InputEntry OBJECT-TYPE
|
|
SYNTAX Ups20InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups20InputLineIndex }
|
|
::= { ups20InputTable 1 }
|
|
|
|
Ups20InputEntry ::= SEQUENCE {
|
|
ups20InputLineIndex PositiveInteger,
|
|
ups20InputFrequency NonNegativeInteger,
|
|
ups20InputVoltage NonNegativeInteger,
|
|
ups20InputCurrent NonNegativeInteger,
|
|
ups20InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups20InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups20InputEntry 1 }
|
|
|
|
ups20InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups20InputEntry 2 }
|
|
|
|
ups20InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups20InputEntry 3 }
|
|
|
|
ups20InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups20InputEntry 4 }
|
|
|
|
ups20InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups20InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups20Output OBJECT IDENTIFIER ::= { ups20Objects 4 }
|
|
|
|
ups20OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups20Output 1 }
|
|
|
|
ups20OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups20Output 2 }
|
|
|
|
ups20OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups20Output 3 }
|
|
|
|
ups20OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups20OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups20OutputNumLines."
|
|
::= { ups20Output 4 }
|
|
|
|
ups20OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups20OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups20OutputLineIndex }
|
|
::= { ups20OutputTable 1 }
|
|
|
|
Ups20OutputEntry ::= SEQUENCE {
|
|
ups20OutputLineIndex PositiveInteger,
|
|
ups20OutputVoltage NonNegativeInteger,
|
|
ups20OutputCurrent NonNegativeInteger,
|
|
ups20OutputPower NonNegativeInteger,
|
|
ups20OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups20OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups20OutputEntry 1 }
|
|
|
|
ups20OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups20OutputEntry 2 }
|
|
|
|
ups20OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups20OutputEntry 3 }
|
|
|
|
ups20OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups20OutputEntry 4 }
|
|
|
|
ups20OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups20OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups20Bypass OBJECT IDENTIFIER ::= { ups20Objects 5 }
|
|
|
|
ups20BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups20Bypass 1 }
|
|
|
|
ups20BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups20Bypass 2 }
|
|
|
|
ups20BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups20BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups20BypassNumLines."
|
|
::= { ups20Bypass 3 }
|
|
|
|
ups20BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups20BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups20BypassLineIndex }
|
|
::= { ups20BypassTable 1 }
|
|
|
|
Ups20BypassEntry ::= SEQUENCE {
|
|
ups20BypassLineIndex PositiveInteger,
|
|
ups20BypassVoltage NonNegativeInteger,
|
|
ups20BypassCurrent NonNegativeInteger,
|
|
ups20BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups20BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups20BypassEntry 1 }
|
|
|
|
ups20BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups20BypassEntry 2 }
|
|
|
|
ups20BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups20BypassEntry 3 }
|
|
|
|
ups20BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups20BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups20Alarm OBJECT IDENTIFIER ::= { ups20Objects 6 }
|
|
|
|
ups20AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups20Alarm 1 }
|
|
|
|
ups20AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups20AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups20AlarmId equal to 1, and increments the value of
|
|
ups20AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups20AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups20AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups20AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups20AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups20AlarmsPresent."
|
|
::= { ups20Alarm 2 }
|
|
|
|
ups20AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups20AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups20AlarmId }
|
|
::= { ups20AlarmTable 1 }
|
|
|
|
Ups20AlarmEntry ::= SEQUENCE {
|
|
ups20AlarmId PositiveInteger,
|
|
ups20AlarmDescr AutonomousType,
|
|
ups20AlarmTime TimeStamp
|
|
}
|
|
|
|
ups20AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups20AlarmEntry 1 }
|
|
|
|
ups20AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups20AlarmEntry 2 }
|
|
|
|
ups20AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups20AlarmTime shall equal
|
|
0."
|
|
::= { ups20AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups20WellKnownAlarms OBJECT IDENTIFIER ::= { ups20Alarm 3 }
|
|
ups20AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups20WellKnownAlarms 1 }
|
|
|
|
ups20AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups20WellKnownAlarms 2 }
|
|
|
|
ups20AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups20ConfigLowBattTime."
|
|
::= { ups20WellKnownAlarms 3 }
|
|
|
|
|
|
ups20AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups20WellKnownAlarms 4 }
|
|
|
|
ups20AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups20WellKnownAlarms 5 }
|
|
|
|
ups20AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups20WellKnownAlarms 6 }
|
|
|
|
ups20AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups20WellKnownAlarms 7 }
|
|
|
|
ups20AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups20WellKnownAlarms 8 }
|
|
|
|
ups20AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups20WellKnownAlarms 9 }
|
|
|
|
ups20AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups20WellKnownAlarms 10 }
|
|
|
|
ups20AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups20WellKnownAlarms 11 }
|
|
|
|
ups20AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups20WellKnownAlarms 12 }
|
|
|
|
ups20AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups20WellKnownAlarms 13 }
|
|
|
|
ups20AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups20WellKnownAlarms 14 }
|
|
|
|
ups20AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups20WellKnownAlarms 15 }
|
|
|
|
ups20AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups20WellKnownAlarms 16 }
|
|
|
|
ups20AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups20WellKnownAlarms 17 }
|
|
|
|
ups20AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups20WellKnownAlarms 18 }
|
|
|
|
ups20AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups20WellKnownAlarms 19 }
|
|
|
|
ups20AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups20WellKnownAlarms 20 }
|
|
|
|
ups20AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups20WellKnownAlarms 21 }
|
|
|
|
ups20AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups20ShutdownAfterDelay countdown is underway."
|
|
::= { ups20WellKnownAlarms 22 }
|
|
|
|
ups20AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups20WellKnownAlarms 23 }
|
|
|
|
ups20AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups20WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups20Test OBJECT IDENTIFIER ::= { ups20Objects 7 }
|
|
|
|
ups20TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups20TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups20TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups20TestId variable to
|
|
ups20TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups20TestNoTestsInitiated is returned."
|
|
::= { ups20Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups20TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups20TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups20TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups20TestResultsSummary */
|
|
get (upsTestSpinLock, ups20TestResultsSummary,
|
|
ups20TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups20TestResultsSummary,
|
|
ups20TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups20TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups20TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups20Test 2 }
|
|
|
|
ups20TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups20TestId to ups20TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups20Test 3 }
|
|
|
|
ups20TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups20TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups20Test 4 }
|
|
|
|
ups20TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups20TestResultsSummary is noTestsInitiated(6),
|
|
ups20TestStartTime has the value 0."
|
|
::= { ups20Test 5 }
|
|
|
|
ups20TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups20TestResultsSummary is noTestsInitiated(6),
|
|
ups20TestElapsedTime has the value 0."
|
|
::= { ups20Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups20WellKnownTests OBJECT IDENTIFIER ::= { ups20Test 7 }
|
|
|
|
|
|
ups20TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups20WellKnownTests 1 }
|
|
|
|
ups20TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups20WellKnownTests 2 }
|
|
|
|
ups20TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups20WellKnownTests 3 }
|
|
|
|
ups20TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups20WellKnownTests 4 }
|
|
|
|
ups20TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups20WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups20Control OBJECT IDENTIFIER ::= { ups20Objects 8 }
|
|
|
|
ups20ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups20ShutdownAfterDelay and ups20RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups20Control 1 }
|
|
|
|
ups20ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups20ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups20ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups20ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups20ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups20ShutdownAfterDelay already in effect."
|
|
::= { ups20Control 2 }
|
|
|
|
ups20StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups20StartupAfterDelay
|
|
countdown or ups20RebootWithDuration countdown in
|
|
progress. When read, ups20StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups20Control 3 }
|
|
|
|
ups20RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups20ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups20RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups20Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups20Traps OBJECT IDENTIFIER ::= { upsModule20 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups20TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups20EstimatedMinutesRemaining, ups20SecondsOnBattery,
|
|
ups20ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups20Traps 1 }
|
|
|
|
ups20TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups20TestId, ups20TestSpinLock,
|
|
ups20TestResultsSummary, ups20TestResultsDetail,
|
|
ups20TestStartTime, ups20TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups20Traps 2 }
|
|
|
|
ups20TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups20AlarmId, ups20AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups20AlarmOnBattery and
|
|
ups20AlarmTestInProgress."
|
|
::= { ups20Traps 3 }
|
|
|
|
ups20TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups20AlarmId, ups20AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups20AlarmTestInProgress."
|
|
::= { ups20Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups20Conformance OBJECT IDENTIFIER ::= { upsModule20 3 }
|
|
|
|
ups20Compliances OBJECT IDENTIFIER ::= { ups20Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups20SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups20SubsetIdentGroup,
|
|
ups20SubsetBatteryGroup, ups20SubsetInputGroup,
|
|
ups20SubsetOutputGroup, ups20SubsetAlarmGroup,
|
|
ups20SubsetControlGroup }
|
|
|
|
OBJECT ups20BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups20AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups20AlarmOnBattery, ups20AlarmLowBattery,
|
|
ups20AlarmInputBad, ups20AlarmUpsOutputOff,
|
|
ups20AlarmUpsSystemOff, and ups20AlarmTestInProgress."
|
|
|
|
OBJECT ups20OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups20ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups20Compliances 1 }
|
|
|
|
ups20BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups20BasicIdentGroup,
|
|
ups20BasicBatteryGroup, ups20BasicInputGroup,
|
|
ups20BasicOutputGroup, ups20BasicAlarmGroup,
|
|
ups20BasicTestGroup, ups20BasicControlGroup }
|
|
|
|
OBJECT ups20AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups20AlarmOnBattery, ups20AlarmLowBattery,
|
|
ups20AlarmDepletedBattery, ups20AlarmTempBad,
|
|
ups20AlarmInputBad, ups20AlarmOutputOverload,
|
|
ups20AlarmOnBypass, ups20AlarmBypassBad,
|
|
ups20AlarmOutputOffAsRequested,
|
|
ups20AlarmUpsOffAsRequested, ups20AlarmUpsOutputOff,
|
|
ups20AlarmUpsSystemOff, ups20AlarmGeneralFault,
|
|
ups20AlarmDiagnosticTestFailed,
|
|
ups20AlarmCommunicationsLost, ups20AlarmShutdownPending,
|
|
and ups20AlarmTestInProgress."
|
|
|
|
OBJECT ups20TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups20TestNoTestsInitiated."
|
|
|
|
OBJECT ups20OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups20BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups20BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups20ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups20Compliances 2 }
|
|
|
|
ups20FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups20FullIdentGroup, ups20FullBatteryGroup,
|
|
ups20FullInputGroup, ups20FullOutputGroup,
|
|
ups20FullAlarmGroup, ups20FullTestGroup,
|
|
ups20FullControlGroup }
|
|
|
|
OBJECT ups20AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups20AlarmBatteryBad, ups20AlarmOnBattery,
|
|
ups20AlarmLowBattery, ups20AlarmDepletedBattery,
|
|
ups20AlarmTempBad, ups20AlarmInputBad, ups20AlarmOnBypass,
|
|
ups20AlarmBypassBad, ups20AlarmOutputOffAsRequested,
|
|
ups20AlarmUpsOffAsRequested, ups20AlarmUpsOutputOff,
|
|
ups20AlarmUpsSystemOff, ups20AlarmGeneralFault,
|
|
ups20AlarmDiagnosticTestFailed,
|
|
ups20AlarmCommunicationsLost, ups20AlarmShutdownPending,
|
|
and ups20AlarmTestInProgress."
|
|
|
|
OBJECT ups20TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups20TestNoTestsInitiated,
|
|
ups20TestGeneralSystemsTest, and
|
|
ups20TestQuickBatteryTest."
|
|
|
|
OBJECT ups20OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups20FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups20FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups20ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups20Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups20Groups OBJECT IDENTIFIER ::= { ups20Conformance 2 }
|
|
|
|
ups20SubsetGroups OBJECT IDENTIFIER ::= { ups20Groups 1 }
|
|
|
|
ups20SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups20IdentManufacturer, ups20IdentModel,
|
|
ups20IdentAgentSoftwareVersion, ups20IdentName,
|
|
ups20IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups20SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups20SubsetGroups 1 }
|
|
|
|
ups20SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups20BatteryStatus, ups20SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups20SubsetGroups 2 }
|
|
|
|
ups20SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups20InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups20SubsetGroups 3 }
|
|
|
|
ups20SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups20OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups20SubsetGroups 4 }
|
|
|
|
|
|
-- { ups20SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups20SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups20AlarmsPresent, ups20AlarmDescr, ups20AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups20SubsetGroups 6 }
|
|
|
|
-- { ups20SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups20SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups20ShutdownType, ups20ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups20SubsetGroups 8 }
|
|
|
|
ups20BasicGroups OBJECT IDENTIFIER ::= { ups20Groups 2 }
|
|
|
|
ups20BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups20IdentManufacturer, ups20IdentModel,
|
|
ups20IdentUPSSoftwareVersion,
|
|
ups20IdentAgentSoftwareVersion, ups20IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 1 }
|
|
|
|
ups20BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups20BatteryStatus, ups20SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 2 }
|
|
|
|
ups20BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups20InputLineBads, ups20InputNumLines,
|
|
ups20InputFrequency, ups20InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 3 }
|
|
|
|
ups20BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups20OutputSource, ups20OutputFrequency,
|
|
ups20OutputNumLines, ups20OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 4 }
|
|
|
|
ups20BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups20BypassFrequency, ups20BypassNumLines,
|
|
ups20BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 5 }
|
|
|
|
ups20BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups20AlarmsPresent, ups20AlarmDescr, ups20AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups20BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 6 }
|
|
|
|
ups20BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups20TestId, ups20TestSpinLock,
|
|
ups20TestResultsSummary, ups20TestResultsDetail,
|
|
ups20TestStartTime, ups20TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 7 }
|
|
|
|
ups20BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups20ShutdownType, ups20ShutdownAfterDelay,
|
|
ups20StartupAfterDelay, ups20RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups20BasicGroups 8 }
|
|
|
|
ups20FullGroups OBJECT IDENTIFIER ::= { ups20Groups 3 }
|
|
|
|
ups20FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups20IdentManufacturer, ups20IdentModel,
|
|
ups20IdentUPSSoftwareVersion,
|
|
ups20IdentAgentSoftwareVersion, ups20IdentName,
|
|
ups20IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups20FullGroups 1 }
|
|
|
|
ups20FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups20BatteryStatus, ups20SecondsOnBattery,
|
|
ups20EstimatedMinutesRemaining,
|
|
ups20EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 2 }
|
|
|
|
ups20FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups20InputLineBads, ups20InputNumLines,
|
|
ups20InputFrequency, ups20InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 3 }
|
|
|
|
ups20FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups20OutputSource, ups20OutputFrequency,
|
|
ups20OutputNumLines, ups20OutputVoltage,
|
|
ups20OutputCurrent, ups20OutputPower,
|
|
ups20OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 4 }
|
|
|
|
ups20FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups20BypassFrequency, ups20BypassNumLines,
|
|
ups20BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 5 }
|
|
|
|
ups20FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups20AlarmsPresent, ups20AlarmDescr, ups20AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups20FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 6 }
|
|
|
|
ups20FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups20TestId, ups20TestSpinLock,
|
|
ups20TestResultsSummary, ups20TestResultsDetail,
|
|
ups20TestStartTime, ups20TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 7 }
|
|
|
|
ups20FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups20ShutdownType, ups20ShutdownAfterDelay,
|
|
ups20StartupAfterDelay, ups20RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups20FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups20FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 21 data
|
|
--
|
|
|
|
upsModule21 OBJECT IDENTIFIER ::= { upsModular 22 }
|
|
ups21Objects OBJECT IDENTIFIER ::= { upsModule21 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups21IdentName and
|
|
-- ups21IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups21Ident OBJECT IDENTIFIER ::= { ups21Objects 1 }
|
|
|
|
ups21IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups21Ident 1 }
|
|
|
|
ups21IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups21Ident 2 }
|
|
|
|
ups21IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups21IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups21Ident 3 }
|
|
|
|
ups21IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups21IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups21Ident 4 }
|
|
|
|
ups21IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups21Ident 5 }
|
|
|
|
ups21IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups21Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups21Battery OBJECT IDENTIFIER ::= { ups21Objects 2 }
|
|
|
|
ups21BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups21ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups21ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups21Battery 1 }
|
|
|
|
ups21SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups21Battery 2 }
|
|
|
|
ups21EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups21Battery 3 }
|
|
|
|
ups21EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups21Battery 4 }
|
|
|
|
ups21BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups21Battery 5 }
|
|
|
|
ups21BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups21Battery 6 }
|
|
|
|
ups21BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups21Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups21Input OBJECT IDENTIFIER ::= { ups21Objects 3 }
|
|
|
|
ups21InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups21Input 1 }
|
|
|
|
|
|
ups21InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups21Input 2 }
|
|
|
|
ups21InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups21InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups21InputNumLines."
|
|
::= { ups21Input 3 }
|
|
|
|
ups21InputEntry OBJECT-TYPE
|
|
SYNTAX Ups21InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups21InputLineIndex }
|
|
::= { ups21InputTable 1 }
|
|
|
|
Ups21InputEntry ::= SEQUENCE {
|
|
ups21InputLineIndex PositiveInteger,
|
|
ups21InputFrequency NonNegativeInteger,
|
|
ups21InputVoltage NonNegativeInteger,
|
|
ups21InputCurrent NonNegativeInteger,
|
|
ups21InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups21InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups21InputEntry 1 }
|
|
|
|
ups21InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups21InputEntry 2 }
|
|
|
|
ups21InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups21InputEntry 3 }
|
|
|
|
ups21InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups21InputEntry 4 }
|
|
|
|
ups21InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups21InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups21Output OBJECT IDENTIFIER ::= { ups21Objects 4 }
|
|
|
|
ups21OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups21Output 1 }
|
|
|
|
ups21OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups21Output 2 }
|
|
|
|
ups21OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups21Output 3 }
|
|
|
|
ups21OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups21OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups21OutputNumLines."
|
|
::= { ups21Output 4 }
|
|
|
|
ups21OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups21OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups21OutputLineIndex }
|
|
::= { ups21OutputTable 1 }
|
|
|
|
Ups21OutputEntry ::= SEQUENCE {
|
|
ups21OutputLineIndex PositiveInteger,
|
|
ups21OutputVoltage NonNegativeInteger,
|
|
ups21OutputCurrent NonNegativeInteger,
|
|
ups21OutputPower NonNegativeInteger,
|
|
ups21OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups21OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups21OutputEntry 1 }
|
|
|
|
ups21OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups21OutputEntry 2 }
|
|
|
|
ups21OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups21OutputEntry 3 }
|
|
|
|
ups21OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups21OutputEntry 4 }
|
|
|
|
ups21OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups21OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups21Bypass OBJECT IDENTIFIER ::= { ups21Objects 5 }
|
|
|
|
ups21BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups21Bypass 1 }
|
|
|
|
ups21BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups21Bypass 2 }
|
|
|
|
ups21BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups21BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups21BypassNumLines."
|
|
::= { ups21Bypass 3 }
|
|
|
|
ups21BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups21BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups21BypassLineIndex }
|
|
::= { ups21BypassTable 1 }
|
|
|
|
Ups21BypassEntry ::= SEQUENCE {
|
|
ups21BypassLineIndex PositiveInteger,
|
|
ups21BypassVoltage NonNegativeInteger,
|
|
ups21BypassCurrent NonNegativeInteger,
|
|
ups21BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups21BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups21BypassEntry 1 }
|
|
|
|
ups21BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups21BypassEntry 2 }
|
|
|
|
ups21BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups21BypassEntry 3 }
|
|
|
|
ups21BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups21BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups21Alarm OBJECT IDENTIFIER ::= { ups21Objects 6 }
|
|
|
|
ups21AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups21Alarm 1 }
|
|
|
|
ups21AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups21AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups21AlarmId equal to 1, and increments the value of
|
|
ups21AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups21AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups21AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups21AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups21AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups21AlarmsPresent."
|
|
::= { ups21Alarm 2 }
|
|
|
|
ups21AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups21AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups21AlarmId }
|
|
::= { ups21AlarmTable 1 }
|
|
|
|
Ups21AlarmEntry ::= SEQUENCE {
|
|
ups21AlarmId PositiveInteger,
|
|
ups21AlarmDescr AutonomousType,
|
|
ups21AlarmTime TimeStamp
|
|
}
|
|
|
|
ups21AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups21AlarmEntry 1 }
|
|
|
|
ups21AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups21AlarmEntry 2 }
|
|
|
|
ups21AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups21AlarmTime shall equal
|
|
0."
|
|
::= { ups21AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups21WellKnownAlarms OBJECT IDENTIFIER ::= { ups21Alarm 3 }
|
|
ups21AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups21WellKnownAlarms 1 }
|
|
|
|
ups21AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups21WellKnownAlarms 2 }
|
|
|
|
ups21AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups21ConfigLowBattTime."
|
|
::= { ups21WellKnownAlarms 3 }
|
|
|
|
|
|
ups21AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups21WellKnownAlarms 4 }
|
|
|
|
ups21AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups21WellKnownAlarms 5 }
|
|
|
|
ups21AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups21WellKnownAlarms 6 }
|
|
|
|
ups21AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups21WellKnownAlarms 7 }
|
|
|
|
ups21AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups21WellKnownAlarms 8 }
|
|
|
|
ups21AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups21WellKnownAlarms 9 }
|
|
|
|
ups21AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups21WellKnownAlarms 10 }
|
|
|
|
ups21AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups21WellKnownAlarms 11 }
|
|
|
|
ups21AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups21WellKnownAlarms 12 }
|
|
|
|
ups21AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups21WellKnownAlarms 13 }
|
|
|
|
ups21AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups21WellKnownAlarms 14 }
|
|
|
|
ups21AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups21WellKnownAlarms 15 }
|
|
|
|
ups21AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups21WellKnownAlarms 16 }
|
|
|
|
ups21AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups21WellKnownAlarms 17 }
|
|
|
|
ups21AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups21WellKnownAlarms 18 }
|
|
|
|
ups21AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups21WellKnownAlarms 19 }
|
|
|
|
ups21AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups21WellKnownAlarms 20 }
|
|
|
|
ups21AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups21WellKnownAlarms 21 }
|
|
|
|
ups21AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups21ShutdownAfterDelay countdown is underway."
|
|
::= { ups21WellKnownAlarms 22 }
|
|
|
|
ups21AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups21WellKnownAlarms 23 }
|
|
|
|
ups21AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups21WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups21Test OBJECT IDENTIFIER ::= { ups21Objects 7 }
|
|
|
|
ups21TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups21TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups21TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups21TestId variable to
|
|
ups21TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups21TestNoTestsInitiated is returned."
|
|
::= { ups21Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups21TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups21TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups21TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups21TestResultsSummary */
|
|
get (upsTestSpinLock, ups21TestResultsSummary,
|
|
ups21TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups21TestResultsSummary,
|
|
ups21TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups21TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups21TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups21Test 2 }
|
|
|
|
ups21TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups21TestId to ups21TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups21Test 3 }
|
|
|
|
ups21TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups21TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups21Test 4 }
|
|
|
|
ups21TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups21TestResultsSummary is noTestsInitiated(6),
|
|
ups21TestStartTime has the value 0."
|
|
::= { ups21Test 5 }
|
|
|
|
ups21TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups21TestResultsSummary is noTestsInitiated(6),
|
|
ups21TestElapsedTime has the value 0."
|
|
::= { ups21Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups21WellKnownTests OBJECT IDENTIFIER ::= { ups21Test 7 }
|
|
|
|
|
|
ups21TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups21WellKnownTests 1 }
|
|
|
|
ups21TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups21WellKnownTests 2 }
|
|
|
|
ups21TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups21WellKnownTests 3 }
|
|
|
|
ups21TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups21WellKnownTests 4 }
|
|
|
|
ups21TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups21WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups21Control OBJECT IDENTIFIER ::= { ups21Objects 8 }
|
|
|
|
ups21ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups21ShutdownAfterDelay and ups21RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups21Control 1 }
|
|
|
|
ups21ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups21ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups21ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups21ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups21ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups21ShutdownAfterDelay already in effect."
|
|
::= { ups21Control 2 }
|
|
|
|
ups21StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups21StartupAfterDelay
|
|
countdown or ups21RebootWithDuration countdown in
|
|
progress. When read, ups21StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups21Control 3 }
|
|
|
|
ups21RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups21ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups21RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups21Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups21Traps OBJECT IDENTIFIER ::= { upsModule21 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups21TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups21EstimatedMinutesRemaining, ups21SecondsOnBattery,
|
|
ups21ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups21Traps 1 }
|
|
|
|
ups21TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups21TestId, ups21TestSpinLock,
|
|
ups21TestResultsSummary, ups21TestResultsDetail,
|
|
ups21TestStartTime, ups21TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups21Traps 2 }
|
|
|
|
ups21TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups21AlarmId, ups21AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups21AlarmOnBattery and
|
|
ups21AlarmTestInProgress."
|
|
::= { ups21Traps 3 }
|
|
|
|
ups21TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups21AlarmId, ups21AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups21AlarmTestInProgress."
|
|
::= { ups21Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups21Conformance OBJECT IDENTIFIER ::= { upsModule21 3 }
|
|
|
|
ups21Compliances OBJECT IDENTIFIER ::= { ups21Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups21SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups21SubsetIdentGroup,
|
|
ups21SubsetBatteryGroup, ups21SubsetInputGroup,
|
|
ups21SubsetOutputGroup, ups21SubsetAlarmGroup,
|
|
ups21SubsetControlGroup }
|
|
|
|
OBJECT ups21BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups21AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups21AlarmOnBattery, ups21AlarmLowBattery,
|
|
ups21AlarmInputBad, ups21AlarmUpsOutputOff,
|
|
ups21AlarmUpsSystemOff, and ups21AlarmTestInProgress."
|
|
|
|
OBJECT ups21OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups21ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups21Compliances 1 }
|
|
|
|
ups21BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups21BasicIdentGroup,
|
|
ups21BasicBatteryGroup, ups21BasicInputGroup,
|
|
ups21BasicOutputGroup, ups21BasicAlarmGroup,
|
|
ups21BasicTestGroup, ups21BasicControlGroup }
|
|
|
|
|
|
OBJECT ups21AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups21AlarmOnBattery, ups21AlarmLowBattery,
|
|
ups21AlarmDepletedBattery, ups21AlarmTempBad,
|
|
ups21AlarmInputBad, ups21AlarmOutputOverload,
|
|
ups21AlarmOnBypass, ups21AlarmBypassBad,
|
|
ups21AlarmOutputOffAsRequested,
|
|
ups21AlarmUpsOffAsRequested, ups21AlarmUpsOutputOff,
|
|
ups21AlarmUpsSystemOff, ups21AlarmGeneralFault,
|
|
ups21AlarmDiagnosticTestFailed,
|
|
ups21AlarmCommunicationsLost, ups21AlarmShutdownPending,
|
|
and ups21AlarmTestInProgress."
|
|
|
|
OBJECT ups21TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups21TestNoTestsInitiated."
|
|
|
|
OBJECT ups21OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups21BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups21BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups21ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups21Compliances 2 }
|
|
|
|
ups21FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups21FullIdentGroup, ups21FullBatteryGroup,
|
|
ups21FullInputGroup, ups21FullOutputGroup,
|
|
ups21FullAlarmGroup, ups21FullTestGroup,
|
|
ups21FullControlGroup }
|
|
|
|
OBJECT ups21AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups21AlarmBatteryBad, ups21AlarmOnBattery,
|
|
ups21AlarmLowBattery, ups21AlarmDepletedBattery,
|
|
ups21AlarmTempBad, ups21AlarmInputBad, ups21AlarmOnBypass,
|
|
ups21AlarmBypassBad, ups21AlarmOutputOffAsRequested,
|
|
ups21AlarmUpsOffAsRequested, ups21AlarmUpsOutputOff,
|
|
ups21AlarmUpsSystemOff, ups21AlarmGeneralFault,
|
|
ups21AlarmDiagnosticTestFailed,
|
|
ups21AlarmCommunicationsLost, ups21AlarmShutdownPending,
|
|
and ups21AlarmTestInProgress."
|
|
|
|
OBJECT ups21TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups21TestNoTestsInitiated,
|
|
ups21TestGeneralSystemsTest, and
|
|
ups21TestQuickBatteryTest."
|
|
|
|
OBJECT ups21OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups21FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups21FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups21ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups21Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups21Groups OBJECT IDENTIFIER ::= { ups21Conformance 2 }
|
|
|
|
ups21SubsetGroups OBJECT IDENTIFIER ::= { ups21Groups 1 }
|
|
|
|
ups21SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups21IdentManufacturer, ups21IdentModel,
|
|
ups21IdentAgentSoftwareVersion, ups21IdentName,
|
|
ups21IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups21SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups21SubsetGroups 1 }
|
|
|
|
ups21SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups21BatteryStatus, ups21SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups21SubsetGroups 2 }
|
|
|
|
ups21SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups21InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups21SubsetGroups 3 }
|
|
|
|
ups21SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups21OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups21SubsetGroups 4 }
|
|
|
|
|
|
-- { ups21SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups21SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups21AlarmsPresent, ups21AlarmDescr, ups21AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups21SubsetGroups 6 }
|
|
|
|
-- { ups21SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups21SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups21ShutdownType, ups21ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups21SubsetGroups 8 }
|
|
|
|
ups21BasicGroups OBJECT IDENTIFIER ::= { ups21Groups 2 }
|
|
|
|
ups21BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups21IdentManufacturer, ups21IdentModel,
|
|
ups21IdentUPSSoftwareVersion,
|
|
ups21IdentAgentSoftwareVersion, ups21IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 1 }
|
|
|
|
ups21BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups21BatteryStatus, ups21SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 2 }
|
|
|
|
ups21BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups21InputLineBads, ups21InputNumLines,
|
|
ups21InputFrequency, ups21InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 3 }
|
|
|
|
ups21BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups21OutputSource, ups21OutputFrequency,
|
|
ups21OutputNumLines, ups21OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 4 }
|
|
|
|
ups21BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups21BypassFrequency, ups21BypassNumLines,
|
|
ups21BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 5 }
|
|
|
|
ups21BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups21AlarmsPresent, ups21AlarmDescr, ups21AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups21BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 6 }
|
|
|
|
ups21BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups21TestId, ups21TestSpinLock,
|
|
ups21TestResultsSummary, ups21TestResultsDetail,
|
|
ups21TestStartTime, ups21TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 7 }
|
|
|
|
ups21BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups21ShutdownType, ups21ShutdownAfterDelay,
|
|
ups21StartupAfterDelay, ups21RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups21BasicGroups 8 }
|
|
|
|
ups21FullGroups OBJECT IDENTIFIER ::= { ups21Groups 3 }
|
|
|
|
ups21FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups21IdentManufacturer, ups21IdentModel,
|
|
ups21IdentUPSSoftwareVersion,
|
|
ups21IdentAgentSoftwareVersion, ups21IdentName,
|
|
ups21IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups21FullGroups 1 }
|
|
|
|
ups21FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups21BatteryStatus, ups21SecondsOnBattery,
|
|
ups21EstimatedMinutesRemaining,
|
|
ups21EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 2 }
|
|
|
|
ups21FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups21InputLineBads, ups21InputNumLines,
|
|
ups21InputFrequency, ups21InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 3 }
|
|
|
|
ups21FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups21OutputSource, ups21OutputFrequency,
|
|
ups21OutputNumLines, ups21OutputVoltage,
|
|
ups21OutputCurrent, ups21OutputPower,
|
|
ups21OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 4 }
|
|
|
|
ups21FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups21BypassFrequency, ups21BypassNumLines,
|
|
ups21BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 5 }
|
|
|
|
ups21FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups21AlarmsPresent, ups21AlarmDescr, ups21AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups21FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 6 }
|
|
|
|
ups21FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups21TestId, ups21TestSpinLock,
|
|
ups21TestResultsSummary, ups21TestResultsDetail,
|
|
ups21TestStartTime, ups21TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 7 }
|
|
|
|
ups21FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups21ShutdownType, ups21ShutdownAfterDelay,
|
|
ups21StartupAfterDelay, ups21RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups21FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups21FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 22 data
|
|
--
|
|
|
|
upsModule22 OBJECT IDENTIFIER ::= { upsModular 23 }
|
|
ups22Objects OBJECT IDENTIFIER ::= { upsModule22 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups22IdentName and
|
|
-- ups22IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups22Ident OBJECT IDENTIFIER ::= { ups22Objects 1 }
|
|
|
|
ups22IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups22Ident 1 }
|
|
|
|
ups22IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups22Ident 2 }
|
|
|
|
ups22IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups22IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups22Ident 3 }
|
|
|
|
ups22IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups22IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups22Ident 4 }
|
|
|
|
ups22IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups22Ident 5 }
|
|
|
|
ups22IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups22Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups22Battery OBJECT IDENTIFIER ::= { ups22Objects 2 }
|
|
|
|
ups22BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups22ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups22ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups22Battery 1 }
|
|
|
|
ups22SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups22Battery 2 }
|
|
|
|
ups22EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups22Battery 3 }
|
|
|
|
ups22EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups22Battery 4 }
|
|
|
|
ups22BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups22Battery 5 }
|
|
|
|
ups22BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups22Battery 6 }
|
|
|
|
ups22BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups22Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups22Input OBJECT IDENTIFIER ::= { ups22Objects 3 }
|
|
|
|
ups22InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups22Input 1 }
|
|
|
|
|
|
ups22InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups22Input 2 }
|
|
|
|
ups22InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups22InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups22InputNumLines."
|
|
::= { ups22Input 3 }
|
|
|
|
ups22InputEntry OBJECT-TYPE
|
|
SYNTAX Ups22InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups22InputLineIndex }
|
|
::= { ups22InputTable 1 }
|
|
|
|
Ups22InputEntry ::= SEQUENCE {
|
|
ups22InputLineIndex PositiveInteger,
|
|
ups22InputFrequency NonNegativeInteger,
|
|
ups22InputVoltage NonNegativeInteger,
|
|
ups22InputCurrent NonNegativeInteger,
|
|
ups22InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups22InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups22InputEntry 1 }
|
|
|
|
ups22InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups22InputEntry 2 }
|
|
|
|
ups22InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups22InputEntry 3 }
|
|
|
|
ups22InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups22InputEntry 4 }
|
|
|
|
ups22InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups22InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups22Output OBJECT IDENTIFIER ::= { ups22Objects 4 }
|
|
|
|
ups22OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups22Output 1 }
|
|
|
|
ups22OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups22Output 2 }
|
|
|
|
ups22OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups22Output 3 }
|
|
|
|
ups22OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups22OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups22OutputNumLines."
|
|
::= { ups22Output 4 }
|
|
|
|
ups22OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups22OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups22OutputLineIndex }
|
|
::= { ups22OutputTable 1 }
|
|
|
|
Ups22OutputEntry ::= SEQUENCE {
|
|
ups22OutputLineIndex PositiveInteger,
|
|
ups22OutputVoltage NonNegativeInteger,
|
|
ups22OutputCurrent NonNegativeInteger,
|
|
ups22OutputPower NonNegativeInteger,
|
|
ups22OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups22OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups22OutputEntry 1 }
|
|
|
|
ups22OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups22OutputEntry 2 }
|
|
|
|
ups22OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups22OutputEntry 3 }
|
|
|
|
ups22OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups22OutputEntry 4 }
|
|
|
|
ups22OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups22OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups22Bypass OBJECT IDENTIFIER ::= { ups22Objects 5 }
|
|
|
|
ups22BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups22Bypass 1 }
|
|
|
|
ups22BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups22Bypass 2 }
|
|
|
|
ups22BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups22BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups22BypassNumLines."
|
|
::= { ups22Bypass 3 }
|
|
|
|
ups22BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups22BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups22BypassLineIndex }
|
|
::= { ups22BypassTable 1 }
|
|
|
|
Ups22BypassEntry ::= SEQUENCE {
|
|
ups22BypassLineIndex PositiveInteger,
|
|
ups22BypassVoltage NonNegativeInteger,
|
|
ups22BypassCurrent NonNegativeInteger,
|
|
ups22BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups22BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups22BypassEntry 1 }
|
|
|
|
ups22BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups22BypassEntry 2 }
|
|
|
|
ups22BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups22BypassEntry 3 }
|
|
|
|
ups22BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups22BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups22Alarm OBJECT IDENTIFIER ::= { ups22Objects 6 }
|
|
|
|
ups22AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups22Alarm 1 }
|
|
|
|
ups22AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups22AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups22AlarmId equal to 1, and increments the value of
|
|
ups22AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups22AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups22AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups22AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups22AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups22AlarmsPresent."
|
|
::= { ups22Alarm 2 }
|
|
|
|
ups22AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups22AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups22AlarmId }
|
|
::= { ups22AlarmTable 1 }
|
|
|
|
Ups22AlarmEntry ::= SEQUENCE {
|
|
ups22AlarmId PositiveInteger,
|
|
ups22AlarmDescr AutonomousType,
|
|
ups22AlarmTime TimeStamp
|
|
}
|
|
|
|
ups22AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups22AlarmEntry 1 }
|
|
|
|
ups22AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups22AlarmEntry 2 }
|
|
|
|
ups22AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups22AlarmTime shall equal
|
|
0."
|
|
::= { ups22AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups22WellKnownAlarms OBJECT IDENTIFIER ::= { ups22Alarm 3 }
|
|
ups22AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups22WellKnownAlarms 1 }
|
|
|
|
ups22AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups22WellKnownAlarms 2 }
|
|
|
|
ups22AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups22ConfigLowBattTime."
|
|
::= { ups22WellKnownAlarms 3 }
|
|
|
|
|
|
ups22AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups22WellKnownAlarms 4 }
|
|
|
|
ups22AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups22WellKnownAlarms 5 }
|
|
|
|
ups22AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups22WellKnownAlarms 6 }
|
|
|
|
ups22AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups22WellKnownAlarms 7 }
|
|
|
|
ups22AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups22WellKnownAlarms 8 }
|
|
|
|
ups22AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups22WellKnownAlarms 9 }
|
|
|
|
ups22AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups22WellKnownAlarms 10 }
|
|
|
|
ups22AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups22WellKnownAlarms 11 }
|
|
|
|
ups22AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups22WellKnownAlarms 12 }
|
|
|
|
ups22AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups22WellKnownAlarms 13 }
|
|
|
|
ups22AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups22WellKnownAlarms 14 }
|
|
|
|
ups22AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups22WellKnownAlarms 15 }
|
|
|
|
ups22AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups22WellKnownAlarms 16 }
|
|
|
|
ups22AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups22WellKnownAlarms 17 }
|
|
|
|
ups22AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups22WellKnownAlarms 18 }
|
|
|
|
ups22AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups22WellKnownAlarms 19 }
|
|
|
|
ups22AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups22WellKnownAlarms 20 }
|
|
|
|
ups22AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups22WellKnownAlarms 21 }
|
|
|
|
ups22AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups22ShutdownAfterDelay countdown is underway."
|
|
::= { ups22WellKnownAlarms 22 }
|
|
|
|
ups22AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups22WellKnownAlarms 23 }
|
|
|
|
ups22AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups22WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups22Test OBJECT IDENTIFIER ::= { ups22Objects 7 }
|
|
|
|
ups22TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups22TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups22TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups22TestId variable to
|
|
ups22TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups22TestNoTestsInitiated is returned."
|
|
::= { ups22Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups22TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups22TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups22TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups22TestResultsSummary */
|
|
get (upsTestSpinLock, ups22TestResultsSummary,
|
|
ups22TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups22TestResultsSummary,
|
|
ups22TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups22TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups22TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups22Test 2 }
|
|
|
|
ups22TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups22TestId to ups22TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups22Test 3 }
|
|
|
|
ups22TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups22TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups22Test 4 }
|
|
|
|
ups22TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups22TestResultsSummary is noTestsInitiated(6),
|
|
ups22TestStartTime has the value 0."
|
|
::= { ups22Test 5 }
|
|
|
|
ups22TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups22TestResultsSummary is noTestsInitiated(6),
|
|
ups22TestElapsedTime has the value 0."
|
|
::= { ups22Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups22WellKnownTests OBJECT IDENTIFIER ::= { ups22Test 7 }
|
|
|
|
|
|
ups22TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups22WellKnownTests 1 }
|
|
|
|
ups22TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups22WellKnownTests 2 }
|
|
|
|
ups22TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups22WellKnownTests 3 }
|
|
|
|
ups22TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups22WellKnownTests 4 }
|
|
|
|
ups22TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups22WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups22Control OBJECT IDENTIFIER ::= { ups22Objects 8 }
|
|
|
|
ups22ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups22ShutdownAfterDelay and ups22RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups22Control 1 }
|
|
|
|
ups22ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups22ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups22ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups22ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups22ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups22ShutdownAfterDelay already in effect."
|
|
::= { ups22Control 2 }
|
|
|
|
ups22StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups22StartupAfterDelay
|
|
countdown or ups22RebootWithDuration countdown in
|
|
progress. When read, ups22StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups22Control 3 }
|
|
|
|
ups22RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups22ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups22RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups22Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups22Traps OBJECT IDENTIFIER ::= { upsModule22 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups22TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups22EstimatedMinutesRemaining, ups22SecondsOnBattery,
|
|
ups22ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups22Traps 1 }
|
|
|
|
ups22TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups22TestId, ups22TestSpinLock,
|
|
ups22TestResultsSummary, ups22TestResultsDetail,
|
|
ups22TestStartTime, ups22TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups22Traps 2 }
|
|
|
|
ups22TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups22AlarmId, ups22AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups22AlarmOnBattery and
|
|
ups22AlarmTestInProgress."
|
|
::= { ups22Traps 3 }
|
|
|
|
ups22TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups22AlarmId, ups22AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups22AlarmTestInProgress."
|
|
::= { ups22Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups22Conformance OBJECT IDENTIFIER ::= { upsModule22 3 }
|
|
|
|
ups22Compliances OBJECT IDENTIFIER ::= { ups22Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups22SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups22SubsetIdentGroup,
|
|
ups22SubsetBatteryGroup, ups22SubsetInputGroup,
|
|
ups22SubsetOutputGroup, ups22SubsetAlarmGroup,
|
|
ups22SubsetControlGroup }
|
|
|
|
OBJECT ups22BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups22AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups22AlarmOnBattery, ups22AlarmLowBattery,
|
|
ups22AlarmInputBad, ups22AlarmUpsOutputOff,
|
|
ups22AlarmUpsSystemOff, and ups22AlarmTestInProgress."
|
|
|
|
OBJECT ups22OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups22ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups22Compliances 1 }
|
|
|
|
ups22BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups22BasicIdentGroup,
|
|
ups22BasicBatteryGroup, ups22BasicInputGroup,
|
|
ups22BasicOutputGroup, ups22BasicAlarmGroup,
|
|
ups22BasicTestGroup, ups22BasicControlGroup }
|
|
|
|
OBJECT ups22AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups22AlarmOnBattery, ups22AlarmLowBattery,
|
|
ups22AlarmDepletedBattery, ups22AlarmTempBad,
|
|
ups22AlarmInputBad, ups22AlarmOutputOverload,
|
|
ups22AlarmOnBypass, ups22AlarmBypassBad,
|
|
ups22AlarmOutputOffAsRequested,
|
|
ups22AlarmUpsOffAsRequested, ups22AlarmUpsOutputOff,
|
|
ups22AlarmUpsSystemOff, ups22AlarmGeneralFault,
|
|
ups22AlarmDiagnosticTestFailed,
|
|
ups22AlarmCommunicationsLost, ups22AlarmShutdownPending,
|
|
and ups22AlarmTestInProgress."
|
|
|
|
OBJECT ups22TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups22TestNoTestsInitiated."
|
|
|
|
OBJECT ups22OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups22BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups22BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups22ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups22Compliances 2 }
|
|
|
|
ups22FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups22FullIdentGroup, ups22FullBatteryGroup,
|
|
ups22FullInputGroup, ups22FullOutputGroup,
|
|
ups22FullAlarmGroup, ups22FullTestGroup,
|
|
ups22FullControlGroup }
|
|
|
|
OBJECT ups22AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups22AlarmBatteryBad, ups22AlarmOnBattery,
|
|
ups22AlarmLowBattery, ups22AlarmDepletedBattery,
|
|
ups22AlarmTempBad, ups22AlarmInputBad, ups22AlarmOnBypass,
|
|
ups22AlarmBypassBad, ups22AlarmOutputOffAsRequested,
|
|
ups22AlarmUpsOffAsRequested, ups22AlarmUpsOutputOff,
|
|
ups22AlarmUpsSystemOff, ups22AlarmGeneralFault,
|
|
ups22AlarmDiagnosticTestFailed,
|
|
ups22AlarmCommunicationsLost, ups22AlarmShutdownPending,
|
|
and ups22AlarmTestInProgress."
|
|
|
|
OBJECT ups22TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups22TestNoTestsInitiated,
|
|
ups22TestGeneralSystemsTest, and
|
|
ups22TestQuickBatteryTest."
|
|
|
|
OBJECT ups22OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups22FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups22FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups22ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups22Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups22Groups OBJECT IDENTIFIER ::= { ups22Conformance 2 }
|
|
|
|
ups22SubsetGroups OBJECT IDENTIFIER ::= { ups22Groups 1 }
|
|
|
|
ups22SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups22IdentManufacturer, ups22IdentModel,
|
|
ups22IdentAgentSoftwareVersion, ups22IdentName,
|
|
ups22IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups22SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups22SubsetGroups 1 }
|
|
|
|
ups22SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups22BatteryStatus, ups22SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups22SubsetGroups 2 }
|
|
|
|
ups22SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups22InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups22SubsetGroups 3 }
|
|
|
|
ups22SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups22OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups22SubsetGroups 4 }
|
|
|
|
|
|
-- { ups22SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups22SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups22AlarmsPresent, ups22AlarmDescr, ups22AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups22SubsetGroups 6 }
|
|
|
|
-- { ups22SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups22SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups22ShutdownType, ups22ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups22SubsetGroups 8 }
|
|
|
|
ups22BasicGroups OBJECT IDENTIFIER ::= { ups22Groups 2 }
|
|
|
|
ups22BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups22IdentManufacturer, ups22IdentModel,
|
|
ups22IdentUPSSoftwareVersion,
|
|
ups22IdentAgentSoftwareVersion, ups22IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 1 }
|
|
|
|
ups22BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups22BatteryStatus, ups22SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 2 }
|
|
|
|
ups22BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups22InputLineBads, ups22InputNumLines,
|
|
ups22InputFrequency, ups22InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 3 }
|
|
|
|
ups22BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups22OutputSource, ups22OutputFrequency,
|
|
ups22OutputNumLines, ups22OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 4 }
|
|
|
|
ups22BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups22BypassFrequency, ups22BypassNumLines,
|
|
ups22BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 5 }
|
|
|
|
ups22BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups22AlarmsPresent, ups22AlarmDescr, ups22AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups22BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 6 }
|
|
|
|
ups22BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups22TestId, ups22TestSpinLock,
|
|
ups22TestResultsSummary, ups22TestResultsDetail,
|
|
ups22TestStartTime, ups22TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 7 }
|
|
|
|
ups22BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups22ShutdownType, ups22ShutdownAfterDelay,
|
|
ups22StartupAfterDelay, ups22RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups22BasicGroups 8 }
|
|
|
|
ups22FullGroups OBJECT IDENTIFIER ::= { ups22Groups 3 }
|
|
|
|
ups22FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups22IdentManufacturer, ups22IdentModel,
|
|
ups22IdentUPSSoftwareVersion,
|
|
ups22IdentAgentSoftwareVersion, ups22IdentName,
|
|
ups22IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups22FullGroups 1 }
|
|
|
|
ups22FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups22BatteryStatus, ups22SecondsOnBattery,
|
|
ups22EstimatedMinutesRemaining,
|
|
ups22EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 2 }
|
|
|
|
ups22FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups22InputLineBads, ups22InputNumLines,
|
|
ups22InputFrequency, ups22InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 3 }
|
|
|
|
ups22FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups22OutputSource, ups22OutputFrequency,
|
|
ups22OutputNumLines, ups22OutputVoltage,
|
|
ups22OutputCurrent, ups22OutputPower,
|
|
ups22OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 4 }
|
|
|
|
ups22FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups22BypassFrequency, ups22BypassNumLines,
|
|
ups22BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 5 }
|
|
|
|
ups22FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups22AlarmsPresent, ups22AlarmDescr, ups22AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups22FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 6 }
|
|
|
|
ups22FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups22TestId, ups22TestSpinLock,
|
|
ups22TestResultsSummary, ups22TestResultsDetail,
|
|
ups22TestStartTime, ups22TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 7 }
|
|
|
|
ups22FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups22ShutdownType, ups22ShutdownAfterDelay,
|
|
ups22StartupAfterDelay, ups22RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups22FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups22FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 23 data
|
|
--
|
|
|
|
upsModule23 OBJECT IDENTIFIER ::= { upsModular 24 }
|
|
ups23Objects OBJECT IDENTIFIER ::= { upsModule23 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups23IdentName and
|
|
-- ups23IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups23Ident OBJECT IDENTIFIER ::= { ups23Objects 1 }
|
|
|
|
ups23IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups23Ident 1 }
|
|
|
|
ups23IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups23Ident 2 }
|
|
|
|
ups23IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups23IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups23Ident 3 }
|
|
|
|
ups23IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups23IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups23Ident 4 }
|
|
|
|
ups23IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups23Ident 5 }
|
|
|
|
ups23IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups23Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups23Battery OBJECT IDENTIFIER ::= { ups23Objects 2 }
|
|
|
|
ups23BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups23ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups23ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups23Battery 1 }
|
|
|
|
ups23SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups23Battery 2 }
|
|
|
|
ups23EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups23Battery 3 }
|
|
|
|
ups23EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups23Battery 4 }
|
|
|
|
ups23BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups23Battery 5 }
|
|
|
|
ups23BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups23Battery 6 }
|
|
|
|
ups23BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups23Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups23Input OBJECT IDENTIFIER ::= { ups23Objects 3 }
|
|
|
|
ups23InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups23Input 1 }
|
|
|
|
|
|
ups23InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups23Input 2 }
|
|
|
|
ups23InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups23InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups23InputNumLines."
|
|
::= { ups23Input 3 }
|
|
|
|
ups23InputEntry OBJECT-TYPE
|
|
SYNTAX Ups23InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups23InputLineIndex }
|
|
::= { ups23InputTable 1 }
|
|
|
|
Ups23InputEntry ::= SEQUENCE {
|
|
ups23InputLineIndex PositiveInteger,
|
|
ups23InputFrequency NonNegativeInteger,
|
|
ups23InputVoltage NonNegativeInteger,
|
|
ups23InputCurrent NonNegativeInteger,
|
|
ups23InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups23InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups23InputEntry 1 }
|
|
|
|
ups23InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups23InputEntry 2 }
|
|
|
|
ups23InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups23InputEntry 3 }
|
|
|
|
ups23InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups23InputEntry 4 }
|
|
|
|
ups23InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups23InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups23Output OBJECT IDENTIFIER ::= { ups23Objects 4 }
|
|
|
|
ups23OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups23Output 1 }
|
|
|
|
ups23OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups23Output 2 }
|
|
|
|
ups23OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups23Output 3 }
|
|
|
|
ups23OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups23OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups23OutputNumLines."
|
|
::= { ups23Output 4 }
|
|
|
|
ups23OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups23OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups23OutputLineIndex }
|
|
::= { ups23OutputTable 1 }
|
|
|
|
Ups23OutputEntry ::= SEQUENCE {
|
|
ups23OutputLineIndex PositiveInteger,
|
|
ups23OutputVoltage NonNegativeInteger,
|
|
ups23OutputCurrent NonNegativeInteger,
|
|
ups23OutputPower NonNegativeInteger,
|
|
ups23OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups23OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups23OutputEntry 1 }
|
|
|
|
ups23OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups23OutputEntry 2 }
|
|
|
|
ups23OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups23OutputEntry 3 }
|
|
|
|
ups23OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups23OutputEntry 4 }
|
|
|
|
ups23OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups23OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups23Bypass OBJECT IDENTIFIER ::= { ups23Objects 5 }
|
|
|
|
ups23BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups23Bypass 1 }
|
|
|
|
ups23BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups23Bypass 2 }
|
|
|
|
ups23BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups23BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups23BypassNumLines."
|
|
::= { ups23Bypass 3 }
|
|
|
|
ups23BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups23BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups23BypassLineIndex }
|
|
::= { ups23BypassTable 1 }
|
|
|
|
Ups23BypassEntry ::= SEQUENCE {
|
|
ups23BypassLineIndex PositiveInteger,
|
|
ups23BypassVoltage NonNegativeInteger,
|
|
ups23BypassCurrent NonNegativeInteger,
|
|
ups23BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups23BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups23BypassEntry 1 }
|
|
|
|
ups23BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups23BypassEntry 2 }
|
|
|
|
ups23BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups23BypassEntry 3 }
|
|
|
|
ups23BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups23BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups23Alarm OBJECT IDENTIFIER ::= { ups23Objects 6 }
|
|
|
|
ups23AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups23Alarm 1 }
|
|
|
|
ups23AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups23AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups23AlarmId equal to 1, and increments the value of
|
|
ups23AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups23AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups23AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups23AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups23AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups23AlarmsPresent."
|
|
::= { ups23Alarm 2 }
|
|
|
|
ups23AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups23AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups23AlarmId }
|
|
::= { ups23AlarmTable 1 }
|
|
|
|
Ups23AlarmEntry ::= SEQUENCE {
|
|
ups23AlarmId PositiveInteger,
|
|
ups23AlarmDescr AutonomousType,
|
|
ups23AlarmTime TimeStamp
|
|
}
|
|
|
|
ups23AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups23AlarmEntry 1 }
|
|
|
|
ups23AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups23AlarmEntry 2 }
|
|
|
|
ups23AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups23AlarmTime shall equal
|
|
0."
|
|
::= { ups23AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups23WellKnownAlarms OBJECT IDENTIFIER ::= { ups23Alarm 3 }
|
|
ups23AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups23WellKnownAlarms 1 }
|
|
|
|
ups23AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups23WellKnownAlarms 2 }
|
|
|
|
ups23AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups23ConfigLowBattTime."
|
|
::= { ups23WellKnownAlarms 3 }
|
|
|
|
|
|
ups23AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups23WellKnownAlarms 4 }
|
|
|
|
ups23AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups23WellKnownAlarms 5 }
|
|
|
|
ups23AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups23WellKnownAlarms 6 }
|
|
|
|
ups23AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups23WellKnownAlarms 7 }
|
|
|
|
ups23AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups23WellKnownAlarms 8 }
|
|
|
|
ups23AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups23WellKnownAlarms 9 }
|
|
|
|
ups23AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups23WellKnownAlarms 10 }
|
|
|
|
ups23AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups23WellKnownAlarms 11 }
|
|
|
|
ups23AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups23WellKnownAlarms 12 }
|
|
|
|
ups23AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups23WellKnownAlarms 13 }
|
|
|
|
ups23AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups23WellKnownAlarms 14 }
|
|
|
|
ups23AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups23WellKnownAlarms 15 }
|
|
|
|
ups23AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups23WellKnownAlarms 16 }
|
|
|
|
ups23AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups23WellKnownAlarms 17 }
|
|
|
|
ups23AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups23WellKnownAlarms 18 }
|
|
|
|
ups23AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups23WellKnownAlarms 19 }
|
|
|
|
ups23AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups23WellKnownAlarms 20 }
|
|
|
|
ups23AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups23WellKnownAlarms 21 }
|
|
|
|
ups23AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups23ShutdownAfterDelay countdown is underway."
|
|
::= { ups23WellKnownAlarms 22 }
|
|
|
|
ups23AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups23WellKnownAlarms 23 }
|
|
|
|
ups23AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups23WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups23Test OBJECT IDENTIFIER ::= { ups23Objects 7 }
|
|
|
|
ups23TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups23TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups23TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups23TestId variable to
|
|
ups23TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups23TestNoTestsInitiated is returned."
|
|
::= { ups23Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups23TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups23TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups23TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups23TestResultsSummary */
|
|
get (upsTestSpinLock, ups23TestResultsSummary,
|
|
ups23TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups23TestResultsSummary,
|
|
ups23TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups23TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups23TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups23Test 2 }
|
|
|
|
ups23TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups23TestId to ups23TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups23Test 3 }
|
|
|
|
ups23TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups23TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups23Test 4 }
|
|
|
|
ups23TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups23TestResultsSummary is noTestsInitiated(6),
|
|
ups23TestStartTime has the value 0."
|
|
::= { ups23Test 5 }
|
|
|
|
ups23TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups23TestResultsSummary is noTestsInitiated(6),
|
|
ups23TestElapsedTime has the value 0."
|
|
::= { ups23Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups23WellKnownTests OBJECT IDENTIFIER ::= { ups23Test 7 }
|
|
|
|
|
|
ups23TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups23WellKnownTests 1 }
|
|
|
|
ups23TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups23WellKnownTests 2 }
|
|
|
|
ups23TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups23WellKnownTests 3 }
|
|
|
|
ups23TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups23WellKnownTests 4 }
|
|
|
|
ups23TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups23WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups23Control OBJECT IDENTIFIER ::= { ups23Objects 8 }
|
|
|
|
ups23ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups23ShutdownAfterDelay and ups23RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups23Control 1 }
|
|
|
|
ups23ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups23ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups23ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups23ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups23ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups23ShutdownAfterDelay already in effect."
|
|
::= { ups23Control 2 }
|
|
|
|
ups23StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups23StartupAfterDelay
|
|
countdown or ups23RebootWithDuration countdown in
|
|
progress. When read, ups23StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups23Control 3 }
|
|
|
|
ups23RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups23ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups23RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups23Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups23Traps OBJECT IDENTIFIER ::= { upsModule23 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups23TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups23EstimatedMinutesRemaining, ups23SecondsOnBattery,
|
|
ups23ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups23Traps 1 }
|
|
|
|
ups23TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups23TestId, ups23TestSpinLock,
|
|
ups23TestResultsSummary, ups23TestResultsDetail,
|
|
ups23TestStartTime, ups23TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups23Traps 2 }
|
|
|
|
ups23TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups23AlarmId, ups23AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups23AlarmOnBattery and
|
|
ups23AlarmTestInProgress."
|
|
::= { ups23Traps 3 }
|
|
|
|
ups23TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups23AlarmId, ups23AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups23AlarmTestInProgress."
|
|
::= { ups23Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups23Conformance OBJECT IDENTIFIER ::= { upsModule23 3 }
|
|
|
|
ups23Compliances OBJECT IDENTIFIER ::= { ups23Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups23SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups23SubsetIdentGroup,
|
|
ups23SubsetBatteryGroup, ups23SubsetInputGroup,
|
|
ups23SubsetOutputGroup, ups23SubsetAlarmGroup,
|
|
ups23SubsetControlGroup }
|
|
|
|
OBJECT ups23BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups23AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups23AlarmOnBattery, ups23AlarmLowBattery,
|
|
ups23AlarmInputBad, ups23AlarmUpsOutputOff,
|
|
ups23AlarmUpsSystemOff, and ups23AlarmTestInProgress."
|
|
|
|
OBJECT ups23OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups23ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups23Compliances 1 }
|
|
|
|
ups23BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups23BasicIdentGroup,
|
|
ups23BasicBatteryGroup, ups23BasicInputGroup,
|
|
ups23BasicOutputGroup, ups23BasicAlarmGroup,
|
|
ups23BasicTestGroup, ups23BasicControlGroup }
|
|
|
|
OBJECT ups23AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups23AlarmOnBattery, ups23AlarmLowBattery,
|
|
ups23AlarmDepletedBattery, ups23AlarmTempBad,
|
|
ups23AlarmInputBad, ups23AlarmOutputOverload,
|
|
ups23AlarmOnBypass, ups23AlarmBypassBad,
|
|
ups23AlarmOutputOffAsRequested,
|
|
ups23AlarmUpsOffAsRequested, ups23AlarmUpsOutputOff,
|
|
ups23AlarmUpsSystemOff, ups23AlarmGeneralFault,
|
|
ups23AlarmDiagnosticTestFailed,
|
|
ups23AlarmCommunicationsLost, ups23AlarmShutdownPending,
|
|
and ups23AlarmTestInProgress."
|
|
|
|
OBJECT ups23TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups23TestNoTestsInitiated."
|
|
|
|
OBJECT ups23OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups23BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups23BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups23ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups23Compliances 2 }
|
|
|
|
ups23FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups23FullIdentGroup, ups23FullBatteryGroup,
|
|
ups23FullInputGroup, ups23FullOutputGroup,
|
|
ups23FullAlarmGroup, ups23FullTestGroup,
|
|
ups23FullControlGroup }
|
|
|
|
OBJECT ups23AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups23AlarmBatteryBad, ups23AlarmOnBattery,
|
|
ups23AlarmLowBattery, ups23AlarmDepletedBattery,
|
|
ups23AlarmTempBad, ups23AlarmInputBad, ups23AlarmOnBypass,
|
|
ups23AlarmBypassBad, ups23AlarmOutputOffAsRequested,
|
|
ups23AlarmUpsOffAsRequested, ups23AlarmUpsOutputOff,
|
|
ups23AlarmUpsSystemOff, ups23AlarmGeneralFault,
|
|
ups23AlarmDiagnosticTestFailed,
|
|
ups23AlarmCommunicationsLost, ups23AlarmShutdownPending,
|
|
and ups23AlarmTestInProgress."
|
|
|
|
OBJECT ups23TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups23TestNoTestsInitiated,
|
|
ups23TestGeneralSystemsTest, and
|
|
ups23TestQuickBatteryTest."
|
|
|
|
OBJECT ups23OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups23FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups23FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups23ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups23Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups23Groups OBJECT IDENTIFIER ::= { ups23Conformance 2 }
|
|
|
|
ups23SubsetGroups OBJECT IDENTIFIER ::= { ups23Groups 1 }
|
|
|
|
ups23SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups23IdentManufacturer, ups23IdentModel,
|
|
ups23IdentAgentSoftwareVersion, ups23IdentName,
|
|
ups23IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups23SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups23SubsetGroups 1 }
|
|
|
|
ups23SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups23BatteryStatus, ups23SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups23SubsetGroups 2 }
|
|
|
|
ups23SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups23InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups23SubsetGroups 3 }
|
|
|
|
ups23SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups23OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups23SubsetGroups 4 }
|
|
|
|
|
|
-- { ups23SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups23SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups23AlarmsPresent, ups23AlarmDescr, ups23AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups23SubsetGroups 6 }
|
|
|
|
-- { ups23SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups23SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups23ShutdownType, ups23ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups23SubsetGroups 8 }
|
|
|
|
ups23BasicGroups OBJECT IDENTIFIER ::= { ups23Groups 2 }
|
|
|
|
ups23BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups23IdentManufacturer, ups23IdentModel,
|
|
ups23IdentUPSSoftwareVersion,
|
|
ups23IdentAgentSoftwareVersion, ups23IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 1 }
|
|
|
|
ups23BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups23BatteryStatus, ups23SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 2 }
|
|
|
|
ups23BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups23InputLineBads, ups23InputNumLines,
|
|
ups23InputFrequency, ups23InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 3 }
|
|
|
|
ups23BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups23OutputSource, ups23OutputFrequency,
|
|
ups23OutputNumLines, ups23OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 4 }
|
|
|
|
ups23BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups23BypassFrequency, ups23BypassNumLines,
|
|
ups23BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 5 }
|
|
|
|
ups23BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups23AlarmsPresent, ups23AlarmDescr, ups23AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups23BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 6 }
|
|
|
|
ups23BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups23TestId, ups23TestSpinLock,
|
|
ups23TestResultsSummary, ups23TestResultsDetail,
|
|
ups23TestStartTime, ups23TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 7 }
|
|
|
|
ups23BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups23ShutdownType, ups23ShutdownAfterDelay,
|
|
ups23StartupAfterDelay, ups23RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups23BasicGroups 8 }
|
|
|
|
ups23FullGroups OBJECT IDENTIFIER ::= { ups23Groups 3 }
|
|
|
|
ups23FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups23IdentManufacturer, ups23IdentModel,
|
|
ups23IdentUPSSoftwareVersion,
|
|
ups23IdentAgentSoftwareVersion, ups23IdentName,
|
|
ups23IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups23FullGroups 1 }
|
|
|
|
ups23FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups23BatteryStatus, ups23SecondsOnBattery,
|
|
ups23EstimatedMinutesRemaining,
|
|
ups23EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 2 }
|
|
|
|
ups23FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups23InputLineBads, ups23InputNumLines,
|
|
ups23InputFrequency, ups23InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 3 }
|
|
|
|
ups23FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups23OutputSource, ups23OutputFrequency,
|
|
ups23OutputNumLines, ups23OutputVoltage,
|
|
ups23OutputCurrent, ups23OutputPower,
|
|
ups23OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 4 }
|
|
|
|
ups23FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups23BypassFrequency, ups23BypassNumLines,
|
|
ups23BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 5 }
|
|
|
|
ups23FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups23AlarmsPresent, ups23AlarmDescr, ups23AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups23FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 6 }
|
|
|
|
ups23FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups23TestId, ups23TestSpinLock,
|
|
ups23TestResultsSummary, ups23TestResultsDetail,
|
|
ups23TestStartTime, ups23TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 7 }
|
|
|
|
ups23FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups23ShutdownType, ups23ShutdownAfterDelay,
|
|
ups23StartupAfterDelay, ups23RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups23FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups23FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 24 data
|
|
--
|
|
|
|
upsModule24 OBJECT IDENTIFIER ::= { upsModular 25 }
|
|
ups24Objects OBJECT IDENTIFIER ::= { upsModule24 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups24IdentName and
|
|
-- ups24IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups24Ident OBJECT IDENTIFIER ::= { ups24Objects 1 }
|
|
|
|
ups24IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups24Ident 1 }
|
|
|
|
ups24IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups24Ident 2 }
|
|
|
|
ups24IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups24IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups24Ident 3 }
|
|
|
|
ups24IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups24IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups24Ident 4 }
|
|
|
|
ups24IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups24Ident 5 }
|
|
|
|
ups24IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups24Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups24Battery OBJECT IDENTIFIER ::= { ups24Objects 2 }
|
|
|
|
ups24BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups24ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups24ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups24Battery 1 }
|
|
|
|
ups24SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups24Battery 2 }
|
|
|
|
ups24EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups24Battery 3 }
|
|
|
|
ups24EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups24Battery 4 }
|
|
|
|
ups24BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups24Battery 5 }
|
|
|
|
ups24BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups24Battery 6 }
|
|
|
|
ups24BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups24Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups24Input OBJECT IDENTIFIER ::= { ups24Objects 3 }
|
|
|
|
ups24InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups24Input 1 }
|
|
|
|
|
|
ups24InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups24Input 2 }
|
|
|
|
ups24InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups24InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups24InputNumLines."
|
|
::= { ups24Input 3 }
|
|
|
|
ups24InputEntry OBJECT-TYPE
|
|
SYNTAX Ups24InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups24InputLineIndex }
|
|
::= { ups24InputTable 1 }
|
|
|
|
Ups24InputEntry ::= SEQUENCE {
|
|
ups24InputLineIndex PositiveInteger,
|
|
ups24InputFrequency NonNegativeInteger,
|
|
ups24InputVoltage NonNegativeInteger,
|
|
ups24InputCurrent NonNegativeInteger,
|
|
ups24InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups24InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups24InputEntry 1 }
|
|
|
|
ups24InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups24InputEntry 2 }
|
|
|
|
ups24InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups24InputEntry 3 }
|
|
|
|
ups24InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups24InputEntry 4 }
|
|
|
|
ups24InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups24InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups24Output OBJECT IDENTIFIER ::= { ups24Objects 4 }
|
|
|
|
ups24OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups24Output 1 }
|
|
|
|
ups24OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups24Output 2 }
|
|
|
|
ups24OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups24Output 3 }
|
|
|
|
ups24OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups24OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups24OutputNumLines."
|
|
::= { ups24Output 4 }
|
|
|
|
ups24OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups24OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups24OutputLineIndex }
|
|
::= { ups24OutputTable 1 }
|
|
|
|
Ups24OutputEntry ::= SEQUENCE {
|
|
ups24OutputLineIndex PositiveInteger,
|
|
ups24OutputVoltage NonNegativeInteger,
|
|
ups24OutputCurrent NonNegativeInteger,
|
|
ups24OutputPower NonNegativeInteger,
|
|
ups24OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups24OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups24OutputEntry 1 }
|
|
|
|
ups24OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups24OutputEntry 2 }
|
|
|
|
ups24OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups24OutputEntry 3 }
|
|
|
|
ups24OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups24OutputEntry 4 }
|
|
|
|
ups24OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups24OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups24Bypass OBJECT IDENTIFIER ::= { ups24Objects 5 }
|
|
|
|
ups24BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups24Bypass 1 }
|
|
|
|
ups24BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups24Bypass 2 }
|
|
|
|
ups24BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups24BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups24BypassNumLines."
|
|
::= { ups24Bypass 3 }
|
|
|
|
ups24BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups24BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups24BypassLineIndex }
|
|
::= { ups24BypassTable 1 }
|
|
|
|
Ups24BypassEntry ::= SEQUENCE {
|
|
ups24BypassLineIndex PositiveInteger,
|
|
ups24BypassVoltage NonNegativeInteger,
|
|
ups24BypassCurrent NonNegativeInteger,
|
|
ups24BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups24BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups24BypassEntry 1 }
|
|
|
|
ups24BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups24BypassEntry 2 }
|
|
|
|
ups24BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups24BypassEntry 3 }
|
|
|
|
ups24BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups24BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups24Alarm OBJECT IDENTIFIER ::= { ups24Objects 6 }
|
|
|
|
ups24AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups24Alarm 1 }
|
|
|
|
ups24AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups24AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups24AlarmId equal to 1, and increments the value of
|
|
ups24AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups24AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups24AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups24AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups24AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups24AlarmsPresent."
|
|
::= { ups24Alarm 2 }
|
|
|
|
ups24AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups24AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups24AlarmId }
|
|
::= { ups24AlarmTable 1 }
|
|
|
|
Ups24AlarmEntry ::= SEQUENCE {
|
|
ups24AlarmId PositiveInteger,
|
|
ups24AlarmDescr AutonomousType,
|
|
ups24AlarmTime TimeStamp
|
|
}
|
|
|
|
ups24AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups24AlarmEntry 1 }
|
|
|
|
ups24AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups24AlarmEntry 2 }
|
|
|
|
ups24AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups24AlarmTime shall equal
|
|
0."
|
|
::= { ups24AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups24WellKnownAlarms OBJECT IDENTIFIER ::= { ups24Alarm 3 }
|
|
ups24AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups24WellKnownAlarms 1 }
|
|
|
|
ups24AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups24WellKnownAlarms 2 }
|
|
|
|
ups24AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups24ConfigLowBattTime."
|
|
::= { ups24WellKnownAlarms 3 }
|
|
|
|
|
|
ups24AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups24WellKnownAlarms 4 }
|
|
|
|
ups24AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups24WellKnownAlarms 5 }
|
|
|
|
ups24AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups24WellKnownAlarms 6 }
|
|
|
|
ups24AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups24WellKnownAlarms 7 }
|
|
|
|
ups24AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups24WellKnownAlarms 8 }
|
|
|
|
ups24AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups24WellKnownAlarms 9 }
|
|
|
|
ups24AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups24WellKnownAlarms 10 }
|
|
|
|
ups24AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups24WellKnownAlarms 11 }
|
|
|
|
ups24AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups24WellKnownAlarms 12 }
|
|
|
|
ups24AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups24WellKnownAlarms 13 }
|
|
|
|
ups24AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups24WellKnownAlarms 14 }
|
|
|
|
ups24AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups24WellKnownAlarms 15 }
|
|
|
|
ups24AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups24WellKnownAlarms 16 }
|
|
|
|
ups24AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups24WellKnownAlarms 17 }
|
|
|
|
ups24AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups24WellKnownAlarms 18 }
|
|
|
|
ups24AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups24WellKnownAlarms 19 }
|
|
|
|
ups24AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups24WellKnownAlarms 20 }
|
|
|
|
ups24AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups24WellKnownAlarms 21 }
|
|
|
|
ups24AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups24ShutdownAfterDelay countdown is underway."
|
|
::= { ups24WellKnownAlarms 22 }
|
|
|
|
ups24AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups24WellKnownAlarms 23 }
|
|
|
|
ups24AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups24WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups24Test OBJECT IDENTIFIER ::= { ups24Objects 7 }
|
|
|
|
ups24TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups24TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups24TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups24TestId variable to
|
|
ups24TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups24TestNoTestsInitiated is returned."
|
|
::= { ups24Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups24TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups24TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups24TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups24TestResultsSummary */
|
|
get (upsTestSpinLock, ups24TestResultsSummary,
|
|
ups24TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups24TestResultsSummary,
|
|
ups24TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups24TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups24TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups24Test 2 }
|
|
|
|
ups24TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups24TestId to ups24TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups24Test 3 }
|
|
|
|
ups24TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups24TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups24Test 4 }
|
|
|
|
ups24TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups24TestResultsSummary is noTestsInitiated(6),
|
|
ups24TestStartTime has the value 0."
|
|
::= { ups24Test 5 }
|
|
|
|
ups24TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups24TestResultsSummary is noTestsInitiated(6),
|
|
ups24TestElapsedTime has the value 0."
|
|
::= { ups24Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups24WellKnownTests OBJECT IDENTIFIER ::= { ups24Test 7 }
|
|
|
|
|
|
ups24TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups24WellKnownTests 1 }
|
|
|
|
ups24TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups24WellKnownTests 2 }
|
|
|
|
ups24TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups24WellKnownTests 3 }
|
|
|
|
ups24TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups24WellKnownTests 4 }
|
|
|
|
ups24TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups24WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups24Control OBJECT IDENTIFIER ::= { ups24Objects 8 }
|
|
|
|
ups24ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups24ShutdownAfterDelay and ups24RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups24Control 1 }
|
|
|
|
ups24ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups24ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups24ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups24ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups24ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups24ShutdownAfterDelay already in effect."
|
|
::= { ups24Control 2 }
|
|
|
|
ups24StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups24StartupAfterDelay
|
|
countdown or ups24RebootWithDuration countdown in
|
|
progress. When read, ups24StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups24Control 3 }
|
|
|
|
ups24RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups24ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups24RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups24Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups24Traps OBJECT IDENTIFIER ::= { upsModule24 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups24TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups24EstimatedMinutesRemaining, ups24SecondsOnBattery,
|
|
ups24ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups24Traps 1 }
|
|
|
|
ups24TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups24TestId, ups24TestSpinLock,
|
|
ups24TestResultsSummary, ups24TestResultsDetail,
|
|
ups24TestStartTime, ups24TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups24Traps 2 }
|
|
|
|
ups24TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups24AlarmId, ups24AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups24AlarmOnBattery and
|
|
ups24AlarmTestInProgress."
|
|
::= { ups24Traps 3 }
|
|
|
|
ups24TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups24AlarmId, ups24AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups24AlarmTestInProgress."
|
|
::= { ups24Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups24Conformance OBJECT IDENTIFIER ::= { upsModule24 3 }
|
|
|
|
ups24Compliances OBJECT IDENTIFIER ::= { ups24Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups24SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups24SubsetIdentGroup,
|
|
ups24SubsetBatteryGroup, ups24SubsetInputGroup,
|
|
ups24SubsetOutputGroup, ups24SubsetAlarmGroup,
|
|
ups24SubsetControlGroup }
|
|
|
|
OBJECT ups24BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups24AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups24AlarmOnBattery, ups24AlarmLowBattery,
|
|
ups24AlarmInputBad, ups24AlarmUpsOutputOff,
|
|
ups24AlarmUpsSystemOff, and ups24AlarmTestInProgress."
|
|
|
|
OBJECT ups24OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups24ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups24Compliances 1 }
|
|
|
|
ups24BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups24BasicIdentGroup,
|
|
ups24BasicBatteryGroup, ups24BasicInputGroup,
|
|
ups24BasicOutputGroup, ups24BasicAlarmGroup,
|
|
ups24BasicTestGroup, ups24BasicControlGroup }
|
|
|
|
OBJECT ups24AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups24AlarmOnBattery, ups24AlarmLowBattery,
|
|
ups24AlarmDepletedBattery, ups24AlarmTempBad,
|
|
ups24AlarmInputBad, ups24AlarmOutputOverload,
|
|
ups24AlarmOnBypass, ups24AlarmBypassBad,
|
|
ups24AlarmOutputOffAsRequested,
|
|
ups24AlarmUpsOffAsRequested, ups24AlarmUpsOutputOff,
|
|
ups24AlarmUpsSystemOff, ups24AlarmGeneralFault,
|
|
ups24AlarmDiagnosticTestFailed,
|
|
ups24AlarmCommunicationsLost, ups24AlarmShutdownPending,
|
|
and ups24AlarmTestInProgress."
|
|
|
|
OBJECT ups24TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups24TestNoTestsInitiated."
|
|
|
|
OBJECT ups24OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups24BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups24BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups24ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
|
|
::= { ups24Compliances 2 }
|
|
|
|
ups24FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups24FullIdentGroup, ups24FullBatteryGroup,
|
|
ups24FullInputGroup, ups24FullOutputGroup,
|
|
ups24FullAlarmGroup, ups24FullTestGroup,
|
|
ups24FullControlGroup }
|
|
|
|
OBJECT ups24AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups24AlarmBatteryBad, ups24AlarmOnBattery,
|
|
ups24AlarmLowBattery, ups24AlarmDepletedBattery,
|
|
ups24AlarmTempBad, ups24AlarmInputBad, ups24AlarmOnBypass,
|
|
ups24AlarmBypassBad, ups24AlarmOutputOffAsRequested,
|
|
ups24AlarmUpsOffAsRequested, ups24AlarmUpsOutputOff,
|
|
ups24AlarmUpsSystemOff, ups24AlarmGeneralFault,
|
|
ups24AlarmDiagnosticTestFailed,
|
|
ups24AlarmCommunicationsLost, ups24AlarmShutdownPending,
|
|
and ups24AlarmTestInProgress."
|
|
|
|
OBJECT ups24TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups24TestNoTestsInitiated,
|
|
ups24TestGeneralSystemsTest, and
|
|
ups24TestQuickBatteryTest."
|
|
|
|
OBJECT ups24OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups24FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups24FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups24ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups24Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups24Groups OBJECT IDENTIFIER ::= { ups24Conformance 2 }
|
|
|
|
ups24SubsetGroups OBJECT IDENTIFIER ::= { ups24Groups 1 }
|
|
|
|
ups24SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups24IdentManufacturer, ups24IdentModel,
|
|
ups24IdentAgentSoftwareVersion, ups24IdentName,
|
|
ups24IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups24SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups24SubsetGroups 1 }
|
|
|
|
ups24SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups24BatteryStatus, ups24SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups24SubsetGroups 2 }
|
|
|
|
ups24SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups24InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups24SubsetGroups 3 }
|
|
|
|
ups24SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups24OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups24SubsetGroups 4 }
|
|
|
|
|
|
-- { ups24SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups24SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups24AlarmsPresent, ups24AlarmDescr, ups24AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups24SubsetGroups 6 }
|
|
|
|
-- { ups24SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups24SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups24ShutdownType, ups24ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups24SubsetGroups 8 }
|
|
|
|
ups24BasicGroups OBJECT IDENTIFIER ::= { ups24Groups 2 }
|
|
|
|
ups24BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups24IdentManufacturer, ups24IdentModel,
|
|
ups24IdentUPSSoftwareVersion,
|
|
ups24IdentAgentSoftwareVersion, ups24IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 1 }
|
|
|
|
ups24BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups24BatteryStatus, ups24SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 2 }
|
|
|
|
ups24BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups24InputLineBads, ups24InputNumLines,
|
|
ups24InputFrequency, ups24InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 3 }
|
|
|
|
ups24BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups24OutputSource, ups24OutputFrequency,
|
|
ups24OutputNumLines, ups24OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 4 }
|
|
|
|
ups24BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups24BypassFrequency, ups24BypassNumLines,
|
|
ups24BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 5 }
|
|
|
|
ups24BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups24AlarmsPresent, ups24AlarmDescr, ups24AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups24BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 6 }
|
|
|
|
ups24BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups24TestId, ups24TestSpinLock,
|
|
ups24TestResultsSummary, ups24TestResultsDetail,
|
|
ups24TestStartTime, ups24TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 7 }
|
|
|
|
ups24BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups24ShutdownType, ups24ShutdownAfterDelay,
|
|
ups24StartupAfterDelay, ups24RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups24BasicGroups 8 }
|
|
|
|
ups24FullGroups OBJECT IDENTIFIER ::= { ups24Groups 3 }
|
|
|
|
ups24FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups24IdentManufacturer, ups24IdentModel,
|
|
ups24IdentUPSSoftwareVersion,
|
|
ups24IdentAgentSoftwareVersion, ups24IdentName,
|
|
ups24IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups24FullGroups 1 }
|
|
|
|
ups24FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups24BatteryStatus, ups24SecondsOnBattery,
|
|
ups24EstimatedMinutesRemaining,
|
|
ups24EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 2 }
|
|
|
|
ups24FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups24InputLineBads, ups24InputNumLines,
|
|
ups24InputFrequency, ups24InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 3 }
|
|
|
|
ups24FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups24OutputSource, ups24OutputFrequency,
|
|
ups24OutputNumLines, ups24OutputVoltage,
|
|
ups24OutputCurrent, ups24OutputPower,
|
|
ups24OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 4 }
|
|
|
|
ups24FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups24BypassFrequency, ups24BypassNumLines,
|
|
ups24BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 5 }
|
|
|
|
ups24FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups24AlarmsPresent, ups24AlarmDescr, ups24AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups24FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 6 }
|
|
|
|
ups24FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups24TestId, ups24TestSpinLock,
|
|
ups24TestResultsSummary, ups24TestResultsDetail,
|
|
ups24TestStartTime, ups24TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 7 }
|
|
|
|
ups24FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups24ShutdownType, ups24ShutdownAfterDelay,
|
|
ups24StartupAfterDelay, ups24RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups24FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups24FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 25 data
|
|
--
|
|
|
|
upsModule25 OBJECT IDENTIFIER ::= { upsModular 26 }
|
|
ups25Objects OBJECT IDENTIFIER ::= { upsModule25 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups25IdentName and
|
|
-- ups25IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups25Ident OBJECT IDENTIFIER ::= { ups25Objects 1 }
|
|
|
|
ups25IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups25Ident 1 }
|
|
|
|
ups25IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups25Ident 2 }
|
|
|
|
ups25IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups25IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups25Ident 3 }
|
|
|
|
ups25IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups25IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups25Ident 4 }
|
|
|
|
ups25IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups25Ident 5 }
|
|
|
|
ups25IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups25Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups25Battery OBJECT IDENTIFIER ::= { ups25Objects 2 }
|
|
|
|
ups25BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups25ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups25ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups25Battery 1 }
|
|
|
|
ups25SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups25Battery 2 }
|
|
|
|
ups25EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups25Battery 3 }
|
|
|
|
ups25EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups25Battery 4 }
|
|
|
|
ups25BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups25Battery 5 }
|
|
|
|
ups25BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups25Battery 6 }
|
|
|
|
ups25BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups25Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups25Input OBJECT IDENTIFIER ::= { ups25Objects 3 }
|
|
|
|
ups25InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups25Input 1 }
|
|
|
|
|
|
ups25InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups25Input 2 }
|
|
|
|
ups25InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups25InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups25InputNumLines."
|
|
::= { ups25Input 3 }
|
|
|
|
ups25InputEntry OBJECT-TYPE
|
|
SYNTAX Ups25InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups25InputLineIndex }
|
|
::= { ups25InputTable 1 }
|
|
|
|
Ups25InputEntry ::= SEQUENCE {
|
|
ups25InputLineIndex PositiveInteger,
|
|
ups25InputFrequency NonNegativeInteger,
|
|
ups25InputVoltage NonNegativeInteger,
|
|
ups25InputCurrent NonNegativeInteger,
|
|
ups25InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups25InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups25InputEntry 1 }
|
|
|
|
ups25InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups25InputEntry 2 }
|
|
|
|
ups25InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups25InputEntry 3 }
|
|
|
|
ups25InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups25InputEntry 4 }
|
|
|
|
ups25InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups25InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups25Output OBJECT IDENTIFIER ::= { ups25Objects 4 }
|
|
|
|
ups25OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups25Output 1 }
|
|
|
|
ups25OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups25Output 2 }
|
|
|
|
ups25OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups25Output 3 }
|
|
|
|
ups25OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups25OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups25OutputNumLines."
|
|
::= { ups25Output 4 }
|
|
|
|
ups25OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups25OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups25OutputLineIndex }
|
|
::= { ups25OutputTable 1 }
|
|
|
|
Ups25OutputEntry ::= SEQUENCE {
|
|
ups25OutputLineIndex PositiveInteger,
|
|
ups25OutputVoltage NonNegativeInteger,
|
|
ups25OutputCurrent NonNegativeInteger,
|
|
ups25OutputPower NonNegativeInteger,
|
|
ups25OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups25OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups25OutputEntry 1 }
|
|
|
|
ups25OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups25OutputEntry 2 }
|
|
|
|
ups25OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups25OutputEntry 3 }
|
|
|
|
ups25OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups25OutputEntry 4 }
|
|
|
|
ups25OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups25OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups25Bypass OBJECT IDENTIFIER ::= { ups25Objects 5 }
|
|
|
|
ups25BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups25Bypass 1 }
|
|
|
|
ups25BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups25Bypass 2 }
|
|
|
|
ups25BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups25BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups25BypassNumLines."
|
|
::= { ups25Bypass 3 }
|
|
|
|
ups25BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups25BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups25BypassLineIndex }
|
|
::= { ups25BypassTable 1 }
|
|
|
|
Ups25BypassEntry ::= SEQUENCE {
|
|
ups25BypassLineIndex PositiveInteger,
|
|
ups25BypassVoltage NonNegativeInteger,
|
|
ups25BypassCurrent NonNegativeInteger,
|
|
ups25BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups25BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups25BypassEntry 1 }
|
|
|
|
ups25BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups25BypassEntry 2 }
|
|
|
|
ups25BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups25BypassEntry 3 }
|
|
|
|
ups25BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups25BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups25Alarm OBJECT IDENTIFIER ::= { ups25Objects 6 }
|
|
|
|
ups25AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups25Alarm 1 }
|
|
|
|
ups25AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups25AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups25AlarmId equal to 1, and increments the value of
|
|
ups25AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups25AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups25AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups25AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups25AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups25AlarmsPresent."
|
|
::= { ups25Alarm 2 }
|
|
|
|
ups25AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups25AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups25AlarmId }
|
|
::= { ups25AlarmTable 1 }
|
|
|
|
Ups25AlarmEntry ::= SEQUENCE {
|
|
ups25AlarmId PositiveInteger,
|
|
ups25AlarmDescr AutonomousType,
|
|
ups25AlarmTime TimeStamp
|
|
}
|
|
|
|
ups25AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups25AlarmEntry 1 }
|
|
|
|
ups25AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups25AlarmEntry 2 }
|
|
|
|
ups25AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups25AlarmTime shall equal
|
|
0."
|
|
::= { ups25AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups25WellKnownAlarms OBJECT IDENTIFIER ::= { ups25Alarm 3 }
|
|
ups25AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups25WellKnownAlarms 1 }
|
|
|
|
ups25AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups25WellKnownAlarms 2 }
|
|
|
|
ups25AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups25ConfigLowBattTime."
|
|
::= { ups25WellKnownAlarms 3 }
|
|
|
|
|
|
ups25AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups25WellKnownAlarms 4 }
|
|
|
|
ups25AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups25WellKnownAlarms 5 }
|
|
|
|
ups25AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups25WellKnownAlarms 6 }
|
|
|
|
ups25AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups25WellKnownAlarms 7 }
|
|
|
|
ups25AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups25WellKnownAlarms 8 }
|
|
|
|
ups25AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups25WellKnownAlarms 9 }
|
|
|
|
ups25AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups25WellKnownAlarms 10 }
|
|
|
|
ups25AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups25WellKnownAlarms 11 }
|
|
|
|
ups25AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups25WellKnownAlarms 12 }
|
|
|
|
ups25AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups25WellKnownAlarms 13 }
|
|
|
|
ups25AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups25WellKnownAlarms 14 }
|
|
|
|
ups25AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups25WellKnownAlarms 15 }
|
|
|
|
ups25AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups25WellKnownAlarms 16 }
|
|
|
|
ups25AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups25WellKnownAlarms 17 }
|
|
|
|
ups25AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups25WellKnownAlarms 18 }
|
|
|
|
ups25AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups25WellKnownAlarms 19 }
|
|
|
|
ups25AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups25WellKnownAlarms 20 }
|
|
|
|
ups25AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups25WellKnownAlarms 21 }
|
|
|
|
ups25AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups25ShutdownAfterDelay countdown is underway."
|
|
::= { ups25WellKnownAlarms 22 }
|
|
|
|
ups25AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups25WellKnownAlarms 23 }
|
|
|
|
ups25AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups25WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups25Test OBJECT IDENTIFIER ::= { ups25Objects 7 }
|
|
|
|
ups25TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups25TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups25TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups25TestId variable to
|
|
ups25TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups25TestNoTestsInitiated is returned."
|
|
::= { ups25Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups25TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups25TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups25TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups25TestResultsSummary */
|
|
get (upsTestSpinLock, ups25TestResultsSummary,
|
|
ups25TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups25TestResultsSummary,
|
|
ups25TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups25TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups25TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups25Test 2 }
|
|
|
|
ups25TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups25TestId to ups25TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups25Test 3 }
|
|
|
|
ups25TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups25TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups25Test 4 }
|
|
|
|
ups25TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups25TestResultsSummary is noTestsInitiated(6),
|
|
ups25TestStartTime has the value 0."
|
|
::= { ups25Test 5 }
|
|
|
|
ups25TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups25TestResultsSummary is noTestsInitiated(6),
|
|
ups25TestElapsedTime has the value 0."
|
|
::= { ups25Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups25WellKnownTests OBJECT IDENTIFIER ::= { ups25Test 7 }
|
|
|
|
|
|
ups25TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups25WellKnownTests 1 }
|
|
|
|
ups25TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups25WellKnownTests 2 }
|
|
|
|
ups25TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups25WellKnownTests 3 }
|
|
|
|
ups25TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups25WellKnownTests 4 }
|
|
|
|
ups25TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups25WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups25Control OBJECT IDENTIFIER ::= { ups25Objects 8 }
|
|
|
|
ups25ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups25ShutdownAfterDelay and ups25RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups25Control 1 }
|
|
|
|
ups25ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups25ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups25ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups25ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups25ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups25ShutdownAfterDelay already in effect."
|
|
::= { ups25Control 2 }
|
|
|
|
ups25StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups25StartupAfterDelay
|
|
countdown or ups25RebootWithDuration countdown in
|
|
progress. When read, ups25StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups25Control 3 }
|
|
|
|
ups25RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups25ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups25RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups25Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups25Traps OBJECT IDENTIFIER ::= { upsModule25 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups25TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups25EstimatedMinutesRemaining, ups25SecondsOnBattery,
|
|
ups25ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups25Traps 1 }
|
|
|
|
ups25TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups25TestId, ups25TestSpinLock,
|
|
ups25TestResultsSummary, ups25TestResultsDetail,
|
|
ups25TestStartTime, ups25TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups25Traps 2 }
|
|
|
|
ups25TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups25AlarmId, ups25AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups25AlarmOnBattery and
|
|
ups25AlarmTestInProgress."
|
|
::= { ups25Traps 3 }
|
|
|
|
ups25TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups25AlarmId, ups25AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups25AlarmTestInProgress."
|
|
::= { ups25Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups25Conformance OBJECT IDENTIFIER ::= { upsModule25 3 }
|
|
|
|
ups25Compliances OBJECT IDENTIFIER ::= { ups25Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups25SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups25SubsetIdentGroup,
|
|
ups25SubsetBatteryGroup, ups25SubsetInputGroup,
|
|
ups25SubsetOutputGroup, ups25SubsetAlarmGroup,
|
|
ups25SubsetControlGroup }
|
|
|
|
OBJECT ups25BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups25AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups25AlarmOnBattery, ups25AlarmLowBattery,
|
|
ups25AlarmInputBad, ups25AlarmUpsOutputOff,
|
|
ups25AlarmUpsSystemOff, and ups25AlarmTestInProgress."
|
|
|
|
OBJECT ups25OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups25ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups25Compliances 1 }
|
|
|
|
ups25BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups25BasicIdentGroup,
|
|
ups25BasicBatteryGroup, ups25BasicInputGroup,
|
|
ups25BasicOutputGroup, ups25BasicAlarmGroup,
|
|
ups25BasicTestGroup, ups25BasicControlGroup }
|
|
|
|
OBJECT ups25AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups25AlarmOnBattery, ups25AlarmLowBattery,
|
|
ups25AlarmDepletedBattery, ups25AlarmTempBad,
|
|
ups25AlarmInputBad, ups25AlarmOutputOverload,
|
|
ups25AlarmOnBypass, ups25AlarmBypassBad,
|
|
ups25AlarmOutputOffAsRequested,
|
|
ups25AlarmUpsOffAsRequested, ups25AlarmUpsOutputOff,
|
|
ups25AlarmUpsSystemOff, ups25AlarmGeneralFault,
|
|
ups25AlarmDiagnosticTestFailed,
|
|
ups25AlarmCommunicationsLost, ups25AlarmShutdownPending,
|
|
and ups25AlarmTestInProgress."
|
|
|
|
OBJECT ups25TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups25TestNoTestsInitiated."
|
|
|
|
OBJECT ups25OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups25BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups25BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups25ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups25Compliances 2 }
|
|
|
|
ups25FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups25FullIdentGroup, ups25FullBatteryGroup,
|
|
ups25FullInputGroup, ups25FullOutputGroup,
|
|
ups25FullAlarmGroup, ups25FullTestGroup,
|
|
ups25FullControlGroup }
|
|
|
|
OBJECT ups25AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups25AlarmBatteryBad, ups25AlarmOnBattery,
|
|
ups25AlarmLowBattery, ups25AlarmDepletedBattery,
|
|
ups25AlarmTempBad, ups25AlarmInputBad, ups25AlarmOnBypass,
|
|
ups25AlarmBypassBad, ups25AlarmOutputOffAsRequested,
|
|
ups25AlarmUpsOffAsRequested, ups25AlarmUpsOutputOff,
|
|
ups25AlarmUpsSystemOff, ups25AlarmGeneralFault,
|
|
ups25AlarmDiagnosticTestFailed,
|
|
ups25AlarmCommunicationsLost, ups25AlarmShutdownPending,
|
|
and ups25AlarmTestInProgress."
|
|
|
|
OBJECT ups25TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups25TestNoTestsInitiated,
|
|
ups25TestGeneralSystemsTest, and
|
|
ups25TestQuickBatteryTest."
|
|
|
|
OBJECT ups25OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups25FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups25FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups25ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups25Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups25Groups OBJECT IDENTIFIER ::= { ups25Conformance 2 }
|
|
|
|
ups25SubsetGroups OBJECT IDENTIFIER ::= { ups25Groups 1 }
|
|
|
|
ups25SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups25IdentManufacturer, ups25IdentModel,
|
|
ups25IdentAgentSoftwareVersion, ups25IdentName,
|
|
ups25IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups25SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups25SubsetGroups 1 }
|
|
|
|
ups25SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups25BatteryStatus, ups25SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups25SubsetGroups 2 }
|
|
|
|
ups25SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups25InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups25SubsetGroups 3 }
|
|
|
|
ups25SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups25OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups25SubsetGroups 4 }
|
|
|
|
|
|
-- { ups25SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups25SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups25AlarmsPresent, ups25AlarmDescr, ups25AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups25SubsetGroups 6 }
|
|
|
|
-- { ups25SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups25SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups25ShutdownType, ups25ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups25SubsetGroups 8 }
|
|
|
|
ups25BasicGroups OBJECT IDENTIFIER ::= { ups25Groups 2 }
|
|
|
|
ups25BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups25IdentManufacturer, ups25IdentModel,
|
|
ups25IdentUPSSoftwareVersion,
|
|
ups25IdentAgentSoftwareVersion, ups25IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 1 }
|
|
|
|
ups25BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups25BatteryStatus, ups25SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 2 }
|
|
|
|
ups25BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups25InputLineBads, ups25InputNumLines,
|
|
ups25InputFrequency, ups25InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 3 }
|
|
|
|
ups25BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups25OutputSource, ups25OutputFrequency,
|
|
ups25OutputNumLines, ups25OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 4 }
|
|
|
|
ups25BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups25BypassFrequency, ups25BypassNumLines,
|
|
ups25BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 5 }
|
|
|
|
ups25BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups25AlarmsPresent, ups25AlarmDescr, ups25AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups25BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 6 }
|
|
|
|
ups25BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups25TestId, ups25TestSpinLock,
|
|
ups25TestResultsSummary, ups25TestResultsDetail,
|
|
ups25TestStartTime, ups25TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 7 }
|
|
|
|
ups25BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups25ShutdownType, ups25ShutdownAfterDelay,
|
|
ups25StartupAfterDelay, ups25RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups25BasicGroups 8 }
|
|
|
|
ups25FullGroups OBJECT IDENTIFIER ::= { ups25Groups 3 }
|
|
|
|
ups25FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups25IdentManufacturer, ups25IdentModel,
|
|
ups25IdentUPSSoftwareVersion,
|
|
ups25IdentAgentSoftwareVersion, ups25IdentName,
|
|
ups25IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups25FullGroups 1 }
|
|
|
|
ups25FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups25BatteryStatus, ups25SecondsOnBattery,
|
|
ups25EstimatedMinutesRemaining,
|
|
ups25EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 2 }
|
|
|
|
ups25FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups25InputLineBads, ups25InputNumLines,
|
|
ups25InputFrequency, ups25InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 3 }
|
|
|
|
ups25FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups25OutputSource, ups25OutputFrequency,
|
|
ups25OutputNumLines, ups25OutputVoltage,
|
|
ups25OutputCurrent, ups25OutputPower,
|
|
ups25OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 4 }
|
|
|
|
ups25FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups25BypassFrequency, ups25BypassNumLines,
|
|
ups25BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 5 }
|
|
|
|
ups25FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups25AlarmsPresent, ups25AlarmDescr, ups25AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups25FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 6 }
|
|
|
|
ups25FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups25TestId, ups25TestSpinLock,
|
|
ups25TestResultsSummary, ups25TestResultsDetail,
|
|
ups25TestStartTime, ups25TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 7 }
|
|
|
|
ups25FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups25ShutdownType, ups25ShutdownAfterDelay,
|
|
ups25StartupAfterDelay, ups25RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups25FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups25FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 26 data
|
|
--
|
|
|
|
upsModule26 OBJECT IDENTIFIER ::= { upsModular 27 }
|
|
ups26Objects OBJECT IDENTIFIER ::= { upsModule26 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups26IdentName and
|
|
-- ups26IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups26Ident OBJECT IDENTIFIER ::= { ups26Objects 1 }
|
|
|
|
ups26IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups26Ident 1 }
|
|
|
|
ups26IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups26Ident 2 }
|
|
|
|
ups26IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups26IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups26Ident 3 }
|
|
|
|
ups26IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups26IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups26Ident 4 }
|
|
|
|
ups26IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups26Ident 5 }
|
|
|
|
ups26IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups26Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups26Battery OBJECT IDENTIFIER ::= { ups26Objects 2 }
|
|
|
|
ups26BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups26ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups26ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups26Battery 1 }
|
|
|
|
ups26SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups26Battery 2 }
|
|
|
|
ups26EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups26Battery 3 }
|
|
|
|
ups26EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups26Battery 4 }
|
|
|
|
ups26BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups26Battery 5 }
|
|
|
|
ups26BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups26Battery 6 }
|
|
|
|
ups26BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups26Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups26Input OBJECT IDENTIFIER ::= { ups26Objects 3 }
|
|
|
|
ups26InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups26Input 1 }
|
|
|
|
|
|
ups26InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups26Input 2 }
|
|
|
|
ups26InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups26InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups26InputNumLines."
|
|
::= { ups26Input 3 }
|
|
|
|
ups26InputEntry OBJECT-TYPE
|
|
SYNTAX Ups26InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups26InputLineIndex }
|
|
::= { ups26InputTable 1 }
|
|
|
|
Ups26InputEntry ::= SEQUENCE {
|
|
ups26InputLineIndex PositiveInteger,
|
|
ups26InputFrequency NonNegativeInteger,
|
|
ups26InputVoltage NonNegativeInteger,
|
|
ups26InputCurrent NonNegativeInteger,
|
|
ups26InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups26InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups26InputEntry 1 }
|
|
|
|
ups26InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups26InputEntry 2 }
|
|
|
|
ups26InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups26InputEntry 3 }
|
|
|
|
ups26InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups26InputEntry 4 }
|
|
|
|
ups26InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups26InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups26Output OBJECT IDENTIFIER ::= { ups26Objects 4 }
|
|
|
|
ups26OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups26Output 1 }
|
|
|
|
ups26OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups26Output 2 }
|
|
|
|
ups26OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups26Output 3 }
|
|
|
|
ups26OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups26OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups26OutputNumLines."
|
|
::= { ups26Output 4 }
|
|
|
|
ups26OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups26OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups26OutputLineIndex }
|
|
::= { ups26OutputTable 1 }
|
|
|
|
Ups26OutputEntry ::= SEQUENCE {
|
|
ups26OutputLineIndex PositiveInteger,
|
|
ups26OutputVoltage NonNegativeInteger,
|
|
ups26OutputCurrent NonNegativeInteger,
|
|
ups26OutputPower NonNegativeInteger,
|
|
ups26OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups26OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups26OutputEntry 1 }
|
|
|
|
ups26OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups26OutputEntry 2 }
|
|
|
|
ups26OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups26OutputEntry 3 }
|
|
|
|
ups26OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups26OutputEntry 4 }
|
|
|
|
ups26OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups26OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups26Bypass OBJECT IDENTIFIER ::= { ups26Objects 5 }
|
|
|
|
ups26BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups26Bypass 1 }
|
|
|
|
ups26BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups26Bypass 2 }
|
|
|
|
ups26BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups26BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups26BypassNumLines."
|
|
::= { ups26Bypass 3 }
|
|
|
|
ups26BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups26BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups26BypassLineIndex }
|
|
::= { ups26BypassTable 1 }
|
|
|
|
Ups26BypassEntry ::= SEQUENCE {
|
|
ups26BypassLineIndex PositiveInteger,
|
|
ups26BypassVoltage NonNegativeInteger,
|
|
ups26BypassCurrent NonNegativeInteger,
|
|
ups26BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups26BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups26BypassEntry 1 }
|
|
|
|
ups26BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups26BypassEntry 2 }
|
|
|
|
ups26BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups26BypassEntry 3 }
|
|
|
|
ups26BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups26BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups26Alarm OBJECT IDENTIFIER ::= { ups26Objects 6 }
|
|
|
|
ups26AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups26Alarm 1 }
|
|
|
|
ups26AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups26AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups26AlarmId equal to 1, and increments the value of
|
|
ups26AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups26AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups26AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups26AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups26AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups26AlarmsPresent."
|
|
::= { ups26Alarm 2 }
|
|
|
|
ups26AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups26AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups26AlarmId }
|
|
::= { ups26AlarmTable 1 }
|
|
|
|
Ups26AlarmEntry ::= SEQUENCE {
|
|
ups26AlarmId PositiveInteger,
|
|
ups26AlarmDescr AutonomousType,
|
|
ups26AlarmTime TimeStamp
|
|
}
|
|
|
|
ups26AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups26AlarmEntry 1 }
|
|
|
|
ups26AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups26AlarmEntry 2 }
|
|
|
|
ups26AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups26AlarmTime shall equal
|
|
0."
|
|
::= { ups26AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups26WellKnownAlarms OBJECT IDENTIFIER ::= { ups26Alarm 3 }
|
|
ups26AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups26WellKnownAlarms 1 }
|
|
|
|
ups26AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups26WellKnownAlarms 2 }
|
|
|
|
ups26AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups26ConfigLowBattTime."
|
|
::= { ups26WellKnownAlarms 3 }
|
|
|
|
|
|
ups26AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups26WellKnownAlarms 4 }
|
|
|
|
ups26AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups26WellKnownAlarms 5 }
|
|
|
|
ups26AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups26WellKnownAlarms 6 }
|
|
|
|
ups26AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups26WellKnownAlarms 7 }
|
|
|
|
ups26AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups26WellKnownAlarms 8 }
|
|
|
|
ups26AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups26WellKnownAlarms 9 }
|
|
|
|
ups26AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups26WellKnownAlarms 10 }
|
|
|
|
ups26AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups26WellKnownAlarms 11 }
|
|
|
|
ups26AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups26WellKnownAlarms 12 }
|
|
|
|
ups26AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups26WellKnownAlarms 13 }
|
|
|
|
ups26AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups26WellKnownAlarms 14 }
|
|
|
|
ups26AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups26WellKnownAlarms 15 }
|
|
|
|
ups26AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups26WellKnownAlarms 16 }
|
|
|
|
ups26AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups26WellKnownAlarms 17 }
|
|
|
|
ups26AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups26WellKnownAlarms 18 }
|
|
|
|
ups26AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups26WellKnownAlarms 19 }
|
|
|
|
ups26AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups26WellKnownAlarms 20 }
|
|
|
|
ups26AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups26WellKnownAlarms 21 }
|
|
|
|
ups26AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups26ShutdownAfterDelay countdown is underway."
|
|
::= { ups26WellKnownAlarms 22 }
|
|
|
|
ups26AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups26WellKnownAlarms 23 }
|
|
|
|
ups26AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups26WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups26Test OBJECT IDENTIFIER ::= { ups26Objects 7 }
|
|
|
|
ups26TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups26TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups26TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups26TestId variable to
|
|
ups26TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups26TestNoTestsInitiated is returned."
|
|
::= { ups26Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups26TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups26TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups26TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups26TestResultsSummary */
|
|
get (upsTestSpinLock, ups26TestResultsSummary,
|
|
ups26TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups26TestResultsSummary,
|
|
ups26TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups26TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups26TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups26Test 2 }
|
|
|
|
ups26TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups26TestId to ups26TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups26Test 3 }
|
|
|
|
ups26TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups26TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups26Test 4 }
|
|
|
|
ups26TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups26TestResultsSummary is noTestsInitiated(6),
|
|
ups26TestStartTime has the value 0."
|
|
::= { ups26Test 5 }
|
|
|
|
ups26TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups26TestResultsSummary is noTestsInitiated(6),
|
|
ups26TestElapsedTime has the value 0."
|
|
::= { ups26Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups26WellKnownTests OBJECT IDENTIFIER ::= { ups26Test 7 }
|
|
|
|
|
|
ups26TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups26WellKnownTests 1 }
|
|
|
|
ups26TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups26WellKnownTests 2 }
|
|
|
|
ups26TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups26WellKnownTests 3 }
|
|
|
|
ups26TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups26WellKnownTests 4 }
|
|
|
|
ups26TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups26WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups26Control OBJECT IDENTIFIER ::= { ups26Objects 8 }
|
|
|
|
ups26ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups26ShutdownAfterDelay and ups26RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups26Control 1 }
|
|
|
|
ups26ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups26ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups26ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups26ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups26ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups26ShutdownAfterDelay already in effect."
|
|
::= { ups26Control 2 }
|
|
|
|
ups26StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups26StartupAfterDelay
|
|
countdown or ups26RebootWithDuration countdown in
|
|
progress. When read, ups26StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups26Control 3 }
|
|
|
|
ups26RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups26ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups26RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups26Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups26Traps OBJECT IDENTIFIER ::= { upsModule26 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups26TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups26EstimatedMinutesRemaining, ups26SecondsOnBattery,
|
|
ups26ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups26Traps 1 }
|
|
|
|
ups26TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups26TestId, ups26TestSpinLock,
|
|
ups26TestResultsSummary, ups26TestResultsDetail,
|
|
ups26TestStartTime, ups26TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups26Traps 2 }
|
|
|
|
ups26TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups26AlarmId, ups26AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups26AlarmOnBattery and
|
|
ups26AlarmTestInProgress."
|
|
::= { ups26Traps 3 }
|
|
|
|
ups26TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups26AlarmId, ups26AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups26AlarmTestInProgress."
|
|
::= { ups26Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups26Conformance OBJECT IDENTIFIER ::= { upsModule26 3 }
|
|
|
|
ups26Compliances OBJECT IDENTIFIER ::= { ups26Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups26SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups26SubsetIdentGroup,
|
|
ups26SubsetBatteryGroup, ups26SubsetInputGroup,
|
|
ups26SubsetOutputGroup, ups26SubsetAlarmGroup,
|
|
ups26SubsetControlGroup }
|
|
|
|
OBJECT ups26BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups26AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups26AlarmOnBattery, ups26AlarmLowBattery,
|
|
ups26AlarmInputBad, ups26AlarmUpsOutputOff,
|
|
ups26AlarmUpsSystemOff, and ups26AlarmTestInProgress."
|
|
|
|
OBJECT ups26OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups26ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups26Compliances 1 }
|
|
|
|
ups26BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups26BasicIdentGroup,
|
|
ups26BasicBatteryGroup, ups26BasicInputGroup,
|
|
ups26BasicOutputGroup, ups26BasicAlarmGroup,
|
|
ups26BasicTestGroup, ups26BasicControlGroup }
|
|
|
|
OBJECT ups26AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups26AlarmOnBattery, ups26AlarmLowBattery,
|
|
ups26AlarmDepletedBattery, ups26AlarmTempBad,
|
|
ups26AlarmInputBad, ups26AlarmOutputOverload,
|
|
ups26AlarmOnBypass, ups26AlarmBypassBad,
|
|
ups26AlarmOutputOffAsRequested,
|
|
ups26AlarmUpsOffAsRequested, ups26AlarmUpsOutputOff,
|
|
ups26AlarmUpsSystemOff, ups26AlarmGeneralFault,
|
|
ups26AlarmDiagnosticTestFailed,
|
|
ups26AlarmCommunicationsLost, ups26AlarmShutdownPending,
|
|
and ups26AlarmTestInProgress."
|
|
|
|
OBJECT ups26TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups26TestNoTestsInitiated."
|
|
|
|
OBJECT ups26OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups26BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups26BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups26ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups26Compliances 2 }
|
|
|
|
ups26FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups26FullIdentGroup, ups26FullBatteryGroup,
|
|
ups26FullInputGroup, ups26FullOutputGroup,
|
|
ups26FullAlarmGroup, ups26FullTestGroup,
|
|
ups26FullControlGroup }
|
|
|
|
OBJECT ups26AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups26AlarmBatteryBad, ups26AlarmOnBattery,
|
|
ups26AlarmLowBattery, ups26AlarmDepletedBattery,
|
|
ups26AlarmTempBad, ups26AlarmInputBad, ups26AlarmOnBypass,
|
|
ups26AlarmBypassBad, ups26AlarmOutputOffAsRequested,
|
|
ups26AlarmUpsOffAsRequested, ups26AlarmUpsOutputOff,
|
|
ups26AlarmUpsSystemOff, ups26AlarmGeneralFault,
|
|
ups26AlarmDiagnosticTestFailed,
|
|
ups26AlarmCommunicationsLost, ups26AlarmShutdownPending,
|
|
and ups26AlarmTestInProgress."
|
|
|
|
OBJECT ups26TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups26TestNoTestsInitiated,
|
|
ups26TestGeneralSystemsTest, and
|
|
ups26TestQuickBatteryTest."
|
|
|
|
OBJECT ups26OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups26FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups26FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups26ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups26Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups26Groups OBJECT IDENTIFIER ::= { ups26Conformance 2 }
|
|
|
|
ups26SubsetGroups OBJECT IDENTIFIER ::= { ups26Groups 1 }
|
|
|
|
ups26SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups26IdentManufacturer, ups26IdentModel,
|
|
ups26IdentAgentSoftwareVersion, ups26IdentName,
|
|
ups26IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups26SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups26SubsetGroups 1 }
|
|
|
|
ups26SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups26BatteryStatus, ups26SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups26SubsetGroups 2 }
|
|
|
|
ups26SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups26InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups26SubsetGroups 3 }
|
|
|
|
ups26SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups26OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups26SubsetGroups 4 }
|
|
|
|
|
|
-- { ups26SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups26SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups26AlarmsPresent, ups26AlarmDescr, ups26AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups26SubsetGroups 6 }
|
|
|
|
-- { ups26SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups26SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups26ShutdownType, ups26ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups26SubsetGroups 8 }
|
|
|
|
ups26BasicGroups OBJECT IDENTIFIER ::= { ups26Groups 2 }
|
|
|
|
ups26BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups26IdentManufacturer, ups26IdentModel,
|
|
ups26IdentUPSSoftwareVersion,
|
|
ups26IdentAgentSoftwareVersion, ups26IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 1 }
|
|
|
|
ups26BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups26BatteryStatus, ups26SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 2 }
|
|
|
|
ups26BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups26InputLineBads, ups26InputNumLines,
|
|
ups26InputFrequency, ups26InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 3 }
|
|
|
|
ups26BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups26OutputSource, ups26OutputFrequency,
|
|
ups26OutputNumLines, ups26OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 4 }
|
|
|
|
ups26BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups26BypassFrequency, ups26BypassNumLines,
|
|
ups26BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 5 }
|
|
|
|
ups26BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups26AlarmsPresent, ups26AlarmDescr, ups26AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups26BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 6 }
|
|
|
|
ups26BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups26TestId, ups26TestSpinLock,
|
|
ups26TestResultsSummary, ups26TestResultsDetail,
|
|
ups26TestStartTime, ups26TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 7 }
|
|
|
|
ups26BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups26ShutdownType, ups26ShutdownAfterDelay,
|
|
ups26StartupAfterDelay, ups26RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups26BasicGroups 8 }
|
|
|
|
ups26FullGroups OBJECT IDENTIFIER ::= { ups26Groups 3 }
|
|
|
|
ups26FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups26IdentManufacturer, ups26IdentModel,
|
|
ups26IdentUPSSoftwareVersion,
|
|
ups26IdentAgentSoftwareVersion, ups26IdentName,
|
|
ups26IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups26FullGroups 1 }
|
|
|
|
ups26FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups26BatteryStatus, ups26SecondsOnBattery,
|
|
ups26EstimatedMinutesRemaining,
|
|
ups26EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 2 }
|
|
|
|
ups26FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups26InputLineBads, ups26InputNumLines,
|
|
ups26InputFrequency, ups26InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 3 }
|
|
|
|
ups26FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups26OutputSource, ups26OutputFrequency,
|
|
ups26OutputNumLines, ups26OutputVoltage,
|
|
ups26OutputCurrent, ups26OutputPower,
|
|
ups26OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 4 }
|
|
|
|
ups26FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups26BypassFrequency, ups26BypassNumLines,
|
|
ups26BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 5 }
|
|
|
|
ups26FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups26AlarmsPresent, ups26AlarmDescr, ups26AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups26FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 6 }
|
|
|
|
ups26FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups26TestId, ups26TestSpinLock,
|
|
ups26TestResultsSummary, ups26TestResultsDetail,
|
|
ups26TestStartTime, ups26TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 7 }
|
|
|
|
ups26FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups26ShutdownType, ups26ShutdownAfterDelay,
|
|
ups26StartupAfterDelay, ups26RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups26FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups26FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 27 data
|
|
--
|
|
|
|
upsModule27 OBJECT IDENTIFIER ::= { upsModular 28 }
|
|
ups27Objects OBJECT IDENTIFIER ::= { upsModule27 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups27IdentName and
|
|
-- ups27IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups27Ident OBJECT IDENTIFIER ::= { ups27Objects 1 }
|
|
|
|
ups27IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups27Ident 1 }
|
|
|
|
ups27IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups27Ident 2 }
|
|
|
|
ups27IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups27IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups27Ident 3 }
|
|
|
|
ups27IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups27IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups27Ident 4 }
|
|
|
|
ups27IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups27Ident 5 }
|
|
|
|
ups27IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups27Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups27Battery OBJECT IDENTIFIER ::= { ups27Objects 2 }
|
|
|
|
ups27BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups27ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups27ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups27Battery 1 }
|
|
|
|
ups27SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups27Battery 2 }
|
|
|
|
ups27EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups27Battery 3 }
|
|
|
|
ups27EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups27Battery 4 }
|
|
|
|
ups27BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups27Battery 5 }
|
|
|
|
ups27BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups27Battery 6 }
|
|
|
|
ups27BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups27Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups27Input OBJECT IDENTIFIER ::= { ups27Objects 3 }
|
|
|
|
ups27InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups27Input 1 }
|
|
|
|
|
|
ups27InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups27Input 2 }
|
|
|
|
ups27InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups27InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups27InputNumLines."
|
|
::= { ups27Input 3 }
|
|
|
|
ups27InputEntry OBJECT-TYPE
|
|
SYNTAX Ups27InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups27InputLineIndex }
|
|
::= { ups27InputTable 1 }
|
|
|
|
Ups27InputEntry ::= SEQUENCE {
|
|
ups27InputLineIndex PositiveInteger,
|
|
ups27InputFrequency NonNegativeInteger,
|
|
ups27InputVoltage NonNegativeInteger,
|
|
ups27InputCurrent NonNegativeInteger,
|
|
ups27InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups27InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups27InputEntry 1 }
|
|
|
|
ups27InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups27InputEntry 2 }
|
|
|
|
ups27InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups27InputEntry 3 }
|
|
|
|
ups27InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups27InputEntry 4 }
|
|
|
|
ups27InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups27InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups27Output OBJECT IDENTIFIER ::= { ups27Objects 4 }
|
|
|
|
ups27OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups27Output 1 }
|
|
|
|
ups27OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups27Output 2 }
|
|
|
|
ups27OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups27Output 3 }
|
|
|
|
ups27OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups27OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups27OutputNumLines."
|
|
::= { ups27Output 4 }
|
|
|
|
ups27OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups27OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups27OutputLineIndex }
|
|
::= { ups27OutputTable 1 }
|
|
|
|
Ups27OutputEntry ::= SEQUENCE {
|
|
ups27OutputLineIndex PositiveInteger,
|
|
ups27OutputVoltage NonNegativeInteger,
|
|
ups27OutputCurrent NonNegativeInteger,
|
|
ups27OutputPower NonNegativeInteger,
|
|
ups27OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups27OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups27OutputEntry 1 }
|
|
|
|
ups27OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups27OutputEntry 2 }
|
|
|
|
ups27OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups27OutputEntry 3 }
|
|
|
|
ups27OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups27OutputEntry 4 }
|
|
|
|
ups27OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups27OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups27Bypass OBJECT IDENTIFIER ::= { ups27Objects 5 }
|
|
|
|
ups27BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups27Bypass 1 }
|
|
|
|
ups27BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups27Bypass 2 }
|
|
|
|
ups27BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups27BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups27BypassNumLines."
|
|
::= { ups27Bypass 3 }
|
|
|
|
ups27BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups27BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups27BypassLineIndex }
|
|
::= { ups27BypassTable 1 }
|
|
|
|
Ups27BypassEntry ::= SEQUENCE {
|
|
ups27BypassLineIndex PositiveInteger,
|
|
ups27BypassVoltage NonNegativeInteger,
|
|
ups27BypassCurrent NonNegativeInteger,
|
|
ups27BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups27BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups27BypassEntry 1 }
|
|
|
|
ups27BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups27BypassEntry 2 }
|
|
|
|
ups27BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups27BypassEntry 3 }
|
|
|
|
ups27BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups27BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups27Alarm OBJECT IDENTIFIER ::= { ups27Objects 6 }
|
|
|
|
ups27AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups27Alarm 1 }
|
|
|
|
ups27AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups27AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups27AlarmId equal to 1, and increments the value of
|
|
ups27AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups27AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups27AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups27AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups27AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups27AlarmsPresent."
|
|
::= { ups27Alarm 2 }
|
|
|
|
ups27AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups27AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups27AlarmId }
|
|
::= { ups27AlarmTable 1 }
|
|
|
|
Ups27AlarmEntry ::= SEQUENCE {
|
|
ups27AlarmId PositiveInteger,
|
|
ups27AlarmDescr AutonomousType,
|
|
ups27AlarmTime TimeStamp
|
|
}
|
|
|
|
ups27AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups27AlarmEntry 1 }
|
|
|
|
ups27AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups27AlarmEntry 2 }
|
|
|
|
ups27AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups27AlarmTime shall equal
|
|
0."
|
|
::= { ups27AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups27WellKnownAlarms OBJECT IDENTIFIER ::= { ups27Alarm 3 }
|
|
ups27AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups27WellKnownAlarms 1 }
|
|
|
|
ups27AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups27WellKnownAlarms 2 }
|
|
|
|
ups27AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups27ConfigLowBattTime."
|
|
::= { ups27WellKnownAlarms 3 }
|
|
|
|
|
|
ups27AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups27WellKnownAlarms 4 }
|
|
|
|
ups27AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups27WellKnownAlarms 5 }
|
|
|
|
ups27AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups27WellKnownAlarms 6 }
|
|
|
|
ups27AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups27WellKnownAlarms 7 }
|
|
|
|
ups27AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups27WellKnownAlarms 8 }
|
|
|
|
ups27AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups27WellKnownAlarms 9 }
|
|
|
|
ups27AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups27WellKnownAlarms 10 }
|
|
|
|
ups27AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups27WellKnownAlarms 11 }
|
|
|
|
ups27AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups27WellKnownAlarms 12 }
|
|
|
|
ups27AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups27WellKnownAlarms 13 }
|
|
|
|
ups27AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups27WellKnownAlarms 14 }
|
|
|
|
ups27AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups27WellKnownAlarms 15 }
|
|
|
|
ups27AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups27WellKnownAlarms 16 }
|
|
|
|
ups27AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups27WellKnownAlarms 17 }
|
|
|
|
ups27AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups27WellKnownAlarms 18 }
|
|
|
|
ups27AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups27WellKnownAlarms 19 }
|
|
|
|
ups27AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups27WellKnownAlarms 20 }
|
|
|
|
ups27AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups27WellKnownAlarms 21 }
|
|
|
|
ups27AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups27ShutdownAfterDelay countdown is underway."
|
|
::= { ups27WellKnownAlarms 22 }
|
|
|
|
ups27AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups27WellKnownAlarms 23 }
|
|
|
|
ups27AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups27WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups27Test OBJECT IDENTIFIER ::= { ups27Objects 7 }
|
|
|
|
ups27TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups27TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups27TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups27TestId variable to
|
|
ups27TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups27TestNoTestsInitiated is returned."
|
|
::= { ups27Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups27TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups27TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups27TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups27TestResultsSummary */
|
|
get (upsTestSpinLock, ups27TestResultsSummary,
|
|
ups27TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups27TestResultsSummary,
|
|
ups27TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups27TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups27TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups27Test 2 }
|
|
|
|
ups27TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups27TestId to ups27TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups27Test 3 }
|
|
|
|
ups27TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups27TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups27Test 4 }
|
|
|
|
ups27TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups27TestResultsSummary is noTestsInitiated(6),
|
|
ups27TestStartTime has the value 0."
|
|
::= { ups27Test 5 }
|
|
|
|
ups27TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups27TestResultsSummary is noTestsInitiated(6),
|
|
ups27TestElapsedTime has the value 0."
|
|
::= { ups27Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups27WellKnownTests OBJECT IDENTIFIER ::= { ups27Test 7 }
|
|
|
|
|
|
ups27TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups27WellKnownTests 1 }
|
|
|
|
ups27TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups27WellKnownTests 2 }
|
|
|
|
ups27TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups27WellKnownTests 3 }
|
|
|
|
ups27TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups27WellKnownTests 4 }
|
|
|
|
ups27TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups27WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups27Control OBJECT IDENTIFIER ::= { ups27Objects 8 }
|
|
|
|
ups27ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups27ShutdownAfterDelay and ups27RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups27Control 1 }
|
|
|
|
ups27ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups27ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups27ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups27ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups27ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups27ShutdownAfterDelay already in effect."
|
|
::= { ups27Control 2 }
|
|
|
|
ups27StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups27StartupAfterDelay
|
|
countdown or ups27RebootWithDuration countdown in
|
|
progress. When read, ups27StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups27Control 3 }
|
|
|
|
ups27RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups27ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups27RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups27Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups27Traps OBJECT IDENTIFIER ::= { upsModule27 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups27TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups27EstimatedMinutesRemaining, ups27SecondsOnBattery,
|
|
ups27ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups27Traps 1 }
|
|
|
|
ups27TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups27TestId, ups27TestSpinLock,
|
|
ups27TestResultsSummary, ups27TestResultsDetail,
|
|
ups27TestStartTime, ups27TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups27Traps 2 }
|
|
|
|
ups27TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups27AlarmId, ups27AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups27AlarmOnBattery and
|
|
ups27AlarmTestInProgress."
|
|
::= { ups27Traps 3 }
|
|
|
|
ups27TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups27AlarmId, ups27AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups27AlarmTestInProgress."
|
|
::= { ups27Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups27Conformance OBJECT IDENTIFIER ::= { upsModule27 3 }
|
|
|
|
ups27Compliances OBJECT IDENTIFIER ::= { ups27Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups27SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups27SubsetIdentGroup,
|
|
ups27SubsetBatteryGroup, ups27SubsetInputGroup,
|
|
ups27SubsetOutputGroup, ups27SubsetAlarmGroup,
|
|
ups27SubsetControlGroup }
|
|
|
|
OBJECT ups27BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups27AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups27AlarmOnBattery, ups27AlarmLowBattery,
|
|
ups27AlarmInputBad, ups27AlarmUpsOutputOff,
|
|
ups27AlarmUpsSystemOff, and ups27AlarmTestInProgress."
|
|
|
|
OBJECT ups27OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups27ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups27Compliances 1 }
|
|
|
|
ups27BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups27BasicIdentGroup,
|
|
ups27BasicBatteryGroup, ups27BasicInputGroup,
|
|
ups27BasicOutputGroup, ups27BasicAlarmGroup,
|
|
ups27BasicTestGroup, ups27BasicControlGroup }
|
|
|
|
OBJECT ups27AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups27AlarmOnBattery, ups27AlarmLowBattery,
|
|
ups27AlarmDepletedBattery, ups27AlarmTempBad,
|
|
ups27AlarmInputBad, ups27AlarmOutputOverload,
|
|
ups27AlarmOnBypass, ups27AlarmBypassBad,
|
|
ups27AlarmOutputOffAsRequested,
|
|
ups27AlarmUpsOffAsRequested, ups27AlarmUpsOutputOff,
|
|
ups27AlarmUpsSystemOff, ups27AlarmGeneralFault,
|
|
ups27AlarmDiagnosticTestFailed,
|
|
ups27AlarmCommunicationsLost, ups27AlarmShutdownPending,
|
|
and ups27AlarmTestInProgress."
|
|
|
|
OBJECT ups27TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups27TestNoTestsInitiated."
|
|
|
|
OBJECT ups27OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups27BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups27BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups27ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups27Compliances 2 }
|
|
|
|
ups27FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups27FullIdentGroup, ups27FullBatteryGroup,
|
|
ups27FullInputGroup, ups27FullOutputGroup,
|
|
ups27FullAlarmGroup, ups27FullTestGroup,
|
|
ups27FullControlGroup }
|
|
|
|
OBJECT ups27AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups27AlarmBatteryBad, ups27AlarmOnBattery,
|
|
ups27AlarmLowBattery, ups27AlarmDepletedBattery,
|
|
ups27AlarmTempBad, ups27AlarmInputBad, ups27AlarmOnBypass,
|
|
ups27AlarmBypassBad, ups27AlarmOutputOffAsRequested,
|
|
ups27AlarmUpsOffAsRequested, ups27AlarmUpsOutputOff,
|
|
ups27AlarmUpsSystemOff, ups27AlarmGeneralFault,
|
|
ups27AlarmDiagnosticTestFailed,
|
|
ups27AlarmCommunicationsLost, ups27AlarmShutdownPending,
|
|
and ups27AlarmTestInProgress."
|
|
|
|
OBJECT ups27TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups27TestNoTestsInitiated,
|
|
ups27TestGeneralSystemsTest, and
|
|
ups27TestQuickBatteryTest."
|
|
|
|
OBJECT ups27OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups27FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups27FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups27ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups27Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups27Groups OBJECT IDENTIFIER ::= { ups27Conformance 2 }
|
|
|
|
ups27SubsetGroups OBJECT IDENTIFIER ::= { ups27Groups 1 }
|
|
|
|
ups27SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups27IdentManufacturer, ups27IdentModel,
|
|
ups27IdentAgentSoftwareVersion, ups27IdentName,
|
|
ups27IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups27SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups27SubsetGroups 1 }
|
|
|
|
ups27SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups27BatteryStatus, ups27SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups27SubsetGroups 2 }
|
|
|
|
ups27SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups27InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups27SubsetGroups 3 }
|
|
|
|
ups27SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups27OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups27SubsetGroups 4 }
|
|
|
|
|
|
-- { ups27SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups27SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups27AlarmsPresent, ups27AlarmDescr, ups27AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups27SubsetGroups 6 }
|
|
|
|
-- { ups27SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups27SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups27ShutdownType, ups27ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups27SubsetGroups 8 }
|
|
|
|
ups27BasicGroups OBJECT IDENTIFIER ::= { ups27Groups 2 }
|
|
|
|
ups27BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups27IdentManufacturer, ups27IdentModel,
|
|
ups27IdentUPSSoftwareVersion,
|
|
ups27IdentAgentSoftwareVersion, ups27IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 1 }
|
|
|
|
ups27BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups27BatteryStatus, ups27SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 2 }
|
|
|
|
ups27BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups27InputLineBads, ups27InputNumLines,
|
|
ups27InputFrequency, ups27InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 3 }
|
|
|
|
ups27BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups27OutputSource, ups27OutputFrequency,
|
|
ups27OutputNumLines, ups27OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 4 }
|
|
|
|
ups27BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups27BypassFrequency, ups27BypassNumLines,
|
|
ups27BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 5 }
|
|
|
|
ups27BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups27AlarmsPresent, ups27AlarmDescr, ups27AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups27BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 6 }
|
|
|
|
ups27BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups27TestId, ups27TestSpinLock,
|
|
ups27TestResultsSummary, ups27TestResultsDetail,
|
|
ups27TestStartTime, ups27TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 7 }
|
|
|
|
ups27BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups27ShutdownType, ups27ShutdownAfterDelay,
|
|
ups27StartupAfterDelay, ups27RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups27BasicGroups 8 }
|
|
|
|
ups27FullGroups OBJECT IDENTIFIER ::= { ups27Groups 3 }
|
|
|
|
ups27FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups27IdentManufacturer, ups27IdentModel,
|
|
ups27IdentUPSSoftwareVersion,
|
|
ups27IdentAgentSoftwareVersion, ups27IdentName,
|
|
ups27IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups27FullGroups 1 }
|
|
|
|
ups27FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups27BatteryStatus, ups27SecondsOnBattery,
|
|
ups27EstimatedMinutesRemaining,
|
|
ups27EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 2 }
|
|
|
|
ups27FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups27InputLineBads, ups27InputNumLines,
|
|
ups27InputFrequency, ups27InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 3 }
|
|
|
|
ups27FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups27OutputSource, ups27OutputFrequency,
|
|
ups27OutputNumLines, ups27OutputVoltage,
|
|
ups27OutputCurrent, ups27OutputPower,
|
|
ups27OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 4 }
|
|
|
|
ups27FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups27BypassFrequency, ups27BypassNumLines,
|
|
ups27BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 5 }
|
|
|
|
ups27FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups27AlarmsPresent, ups27AlarmDescr, ups27AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups27FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 6 }
|
|
|
|
ups27FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups27TestId, ups27TestSpinLock,
|
|
ups27TestResultsSummary, ups27TestResultsDetail,
|
|
ups27TestStartTime, ups27TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 7 }
|
|
|
|
ups27FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups27ShutdownType, ups27ShutdownAfterDelay,
|
|
ups27StartupAfterDelay, ups27RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups27FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups27FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 28 data
|
|
--
|
|
|
|
upsModule28 OBJECT IDENTIFIER ::= { upsModular 29 }
|
|
ups28Objects OBJECT IDENTIFIER ::= { upsModule28 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups28IdentName and
|
|
-- ups28IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups28Ident OBJECT IDENTIFIER ::= { ups28Objects 1 }
|
|
|
|
ups28IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups28Ident 1 }
|
|
|
|
ups28IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups28Ident 2 }
|
|
|
|
ups28IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups28IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups28Ident 3 }
|
|
|
|
ups28IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups28IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups28Ident 4 }
|
|
|
|
ups28IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups28Ident 5 }
|
|
|
|
ups28IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups28Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups28Battery OBJECT IDENTIFIER ::= { ups28Objects 2 }
|
|
|
|
ups28BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups28ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups28ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups28Battery 1 }
|
|
|
|
ups28SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups28Battery 2 }
|
|
|
|
ups28EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups28Battery 3 }
|
|
|
|
ups28EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups28Battery 4 }
|
|
|
|
ups28BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups28Battery 5 }
|
|
|
|
ups28BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups28Battery 6 }
|
|
|
|
ups28BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups28Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups28Input OBJECT IDENTIFIER ::= { ups28Objects 3 }
|
|
|
|
ups28InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups28Input 1 }
|
|
|
|
|
|
ups28InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups28Input 2 }
|
|
|
|
ups28InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups28InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups28InputNumLines."
|
|
::= { ups28Input 3 }
|
|
|
|
ups28InputEntry OBJECT-TYPE
|
|
SYNTAX Ups28InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups28InputLineIndex }
|
|
::= { ups28InputTable 1 }
|
|
|
|
Ups28InputEntry ::= SEQUENCE {
|
|
ups28InputLineIndex PositiveInteger,
|
|
ups28InputFrequency NonNegativeInteger,
|
|
ups28InputVoltage NonNegativeInteger,
|
|
ups28InputCurrent NonNegativeInteger,
|
|
ups28InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups28InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups28InputEntry 1 }
|
|
|
|
ups28InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups28InputEntry 2 }
|
|
|
|
ups28InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups28InputEntry 3 }
|
|
|
|
ups28InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups28InputEntry 4 }
|
|
|
|
ups28InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups28InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups28Output OBJECT IDENTIFIER ::= { ups28Objects 4 }
|
|
|
|
ups28OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups28Output 1 }
|
|
|
|
ups28OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups28Output 2 }
|
|
|
|
ups28OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups28Output 3 }
|
|
|
|
ups28OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups28OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups28OutputNumLines."
|
|
::= { ups28Output 4 }
|
|
|
|
ups28OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups28OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups28OutputLineIndex }
|
|
::= { ups28OutputTable 1 }
|
|
|
|
Ups28OutputEntry ::= SEQUENCE {
|
|
ups28OutputLineIndex PositiveInteger,
|
|
ups28OutputVoltage NonNegativeInteger,
|
|
ups28OutputCurrent NonNegativeInteger,
|
|
ups28OutputPower NonNegativeInteger,
|
|
ups28OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups28OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups28OutputEntry 1 }
|
|
|
|
ups28OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups28OutputEntry 2 }
|
|
|
|
ups28OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups28OutputEntry 3 }
|
|
|
|
ups28OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups28OutputEntry 4 }
|
|
|
|
ups28OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups28OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups28Bypass OBJECT IDENTIFIER ::= { ups28Objects 5 }
|
|
|
|
ups28BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups28Bypass 1 }
|
|
|
|
ups28BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups28Bypass 2 }
|
|
|
|
ups28BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups28BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups28BypassNumLines."
|
|
::= { ups28Bypass 3 }
|
|
|
|
ups28BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups28BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups28BypassLineIndex }
|
|
::= { ups28BypassTable 1 }
|
|
|
|
Ups28BypassEntry ::= SEQUENCE {
|
|
ups28BypassLineIndex PositiveInteger,
|
|
ups28BypassVoltage NonNegativeInteger,
|
|
ups28BypassCurrent NonNegativeInteger,
|
|
ups28BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups28BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups28BypassEntry 1 }
|
|
|
|
ups28BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups28BypassEntry 2 }
|
|
|
|
ups28BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups28BypassEntry 3 }
|
|
|
|
ups28BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups28BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups28Alarm OBJECT IDENTIFIER ::= { ups28Objects 6 }
|
|
|
|
ups28AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups28Alarm 1 }
|
|
|
|
ups28AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups28AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups28AlarmId equal to 1, and increments the value of
|
|
ups28AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups28AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups28AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups28AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups28AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups28AlarmsPresent."
|
|
::= { ups28Alarm 2 }
|
|
|
|
ups28AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups28AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups28AlarmId }
|
|
::= { ups28AlarmTable 1 }
|
|
|
|
Ups28AlarmEntry ::= SEQUENCE {
|
|
ups28AlarmId PositiveInteger,
|
|
ups28AlarmDescr AutonomousType,
|
|
ups28AlarmTime TimeStamp
|
|
}
|
|
|
|
ups28AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups28AlarmEntry 1 }
|
|
|
|
ups28AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups28AlarmEntry 2 }
|
|
|
|
ups28AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups28AlarmTime shall equal
|
|
0."
|
|
::= { ups28AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups28WellKnownAlarms OBJECT IDENTIFIER ::= { ups28Alarm 3 }
|
|
ups28AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups28WellKnownAlarms 1 }
|
|
|
|
ups28AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups28WellKnownAlarms 2 }
|
|
|
|
ups28AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups28ConfigLowBattTime."
|
|
::= { ups28WellKnownAlarms 3 }
|
|
|
|
|
|
ups28AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups28WellKnownAlarms 4 }
|
|
|
|
ups28AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups28WellKnownAlarms 5 }
|
|
|
|
ups28AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups28WellKnownAlarms 6 }
|
|
|
|
ups28AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups28WellKnownAlarms 7 }
|
|
|
|
ups28AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups28WellKnownAlarms 8 }
|
|
|
|
ups28AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups28WellKnownAlarms 9 }
|
|
|
|
ups28AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups28WellKnownAlarms 10 }
|
|
|
|
ups28AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups28WellKnownAlarms 11 }
|
|
|
|
ups28AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups28WellKnownAlarms 12 }
|
|
|
|
ups28AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups28WellKnownAlarms 13 }
|
|
|
|
ups28AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups28WellKnownAlarms 14 }
|
|
|
|
ups28AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups28WellKnownAlarms 15 }
|
|
|
|
ups28AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups28WellKnownAlarms 16 }
|
|
|
|
ups28AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups28WellKnownAlarms 17 }
|
|
|
|
ups28AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups28WellKnownAlarms 18 }
|
|
|
|
ups28AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups28WellKnownAlarms 19 }
|
|
|
|
ups28AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups28WellKnownAlarms 20 }
|
|
|
|
ups28AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups28WellKnownAlarms 21 }
|
|
|
|
ups28AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups28ShutdownAfterDelay countdown is underway."
|
|
::= { ups28WellKnownAlarms 22 }
|
|
|
|
ups28AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups28WellKnownAlarms 23 }
|
|
|
|
ups28AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups28WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups28Test OBJECT IDENTIFIER ::= { ups28Objects 7 }
|
|
|
|
ups28TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups28TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups28TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups28TestId variable to
|
|
ups28TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups28TestNoTestsInitiated is returned."
|
|
::= { ups28Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups28TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups28TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups28TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups28TestResultsSummary */
|
|
get (upsTestSpinLock, ups28TestResultsSummary,
|
|
ups28TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups28TestResultsSummary,
|
|
ups28TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups28TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups28TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups28Test 2 }
|
|
|
|
ups28TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups28TestId to ups28TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups28Test 3 }
|
|
|
|
ups28TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups28TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups28Test 4 }
|
|
|
|
ups28TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups28TestResultsSummary is noTestsInitiated(6),
|
|
ups28TestStartTime has the value 0."
|
|
::= { ups28Test 5 }
|
|
|
|
ups28TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups28TestResultsSummary is noTestsInitiated(6),
|
|
ups28TestElapsedTime has the value 0."
|
|
::= { ups28Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups28WellKnownTests OBJECT IDENTIFIER ::= { ups28Test 7 }
|
|
|
|
|
|
ups28TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups28WellKnownTests 1 }
|
|
|
|
ups28TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups28WellKnownTests 2 }
|
|
|
|
ups28TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups28WellKnownTests 3 }
|
|
|
|
ups28TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups28WellKnownTests 4 }
|
|
|
|
ups28TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups28WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups28Control OBJECT IDENTIFIER ::= { ups28Objects 8 }
|
|
|
|
ups28ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups28ShutdownAfterDelay and ups28RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups28Control 1 }
|
|
|
|
ups28ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups28ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups28ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups28ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups28ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups28ShutdownAfterDelay already in effect."
|
|
::= { ups28Control 2 }
|
|
|
|
ups28StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups28StartupAfterDelay
|
|
countdown or ups28RebootWithDuration countdown in
|
|
progress. When read, ups28StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups28Control 3 }
|
|
|
|
ups28RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups28ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups28RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups28Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups28Traps OBJECT IDENTIFIER ::= { upsModule28 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups28TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups28EstimatedMinutesRemaining, ups28SecondsOnBattery,
|
|
ups28ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups28Traps 1 }
|
|
|
|
ups28TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups28TestId, ups28TestSpinLock,
|
|
ups28TestResultsSummary, ups28TestResultsDetail,
|
|
ups28TestStartTime, ups28TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups28Traps 2 }
|
|
|
|
ups28TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups28AlarmId, ups28AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups28AlarmOnBattery and
|
|
ups28AlarmTestInProgress."
|
|
::= { ups28Traps 3 }
|
|
|
|
ups28TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups28AlarmId, ups28AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups28AlarmTestInProgress."
|
|
::= { ups28Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups28Conformance OBJECT IDENTIFIER ::= { upsModule28 3 }
|
|
|
|
ups28Compliances OBJECT IDENTIFIER ::= { ups28Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups28SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups28SubsetIdentGroup,
|
|
ups28SubsetBatteryGroup, ups28SubsetInputGroup,
|
|
ups28SubsetOutputGroup, ups28SubsetAlarmGroup,
|
|
ups28SubsetControlGroup }
|
|
|
|
OBJECT ups28BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups28AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups28AlarmOnBattery, ups28AlarmLowBattery,
|
|
ups28AlarmInputBad, ups28AlarmUpsOutputOff,
|
|
ups28AlarmUpsSystemOff, and ups28AlarmTestInProgress."
|
|
|
|
OBJECT ups28OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups28ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups28Compliances 1 }
|
|
|
|
ups28BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups28BasicIdentGroup,
|
|
ups28BasicBatteryGroup, ups28BasicInputGroup,
|
|
ups28BasicOutputGroup, ups28BasicAlarmGroup,
|
|
ups28BasicTestGroup, ups28BasicControlGroup }
|
|
|
|
OBJECT ups28AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups28AlarmOnBattery, ups28AlarmLowBattery,
|
|
ups28AlarmDepletedBattery, ups28AlarmTempBad,
|
|
ups28AlarmInputBad, ups28AlarmOutputOverload,
|
|
ups28AlarmOnBypass, ups28AlarmBypassBad,
|
|
ups28AlarmOutputOffAsRequested,
|
|
ups28AlarmUpsOffAsRequested, ups28AlarmUpsOutputOff,
|
|
ups28AlarmUpsSystemOff, ups28AlarmGeneralFault,
|
|
ups28AlarmDiagnosticTestFailed,
|
|
ups28AlarmCommunicationsLost, ups28AlarmShutdownPending,
|
|
and ups28AlarmTestInProgress."
|
|
|
|
OBJECT ups28TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups28TestNoTestsInitiated."
|
|
|
|
OBJECT ups28OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups28BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups28BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups28ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups28Compliances 2 }
|
|
|
|
ups28FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups28FullIdentGroup, ups28FullBatteryGroup,
|
|
ups28FullInputGroup, ups28FullOutputGroup,
|
|
ups28FullAlarmGroup, ups28FullTestGroup,
|
|
ups28FullControlGroup }
|
|
|
|
OBJECT ups28AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups28AlarmBatteryBad, ups28AlarmOnBattery,
|
|
ups28AlarmLowBattery, ups28AlarmDepletedBattery,
|
|
ups28AlarmTempBad, ups28AlarmInputBad, ups28AlarmOnBypass,
|
|
ups28AlarmBypassBad, ups28AlarmOutputOffAsRequested,
|
|
ups28AlarmUpsOffAsRequested, ups28AlarmUpsOutputOff,
|
|
ups28AlarmUpsSystemOff, ups28AlarmGeneralFault,
|
|
ups28AlarmDiagnosticTestFailed,
|
|
ups28AlarmCommunicationsLost, ups28AlarmShutdownPending,
|
|
and ups28AlarmTestInProgress."
|
|
|
|
OBJECT ups28TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups28TestNoTestsInitiated,
|
|
ups28TestGeneralSystemsTest, and
|
|
ups28TestQuickBatteryTest."
|
|
|
|
OBJECT ups28OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups28FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups28FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups28ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups28Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups28Groups OBJECT IDENTIFIER ::= { ups28Conformance 2 }
|
|
|
|
ups28SubsetGroups OBJECT IDENTIFIER ::= { ups28Groups 1 }
|
|
|
|
ups28SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups28IdentManufacturer, ups28IdentModel,
|
|
ups28IdentAgentSoftwareVersion, ups28IdentName,
|
|
ups28IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups28SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups28SubsetGroups 1 }
|
|
|
|
ups28SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups28BatteryStatus, ups28SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups28SubsetGroups 2 }
|
|
|
|
ups28SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups28InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups28SubsetGroups 3 }
|
|
|
|
ups28SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups28OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups28SubsetGroups 4 }
|
|
|
|
|
|
-- { ups28SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups28SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups28AlarmsPresent, ups28AlarmDescr, ups28AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups28SubsetGroups 6 }
|
|
|
|
-- { ups28SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups28SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups28ShutdownType, ups28ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups28SubsetGroups 8 }
|
|
|
|
ups28BasicGroups OBJECT IDENTIFIER ::= { ups28Groups 2 }
|
|
|
|
ups28BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups28IdentManufacturer, ups28IdentModel,
|
|
ups28IdentUPSSoftwareVersion,
|
|
ups28IdentAgentSoftwareVersion, ups28IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 1 }
|
|
|
|
ups28BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups28BatteryStatus, ups28SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 2 }
|
|
|
|
ups28BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups28InputLineBads, ups28InputNumLines,
|
|
ups28InputFrequency, ups28InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 3 }
|
|
|
|
ups28BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups28OutputSource, ups28OutputFrequency,
|
|
ups28OutputNumLines, ups28OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 4 }
|
|
|
|
ups28BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups28BypassFrequency, ups28BypassNumLines,
|
|
ups28BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 5 }
|
|
|
|
ups28BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups28AlarmsPresent, ups28AlarmDescr, ups28AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups28BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 6 }
|
|
|
|
ups28BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups28TestId, ups28TestSpinLock,
|
|
ups28TestResultsSummary, ups28TestResultsDetail,
|
|
ups28TestStartTime, ups28TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 7 }
|
|
|
|
ups28BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups28ShutdownType, ups28ShutdownAfterDelay,
|
|
ups28StartupAfterDelay, ups28RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups28BasicGroups 8 }
|
|
|
|
ups28FullGroups OBJECT IDENTIFIER ::= { ups28Groups 3 }
|
|
|
|
ups28FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups28IdentManufacturer, ups28IdentModel,
|
|
ups28IdentUPSSoftwareVersion,
|
|
ups28IdentAgentSoftwareVersion, ups28IdentName,
|
|
ups28IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups28FullGroups 1 }
|
|
|
|
ups28FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups28BatteryStatus, ups28SecondsOnBattery,
|
|
ups28EstimatedMinutesRemaining,
|
|
ups28EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 2 }
|
|
|
|
ups28FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups28InputLineBads, ups28InputNumLines,
|
|
ups28InputFrequency, ups28InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 3 }
|
|
|
|
ups28FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups28OutputSource, ups28OutputFrequency,
|
|
ups28OutputNumLines, ups28OutputVoltage,
|
|
ups28OutputCurrent, ups28OutputPower,
|
|
ups28OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 4 }
|
|
|
|
ups28FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups28BypassFrequency, ups28BypassNumLines,
|
|
ups28BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 5 }
|
|
|
|
ups28FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups28AlarmsPresent, ups28AlarmDescr, ups28AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups28FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 6 }
|
|
|
|
ups28FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups28TestId, ups28TestSpinLock,
|
|
ups28TestResultsSummary, ups28TestResultsDetail,
|
|
ups28TestStartTime, ups28TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 7 }
|
|
|
|
ups28FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups28ShutdownType, ups28ShutdownAfterDelay,
|
|
ups28StartupAfterDelay, ups28RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups28FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups28FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 29 data
|
|
--
|
|
|
|
upsModule29 OBJECT IDENTIFIER ::= { upsModular 30 }
|
|
ups29Objects OBJECT IDENTIFIER ::= { upsModule29 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups29IdentName and
|
|
-- ups29IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups29Ident OBJECT IDENTIFIER ::= { ups29Objects 1 }
|
|
|
|
ups29IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups29Ident 1 }
|
|
|
|
ups29IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups29Ident 2 }
|
|
|
|
ups29IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups29IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups29Ident 3 }
|
|
|
|
ups29IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups29IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups29Ident 4 }
|
|
|
|
ups29IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups29Ident 5 }
|
|
|
|
ups29IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups29Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups29Battery OBJECT IDENTIFIER ::= { ups29Objects 2 }
|
|
|
|
ups29BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups29ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups29ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups29Battery 1 }
|
|
|
|
ups29SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups29Battery 2 }
|
|
|
|
ups29EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups29Battery 3 }
|
|
|
|
ups29EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups29Battery 4 }
|
|
|
|
ups29BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups29Battery 5 }
|
|
|
|
ups29BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups29Battery 6 }
|
|
|
|
ups29BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups29Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups29Input OBJECT IDENTIFIER ::= { ups29Objects 3 }
|
|
|
|
ups29InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups29Input 1 }
|
|
|
|
|
|
ups29InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups29Input 2 }
|
|
|
|
ups29InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups29InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups29InputNumLines."
|
|
::= { ups29Input 3 }
|
|
|
|
ups29InputEntry OBJECT-TYPE
|
|
SYNTAX Ups29InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups29InputLineIndex }
|
|
::= { ups29InputTable 1 }
|
|
|
|
Ups29InputEntry ::= SEQUENCE {
|
|
ups29InputLineIndex PositiveInteger,
|
|
ups29InputFrequency NonNegativeInteger,
|
|
ups29InputVoltage NonNegativeInteger,
|
|
ups29InputCurrent NonNegativeInteger,
|
|
ups29InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups29InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups29InputEntry 1 }
|
|
|
|
ups29InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups29InputEntry 2 }
|
|
|
|
ups29InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups29InputEntry 3 }
|
|
|
|
ups29InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups29InputEntry 4 }
|
|
|
|
ups29InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups29InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups29Output OBJECT IDENTIFIER ::= { ups29Objects 4 }
|
|
|
|
ups29OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups29Output 1 }
|
|
|
|
ups29OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups29Output 2 }
|
|
|
|
ups29OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups29Output 3 }
|
|
|
|
ups29OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups29OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups29OutputNumLines."
|
|
::= { ups29Output 4 }
|
|
|
|
ups29OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups29OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups29OutputLineIndex }
|
|
::= { ups29OutputTable 1 }
|
|
|
|
Ups29OutputEntry ::= SEQUENCE {
|
|
ups29OutputLineIndex PositiveInteger,
|
|
ups29OutputVoltage NonNegativeInteger,
|
|
ups29OutputCurrent NonNegativeInteger,
|
|
ups29OutputPower NonNegativeInteger,
|
|
ups29OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups29OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups29OutputEntry 1 }
|
|
|
|
ups29OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups29OutputEntry 2 }
|
|
|
|
ups29OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups29OutputEntry 3 }
|
|
|
|
ups29OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups29OutputEntry 4 }
|
|
|
|
ups29OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups29OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups29Bypass OBJECT IDENTIFIER ::= { ups29Objects 5 }
|
|
|
|
ups29BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups29Bypass 1 }
|
|
|
|
ups29BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups29Bypass 2 }
|
|
|
|
ups29BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups29BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups29BypassNumLines."
|
|
::= { ups29Bypass 3 }
|
|
|
|
ups29BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups29BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups29BypassLineIndex }
|
|
::= { ups29BypassTable 1 }
|
|
|
|
Ups29BypassEntry ::= SEQUENCE {
|
|
ups29BypassLineIndex PositiveInteger,
|
|
ups29BypassVoltage NonNegativeInteger,
|
|
ups29BypassCurrent NonNegativeInteger,
|
|
ups29BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups29BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups29BypassEntry 1 }
|
|
|
|
ups29BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups29BypassEntry 2 }
|
|
|
|
ups29BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups29BypassEntry 3 }
|
|
|
|
ups29BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups29BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups29Alarm OBJECT IDENTIFIER ::= { ups29Objects 6 }
|
|
|
|
ups29AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups29Alarm 1 }
|
|
|
|
ups29AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups29AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups29AlarmId equal to 1, and increments the value of
|
|
ups29AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups29AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups29AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups29AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups29AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups29AlarmsPresent."
|
|
::= { ups29Alarm 2 }
|
|
|
|
ups29AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups29AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups29AlarmId }
|
|
::= { ups29AlarmTable 1 }
|
|
|
|
Ups29AlarmEntry ::= SEQUENCE {
|
|
ups29AlarmId PositiveInteger,
|
|
ups29AlarmDescr AutonomousType,
|
|
ups29AlarmTime TimeStamp
|
|
}
|
|
|
|
ups29AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups29AlarmEntry 1 }
|
|
|
|
ups29AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups29AlarmEntry 2 }
|
|
|
|
ups29AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups29AlarmTime shall equal
|
|
0."
|
|
::= { ups29AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups29WellKnownAlarms OBJECT IDENTIFIER ::= { ups29Alarm 3 }
|
|
ups29AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups29WellKnownAlarms 1 }
|
|
|
|
ups29AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups29WellKnownAlarms 2 }
|
|
|
|
ups29AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups29ConfigLowBattTime."
|
|
::= { ups29WellKnownAlarms 3 }
|
|
|
|
|
|
ups29AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups29WellKnownAlarms 4 }
|
|
|
|
ups29AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups29WellKnownAlarms 5 }
|
|
|
|
ups29AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups29WellKnownAlarms 6 }
|
|
|
|
ups29AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups29WellKnownAlarms 7 }
|
|
|
|
ups29AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups29WellKnownAlarms 8 }
|
|
|
|
ups29AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups29WellKnownAlarms 9 }
|
|
|
|
ups29AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups29WellKnownAlarms 10 }
|
|
|
|
ups29AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups29WellKnownAlarms 11 }
|
|
|
|
ups29AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups29WellKnownAlarms 12 }
|
|
|
|
ups29AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups29WellKnownAlarms 13 }
|
|
|
|
ups29AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups29WellKnownAlarms 14 }
|
|
|
|
ups29AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups29WellKnownAlarms 15 }
|
|
|
|
ups29AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups29WellKnownAlarms 16 }
|
|
|
|
ups29AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups29WellKnownAlarms 17 }
|
|
|
|
ups29AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups29WellKnownAlarms 18 }
|
|
|
|
ups29AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups29WellKnownAlarms 19 }
|
|
|
|
ups29AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups29WellKnownAlarms 20 }
|
|
|
|
ups29AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups29WellKnownAlarms 21 }
|
|
|
|
ups29AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups29ShutdownAfterDelay countdown is underway."
|
|
::= { ups29WellKnownAlarms 22 }
|
|
|
|
ups29AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups29WellKnownAlarms 23 }
|
|
|
|
ups29AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups29WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups29Test OBJECT IDENTIFIER ::= { ups29Objects 7 }
|
|
|
|
ups29TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups29TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups29TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups29TestId variable to
|
|
ups29TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups29TestNoTestsInitiated is returned."
|
|
::= { ups29Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups29TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups29TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups29TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups29TestResultsSummary */
|
|
get (upsTestSpinLock, ups29TestResultsSummary,
|
|
ups29TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups29TestResultsSummary,
|
|
ups29TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups29TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups29TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups29Test 2 }
|
|
|
|
ups29TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups29TestId to ups29TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups29Test 3 }
|
|
|
|
ups29TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups29TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups29Test 4 }
|
|
|
|
ups29TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups29TestResultsSummary is noTestsInitiated(6),
|
|
ups29TestStartTime has the value 0."
|
|
::= { ups29Test 5 }
|
|
|
|
ups29TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups29TestResultsSummary is noTestsInitiated(6),
|
|
ups29TestElapsedTime has the value 0."
|
|
::= { ups29Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups29WellKnownTests OBJECT IDENTIFIER ::= { ups29Test 7 }
|
|
|
|
|
|
ups29TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups29WellKnownTests 1 }
|
|
|
|
ups29TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups29WellKnownTests 2 }
|
|
|
|
ups29TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups29WellKnownTests 3 }
|
|
|
|
ups29TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups29WellKnownTests 4 }
|
|
|
|
ups29TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups29WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups29Control OBJECT IDENTIFIER ::= { ups29Objects 8 }
|
|
|
|
ups29ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups29ShutdownAfterDelay and ups29RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups29Control 1 }
|
|
|
|
ups29ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups29ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups29ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups29ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups29ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups29ShutdownAfterDelay already in effect."
|
|
::= { ups29Control 2 }
|
|
|
|
ups29StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups29StartupAfterDelay
|
|
countdown or ups29RebootWithDuration countdown in
|
|
progress. When read, ups29StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups29Control 3 }
|
|
|
|
ups29RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups29ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups29RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups29Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups29Traps OBJECT IDENTIFIER ::= { upsModule29 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups29TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups29EstimatedMinutesRemaining, ups29SecondsOnBattery,
|
|
ups29ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups29Traps 1 }
|
|
|
|
ups29TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups29TestId, ups29TestSpinLock,
|
|
ups29TestResultsSummary, ups29TestResultsDetail,
|
|
ups29TestStartTime, ups29TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups29Traps 2 }
|
|
|
|
ups29TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups29AlarmId, ups29AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups29AlarmOnBattery and
|
|
ups29AlarmTestInProgress."
|
|
::= { ups29Traps 3 }
|
|
|
|
ups29TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups29AlarmId, ups29AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups29AlarmTestInProgress."
|
|
::= { ups29Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups29Conformance OBJECT IDENTIFIER ::= { upsModule29 3 }
|
|
|
|
ups29Compliances OBJECT IDENTIFIER ::= { ups29Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups29SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups29SubsetIdentGroup,
|
|
ups29SubsetBatteryGroup, ups29SubsetInputGroup,
|
|
ups29SubsetOutputGroup, ups29SubsetAlarmGroup,
|
|
ups29SubsetControlGroup }
|
|
|
|
OBJECT ups29BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups29AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups29AlarmOnBattery, ups29AlarmLowBattery,
|
|
ups29AlarmInputBad, ups29AlarmUpsOutputOff,
|
|
ups29AlarmUpsSystemOff, and ups29AlarmTestInProgress."
|
|
|
|
OBJECT ups29OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups29ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups29Compliances 1 }
|
|
|
|
ups29BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups29BasicIdentGroup,
|
|
ups29BasicBatteryGroup, ups29BasicInputGroup,
|
|
ups29BasicOutputGroup, ups29BasicAlarmGroup,
|
|
ups29BasicTestGroup, ups29BasicControlGroup }
|
|
|
|
OBJECT ups29AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups29AlarmOnBattery, ups29AlarmLowBattery,
|
|
ups29AlarmDepletedBattery, ups29AlarmTempBad,
|
|
ups29AlarmInputBad, ups29AlarmOutputOverload,
|
|
ups29AlarmOnBypass, ups29AlarmBypassBad,
|
|
ups29AlarmOutputOffAsRequested,
|
|
ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff,
|
|
ups29AlarmUpsSystemOff, ups29AlarmGeneralFault,
|
|
ups29AlarmDiagnosticTestFailed,
|
|
ups29AlarmCommunicationsLost, ups29AlarmShutdownPending,
|
|
and ups29AlarmTestInProgress."
|
|
|
|
OBJECT ups29TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups29TestNoTestsInitiated."
|
|
|
|
OBJECT ups29OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups29BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups29BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups29ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups29Compliances 2 }
|
|
|
|
ups29FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups29FullIdentGroup, ups29FullBatteryGroup,
|
|
ups29FullInputGroup, ups29FullOutputGroup,
|
|
ups29FullAlarmGroup, ups29FullTestGroup,
|
|
ups29FullControlGroup }
|
|
|
|
OBJECT ups29AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups29AlarmBatteryBad, ups29AlarmOnBattery,
|
|
ups29AlarmLowBattery, ups29AlarmDepletedBattery,
|
|
ups29AlarmTempBad, ups29AlarmInputBad, ups29AlarmOnBypass,
|
|
ups29AlarmBypassBad, ups29AlarmOutputOffAsRequested,
|
|
ups29AlarmUpsOffAsRequested, ups29AlarmUpsOutputOff,
|
|
ups29AlarmUpsSystemOff, ups29AlarmGeneralFault,
|
|
ups29AlarmDiagnosticTestFailed,
|
|
ups29AlarmCommunicationsLost, ups29AlarmShutdownPending,
|
|
and ups29AlarmTestInProgress."
|
|
|
|
OBJECT ups29TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups29TestNoTestsInitiated,
|
|
ups29TestGeneralSystemsTest, and
|
|
ups29TestQuickBatteryTest."
|
|
|
|
OBJECT ups29OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups29FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups29FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups29ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups29Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups29Groups OBJECT IDENTIFIER ::= { ups29Conformance 2 }
|
|
|
|
ups29SubsetGroups OBJECT IDENTIFIER ::= { ups29Groups 1 }
|
|
|
|
ups29SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups29IdentManufacturer, ups29IdentModel,
|
|
ups29IdentAgentSoftwareVersion, ups29IdentName,
|
|
ups29IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups29SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups29SubsetGroups 1 }
|
|
|
|
ups29SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups29BatteryStatus, ups29SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups29SubsetGroups 2 }
|
|
|
|
ups29SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups29InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups29SubsetGroups 3 }
|
|
|
|
ups29SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups29OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups29SubsetGroups 4 }
|
|
|
|
|
|
-- { ups29SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups29SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups29AlarmsPresent, ups29AlarmDescr, ups29AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups29SubsetGroups 6 }
|
|
|
|
-- { ups29SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups29SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups29ShutdownType, ups29ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups29SubsetGroups 8 }
|
|
|
|
ups29BasicGroups OBJECT IDENTIFIER ::= { ups29Groups 2 }
|
|
|
|
ups29BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups29IdentManufacturer, ups29IdentModel,
|
|
ups29IdentUPSSoftwareVersion,
|
|
ups29IdentAgentSoftwareVersion, ups29IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 1 }
|
|
|
|
ups29BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups29BatteryStatus, ups29SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 2 }
|
|
|
|
ups29BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups29InputLineBads, ups29InputNumLines,
|
|
ups29InputFrequency, ups29InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 3 }
|
|
|
|
ups29BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups29OutputSource, ups29OutputFrequency,
|
|
ups29OutputNumLines, ups29OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 4 }
|
|
|
|
ups29BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups29BypassFrequency, ups29BypassNumLines,
|
|
ups29BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 5 }
|
|
|
|
ups29BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups29AlarmsPresent, ups29AlarmDescr, ups29AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups29BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 6 }
|
|
|
|
ups29BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups29TestId, ups29TestSpinLock,
|
|
ups29TestResultsSummary, ups29TestResultsDetail,
|
|
ups29TestStartTime, ups29TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 7 }
|
|
|
|
ups29BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups29ShutdownType, ups29ShutdownAfterDelay,
|
|
ups29StartupAfterDelay, ups29RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups29BasicGroups 8 }
|
|
|
|
ups29FullGroups OBJECT IDENTIFIER ::= { ups29Groups 3 }
|
|
|
|
ups29FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups29IdentManufacturer, ups29IdentModel,
|
|
ups29IdentUPSSoftwareVersion,
|
|
ups29IdentAgentSoftwareVersion, ups29IdentName,
|
|
ups29IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups29FullGroups 1 }
|
|
|
|
ups29FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups29BatteryStatus, ups29SecondsOnBattery,
|
|
ups29EstimatedMinutesRemaining,
|
|
ups29EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 2 }
|
|
|
|
ups29FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups29InputLineBads, ups29InputNumLines,
|
|
ups29InputFrequency, ups29InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 3 }
|
|
|
|
ups29FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups29OutputSource, ups29OutputFrequency,
|
|
ups29OutputNumLines, ups29OutputVoltage,
|
|
ups29OutputCurrent, ups29OutputPower,
|
|
ups29OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 4 }
|
|
|
|
ups29FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups29BypassFrequency, ups29BypassNumLines,
|
|
ups29BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 5 }
|
|
|
|
ups29FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups29AlarmsPresent, ups29AlarmDescr, ups29AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups29FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 6 }
|
|
|
|
ups29FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups29TestId, ups29TestSpinLock,
|
|
ups29TestResultsSummary, ups29TestResultsDetail,
|
|
ups29TestStartTime, ups29TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 7 }
|
|
|
|
ups29FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups29ShutdownType, ups29ShutdownAfterDelay,
|
|
ups29StartupAfterDelay, ups29RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups29FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups29FullGroups 8 }
|
|
|
|
|
|
--*******************************************************************
|
|
--
|
|
-- Module 30 data
|
|
--
|
|
|
|
upsModule30 OBJECT IDENTIFIER ::= { upsModular 31 }
|
|
ups30Objects OBJECT IDENTIFIER ::= { upsModule30 1 }
|
|
|
|
--
|
|
-- The Device Identification group.
|
|
-- All objects in this group except for ups30IdentName and
|
|
-- ups30IdentAttachedDevices are set at device initialization
|
|
-- and remain static.
|
|
--
|
|
|
|
ups30Ident OBJECT IDENTIFIER ::= { ups30Objects 1 }
|
|
|
|
ups30IdentManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the UPS manufacturer."
|
|
::= { ups30Ident 1 }
|
|
|
|
ups30IdentModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS Model designation."
|
|
::= { ups30Ident 2 }
|
|
|
|
ups30IdentUPSSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS firmware/software version(s). This variable
|
|
may or may not have the same value as
|
|
ups30IdentAgentSoftwareVersion in some implementations."
|
|
::= { ups30Ident 3 }
|
|
|
|
ups30IdentAgentSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS agent software version. This variable may or
|
|
may not have the same value as
|
|
ups30IdentUPSSoftwareVersion in some implementations."
|
|
::= { ups30Ident 4 }
|
|
|
|
ups30IdentName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the UPS. This object should be
|
|
set by the administrator."
|
|
::= { ups30Ident 5 }
|
|
|
|
ups30IdentAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string identifying the devices attached to the
|
|
output(s) of the UPS. This object should be set by
|
|
the administrator."
|
|
::= { ups30Ident 6 }
|
|
|
|
|
|
--
|
|
-- Battery Group
|
|
--
|
|
|
|
ups30Battery OBJECT IDENTIFIER ::= { ups30Objects 2 }
|
|
|
|
ups30BatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
batteryNormal(2),
|
|
batteryLow(3),
|
|
batteryDepleted(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The indication of the capacity remaining in the UPS
|
|
system's batteries. A value of batteryNormal
|
|
indicates that the remaining run-time is greater than
|
|
ups30ConfigLowBattTime. A value of batteryLow indicates
|
|
that the remaining battery run-time is less than or
|
|
equal to ups30ConfigLowBattTime. A value of
|
|
batteryDepleted indicates that the UPS will be unable
|
|
to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the
|
|
utility power is currently absent and the UPS is
|
|
unable to sustain the output)."
|
|
::= { ups30Battery 1 }
|
|
|
|
ups30SecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. Zero shall be returned
|
|
if the unit is not on battery power."
|
|
::= { ups30Battery 2 }
|
|
|
|
ups30EstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { ups30Battery 3 }
|
|
|
|
ups30EstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge."
|
|
::= { ups30Battery 4 }
|
|
|
|
ups30BatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Volt DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present battery voltage."
|
|
::= { ups30Battery 5 }
|
|
|
|
ups30BatteryCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 Amp DC"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery current."
|
|
::= { ups30Battery 6 }
|
|
|
|
ups30BatteryTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ambient temperature at or near the UPS Battery
|
|
casing."
|
|
::= { ups30Battery 7 }
|
|
|
|
|
|
--
|
|
-- Input Group
|
|
--
|
|
|
|
ups30Input OBJECT IDENTIFIER ::= { ups30Objects 3 }
|
|
|
|
ups30InputLineBads OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of the number of times the input entered an
|
|
out-of-tolerance condition as defined by the
|
|
manufacturer. This count is incremented by one each
|
|
time the input transitions from zero out-of-tolerance
|
|
lines to one or more input lines out-of-tolerance."
|
|
::= { ups30Input 1 }
|
|
|
|
|
|
ups30InputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of input lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
input table."
|
|
::= { ups30Input 2 }
|
|
|
|
ups30InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups30InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of input table entries. The number of entries
|
|
is given by the value of ups30InputNumLines."
|
|
::= { ups30Input 3 }
|
|
|
|
ups30InputEntry OBJECT-TYPE
|
|
SYNTAX Ups30InputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular input line."
|
|
INDEX { ups30InputLineIndex }
|
|
::= { ups30InputTable 1 }
|
|
|
|
Ups30InputEntry ::= SEQUENCE {
|
|
ups30InputLineIndex PositiveInteger,
|
|
ups30InputFrequency NonNegativeInteger,
|
|
ups30InputVoltage NonNegativeInteger,
|
|
ups30InputCurrent NonNegativeInteger,
|
|
ups30InputTruePower NonNegativeInteger
|
|
}
|
|
|
|
ups30InputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The input line identifier."
|
|
::= { ups30InputEntry 1 }
|
|
|
|
ups30InputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present input frequency."
|
|
::= { ups30InputEntry 2 }
|
|
|
|
ups30InputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input voltage."
|
|
::= { ups30InputEntry 3 }
|
|
|
|
ups30InputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input current."
|
|
::= { ups30InputEntry 4 }
|
|
|
|
ups30InputTruePower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of the present input true power."
|
|
::= { ups30InputEntry 5 }
|
|
|
|
|
|
--
|
|
-- The Output group.
|
|
--
|
|
|
|
ups30Output OBJECT IDENTIFIER ::= { ups30Objects 4 }
|
|
|
|
ups30OutputSource OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
none(2),
|
|
normal(3),
|
|
bypass(4),
|
|
battery(5),
|
|
booster(6),
|
|
reducer(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present source of output power. The enumeration
|
|
none(2) indicates that there is no source of output
|
|
power (and therefore no output power), for example,
|
|
the system has opened the output breaker."
|
|
::= { ups30Output 1 }
|
|
|
|
ups30OutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output frequency."
|
|
::= { ups30Output 2 }
|
|
|
|
ups30OutputNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of output lines utilized in this device.
|
|
This variable indicates the number of rows in the
|
|
output table."
|
|
::= { ups30Output 3 }
|
|
|
|
ups30OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups30OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of output table entries. The number of
|
|
entries is given by the value of ups30OutputNumLines."
|
|
::= { ups30Output 4 }
|
|
|
|
ups30OutputEntry OBJECT-TYPE
|
|
SYNTAX Ups30OutputEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular output line."
|
|
INDEX { ups30OutputLineIndex }
|
|
::= { ups30OutputTable 1 }
|
|
|
|
Ups30OutputEntry ::= SEQUENCE {
|
|
ups30OutputLineIndex PositiveInteger,
|
|
ups30OutputVoltage NonNegativeInteger,
|
|
ups30OutputCurrent NonNegativeInteger,
|
|
ups30OutputPower NonNegativeInteger,
|
|
ups30OutputPercentLoad INTEGER
|
|
}
|
|
|
|
ups30OutputLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output line identifier."
|
|
::= { ups30OutputEntry 1 }
|
|
|
|
ups30OutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output voltage."
|
|
::= { ups30OutputEntry 2 }
|
|
|
|
ups30OutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output current."
|
|
::= { ups30OutputEntry 3 }
|
|
|
|
ups30OutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present output true power."
|
|
::= { ups30OutputEntry 4 }
|
|
|
|
ups30OutputPercentLoad OBJECT-TYPE
|
|
SYNTAX Integer32 (0..200)
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The percentage of the UPS power capacity presently
|
|
being used on this output line, i.e., the greater of
|
|
the percent load of true power capacity and the
|
|
percent load of VA."
|
|
::= { ups30OutputEntry 5 }
|
|
|
|
--
|
|
-- The Bypass group.
|
|
--
|
|
|
|
ups30Bypass OBJECT IDENTIFIER ::= { ups30Objects 5 }
|
|
|
|
ups30BypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 Hertz"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass frequency."
|
|
::= { ups30Bypass 1 }
|
|
|
|
ups30BypassNumLines OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of bypass lines utilized in this device.
|
|
This entry indicates the number of rows in the bypass
|
|
table."
|
|
::= { ups30Bypass 2 }
|
|
|
|
ups30BypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups30BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of bypass table entries. The number of
|
|
entries is given by the value of ups30BypassNumLines."
|
|
::= { ups30Bypass 3 }
|
|
|
|
ups30BypassEntry OBJECT-TYPE
|
|
SYNTAX Ups30BypassEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular bypass input."
|
|
INDEX { ups30BypassLineIndex }
|
|
::= { ups30BypassTable 1 }
|
|
|
|
Ups30BypassEntry ::= SEQUENCE {
|
|
ups30BypassLineIndex PositiveInteger,
|
|
ups30BypassVoltage NonNegativeInteger,
|
|
ups30BypassCurrent NonNegativeInteger,
|
|
ups30BypassPower NonNegativeInteger
|
|
}
|
|
|
|
ups30BypassLineIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The bypass line identifier."
|
|
::= { ups30BypassEntry 1 }
|
|
|
|
ups30BypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "RMS Volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass voltage."
|
|
::= { ups30BypassEntry 2 }
|
|
|
|
ups30BypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "0.1 RMS Amp"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present bypass current."
|
|
::= { ups30BypassEntry 3 }
|
|
|
|
ups30BypassPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present true power conveyed by the bypass."
|
|
::= { ups30BypassEntry 4 }
|
|
|
|
|
|
--
|
|
-- The Alarm group.
|
|
--
|
|
|
|
ups30Alarm OBJECT IDENTIFIER ::= { ups30Objects 6 }
|
|
|
|
ups30AlarmsPresent OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present number of active alarm conditions."
|
|
::= { ups30Alarm 1 }
|
|
|
|
ups30AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Ups30AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm table entries. The table contains
|
|
zero, one, or many rows at any moment, depending upon
|
|
the number of alarm conditions in effect. The table
|
|
is initially empty at agent startup. The agent
|
|
creates a row in the table each time a condition is
|
|
detected and deletes that row when that condition no
|
|
longer pertains. The agent creates the first row with
|
|
ups30AlarmId equal to 1, and increments the value of
|
|
ups30AlarmId each time a new row is created, wrapping to
|
|
the first free value greater than or equal to 1 when
|
|
the maximum value of ups30AlarmId would otherwise be
|
|
exceeded. Consequently, after multiple operations,
|
|
the table may become sparse, e.g., containing entries
|
|
for rows 95, 100, 101, and 203 and the entries should
|
|
not be assumed to be in chronological order because
|
|
ups30AlarmId might have wrapped.
|
|
|
|
Alarms are named by an AutonomousType (OBJECT
|
|
IDENTIFIER), ups30AlarmDescr, to allow a single table to
|
|
reflect well known alarms plus alarms defined by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device. No
|
|
two rows will have the same value of ups30AlarmDescr,
|
|
since alarms define conditions. In order to meet this
|
|
requirement, care should be taken in the definition of
|
|
alarm conditions to insure that a system cannot enter
|
|
the same condition multiple times simultaneously.
|
|
|
|
The number of rows in the table at any given time is
|
|
reflected by the value of ups30AlarmsPresent."
|
|
::= { ups30Alarm 2 }
|
|
|
|
ups30AlarmEntry OBJECT-TYPE
|
|
SYNTAX Ups30AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a
|
|
particular alarm."
|
|
INDEX { ups30AlarmId }
|
|
::= { ups30AlarmTable 1 }
|
|
|
|
Ups30AlarmEntry ::= SEQUENCE {
|
|
ups30AlarmId PositiveInteger,
|
|
ups30AlarmDescr AutonomousType,
|
|
ups30AlarmTime TimeStamp
|
|
}
|
|
|
|
ups30AlarmId OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier for an alarm condition. This
|
|
value must remain constant."
|
|
::= { ups30AlarmEntry 1 }
|
|
|
|
ups30AlarmDescr OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reference to an alarm description object. The
|
|
object referenced should not be accessible, but rather
|
|
be used to provide a unique description of the alarm
|
|
condition."
|
|
::= { ups30AlarmEntry 2 }
|
|
|
|
ups30AlarmTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the alarm condition was
|
|
detected. If the alarm condition was detected at the
|
|
time of agent startup and presumably existed before
|
|
agent startup, the value of ups30AlarmTime shall equal
|
|
0."
|
|
::= { ups30AlarmEntry 3 }
|
|
|
|
|
|
--
|
|
-- Well known alarm conditions.
|
|
--
|
|
|
|
ups30WellKnownAlarms OBJECT IDENTIFIER ::= { ups30Alarm 3 }
|
|
ups30AlarmBatteryBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more batteries have been determined to require
|
|
replacement."
|
|
::= { ups30WellKnownAlarms 1 }
|
|
|
|
ups30AlarmOnBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is drawing power from the batteries."
|
|
::= { ups30WellKnownAlarms 2 }
|
|
|
|
ups30AlarmLowBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining battery run-time is less than or equal
|
|
to ups30ConfigLowBattTime."
|
|
::= { ups30WellKnownAlarms 3 }
|
|
|
|
|
|
ups30AlarmDepletedBattery OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will be unable to sustain the present load
|
|
when and if the utility power is lost."
|
|
::= { ups30WellKnownAlarms 4 }
|
|
|
|
ups30AlarmTempBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A temperature is out of tolerance."
|
|
::= { ups30WellKnownAlarms 5 }
|
|
|
|
ups30AlarmInputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An input condition is out of tolerance."
|
|
::= { ups30WellKnownAlarms 6 }
|
|
|
|
ups30AlarmOutputBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An output condition (other than OutputOverload) is
|
|
out of tolerance."
|
|
::= { ups30WellKnownAlarms 7 }
|
|
|
|
ups30AlarmOutputOverload OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output load exceeds the UPS output capacity."
|
|
::= { ups30WellKnownAlarms 8 }
|
|
|
|
ups30AlarmOnBypass OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is presently engaged on the UPS."
|
|
::= { ups30WellKnownAlarms 9 }
|
|
|
|
ups30AlarmBypassBad OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Bypass is out of tolerance."
|
|
::= { ups30WellKnownAlarms 10 }
|
|
|
|
ups30AlarmOutputOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS has shutdown as requested, i.e., the output
|
|
is off."
|
|
::= { ups30WellKnownAlarms 11 }
|
|
|
|
ups30AlarmUpsOffAsRequested OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entire UPS has shutdown as commanded."
|
|
::= { ups30WellKnownAlarms 12 }
|
|
|
|
ups30AlarmChargerFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An uncorrected problem has been detected within the
|
|
UPS charger subsystem."
|
|
::= { ups30WellKnownAlarms 13 }
|
|
|
|
ups30AlarmUpsOutputOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The output of the UPS is in the off state."
|
|
::= { ups30WellKnownAlarms 14 }
|
|
|
|
ups30AlarmUpsSystemOff OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS system is in the off state."
|
|
::= { ups30WellKnownAlarms 15 }
|
|
|
|
ups30AlarmFanFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fans in the UPS has been
|
|
detected."
|
|
::= { ups30WellKnownAlarms 16 }
|
|
|
|
ups30AlarmFuseFailure OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failure of one or more fuses has been detected."
|
|
::= { ups30WellKnownAlarms 17 }
|
|
|
|
ups30AlarmGeneralFault OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A general fault in the UPS has been detected."
|
|
::= { ups30WellKnownAlarms 18 }
|
|
|
|
ups30AlarmDiagnosticTestFailed OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the last diagnostic test indicates a
|
|
failure."
|
|
::= { ups30WellKnownAlarms 19 }
|
|
|
|
ups30AlarmCommunicationsLost OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A problem has been encountered in the communications
|
|
between the agent and the UPS."
|
|
::= { ups30WellKnownAlarms 20 }
|
|
|
|
ups30AlarmAwaitingPower OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS output is off and the UPS is awaiting the
|
|
return of input power."
|
|
::= { ups30WellKnownAlarms 21 }
|
|
|
|
ups30AlarmShutdownPending OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A ups30ShutdownAfterDelay countdown is underway."
|
|
::= { ups30WellKnownAlarms 22 }
|
|
|
|
ups30AlarmShutdownImminent OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS will turn off power to the load in less than
|
|
5 seconds; this may be either a timed shutdown or a
|
|
low battery shutdown."
|
|
::= { ups30WellKnownAlarms 23 }
|
|
|
|
ups30AlarmTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test is in progress, as initiated and indicated by
|
|
the Test Group. Tests initiated via other
|
|
implementation-specific mechanisms can indicate the
|
|
presence of the testing in the alarm table, if
|
|
desired, via a OBJECT-IDENTITY macro in the MIB
|
|
document specific to that implementation and are
|
|
outside the scope of this OBJECT-IDENTITY."
|
|
::= { ups30WellKnownAlarms 24 }
|
|
|
|
|
|
--
|
|
-- The Test Group
|
|
--
|
|
|
|
ups30Test OBJECT IDENTIFIER ::= { ups30Objects 7 }
|
|
|
|
ups30TestId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is named by an OBJECT IDENTIFIER which
|
|
allows a standard mechanism for the initiation of
|
|
tests, including the well known tests identified in
|
|
this document as well as those introduced by a
|
|
particular implementation, i.e., as documented in the
|
|
private enterprise MIB definition for the device.
|
|
|
|
Setting this variable initiates the named test. Sets
|
|
to this variable require the presence of
|
|
ups30TestSpinLock in the same SNMP message.
|
|
|
|
The set request will be rejected with an appropriate
|
|
error message if the requested test cannot be
|
|
performed, including attempts to start a test when
|
|
another test is already in progress. The status of
|
|
the current or last test is maintained in
|
|
ups30TestResultsSummary. Tests in progress may be
|
|
aborted by setting the ups30TestId variable to
|
|
ups30TestAbortTestInProgress.
|
|
|
|
Read operations return the value of the name of the
|
|
test in progress if a test is in progress or the name
|
|
of the last test performed if no test is in progress,
|
|
unless no test has been run, in which case the well
|
|
known value ups30TestNoTestsInitiated is returned."
|
|
::= { ups30Test 1 }
|
|
|
|
-- see [6] for more information on the semantics of objects with
|
|
-- syntax of TestAndIncr
|
|
|
|
ups30TestSpinLock OBJECT-TYPE
|
|
SYNTAX TestAndIncr
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A spin lock on the test subsystem. The spinlock is
|
|
used as follows.
|
|
|
|
Before starting a test, a manager-station should make
|
|
sure that a test is not in progress as follows:
|
|
|
|
try_again:
|
|
get (upsTestSpinLock)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
/* loop while a test is running for another
|
|
manager */
|
|
short delay
|
|
get (upsTestSpinLock)
|
|
}
|
|
lock_value = ups30TestSpinLock
|
|
/* no test in progress, start the test */
|
|
set (upsTestSpinLock = lock_value, ups30TestId =
|
|
requested_test)
|
|
if (error_index == 1) { /* (upsTestSpinLock
|
|
failed) */
|
|
/* if problem is not access control, then
|
|
some other manager slipped in ahead of us
|
|
*/
|
|
goto try_again
|
|
}
|
|
if (error_index == 2) { /* (upsTestId) */
|
|
/* cannot perform the test */
|
|
give up
|
|
}
|
|
/* test started ok */
|
|
/* wait for test completion by polling
|
|
|
|
ups30TestResultsSummary */
|
|
get (upsTestSpinLock, ups30TestResultsSummary,
|
|
ups30TestResultsDetail)
|
|
while (upsTestResultsSummary == inProgress) {
|
|
short delay
|
|
get (upsTestSpinLock, ups30TestResultsSummary,
|
|
ups30TestResultsDetail)
|
|
}
|
|
/* when test completes, retrieve any additional
|
|
test results */
|
|
/* if ups30TestSpinLock == lock_value + 1, then
|
|
these are our test */
|
|
/* results (as opposed to another manager's */
|
|
The initial value of ups30TestSpinLock at agent
|
|
initialization shall
|
|
be 1."
|
|
::= { ups30Test 2 }
|
|
|
|
ups30TestResultsSummary OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
donePass(1),
|
|
doneWarning(2),
|
|
doneError(3),
|
|
aborted(4),
|
|
inProgress(5),
|
|
noTestsInitiated(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The results of the current or last UPS diagnostics
|
|
test performed. The values for donePass(1),
|
|
doneWarning(2), and doneError(3) indicate that the
|
|
test completed either successfully, with a warning, or
|
|
with an error, respectively. The value aborted(4) is
|
|
returned for tests which are aborted by setting the
|
|
value of ups30TestId to ups30TestAbortTestInProgress.
|
|
Tests which have not yet concluded are indicated by
|
|
inProgress(5). The value noTestsInitiated(6)
|
|
indicates that no previous test results are available,
|
|
such as is the case when no tests have been run since
|
|
the last reinitialization of the network management
|
|
subsystem and the system has no provision for non-
|
|
volatile storage of test results."
|
|
::= { ups30Test 3 }
|
|
|
|
ups30TestResultsDetail OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information about ups30TestResultsSummary.
|
|
If no additional information available, a zero length
|
|
string is returned."
|
|
::= { ups30Test 4 }
|
|
|
|
ups30TestStartTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the time the previous test was initiated. If the
|
|
value of ups30TestResultsSummary is noTestsInitiated(6),
|
|
ups30TestStartTime has the value 0."
|
|
::= { ups30Test 5 }
|
|
|
|
ups30TestElapsedTime OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of time, in TimeTicks, since the test in
|
|
progress was initiated, or, if no test is in progress,
|
|
the previous test took to complete. If the value of
|
|
ups30TestResultsSummary is noTestsInitiated(6),
|
|
ups30TestElapsedTime has the value 0."
|
|
::= { ups30Test 6 }
|
|
|
|
--
|
|
-- Well known tests.
|
|
--
|
|
|
|
ups30WellKnownTests OBJECT IDENTIFIER ::= { ups30Test 7 }
|
|
|
|
|
|
ups30TestNoTestsInitiated OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No tests have been initiated and no test is in
|
|
progress."
|
|
::= { ups30WellKnownTests 1 }
|
|
|
|
ups30TestAbortTestInProgress OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test in progress is to be aborted / the test in
|
|
progress was aborted."
|
|
::= { ups30WellKnownTests 2 }
|
|
|
|
ups30TestGeneralSystemsTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The manufacturer's standard test of UPS device
|
|
systems."
|
|
::= { ups30WellKnownTests 3 }
|
|
|
|
ups30TestQuickBatteryTest OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A test that is sufficient to determine if the battery
|
|
needs replacement."
|
|
::= { ups30WellKnownTests 4 }
|
|
|
|
ups30TestDeepBatteryCalibration OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The system is placed on battery to a discharge level,
|
|
set by the manufacturer, sufficient to determine
|
|
battery replacement and battery run-time with a high
|
|
degree of confidence. WARNING: this test will leave
|
|
the battery in a low charge state and will require
|
|
time for recharging to a level sufficient to provide
|
|
normal battery duration for the protected load."
|
|
::= { ups30WellKnownTests 5 }
|
|
|
|
|
|
--
|
|
-- The Control group.
|
|
--
|
|
|
|
ups30Control OBJECT IDENTIFIER ::= { ups30Objects 8 }
|
|
|
|
ups30ShutdownType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
output(1),
|
|
system(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object determines the nature of the action to be
|
|
taken at the time when the countdown of the
|
|
ups30ShutdownAfterDelay and ups30RebootWithDuration
|
|
objects reaches zero.
|
|
|
|
Setting this object to output(1) indicates that
|
|
shutdown requests should cause only the output of the
|
|
UPS to turn off. Setting this object to system(2)
|
|
indicates that shutdown requests will cause the entire
|
|
UPS system to turn off."
|
|
::= { ups30Control 1 }
|
|
|
|
ups30ShutdownAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will shutdown (i.e., turn off)
|
|
either the UPS output or the UPS system (as determined
|
|
by the value of ups30ShutdownType at the time of
|
|
shutdown) after the indicated number of seconds, or
|
|
less if the UPS batteries become depleted. Setting
|
|
this object to 0 will cause the shutdown to occur
|
|
immediately. Setting this object to -1 will abort the
|
|
countdown. If the system is already in the desired
|
|
state at the time the countdown reaches 0, then
|
|
nothing will happen. That is, there is no additional
|
|
action at that time if ups30ShutdownType = system and
|
|
the system is already off. Similarly, there is no
|
|
additional action at that time if ups30ShutdownType =
|
|
output and the output is already off. When read,
|
|
ups30ShutdownAfterDelay will return the number of
|
|
seconds remaining until shutdown, or -1 if no shutdown
|
|
countdown is in effect. On some systems, if the agent
|
|
is restarted while a shutdown countdown is in effect,
|
|
the countdown may be aborted. Sets to this object
|
|
override any ups30ShutdownAfterDelay already in effect."
|
|
::= { ups30Control 2 }
|
|
|
|
ups30StartupAfterDelay OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will start the output after the
|
|
indicated number of seconds, including starting the
|
|
UPS, if necessary. Setting this object to 0 will
|
|
cause the startup to occur immediately. Setting this
|
|
object to -1 will abort the countdown. If the output
|
|
is already on at the time the countdown reaches 0,
|
|
then nothing will happen. Sets to this object
|
|
override the effect of any ups30StartupAfterDelay
|
|
countdown or ups30RebootWithDuration countdown in
|
|
progress. When read, ups30StartupAfterDelay will return
|
|
the number of seconds until startup, or -1 if no
|
|
startup countdown is in effect. If the countdown
|
|
expires during a utility failure, the startup shall
|
|
not occur until the utility power is restored. On
|
|
some systems, if the agent is restarted while a
|
|
startup countdown is in effect, the countdown is
|
|
aborted."
|
|
::= { ups30Control 3 }
|
|
|
|
ups30RebootWithDuration OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..300)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object will immediately shutdown (i.e.,
|
|
turn off) either the UPS output or the UPS system (as
|
|
determined by the value of ups30ShutdownType at the time
|
|
of shutdown) for a period equal to the indicated
|
|
number of seconds, after which time the output will be
|
|
started, including starting the UPS, if necessary. If
|
|
the number of seconds required to perform the request
|
|
is greater than the requested duration, then the
|
|
requested shutdown and startup cycle shall be
|
|
performed in the minimum time possible, but in no case
|
|
shall this require more than the requested duration
|
|
plus 60 seconds. When read, ups30RebootWithDuration
|
|
shall return the number of seconds remaining in the
|
|
countdown, or -1 if no countdown is in progress. If
|
|
the startup should occur during a utility failure, the
|
|
startup shall not occur until the utility power is
|
|
restored."
|
|
::= { ups30Control 4 }
|
|
|
|
|
|
--
|
|
-- notifications, i.e., traps
|
|
--
|
|
ups30Traps OBJECT IDENTIFIER ::= { upsModule30 2 }
|
|
|
|
-- This section defines the well-known notifications sent by
|
|
-- UPS agents.
|
|
-- Care must be taken to insure that no particular notification
|
|
-- is sent to a single receiving entity more often than once
|
|
-- every five seconds.
|
|
|
|
ups30TrapOnBattery NOTIFICATION-TYPE
|
|
OBJECTS { ups30EstimatedMinutesRemaining, ups30SecondsOnBattery,
|
|
ups30ConfigLowBattTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UPS is operating on battery power. This trap is
|
|
persistent and is resent at one minute intervals until
|
|
the UPS either turns off or is no longer running on
|
|
battery."
|
|
::= { ups30Traps 1 }
|
|
|
|
ups30TrapTestCompleted NOTIFICATION-TYPE
|
|
OBJECTS { ups30TestId, ups30TestSpinLock,
|
|
ups30TestResultsSummary, ups30TestResultsDetail,
|
|
ups30TestStartTime, ups30TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon completion of a UPS diagnostic
|
|
test."
|
|
::= { ups30Traps 2 }
|
|
|
|
ups30TrapAlarmEntryAdded NOTIFICATION-TYPE
|
|
OBJECTS { ups30AlarmId, ups30AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is inserted into
|
|
to the alarm table. It is sent on the insertion of
|
|
all alarms except for ups30AlarmOnBattery and
|
|
ups30AlarmTestInProgress."
|
|
::= { ups30Traps 3 }
|
|
|
|
ups30TrapAlarmEntryRemoved NOTIFICATION-TYPE
|
|
OBJECTS { ups30AlarmId, ups30AlarmDescr }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent each time an alarm is removed from
|
|
the alarm table. It is sent on the removal of all
|
|
alarms except for ups30AlarmTestInProgress."
|
|
::= { ups30Traps 4 }
|
|
|
|
|
|
--
|
|
-- conformance information
|
|
--
|
|
ups30Conformance OBJECT IDENTIFIER ::= { upsModule30 3 }
|
|
|
|
ups30Compliances OBJECT IDENTIFIER ::= { ups30Conformance 1 }
|
|
|
|
|
|
--
|
|
-- compliance statements
|
|
--
|
|
|
|
ups30SubsetCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that only support
|
|
the two-contact communication protocol."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups30SubsetIdentGroup,
|
|
ups30SubsetBatteryGroup, ups30SubsetInputGroup,
|
|
ups30SubsetOutputGroup, ups30SubsetAlarmGroup,
|
|
ups30SubsetControlGroup }
|
|
|
|
OBJECT ups30BatteryStatus
|
|
SYNTAX INTEGER {
|
|
batteryNormal(2),
|
|
batteryLow(3)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values unknown(1) and
|
|
batteryDepleted(4) is not required."
|
|
|
|
OBJECT ups30AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups30AlarmOnBattery, ups30AlarmLowBattery,
|
|
ups30AlarmInputBad, ups30AlarmUpsOutputOff,
|
|
ups30AlarmUpsSystemOff, and ups30AlarmTestInProgress."
|
|
|
|
OBJECT ups30OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(3),
|
|
battery(5)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
OBJECT ups30ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups30Compliances 1 }
|
|
|
|
ups30BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The compliance statement for UPSs that support
|
|
full-featured functions, such as control."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups30BasicIdentGroup,
|
|
ups30BasicBatteryGroup, ups30BasicInputGroup,
|
|
ups30BasicOutputGroup, ups30BasicAlarmGroup,
|
|
ups30BasicTestGroup, ups30BasicControlGroup }
|
|
|
|
OBJECT ups30AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups30AlarmOnBattery, ups30AlarmLowBattery,
|
|
ups30AlarmDepletedBattery, ups30AlarmTempBad,
|
|
ups30AlarmInputBad, ups30AlarmOutputOverload,
|
|
ups30AlarmOnBypass, ups30AlarmBypassBad,
|
|
ups30AlarmOutputOffAsRequested,
|
|
ups30AlarmUpsOffAsRequested, ups30AlarmUpsOutputOff,
|
|
ups30AlarmUpsSystemOff, ups30AlarmGeneralFault,
|
|
ups30AlarmDiagnosticTestFailed,
|
|
ups30AlarmCommunicationsLost, ups30AlarmShutdownPending,
|
|
and ups30AlarmTestInProgress."
|
|
|
|
OBJECT ups30TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. If no tests are supported, then the only
|
|
well known test type which must be supported is
|
|
ups30TestNoTestsInitiated."
|
|
|
|
OBJECT ups30OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups30BasicBypassGroup
|
|
DESCRIPTION
|
|
"The ups30BasicBypassGroup is only required for UPSs
|
|
that have a Bypass present."
|
|
OBJECT ups30ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups30Compliances 2 }
|
|
|
|
ups30FullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for UPSs that support
|
|
advanced full-featured functions."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { ups30FullIdentGroup, ups30FullBatteryGroup,
|
|
ups30FullInputGroup, ups30FullOutputGroup,
|
|
ups30FullAlarmGroup, ups30FullTestGroup,
|
|
ups30FullControlGroup }
|
|
|
|
OBJECT ups30AlarmDescr
|
|
DESCRIPTION
|
|
"Support of all `well known' alarm types is not
|
|
required. The well known alarm types which must be
|
|
supported are: ups30AlarmBatteryBad, ups30AlarmOnBattery,
|
|
ups30AlarmLowBattery, ups30AlarmDepletedBattery,
|
|
ups30AlarmTempBad, ups30AlarmInputBad, ups30AlarmOnBypass,
|
|
ups30AlarmBypassBad, ups30AlarmOutputOffAsRequested,
|
|
ups30AlarmUpsOffAsRequested, ups30AlarmUpsOutputOff,
|
|
ups30AlarmUpsSystemOff, ups30AlarmGeneralFault,
|
|
ups30AlarmDiagnosticTestFailed,
|
|
ups30AlarmCommunicationsLost, ups30AlarmShutdownPending,
|
|
and ups30AlarmTestInProgress."
|
|
|
|
OBJECT ups30TestId
|
|
DESCRIPTION
|
|
"Support of all `well known' test types is not
|
|
required. The well known test types which must be
|
|
supported are: ups30TestNoTestsInitiated,
|
|
ups30TestGeneralSystemsTest, and
|
|
ups30TestQuickBatteryTest."
|
|
|
|
OBJECT ups30OutputSource
|
|
SYNTAX INTEGER {
|
|
normal(2),
|
|
battery(4)
|
|
}
|
|
DESCRIPTION
|
|
"Support of the values other(1), none(2), bypass(4),
|
|
booster(6) and reducer(7) is not required."
|
|
|
|
GROUP ups30FullBypassGroup
|
|
DESCRIPTION
|
|
"The ups30FullBypassGroup is only required for UPSs that
|
|
have a Bypass present."
|
|
|
|
OBJECT ups30ShutdownType
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION
|
|
"Read-write access is not required, i.e., compliant
|
|
systems need not support more than one shutdown type."
|
|
|
|
::= { ups30Compliances 3 }
|
|
|
|
|
|
--
|
|
-- units of conformance
|
|
--
|
|
|
|
-- summary at a glance:
|
|
|
|
-- subset basic adv
|
|
--upsIdentManufacturer x x x
|
|
--upsIdentModel x x x
|
|
--upsIdentUPSSoftwareVersion x x
|
|
--upsIdentAgentSoftwareVersion x x x
|
|
--upsIdentName x x x
|
|
--upsIdentAttachedDevices x x
|
|
--
|
|
--upsBatteryStatus x x x notes
|
|
--upsSecondsOnBattery x x x
|
|
--upsEstimatedMinutesRemaining x
|
|
--upsEstimatedChargeRemaining x
|
|
--upsBatteryVoltage
|
|
--upsBatteryCurrent
|
|
--upsBatteryTemperature
|
|
--
|
|
--upsInputLineBads x x x
|
|
--upsInputNumLines x x
|
|
--upsInputFrequency x x
|
|
--upsInputVoltage x x
|
|
--upsInputCurrent
|
|
--
|
|
--upsOutputSource x x x notes
|
|
--upsOutputFrequency x x
|
|
--upsOutputNumLines x x
|
|
--upsOutputVoltage x x
|
|
--upsOutputCurrent x
|
|
--upsOutputPower x
|
|
--upsOutputPercentLoad x
|
|
--
|
|
--
|
|
--upsBypassFrequency x x notes
|
|
--upsBypassNumLines x x
|
|
--upsBypassVoltage x x
|
|
--upsBypassCurrent
|
|
--upsBypassPower
|
|
--
|
|
--
|
|
--upsAlarmsPresent x x x
|
|
--upsAlarmDescr x x x notes
|
|
--upsAlarmTime x x x
|
|
--
|
|
--upsTestId x x notes
|
|
--upsTestSpinLock x x
|
|
--upsTestResultsSummary x x
|
|
--upsTestResultsDetail x x
|
|
--upsTestStartTime x x
|
|
--upsTestElapsedTime x x
|
|
--
|
|
--upsShutdownType x x x notes
|
|
--upsShutdownAfterDelay x x x
|
|
--upsStartupAfterDelay x x
|
|
--upsRebootWithDuration x x
|
|
|
|
|
|
-- units of conformance
|
|
ups30Groups OBJECT IDENTIFIER ::= { ups30Conformance 2 }
|
|
|
|
ups30SubsetGroups OBJECT IDENTIFIER ::= { ups30Groups 1 }
|
|
|
|
ups30SubsetIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups30IdentManufacturer, ups30IdentModel,
|
|
ups30IdentAgentSoftwareVersion, ups30IdentName,
|
|
ups30IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetIdentGroup defines objects which are
|
|
common across all UPSs which meet subset compliance.
|
|
Most devices which conform to the ups30SubsetIdentGroup
|
|
will provide access to these objects via a proxy
|
|
agent. If the proxy agent is compatible with multiple
|
|
UPS types, configuration of the proxy agent will
|
|
require specifying some of these values, either
|
|
individually, or as a group (perhaps through a table
|
|
lookup mechanism based on the UPS model number)."
|
|
::= { ups30SubsetGroups 1 }
|
|
|
|
ups30SubsetBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups30BatteryStatus, ups30SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetBatteryGroup defines the objects that
|
|
are common to battery groups of two-contact UPSs."
|
|
::= { ups30SubsetGroups 2 }
|
|
|
|
ups30SubsetInputGroup OBJECT-GROUP
|
|
OBJECTS { ups30InputLineBads }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetInputGroup defines the objects that are
|
|
common to the Input groups of two-contact UPSs."
|
|
::= { ups30SubsetGroups 3 }
|
|
|
|
ups30SubsetOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups30OutputSource }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetOutputGroup defines the objects that are
|
|
common to the Output groups of two-contact UPSs."
|
|
::= { ups30SubsetGroups 4 }
|
|
|
|
|
|
-- { ups30SubsetGroups 5 } is reserved for
|
|
-- future use (upsSubsetBypassGroup)
|
|
|
|
ups30SubsetAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups30AlarmsPresent, ups30AlarmDescr, ups30AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetAlarmGroup defines the objects that are
|
|
common to the Alarm groups of two-contact UPSs."
|
|
::= { ups30SubsetGroups 6 }
|
|
|
|
-- { ups30SubsetGroups 7 } is reserved for
|
|
-- future use (upsSubsetTestGroup)
|
|
|
|
ups30SubsetControlGroup OBJECT-GROUP
|
|
OBJECTS { ups30ShutdownType, ups30ShutdownAfterDelay }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30SubsetControlGroup defines the objects that
|
|
are common to the Control groups of two-contact UPSs."
|
|
::= { ups30SubsetGroups 8 }
|
|
|
|
ups30BasicGroups OBJECT IDENTIFIER ::= { ups30Groups 2 }
|
|
|
|
ups30BasicIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups30IdentManufacturer, ups30IdentModel,
|
|
ups30IdentUPSSoftwareVersion,
|
|
ups30IdentAgentSoftwareVersion, ups30IdentName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicIdentGroup defines objects which are
|
|
common to the Ident group of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 1 }
|
|
|
|
ups30BasicBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups30BatteryStatus, ups30SecondsOnBattery }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicBatteryGroup defines the objects that are
|
|
common to the battery groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 2 }
|
|
|
|
ups30BasicInputGroup OBJECT-GROUP
|
|
OBJECTS { ups30InputLineBads, ups30InputNumLines,
|
|
ups30InputFrequency, ups30InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicInputGroup defines the objects that are
|
|
common to the Input groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 3 }
|
|
|
|
ups30BasicOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups30OutputSource, ups30OutputFrequency,
|
|
ups30OutputNumLines, ups30OutputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicOutputGroup defines the objects that are
|
|
common to the Output groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 4 }
|
|
|
|
ups30BasicBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups30BypassFrequency, ups30BypassNumLines,
|
|
ups30BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicBypassGroup defines the objects that are
|
|
common to the Bypass groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 5 }
|
|
|
|
ups30BasicAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups30AlarmsPresent, ups30AlarmDescr, ups30AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups30BasicAlarmGroup defines the objects that are
|
|
common to the Alarm groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 6 }
|
|
|
|
ups30BasicTestGroup OBJECT-GROUP
|
|
OBJECTS { ups30TestId, ups30TestSpinLock,
|
|
ups30TestResultsSummary, ups30TestResultsDetail,
|
|
ups30TestStartTime, ups30TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicTestGroup defines the objects that are
|
|
common to the Test groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 7 }
|
|
|
|
ups30BasicControlGroup OBJECT-GROUP
|
|
OBJECTS { ups30ShutdownType, ups30ShutdownAfterDelay,
|
|
ups30StartupAfterDelay, ups30RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30BasicControlGroup defines the objects that are
|
|
common to the Control groups of compliant UPSs which
|
|
support basic functions."
|
|
::= { ups30BasicGroups 8 }
|
|
|
|
ups30FullGroups OBJECT IDENTIFIER ::= { ups30Groups 3 }
|
|
|
|
ups30FullIdentGroup OBJECT-GROUP
|
|
OBJECTS { ups30IdentManufacturer, ups30IdentModel,
|
|
ups30IdentUPSSoftwareVersion,
|
|
ups30IdentAgentSoftwareVersion, ups30IdentName,
|
|
ups30IdentAttachedDevices }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullIdentGroup defines objects which are
|
|
common to the Ident group of fully compliant UPSs."
|
|
::= { ups30FullGroups 1 }
|
|
|
|
ups30FullBatteryGroup OBJECT-GROUP
|
|
OBJECTS { ups30BatteryStatus, ups30SecondsOnBattery,
|
|
ups30EstimatedMinutesRemaining,
|
|
ups30EstimatedChargeRemaining }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullBatteryGroup defines the objects that are
|
|
common to the battery groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 2 }
|
|
|
|
ups30FullInputGroup OBJECT-GROUP
|
|
OBJECTS { ups30InputLineBads, ups30InputNumLines,
|
|
ups30InputFrequency, ups30InputVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullInputGroup defines the objects that are
|
|
common to the Input groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 3 }
|
|
|
|
ups30FullOutputGroup OBJECT-GROUP
|
|
OBJECTS { ups30OutputSource, ups30OutputFrequency,
|
|
ups30OutputNumLines, ups30OutputVoltage,
|
|
ups30OutputCurrent, ups30OutputPower,
|
|
ups30OutputPercentLoad }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullOutputGroup defines the objects that are
|
|
common to the Output groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 4 }
|
|
|
|
ups30FullBypassGroup OBJECT-GROUP
|
|
OBJECTS { ups30BypassFrequency, ups30BypassNumLines,
|
|
ups30BypassVoltage }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullBypassGroup defines the objects that are
|
|
common to the Bypass groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 5 }
|
|
|
|
ups30FullAlarmGroup OBJECT-GROUP
|
|
OBJECTS { ups30AlarmsPresent, ups30AlarmDescr, ups30AlarmTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The ups30FullAlarmGroup defines the objects that are
|
|
common to the Alarm groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 6 }
|
|
|
|
ups30FullTestGroup OBJECT-GROUP
|
|
OBJECTS { ups30TestId, ups30TestSpinLock,
|
|
ups30TestResultsSummary, ups30TestResultsDetail,
|
|
ups30TestStartTime, ups30TestElapsedTime }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullTestGroup defines the objects that are
|
|
common to the Test groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 7 }
|
|
|
|
ups30FullControlGroup OBJECT-GROUP
|
|
OBJECTS { ups30ShutdownType, ups30ShutdownAfterDelay,
|
|
ups30StartupAfterDelay, ups30RebootWithDuration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ups30FullControlGroup defines the objects that are
|
|
common to the Control groups of fully compliant UPSs."
|
|
::= { ups30FullGroups 8 }
|
|
|
|
END
|