- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
10023 lines
350 KiB
Text
10023 lines
350 KiB
Text
APRISAXE-MIB-4RF DEFINITIONS ::= BEGIN
|
|
|
|
--
|
|
-- File: $Id: 4RF-APRISAXE-MIB.txt,v 1.148.2.1 2007/09/17 01:31:14 di Exp $
|
|
--
|
|
-- Copyright: 2004 4RF COMMUNICATIONS LTD
|
|
--
|
|
-- Description:
|
|
-- MIB for AprisaXE project.
|
|
--
|
|
-- Versions:
|
|
--
|
|
-- Release 3
|
|
-- Added support for 4-wire cards and configurable cross-connections
|
|
--
|
|
-- Notes:
|
|
-- None
|
|
--
|
|
|
|
|
|
IMPORTS
|
|
|
|
-- Standard imports
|
|
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, NOTIFICATION-TYPE,
|
|
Integer32, Unsigned32, Counter32, IpAddress
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
-- 4RF Specific imports
|
|
fourRFAprisaXE
|
|
FROM PRODUCTS-MIB-4RF
|
|
FourRFAlarmStatus, FourRFAlarmSeverity, FourRFAlarmEnabled, FourRFAlarmPresent,
|
|
FourRFImageVersion, FourRFHardwareVersion, FourRFSerialNumber, FourRFChannelWidth,
|
|
FourRFRSSI, FourRFModulationType, FourRFErrorCounter, FourRFFanStatus,
|
|
FourRFTemperature, FourRFFrequency, FourRFTxPower, FourRFRfBand, FourRFSNR,
|
|
FourRFClockSource, FourRFNetworkClockSelect, FourRFLoopback,
|
|
FourRFNetworkClockStatus, FourRFMHSBStatus, FourRFMHSBCommand, FourRFProcessResultType
|
|
FROM COMMON-TC-4RF
|
|
AprisaXESlotNumber, AprisaXECardType, AprisaXEAlarmSource, AprisaXEPortNumber,
|
|
AprisaXEAlarmMapping, AprisaXEAdcVoltage,AprisaXEDbValue, AprisaXEIQData,
|
|
AprisaXEAlarmType, AprisaXEChannelControlType, AprisaXETdmPortType,
|
|
AprisaXEHardwareVersion, AprisaXEDataStatus,
|
|
AprisaXEQuadJetTrafficType, AprisaXEAlarmPolarity, AprisaXEAlarmOutput,
|
|
AprisaXEQuadJetLineEncoding, AprisaXE4WRxGain, AprisaXE4WTxGain,
|
|
AprisaXE4WInputLevel, AprisaXE4WOutputLevel,
|
|
AprisaXEFXOInputLevel, AprisaXEFXOOutputLevel,
|
|
AprisaXEFXSInputLevel, AprisaXEFXSOutputLevel, AprisaXEFXSPathMute,
|
|
AprisaXESignalState, AprisaXETdmBus,AprisaXEPcmLaw,AprisaXEFXOCountry,
|
|
AprisaXEAdpcmCompression,AprisaXEFXSPMLevel,
|
|
AprisaXEInterfaceCnxnType,AprisaXEConnectionID,
|
|
AprisaXEPcmMode,AprisaXESerialEquipmentMode,
|
|
AprisaXEQuadJetConnectionType, AprisaXEHssSerialMode, AprisaXE2WireSignalState,
|
|
AprisaXEEthernetPortNumber, AprisaXEEthernetGroup,
|
|
AprisaXEEthernetFrameRate, AprisaXEEthernetPortPriority,
|
|
AprisaXEEthernetGrouping, AprisaXEEthernetPrioQueueScheduling, AprisaXEEthernetPrioQueueMapping,
|
|
AprisaXEDefaultAction, AprisaXEQuadJetLoopbacks, AprisaXEQuadJetWaveFormShapers,
|
|
AprisaXECCActivationStatus, AprisaXEQuadJetMultiframeEnable,
|
|
AprisaXEPSCActiveRadio, AprisaXEPSCActiveTx
|
|
FROM APRISAXE-TC-4RF
|
|
fourRFModules
|
|
FROM MIB-4RF;
|
|
|
|
|
|
-- Module Identification
|
|
fourRFAprisaXEModule MODULE-IDENTITY
|
|
LAST-UPDATED "200704300000Z"
|
|
ORGANIZATION "www.4rf.com"
|
|
CONTACT-INFO
|
|
"postal: 4RF Communications Ltd
|
|
26 Glover Street
|
|
Ngauranga
|
|
PO Box 13-506
|
|
Wellington 6032
|
|
New Zealand
|
|
|
|
phone: +64 4 499 6000
|
|
email: support@4rf.com"
|
|
DESCRIPTION "MIB for the AprisaXE project"
|
|
|
|
-- Revision history
|
|
-- (in reverse chronological order)
|
|
|
|
REVISION "200704300000Z"
|
|
DESCRIPTION "Second draft"
|
|
|
|
REVISION "200412090304Z"
|
|
DESCRIPTION "First draft"
|
|
::= { fourRFModules 5 }
|
|
|
|
|
|
aprisaXEConfig OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The root of the OID sub-tree for the AprisaXE product configuration."
|
|
::= { fourRFAprisaXE 1 }
|
|
|
|
aprisaXEGroups OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The root of the OID sub-tree for the AprisaXE object groups."
|
|
::= { aprisaXEConfig 1 }
|
|
|
|
aprisaXEObjects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The root of the OID sub-tree for the AprisaXE product objects."
|
|
::= { aprisaXEConfig 2 }
|
|
|
|
aprisaXEEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The root of the OID sub-tree for the AprisaXE product events."
|
|
::= { aprisaXEConfig 3 }
|
|
|
|
aprisaXEEventsV2 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE product events, ensures SNMPv1 compatibility."
|
|
::= { aprisaXEEvents 0 }
|
|
|
|
aprisaXETestObjects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "The root of the OID sub-tree for the AprisaXE test objects."
|
|
::= { aprisaXEConfig 4 }
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Terminal Settings
|
|
--
|
|
-- This object group provides access to basic terminal information such as the
|
|
-- Rx and Tx frequencies. This is a product specific enhancement to the common
|
|
-- terminalGroup defined in the COMMON-4RF MIB.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXETerminal OBJECT IDENTIFIER ::= { aprisaXEObjects 1 }
|
|
|
|
aprisaXETerminalRfChannelWidth OBJECT-TYPE
|
|
SYNTAX FourRFChannelWidth
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal RF channel width, the options are:
|
|
20kHz, 25kHz, 50kHz, 75kHz, 100kHz, 125kHz, 150kHz, 200kHz, 250kHz,
|
|
400kHz, 500kHz, 800kHz,
|
|
1MHz, 1.25MHz,
|
|
1.75MHz, 2MHz,
|
|
3.5MHz, 7MHz"
|
|
::= { aprisaXETerminal 4 }
|
|
|
|
aprisaXETerminalRSSI OBJECT-TYPE
|
|
SYNTAX FourRFRSSI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal RSSI in dBm."
|
|
::= { aprisaXETerminal 5 }
|
|
|
|
aprisaXETerminalModulationState OBJECT-TYPE
|
|
SYNTAX FourRFModulationType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal modulation state."
|
|
::= { aprisaXETerminal 6 }
|
|
|
|
aprisaXETerminalClockReference OBJECT-TYPE
|
|
SYNTAX INTEGER { automatic (0),
|
|
manual (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal clock reference configuration:
|
|
automatic -
|
|
manual - "
|
|
::= { aprisaXETerminal 7 }
|
|
|
|
aprisaXETerminalClockSource OBJECT-TYPE
|
|
SYNTAX FourRFClockSource
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal clock source configuration:
|
|
network - clocking is recovered from the synchronous network
|
|
to which the terminal is connected.
|
|
link - clocking is recovered from the remote end of the link.
|
|
internal - the clock is generated internally.
|
|
The clock reference must be in manual mode for this to take effect."
|
|
::= { aprisaXETerminal 8 }
|
|
|
|
aprisaXETerminalAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal alarm status, this reflects the overall status of the
|
|
terminal. This will match the colour of the front panel control LED.
|
|
The states used are noAlarm, minorAlarm and majorAlarm."
|
|
::= { aprisaXETerminal 9 }
|
|
|
|
aprisaXETerminalRxAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal alarm status, this reflects the overall RX status of the
|
|
terminal. This will match the colour of the front panel RX LED.
|
|
The states used are noAlarm, minorAlarm and majorAlarm."
|
|
::= { aprisaXETerminal 10 }
|
|
|
|
aprisaXETerminalTxAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal alarm status, this reflects the overall TX status of the
|
|
terminal. This will match the colour of the front panel TX LED.
|
|
The states used are noAlarm, minorAlarm and majorAlarm."
|
|
::= { aprisaXETerminal 11 }
|
|
|
|
aprisaXETerminalBandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This returns the total bandwidth available over the link in kbps."
|
|
::= { aprisaXETerminal 12 }
|
|
|
|
aprisaXEMotherboardSerialNumber OBJECT-TYPE
|
|
SYNTAX FourRFSerialNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The unique serial number for the motherboard."
|
|
::= { aprisaXETerminal 13 }
|
|
|
|
aprisaXETerminalAllocatedBandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This returns the total bandwidth allocated over the link in kbps."
|
|
::= { aprisaXETerminal 14 }
|
|
|
|
aprisaXETerminalLoopbackBandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This returns the total loopback bandwidth allocated in kbps."
|
|
::= { aprisaXETerminal 15 }
|
|
|
|
aprisaXETerminalNetworkClockPrimaryStatus OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This returns the status of the network clock primary source."
|
|
::= { aprisaXETerminal 16 }
|
|
|
|
aprisaXETerminalNetworkClockSecondaryStatus OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This returns the status of the network clock secondary source."
|
|
::= { aprisaXETerminal 17 }
|
|
|
|
aprisaXETerminalNetworkClockCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { none (0),
|
|
makePrimaryActive (1),
|
|
makeSecondaryActive (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Forces a change in the active network clock."
|
|
::= { aprisaXETerminal 18}
|
|
|
|
aprisaXETerminalStartupComplete OBJECT-TYPE
|
|
SYNTAX INTEGER { notComplete (0),
|
|
startupComplete (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the terminal startup sequence is complete."
|
|
::= { aprisaXETerminal 19 }
|
|
|
|
aprisaXETerminalImageAlarmClear OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
clearAlternateImageAlarm (1),
|
|
clearDefaultImageAlarm (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the terminal startup sequence is complete."
|
|
::= { aprisaXETerminal 20 }
|
|
|
|
aprisaXETerminalMuxStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { none (0),
|
|
muxOnly (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "This indicates if the terminal is operating in Mux mode."
|
|
::= { aprisaXETerminal 21 }
|
|
|
|
aprisaXETerminalBootloaderDataVersion OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates the data version of the shared data field in the bootloader."
|
|
::= { aprisaXETerminal 22 }
|
|
|
|
aprisaXETerminalUploadFailAlarmClear OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
clearUploadFailAlarm (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Used to clear a current Upload Failure Alarm."
|
|
::= { aprisaXETerminal 23 }
|
|
|
|
aprisaXETerminalEquipmentType OBJECT-TYPE
|
|
SYNTAX INTEGER { axeUnknown (0),
|
|
axeRadio (1),
|
|
axeMux (2),
|
|
axeProtSwitch (3),
|
|
axeProtRadio (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This indicates what type of equipment the terminal is."
|
|
::= { aprisaXETerminal 24 }
|
|
|
|
|
|
aprisaXETerminalGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETerminalRfChannelWidth,
|
|
aprisaXETerminalRSSI,
|
|
aprisaXETerminalModulationState,
|
|
aprisaXETerminalClockReference,
|
|
aprisaXETerminalClockSource,
|
|
aprisaXETerminalAlarmStatus,
|
|
aprisaXETerminalRxAlarmStatus,
|
|
aprisaXETerminalTxAlarmStatus,
|
|
aprisaXETerminalBandwidth,
|
|
aprisaXEMotherboardSerialNumber,
|
|
aprisaXETerminalAllocatedBandwidth,
|
|
aprisaXETerminalLoopbackBandwidth,
|
|
aprisaXETerminalNetworkClockPrimaryStatus,
|
|
aprisaXETerminalNetworkClockSecondaryStatus,
|
|
aprisaXETerminalNetworkClockCommand,
|
|
aprisaXETerminalStartupComplete,
|
|
aprisaXETerminalImageAlarmClear,
|
|
aprisaXETerminalMuxStatus,
|
|
aprisaXETerminalBootloaderDataVersion,
|
|
aprisaXETerminalUploadFailAlarmClear,
|
|
aprisaXETerminalEquipmentType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE terminal settings group."
|
|
::= { aprisaXEGroups 1 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Terminal Settings
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Terminal performance information
|
|
--
|
|
-- This section provides basic performance statistics for the terminal.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEPerformance OBJECT IDENTIFIER ::= { aprisaXEObjects 6 }
|
|
|
|
aprisaXECorrectableErrorCount OBJECT-TYPE
|
|
SYNTAX FourRFErrorCounter
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal correctable error count."
|
|
::= { aprisaXEPerformance 1 }
|
|
|
|
aprisaXEUncorrectableErrorCount OBJECT-TYPE
|
|
SYNTAX FourRFErrorCounter
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal uncorrectable error count."
|
|
::= { aprisaXEPerformance 2 }
|
|
|
|
aprisaXEModemSNR OBJECT-TYPE
|
|
SYNTAX FourRFSNR
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The modem signal to noise ratio."
|
|
::= { aprisaXEPerformance 3 }
|
|
|
|
aprisaXETxPacketCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal transmitted ethernet packet count (to link)."
|
|
::= { aprisaXEPerformance 4 }
|
|
|
|
aprisaXERxPacketCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal received ethernet packet count (from link)."
|
|
::= { aprisaXEPerformance 5 }
|
|
|
|
aprisaXERxPacketErrorCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal received ethernet packet error count (from link)."
|
|
::= { aprisaXEPerformance 6 }
|
|
|
|
aprisaXEErrorCounterCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { countersRunning (0),
|
|
resetCounters (1),
|
|
freezeCounters (2),
|
|
unfreezeCounters (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Forces reset, freeze or unfreeze the error counters."
|
|
::= { aprisaXEPerformance 7 }
|
|
|
|
aprisaXEErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Error Free Seconds for the terminal."
|
|
::= { aprisaXEPerformance 8 }
|
|
|
|
aprisaXEErroredSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Errored Seconds for the terminal."
|
|
::= { aprisaXEPerformance 9 }
|
|
|
|
aprisaXEBERExponent OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..64) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The exponent of the Bit Error Rate for the terminal."
|
|
::= { aprisaXEPerformance 10 }
|
|
|
|
aprisaXEPscSysUncorrectableErrorCount OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..64) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal uncorrectable error count."
|
|
::= { aprisaXEPerformance 11 }
|
|
|
|
aprisaXEPscSysErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Error Free Seconds for the terminal."
|
|
::= { aprisaXEPerformance 12 }
|
|
|
|
aprisaXEPscSysErroredSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Errored Seconds for the terminal."
|
|
::= { aprisaXEPerformance 13 }
|
|
|
|
aprisaXEPscSysBERExponent OBJECT-TYPE
|
|
SYNTAX DisplayString( SIZE(0..64) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The exponent of the Bit Error Rate for the terminal."
|
|
::= { aprisaXEPerformance 14 }
|
|
|
|
aprisaXEPscRadioAUncorrectableErrorCount OBJECT-TYPE
|
|
SYNTAX FourRFErrorCounter
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal uncorrectable error count."
|
|
::= { aprisaXEPerformance 15 }
|
|
|
|
aprisaXEPscRadioAErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Error Free Seconds for the terminal."
|
|
::= { aprisaXEPerformance 16 }
|
|
|
|
aprisaXEPscRadioAErroredSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Errored Seconds for the terminal."
|
|
::= { aprisaXEPerformance 17 }
|
|
|
|
aprisaXEPscRadioABERExponent OBJECT-TYPE
|
|
SYNTAX DisplayString( SIZE(0..64) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The exponent of the Bit Error Rate for the terminal."
|
|
::= { aprisaXEPerformance 18 }
|
|
|
|
aprisaXEPscRadioBUncorrectableErrorCount OBJECT-TYPE
|
|
SYNTAX FourRFErrorCounter
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The terminal uncorrectable error count."
|
|
::= { aprisaXEPerformance 19 }
|
|
|
|
aprisaXEPscRadioBErrorFreeSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Error Free Seconds for the terminal."
|
|
::= { aprisaXEPerformance 20 }
|
|
|
|
aprisaXEPscRadioBErroredSeconds OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Errored Seconds for the terminal."
|
|
::= { aprisaXEPerformance 21 }
|
|
|
|
aprisaXEPscRadioBBERExponent OBJECT-TYPE
|
|
SYNTAX DisplayString( SIZE(0..64) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The exponent of the Bit Error Rate for the terminal."
|
|
::= { aprisaXEPerformance 22 }
|
|
|
|
aprisaXEPerformanceGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXECorrectableErrorCount,
|
|
aprisaXEUncorrectableErrorCount,
|
|
aprisaXEModemSNR,
|
|
aprisaXETxPacketCount,
|
|
aprisaXERxPacketCount,
|
|
aprisaXERxPacketErrorCount,
|
|
aprisaXEErrorCounterCommand,
|
|
aprisaXEErrorFreeSeconds,
|
|
aprisaXEErroredSeconds,
|
|
aprisaXEBERExponent,
|
|
aprisaXEPscSysUncorrectableErrorCount,
|
|
aprisaXEPscSysErrorFreeSeconds,
|
|
aprisaXEPscSysErroredSeconds,
|
|
aprisaXEPscSysBERExponent,
|
|
aprisaXEPscRadioAUncorrectableErrorCount,
|
|
aprisaXEPscRadioAErrorFreeSeconds,
|
|
aprisaXEPscRadioAErroredSeconds,
|
|
aprisaXEPscRadioABERExponent,
|
|
aprisaXEPscRadioBUncorrectableErrorCount,
|
|
aprisaXEPscRadioBErrorFreeSeconds,
|
|
aprisaXEPscRadioBErroredSeconds,
|
|
aprisaXEPscRadioBBERExponent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE terminal performance group."
|
|
::= { aprisaXEGroups 6 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Performance
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- External Alarms
|
|
--
|
|
-- This section specifies the MIB attributes for handling external alarm
|
|
-- inputs and outputs. For AprisaXE there are two external alarm inputs
|
|
-- and four external alarm outputs. Two of the external alarm outputs will
|
|
-- be used to reflect the alarm state of the remote terminal, one for major
|
|
-- and one for minor alarms.
|
|
--
|
|
-- The alarms can be enabled and disabled and the severity associated with
|
|
-- the inputs can be set. The polarity indicating an alarm can also be set.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEExternalAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 11 }
|
|
|
|
-- The first external alarm input
|
|
aprisaXEExternalAlarm1 OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 1 }
|
|
|
|
aprisaXEExternalAlarm1Status OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the first external alarm input."
|
|
::= { aprisaXEExternalAlarm1 1 }
|
|
|
|
aprisaXEExternalAlarm1Severity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The severity of the first external alarm input."
|
|
::= { aprisaXEExternalAlarm1 2 }
|
|
|
|
aprisaXEExternalAlarm1Enabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the first external alarm input is enabled.
|
|
If not changes to the input will be ignored. By default the
|
|
alarm is enabled."
|
|
::= { aprisaXEExternalAlarm1 3 }
|
|
|
|
aprisaXEExternalAlarm1Mapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the first external alarm input is mapped to
|
|
the remote alarms."
|
|
::= { aprisaXEExternalAlarm1 4 }
|
|
|
|
aprisaXEExternalAlarm1Description OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..64) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A description (user defined) for the external alarm."
|
|
::= { aprisaXEExternalAlarm1 5 }
|
|
|
|
aprisaXEExternalAlarm1Group OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarm1Status,
|
|
aprisaXEExternalAlarm1Severity,
|
|
aprisaXEExternalAlarm1Enabled,
|
|
aprisaXEExternalAlarm1Mapping,
|
|
aprisaXEExternalAlarm1Description
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE first external alarm input group."
|
|
::= { aprisaXEGroups 11 }
|
|
|
|
|
|
-- The second external alarm input
|
|
aprisaXEExternalAlarm2 OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 2 }
|
|
|
|
aprisaXEExternalAlarm2Status OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the second external alarm input."
|
|
::= { aprisaXEExternalAlarm2 1 }
|
|
|
|
aprisaXEExternalAlarm2Severity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The severity of the second external alarm input."
|
|
::= { aprisaXEExternalAlarm2 2 }
|
|
|
|
aprisaXEExternalAlarm2Enabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the second external alarm input is enabled.
|
|
If not changes to the input will be ignored. By default the
|
|
alarm is enabled."
|
|
::= { aprisaXEExternalAlarm2 3 }
|
|
|
|
aprisaXEExternalAlarm2Mapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the second external alarm input is mapped to
|
|
the remote alarms."
|
|
::= { aprisaXEExternalAlarm2 4 }
|
|
|
|
aprisaXEExternalAlarm2Description OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..64) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A description (user defined) for the external alarm."
|
|
::= { aprisaXEExternalAlarm2 5 }
|
|
|
|
aprisaXEExternalAlarm2Group OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarm2Status,
|
|
aprisaXEExternalAlarm2Severity,
|
|
aprisaXEExternalAlarm2Enabled,
|
|
aprisaXEExternalAlarm2Mapping,
|
|
aprisaXEExternalAlarm2Description
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE second external alarm input group."
|
|
::= { aprisaXEGroups 16 }
|
|
|
|
|
|
-- General configuration
|
|
|
|
aprisaXEExternalAlarmPolarity OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmPolarity
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the polarity used to indicate the presence of an
|
|
alarm at an external alarm input."
|
|
::= { aprisaXEExternalAlarms 3 }
|
|
|
|
aprisaXEExternalAlarmOutputPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER { polarityClosed (0),
|
|
polarityOpen (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the polarity used to indicate the presence of an
|
|
alarm at an external alarm output, this may be different from
|
|
the input polarity."
|
|
::= { aprisaXEExternalAlarms 4 }
|
|
|
|
aprisaXEExternalAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarmPolarity,
|
|
aprisaXEExternalAlarmOutputPolarity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE general external alarm details group."
|
|
::= { aprisaXEGroups 17 }
|
|
|
|
|
|
-- The first external alarm output
|
|
aprisaXEExternalAlarmOutputOne OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 5 }
|
|
|
|
aprisaXEExternalAlarmOutputOneStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the first external alarm output."
|
|
::= { aprisaXEExternalAlarmOutputOne 1 }
|
|
|
|
aprisaXEExternalAlarmOutputOneMapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the first external alarm output is mapped to
|
|
the alarms."
|
|
::= { aprisaXEExternalAlarmOutputOne 2 }
|
|
|
|
aprisaXEExternalAlarmOutputOneGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarmOutputOneStatus,
|
|
aprisaXEExternalAlarmOutputOneMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE first external alarm output group."
|
|
::= { aprisaXEGroups 12 }
|
|
|
|
-- The second external alarm output
|
|
aprisaXEExternalAlarmOutputTwo OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 6 }
|
|
|
|
aprisaXEExternalAlarmOutputTwoStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the second external alarm output."
|
|
::= { aprisaXEExternalAlarmOutputTwo 1 }
|
|
|
|
aprisaXEExternalAlarmOutputTwoMapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the second external alarm output is mapped to
|
|
the alarms."
|
|
::= { aprisaXEExternalAlarmOutputTwo 2 }
|
|
|
|
aprisaXEExternalAlarmOutputTwoGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarmOutputTwoStatus,
|
|
aprisaXEExternalAlarmOutputTwoMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE second external alarm output group."
|
|
::= { aprisaXEGroups 13 }
|
|
|
|
-- The third external alarm output
|
|
aprisaXEExternalAlarmOutputThree OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 7 }
|
|
|
|
aprisaXEExternalAlarmOutputThreeStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the third external alarm output."
|
|
::= { aprisaXEExternalAlarmOutputThree 1 }
|
|
|
|
aprisaXEExternalAlarmOutputThreeMapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the third external alarm output is mapped to
|
|
the alarms."
|
|
::= { aprisaXEExternalAlarmOutputThree 2 }
|
|
|
|
aprisaXEExternalAlarmOutputThreeGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarmOutputThreeStatus,
|
|
aprisaXEExternalAlarmOutputThreeMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE third external alarm output group."
|
|
::= { aprisaXEGroups 14 }
|
|
|
|
-- The fourth external alarm output
|
|
aprisaXEExternalAlarmOutputFour OBJECT IDENTIFIER ::= { aprisaXEExternalAlarms 8 }
|
|
|
|
aprisaXEExternalAlarmOutputFourStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the fourth external alarm output."
|
|
::= { aprisaXEExternalAlarmOutputFour 1 }
|
|
|
|
aprisaXEExternalAlarmOutputFourMapping OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This defines how the fourth external alarm output is mapped to
|
|
the alarms."
|
|
::= { aprisaXEExternalAlarmOutputFour 2 }
|
|
|
|
aprisaXEExternalAlarmOutputFourGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEExternalAlarmOutputFourStatus,
|
|
aprisaXEExternalAlarmOutputFourMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE fourth external alarm output group."
|
|
::= { aprisaXEGroups 15 }
|
|
|
|
-- ***************************************************************************
|
|
-- End External Alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Remote Alarms
|
|
--
|
|
-- This section specifies the MIB attributes for handling alarms from the
|
|
-- remote terminal. The remote terminal can report a major or minor alarm
|
|
-- or both. The MIB will provide access to the status of both the major and
|
|
-- minor alarms. The remote alarms can be mapped to the external alarm outputs.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXERemoteAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 16 }
|
|
|
|
aprisaXEMajorRemoteAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the remote major alarm."
|
|
::= { aprisaXERemoteAlarms 1 }
|
|
|
|
aprisaXEMajorRemoteAlarmOutput OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmOutput
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "This defines how the remote major alarm is mapped to the
|
|
external alarm outputs."
|
|
::= { aprisaXERemoteAlarms 2 }
|
|
|
|
aprisaXEMinorRemoteAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the remote minor alarm."
|
|
::= { aprisaXERemoteAlarms 10 }
|
|
|
|
aprisaXEMinorRemoteAlarmOutput OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmOutput
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "This defines how the remote minor alarm is mapped to the
|
|
external alarm outputs."
|
|
::= { aprisaXERemoteAlarms 11 }
|
|
|
|
aprisaXERemoteAlarmGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEMajorRemoteAlarmStatus,
|
|
aprisaXEMajorRemoteAlarmOutput,
|
|
aprisaXEMinorRemoteAlarmStatus,
|
|
aprisaXEMinorRemoteAlarmOutput
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE remote alarm status group.
|
|
This group has been replaced by the now mappable external
|
|
alarm output OIDs aprisaXEExternalAlarmOutputXXXGroup."
|
|
::= { aprisaXEGroups 21 }
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- MHSB Mode
|
|
--
|
|
-- This section specifies the MIB attributes for handling MHSB Mode
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEMHSB OBJECT IDENTIFIER ::= {aprisaXEObjects 19 }
|
|
|
|
aprisaXEMHSBStatus OBJECT-TYPE
|
|
SYNTAX FourRFMHSBStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The state of an MHSB configured terminal."
|
|
::= {aprisaXEMHSB 1}
|
|
|
|
aprisaXEMHSBEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled (0),
|
|
enabled (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the terminal into Monitored Hot Standby Mode."
|
|
::= { aprisaXEMHSB 2}
|
|
|
|
aprisaXEMHSBCommand OBJECT-TYPE
|
|
SYNTAX FourRFMHSBCommand
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Commands to apply while in MHSB mode."
|
|
::= { aprisaXEMHSB 3}
|
|
|
|
aprisaXEMHSBTerminalSelect OBJECT-TYPE
|
|
SYNTAX INTEGER { none (0),
|
|
terminalA (1),
|
|
terminalB (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Configure terminal as terminal A or terminal B of an MHSB pair."
|
|
::= {aprisaXEMHSB 4}
|
|
|
|
aprisaXEMHSBSwitchoverStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the alarm reflecting if a switchover has occurred."
|
|
::= {aprisaXEMHSB 5}
|
|
|
|
aprisaXEMHSBGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEMHSBStatus,
|
|
aprisaXEMHSBEnable,
|
|
aprisaXEMHSBCommand,
|
|
aprisaXEMHSBTerminalSelect,
|
|
aprisaXEMHSBSwitchoverStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXE MHSB group."
|
|
::= { aprisaXEGroups 23}
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Fan Status
|
|
--
|
|
-- This section specifies the MIB attributes for handling the fan status.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEFans OBJECT IDENTIFIER ::= { aprisaXEObjects 21 }
|
|
|
|
aprisaXEFan1Status OBJECT-TYPE
|
|
SYNTAX FourRFFanStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the fan one."
|
|
::= { aprisaXEFans 1 }
|
|
|
|
aprisaXEFan2Status OBJECT-TYPE
|
|
SYNTAX FourRFFanStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the fan two."
|
|
::= { aprisaXEFans 2 }
|
|
|
|
aprisaXEFanEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { fansDisabled (0),
|
|
fansEnabled (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Turn the fans on or off."
|
|
::= { aprisaXEFans 3 }
|
|
|
|
aprisaXEFanGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEFan1Status,
|
|
aprisaXEFan2Status,
|
|
aprisaXEFanEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE fan status group."
|
|
::= { aprisaXEGroups 26 }
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- AlarmTable
|
|
--
|
|
-- This section defines the alarm table. This is used to report all currently
|
|
-- active alarms. A maximum of 500 alarms will be stored in the table.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table stores the currently active alarms. Up to 500
|
|
separate alarms will be stored in the table."
|
|
::= { aprisaXEObjects 26 }
|
|
|
|
AprisaXEAlarmEntry ::= SEQUENCE {
|
|
aprisaXEAlarmIndex INTEGER,
|
|
aprisaXEAlarmSlot INTEGER,
|
|
aprisaXEAlarmSource INTEGER,
|
|
aprisaXEAlarmPort INTEGER,
|
|
aprisaXEAlarmSeverity INTEGER,
|
|
aprisaXEAlarmType INTEGER,
|
|
aprisaXEAlarmTime OCTET STRING
|
|
}
|
|
|
|
aprisaXEAlarmEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table entry index specification, just the alarm index."
|
|
INDEX { aprisaXEAlarmIndex }
|
|
::= { aprisaXEAlarmTable 1 }
|
|
|
|
aprisaXEAlarmIndex OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..500 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The index into the alarm table."
|
|
::= { aprisaXEAlarmEntry 1 }
|
|
|
|
aprisaXEAlarmSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot generating the alarm."
|
|
::= { aprisaXEAlarmEntry 2 }
|
|
|
|
aprisaXEAlarmSource OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The source of the alarm, a card type or external."
|
|
::= { aprisaXEAlarmEntry 3 }
|
|
|
|
aprisaXEAlarmPort OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The source port of the alarm."
|
|
::= { aprisaXEAlarmEntry 4 }
|
|
|
|
aprisaXEAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the alarm."
|
|
::= { aprisaXEAlarmEntry 5 }
|
|
|
|
aprisaXEAlarmType OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of the alarm."
|
|
::= { aprisaXEAlarmEntry 6 }
|
|
|
|
aprisaXEAlarmTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The time that the alarm occurred."
|
|
::= { aprisaXEAlarmEntry 7 }
|
|
|
|
-- ***************************************************************************
|
|
-- End AlarmTable
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- AlarmHistoryTable
|
|
--
|
|
-- This section defines the alarm table. A maximum of 100 alarms will be stored
|
|
-- in the table.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEAlarmHistoryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEAlarmHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table stores a history of the alarms as they become
|
|
active and cleared."
|
|
::= { aprisaXEObjects 31 }
|
|
|
|
AprisaXEAlarmHistoryEntry ::= SEQUENCE {
|
|
aprisaXEAlarmHistoryIndex INTEGER,
|
|
aprisaXEAlarmHistorySlot INTEGER,
|
|
aprisaXEAlarmHistorySource INTEGER,
|
|
aprisaXEAlarmHistoryPort INTEGER,
|
|
aprisaXEAlarmHistorySeverity INTEGER,
|
|
aprisaXEAlarmHistoryType INTEGER,
|
|
aprisaXEAlarmHistoryPresent INTEGER,
|
|
aprisaXEAlarmHistoryTime OCTET STRING
|
|
}
|
|
|
|
aprisaXEAlarmHistoryEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmHistoryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The table entry index specification, just the alarm index."
|
|
INDEX { aprisaXEAlarmHistoryIndex }
|
|
::= { aprisaXEAlarmHistoryTable 1 }
|
|
|
|
aprisaXEAlarmHistoryIndex OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..100 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The index into the alarm history table."
|
|
::= { aprisaXEAlarmHistoryEntry 1 }
|
|
|
|
aprisaXEAlarmHistorySlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of the slot generating the alarm."
|
|
::= { aprisaXEAlarmHistoryEntry 2 }
|
|
|
|
aprisaXEAlarmHistorySource OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmSource
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The source of the alarm, a card type or external."
|
|
::= { aprisaXEAlarmHistoryEntry 3 }
|
|
|
|
aprisaXEAlarmHistoryPort OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The source port of the alarm."
|
|
::= { aprisaXEAlarmHistoryEntry 4 }
|
|
|
|
aprisaXEAlarmHistorySeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the alarm."
|
|
::= { aprisaXEAlarmHistoryEntry 5 }
|
|
|
|
|
|
aprisaXEAlarmHistoryType OBJECT-TYPE
|
|
SYNTAX AprisaXEAlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of the alarm."
|
|
::= { aprisaXEAlarmHistoryEntry 6 }
|
|
|
|
aprisaXEAlarmHistoryPresent OBJECT-TYPE
|
|
SYNTAX FourRFAlarmPresent
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the alarm is present or not."
|
|
::= { aprisaXEAlarmHistoryEntry 7 }
|
|
|
|
aprisaXEAlarmHistoryTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The time that the alarm state change occurred."
|
|
::= { aprisaXEAlarmHistoryEntry 8 }
|
|
|
|
-- ***************************************************************************
|
|
-- End AlarmHistoryTable
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
aprisaXEAlarmControl OBJECT IDENTIFIER ::= { aprisaXEObjects 32 }
|
|
|
|
aprisaXEAlarmHistoryCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
clearHistory (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Allows the alarm history table to be cleared."
|
|
::= { aprisaXEAlarmControl 1 }
|
|
|
|
aprisaXEAlarmControlGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEAlarmHistoryCommand }
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE alarm control group."
|
|
::= { aprisaXEGroups 32 }
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Transmitter - there is only one transmitter for each AprisaXE
|
|
--
|
|
-- NB: The units for all fields need to be confirmed
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXETransmitter OBJECT IDENTIFIER ::= { aprisaXEObjects 36 }
|
|
|
|
aprisaXETransmitterStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { transmitterOff (0),
|
|
transmitterOn (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter is currently on or off."
|
|
::= { aprisaXETransmitter 1 }
|
|
|
|
aprisaXETransmitterCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
transmitterOff (1),
|
|
transmitterOn (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Commands used to control the transmitter, currently the transmitter can
|
|
be switched on and off. No other commands are defined."
|
|
::= { aprisaXETransmitter 2 }
|
|
|
|
aprisaXETransmitterSynthesiserStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter synthesiser."
|
|
::= { aprisaXETransmitter 3 }
|
|
|
|
aprisaXETransmitter5VPowerStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter 5V power supply."
|
|
::= { aprisaXETransmitter 4 }
|
|
|
|
aprisaXETransmitter11VPowerStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter 11V power supply."
|
|
::= { aprisaXETransmitter 5 }
|
|
|
|
aprisaXETransmitter28VPowerStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter 28V power supply."
|
|
::= { aprisaXETransmitter 6 }
|
|
|
|
aprisaXETransmitterFrequency OBJECT-TYPE
|
|
SYNTAX FourRFFrequency
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal transmit frequency in MHz. The possible bands are:
|
|
330 to 400 MHz (300 MHz)
|
|
400 to 470 MHz (400 MHz)
|
|
1350 to 1550 MHz (1400 MHz)
|
|
The frequency value should be supplied in Hz."
|
|
::= { aprisaXETransmitter 7 }
|
|
|
|
aprisaXETransmitterPower OBJECT-TYPE
|
|
SYNTAX FourRFTxPower
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The TX power value, the value should be entered in dB."
|
|
::= { aprisaXETransmitter 8 }
|
|
|
|
aprisaXETransmitterAGC OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The Automatic Gain Control value in millivolts."
|
|
::= { aprisaXETransmitter 9 }
|
|
|
|
aprisaXETransmitterForwardPower OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The forward power measurement value in millivolts."
|
|
::= { aprisaXETransmitter 10 }
|
|
|
|
aprisaXETransmitterReversePower OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The reverse power value in millivolts."
|
|
::= { aprisaXETransmitter 11 }
|
|
|
|
aprisaXETransmitterTemperature OBJECT-TYPE
|
|
SYNTAX FourRFTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The temperature value in degrees Celcius."
|
|
::= { aprisaXETransmitter 12 }
|
|
|
|
aprisaXETransmitterVTune OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The voltage output from TX synth."
|
|
::= { aprisaXETransmitter 13 }
|
|
|
|
aprisaXETransmitter28VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 28V supply rail value in millivolts."
|
|
::= { aprisaXETransmitter 14 }
|
|
|
|
aprisaXETransmitter11VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 11V supply rail value in millivolts."
|
|
::= { aprisaXETransmitter 15 }
|
|
|
|
aprisaXETransmitter5VDigitalSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 5V digital supply rail value in millivolts."
|
|
::= { aprisaXETransmitter 16 }
|
|
|
|
aprisaXETransmitter7VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 7V RF supply rail value in millivolts."
|
|
::= { aprisaXETransmitter 17 }
|
|
|
|
aprisaXETransmitter9VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 9V supply synthesiser rail value in millivolts."
|
|
::= { aprisaXETransmitter 18 }
|
|
|
|
aprisaXETransmitterCharacterisationDataStatus OBJECT-TYPE
|
|
SYNTAX AprisaXEDataStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter characterisation data."
|
|
::= { aprisaXETransmitter 19 }
|
|
|
|
aprisaXETransmitterSerialNumber OBJECT-TYPE
|
|
SYNTAX FourRFSerialNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The unique module serial number for the transmitter."
|
|
::= { aprisaXETransmitter 20 }
|
|
|
|
aprisaXETransmitterReturnLoss OBJECT-TYPE
|
|
SYNTAX AprisaXEDbValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The return loss for the transmitter."
|
|
::= { aprisaXETransmitter 21 }
|
|
|
|
aprisaXETransmitterMibDataStatus OBJECT-TYPE
|
|
SYNTAX AprisaXEDataStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter MIB data."
|
|
::= { aprisaXETransmitter 22 }
|
|
|
|
aprisaXETransmitterADCChZero OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch zero voltage."
|
|
::= { aprisaXETransmitter 23 }
|
|
|
|
aprisaXETransmitterADCChOne OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch one voltage."
|
|
::= { aprisaXETransmitter 24 }
|
|
|
|
aprisaXETransmitterADCChTwo OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch two voltage."
|
|
::= { aprisaXETransmitter 25 }
|
|
|
|
aprisaXETransmitterADCChThree OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch three voltage."
|
|
::= { aprisaXETransmitter 26 }
|
|
|
|
aprisaXETransmitterADCChFour OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch four voltage."
|
|
::= { aprisaXETransmitter 27 }
|
|
|
|
aprisaXETransmitterADCChFive OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch five voltage."
|
|
::= { aprisaXETransmitter 28 }
|
|
|
|
aprisaXETransmitterADCChSix OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch six voltage."
|
|
::= { aprisaXETransmitter 29 }
|
|
|
|
aprisaXETransmitterADCChSeven OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch seven voltage."
|
|
::= { aprisaXETransmitter 30 }
|
|
|
|
aprisaXETransmitterADCChEight OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch eight voltage."
|
|
::= { aprisaXETransmitter 31 }
|
|
|
|
aprisaXETransmitterADCChNine OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch nine voltage."
|
|
::= { aprisaXETransmitter 32 }
|
|
|
|
aprisaXETransmitterADCChTen OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch ten voltage."
|
|
::= { aprisaXETransmitter 33 }
|
|
|
|
aprisaXETransmitterADCChEleven OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The TX adc ch eleven voltage."
|
|
::= { aprisaXETransmitter 34 }
|
|
|
|
aprisaXETransmitterNeg5VPowerStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter Negative 5V power supply."
|
|
::= { aprisaXETransmitter 35 }
|
|
|
|
aprisaXETransmitterAmplifierBalanceStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter Balanced Power Amplifier."
|
|
::= { aprisaXETransmitter 36 }
|
|
|
|
aprisaXETransmitterTcxoAdjustment OBJECT-TYPE
|
|
SYNTAX INTEGER { txTCXOAdjustmentPosFive (0),
|
|
txTCXOAdjustmentPosOne (1),
|
|
txTCXOAdjustmentZero (2),
|
|
txTCXOAdjustmentNegOne (3),
|
|
txTCXOAdjustmentNegFive (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The TX TCXO adjustment to be made by the customer, to
|
|
tune the TCXO. This is a shift in DAC steps."
|
|
::= { aprisaXETransmitter 37 }
|
|
|
|
aprisaXETransmitterSynthFileVersion OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..999 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the Synth File loaded from the filesystem."
|
|
::= { aprisaXETransmitter 38 }
|
|
|
|
aprisaXETransmitterOperationalDataVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the operational data for the transmitter."
|
|
::= { aprisaXETransmitter 39 }
|
|
|
|
aprisaXETransmitterSwCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..999 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The transmitter software compatibility number."
|
|
::= { aprisaXETransmitter 40 }
|
|
|
|
aprisaXETransmitterGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETransmitterStatus,
|
|
aprisaXETransmitterCommand,
|
|
aprisaXETransmitterSynthesiserStatus,
|
|
aprisaXETransmitter5VPowerStatus,
|
|
aprisaXETransmitter11VPowerStatus,
|
|
aprisaXETransmitter28VPowerStatus,
|
|
aprisaXETransmitterFrequency,
|
|
aprisaXETransmitterPower,
|
|
aprisaXETransmitterAGC,
|
|
aprisaXETransmitterForwardPower,
|
|
aprisaXETransmitterReversePower,
|
|
aprisaXETransmitterTemperature,
|
|
aprisaXETransmitterVTune,
|
|
aprisaXETransmitter28VSupply,
|
|
aprisaXETransmitter11VSupply,
|
|
aprisaXETransmitter5VDigitalSupply,
|
|
aprisaXETransmitter7VSupply,
|
|
aprisaXETransmitter9VSupply,
|
|
aprisaXETransmitterCharacterisationDataStatus,
|
|
aprisaXETransmitterSerialNumber,
|
|
aprisaXETransmitterReturnLoss,
|
|
aprisaXETransmitterMibDataStatus,
|
|
aprisaXETransmitterADCChZero,
|
|
aprisaXETransmitterADCChOne,
|
|
aprisaXETransmitterADCChTwo,
|
|
aprisaXETransmitterADCChThree,
|
|
aprisaXETransmitterADCChFour,
|
|
aprisaXETransmitterADCChFive,
|
|
aprisaXETransmitterADCChSix,
|
|
aprisaXETransmitterADCChSeven,
|
|
aprisaXETransmitterADCChEight,
|
|
aprisaXETransmitterADCChNine,
|
|
aprisaXETransmitterADCChTen,
|
|
aprisaXETransmitterADCChEleven,
|
|
aprisaXETransmitterNeg5VPowerStatus,
|
|
aprisaXETransmitterAmplifierBalanceStatus,
|
|
aprisaXETransmitterTcxoAdjustment,
|
|
aprisaXETransmitterSynthFileVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE transmitter settings group."
|
|
::= { aprisaXEGroups 36 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Transmitter
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Receiver - there is only one Receiver for each AprisaXE
|
|
--
|
|
-- NB: The units for all fields need to be confirmed
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEReceiver OBJECT IDENTIFIER ::= { aprisaXEObjects 51 }
|
|
|
|
aprisaXEReceiverStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { receiverOff (0),
|
|
receiverOn (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the receiver, currently the receiver can be On/Off
|
|
and the loopback can be On/Off."
|
|
::= { aprisaXEReceiver 1 }
|
|
|
|
aprisaXEReceiverCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
receiverOff (1),
|
|
receiverOn (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Commands used to control the receiver, currently the receiver can
|
|
be switched on and off and the loopback option switched on and off."
|
|
::= { aprisaXEReceiver 2 }
|
|
|
|
aprisaXEReceiverSynthesiserStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver synthesiser."
|
|
::= { aprisaXEReceiver 3 }
|
|
|
|
aprisaXEReceiver12VPowerStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the Receiver 12V power supply."
|
|
::= { aprisaXEReceiver 4 }
|
|
|
|
aprisaXEReceiverFrequency OBJECT-TYPE
|
|
SYNTAX FourRFFrequency
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The terminal transmit frequency in MHz. The possible bands are:
|
|
330 to 400 MHz (300 MHz)
|
|
400 to 470 MHz (400 MHz)
|
|
1350 to 1550 MHz (1400 MHz)
|
|
The frequency value should be supplied in Hz."
|
|
::= { aprisaXEReceiver 5 }
|
|
|
|
aprisaXEReceiverRSSI OBJECT-TYPE
|
|
SYNTAX FourRFRSSI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The characterised RSSI Voltage."
|
|
::= { aprisaXEReceiver 6 }
|
|
|
|
aprisaXEReceiverTemperature OBJECT-TYPE
|
|
SYNTAX FourRFTemperature
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The temperature value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 8 }
|
|
|
|
aprisaXEReceiverVTune OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The voltage output from RX synth value, this should only be
|
|
accessible in engineering mode."
|
|
::= { aprisaXEReceiver 9 }
|
|
|
|
aprisaXEReceiver9VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 9V supply rail value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 10 }
|
|
|
|
aprisaXEReceiver5VSupply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 5V supply rail value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 11 }
|
|
|
|
aprisaXEReceiverModemAGC OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The modem AGC, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 12 }
|
|
|
|
aprisaXEReceiverNeg1V5Supply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The -1.5V supply rail value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 13 }
|
|
|
|
aprisaXEReceiver3V3Supply OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The 3.3V supply rail value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 14 }
|
|
|
|
aprisaXEReceiverDacTest OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The DacTest value, this should only be accessible in
|
|
engineering mode."
|
|
::= { aprisaXEReceiver 15 }
|
|
|
|
aprisaXEReceiverCharacterisationDataStatus OBJECT-TYPE
|
|
SYNTAX AprisaXEDataStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver characterisation data."
|
|
::= { aprisaXEReceiver 16 }
|
|
|
|
aprisaXEReceiverSerialNumber OBJECT-TYPE
|
|
SYNTAX FourRFSerialNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The unique module serial number for the receiver."
|
|
::= { aprisaXEReceiver 17 }
|
|
|
|
aprisaXEReceiverRfLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enables and disabled RF loopback."
|
|
::= { aprisaXEReceiver 18 }
|
|
|
|
aprisaXEReceiverRfLoopbackTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The number of seconds after which RF loopback should timeout."
|
|
::= { aprisaXEReceiver 19 }
|
|
|
|
aprisaXEReceiverMibDataStatus OBJECT-TYPE
|
|
SYNTAX AprisaXEDataStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver MIB data."
|
|
::= { aprisaXEReceiver 20 }
|
|
|
|
aprisaXEReceiverADCChZero OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch zero voltage."
|
|
::= { aprisaXEReceiver 21 }
|
|
|
|
aprisaXEReceiverADCChOne OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch one voltage."
|
|
::= { aprisaXEReceiver 22 }
|
|
|
|
aprisaXEReceiverADCChTwo OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch two voltage."
|
|
::= { aprisaXEReceiver 23 }
|
|
|
|
aprisaXEReceiverADCChThree OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch three voltage."
|
|
::= { aprisaXEReceiver 24 }
|
|
|
|
aprisaXEReceiverADCChFour OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch four voltage."
|
|
::= { aprisaXEReceiver 25 }
|
|
|
|
aprisaXEReceiverADCChFive OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch five voltage."
|
|
::= { aprisaXEReceiver 26 }
|
|
|
|
aprisaXEReceiverADCChSix OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch six voltage."
|
|
::= { aprisaXEReceiver 27 }
|
|
|
|
aprisaXEReceiverADCChSeven OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch seven voltage."
|
|
::= { aprisaXEReceiver 28 }
|
|
|
|
aprisaXEReceiverADCChEight OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch eight voltage."
|
|
::= { aprisaXEReceiver 29 }
|
|
|
|
aprisaXEReceiverADCChNine OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch nine voltage."
|
|
::= { aprisaXEReceiver 30 }
|
|
|
|
aprisaXEReceiverADCChTen OBJECT-TYPE
|
|
SYNTAX AprisaXEAdcVoltage
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The RX adc ch ten voltage."
|
|
::= { aprisaXEReceiver 31 }
|
|
|
|
aprisaXEReceiverRSSIThresQPSKLowerOn OBJECT-TYPE
|
|
SYNTAX Integer32(-110..-40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The QPSK Lower ON RSSI Threshold."
|
|
::= { aprisaXEReceiver 32 }
|
|
|
|
aprisaXEReceiverRSSIThres16QAMLowerOn OBJECT-TYPE
|
|
SYNTAX Integer32(-110..-40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The 16QAM Lower ON RSSI Threshold."
|
|
::= { aprisaXEReceiver 33 }
|
|
|
|
aprisaXEReceiverRSSIThres32QAMLowerOn OBJECT-TYPE
|
|
SYNTAX Integer32(-110..-40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The 32QAM Lower ON RSSI Threshold."
|
|
::= { aprisaXEReceiver 34 }
|
|
|
|
aprisaXEReceiverRSSIThres64QAMLowerOn OBJECT-TYPE
|
|
SYNTAX Integer32(-110..-40)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The 64QAM Lower ON RSSI Threshold."
|
|
::= { aprisaXEReceiver 35 }
|
|
|
|
aprisaXEReceiverSynthFileVersion OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..999 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the Synth File loaded from the filesystem."
|
|
::= { aprisaXEReceiver 36 }
|
|
|
|
aprisaXEReceiverOperationalDataVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The version of the operational data of the receiver."
|
|
::= { aprisaXEReceiver 37 }
|
|
|
|
aprisaXEReceiverSwCompatibility OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..999 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The receiver software compatibility number."
|
|
::= { aprisaXEReceiver 38 }
|
|
|
|
aprisaXETReceiverGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEReceiverStatus,
|
|
aprisaXEReceiverCommand,
|
|
aprisaXEReceiverSynthesiserStatus,
|
|
aprisaXEReceiver12VPowerStatus,
|
|
aprisaXEReceiverFrequency,
|
|
aprisaXEReceiverRSSI,
|
|
aprisaXEReceiverTemperature,
|
|
aprisaXEReceiverVTune,
|
|
aprisaXEReceiver9VSupply,
|
|
aprisaXEReceiver5VSupply,
|
|
aprisaXEReceiverModemAGC,
|
|
aprisaXEReceiverNeg1V5Supply,
|
|
aprisaXEReceiver3V3Supply,
|
|
aprisaXEReceiverDacTest,
|
|
aprisaXEReceiverCharacterisationDataStatus,
|
|
aprisaXEReceiverSerialNumber,
|
|
aprisaXEReceiverRfLoopback,
|
|
aprisaXEReceiverRfLoopbackTimeout,
|
|
aprisaXEReceiverMibDataStatus,
|
|
aprisaXEReceiverADCChZero,
|
|
aprisaXEReceiverADCChOne,
|
|
aprisaXEReceiverADCChTwo,
|
|
aprisaXEReceiverADCChThree,
|
|
aprisaXEReceiverADCChFour,
|
|
aprisaXEReceiverADCChFive,
|
|
aprisaXEReceiverADCChSix,
|
|
aprisaXEReceiverADCChSeven,
|
|
aprisaXEReceiverADCChEight,
|
|
aprisaXEReceiverADCChNine,
|
|
aprisaXEReceiverADCChTen,
|
|
aprisaXEReceiverRSSIThresQPSKLowerOn,
|
|
aprisaXEReceiverRSSIThres16QAMLowerOn,
|
|
aprisaXEReceiverRSSIThres32QAMLowerOn,
|
|
aprisaXEReceiverRSSIThres64QAMLowerOn,
|
|
aprisaXEReceiverSynthFileVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE Receiver settings group."
|
|
::= { aprisaXEGroups 46 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Receiver
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Modem - there is only one Modem for each AprisaXE
|
|
--
|
|
-- NB: The units for all fields need to be confirmed
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEModem OBJECT IDENTIFIER ::= { aprisaXEObjects 61 }
|
|
|
|
aprisaXEModemDemodAligmentStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the demodulator alignment."
|
|
::= { aprisaXEModem 1 }
|
|
|
|
aprisaXEModemTdmAligmentStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the TDM alignment."
|
|
::= { aprisaXEModem 2 }
|
|
|
|
aprisaXEModemRefAStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the REFa clock."
|
|
::= { aprisaXEModem 3 }
|
|
|
|
aprisaXEModemRefBStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the REFb clock."
|
|
::= { aprisaXEModem 4 }
|
|
|
|
aprisaXEModemUncorrectableBlockCount OBJECT-TYPE
|
|
SYNTAX FourRFErrorCounter
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Count of uncorrectable blocks since last read."
|
|
::= { aprisaXEModem 5 }
|
|
|
|
aprisaXEModemIQData OBJECT-TYPE
|
|
SYNTAX AprisaXEIQData
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A list of I/Q data pairs, this is a sequence of byes values
|
|
the first byte is an I value, the second a Q value."
|
|
::= { aprisaXEModem 6 }
|
|
|
|
aprisaXEModemSyncStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the link lock."
|
|
::= { aprisaXEModem 7 }
|
|
|
|
aprisaXEModemFreqOffsetEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { offsetDisabled (0),
|
|
offsetEnabled (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Turn the Modulator frequency offset of 50kHz on or off."
|
|
::= { aprisaXEModem 8 }
|
|
|
|
aprisaXEModemInterleaverEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { interleaverEnabled (100),
|
|
interleaverDisabled (101),
|
|
interleaverDefault (102)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Interleaver being used on the modem. Trade off
|
|
between link latency and FEC performance."
|
|
::= { aprisaXEModem 9 }
|
|
|
|
aprisaXEModemQPSKCoding OBJECT-TYPE
|
|
SYNTAX INTEGER { grayCoded (0),
|
|
nonGrayCoded (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Encoding and Decoding being used for QPSK. Can be either
|
|
Gray coded or non Gray coded."
|
|
::= { aprisaXEModem 10 }
|
|
|
|
aprisaXEModemConfigVersion OBJECT-TYPE
|
|
SYNTAX INTEGER ( 0..999 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Modem Configuration file version."
|
|
::= { aprisaXEModem 11 }
|
|
|
|
aprisaXEModemGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEModemDemodAligmentStatus,
|
|
aprisaXEModemTdmAligmentStatus,
|
|
aprisaXEModemRefAStatus,
|
|
aprisaXEModemRefBStatus,
|
|
aprisaXEModemUncorrectableBlockCount,
|
|
aprisaXEModemIQData,
|
|
aprisaXEModemSyncStatus,
|
|
aprisaXEModemFreqOffsetEnable,
|
|
aprisaXEModemInterleaverEnable,
|
|
aprisaXEModemQPSKCoding,
|
|
aprisaXEModemConfigVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE Modem settings group."
|
|
::= { aprisaXEGroups 53 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Modem
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- BoardTable - Table for storing basic per slot details.
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table stores the basic information for the plugin slots."
|
|
::= { aprisaXEObjects 66 }
|
|
|
|
aprisaXEBoardEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Slot Information."
|
|
INDEX { aprisaXEBoardSlot }
|
|
::= { aprisaXEBoardTable 1 }
|
|
|
|
-- Each table entry consists of the type of the card in the slot,
|
|
-- the hardware and firmware version numbers and the hardware software
|
|
-- compatibility number.
|
|
|
|
AprisaXEBoardEntry ::= SEQUENCE {
|
|
aprisaXEBoardSlot INTEGER,
|
|
aprisaXEBoardType INTEGER,
|
|
aprisaXEExpectedBoardType INTEGER,
|
|
aprisaXEBoardHardwareVersion INTEGER,
|
|
aprisaXEBoardFirmwareVersion INTEGER,
|
|
aprisaXEBoardHSCNumber INTEGER,
|
|
aprisaXEBoardSerialNumber OCTET STRING
|
|
}
|
|
|
|
aprisaXEBoardSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The slot number in which the board resides, the physical slots are
|
|
numbered from zero to ten and mapped to one to eleven in the MIB.
|
|
The motherboard is therefore in physical slot 0 but MIB slot 1."
|
|
::= { aprisaXEBoardEntry 1 }
|
|
|
|
aprisaXEBoardType OBJECT-TYPE
|
|
SYNTAX AprisaXECardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The type of the board in the slot. The types are as follows:
|
|
- none : there is no card in the slot
|
|
- modem : this card will be fitted in physical slot 0
|
|
- transmitter : the transmitter card, this will be in physical slot 9
|
|
- receiver : the receiver card, this will be in physical slot 10
|
|
- quadJET : e1/t1 4 port card"
|
|
::= { aprisaXEBoardEntry 2 }
|
|
|
|
aprisaXEExpectedBoardType OBJECT-TYPE
|
|
SYNTAX AprisaXECardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The type of the board expected in the slot. The types are as follows:
|
|
- none : there is no card in the slot
|
|
- modem : this card will be fitted in physical slot 0
|
|
- transmitter : the transmitter card, this will be in physical slot 9
|
|
- receiver : the receiver card, this will be in physical slot 10
|
|
- quadJET : e1/t1 4 port card"
|
|
::= { aprisaXEBoardEntry 3 }
|
|
|
|
aprisaXEBoardHardwareVersion OBJECT-TYPE
|
|
SYNTAX AprisaXEHardwareVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Field indicating the hardware version for the board in the slot."
|
|
::= { aprisaXEBoardEntry 4 }
|
|
|
|
aprisaXEBoardFirmwareVersion OBJECT-TYPE
|
|
SYNTAX AprisaXEHardwareVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Field indicating the firmware version for the board in the slot."
|
|
::= { aprisaXEBoardEntry 5 }
|
|
|
|
aprisaXEBoardHSCNumber OBJECT-TYPE
|
|
SYNTAX AprisaXEHardwareVersion
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Field indicating the hardware software configuration number
|
|
for the board in the slot."
|
|
::= { aprisaXEBoardEntry 6 }
|
|
|
|
aprisaXEBoardSerialNumber OBJECT-TYPE
|
|
SYNTAX FourRFSerialNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Field indicating the module serial number for the card in the slot."
|
|
::= { aprisaXEBoardEntry 7 }
|
|
|
|
-- ***************************************************************************
|
|
-- End BoardTable
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Alarms - notifications should be defined for each alarm.
|
|
--
|
|
-- Each alarm has at least three components:
|
|
-- Its current status noAlarm or alarmPresent indicating whether the alarm
|
|
-- is present or not.
|
|
--
|
|
-- The alarm severity indicating whether the alarm is major or minor (or
|
|
-- anything else we want)
|
|
--
|
|
-- A flag indicating whether the alarm is enabled
|
|
-- (all alarms are enabled by default)
|
|
--
|
|
-- Currently all objects are read-only and would be configured from the
|
|
-- MIB configuration at startup it is possible to allow the user to change
|
|
-- the severity and to enable and disable alarms if this is considered useful.
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXELinkAlarms OBJECT IDENTIFIER ::= { aprisaXEObjects 86 }
|
|
|
|
-- ***************************************************************************
|
|
-- The Transmitter Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXETransmitterAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 1 }
|
|
|
|
|
|
--
|
|
-- Forward Power High Alarm
|
|
--
|
|
-- This is a minor alarm
|
|
--
|
|
|
|
aprisaXEForwardPowerHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 1 }
|
|
|
|
aprisaXEForwardPowerHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the forward power too high alarm."
|
|
::= { aprisaXEForwardPowerHiAlarm 1 }
|
|
|
|
aprisaXEForwardPowerHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the forward power too high alarm."
|
|
::= { aprisaXEForwardPowerHiAlarm 2 }
|
|
|
|
aprisaXEForwardPowerHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the forward power too high alarm is enabled."
|
|
::= { aprisaXEForwardPowerHiAlarm 3 }
|
|
|
|
aprisaXEForwardPowerHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the forward power too high
|
|
alarm will be set."
|
|
::= { aprisaXEForwardPowerHiAlarm 4 }
|
|
|
|
aprisaXEForwardPowerHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the forward power alarm
|
|
will be cleared."
|
|
::= { aprisaXEForwardPowerHiAlarm 5 }
|
|
|
|
aprisaXEForwardPowerHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEForwardPowerHiAlarmStatus,
|
|
aprisaXEForwardPowerHiAlarmSeverity,
|
|
aprisaXEForwardPowerHiAlarmEnabled,
|
|
aprisaXEForwardPowerHiAlarmThreshold,
|
|
aprisaXEForwardPowerHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE forward power too high alarm group."
|
|
::= { aprisaXEGroups 56 }
|
|
|
|
|
|
--
|
|
-- Forward Power Low Alarm
|
|
--
|
|
-- This is a minor alarm
|
|
--
|
|
|
|
aprisaXEForwardPowerLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 2 }
|
|
|
|
aprisaXEForwardPowerLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the forward power too low alarm."
|
|
::= { aprisaXEForwardPowerLoAlarm 1 }
|
|
|
|
aprisaXEForwardPowerLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the forward power too low alarm."
|
|
::= { aprisaXEForwardPowerLoAlarm 2 }
|
|
|
|
aprisaXEForwardPowerLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the forward power too low alarm is enabled."
|
|
::= { aprisaXEForwardPowerLoAlarm 3 }
|
|
|
|
aprisaXEForwardPowerLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the forward power too low alarm
|
|
will be set."
|
|
::= { aprisaXEForwardPowerLoAlarm 4 }
|
|
|
|
aprisaXEForwardPowerLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the forward power too low alarm
|
|
will be cleared."
|
|
::= { aprisaXEForwardPowerLoAlarm 5 }
|
|
|
|
aprisaXEForwardPowerLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEForwardPowerLoAlarmStatus,
|
|
aprisaXEForwardPowerLoAlarmSeverity,
|
|
aprisaXEForwardPowerLoAlarmEnabled,
|
|
aprisaXEForwardPowerLoAlarmThreshold,
|
|
aprisaXEForwardPowerLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE forward power low alarm group."
|
|
::= { aprisaXEGroups 61 }
|
|
|
|
|
|
--
|
|
-- Reverse Power Too High Alarm
|
|
--
|
|
|
|
aprisaXEReversePowerHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 3 }
|
|
|
|
aprisaXEReversePowerHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the reverse power out of limits alarm."
|
|
::= { aprisaXEReversePowerHiAlarm 1 }
|
|
|
|
aprisaXEReversePowerHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the reverse power out of limits alarm."
|
|
::= { aprisaXEReversePowerHiAlarm 2 }
|
|
|
|
aprisaXEReversePowerHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the reverse power out of limits alarm is enabled."
|
|
::= { aprisaXEReversePowerHiAlarm 3 }
|
|
|
|
aprisaXEReversePowerHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the reverse power alarm will be set."
|
|
::= { aprisaXEReversePowerHiAlarm 4 }
|
|
|
|
aprisaXEReversePowerHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the reverse power alarm will be cleared."
|
|
::= { aprisaXEReversePowerHiAlarm 5 }
|
|
|
|
aprisaXEReversePowerHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEReversePowerHiAlarmStatus,
|
|
aprisaXEReversePowerHiAlarmSeverity,
|
|
aprisaXEReversePowerHiAlarmEnabled,
|
|
aprisaXEReversePowerHiAlarmThreshold,
|
|
aprisaXEReversePowerHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE reverse power too high alarm group."
|
|
::= { aprisaXEGroups 66 }
|
|
|
|
|
|
--
|
|
-- Reverse Power Too Low Alarm
|
|
--
|
|
|
|
aprisaXEReversePowerLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 4 }
|
|
|
|
aprisaXEReversePowerLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the reverse power out of limits alarm."
|
|
::= { aprisaXEReversePowerLoAlarm 1 }
|
|
|
|
aprisaXEReversePowerLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the reverse power out of limits alarm."
|
|
::= { aprisaXEReversePowerLoAlarm 2 }
|
|
|
|
aprisaXEReversePowerLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the reverse power out of limits alarm is enabled."
|
|
::= { aprisaXEReversePowerLoAlarm 3 }
|
|
|
|
aprisaXEReversePowerLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the reverse power alarm will be set."
|
|
::= { aprisaXEReversePowerLoAlarm 4 }
|
|
|
|
aprisaXEReversePowerLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the reverse power alarm will be cleared."
|
|
::= { aprisaXEReversePowerLoAlarm 5 }
|
|
|
|
aprisaXEReversePowerLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEReversePowerLoAlarmStatus,
|
|
aprisaXEReversePowerLoAlarmSeverity,
|
|
aprisaXEReversePowerLoAlarmEnabled,
|
|
aprisaXEReversePowerLoAlarmThreshold,
|
|
aprisaXEReversePowerLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE reverse power too low alarm group."
|
|
::= { aprisaXEGroups 71 }
|
|
|
|
|
|
--
|
|
-- Transmitter PA Temperature Alarm
|
|
--
|
|
-- This alarm is raised when the transmitter temperature exceeds a defined
|
|
-- threshold. This is a major alarm as the transmitter will be switched off
|
|
-- when this alarm is present.
|
|
--
|
|
|
|
aprisaXETxPaTempAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 5 }
|
|
|
|
aprisaXETxPaTempAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter temperature too high alarm."
|
|
::= { aprisaXETxPaTempAlarm 1 }
|
|
|
|
aprisaXETxPaTempAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter temperature too high alarm."
|
|
::= { aprisaXETxPaTempAlarm 2 }
|
|
|
|
aprisaXETxPaTempAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter temperature too high alarm is enabled."
|
|
::= { aprisaXETxPaTempAlarm 3 }
|
|
|
|
aprisaXETxPaTempAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter temperature too high
|
|
alarm will be set."
|
|
::= { aprisaXETxPaTempAlarm 4 }
|
|
|
|
aprisaXETxPaTempAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter temperature too high
|
|
will be cleared."
|
|
::= { aprisaXETxPaTempAlarm 5 }
|
|
|
|
aprisaXETxPaTempAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxPaTempAlarmStatus,
|
|
aprisaXETxPaTempAlarmSeverity,
|
|
aprisaXETxPaTempAlarmEnabled,
|
|
aprisaXETxPaTempAlarmThreshold,
|
|
aprisaXETxPaTempAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter temperature too high alarm group."
|
|
::= { aprisaXEGroups 76 }
|
|
|
|
|
|
aprisaXETxPaTempWarnAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 6 }
|
|
|
|
aprisaXETxPaTempWarnAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter temperature warning alarm."
|
|
::= { aprisaXETxPaTempWarnAlarm 1 }
|
|
|
|
aprisaXETxPaTempWarnAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter temperature warning alarm."
|
|
::= { aprisaXETxPaTempWarnAlarm 2 }
|
|
|
|
aprisaXETxPaTempWarnAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter temperature warning alarm is enabled."
|
|
::= { aprisaXETxPaTempWarnAlarm 3 }
|
|
|
|
aprisaXETxPaTempWarnAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter temperature warning
|
|
alarm will be set."
|
|
::= { aprisaXETxPaTempWarnAlarm 4 }
|
|
|
|
aprisaXETxPaTempWarnAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter temperature warning
|
|
will be cleared."
|
|
::= { aprisaXETxPaTempWarnAlarm 5 }
|
|
|
|
aprisaXETxPaTempWarnAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxPaTempWarnAlarmStatus,
|
|
aprisaXETxPaTempWarnAlarmSeverity,
|
|
aprisaXETxPaTempWarnAlarmEnabled,
|
|
aprisaXETxPaTempWarnAlarmThreshold,
|
|
aprisaXETxPaTempWarnAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter temperature warning alarm group."
|
|
::= { aprisaXEGroups 81 }
|
|
|
|
|
|
aprisaXETxAgcHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 7 }
|
|
|
|
aprisaXETxAgcHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter AGC too high alarm."
|
|
::= { aprisaXETxAgcHiAlarm 1 }
|
|
|
|
aprisaXETxAgcHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter AGC too high alarm."
|
|
::= { aprisaXETxAgcHiAlarm 2 }
|
|
|
|
aprisaXETxAgcHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter AGC too high alarm is enabled."
|
|
::= { aprisaXETxAgcHiAlarm 3 }
|
|
|
|
aprisaXETxAgcHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter AGC too high
|
|
alarm will be set."
|
|
::= { aprisaXETxAgcHiAlarm 4 }
|
|
|
|
aprisaXETxAgcHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter AGC too high
|
|
will be cleared."
|
|
::= { aprisaXETxAgcHiAlarm 5 }
|
|
|
|
aprisaXETxAgcHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxAgcHiAlarmStatus,
|
|
aprisaXETxAgcHiAlarmSeverity,
|
|
aprisaXETxAgcHiAlarmEnabled,
|
|
aprisaXETxAgcHiAlarmThreshold,
|
|
aprisaXETxAgcHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter AGC too high alarm group."
|
|
::= { aprisaXEGroups 86 }
|
|
|
|
|
|
aprisaXETxAgcLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 8 }
|
|
|
|
aprisaXETxAgcLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter AGC too low alarm."
|
|
::= { aprisaXETxAgcLoAlarm 1 }
|
|
|
|
aprisaXETxAgcLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter AGC too low alarm."
|
|
::= { aprisaXETxAgcLoAlarm 2 }
|
|
|
|
aprisaXETxAgcLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter AGC too low alarm is enabled."
|
|
::= { aprisaXETxAgcLoAlarm 3 }
|
|
|
|
aprisaXETxAgcLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter AGC too low
|
|
alarm will be set."
|
|
::= { aprisaXETxAgcLoAlarm 4 }
|
|
|
|
aprisaXETxAgcLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter AGC too low
|
|
will be cleared."
|
|
::= { aprisaXETxAgcLoAlarm 5 }
|
|
|
|
aprisaXETxAgcLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxAgcLoAlarmStatus,
|
|
aprisaXETxAgcLoAlarmSeverity,
|
|
aprisaXETxAgcLoAlarmEnabled,
|
|
aprisaXETxAgcLoAlarmThreshold,
|
|
aprisaXETxAgcLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter AGC too low alarm group."
|
|
::= { aprisaXEGroups 91 }
|
|
|
|
|
|
aprisaXETxVtuneHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 9 }
|
|
|
|
aprisaXETxVtuneHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter VTUNE too high alarm."
|
|
::= { aprisaXETxVtuneHiAlarm 1 }
|
|
|
|
aprisaXETxVtuneHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter VTUNE too high alarm."
|
|
::= { aprisaXETxVtuneHiAlarm 2 }
|
|
|
|
aprisaXETxVtuneHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter VTUNE too high alarm is enabled."
|
|
::= { aprisaXETxVtuneHiAlarm 3 }
|
|
|
|
aprisaXETxVtuneHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter VTUNE too high
|
|
alarm will be set."
|
|
::= { aprisaXETxVtuneHiAlarm 4 }
|
|
|
|
aprisaXETxVtuneHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter VTUNE too high
|
|
will be cleared."
|
|
::= { aprisaXETxVtuneHiAlarm 5 }
|
|
|
|
aprisaXETxVtuneHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxVtuneHiAlarmStatus,
|
|
aprisaXETxVtuneHiAlarmSeverity,
|
|
aprisaXETxVtuneHiAlarmEnabled,
|
|
aprisaXETxVtuneHiAlarmThreshold,
|
|
aprisaXETxVtuneHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter VTUNE too high alarm group."
|
|
::= { aprisaXEGroups 96 }
|
|
|
|
|
|
aprisaXETxVtuneLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 10 }
|
|
|
|
aprisaXETxVtuneLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter VTUNE too low alarm."
|
|
::= { aprisaXETxVtuneLoAlarm 1 }
|
|
|
|
aprisaXETxVtuneLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter VTUNE too low alarm."
|
|
::= { aprisaXETxVtuneLoAlarm 2 }
|
|
|
|
aprisaXETxVtuneLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter VTUNE too low alarm is enabled."
|
|
::= { aprisaXETxVtuneLoAlarm 3 }
|
|
|
|
aprisaXETxVtuneLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter VTUNE too low
|
|
alarm will be set."
|
|
::= { aprisaXETxVtuneLoAlarm 4 }
|
|
|
|
aprisaXETxVtuneLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter VTUNE too low
|
|
will be cleared."
|
|
::= { aprisaXETxVtuneLoAlarm 5 }
|
|
|
|
aprisaXETxVtuneLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxVtuneLoAlarmStatus,
|
|
aprisaXETxVtuneLoAlarmSeverity,
|
|
aprisaXETxVtuneLoAlarmEnabled,
|
|
aprisaXETxVtuneLoAlarmThreshold,
|
|
aprisaXETxVtuneLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter VTUNE too low alarm group."
|
|
::= { aprisaXEGroups 101 }
|
|
|
|
|
|
aprisaXETx5VDigHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 11 }
|
|
|
|
aprisaXETx5VDigHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 5V digital voltage too high alarm."
|
|
::= { aprisaXETx5VDigHiAlarm 1 }
|
|
|
|
aprisaXETx5VDigHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 5V digital voltage too high alarm."
|
|
::= { aprisaXETx5VDigHiAlarm 2 }
|
|
|
|
aprisaXETx5VDigHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 5V digital voltage too high alarm is enabled."
|
|
::= { aprisaXETx5VDigHiAlarm 3 }
|
|
|
|
aprisaXETx5VDigHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETx5VDigHiAlarm 4 }
|
|
|
|
aprisaXETx5VDigHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETx5VDigHiAlarm 5 }
|
|
|
|
aprisaXETx5VDigHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx5VDigHiAlarmStatus,
|
|
aprisaXETx5VDigHiAlarmSeverity,
|
|
aprisaXETx5VDigHiAlarmEnabled,
|
|
aprisaXETx5VDigHiAlarmThreshold,
|
|
aprisaXETx5VDigHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 5V digital voltage too high alarm group."
|
|
::= { aprisaXEGroups 106 }
|
|
|
|
|
|
aprisaXETx5VDigLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 12 }
|
|
|
|
aprisaXETx5VDigLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 5V digital voltage too low alarm."
|
|
::= { aprisaXETx5VDigLoAlarm 1 }
|
|
|
|
aprisaXETx5VDigLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 5V digital voltage too low alarm."
|
|
::= { aprisaXETx5VDigLoAlarm 2 }
|
|
|
|
aprisaXETx5VDigLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 5V digital voltage too low alarm is enabled."
|
|
::= { aprisaXETx5VDigLoAlarm 3 }
|
|
|
|
aprisaXETx5VDigLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETx5VDigLoAlarm 4 }
|
|
|
|
aprisaXETx5VDigLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 5V digital voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETx5VDigLoAlarm 5 }
|
|
|
|
aprisaXETx5VDigLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx5VDigLoAlarmStatus,
|
|
aprisaXETx5VDigLoAlarmSeverity,
|
|
aprisaXETx5VDigLoAlarmEnabled,
|
|
aprisaXETx5VDigLoAlarmThreshold,
|
|
aprisaXETx5VDigLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 5V digital voltage too low alarm group."
|
|
::= { aprisaXEGroups 111 }
|
|
|
|
|
|
aprisaXETx7VRfHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 13 }
|
|
|
|
aprisaXETx7VRfHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 7V RF voltage too high alarm."
|
|
::= { aprisaXETx7VRfHiAlarm 1 }
|
|
|
|
aprisaXETx7VRfHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 7V RF voltage too high alarm."
|
|
::= { aprisaXETx7VRfHiAlarm 2 }
|
|
|
|
aprisaXETx7VRfHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 7V RF voltage too high alarm is enabled."
|
|
::= { aprisaXETx7VRfHiAlarm 3 }
|
|
|
|
aprisaXETx7VRfHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETx7VRfHiAlarm 4 }
|
|
|
|
aprisaXETx7VRfHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETx7VRfHiAlarm 5 }
|
|
|
|
aprisaXETx7VRfHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx7VRfHiAlarmStatus,
|
|
aprisaXETx7VRfHiAlarmSeverity,
|
|
aprisaXETx7VRfHiAlarmEnabled,
|
|
aprisaXETx7VRfHiAlarmThreshold,
|
|
aprisaXETx7VRfHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 7V RF voltage too high alarm group."
|
|
::= { aprisaXEGroups 116 }
|
|
|
|
|
|
aprisaXETx7VRfLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 14 }
|
|
|
|
aprisaXETx7VRfLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 7V RF voltage too low alarm."
|
|
::= { aprisaXETx7VRfLoAlarm 1 }
|
|
|
|
aprisaXETx7VRfLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 7V RF voltage too low alarm."
|
|
::= { aprisaXETx7VRfLoAlarm 2 }
|
|
|
|
aprisaXETx7VRfLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 7V RF voltage too low alarm is enabled."
|
|
::= { aprisaXETx7VRfLoAlarm 3 }
|
|
|
|
aprisaXETx7VRfLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETx7VRfLoAlarm 4 }
|
|
|
|
aprisaXETx7VRfLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 7V RF voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETx7VRfLoAlarm 5 }
|
|
|
|
aprisaXETx7VRfLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx7VRfLoAlarmStatus,
|
|
aprisaXETx7VRfLoAlarmSeverity,
|
|
aprisaXETx7VRfLoAlarmEnabled,
|
|
aprisaXETx7VRfLoAlarmThreshold,
|
|
aprisaXETx7VRfLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 7V RF voltage too low alarm group."
|
|
::= { aprisaXEGroups 121 }
|
|
|
|
|
|
aprisaXETx9VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 15 }
|
|
|
|
aprisaXETx9VHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 9V voltage too high alarm."
|
|
::= { aprisaXETx9VHiAlarm 1 }
|
|
|
|
aprisaXETx9VHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 9V voltage too high alarm."
|
|
::= { aprisaXETx9VHiAlarm 2 }
|
|
|
|
aprisaXETx9VHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 9V voltage too high alarm is enabled."
|
|
::= { aprisaXETx9VHiAlarm 3 }
|
|
|
|
aprisaXETx9VHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 9V voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETx9VHiAlarm 4 }
|
|
|
|
aprisaXETx9VHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 9V voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETx9VHiAlarm 5 }
|
|
|
|
aprisaXETx9VHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx9VHiAlarmStatus,
|
|
aprisaXETx9VHiAlarmSeverity,
|
|
aprisaXETx9VHiAlarmEnabled,
|
|
aprisaXETx9VHiAlarmThreshold,
|
|
aprisaXETx9VHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 9V voltage too high alarm group."
|
|
::= { aprisaXEGroups 126 }
|
|
|
|
|
|
aprisaXETx9VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 16 }
|
|
|
|
aprisaXETx9VLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 9V voltage too low alarm."
|
|
::= { aprisaXETx9VLoAlarm 1 }
|
|
|
|
aprisaXETx9VLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 9V voltage too low alarm."
|
|
::= { aprisaXETx9VLoAlarm 2 }
|
|
|
|
aprisaXETx9VLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 9V voltage too low alarm is enabled."
|
|
::= { aprisaXETx9VLoAlarm 3 }
|
|
|
|
aprisaXETx9VLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 9V voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETx9VLoAlarm 4 }
|
|
|
|
aprisaXETx9VLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 9V voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETx9VLoAlarm 5 }
|
|
|
|
aprisaXETx9VLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx9VLoAlarmStatus,
|
|
aprisaXETx9VLoAlarmSeverity,
|
|
aprisaXETx9VLoAlarmEnabled,
|
|
aprisaXETx9VLoAlarmThreshold,
|
|
aprisaXETx9VLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 9V voltage too low alarm group."
|
|
::= { aprisaXEGroups 131 }
|
|
|
|
|
|
aprisaXETx11VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 17 }
|
|
|
|
aprisaXETx11VHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 11V voltage too high alarm."
|
|
::= { aprisaXETx11VHiAlarm 1 }
|
|
|
|
aprisaXETx11VHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 11V voltage too high alarm."
|
|
::= { aprisaXETx11VHiAlarm 2 }
|
|
|
|
aprisaXETx11VHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 11V voltage too high alarm is enabled."
|
|
::= { aprisaXETx11VHiAlarm 3 }
|
|
|
|
aprisaXETx11VHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 11V voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETx11VHiAlarm 4 }
|
|
|
|
aprisaXETx11VHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 11V voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETx11VHiAlarm 5 }
|
|
|
|
aprisaXETx11VHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx11VHiAlarmStatus,
|
|
aprisaXETx11VHiAlarmSeverity,
|
|
aprisaXETx11VHiAlarmEnabled,
|
|
aprisaXETx11VHiAlarmThreshold,
|
|
aprisaXETx11VHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 11V voltage too high alarm group."
|
|
::= { aprisaXEGroups 136 }
|
|
|
|
|
|
aprisaXETx11VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 18 }
|
|
|
|
aprisaXETx11VLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 11V voltage too low alarm."
|
|
::= { aprisaXETx11VLoAlarm 1 }
|
|
|
|
aprisaXETx11VLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 11V voltage too low alarm."
|
|
::= { aprisaXETx11VLoAlarm 2 }
|
|
|
|
aprisaXETx11VLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 11V voltage too low alarm is enabled."
|
|
::= { aprisaXETx11VLoAlarm 3 }
|
|
|
|
aprisaXETx11VLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 11V voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETx11VLoAlarm 4 }
|
|
|
|
aprisaXETx11VLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 11V voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETx11VLoAlarm 5 }
|
|
|
|
aprisaXETx11VLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx11VLoAlarmStatus,
|
|
aprisaXETx11VLoAlarmSeverity,
|
|
aprisaXETx11VLoAlarmEnabled,
|
|
aprisaXETx11VLoAlarmThreshold,
|
|
aprisaXETx11VLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 11V voltage too low alarm group."
|
|
::= { aprisaXEGroups 141 }
|
|
|
|
|
|
aprisaXETx28VHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 19 }
|
|
|
|
aprisaXETx28VHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 28V voltage too high alarm."
|
|
::= { aprisaXETx28VHiAlarm 1 }
|
|
|
|
aprisaXETx28VHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 28V voltage too high alarm."
|
|
::= { aprisaXETx28VHiAlarm 2 }
|
|
|
|
aprisaXETx28VHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 28V voltage too high alarm is enabled."
|
|
::= { aprisaXETx28VHiAlarm 3 }
|
|
|
|
aprisaXETx28VHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 28V voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETx28VHiAlarm 4 }
|
|
|
|
aprisaXETx28VHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 28V voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETx28VHiAlarm 5 }
|
|
|
|
aprisaXETx28VHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx28VHiAlarmStatus,
|
|
aprisaXETx28VHiAlarmSeverity,
|
|
aprisaXETx28VHiAlarmEnabled,
|
|
aprisaXETx28VHiAlarmThreshold,
|
|
aprisaXETx28VHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 28V voltage too high alarm group."
|
|
::= { aprisaXEGroups 146 }
|
|
|
|
|
|
aprisaXETx28VLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 20 }
|
|
|
|
aprisaXETx28VLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the transmitter 28V voltage too low alarm."
|
|
::= { aprisaXETx28VLoAlarm 1 }
|
|
|
|
aprisaXETx28VLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the transmitter 28V voltage too low alarm."
|
|
::= { aprisaXETx28VLoAlarm 2 }
|
|
|
|
aprisaXETx28VLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the transmitter 28V voltage too low alarm is enabled."
|
|
::= { aprisaXETx28VLoAlarm 3 }
|
|
|
|
aprisaXETx28VLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 28V voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETx28VLoAlarm 4 }
|
|
|
|
aprisaXETx28VLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the transmitter 28V voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETx28VLoAlarm 5 }
|
|
|
|
aprisaXETx28VLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETx28VLoAlarmStatus,
|
|
aprisaXETx28VLoAlarmSeverity,
|
|
aprisaXETx28VLoAlarmEnabled,
|
|
aprisaXETx28VLoAlarmThreshold,
|
|
aprisaXETx28VLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE transmitter 28V voltage too low alarm group."
|
|
::= { aprisaXEGroups 151 }
|
|
|
|
|
|
--
|
|
-- Transmitter synthesiser out of lock alarm
|
|
--
|
|
|
|
aprisaXETxSynthOutOfLockAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 21 }
|
|
|
|
aprisaXETxSynthOutOfLockAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the TX synth out of lock alarm."
|
|
::= { aprisaXETxSynthOutOfLockAlarm 1 }
|
|
|
|
aprisaXETxSynthOutOfLockAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the TX synth out of lock alarm."
|
|
::= { aprisaXETxSynthOutOfLockAlarm 2 }
|
|
|
|
aprisaXETxSynthOutOfLockAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the TX synth out of lock alarm is enabled."
|
|
::= { aprisaXETxSynthOutOfLockAlarm 3 }
|
|
|
|
aprisaXETxSynthOutOfLockAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxSynthOutOfLockAlarmStatus,
|
|
aprisaXETxSynthOutOfLockAlarmSeverity,
|
|
aprisaXETxSynthOutOfLockAlarmEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE TX Synth out of lock alarm group."
|
|
::= { aprisaXEGroups 153 }
|
|
|
|
|
|
--
|
|
-- Return Loss Too High Alarm
|
|
--
|
|
-- The threshold values vary according to the currently selected modulation.
|
|
--
|
|
|
|
aprisaXEReturnLossHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 22 }
|
|
|
|
aprisaXEReturnLossHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the return loss out of limits alarm."
|
|
::= { aprisaXEReturnLossHiAlarm 1 }
|
|
|
|
aprisaXEReturnLossHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the return loss out of limits alarm."
|
|
::= { aprisaXEReturnLossHiAlarm 2 }
|
|
|
|
aprisaXEReturnLossHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the return loss out of limits alarm is enabled."
|
|
::= { aprisaXEReturnLossHiAlarm 3 }
|
|
|
|
aprisaXEReturnLossHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the return loss alarm will be set."
|
|
::= { aprisaXEReturnLossHiAlarm 4 }
|
|
|
|
aprisaXEReturnLossHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the return loss alarm will be cleared."
|
|
::= { aprisaXEReturnLossHiAlarm 5 }
|
|
|
|
aprisaXEReturnLossHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEReturnLossHiAlarmStatus,
|
|
aprisaXEReturnLossHiAlarmSeverity,
|
|
aprisaXEReturnLossHiAlarmEnabled,
|
|
aprisaXEReturnLossHiAlarmThreshold,
|
|
aprisaXEReturnLossHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE reverse power too high alarm group."
|
|
::= { aprisaXEGroups 152 }
|
|
|
|
-- ***************************************************************************
|
|
-- End of Transmitter alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- The Receiver alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEReceiverAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 6 }
|
|
|
|
|
|
-- Rx Synthesizer out of lock
|
|
|
|
aprisaXERxSynthOutOfLockAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 1 }
|
|
|
|
aprisaXERxSynthOutOfLockAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the Synth out of lock alarm."
|
|
::= { aprisaXERxSynthOutOfLockAlarm 1 }
|
|
|
|
aprisaXERxSynthOutOfLockAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the Synth out of lock alarm."
|
|
::= { aprisaXERxSynthOutOfLockAlarm 2 }
|
|
|
|
aprisaXERxSynthOutOfLockAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the Synth out of lock alarm is enabled."
|
|
::= { aprisaXERxSynthOutOfLockAlarm 3 }
|
|
|
|
aprisaXERxSynthOutOfLockAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxSynthOutOfLockAlarmStatus,
|
|
aprisaXERxSynthOutOfLockAlarmSeverity,
|
|
aprisaXERxSynthOutOfLockAlarmEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE Synth out of lock alarm group."
|
|
::= { aprisaXEGroups 161 }
|
|
|
|
|
|
--
|
|
-- 12 V alarm
|
|
--
|
|
aprisaXERx12VAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 3 }
|
|
|
|
aprisaXERx12VAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the 12V supply alarm."
|
|
::= { aprisaXERx12VAlarm 1 }
|
|
|
|
aprisaXERx12VAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the 12V supply aprisaXERxVtuneLoAlarmalarm."
|
|
::= { aprisaXERx12VAlarm 2 }
|
|
|
|
aprisaXERx12VAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the 12V supply alarm is enabled."
|
|
::= { aprisaXERx12VAlarm 3 }
|
|
|
|
aprisaXERx12VAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx12VAlarmStatus,
|
|
aprisaXERx12VAlarmSeverity,
|
|
aprisaXERx12VAlarmEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE 12V supply alarm group."
|
|
::= { aprisaXEGroups 166 }
|
|
|
|
|
|
--
|
|
-- 3.3V high alarm
|
|
--
|
|
|
|
aprisaXERx3V3HiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 4 }
|
|
|
|
aprisaXERx3V3HiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 3.3V supply high alarm."
|
|
::= { aprisaXERx3V3HiAlarm 1 }
|
|
|
|
aprisaXERx3V3HiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 3.3V supply high alarm."
|
|
::= { aprisaXERx3V3HiAlarm 2 }
|
|
|
|
aprisaXERx3V3HiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 3.3V supply high alarm is enabled."
|
|
::= { aprisaXERx3V3HiAlarm 3 }
|
|
|
|
aprisaXERx3V3HiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 3.3V supply high
|
|
alarm will be set."
|
|
::= { aprisaXERx3V3HiAlarm 4 }
|
|
|
|
aprisaXERx3V3HiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 3.3V supply high
|
|
will be cleared."
|
|
::= { aprisaXERx3V3HiAlarm 5 }
|
|
|
|
aprisaXERx3V3HiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx3V3HiAlarmStatus,
|
|
aprisaXERx3V3HiAlarmSeverity,
|
|
aprisaXERx3V3HiAlarmEnabled,
|
|
aprisaXERx3V3HiAlarmThreshold,
|
|
aprisaXERx3V3HiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 3.3V supply high alarm group."
|
|
::= { aprisaXEGroups 171 }
|
|
|
|
|
|
--
|
|
--3.3V low alarm
|
|
--
|
|
|
|
aprisaXERx3V3LoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 5 }
|
|
|
|
aprisaXERx3V3LoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 3.3V supply low alarm."
|
|
::= { aprisaXERx3V3LoAlarm 1 }
|
|
|
|
aprisaXERx3V3LoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 3.3V supply low alarm."
|
|
::= { aprisaXERx3V3LoAlarm 2 }
|
|
|
|
aprisaXERx3V3LoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 3.3V supply low alarm is enabled."
|
|
::= { aprisaXERx3V3LoAlarm 3 }
|
|
|
|
aprisaXERx3V3LoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 3.3V supply low
|
|
alarm will be set."
|
|
::= { aprisaXERx3V3LoAlarm 4 }
|
|
|
|
aprisaXERx3V3LoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 3.3V supply low
|
|
will be cleared."
|
|
::= { aprisaXERx3V3LoAlarm 5 }
|
|
|
|
aprisaXERx3V3LoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx3V3LoAlarmStatus,
|
|
aprisaXERx3V3LoAlarmSeverity,
|
|
aprisaXERx3V3LoAlarmEnabled,
|
|
aprisaXERx3V3LoAlarmThreshold,
|
|
aprisaXERx3V3LoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 3.3V supply low alarm group."
|
|
::= { aprisaXEGroups 176 }
|
|
|
|
|
|
--
|
|
-- 5V high alarm
|
|
--
|
|
|
|
aprisaXERx5VHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 6 }
|
|
|
|
aprisaXERx5VHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 5V supply High alarm."
|
|
::= { aprisaXERx5VHiAlarm 1 }
|
|
|
|
aprisaXERx5VHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 5V supply High alarm."
|
|
::= { aprisaXERx5VHiAlarm 2 }
|
|
|
|
aprisaXERx5VHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 5V supply High alarm is enabled."
|
|
::= { aprisaXERx5VHiAlarm 3 }
|
|
|
|
aprisaXERx5VHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 5V supply High
|
|
alarm will be set."
|
|
::= { aprisaXERx5VHiAlarm 4 }
|
|
|
|
aprisaXERx5VHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 5V supply High
|
|
will be cleared."
|
|
::= { aprisaXERx5VHiAlarm 5 }
|
|
|
|
aprisaXERx5VHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx5VHiAlarmStatus,
|
|
aprisaXERx5VHiAlarmSeverity,
|
|
aprisaXERx5VHiAlarmEnabled,
|
|
aprisaXERx5VHiAlarmThreshold,
|
|
aprisaXERx5VHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 5V supply High alarm group."
|
|
::= { aprisaXEGroups 181 }
|
|
|
|
|
|
--
|
|
--5V low alarm
|
|
--
|
|
|
|
aprisaXERx5VLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 7 }
|
|
|
|
aprisaXERx5VLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 5V supply low alarm."
|
|
::= { aprisaXERx5VLoAlarm 1 }
|
|
|
|
aprisaXERx5VLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 5V supply low alarm."
|
|
::= { aprisaXERx5VLoAlarm 2 }
|
|
|
|
aprisaXERx5VLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 5V supply low alarm is enabled."
|
|
::= { aprisaXERx5VLoAlarm 3 }
|
|
|
|
aprisaXERx5VLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 5V supply low
|
|
alarm will be set."
|
|
::= { aprisaXERx5VLoAlarm 4 }
|
|
|
|
aprisaXERx5VLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 5V supply low
|
|
will be cleared."
|
|
::= { aprisaXERx5VLoAlarm 5 }
|
|
|
|
aprisaXERx5VLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx5VLoAlarmStatus,
|
|
aprisaXERx5VLoAlarmSeverity,
|
|
aprisaXERx5VLoAlarmEnabled,
|
|
aprisaXERx5VLoAlarmThreshold,
|
|
aprisaXERx5VLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 5V supply low alarm group."
|
|
::= { aprisaXEGroups 186 }
|
|
|
|
|
|
--
|
|
-- 9V high alarm
|
|
--
|
|
|
|
aprisaXERx9VHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 8 }
|
|
|
|
aprisaXERx9VHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 9V supply High alarm."
|
|
::= { aprisaXERx9VHiAlarm 1 }
|
|
|
|
aprisaXERx9VHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 9V supply High alarm."
|
|
::= { aprisaXERx9VHiAlarm 2 }
|
|
|
|
aprisaXERx9VHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 9V supply High alarm is enabled."
|
|
::= { aprisaXERx9VHiAlarm 3 }
|
|
|
|
aprisaXERx9VHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 9V supply High
|
|
alarm will be set."
|
|
::= { aprisaXERx9VHiAlarm 4 }
|
|
|
|
aprisaXERx9VHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 9V supply High
|
|
will be cleared."
|
|
::= { aprisaXERx9VHiAlarm 5 }
|
|
|
|
aprisaXERx9VHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx9VHiAlarmStatus,
|
|
aprisaXERx9VHiAlarmSeverity,
|
|
aprisaXERx9VHiAlarmEnabled,
|
|
aprisaXERx9VHiAlarmThreshold,
|
|
aprisaXERx9VHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 9V supply High alarm group."
|
|
::= { aprisaXEGroups 191 }
|
|
|
|
|
|
--
|
|
-- 9V low alarm
|
|
--
|
|
|
|
aprisaXERx9VLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 9 }
|
|
|
|
aprisaXERx9VLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the 9V supply low alarm."
|
|
::= { aprisaXERx9VLoAlarm 1 }
|
|
|
|
aprisaXERx9VLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the 9V supply low alarm."
|
|
::= { aprisaXERx9VLoAlarm 2 }
|
|
|
|
aprisaXERx9VLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the 9V supply low alarm is enabled."
|
|
::= { aprisaXERx9VLoAlarm 3 }
|
|
|
|
aprisaXERx9VLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 9V supply low
|
|
alarm will be set."
|
|
::= { aprisaXERx9VLoAlarm 4 }
|
|
|
|
aprisaXERx9VLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the 9V supply low
|
|
will be cleared."
|
|
::= { aprisaXERx9VLoAlarm 5 }
|
|
|
|
aprisaXERx9VLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERx9VLoAlarmStatus,
|
|
aprisaXERx9VLoAlarmSeverity,
|
|
aprisaXERx9VLoAlarmEnabled,
|
|
aprisaXERx9VLoAlarmThreshold,
|
|
aprisaXERx9VLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE 9V supply low alarm group."
|
|
::= { aprisaXEGroups 196 }
|
|
|
|
|
|
--
|
|
-- Neg 1V5 high alarm
|
|
--
|
|
|
|
aprisaXERxNeg1V5HiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 10 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the Neg 1.5V supply High alarm."
|
|
::= { aprisaXERxNeg1V5HiAlarm 1 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the Neg 1.5V supply High alarm."
|
|
::= { aprisaXERxNeg1V5HiAlarm 2 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the Neg 1.5V supply High alarm is enabled."
|
|
::= { aprisaXERxNeg1V5HiAlarm 3 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Neg 1.5V supply High
|
|
alarm will be set."
|
|
::= { aprisaXERxNeg1V5HiAlarm 4 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Neg 1.5V supply High
|
|
will be cleared."
|
|
::= { aprisaXERxNeg1V5HiAlarm 5 }
|
|
|
|
aprisaXERxNeg1V5HiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxNeg1V5HiAlarmStatus,
|
|
aprisaXERxNeg1V5HiAlarmSeverity,
|
|
aprisaXERxNeg1V5HiAlarmEnabled,
|
|
aprisaXERxNeg1V5HiAlarmThreshold,
|
|
aprisaXERxNeg1V5HiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE Neg 1.5V supply High alarm group."
|
|
::= { aprisaXEGroups 201 }
|
|
|
|
|
|
--
|
|
-- Neg 1V5 low alarm
|
|
--
|
|
|
|
aprisaXERxNeg1V5LoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 11 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the Neg 1.5V supply low alarm."
|
|
::= { aprisaXERxNeg1V5LoAlarm 1 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the Neg 1.5V supply low alarm."
|
|
::= { aprisaXERxNeg1V5LoAlarm 2 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the Neg 1.5V supply low alarm is enabled."
|
|
::= { aprisaXERxNeg1V5LoAlarm 3 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Neg 1.5V supply low
|
|
alarm will be set."
|
|
::= { aprisaXERxNeg1V5LoAlarm 4 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Neg 1.5V supply low
|
|
will be cleared."
|
|
::= { aprisaXERxNeg1V5LoAlarm 5 }
|
|
|
|
aprisaXERxNeg1V5LoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxNeg1V5LoAlarmStatus,
|
|
aprisaXERxNeg1V5LoAlarmSeverity,
|
|
aprisaXERxNeg1V5LoAlarmEnabled,
|
|
aprisaXERxNeg1V5LoAlarmThreshold,
|
|
aprisaXERxNeg1V5LoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE Neg 1.5V supply low alarm group."
|
|
::= { aprisaXEGroups 206 }
|
|
|
|
|
|
--
|
|
-- AGC high alarm
|
|
--
|
|
|
|
aprisaXERxAgcHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 12 }
|
|
|
|
aprisaXERxAgcHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the AGC high alarm."
|
|
::= { aprisaXERxAgcHiAlarm 1 }
|
|
|
|
aprisaXERxAgcHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the AGC high alarm."
|
|
::= { aprisaXERxAgcHiAlarm 2 }
|
|
|
|
aprisaXERxAgcHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the AGC high alarm is enabled."
|
|
::= { aprisaXERxAgcHiAlarm 3 }
|
|
|
|
aprisaXERxAgcHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the AGC high
|
|
alarm will be set."
|
|
::= { aprisaXERxAgcHiAlarm 4 }
|
|
|
|
aprisaXERxAgcHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the AGC high
|
|
will be cleared."
|
|
::= { aprisaXERxAgcHiAlarm 5 }
|
|
|
|
aprisaXERxAgcHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxAgcHiAlarmStatus,
|
|
aprisaXERxAgcHiAlarmSeverity,
|
|
aprisaXERxAgcHiAlarmEnabled,
|
|
aprisaXERxAgcHiAlarmThreshold,
|
|
aprisaXERxAgcHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE AGC high alarm group."
|
|
::= { aprisaXEGroups 211 }
|
|
|
|
|
|
--
|
|
--AGC low alarm
|
|
--
|
|
|
|
aprisaXERxAgcLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 13 }
|
|
|
|
aprisaXERxAgcLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the AGC low alarm."
|
|
::= { aprisaXERxAgcLoAlarm 1 }
|
|
|
|
aprisaXERxAgcLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the AGC low alarm."
|
|
::= { aprisaXERxAgcLoAlarm 2 }
|
|
|
|
aprisaXERxAgcLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the AGC low alarm is enabled."
|
|
::= { aprisaXERxAgcLoAlarm 3 }
|
|
|
|
aprisaXERxAgcLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the AGC low
|
|
alarm will be set."
|
|
::= { aprisaXERxAgcLoAlarm 4 }
|
|
|
|
aprisaXERxAgcLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the AGC low
|
|
will be cleared."
|
|
::= { aprisaXERxAgcLoAlarm 5 }
|
|
|
|
aprisaXERxAgcLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxAgcLoAlarmStatus,
|
|
aprisaXERxAgcLoAlarmSeverity,
|
|
aprisaXERxAgcLoAlarmEnabled,
|
|
aprisaXERxAgcLoAlarmThreshold,
|
|
aprisaXERxAgcLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE AGC low alarm group."
|
|
::= { aprisaXEGroups 216 }
|
|
|
|
|
|
--
|
|
-- RSSI High alarm
|
|
--
|
|
|
|
aprisaXERxRssiHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 14 }
|
|
|
|
aprisaXERxRssiHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the RSSI High alarm."
|
|
::= { aprisaXERxRssiHiAlarm 1 }
|
|
|
|
aprisaXERxRssiHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the RSSI High alarm."
|
|
::= { aprisaXERxRssiHiAlarm 2 }
|
|
|
|
aprisaXERxRssiHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the RSSI High alarm is enabled."
|
|
::= { aprisaXERxRssiHiAlarm 3 }
|
|
|
|
aprisaXERxRssiHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the RSSI High
|
|
alarm will be set."
|
|
::= { aprisaXERxRssiHiAlarm 4 }
|
|
|
|
aprisaXERxRssiHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the RSSI High
|
|
will be cleared."
|
|
::= { aprisaXERxRssiHiAlarm 5 }
|
|
|
|
aprisaXERxRssiHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxRssiHiAlarmStatus,
|
|
aprisaXERxRssiHiAlarmSeverity,
|
|
aprisaXERxRssiHiAlarmEnabled,
|
|
aprisaXERxRssiHiAlarmThreshold,
|
|
aprisaXERxRssiHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE RSSI High alarm group."
|
|
::= { aprisaXEGroups 221 }
|
|
|
|
|
|
--
|
|
-- RSSI low alarms
|
|
--
|
|
|
|
aprisaXERxRssiLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 15 }
|
|
|
|
aprisaXERxRssiLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the RSSI low alarm."
|
|
::= { aprisaXERxRssiLoAlarm 1 }
|
|
|
|
aprisaXERxRssiLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the RSSI low alarm."
|
|
::= { aprisaXERxRssiLoAlarm 2 }
|
|
|
|
aprisaXERxRssiLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the RSSI low alarm is enabled."
|
|
::= { aprisaXERxRssiLoAlarm 3 }
|
|
|
|
aprisaXERxRssiLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the RSSI low
|
|
alarm will be set."
|
|
::= { aprisaXERxRssiLoAlarm 4 }
|
|
|
|
aprisaXERxRssiLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the RSSI low
|
|
will be cleared."
|
|
::= { aprisaXERxRssiLoAlarm 5 }
|
|
|
|
aprisaXERxRssiLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxRssiLoAlarmStatus,
|
|
aprisaXERxRssiLoAlarmSeverity,
|
|
aprisaXERxRssiLoAlarmEnabled,
|
|
aprisaXERxRssiLoAlarmThreshold,
|
|
aprisaXERxRssiLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE RSSI low alarm group."
|
|
::= { aprisaXEGroups 226 }
|
|
|
|
|
|
--
|
|
-- VTune High Alarm
|
|
--
|
|
|
|
aprisaXERxVtuneHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 16 }
|
|
|
|
aprisaXERxVtuneHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the Vtune High alarm."
|
|
::= { aprisaXERxVtuneHiAlarm 1 }
|
|
|
|
aprisaXERxVtuneHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the Vtune High alarm."
|
|
::= { aprisaXERxVtuneHiAlarm 2 }
|
|
|
|
aprisaXERxVtuneHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the Vtune High alarm is enabled."
|
|
::= { aprisaXERxVtuneHiAlarm 3 }
|
|
|
|
aprisaXERxVtuneHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Vtune High
|
|
alarm will be set."
|
|
::= { aprisaXERxVtuneHiAlarm 4 }
|
|
|
|
aprisaXERxVtuneHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Vtune High
|
|
will be cleared."
|
|
::= { aprisaXERxVtuneHiAlarm 5 }
|
|
|
|
aprisaXERxVtuneHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxVtuneHiAlarmStatus,
|
|
aprisaXERxVtuneHiAlarmSeverity,
|
|
aprisaXERxVtuneHiAlarmEnabled,
|
|
aprisaXERxVtuneHiAlarmThreshold,
|
|
aprisaXERxVtuneHiAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE Vtune High alarm group."
|
|
::= { aprisaXEGroups 231 }
|
|
|
|
|
|
--
|
|
--Vtune low alarm
|
|
--
|
|
|
|
aprisaXERxVtuneLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 17 }
|
|
|
|
aprisaXERxVtuneLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The status of the Vtune low alarm."
|
|
::= { aprisaXERxVtuneLoAlarm 1 }
|
|
|
|
aprisaXERxVtuneLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "The severity of the Vtune low alarm."
|
|
::= { aprisaXERxVtuneLoAlarm 2 }
|
|
|
|
aprisaXERxVtuneLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates whether the Vtune low alarm is enabled."
|
|
::= { aprisaXERxVtuneLoAlarm 3 }
|
|
|
|
aprisaXERxVtuneLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Vtune low
|
|
alarm will be set."
|
|
::= { aprisaXERxVtuneLoAlarm 4 }
|
|
|
|
aprisaXERxVtuneLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION "Indicates the level at which the Vtune low
|
|
will be cleared."
|
|
::= { aprisaXERxVtuneLoAlarm 5 }
|
|
|
|
aprisaXERxVtuneLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxVtuneLoAlarmStatus,
|
|
aprisaXERxVtuneLoAlarmSeverity,
|
|
aprisaXERxVtuneLoAlarmEnabled,
|
|
aprisaXERxVtuneLoAlarmThreshold,
|
|
aprisaXERxVtuneLoAlarmClearThreshold
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION "The AprisaXE Vtune low alarm group."
|
|
::= { aprisaXEGroups 236 }
|
|
|
|
|
|
--
|
|
-- EE Alarm
|
|
--
|
|
|
|
aprisaXERxEEAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 18 }
|
|
|
|
aprisaXERxEEAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the EEPROM alarm."
|
|
::= { aprisaXERxEEAlarm 1 }
|
|
|
|
aprisaXERxEEAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the EEPROM alarm."
|
|
::= { aprisaXERxEEAlarm 2 }
|
|
|
|
aprisaXERxEEAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the EEPROM alarm is enabled."
|
|
::= { aprisaXERxEEAlarm 3 }
|
|
|
|
aprisaXERxEEAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxEEAlarmStatus,
|
|
aprisaXERxEEAlarmSeverity,
|
|
aprisaXERxEEAlarmEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE EEPROM alarm group."
|
|
::= { aprisaXEGroups 241 }
|
|
|
|
-- ***************************************************************************
|
|
-- End of Receiver alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- The Generic Transmitter Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXETxADCChZeroHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 23 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXETxADCChZeroHiAlarm 1 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXETxADCChZeroHiAlarm 2 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXETxADCChZeroHiAlarm 3 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Zero voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChZeroHiAlarm 4 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Zero voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChZeroHiAlarm 5 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Zero voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChZeroHiAlarm 6 }
|
|
|
|
aprisaXETxADCChZeroHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChZeroHiAlarmName,
|
|
aprisaXETxADCChZeroHiAlarmStatus,
|
|
aprisaXETxADCChZeroHiAlarmSeverity,
|
|
aprisaXETxADCChZeroHiAlarmEnabled,
|
|
aprisaXETxADCChZeroHiAlarmThreshold,
|
|
aprisaXETxADCChZeroHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Zero voltage too high alarm group."
|
|
::= { aprisaXEGroups 250 }
|
|
|
|
|
|
aprisaXETxADCChZeroLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 24 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXETxADCChZeroLoAlarm 1 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXETxADCChZeroLoAlarm 2 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXETxADCChZeroLoAlarm 3 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Zero voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChZeroLoAlarm 4 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChZeroLoAlarm 5 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Zero voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChZeroLoAlarm 6 }
|
|
|
|
aprisaXETxADCChZeroLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChZeroLoAlarmName,
|
|
aprisaXETxADCChZeroLoAlarmStatus,
|
|
aprisaXETxADCChZeroLoAlarmSeverity,
|
|
aprisaXETxADCChZeroLoAlarmEnabled,
|
|
aprisaXETxADCChZeroLoAlarmThreshold,
|
|
aprisaXETxADCChZeroLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Zero voltage too High alarm group."
|
|
::= { aprisaXEGroups 251 }
|
|
|
|
|
|
aprisaXETxADCChOneHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 25 }
|
|
|
|
aprisaXETxADCChOneHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch One voltage too high alarm."
|
|
::= { aprisaXETxADCChOneHiAlarm 1 }
|
|
|
|
aprisaXETxADCChOneHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch One voltage too high alarm."
|
|
::= { aprisaXETxADCChOneHiAlarm 2 }
|
|
|
|
aprisaXETxADCChOneHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch One voltage too high alarm."
|
|
::= { aprisaXETxADCChOneHiAlarm 3 }
|
|
|
|
aprisaXETxADCChOneHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch One voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChOneHiAlarm 4 }
|
|
|
|
aprisaXETxADCChOneHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch One voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChOneHiAlarm 5 }
|
|
|
|
aprisaXETxADCChOneHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch One voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChOneHiAlarm 6 }
|
|
|
|
aprisaXETxADCChOneHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChOneHiAlarmName,
|
|
aprisaXETxADCChOneHiAlarmStatus,
|
|
aprisaXETxADCChOneHiAlarmSeverity,
|
|
aprisaXETxADCChOneHiAlarmEnabled,
|
|
aprisaXETxADCChOneHiAlarmThreshold,
|
|
aprisaXETxADCChOneHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch One voltage too high alarm group."
|
|
::= { aprisaXEGroups 252 }
|
|
|
|
|
|
aprisaXETxADCChOneLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 26 }
|
|
|
|
aprisaXETxADCChOneLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch One voltage too low alarm."
|
|
::= { aprisaXETxADCChOneLoAlarm 1 }
|
|
|
|
aprisaXETxADCChOneLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch One voltage too low alarm."
|
|
::= { aprisaXETxADCChOneLoAlarm 2 }
|
|
|
|
aprisaXETxADCChOneLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch One voltage too low alarm."
|
|
::= { aprisaXETxADCChOneLoAlarm 3 }
|
|
|
|
aprisaXETxADCChOneLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch One voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChOneLoAlarm 4 }
|
|
|
|
aprisaXETxADCChOneLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch One voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChOneLoAlarm 5 }
|
|
|
|
aprisaXETxADCChOneLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch One voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChOneLoAlarm 6 }
|
|
|
|
aprisaXETxADCChOneLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChOneLoAlarmName,
|
|
aprisaXETxADCChOneLoAlarmStatus,
|
|
aprisaXETxADCChOneLoAlarmSeverity,
|
|
aprisaXETxADCChOneLoAlarmEnabled,
|
|
aprisaXETxADCChOneLoAlarmThreshold,
|
|
aprisaXETxADCChOneLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch One voltage too High alarm group."
|
|
::= { aprisaXEGroups 253 }
|
|
|
|
|
|
aprisaXETxADCChTwoHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 27 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXETxADCChTwoHiAlarm 1 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXETxADCChTwoHiAlarm 2 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXETxADCChTwoHiAlarm 3 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Two voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChTwoHiAlarm 4 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Two voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChTwoHiAlarm 5 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Two voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChTwoHiAlarm 6 }
|
|
|
|
aprisaXETxADCChTwoHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChTwoHiAlarmName,
|
|
aprisaXETxADCChTwoHiAlarmStatus,
|
|
aprisaXETxADCChTwoHiAlarmSeverity,
|
|
aprisaXETxADCChTwoHiAlarmEnabled,
|
|
aprisaXETxADCChTwoHiAlarmThreshold,
|
|
aprisaXETxADCChTwoHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Two voltage too high alarm group."
|
|
::= { aprisaXEGroups 254 }
|
|
|
|
|
|
aprisaXETxADCChTwoLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 28 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXETxADCChTwoLoAlarm 1 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXETxADCChTwoLoAlarm 2 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXETxADCChTwoLoAlarm 3 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Two voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChTwoLoAlarm 4 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Two voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChTwoLoAlarm 5 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Two voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChTwoLoAlarm 6 }
|
|
|
|
aprisaXETxADCChTwoLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChTwoLoAlarmName,
|
|
aprisaXETxADCChTwoLoAlarmStatus,
|
|
aprisaXETxADCChTwoLoAlarmSeverity,
|
|
aprisaXETxADCChTwoLoAlarmEnabled,
|
|
aprisaXETxADCChTwoLoAlarmThreshold,
|
|
aprisaXETxADCChTwoLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Two voltage too High alarm group."
|
|
::= { aprisaXEGroups 255 }
|
|
|
|
|
|
aprisaXETxADCChThreeHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 29 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXETxADCChThreeHiAlarm 1 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXETxADCChThreeHiAlarm 2 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXETxADCChThreeHiAlarm 3 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Three voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChThreeHiAlarm 4 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Three voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChThreeHiAlarm 5 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Three voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChThreeHiAlarm 6 }
|
|
|
|
aprisaXETxADCChThreeHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChThreeHiAlarmName,
|
|
aprisaXETxADCChThreeHiAlarmStatus,
|
|
aprisaXETxADCChThreeHiAlarmSeverity,
|
|
aprisaXETxADCChThreeHiAlarmEnabled,
|
|
aprisaXETxADCChThreeHiAlarmThreshold,
|
|
aprisaXETxADCChThreeHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Three voltage too high alarm group."
|
|
::= { aprisaXEGroups 256 }
|
|
|
|
|
|
aprisaXETxADCChThreeLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 30 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXETxADCChThreeLoAlarm 1 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXETxADCChThreeLoAlarm 2 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXETxADCChThreeLoAlarm 3 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Three voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChThreeLoAlarm 4 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Three voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChThreeLoAlarm 5 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Three voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChThreeLoAlarm 6 }
|
|
|
|
aprisaXETxADCChThreeLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChThreeLoAlarmName,
|
|
aprisaXETxADCChThreeLoAlarmStatus,
|
|
aprisaXETxADCChThreeLoAlarmSeverity,
|
|
aprisaXETxADCChThreeLoAlarmEnabled,
|
|
aprisaXETxADCChThreeLoAlarmThreshold,
|
|
aprisaXETxADCChThreeLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Three voltage too High alarm group."
|
|
::= { aprisaXEGroups 257 }
|
|
|
|
|
|
aprisaXETxADCChFourHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 31 }
|
|
|
|
aprisaXETxADCChFourHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXETxADCChFourHiAlarm 1 }
|
|
|
|
aprisaXETxADCChFourHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXETxADCChFourHiAlarm 2 }
|
|
|
|
aprisaXETxADCChFourHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXETxADCChFourHiAlarm 3 }
|
|
|
|
aprisaXETxADCChFourHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Four voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChFourHiAlarm 4 }
|
|
|
|
aprisaXETxADCChFourHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Four voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChFourHiAlarm 5 }
|
|
|
|
aprisaXETxADCChFourHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Four voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChFourHiAlarm 6 }
|
|
|
|
aprisaXETxADCChFourHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChFourHiAlarmName,
|
|
aprisaXETxADCChFourHiAlarmStatus,
|
|
aprisaXETxADCChFourHiAlarmSeverity,
|
|
aprisaXETxADCChFourHiAlarmEnabled,
|
|
aprisaXETxADCChFourHiAlarmThreshold,
|
|
aprisaXETxADCChFourHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Four voltage too high alarm group."
|
|
::= { aprisaXEGroups 258 }
|
|
|
|
|
|
aprisaXETxADCChFourLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 32 }
|
|
|
|
aprisaXETxADCChFourLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXETxADCChFourLoAlarm 1 }
|
|
|
|
aprisaXETxADCChFourLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXETxADCChFourLoAlarm 2 }
|
|
|
|
aprisaXETxADCChFourLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXETxADCChFourLoAlarm 3 }
|
|
|
|
aprisaXETxADCChFourLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Four voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChFourLoAlarm 4 }
|
|
|
|
aprisaXETxADCChFourLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Four voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChFourLoAlarm 5 }
|
|
|
|
aprisaXETxADCChFourLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Four voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChFourLoAlarm 6 }
|
|
|
|
aprisaXETxADCChFourLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChFourLoAlarmName,
|
|
aprisaXETxADCChFourLoAlarmStatus,
|
|
aprisaXETxADCChFourLoAlarmSeverity,
|
|
aprisaXETxADCChFourLoAlarmEnabled,
|
|
aprisaXETxADCChFourLoAlarmThreshold,
|
|
aprisaXETxADCChFourLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Four voltage too High alarm group."
|
|
::= { aprisaXEGroups 259 }
|
|
|
|
|
|
aprisaXETxADCChFiveHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 33 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXETxADCChFiveHiAlarm 1 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXETxADCChFiveHiAlarm 2 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXETxADCChFiveHiAlarm 3 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Five voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChFiveHiAlarm 4 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Five voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChFiveHiAlarm 5 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Five voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChFiveHiAlarm 6 }
|
|
|
|
aprisaXETxADCChFiveHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChFiveHiAlarmName,
|
|
aprisaXETxADCChFiveHiAlarmStatus,
|
|
aprisaXETxADCChFiveHiAlarmSeverity,
|
|
aprisaXETxADCChFiveHiAlarmEnabled,
|
|
aprisaXETxADCChFiveHiAlarmThreshold,
|
|
aprisaXETxADCChFiveHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Five voltage too high alarm group."
|
|
::= { aprisaXEGroups 260 }
|
|
|
|
|
|
aprisaXETxADCChFiveLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 34 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXETxADCChFiveLoAlarm 1 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXETxADCChFiveLoAlarm 2 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXETxADCChFiveLoAlarm 3 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Five voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChFiveLoAlarm 4 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Five voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChFiveLoAlarm 5 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Five voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChFiveLoAlarm 6 }
|
|
|
|
aprisaXETxADCChFiveLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChFiveLoAlarmName,
|
|
aprisaXETxADCChFiveLoAlarmStatus,
|
|
aprisaXETxADCChFiveLoAlarmSeverity,
|
|
aprisaXETxADCChFiveLoAlarmEnabled,
|
|
aprisaXETxADCChFiveLoAlarmThreshold,
|
|
aprisaXETxADCChFiveLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Five voltage too High alarm group."
|
|
::= { aprisaXEGroups 261 }
|
|
|
|
|
|
aprisaXETxADCChSixHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 35 }
|
|
|
|
aprisaXETxADCChSixHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXETxADCChSixHiAlarm 1 }
|
|
|
|
aprisaXETxADCChSixHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXETxADCChSixHiAlarm 2 }
|
|
|
|
aprisaXETxADCChSixHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXETxADCChSixHiAlarm 3 }
|
|
|
|
aprisaXETxADCChSixHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Six voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChSixHiAlarm 4 }
|
|
|
|
aprisaXETxADCChSixHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Six voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChSixHiAlarm 5 }
|
|
|
|
aprisaXETxADCChSixHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Six voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChSixHiAlarm 6 }
|
|
|
|
aprisaXETxADCChSixHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChSixHiAlarmName,
|
|
aprisaXETxADCChSixHiAlarmStatus,
|
|
aprisaXETxADCChSixHiAlarmSeverity,
|
|
aprisaXETxADCChSixHiAlarmEnabled,
|
|
aprisaXETxADCChSixHiAlarmThreshold,
|
|
aprisaXETxADCChSixHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Six voltage too high alarm group."
|
|
::= { aprisaXEGroups 262 }
|
|
|
|
|
|
aprisaXETxADCChSixLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 36 }
|
|
|
|
aprisaXETxADCChSixLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXETxADCChSixLoAlarm 1 }
|
|
|
|
aprisaXETxADCChSixLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXETxADCChSixLoAlarm 2 }
|
|
|
|
aprisaXETxADCChSixLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXETxADCChSixLoAlarm 3 }
|
|
|
|
aprisaXETxADCChSixLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Six voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChSixLoAlarm 4 }
|
|
|
|
aprisaXETxADCChSixLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Six voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChSixLoAlarm 5 }
|
|
|
|
aprisaXETxADCChSixLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Six voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChSixLoAlarm 6 }
|
|
|
|
aprisaXETxADCChSixLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChSixLoAlarmName,
|
|
aprisaXETxADCChSixLoAlarmStatus,
|
|
aprisaXETxADCChSixLoAlarmSeverity,
|
|
aprisaXETxADCChSixLoAlarmEnabled,
|
|
aprisaXETxADCChSixLoAlarmThreshold,
|
|
aprisaXETxADCChSixLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Six voltage too High alarm group."
|
|
::= { aprisaXEGroups 263 }
|
|
|
|
|
|
aprisaXETxADCChSevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 37 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXETxADCChSevenHiAlarm 1 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXETxADCChSevenHiAlarm 2 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXETxADCChSevenHiAlarm 3 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Seven voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChSevenHiAlarm 4 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Seven voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChSevenHiAlarm 5 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Seven voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChSevenHiAlarm 6 }
|
|
|
|
aprisaXETxADCChSevenHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChSevenHiAlarmName,
|
|
aprisaXETxADCChSevenHiAlarmStatus,
|
|
aprisaXETxADCChSevenHiAlarmSeverity,
|
|
aprisaXETxADCChSevenHiAlarmEnabled,
|
|
aprisaXETxADCChSevenHiAlarmThreshold,
|
|
aprisaXETxADCChSevenHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Seven voltage too high alarm group."
|
|
::= { aprisaXEGroups 264 }
|
|
|
|
|
|
aprisaXETxADCChSevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 38 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXETxADCChSevenLoAlarm 1 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXETxADCChSevenLoAlarm 2 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXETxADCChSevenLoAlarm 3 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Seven voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChSevenLoAlarm 4 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChSevenLoAlarm 5 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Seven voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChSevenLoAlarm 6 }
|
|
|
|
aprisaXETxADCChSevenLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChSevenLoAlarmName,
|
|
aprisaXETxADCChSevenLoAlarmStatus,
|
|
aprisaXETxADCChSevenLoAlarmSeverity,
|
|
aprisaXETxADCChSevenLoAlarmEnabled,
|
|
aprisaXETxADCChSevenLoAlarmThreshold,
|
|
aprisaXETxADCChSevenLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Seven voltage too High alarm group."
|
|
::= { aprisaXEGroups 265 }
|
|
|
|
|
|
aprisaXETxADCChEightHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 39 }
|
|
|
|
aprisaXETxADCChEightHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXETxADCChEightHiAlarm 1 }
|
|
|
|
aprisaXETxADCChEightHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXETxADCChEightHiAlarm 2 }
|
|
|
|
aprisaXETxADCChEightHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXETxADCChEightHiAlarm 3 }
|
|
|
|
aprisaXETxADCChEightHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Eight voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChEightHiAlarm 4 }
|
|
|
|
aprisaXETxADCChEightHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eight voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChEightHiAlarm 5 }
|
|
|
|
aprisaXETxADCChEightHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eight voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChEightHiAlarm 6 }
|
|
|
|
aprisaXETxADCChEightHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChEightHiAlarmName,
|
|
aprisaXETxADCChEightHiAlarmStatus,
|
|
aprisaXETxADCChEightHiAlarmSeverity,
|
|
aprisaXETxADCChEightHiAlarmEnabled,
|
|
aprisaXETxADCChEightHiAlarmThreshold,
|
|
aprisaXETxADCChEightHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Eight voltage too high alarm group."
|
|
::= { aprisaXEGroups 266 }
|
|
|
|
|
|
aprisaXETxADCChEightLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 40 }
|
|
|
|
aprisaXETxADCChEightLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXETxADCChEightLoAlarm 1 }
|
|
|
|
aprisaXETxADCChEightLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXETxADCChEightLoAlarm 2 }
|
|
|
|
aprisaXETxADCChEightLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXETxADCChEightLoAlarm 3 }
|
|
|
|
aprisaXETxADCChEightLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Eight voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChEightLoAlarm 4 }
|
|
|
|
aprisaXETxADCChEightLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChEightLoAlarm 5 }
|
|
|
|
aprisaXETxADCChEightLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eight voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChEightLoAlarm 6 }
|
|
|
|
aprisaXETxADCChEightLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChEightLoAlarmName,
|
|
aprisaXETxADCChEightLoAlarmStatus,
|
|
aprisaXETxADCChEightLoAlarmSeverity,
|
|
aprisaXETxADCChEightLoAlarmEnabled,
|
|
aprisaXETxADCChEightLoAlarmThreshold,
|
|
aprisaXETxADCChEightLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Eight voltage too High alarm group."
|
|
::= { aprisaXEGroups 267 }
|
|
|
|
|
|
aprisaXETxADCChNineHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 41 }
|
|
|
|
aprisaXETxADCChNineHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXETxADCChNineHiAlarm 1 }
|
|
|
|
aprisaXETxADCChNineHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXETxADCChNineHiAlarm 2 }
|
|
|
|
aprisaXETxADCChNineHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXETxADCChNineHiAlarm 3 }
|
|
|
|
aprisaXETxADCChNineHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Nine voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChNineHiAlarm 4 }
|
|
|
|
aprisaXETxADCChNineHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Nine voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChNineHiAlarm 5 }
|
|
|
|
aprisaXETxADCChNineHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Nine voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChNineHiAlarm 6 }
|
|
|
|
aprisaXETxADCChNineHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChNineHiAlarmName,
|
|
aprisaXETxADCChNineHiAlarmStatus,
|
|
aprisaXETxADCChNineHiAlarmSeverity,
|
|
aprisaXETxADCChNineHiAlarmEnabled,
|
|
aprisaXETxADCChNineHiAlarmThreshold,
|
|
aprisaXETxADCChNineHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Nine voltage too high alarm group."
|
|
::= { aprisaXEGroups 268 }
|
|
|
|
|
|
aprisaXETxADCChNineLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 42 }
|
|
|
|
aprisaXETxADCChNineLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXETxADCChNineLoAlarm 1 }
|
|
|
|
aprisaXETxADCChNineLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXETxADCChNineLoAlarm 2 }
|
|
|
|
aprisaXETxADCChNineLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXETxADCChNineLoAlarm 3 }
|
|
|
|
aprisaXETxADCChNineLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Nine voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChNineLoAlarm 4 }
|
|
|
|
aprisaXETxADCChNineLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChNineLoAlarm 5 }
|
|
|
|
aprisaXETxADCChNineLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Nine voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChNineLoAlarm 6 }
|
|
|
|
aprisaXETxADCChNineLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChNineLoAlarmName,
|
|
aprisaXETxADCChNineLoAlarmStatus,
|
|
aprisaXETxADCChNineLoAlarmSeverity,
|
|
aprisaXETxADCChNineLoAlarmEnabled,
|
|
aprisaXETxADCChNineLoAlarmThreshold,
|
|
aprisaXETxADCChNineLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Nine voltage too High alarm group."
|
|
::= { aprisaXEGroups 269 }
|
|
|
|
|
|
aprisaXETxADCChTenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 43 }
|
|
|
|
aprisaXETxADCChTenHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXETxADCChTenHiAlarm 1 }
|
|
|
|
aprisaXETxADCChTenHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXETxADCChTenHiAlarm 2 }
|
|
|
|
aprisaXETxADCChTenHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXETxADCChTenHiAlarm 3 }
|
|
|
|
aprisaXETxADCChTenHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Ten voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChTenHiAlarm 4 }
|
|
|
|
aprisaXETxADCChTenHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Ten voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChTenHiAlarm 5 }
|
|
|
|
aprisaXETxADCChTenHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Ten voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChTenHiAlarm 6 }
|
|
|
|
aprisaXETxADCChTenHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChTenHiAlarmName,
|
|
aprisaXETxADCChTenHiAlarmStatus,
|
|
aprisaXETxADCChTenHiAlarmSeverity,
|
|
aprisaXETxADCChTenHiAlarmEnabled,
|
|
aprisaXETxADCChTenHiAlarmThreshold,
|
|
aprisaXETxADCChTenHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Ten voltage too high alarm group."
|
|
::= { aprisaXEGroups 270 }
|
|
|
|
|
|
aprisaXETxADCChTenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 44 }
|
|
|
|
aprisaXETxADCChTenLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXETxADCChTenLoAlarm 1 }
|
|
|
|
aprisaXETxADCChTenLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXETxADCChTenLoAlarm 2 }
|
|
|
|
aprisaXETxADCChTenLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXETxADCChTenLoAlarm 3 }
|
|
|
|
aprisaXETxADCChTenLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Ten voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChTenLoAlarm 4 }
|
|
|
|
aprisaXETxADCChTenLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChTenLoAlarm 5 }
|
|
|
|
aprisaXETxADCChTenLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Ten voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChTenLoAlarm 6 }
|
|
|
|
aprisaXETxADCChTenLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChTenLoAlarmName,
|
|
aprisaXETxADCChTenLoAlarmStatus,
|
|
aprisaXETxADCChTenLoAlarmSeverity,
|
|
aprisaXETxADCChTenLoAlarmEnabled,
|
|
aprisaXETxADCChTenLoAlarmThreshold,
|
|
aprisaXETxADCChTenLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Ten voltage too High alarm group."
|
|
::= { aprisaXEGroups 271 }
|
|
|
|
|
|
aprisaXETxADCChElevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 45 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Eleven voltage too high alarm."
|
|
::= { aprisaXETxADCChElevenHiAlarm 1 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Eleven voltage too high alarm."
|
|
::= { aprisaXETxADCChElevenHiAlarm 2 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Eleven voltage too high alarm."
|
|
::= { aprisaXETxADCChElevenHiAlarm 3 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Eleven voltage too high alarm is enabled."
|
|
::= { aprisaXETxADCChElevenHiAlarm 4 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eleven voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChElevenHiAlarm 5 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the transmitter ADC Ch Eleven voltage too high
|
|
will be cleared."
|
|
::= { aprisaXETxADCChElevenHiAlarm 6 }
|
|
|
|
aprisaXETxADCChElevenHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChElevenHiAlarmName,
|
|
aprisaXETxADCChElevenHiAlarmStatus,
|
|
aprisaXETxADCChElevenHiAlarmSeverity,
|
|
aprisaXETxADCChElevenHiAlarmEnabled,
|
|
aprisaXETxADCChElevenHiAlarmThreshold,
|
|
aprisaXETxADCChElevenHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Eleven voltage too high alarm group."
|
|
::= { aprisaXEGroups 272 }
|
|
|
|
|
|
aprisaXETxADCChElevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXETransmitterAlarms 46 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the transmitter ADC Ch Eleven voltage too low alarm."
|
|
::= { aprisaXETxADCChElevenLoAlarm 1 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the transmitter ADC Ch Eleven voltage too low alarm."
|
|
::= { aprisaXETxADCChElevenLoAlarm 2 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the transmitter ADC Ch Eleven voltage too low alarm."
|
|
::= { aprisaXETxADCChElevenLoAlarm 3 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the transmitter ADC Ch Eleven voltage too low alarm is enabled."
|
|
::= { aprisaXETxADCChElevenLoAlarm 4 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXETxADCChElevenLoAlarm 5 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the transmitter ADC Ch Eleven voltage too low
|
|
will be cleared."
|
|
::= { aprisaXETxADCChElevenLoAlarm 6 }
|
|
|
|
aprisaXETxADCChElevenLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXETxADCChElevenLoAlarmName,
|
|
aprisaXETxADCChElevenLoAlarmStatus,
|
|
aprisaXETxADCChElevenLoAlarmSeverity,
|
|
aprisaXETxADCChElevenLoAlarmEnabled,
|
|
aprisaXETxADCChElevenLoAlarmThreshold,
|
|
aprisaXETxADCChElevenLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXETx transmitter ADC Ch Eleven voltage too High alarm group."
|
|
::= { aprisaXEGroups 273 }
|
|
|
|
-- ***************************************************************************
|
|
-- End of the Generic Transmitter alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- The Generic Receiver Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXERxADCChZeroHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 19 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXERxADCChZeroHiAlarm 1 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXERxADCChZeroHiAlarm 2 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Zero voltage too high alarm."
|
|
::= { aprisaXERxADCChZeroHiAlarm 3 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Zero voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChZeroHiAlarm 4 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Zero voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChZeroHiAlarm 5 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Zero voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChZeroHiAlarm 6 }
|
|
|
|
aprisaXERxADCChZeroHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChZeroHiAlarmName,
|
|
aprisaXERxADCChZeroHiAlarmStatus,
|
|
aprisaXERxADCChZeroHiAlarmSeverity,
|
|
aprisaXERxADCChZeroHiAlarmEnabled,
|
|
aprisaXERxADCChZeroHiAlarmThreshold,
|
|
aprisaXERxADCChZeroHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Zero voltage too high alarm group."
|
|
::= { aprisaXEGroups 275 }
|
|
|
|
|
|
aprisaXERxADCChZeroLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 20 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXERxADCChZeroLoAlarm 1 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXERxADCChZeroLoAlarm 2 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Zero voltage too low alarm."
|
|
::= { aprisaXERxADCChZeroLoAlarm 3 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Zero voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChZeroLoAlarm 4 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Zero voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChZeroLoAlarm 5 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Zero voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChZeroLoAlarm 6 }
|
|
|
|
aprisaXERxADCChZeroLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChZeroLoAlarmName,
|
|
aprisaXERxADCChZeroLoAlarmStatus,
|
|
aprisaXERxADCChZeroLoAlarmSeverity,
|
|
aprisaXERxADCChZeroLoAlarmEnabled,
|
|
aprisaXERxADCChZeroLoAlarmThreshold,
|
|
aprisaXERxADCChZeroLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Zero voltage too High alarm group."
|
|
::= { aprisaXEGroups 276 }
|
|
|
|
|
|
aprisaXERxADCChOneHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 21 }
|
|
|
|
aprisaXERxADCChOneHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch One voltage too high alarm."
|
|
::= { aprisaXERxADCChOneHiAlarm 1 }
|
|
|
|
aprisaXERxADCChOneHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch One voltage too high alarm."
|
|
::= { aprisaXERxADCChOneHiAlarm 2 }
|
|
|
|
aprisaXERxADCChOneHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch One voltage too high alarm."
|
|
::= { aprisaXERxADCChOneHiAlarm 3 }
|
|
|
|
aprisaXERxADCChOneHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch One voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChOneHiAlarm 4 }
|
|
|
|
aprisaXERxADCChOneHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch One voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChOneHiAlarm 5 }
|
|
|
|
aprisaXERxADCChOneHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch One voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChOneHiAlarm 6 }
|
|
|
|
aprisaXERxADCChOneHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChOneHiAlarmName,
|
|
aprisaXERxADCChOneHiAlarmStatus,
|
|
aprisaXERxADCChOneHiAlarmSeverity,
|
|
aprisaXERxADCChOneHiAlarmEnabled,
|
|
aprisaXERxADCChOneHiAlarmThreshold,
|
|
aprisaXERxADCChOneHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch One voltage too high alarm group."
|
|
::= { aprisaXEGroups 277 }
|
|
|
|
|
|
aprisaXERxADCChOneLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 22 }
|
|
|
|
aprisaXERxADCChOneLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch One voltage too low alarm."
|
|
::= { aprisaXERxADCChOneLoAlarm 1 }
|
|
|
|
aprisaXERxADCChOneLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch One voltage too low alarm."
|
|
::= { aprisaXERxADCChOneLoAlarm 2 }
|
|
|
|
aprisaXERxADCChOneLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch One voltage too low alarm."
|
|
::= { aprisaXERxADCChOneLoAlarm 3 }
|
|
|
|
aprisaXERxADCChOneLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch One voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChOneLoAlarm 4 }
|
|
|
|
aprisaXERxADCChOneLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch One voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChOneLoAlarm 5 }
|
|
|
|
aprisaXERxADCChOneLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch One voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChOneLoAlarm 6 }
|
|
|
|
aprisaXERxADCChOneLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChOneLoAlarmName,
|
|
aprisaXERxADCChOneLoAlarmStatus,
|
|
aprisaXERxADCChOneLoAlarmSeverity,
|
|
aprisaXERxADCChOneLoAlarmEnabled,
|
|
aprisaXERxADCChOneLoAlarmThreshold,
|
|
aprisaXERxADCChOneLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch One voltage too High alarm group."
|
|
::= { aprisaXEGroups 278 }
|
|
|
|
|
|
aprisaXERxADCChTwoHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 23 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXERxADCChTwoHiAlarm 1 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXERxADCChTwoHiAlarm 2 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Two voltage too high alarm."
|
|
::= { aprisaXERxADCChTwoHiAlarm 3 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Two voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChTwoHiAlarm 4 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Two voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChTwoHiAlarm 5 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Two voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChTwoHiAlarm 6 }
|
|
|
|
aprisaXERxADCChTwoHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChTwoHiAlarmName,
|
|
aprisaXERxADCChTwoHiAlarmStatus,
|
|
aprisaXERxADCChTwoHiAlarmSeverity,
|
|
aprisaXERxADCChTwoHiAlarmEnabled,
|
|
aprisaXERxADCChTwoHiAlarmThreshold,
|
|
aprisaXERxADCChTwoHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Two voltage too high alarm group."
|
|
::= { aprisaXEGroups 279 }
|
|
|
|
|
|
aprisaXERxADCChTwoLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 24 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXERxADCChTwoLoAlarm 1 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXERxADCChTwoLoAlarm 2 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Two voltage too low alarm."
|
|
::= { aprisaXERxADCChTwoLoAlarm 3 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Two voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChTwoLoAlarm 4 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Two voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChTwoLoAlarm 5 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Two voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChTwoLoAlarm 6 }
|
|
|
|
aprisaXERxADCChTwoLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChTwoLoAlarmName,
|
|
aprisaXERxADCChTwoLoAlarmStatus,
|
|
aprisaXERxADCChTwoLoAlarmSeverity,
|
|
aprisaXERxADCChTwoLoAlarmEnabled,
|
|
aprisaXERxADCChTwoLoAlarmThreshold,
|
|
aprisaXERxADCChTwoLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Two voltage too High alarm group."
|
|
::= { aprisaXEGroups 280 }
|
|
|
|
|
|
aprisaXERxADCChThreeHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 25 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXERxADCChThreeHiAlarm 1 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXERxADCChThreeHiAlarm 2 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Three voltage too high alarm."
|
|
::= { aprisaXERxADCChThreeHiAlarm 3 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Three voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChThreeHiAlarm 4 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Three voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChThreeHiAlarm 5 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Three voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChThreeHiAlarm 6 }
|
|
|
|
aprisaXERxADCChThreeHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChThreeHiAlarmName,
|
|
aprisaXERxADCChThreeHiAlarmStatus,
|
|
aprisaXERxADCChThreeHiAlarmSeverity,
|
|
aprisaXERxADCChThreeHiAlarmEnabled,
|
|
aprisaXERxADCChThreeHiAlarmThreshold,
|
|
aprisaXERxADCChThreeHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Three voltage too high alarm group."
|
|
::= { aprisaXEGroups 281 }
|
|
|
|
|
|
aprisaXERxADCChThreeLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 26 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXERxADCChThreeLoAlarm 1 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXERxADCChThreeLoAlarm 2 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Three voltage too low alarm."
|
|
::= { aprisaXERxADCChThreeLoAlarm 3 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Three voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChThreeLoAlarm 4 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Three voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChThreeLoAlarm 5 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Three voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChThreeLoAlarm 6 }
|
|
|
|
aprisaXERxADCChThreeLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChThreeLoAlarmName,
|
|
aprisaXERxADCChThreeLoAlarmStatus,
|
|
aprisaXERxADCChThreeLoAlarmSeverity,
|
|
aprisaXERxADCChThreeLoAlarmEnabled,
|
|
aprisaXERxADCChThreeLoAlarmThreshold,
|
|
aprisaXERxADCChThreeLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Three voltage too High alarm group."
|
|
::= { aprisaXEGroups 282 }
|
|
|
|
|
|
aprisaXERxADCChFourHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 27 }
|
|
|
|
aprisaXERxADCChFourHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXERxADCChFourHiAlarm 1 }
|
|
|
|
aprisaXERxADCChFourHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXERxADCChFourHiAlarm 2 }
|
|
|
|
aprisaXERxADCChFourHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Four voltage too high alarm."
|
|
::= { aprisaXERxADCChFourHiAlarm 3 }
|
|
|
|
aprisaXERxADCChFourHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Four voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChFourHiAlarm 4 }
|
|
|
|
aprisaXERxADCChFourHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Four voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChFourHiAlarm 5 }
|
|
|
|
aprisaXERxADCChFourHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Four voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChFourHiAlarm 6 }
|
|
|
|
aprisaXERxADCChFourHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChFourHiAlarmName,
|
|
aprisaXERxADCChFourHiAlarmStatus,
|
|
aprisaXERxADCChFourHiAlarmSeverity,
|
|
aprisaXERxADCChFourHiAlarmEnabled,
|
|
aprisaXERxADCChFourHiAlarmThreshold,
|
|
aprisaXERxADCChFourHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Four voltage too high alarm group."
|
|
::= { aprisaXEGroups 283 }
|
|
|
|
|
|
aprisaXERxADCChFourLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 28 }
|
|
|
|
aprisaXERxADCChFourLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXERxADCChFourLoAlarm 1 }
|
|
|
|
aprisaXERxADCChFourLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXERxADCChFourLoAlarm 2 }
|
|
|
|
aprisaXERxADCChFourLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Four voltage too low alarm."
|
|
::= { aprisaXERxADCChFourLoAlarm 3 }
|
|
|
|
aprisaXERxADCChFourLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Four voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChFourLoAlarm 4 }
|
|
|
|
aprisaXERxADCChFourLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Four voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChFourLoAlarm 5 }
|
|
|
|
aprisaXERxADCChFourLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Four voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChFourLoAlarm 6 }
|
|
|
|
aprisaXERxADCChFourLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChFourLoAlarmName,
|
|
aprisaXERxADCChFourLoAlarmStatus,
|
|
aprisaXERxADCChFourLoAlarmSeverity,
|
|
aprisaXERxADCChFourLoAlarmEnabled,
|
|
aprisaXERxADCChFourLoAlarmThreshold,
|
|
aprisaXERxADCChFourLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Four voltage too High alarm group."
|
|
::= { aprisaXEGroups 284 }
|
|
|
|
|
|
aprisaXERxADCChFiveHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 29 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXERxADCChFiveHiAlarm 1 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXERxADCChFiveHiAlarm 2 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Five voltage too high alarm."
|
|
::= { aprisaXERxADCChFiveHiAlarm 3 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Five voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChFiveHiAlarm 4 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Five voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChFiveHiAlarm 5 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Five voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChFiveHiAlarm 6 }
|
|
|
|
aprisaXERxADCChFiveHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChFiveHiAlarmName,
|
|
aprisaXERxADCChFiveHiAlarmStatus,
|
|
aprisaXERxADCChFiveHiAlarmSeverity,
|
|
aprisaXERxADCChFiveHiAlarmEnabled,
|
|
aprisaXERxADCChFiveHiAlarmThreshold,
|
|
aprisaXERxADCChFiveHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Five voltage too high alarm group."
|
|
::= { aprisaXEGroups 285 }
|
|
|
|
|
|
aprisaXERxADCChFiveLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 30 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXERxADCChFiveLoAlarm 1 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXERxADCChFiveLoAlarm 2 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Five voltage too low alarm."
|
|
::= { aprisaXERxADCChFiveLoAlarm 3 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Five voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChFiveLoAlarm 4 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Five voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChFiveLoAlarm 5 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Five voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChFiveLoAlarm 6 }
|
|
|
|
aprisaXERxADCChFiveLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChFiveLoAlarmName,
|
|
aprisaXERxADCChFiveLoAlarmStatus,
|
|
aprisaXERxADCChFiveLoAlarmSeverity,
|
|
aprisaXERxADCChFiveLoAlarmEnabled,
|
|
aprisaXERxADCChFiveLoAlarmThreshold,
|
|
aprisaXERxADCChFiveLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Five voltage too High alarm group."
|
|
::= { aprisaXEGroups 286 }
|
|
|
|
|
|
aprisaXERxADCChSixHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 31 }
|
|
|
|
aprisaXERxADCChSixHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXERxADCChSixHiAlarm 1 }
|
|
|
|
aprisaXERxADCChSixHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXERxADCChSixHiAlarm 2 }
|
|
|
|
aprisaXERxADCChSixHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Six voltage too high alarm."
|
|
::= { aprisaXERxADCChSixHiAlarm 3 }
|
|
|
|
aprisaXERxADCChSixHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Six voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChSixHiAlarm 4 }
|
|
|
|
aprisaXERxADCChSixHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Six voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChSixHiAlarm 5 }
|
|
|
|
aprisaXERxADCChSixHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Six voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChSixHiAlarm 6 }
|
|
|
|
aprisaXERxADCChSixHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChSixHiAlarmName,
|
|
aprisaXERxADCChSixHiAlarmStatus,
|
|
aprisaXERxADCChSixHiAlarmSeverity,
|
|
aprisaXERxADCChSixHiAlarmEnabled,
|
|
aprisaXERxADCChSixHiAlarmThreshold,
|
|
aprisaXERxADCChSixHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Six voltage too high alarm group."
|
|
::= { aprisaXEGroups 287 }
|
|
|
|
|
|
aprisaXERxADCChSixLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 32 }
|
|
|
|
aprisaXERxADCChSixLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXERxADCChSixLoAlarm 1 }
|
|
|
|
aprisaXERxADCChSixLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXERxADCChSixLoAlarm 2 }
|
|
|
|
aprisaXERxADCChSixLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Six voltage too low alarm."
|
|
::= { aprisaXERxADCChSixLoAlarm 3 }
|
|
|
|
aprisaXERxADCChSixLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Six voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChSixLoAlarm 4 }
|
|
|
|
aprisaXERxADCChSixLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Six voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChSixLoAlarm 5 }
|
|
|
|
aprisaXERxADCChSixLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Six voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChSixLoAlarm 6 }
|
|
|
|
aprisaXERxADCChSixLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChSixLoAlarmName,
|
|
aprisaXERxADCChSixLoAlarmStatus,
|
|
aprisaXERxADCChSixLoAlarmSeverity,
|
|
aprisaXERxADCChSixLoAlarmEnabled,
|
|
aprisaXERxADCChSixLoAlarmThreshold,
|
|
aprisaXERxADCChSixLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Six voltage too High alarm group."
|
|
::= { aprisaXEGroups 288 }
|
|
|
|
|
|
aprisaXERxADCChSevenHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 33 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXERxADCChSevenHiAlarm 1 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXERxADCChSevenHiAlarm 2 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Seven voltage too high alarm."
|
|
::= { aprisaXERxADCChSevenHiAlarm 3 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Seven voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChSevenHiAlarm 4 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Seven voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChSevenHiAlarm 5 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Seven voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChSevenHiAlarm 6 }
|
|
|
|
aprisaXERxADCChSevenHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChSevenHiAlarmName,
|
|
aprisaXERxADCChSevenHiAlarmStatus,
|
|
aprisaXERxADCChSevenHiAlarmSeverity,
|
|
aprisaXERxADCChSevenHiAlarmEnabled,
|
|
aprisaXERxADCChSevenHiAlarmThreshold,
|
|
aprisaXERxADCChSevenHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Seven voltage too high alarm group."
|
|
::= { aprisaXEGroups 289 }
|
|
|
|
|
|
aprisaXERxADCChSevenLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 34 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXERxADCChSevenLoAlarm 1 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXERxADCChSevenLoAlarm 2 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Seven voltage too low alarm."
|
|
::= { aprisaXERxADCChSevenLoAlarm 3 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Seven voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChSevenLoAlarm 4 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Seven voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChSevenLoAlarm 5 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Seven voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChSevenLoAlarm 6 }
|
|
|
|
aprisaXERxADCChSevenLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChSevenLoAlarmName,
|
|
aprisaXERxADCChSevenLoAlarmStatus,
|
|
aprisaXERxADCChSevenLoAlarmSeverity,
|
|
aprisaXERxADCChSevenLoAlarmEnabled,
|
|
aprisaXERxADCChSevenLoAlarmThreshold,
|
|
aprisaXERxADCChSevenLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Seven voltage too High alarm group."
|
|
::= { aprisaXEGroups 290 }
|
|
|
|
|
|
aprisaXERxADCChEightHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 35 }
|
|
|
|
aprisaXERxADCChEightHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXERxADCChEightHiAlarm 1 }
|
|
|
|
aprisaXERxADCChEightHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXERxADCChEightHiAlarm 2 }
|
|
|
|
aprisaXERxADCChEightHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Eight voltage too high alarm."
|
|
::= { aprisaXERxADCChEightHiAlarm 3 }
|
|
|
|
aprisaXERxADCChEightHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Eight voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChEightHiAlarm 4 }
|
|
|
|
aprisaXERxADCChEightHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Eight voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChEightHiAlarm 5 }
|
|
|
|
aprisaXERxADCChEightHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Eight voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChEightHiAlarm 6 }
|
|
|
|
aprisaXERxADCChEightHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChEightHiAlarmName,
|
|
aprisaXERxADCChEightHiAlarmStatus,
|
|
aprisaXERxADCChEightHiAlarmSeverity,
|
|
aprisaXERxADCChEightHiAlarmEnabled,
|
|
aprisaXERxADCChEightHiAlarmThreshold,
|
|
aprisaXERxADCChEightHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Eight voltage too high alarm group."
|
|
::= { aprisaXEGroups 291 }
|
|
|
|
|
|
aprisaXERxADCChEightLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 36 }
|
|
|
|
aprisaXERxADCChEightLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXERxADCChEightLoAlarm 1 }
|
|
|
|
aprisaXERxADCChEightLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXERxADCChEightLoAlarm 2 }
|
|
|
|
aprisaXERxADCChEightLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Eight voltage too low alarm."
|
|
::= { aprisaXERxADCChEightLoAlarm 3 }
|
|
|
|
aprisaXERxADCChEightLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Eight voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChEightLoAlarm 4 }
|
|
|
|
aprisaXERxADCChEightLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Eight voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChEightLoAlarm 5 }
|
|
|
|
aprisaXERxADCChEightLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Eight voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChEightLoAlarm 6 }
|
|
|
|
aprisaXERxADCChEightLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChEightLoAlarmName,
|
|
aprisaXERxADCChEightLoAlarmStatus,
|
|
aprisaXERxADCChEightLoAlarmSeverity,
|
|
aprisaXERxADCChEightLoAlarmEnabled,
|
|
aprisaXERxADCChEightLoAlarmThreshold,
|
|
aprisaXERxADCChEightLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Eight voltage too High alarm group."
|
|
::= { aprisaXEGroups 292 }
|
|
|
|
|
|
aprisaXERxADCChNineHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 37 }
|
|
|
|
aprisaXERxADCChNineHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXERxADCChNineHiAlarm 1 }
|
|
|
|
aprisaXERxADCChNineHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXERxADCChNineHiAlarm 2 }
|
|
|
|
aprisaXERxADCChNineHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Nine voltage too high alarm."
|
|
::= { aprisaXERxADCChNineHiAlarm 3 }
|
|
|
|
aprisaXERxADCChNineHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Nine voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChNineHiAlarm 4 }
|
|
|
|
aprisaXERxADCChNineHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Nine voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChNineHiAlarm 5 }
|
|
|
|
aprisaXERxADCChNineHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Nine voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChNineHiAlarm 6 }
|
|
|
|
aprisaXERxADCChNineHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChNineHiAlarmName,
|
|
aprisaXERxADCChNineHiAlarmStatus,
|
|
aprisaXERxADCChNineHiAlarmSeverity,
|
|
aprisaXERxADCChNineHiAlarmEnabled,
|
|
aprisaXERxADCChNineHiAlarmThreshold,
|
|
aprisaXERxADCChNineHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Nine voltage too high alarm group."
|
|
::= { aprisaXEGroups 293 }
|
|
|
|
|
|
aprisaXERxADCChNineLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 38 }
|
|
|
|
aprisaXERxADCChNineLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXERxADCChNineLoAlarm 1 }
|
|
|
|
aprisaXERxADCChNineLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXERxADCChNineLoAlarm 2 }
|
|
|
|
aprisaXERxADCChNineLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Nine voltage too low alarm."
|
|
::= { aprisaXERxADCChNineLoAlarm 3 }
|
|
|
|
aprisaXERxADCChNineLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Nine voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChNineLoAlarm 4 }
|
|
|
|
aprisaXERxADCChNineLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Nine voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChNineLoAlarm 5 }
|
|
|
|
aprisaXERxADCChNineLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Nine voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChNineLoAlarm 6 }
|
|
|
|
aprisaXERxADCChNineLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChNineLoAlarmName,
|
|
aprisaXERxADCChNineLoAlarmStatus,
|
|
aprisaXERxADCChNineLoAlarmSeverity,
|
|
aprisaXERxADCChNineLoAlarmEnabled,
|
|
aprisaXERxADCChNineLoAlarmThreshold,
|
|
aprisaXERxADCChNineLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Nine voltage too High alarm group."
|
|
::= { aprisaXEGroups 294 }
|
|
|
|
|
|
aprisaXERxADCChTenHiAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 39 }
|
|
|
|
aprisaXERxADCChTenHiAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXERxADCChTenHiAlarm 1 }
|
|
|
|
aprisaXERxADCChTenHiAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXERxADCChTenHiAlarm 2 }
|
|
|
|
aprisaXERxADCChTenHiAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Ten voltage too high alarm."
|
|
::= { aprisaXERxADCChTenHiAlarm 3 }
|
|
|
|
aprisaXERxADCChTenHiAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Ten voltage too high alarm is enabled."
|
|
::= { aprisaXERxADCChTenHiAlarm 4 }
|
|
|
|
aprisaXERxADCChTenHiAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Ten voltage too high
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChTenHiAlarm 5 }
|
|
|
|
aprisaXERxADCChTenHiAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at which the receiver ADC Ch Ten voltage too high
|
|
will be cleared."
|
|
::= { aprisaXERxADCChTenHiAlarm 6 }
|
|
|
|
aprisaXERxADCChTenHiAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChTenHiAlarmName,
|
|
aprisaXERxADCChTenHiAlarmStatus,
|
|
aprisaXERxADCChTenHiAlarmSeverity,
|
|
aprisaXERxADCChTenHiAlarmEnabled,
|
|
aprisaXERxADCChTenHiAlarmThreshold,
|
|
aprisaXERxADCChTenHiAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Ten voltage too high alarm group."
|
|
::= { aprisaXEGroups 295 }
|
|
|
|
|
|
aprisaXERxADCChTenLoAlarm OBJECT IDENTIFIER ::= { aprisaXEReceiverAlarms 40 }
|
|
|
|
aprisaXERxADCChTenLoAlarmName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The name of the receiver ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXERxADCChTenLoAlarm 1 }
|
|
|
|
aprisaXERxADCChTenLoAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the receiver ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXERxADCChTenLoAlarm 2 }
|
|
|
|
aprisaXERxADCChTenLoAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the receiver ADC Ch Ten voltage too low alarm."
|
|
::= { aprisaXERxADCChTenLoAlarm 3 }
|
|
|
|
aprisaXERxADCChTenLoAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the receiver ADC Ch Ten voltage too low alarm is enabled."
|
|
::= { aprisaXERxADCChTenLoAlarm 4 }
|
|
|
|
aprisaXERxADCChTenLoAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Ten voltage too low
|
|
alarm will be set."
|
|
::= { aprisaXERxADCChTenLoAlarm 5 }
|
|
|
|
aprisaXERxADCChTenLoAlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the level at wLoch the receiver ADC Ch Ten voltage too low
|
|
will be cleared."
|
|
::= { aprisaXERxADCChTenLoAlarm 6 }
|
|
|
|
aprisaXERxADCChTenLoAlarmsGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXERxADCChTenLoAlarmName,
|
|
aprisaXERxADCChTenLoAlarmStatus,
|
|
aprisaXERxADCChTenLoAlarmSeverity,
|
|
aprisaXERxADCChTenLoAlarmEnabled,
|
|
aprisaXERxADCChTenLoAlarmThreshold,
|
|
aprisaXERxADCChTenLoAlarmClearThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aprisaXERx receiver ADC Ch Ten voltage too High alarm group."
|
|
::= { aprisaXEGroups 296 }
|
|
|
|
-- ***************************************************************************
|
|
-- End of the Generic Receiver alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Modem alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEModemAlarms OBJECT IDENTIFIER ::= { aprisaXELinkAlarms 10 }
|
|
|
|
aprisaXEModemSyncAlarm OBJECT IDENTIFIER ::= { aprisaXEModemAlarms 1 }
|
|
|
|
aprisaXEModemSyncAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the loss of modem sync alarm."
|
|
::= { aprisaXEModemSyncAlarm 1 }
|
|
|
|
aprisaXEModemSyncAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The severity of the loss of modem sync alarm."
|
|
::= { aprisaXEModemSyncAlarm 2 }
|
|
|
|
aprisaXEModemSyncAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the loss of modem sync alarm is enabled."
|
|
::= { aprisaXEModemSyncAlarm 3 }
|
|
|
|
-- ***************************************************************************
|
|
-- End of Modem alarms
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Quad E1 Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEQuadJetBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEQuadJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Quad E1 card specific configuration details."
|
|
::= { aprisaXEObjects 87 }
|
|
|
|
aprisaXEQuadJetBoardEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Quad E1 configuration details."
|
|
INDEX { aprisaXEQuadJetBoardTableIndex }
|
|
::= { aprisaXEQuadJetBoardTable 1 }
|
|
|
|
AprisaXEQuadJetBoardEntry ::= SEQUENCE {
|
|
aprisaXEQuadJetBoardTableIndex INTEGER
|
|
}
|
|
|
|
aprisaXEQuadJetBoardTableIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Quad E1 board indexed by slot."
|
|
::= { aprisaXEQuadJetBoardEntry 1 }
|
|
|
|
aprisaXEQuadJetPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEQuadJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table based on slot and port of QuadJet cards alarms."
|
|
::= { aprisaXEObjects 88 }
|
|
|
|
aprisaXEQuadJetPortEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Quad E1 port alarms."
|
|
INDEX { aprisaXEQuadJetPortTableSlot,
|
|
aprisaXEQuadJetPortTablePort
|
|
}
|
|
::= { aprisaXEQuadJetPortTable 1 }
|
|
|
|
AprisaXEQuadJetPortEntry ::= SEQUENCE {
|
|
aprisaXEQuadJetPortTableSlot INTEGER,
|
|
aprisaXEQuadJetPortTablePort INTEGER,
|
|
aprisaXEQuadJetLOFAlarmStatus INTEGER,
|
|
aprisaXEQuadJetLOFAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetLOFAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetAISAlarmStatus INTEGER,
|
|
aprisaXEQuadJetAISAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetAISAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetRAIAlarmStatus INTEGER,
|
|
aprisaXEQuadJetRAIAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetRAIAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetRMAIAlarmStatus INTEGER,
|
|
aprisaXEQuadJetRMAIAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetRMAIAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetTS16AISAlarmStatus INTEGER,
|
|
aprisaXEQuadJetTS16AISAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetTS16AISAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetTS16LOSAlarmStatus INTEGER,
|
|
aprisaXEQuadJetTS16LOSAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetTS16LOSAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetLOSAlarmStatus INTEGER,
|
|
aprisaXEQuadJetLOSAlarmSeverity INTEGER,
|
|
aprisaXEQuadJetLOSAlarmEnabled INTEGER,
|
|
aprisaXEQuadJetCRC4AlarmStatus INTEGER,
|
|
aprisaXEQuadJetCRC4AlarmSeverity INTEGER,
|
|
aprisaXEQuadJetCRC4AlarmEnabled INTEGER,
|
|
aprisaXEQuadJetCRC4AlarmThreshold Integer32,
|
|
aprisaXEQuadJetCRC4AlarmClearThreshold Integer32
|
|
}
|
|
|
|
aprisaXEQuadJetPortTableSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on slot number."
|
|
::= { aprisaXEQuadJetPortEntry 1 }
|
|
|
|
aprisaXEQuadJetPortTablePort OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on port number."
|
|
::= { aprisaXEQuadJetPortEntry 2 }
|
|
|
|
aprisaXEQuadJetLOFAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Red alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 3 }
|
|
|
|
aprisaXEQuadJetLOFAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Red alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 4 }
|
|
|
|
aprisaXEQuadJetLOFAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Red alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 5 }
|
|
|
|
aprisaXEQuadJetAISAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 6 }
|
|
|
|
aprisaXEQuadJetAISAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 7 }
|
|
|
|
aprisaXEQuadJetAISAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 8 }
|
|
|
|
aprisaXEQuadJetRAIAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RAI alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 9 }
|
|
|
|
aprisaXEQuadJetRAIAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RAI alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 10 }
|
|
|
|
aprisaXEQuadJetRAIAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RAI alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 11 }
|
|
|
|
aprisaXEQuadJetRMAIAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RMAI alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 12 }
|
|
|
|
aprisaXEQuadJetRMAIAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RMAI alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 13 }
|
|
|
|
aprisaXEQuadJetRMAIAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "RMAI alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 14 }
|
|
|
|
aprisaXEQuadJetTS16AISAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 AIS alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 15 }
|
|
|
|
aprisaXEQuadJetTS16AISAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 AIS alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 16 }
|
|
|
|
aprisaXEQuadJetTS16AISAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 AIS alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 17 }
|
|
|
|
aprisaXEQuadJetTS16LOSAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 LOS alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 18 }
|
|
|
|
aprisaXEQuadJetTS16LOSAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 LOS alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 19 }
|
|
|
|
aprisaXEQuadJetTS16LOSAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TS16 LOS alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 20 }
|
|
|
|
aprisaXEQuadJetLOSAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 21 }
|
|
|
|
aprisaXEQuadJetLOSAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 22 }
|
|
|
|
aprisaXEQuadJetLOSAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 23 }
|
|
|
|
aprisaXEQuadJetCRC4AlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CRC4 alarm status."
|
|
::= { aprisaXEQuadJetPortEntry 24 }
|
|
|
|
aprisaXEQuadJetCRC4AlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CRC4 alarm severity."
|
|
::= { aprisaXEQuadJetPortEntry 25 }
|
|
|
|
aprisaXEQuadJetCRC4AlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CRC4 alarm enabled or disabled."
|
|
::= { aprisaXEQuadJetPortEntry 26 }
|
|
|
|
aprisaXEQuadJetCRC4AlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CRC4 Threshold value for counter to alarm at."
|
|
::= { aprisaXEQuadJetPortEntry 27 }
|
|
|
|
aprisaXEQuadJetCRC4AlarmClearThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "CRC4 Threshold at which alarm clears."
|
|
::= { aprisaXEQuadJetPortEntry 28 }
|
|
|
|
|
|
aprisaXEQuadJetIFConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEQuadJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Switch data table which describes the
|
|
allocation of user data on to the TDM busses."
|
|
::= { aprisaXEObjects 90 }
|
|
|
|
aprisaXEQuadJetIFConfigEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Quad JET config data."
|
|
INDEX { aprisaXEQuadJetIFConfigSlotIndex,
|
|
aprisaXEQuadJetIFConfigPortIndex
|
|
}
|
|
::= { aprisaXEQuadJetIFConfigTable 1 }
|
|
|
|
AprisaXEQuadJetIFConfigEntry ::= SEQUENCE {
|
|
aprisaXEQuadJetIFConfigSlotIndex INTEGER,
|
|
aprisaXEQuadJetIFConfigPortIndex INTEGER,
|
|
aprisaXEQuadJetTrafficType INTEGER,
|
|
aprisaXEQuadJetLoopback INTEGER,
|
|
aprisaXEQuadJetLineEncoding INTEGER,
|
|
aprisaXEQuadJetPcmMode INTEGER,
|
|
aprisaXEQuadJetClockSource INTEGER,
|
|
aprisaXEQuadJetLineRadioLoopback INTEGER,
|
|
aprisaXEQuadJetTxWaveFormShaper INTEGER,
|
|
aprisaXEQuadJetMultiframeEnable INTEGER
|
|
}
|
|
|
|
aprisaXEQuadJetIFConfigSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXEQuadJetIFConfigEntry 1 }
|
|
|
|
aprisaXEQuadJetIFConfigPortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXEQuadJetIFConfigEntry 2 }
|
|
|
|
aprisaXEQuadJetTrafficType OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetTrafficType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the traffic type on a Quad JET port."
|
|
::= { aprisaXEQuadJetIFConfigEntry 3 }
|
|
|
|
aprisaXEQuadJetLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Controls the traffic loopback on a Quad JET port."
|
|
::= { aprisaXEQuadJetIFConfigEntry 4 }
|
|
|
|
aprisaXEQuadJetLineEncoding OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLineEncoding
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the line encoding, the default is
|
|
HDB3 for E1, B8ZS for T1."
|
|
::= { aprisaXEQuadJetIFConfigEntry 5 }
|
|
|
|
aprisaXEQuadJetPcmMode OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C."
|
|
::= { aprisaXEQuadJetIFConfigEntry 6 }
|
|
|
|
aprisaXEQuadJetClockSource OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockSelect
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls whether the port drives the clock soure or not."
|
|
::= { aprisaXEQuadJetIFConfigEntry 7 }
|
|
|
|
aprisaXEQuadJetLineRadioLoopback OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLoopbacks
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the E1 loopback setting on a port;
|
|
OFF, Line or Radio Facing."
|
|
::= { aprisaXEQuadJetIFConfigEntry 8 }
|
|
|
|
aprisaXEQuadJetTxWaveFormShaper OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetWaveFormShapers
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port;
|
|
0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft."
|
|
::= { aprisaXEQuadJetIFConfigEntry 9 }
|
|
|
|
aprisaXEQuadJetMultiframeEnable OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetMultiframeEnable
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether support is enabled for transport of T1 SF
|
|
and ESF multiframe sync for a port."
|
|
::= { aprisaXEQuadJetIFConfigEntry 10 }
|
|
|
|
|
|
-- E1 Cross connection table, this maps cross-connection identifiers to
|
|
-- the matching E1 slot and port.
|
|
|
|
aprisaXEQuadJetIFConnectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEQuadJetIFConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Interface connection table which holds all the cross
|
|
connect information for the E1 card."
|
|
::= { aprisaXEObjects 91 }
|
|
|
|
aprisaXEQuadJetIFConnectionTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetIFConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Quad JET cross connection data."
|
|
INDEX { aprisaXEQuadJetIFConnectionID,
|
|
aprisaXEQuadJetIFConnectionAggregateID
|
|
}
|
|
::= { aprisaXEQuadJetIFConnectionTable 1 }
|
|
|
|
AprisaXEQuadJetIFConnectionTableEntry ::= SEQUENCE {
|
|
aprisaXEQuadJetIFConnectionID INTEGER,
|
|
aprisaXEQuadJetIFConnectionAggregateID INTEGER,
|
|
aprisaXEQuadJetIFConnectionSlot INTEGER,
|
|
aprisaXEQuadJetIFConnectionE1Port INTEGER,
|
|
aprisaXEQuadJetIFConnectionType INTEGER
|
|
}
|
|
|
|
aprisaXEQuadJetIFConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Backplane Connection ID."
|
|
::= { aprisaXEQuadJetIFConnectionTableEntry 1 }
|
|
|
|
aprisaXEQuadJetIFConnectionAggregateID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Aggregate ID, 0 if an unframed connection."
|
|
::= { aprisaXEQuadJetIFConnectionTableEntry 2 }
|
|
|
|
aprisaXEQuadJetIFConnectionSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot number that this card is in."
|
|
::= { aprisaXEQuadJetIFConnectionTableEntry 3 }
|
|
|
|
aprisaXEQuadJetIFConnectionE1Port OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port number associated with this connection."
|
|
::= { aprisaXEQuadJetIFConnectionTableEntry 4 }
|
|
|
|
aprisaXEQuadJetIFConnectionType OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetConnectionType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the connection is for data or
|
|
CAS signalling."
|
|
::= { aprisaXEQuadJetIFConnectionTableEntry 5 }
|
|
|
|
|
|
aprisaXEQuadJetIFConnectionControl OBJECT IDENTIFIER ::= { aprisaXEObjects 93 }
|
|
|
|
aprisaXEQuadJetIFControlConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Backplane Connection ID."
|
|
::= { aprisaXEQuadJetIFConnectionControl 1 }
|
|
|
|
aprisaXEQuadJetIFControlAggregateID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Aggregate Connection ID."
|
|
::= { aprisaXEQuadJetIFConnectionControl 2 }
|
|
|
|
aprisaXEQuadJetIFConnectionControlSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Slot number that this card is in."
|
|
::= { aprisaXEQuadJetIFConnectionControl 3 }
|
|
|
|
aprisaXEQuadJetIFConnectionControlE1Port OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Port number associated with this connection."
|
|
::= { aprisaXEQuadJetIFConnectionControl 4 }
|
|
|
|
aprisaXEQuadJetIFConnectionControlType OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetConnectionType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether the connection is for data or
|
|
CAS signalling."
|
|
::= { aprisaXEQuadJetIFConnectionControl 5 }
|
|
|
|
aprisaXEQuadJetIFConnectionControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
addCommand (1),
|
|
deleteCommand (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Command to send to act upon the rows in the QuedJet Interface
|
|
Connection table."
|
|
::= { aprisaXEQuadJetIFConnectionControl 6 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Quad JET
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Ethernet
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEEthernetConfiguration OBJECT IDENTIFIER ::= { aprisaXEObjects 95 }
|
|
|
|
aprisaXEEthernetBandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This controls the bandwidth allocated to
|
|
ethernet in kbps, the minimum block is
|
|
8kbps, values will be rounded up to the
|
|
nearest 8kbps."
|
|
::= { aprisaXEEthernetConfiguration 1 }
|
|
|
|
aprisaXEEthernetManagementBandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This controls the bandwidth available to
|
|
management traffic, a minimum of 8kbps is
|
|
required. Values will be rounded up to
|
|
the nearest 8kbps."
|
|
::= { aprisaXEEthernetConfiguration 2 }
|
|
|
|
aprisaXEEthernetCustomerConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Backplane connection ID for Customer bandwidth."
|
|
::= { aprisaXEEthernetConfiguration 3 }
|
|
|
|
aprisaXEEthernetPBCConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Backplane connection ID for Private Back Channel
|
|
management bandwidth."
|
|
::= { aprisaXEEthernetConfiguration 4 }
|
|
|
|
|
|
-- For now a simple table for basic control/status of the hub ports. Later
|
|
-- we probably want to implement the EtherLike-MIB.
|
|
|
|
aprisaXEEthernetPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEEthernetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table used to control and monitor basic ethernet
|
|
features on the 4-port hub."
|
|
::= { aprisaXEObjects 96 }
|
|
|
|
aprisaXEEthernetPortEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Ethernet port status and configuration."
|
|
INDEX { aprisaXEEthernetPortIndex }
|
|
::= { aprisaXEEthernetPortTable 1 }
|
|
|
|
AprisaXEEthernetPortEntry ::= SEQUENCE {
|
|
aprisaXEEthernetPortIndex INTEGER,
|
|
aprisaXEEthernetAutonegotiationStatus INTEGER,
|
|
aprisaXEEthernetRemoteFaultStatus INTEGER,
|
|
aprisaXEEthernetLinkStatus INTEGER,
|
|
aprisaXEEthernetJabberStatus INTEGER,
|
|
aprisaXEEthernetSpeed INTEGER,
|
|
aprisaXEEthernetDuplexMode INTEGER
|
|
}
|
|
|
|
aprisaXEEthernetPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER ( 1..4 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The port index, there are four ports on the hub."
|
|
::= { aprisaXEEthernetPortEntry 1 }
|
|
|
|
aprisaXEEthernetAutonegotiationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { autoNegotiationNotComplete (0),
|
|
autoNegotiationComplete (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the port auto-negotiation."
|
|
::= { aprisaXEEthernetPortEntry 2 }
|
|
|
|
aprisaXEEthernetRemoteFaultStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { remoteFaultNotDetected (0),
|
|
remoteFaultDetected (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the port remote fault detection."
|
|
::= { aprisaXEEthernetPortEntry 3 }
|
|
|
|
aprisaXEEthernetLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { down (0),
|
|
up (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The status of the port link."
|
|
::= { aprisaXEEthernetPortEntry 4 }
|
|
|
|
aprisaXEEthernetJabberStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { jabberNotDetected (0),
|
|
jabberDetected (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Has jabber been detected on the port?."
|
|
::= { aprisaXEEthernetPortEntry 5 }
|
|
|
|
aprisaXEEthernetSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER { mbps10 (0),
|
|
mbps100 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current port speed, 10 or 100 Mbps."
|
|
::= { aprisaXEEthernetPortEntry 6 }
|
|
|
|
aprisaXEEthernetDuplexMode OBJECT-TYPE
|
|
SYNTAX INTEGER { halfDuplex (0),
|
|
fullDuplex (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current port duplex mode."
|
|
::= { aprisaXEEthernetPortEntry 7 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Ethernet
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Interface Status
|
|
-- ***************************************************************************
|
|
--
|
|
-- A table which maintains the status of the interface cards, the amount of
|
|
-- bandwidth allocated per port and the overall alarm status.
|
|
--
|
|
|
|
aprisaXEInterfaceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEInterfaceTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table used to monitor the current interface status."
|
|
::= { aprisaXEObjects 100 }
|
|
|
|
aprisaXEInterfaceTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEInterfaceTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Interface bandwidth and status."
|
|
INDEX { aprisaXEInterfaceIndex }
|
|
::= { aprisaXEInterfaceTable 1 }
|
|
|
|
AprisaXEInterfaceTableEntry ::= SEQUENCE {
|
|
aprisaXEInterfaceIndex INTEGER,
|
|
aprisaXEInterfaceType INTEGER,
|
|
aprisaXEInterfaceAlarmStatus INTEGER,
|
|
aprisaXEInterfacePort1Bandwidth Unsigned32,
|
|
aprisaXEInterfacePort2Bandwidth Unsigned32,
|
|
aprisaXEInterfacePort3Bandwidth Unsigned32,
|
|
aprisaXEInterfacePort4Bandwidth Unsigned32
|
|
}
|
|
|
|
aprisaXEInterfaceIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The slot containing the interface card, slots 0 to
|
|
8 (AUX or A-H) inclusive may contain interface cards."
|
|
::= { aprisaXEInterfaceTableEntry 1 }
|
|
|
|
aprisaXEInterfaceType OBJECT-TYPE
|
|
SYNTAX AprisaXECardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the type of interface card."
|
|
::= { aprisaXEInterfaceTableEntry 2 }
|
|
|
|
aprisaXEInterfaceAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the current alarm status for the interface."
|
|
::= { aprisaXEInterfaceTableEntry 3 }
|
|
|
|
aprisaXEInterfacePort1Bandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the bandwidth allocated to port 1."
|
|
::= { aprisaXEInterfaceTableEntry 4 }
|
|
|
|
aprisaXEInterfacePort2Bandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the bandwidth allocated to port 2."
|
|
::= { aprisaXEInterfaceTableEntry 5 }
|
|
|
|
aprisaXEInterfacePort3Bandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the bandwidth allocated to port 3."
|
|
::= { aprisaXEInterfaceTableEntry 6 }
|
|
|
|
aprisaXEInterfacePort4Bandwidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the bandwidth allocated to port 4."
|
|
::= { aprisaXEInterfaceTableEntry 7 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Interface Status
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- 4 Wire Interfaces
|
|
-- ***************************************************************************
|
|
|
|
aprisaXE4WirePortControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXE4WirePortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Status and Control table for 4Wire."
|
|
::= { aprisaXEObjects 110 }
|
|
|
|
aprisaXE4WirePortControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXE4WirePortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for 4wire table."
|
|
INDEX { aprisaXE4WireSlotIndex,
|
|
aprisaXE4WirePortIndex
|
|
}
|
|
::= { aprisaXE4WirePortControlTable 1 }
|
|
|
|
AprisaXE4WirePortControlTableEntry ::= SEQUENCE {
|
|
aprisaXE4WireConnectionID INTEGER,
|
|
aprisaXE4WireSlotIndex INTEGER,
|
|
aprisaXE4WirePortIndex INTEGER,
|
|
aprisaXE4WireLoopback INTEGER,
|
|
aprisaXE4WireAdpcmCompression INTEGER,
|
|
aprisaXE4WireRxGain INTEGER,
|
|
aprisaXE4WireTxGain INTEGER,
|
|
aprisaXE4WireEInvert INTEGER,
|
|
aprisaXE4WireMInvert INTEGER,
|
|
aprisaXE4WireSignalling INTEGER,
|
|
aprisaXE4WireSignallingConnectionID INTEGER,
|
|
aprisaXE4WireInputLevel INTEGER,
|
|
aprisaXE4WireOutputLevel INTEGER
|
|
}
|
|
|
|
aprisaXE4WireConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated cross-connect Backplane Connection ID."
|
|
::= { aprisaXE4WirePortControlTableEntry 1 }
|
|
|
|
aprisaXE4WireSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for 4wire Status Control table."
|
|
::= { aprisaXE4WirePortControlTableEntry 2 }
|
|
|
|
aprisaXE4WirePortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Channel index for 4 Wire Control Status table."
|
|
::= { aprisaXE4WirePortControlTableEntry 3 }
|
|
|
|
aprisaXE4WireLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Loopback control on or off for channels."
|
|
::= { aprisaXE4WirePortControlTableEntry 4 }
|
|
|
|
aprisaXE4WireAdpcmCompression OBJECT-TYPE
|
|
SYNTAX AprisaXEAdpcmCompression
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none."
|
|
DEFVAL { none }
|
|
::= { aprisaXE4WirePortControlTableEntry 5 }
|
|
|
|
aprisaXE4WireRxGain OBJECT-TYPE
|
|
SYNTAX AprisaXE4WRxGain
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Rx gain +4 dB to -14 dB in 0.5 dB steps."
|
|
::= { aprisaXE4WirePortControlTableEntry 6 }
|
|
|
|
aprisaXE4WireTxGain OBJECT-TYPE
|
|
SYNTAX AprisaXE4WTxGain
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Tx gain +14 dB to -4 dB in half dB steps."
|
|
::= { aprisaXE4WirePortControlTableEntry 7 }
|
|
|
|
aprisaXE4WireEInvert OBJECT-TYPE
|
|
SYNTAX AprisaXESignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls E on each channel for NORMAL or INVERT polarity."
|
|
::= { aprisaXE4WirePortControlTableEntry 8 }
|
|
|
|
aprisaXE4WireMInvert OBJECT-TYPE
|
|
SYNTAX AprisaXESignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls M on each channel for NORMAL or INVERT polarity."
|
|
::= { aprisaXE4WirePortControlTableEntry 9 }
|
|
|
|
aprisaXE4WireSignalling OBJECT-TYPE
|
|
SYNTAX INTEGER { signallingOff (0),
|
|
signallingOn (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enables or disables E&M signalling for the port."
|
|
::= { aprisaXE4WirePortControlTableEntry 10 }
|
|
|
|
aprisaXE4WireSignallingConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated signalling cross-connect Backplane Connection ID."
|
|
::= { aprisaXE4WirePortControlTableEntry 11 }
|
|
|
|
aprisaXE4WireInputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXE4WInputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Input Level -14.0 dBr to +4.0 dBr in half dB steps."
|
|
::= { aprisaXE4WirePortControlTableEntry 12 }
|
|
|
|
aprisaXE4WireOutputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXE4WOutputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Output Level -14.0 dBr to +4.0 dBr in 0.5 dB steps."
|
|
::= { aprisaXE4WirePortControlTableEntry 13 }
|
|
|
|
--
|
|
-- End of aprisaXE4WirePortControlTable
|
|
--
|
|
|
|
|
|
aprisaXE4WireStatusControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXE4WireStatusControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Overall card control and status."
|
|
::= { aprisaXEObjects 121 }
|
|
|
|
aprisaXE4WireStatusControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXE4WireStatusControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Status control entries."
|
|
INDEX { aprisaXE4WireStatusControlSlotIndex }
|
|
::= { aprisaXE4WireStatusControlTable 1 }
|
|
|
|
AprisaXE4WireStatusControlTableEntry ::= SEQUENCE {
|
|
aprisaXE4WireStatusControlSlotIndex INTEGER,
|
|
aprisaXE4WirePcmLaw INTEGER
|
|
}
|
|
|
|
aprisaXE4WireStatusControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index for table."
|
|
::= { aprisaXE4WireStatusControlTableEntry 1 }
|
|
|
|
|
|
aprisaXE4WirePcmLaw OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmLaw
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Sets A-law or u-law."
|
|
::= { aprisaXE4WireStatusControlTableEntry 2 }
|
|
|
|
-- ***************************************************************************
|
|
-- End 4 Wire
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- FXO
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEFXOPortControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEFXOPortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Port Control table for FXO."
|
|
::= { aprisaXEObjects 130 }
|
|
|
|
aprisaXEFXOPortControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEFXOPortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for FXO table."
|
|
INDEX { aprisaXEFXOPortControlSlotIndex,
|
|
aprisaXEFXOPortIndex
|
|
}
|
|
::= { aprisaXEFXOPortControlTable 1 }
|
|
|
|
AprisaXEFXOPortControlTableEntry ::= SEQUENCE {
|
|
aprisaXEFXOPortControlSlotIndex INTEGER,
|
|
aprisaXEFXOPortIndex INTEGER,
|
|
aprisaXEFXOLoopback INTEGER,
|
|
aprisaXEFXOAdpcmCompression INTEGER,
|
|
aprisaXEFXORxGain INTEGER,
|
|
aprisaXEFXOTxGain INTEGER,
|
|
aprisaXEFXOConnectionID INTEGER,
|
|
aprisaXEFXOSignallingConnectionID INTEGER,
|
|
aprisaXEFXOInputLevel INTEGER,
|
|
aprisaXEFXOOutputLevel INTEGER
|
|
}
|
|
|
|
aprisaXEFXOPortControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for FXO Control table."
|
|
::= { aprisaXEFXOPortControlTableEntry 1 }
|
|
|
|
aprisaXEFXOPortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port index for FXO Control table."
|
|
::= { aprisaXEFXOPortControlTableEntry 2 }
|
|
|
|
aprisaXEFXOLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Loopback control on or off for ports."
|
|
::= { aprisaXEFXOPortControlTableEntry 3 }
|
|
|
|
aprisaXEFXOAdpcmCompression OBJECT-TYPE
|
|
SYNTAX AprisaXEAdpcmCompression
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none."
|
|
DEFVAL { none }
|
|
::= { aprisaXEFXOPortControlTableEntry 4 }
|
|
|
|
aprisaXEFXORxGain OBJECT-TYPE
|
|
SYNTAX INTEGER { fxopos100 (0),
|
|
fxopos95 (1),
|
|
fxopos90 (2),
|
|
fxopos85 (3),
|
|
fxopos80 (4),
|
|
fxopos75 (5),
|
|
fxopos70 (6),
|
|
fxopos65 (7),
|
|
fxopos60 (8),
|
|
fxopos55 (9),
|
|
fxopos50 (10),
|
|
fxopos45 (11),
|
|
fxopos40 (12),
|
|
fxopos35 (13),
|
|
fxopos30 (14),
|
|
fxopos25 (15),
|
|
fxopos20 (16),
|
|
fxopos15 (17),
|
|
fxopos10 (18),
|
|
fxopos05 (19),
|
|
fxopos0 (20),
|
|
fxoneg05 (21),
|
|
fxoneg10 (22),
|
|
fxoneg15 (23),
|
|
fxoneg20 (24),
|
|
fxoneg25 (25),
|
|
fxoneg30 (26),
|
|
fxoneg35 (27),
|
|
fxoneg40 (28),
|
|
fxoneg45 (29),
|
|
fxoneg50 (30),
|
|
fxoneg55 (31),
|
|
fxoneg60 (32),
|
|
fxoneg65 (33),
|
|
fxoneg70 (34),
|
|
fxoneg75 (35),
|
|
fxoneg80 (36),
|
|
fxoneg85 (37),
|
|
fxoneg90 (38),
|
|
fxoneg95 (39),
|
|
fxoneg100 (40)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Rx gain -10 dB to 10 dB in 0.5 dB steps."
|
|
::= { aprisaXEFXOPortControlTableEntry 5 }
|
|
|
|
aprisaXEFXOTxGain OBJECT-TYPE
|
|
SYNTAX INTEGER { fxopos100 (0),
|
|
fxopos95 (1),
|
|
fxopos90 (2),
|
|
fxopos85 (3),
|
|
fxopos80 (4),
|
|
fxopos75 (5),
|
|
fxopos70 (6),
|
|
fxopos65 (7),
|
|
fxopos60 (8),
|
|
fxopos55 (9),
|
|
fxopos50 (10),
|
|
fxopos45 (11),
|
|
fxopos40 (12),
|
|
fxopos35 (13),
|
|
fxopos30 (14),
|
|
fxopos25 (15),
|
|
fxopos20 (16),
|
|
fxopos15 (17),
|
|
fxopos10 (18),
|
|
fxopos05 (19),
|
|
fxopos0 (20),
|
|
fxoneg05 (21),
|
|
fxoneg10 (22),
|
|
fxoneg15 (23),
|
|
fxoneg20 (24),
|
|
fxoneg25 (25),
|
|
fxoneg30 (26),
|
|
fxoneg35 (27),
|
|
fxoneg40 (28),
|
|
fxoneg45 (29),
|
|
fxoneg50 (30),
|
|
fxoneg55 (31),
|
|
fxoneg60 (32),
|
|
fxoneg65 (33),
|
|
fxoneg70 (34),
|
|
fxoneg75 (35),
|
|
fxoneg80 (36),
|
|
fxoneg85 (37),
|
|
fxoneg90 (38),
|
|
fxoneg95 (39),
|
|
fxoneg100 (40)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Tx gain -10 dB to 10 dB in half dB steps."
|
|
::= { aprisaXEFXOPortControlTableEntry 6 }
|
|
|
|
aprisaXEFXOConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated cross-connect Backplane Connection ID."
|
|
::= { aprisaXEFXOPortControlTableEntry 7 }
|
|
|
|
aprisaXEFXOSignallingConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated signalling cross-connect Backplane Connection ID."
|
|
::= { aprisaXEFXOPortControlTableEntry 8 }
|
|
|
|
aprisaXEFXOInputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXEFXOInputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Input Level -10.0 dBr to +1.0 dBr in half dB steps."
|
|
::= { aprisaXEFXOPortControlTableEntry 9 }
|
|
|
|
aprisaXEFXOOutputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXEFXOOutputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Output Level -10.0 dBr to +1.0 dBr in 0.5 dB steps."
|
|
::= { aprisaXEFXOPortControlTableEntry 10 }
|
|
|
|
--
|
|
-- end of table
|
|
--
|
|
|
|
aprisaXEFXOControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEFXOControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Control table for FXO."
|
|
::= { aprisaXEObjects 140 }
|
|
|
|
aprisaXEFXOControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEFXOControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for FXO table."
|
|
INDEX { aprisaXEFXOControlSlotIndex }
|
|
::= { aprisaXEFXOControlTable 1 }
|
|
|
|
AprisaXEFXOControlTableEntry ::= SEQUENCE {
|
|
aprisaXEFXOControlSlotIndex INTEGER,
|
|
aprisaXEFXOSPMBandwidth INTEGER,
|
|
aprisaXEFXOSPMFrequency INTEGER,
|
|
aprisaXEFXOSPMLevel INTEGER,
|
|
aprisaXEFXOCasMode INTEGER,
|
|
aprisaXEFXOCasSignal INTEGER,
|
|
aprisaXEFXOPCMLaw INTEGER,
|
|
aprisaXEFXOOnHookSpeed INTEGER,
|
|
aprisaXEFXORingerImpedance INTEGER,
|
|
aprisaXEFXORingerThreshold INTEGER,
|
|
aprisaXEFXOLoopCurrentLimit INTEGER,
|
|
aprisaXEFXOMinLoopCurrent INTEGER,
|
|
aprisaXEFXOTipRingVoltage INTEGER,
|
|
aprisaXEFXOLineImpedance INTEGER,
|
|
aprisaXEFXOLineReversal INTEGER,
|
|
aprisaXEFXOABitFault INTEGER,
|
|
aprisaXEFXOBBitRing INTEGER,
|
|
aprisaXEFXOCBitBilling INTEGER,
|
|
aprisaXEFXODBitReversals INTEGER,
|
|
aprisaXEFXOEchoCanceller INTEGER,
|
|
aprisaXEFXOABitOffHook INTEGER
|
|
}
|
|
|
|
aprisaXEFXOControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for FXO Control table."
|
|
::= { aprisaXEFXOControlTableEntry 1 }
|
|
|
|
aprisaXEFXOSPMBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER { perc15 (0),
|
|
perc35 (1),
|
|
perc55 (2),
|
|
perc75 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the spm detector bandwidth to 1.5%, 3.5%, 5.5% or 7.5%."
|
|
::= { aprisaXEFXOControlTableEntry 2 }
|
|
|
|
aprisaXEFXOSPMFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER { khz12 (0),
|
|
khz16 (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the spm detector frequency to 12kHz or 16kHz."
|
|
::= { aprisaXEFXOControlTableEntry 3 }
|
|
|
|
aprisaXEFXOSPMLevel OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSPMLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the spm detector level 0 to 27 dB."
|
|
::= { aprisaXEFXOControlTableEntry 4 }
|
|
|
|
aprisaXEFXOCasMode OBJECT-TYPE
|
|
SYNTAX INTEGER { casxe (0),
|
|
casse (1),
|
|
cas4w (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS mode to XE,SE or 4Wire compatible."
|
|
::= { aprisaXEFXOControlTableEntry 5 }
|
|
|
|
aprisaXEFXOCasSignal OBJECT-TYPE
|
|
SYNTAX AprisaXESignalState
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Set the CAS signal to normal or invert."
|
|
::= { aprisaXEFXOControlTableEntry 6 }
|
|
|
|
aprisaXEFXOPCMLaw OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmLaw
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the PCM law to A-law or u-law."
|
|
::= { aprisaXEFXOControlTableEntry 7 }
|
|
|
|
aprisaXEFXOOnHookSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER { ohsFast (0),
|
|
ohsMedium (1),
|
|
ohsSlow (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the on hook speed to fast, medium or slow."
|
|
::= { aprisaXEFXOControlTableEntry 8 }
|
|
|
|
aprisaXEFXORingerImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER { rzHigh (0),
|
|
rxSynthesized (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the ringer impedance to high or synthesized."
|
|
::= { aprisaXEFXOControlTableEntry 9 }
|
|
|
|
aprisaXEFXORingerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER { rtLow (0),
|
|
rtMedium (1),
|
|
rtHigh (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the ringer threshold to low, medium or high."
|
|
::= { aprisaXEFXOControlTableEntry 10 }
|
|
|
|
aprisaXEFXOLoopCurrentLimit OBJECT-TYPE
|
|
SYNTAX INTEGER { ilimOff (0),
|
|
ilimOn (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the loop current limiter to off or on."
|
|
::= { aprisaXEFXOControlTableEntry 11 }
|
|
|
|
aprisaXEFXOMinLoopCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER { miniLow (0),
|
|
miniMedium (1),
|
|
miniHigh (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the min loop current to low, medium or high."
|
|
::= { aprisaXEFXOControlTableEntry 12 }
|
|
|
|
aprisaXEFXOTipRingVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER { dcvLow (0),
|
|
dcvMedium (1),
|
|
dcvHigh (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the tip ring voltage to low, medium or high."
|
|
::= { aprisaXEFXOControlTableEntry 13 }
|
|
|
|
aprisaXEFXOLineImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER { acim0 (0),
|
|
acim1 (1),
|
|
acim11 (2),
|
|
acim13 (3),
|
|
acim3 (4),
|
|
acim2 (5),
|
|
acim4 (6),
|
|
acim9 (7),
|
|
acim10 (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the line impedance to 600 Ohms, 900 Ohms,
|
|
600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF,
|
|
TN12 - 220 Ohms + (820 Ohms || 120 nF),
|
|
TBR21 - 270 Ohms + (750 Ohms || 150 nF),
|
|
BT3 - 370 Ohms + (620 Ohms || 310 nF),
|
|
BT Network - 320 Ohms + (1050 Ohms || 210 nF),
|
|
China - 200 Ohms + (680 Ohms || 100 nF)"
|
|
::= { aprisaXEFXOControlTableEntry 14 }
|
|
|
|
aprisaXEFXOLineReversal OBJECT-TYPE
|
|
SYNTAX INTEGER { fxoLineRevOn (0),
|
|
fxoLineRevOff (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Set the line reversal on/off."
|
|
::= { aprisaXEFXOControlTableEntry 15 }
|
|
|
|
aprisaXEFXOABitFault OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS A fault bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXOControlTableEntry 16 }
|
|
|
|
aprisaXEFXOBBitRing OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS B ring bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXOControlTableEntry 17 }
|
|
|
|
aprisaXEFXOCBitBilling OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS C billing bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXOControlTableEntry 18 }
|
|
|
|
aprisaXEFXODBitReversals OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS D reversals bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXOControlTableEntry 19 }
|
|
|
|
aprisaXEFXOEchoCanceller OBJECT-TYPE
|
|
SYNTAX INTEGER { fxoEchoCancellerOff (0),
|
|
fxoEchoCancellerOn (1),
|
|
fxoEchoCancellerAutoG164 (2),
|
|
fxoEchoCancellerAutoG165 (3),
|
|
fxoEchoCancellerReserved1 (4),
|
|
fxoEchoCancellerReserved2 (5),
|
|
fxoEchoCancellerReserved3 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the echo canceller to off, on or auto. The
|
|
reserved values are for internal use only and
|
|
cannot be set via SNMP."
|
|
::= { aprisaXEFXOControlTableEntry 20 }
|
|
|
|
aprisaXEFXOABitOffHook OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS A off hook bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXOControlTableEntry 21 }
|
|
|
|
-- ***************************************************************************
|
|
-- End FXO
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Backplane Connections
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEBackplaneConnectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEBackplaneConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of AprisaXE Cross connections."
|
|
::= { aprisaXEObjects 150 }
|
|
|
|
aprisaXEBackplaneConnectionTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEBackplaneConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table entries define a circuit carried ove a TDM bus."
|
|
INDEX { aprisaXEBackplaneConnectionID }
|
|
::= { aprisaXEBackplaneConnectionTable 1 }
|
|
|
|
AprisaXEBackplaneConnectionTableEntry ::= SEQUENCE {
|
|
aprisaXEBackplaneConnectionID INTEGER,
|
|
aprisaXEBackplaneTdmBus INTEGER,
|
|
aprisaXEBackplaneStartBitPos INTEGER,
|
|
aprisaXEBackplaneLength INTEGER,
|
|
aprisaXEBackplaneInterface INTEGER
|
|
}
|
|
|
|
aprisaXEBackplaneConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Handle to associate circuits with backplane connections."
|
|
::= { aprisaXEBackplaneConnectionTableEntry 1 }
|
|
|
|
aprisaXEBackplaneTdmBus OBJECT-TYPE
|
|
SYNTAX AprisaXETdmBus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TDM Bus to switch: busA - busD."
|
|
::= { aprisaXEBackplaneConnectionTableEntry 2 }
|
|
|
|
aprisaXEBackplaneStartBitPos OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Start bit position on the associated TDM bus (0 - 2047)."
|
|
DEFVAL { 0 }
|
|
::= { aprisaXEBackplaneConnectionTableEntry 3 }
|
|
|
|
aprisaXEBackplaneLength OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Number of bits to place on the backplane TDM bus (0 - 2047)."
|
|
DEFVAL { 0 }
|
|
::= { aprisaXEBackplaneConnectionTableEntry 4 }
|
|
|
|
aprisaXEBackplaneInterface OBJECT-TYPE
|
|
SYNTAX AprisaXEInterfaceCnxnType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit this backplane connection is carrying."
|
|
::= { aprisaXEBackplaneConnectionTableEntry 5 }
|
|
|
|
|
|
aprisaXEBackplaneControl OBJECT IDENTIFIER ::= { aprisaXEObjects 180 }
|
|
|
|
aprisaXEBackplaneControlConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The Backplane Connection ID to add or delete."
|
|
::= { aprisaXEBackplaneControl 1 }
|
|
|
|
aprisaXEBackplaneControlTdmBus OBJECT-TYPE
|
|
SYNTAX AprisaXETdmBus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "TDM Bus to switch: busA - busD."
|
|
::= { aprisaXEBackplaneControl 2 }
|
|
|
|
aprisaXEBackplaneControlStartBitPos OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Start bit position on the associated TDM bus (0 - 2047)."
|
|
DEFVAL { 0 }
|
|
::= { aprisaXEBackplaneControl 3 }
|
|
|
|
aprisaXEBackplaneControlLength OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2048)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Number of bits to place on the backplane TDM bus (0 - 2048)."
|
|
DEFVAL { 0 }
|
|
::= { aprisaXEBackplaneControl 4 }
|
|
|
|
aprisaXEBackplaneControlInterface OBJECT-TYPE
|
|
SYNTAX AprisaXEInterfaceCnxnType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The type of circuit this backplane connection is carrying."
|
|
::= { aprisaXEBackplaneControl 5 }
|
|
|
|
aprisaXEBackplaneControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
addCommand (1),
|
|
deleteCommand (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Command to send to act upon rows in the Backplane
|
|
Connection table."
|
|
::= { aprisaXEBackplaneControl 6 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Backplane Connections
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Aggregate Connections
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEAggregateConnectionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEAggregateConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Aggregated backplane connections used for
|
|
interfaces with further cross-connection capability."
|
|
::= { aprisaXEObjects 160 }
|
|
|
|
aprisaXEAggregateConnectionTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEAggregateConnectionTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
INDEX { aprisaXEAggregateBackplaneID,
|
|
aprisaXEAggregateInterfaceID,
|
|
aprisaXEAggregateStartBitPos
|
|
}
|
|
::= { aprisaXEAggregateConnectionTable 1 }
|
|
|
|
AprisaXEAggregateConnectionTableEntry ::= SEQUENCE {
|
|
aprisaXEAggregateBackplaneID Integer32,
|
|
aprisaXEAggregateInterfaceID Integer32,
|
|
aprisaXEAggregateStartBitPos INTEGER,
|
|
aprisaXEAggregateLength INTEGER,
|
|
aprisaXEAggregateOffset INTEGER,
|
|
aprisaXEAggregateE1Port INTEGER
|
|
}
|
|
|
|
aprisaXEAggregateBackplaneID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Backplane Connection identifier."
|
|
::= { aprisaXEAggregateConnectionTableEntry 1 }
|
|
|
|
aprisaXEAggregateInterfaceID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
::= { aprisaXEAggregateConnectionTableEntry 2 }
|
|
|
|
aprisaXEAggregateStartBitPos OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Start bit position of the data coming into the
|
|
cross-connection device (SWITI) for this interface connection."
|
|
::= { aprisaXEAggregateConnectionTableEntry 3 }
|
|
|
|
aprisaXEAggregateLength OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Number of bits required for this interface connection."
|
|
::= { aprisaXEAggregateConnectionTableEntry 4 }
|
|
|
|
aprisaXEAggregateOffset OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Offset into the aggregate connection where this
|
|
interface connection is placed."
|
|
::= { aprisaXEAggregateConnectionTableEntry 5 }
|
|
|
|
aprisaXEAggregateE1Port OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port number associated with this connection."
|
|
::= { aprisaXEAggregateConnectionTableEntry 6 }
|
|
|
|
|
|
aprisaXEAggregateControl OBJECT IDENTIFIER ::= { aprisaXEObjects 170 }
|
|
|
|
aprisaXEAggregateControlBackplaneID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The backplane ID to add or delete."
|
|
::= { aprisaXEAggregateControl 1 }
|
|
|
|
aprisaXEAggregateControlInterfaceID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Aggregate connection identifier."
|
|
::= { aprisaXEAggregateControl 2 }
|
|
|
|
aprisaXEAggregateControlStartBitPos OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Start bit position of the data coming into the
|
|
cross-connection device (SWITI) for this interface connection."
|
|
::= { aprisaXEAggregateControl 3 }
|
|
|
|
aprisaXEAggregateControlLength OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Number of bits required for this interface connection."
|
|
::= { aprisaXEAggregateControl 4 }
|
|
|
|
aprisaXEAggregateControlOffset OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2047)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Offset into the aggregate connection where this
|
|
interface connection is placed."
|
|
::= { aprisaXEAggregateControl 5 }
|
|
|
|
aprisaXEAggregateControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
addCommand (1),
|
|
deleteCommand (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Command to send to act upon the rows in the Aggregate
|
|
Connection table."
|
|
::= { aprisaXEAggregateControl 6 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Aggregate Connections
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Cross Connect Control
|
|
-- ***************************************************************************
|
|
|
|
aprisaXECrossConnectControl OBJECT IDENTIFIER ::= { aprisaXEObjects 200 }
|
|
|
|
aprisaXECrossConnectControlCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { noCommand (0),
|
|
deleteCommand (1),
|
|
activateCommand (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Command to send to delete all current cross-connections or
|
|
to activate a new set of cross-connections."
|
|
::= { aprisaXECrossConnectControl 1 }
|
|
|
|
aprisaXEMotherboardExtendedModeCapable OBJECT-TYPE
|
|
SYNTAX INTEGER { extModeNo (0),
|
|
extModeYes (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Allows the cross connect application to determine whether
|
|
to stripe cross connections or not."
|
|
::= { aprisaXECrossConnectControl 2 }
|
|
|
|
aprisaXEEthernetActivationStatus OBJECT-TYPE
|
|
SYNTAX AprisaXECCActivationStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Ethernet activation status i.e activated, failed or
|
|
currently busy activating."
|
|
::= { aprisaXECrossConnectControl 3 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Cross Connect Control
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Cross Connect Activation Status Table
|
|
-- ***************************************************************************
|
|
|
|
aprisaXECCActivationStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXECCActivationStatusTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "CC Activation status table."
|
|
::= { aprisaXEObjects 202 }
|
|
|
|
aprisaXECCActivationStatusTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXECCActivationStatusTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for CC Activation status table."
|
|
INDEX { aprisaXECCActivationStatusSlotIndex }
|
|
::= { aprisaXECCActivationStatusTable 1 }
|
|
|
|
AprisaXECCActivationStatusTableEntry ::= SEQUENCE {
|
|
aprisaXECCActivationStatusSlotIndex INTEGER,
|
|
aprisaXECCActivationStatus INTEGER
|
|
}
|
|
|
|
aprisaXECCActivationStatusSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for CC Activation Status table."
|
|
::= { aprisaXECCActivationStatusTableEntry 1 }
|
|
|
|
aprisaXECCActivationStatus OBJECT-TYPE
|
|
SYNTAX AprisaXECCActivationStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Cross-connect activation status i.e activated, failed or
|
|
currently busy activating."
|
|
::= { aprisaXECCActivationStatusTableEntry 2 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Cross Connect Activation Status Table
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- FXS
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEFXSPortControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEFXSPortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Port Control table for FXS."
|
|
::= { aprisaXEObjects 190 }
|
|
|
|
aprisaXEFXSPortControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSPortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for FXS table."
|
|
INDEX { aprisaXEFXSPortControlSlotIndex,
|
|
aprisaXEFXSPortIndex
|
|
}
|
|
::= { aprisaXEFXSPortControlTable 1 }
|
|
|
|
AprisaXEFXSPortControlTableEntry ::= SEQUENCE {
|
|
aprisaXEFXSPortControlSlotIndex INTEGER,
|
|
aprisaXEFXSPortIndex INTEGER,
|
|
aprisaXEFXSLoopback INTEGER,
|
|
aprisaXEFXSAdpcmCompression INTEGER,
|
|
aprisaXEFXSRxGain INTEGER,
|
|
aprisaXEFXSTxGain INTEGER,
|
|
aprisaXEFXSConnectionID INTEGER,
|
|
aprisaXEFXSSignallingConnectionID INTEGER,
|
|
aprisaXEFXSInputLevel INTEGER,
|
|
aprisaXEFXSOutputLevel INTEGER,
|
|
aprisaXEFXSPathMute INTEGER
|
|
}
|
|
|
|
aprisaXEFXSPortControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for FXS Control table."
|
|
::= { aprisaXEFXSPortControlTableEntry 1 }
|
|
|
|
aprisaXEFXSPortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port index for FXS Control table."
|
|
::= { aprisaXEFXSPortControlTableEntry 2 }
|
|
|
|
aprisaXEFXSLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Loopback control on or off for ports."
|
|
::= { aprisaXEFXSPortControlTableEntry 3 }
|
|
|
|
aprisaXEFXSAdpcmCompression OBJECT-TYPE
|
|
SYNTAX AprisaXEAdpcmCompression
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "ADPCM compression 16, 24, 32, 64 kbps or none."
|
|
DEFVAL { none }
|
|
::= { aprisaXEFXSPortControlTableEntry 4 }
|
|
|
|
aprisaXEFXSRxGain OBJECT-TYPE
|
|
SYNTAX INTEGER { fxsrxpos30 (0),
|
|
fxsrxpos25 (1),
|
|
fxsrxpos20 (2),
|
|
fxsrxpos15 (3),
|
|
fxsrxpos10 (4),
|
|
fxsrxpos05 (5),
|
|
fxsrxpos0 (6),
|
|
fxsrxneg05 (7),
|
|
fxsrxneg10 (8),
|
|
fxsrxneg15 (9),
|
|
fxsrxneg20 (10),
|
|
fxsrxneg25 (11),
|
|
fxsrxneg30 (12),
|
|
fxsrxneg35 (13),
|
|
fxsrxneg40 (14),
|
|
fxsrxneg45 (15),
|
|
fxsrxneg50 (16),
|
|
fxsrxneg55 (17),
|
|
fxsrxneg60 (18),
|
|
fxsrxneg65 (19),
|
|
fxsrxneg70 (20),
|
|
fxsrxneg75 (21),
|
|
fxsrxneg80 (22),
|
|
fxsrxneg85 (23),
|
|
fxsrxneg90 (24),
|
|
fxsrxneg95 (25)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Rx gain -9.5 dB to +3 dB in 0.5 dB steps."
|
|
::= { aprisaXEFXSPortControlTableEntry 5 }
|
|
|
|
aprisaXEFXSTxGain OBJECT-TYPE
|
|
SYNTAX INTEGER { fxstxpos95 (0),
|
|
fxstxpos90 (1),
|
|
fxstxpos85 (2),
|
|
fxstxpos80 (3),
|
|
fxstxpos75 (4),
|
|
fxstxpos70 (5),
|
|
fxstxpos65 (6),
|
|
fxstxpos60 (7),
|
|
fxstxpos55 (8),
|
|
fxstxpos50 (9),
|
|
fxstxpos45 (10),
|
|
fxstxpos40 (11),
|
|
fxstxpos35 (12),
|
|
fxstxpos30 (13),
|
|
fxstxpos25 (14),
|
|
fxstxpos20 (15),
|
|
fxstxpos15 (16),
|
|
fxstxpos10 (17),
|
|
fxstxpos05 (18),
|
|
fxstxpos0 (19),
|
|
fxstxneg05 (20),
|
|
fxstxneg10 (21),
|
|
fxstxneg15 (22),
|
|
fxstxneg20 (23),
|
|
fxstxneg25 (24),
|
|
fxstxneg30 (25)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Tx gain -3 dB to 9.5 dB in 0.5 dB steps."
|
|
::= { aprisaXEFXSPortControlTableEntry 6 }
|
|
|
|
aprisaXEFXSConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated cross-connect Backplane Connection ID."
|
|
::= { aprisaXEFXSPortControlTableEntry 7 }
|
|
|
|
aprisaXEFXSSignallingConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated signalling cross-connect Backplane Connection ID."
|
|
::= { aprisaXEFXSPortControlTableEntry 8 }
|
|
|
|
aprisaXEFXSInputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSInputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Input Level -9.0 dBr to +3.0 dBr in half dB steps."
|
|
::= { aprisaXEFXSPortControlTableEntry 9 }
|
|
|
|
aprisaXEFXSOutputLevel OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSOutputLevel
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Output Level -9.5 dBr to +2.5 dBr in 0.5 dB steps."
|
|
::= { aprisaXEFXSPortControlTableEntry 10 }
|
|
|
|
aprisaXEFXSPathMute OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSPathMute
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Applies DFXS Mute Function - No Mute, Mute Rx or Mute Tx."
|
|
::= { aprisaXEFXSPortControlTableEntry 11 }
|
|
|
|
--
|
|
-- end of table
|
|
--
|
|
|
|
aprisaXEFXSControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEFXSControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Control table for FXS."
|
|
::= { aprisaXEObjects 195 }
|
|
|
|
aprisaXEFXSControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEFXSControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for FXS table."
|
|
INDEX { aprisaXEFXSControlSlotIndex }
|
|
::= { aprisaXEFXSControlTable 1 }
|
|
|
|
AprisaXEFXSControlTableEntry ::= SEQUENCE {
|
|
aprisaXEFXSControlSlotIndex INTEGER,
|
|
aprisaXEFXSPCMLaw INTEGER,
|
|
aprisaXEFXSEchoCanceller INTEGER,
|
|
aprisaXEFXSBillingToneFrequency INTEGER,
|
|
aprisaXEFXSBillingToneAmplitude INTEGER,
|
|
aprisaXEFXSBillingToneDecay INTEGER,
|
|
aprisaXEFXSRingerFrequency INTEGER,
|
|
aprisaXEFXSRingerAmplitude INTEGER,
|
|
aprisaXEFXSLineImpedance INTEGER,
|
|
aprisaXEFXSCasMode INTEGER,
|
|
aprisaXEFXSCasSignal INTEGER,
|
|
aprisaXEFXSTransHybridBalance INTEGER,
|
|
aprisaXEFXSLineReversal INTEGER,
|
|
aprisaXEFXSCalibrate INTEGER,
|
|
aprisaXEFXSABitFault INTEGER,
|
|
aprisaXEFXSBBitRing INTEGER,
|
|
aprisaXEFXSCBitBilling INTEGER,
|
|
aprisaXEFXSDBitReversals INTEGER,
|
|
aprisaXEFXSLoopParameters INTEGER,
|
|
aprisaXEFXSABitOffHook INTEGER
|
|
}
|
|
|
|
aprisaXEFXSControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for FXS Control table."
|
|
::= { aprisaXEFXSControlTableEntry 1 }
|
|
|
|
aprisaXEFXSPCMLaw OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmLaw
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the PCM law to A-law or u-law."
|
|
::= { aprisaXEFXSControlTableEntry 2 }
|
|
|
|
aprisaXEFXSEchoCanceller OBJECT-TYPE
|
|
SYNTAX INTEGER { echoCancellerOff (0),
|
|
echoCancellerOn (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the echo canceller to on or off."
|
|
::= { aprisaXEFXSControlTableEntry 3 }
|
|
|
|
aprisaXEFXSBillingToneFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER { khz12 (0),
|
|
khz16 (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the billing tone generator frequency to 12kHz or 16kHz."
|
|
::= { aprisaXEFXSControlTableEntry 4 }
|
|
|
|
aprisaXEFXSBillingToneAmplitude OBJECT-TYPE
|
|
SYNTAX INTEGER { mv400 (6),
|
|
mv300 (0),
|
|
mv250 (1),
|
|
mv200 (2),
|
|
mv150 (3),
|
|
mv100 (4),
|
|
mv50 (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the billing tone generator amplitude to 400mV, 300mV,
|
|
250mV, 200mV, 150mV, 100mV or 50mV. Note, that software
|
|
release 7.3.x only supports 400mV, 300mV, 200mV and 100mV."
|
|
::= { aprisaXEFXSControlTableEntry 5 }
|
|
|
|
aprisaXEFXSBillingToneDecay OBJECT-TYPE
|
|
SYNTAX INTEGER { ms02 (0),
|
|
ms05 (1),
|
|
ms1 (2),
|
|
ms2 (3),
|
|
ms5 (4),
|
|
ms10 (5),
|
|
ms20 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the billing tone generator attack decay ramp
|
|
to 0.2ms, 0.5ms, 1ms, 2ms, 5ms, 10ms or 20ms."
|
|
::= { aprisaXEFXSControlTableEntry 6 }
|
|
|
|
aprisaXEFXSRingerFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER { hz17 (0),
|
|
hz25 (1),
|
|
hz50 (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the ringer frequency to 17Hz, 25Hz or 50Hz."
|
|
::= { aprisaXEFXSControlTableEntry 7 }
|
|
|
|
aprisaXEFXSRingerAmplitude OBJECT-TYPE
|
|
SYNTAX INTEGER { vrms40 (0),
|
|
vrms45 (1),
|
|
vrms50 (2),
|
|
vrms55 (3),
|
|
vrms60 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the ringer amplitude to 40 V RMS, 45 V RMS,
|
|
50 V RMS, 55 V RMS or 60 V RMS."
|
|
::= { aprisaXEFXSControlTableEntry 8 }
|
|
|
|
aprisaXEFXSLineImpedance OBJECT-TYPE
|
|
SYNTAX INTEGER { lineImpd1 (0),
|
|
lineImpd2 (1),
|
|
lineImpd3 (2),
|
|
lineImpd4 (3),
|
|
lineImpd5 (4),
|
|
lineImpd6 (5),
|
|
lineImpd7 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the subscriber line impedance to 600 Ohms, 900 Ohms,
|
|
600 Ohms + 2.16 uF, 900 Ohms + 2.16 uF,
|
|
TN12 - 220 Ohms + (820 Ohms || 120 nF),
|
|
TBR21 - 270 Ohms + (750 Ohms || 150 nF),
|
|
BT3 - 370 Ohms + (620 Ohms || 310 nF)"
|
|
::= { aprisaXEFXSControlTableEntry 9 }
|
|
|
|
aprisaXEFXSCasMode OBJECT-TYPE
|
|
SYNTAX INTEGER { casxe (0),
|
|
casse (1),
|
|
cas4w (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS mode to XE,SE or 4Wire compatible."
|
|
::= { aprisaXEFXSControlTableEntry 10 }
|
|
|
|
aprisaXEFXSCasSignal OBJECT-TYPE
|
|
SYNTAX AprisaXESignalState
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Set the CAS signal to normal or invert."
|
|
::= { aprisaXEFXSControlTableEntry 11 }
|
|
|
|
aprisaXEFXSTransHybridBalance OBJECT-TYPE
|
|
SYNTAX INTEGER { transHybridBal1 (0),
|
|
transHybridBal2 (1),
|
|
transHybridBal3 (2),
|
|
transHybridBal4 (3),
|
|
transHybridBal5 (4),
|
|
transHybridBal6 (5),
|
|
transHybridBal7 (6),
|
|
transHybridBal8 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the trans hybrid balance to 4.08dB, 2.5dB,
|
|
1.16dB, 0dB, -1.02dB, -1.94dB, -2.77dB, Off"
|
|
::= { aprisaXEFXSControlTableEntry 12 }
|
|
|
|
aprisaXEFXSLineReversal OBJECT-TYPE
|
|
SYNTAX INTEGER { fxsLineRevOn (0),
|
|
fxsLineRevOff (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Set the line reversal on/off."
|
|
::= { aprisaXEFXSControlTableEntry 13 }
|
|
|
|
aprisaXEFXSCalibrate OBJECT-TYPE
|
|
SYNTAX INTEGER { fxsCalibrateNo (0),
|
|
fxsCalibrateYes (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Recalibrate the card yes/no."
|
|
::= { aprisaXEFXSControlTableEntry 14 }
|
|
|
|
aprisaXEFXSABitFault OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS A fault bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXSControlTableEntry 15 }
|
|
|
|
aprisaXEFXSBBitRing OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS B ring bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXSControlTableEntry 16 }
|
|
|
|
aprisaXEFXSCBitBilling OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS C billing bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXSControlTableEntry 17 }
|
|
|
|
aprisaXEFXSDBitReversals OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS D reversals bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXSControlTableEntry 18 }
|
|
|
|
aprisaXEFXSLoopParameters OBJECT-TYPE
|
|
SYNTAX INTEGER { fxsLoopParamDefault (0),
|
|
fxsLoopParamTelkomSA (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the loop parameters to 'default' or 'Telkom SA Limited'."
|
|
::= { aprisaXEFXSControlTableEntry 19 }
|
|
|
|
aprisaXEFXSABitOffHook OBJECT-TYPE
|
|
SYNTAX AprisaXE2WireSignalState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Set the CAS A off hook bit to
|
|
Transparent Normal, Transparent Inverted,
|
|
Forced Normal or Forced Inverted."
|
|
::= { aprisaXEFXSControlTableEntry 20 }
|
|
|
|
-- ***************************************************************************
|
|
-- End FXS
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- HSS
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEHSSControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEHSSControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Control table for HSS."
|
|
::= { aprisaXEObjects 207 }
|
|
|
|
aprisaXEHSSControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEHSSControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for HSS table."
|
|
INDEX { aprisaXEHSSControlSlotIndex }
|
|
::= { aprisaXEHSSControlTable 1 }
|
|
|
|
AprisaXEHSSControlTableEntry ::= SEQUENCE {
|
|
aprisaXEHSSControlSlotIndex INTEGER,
|
|
aprisaXEHSSConnectionID INTEGER,
|
|
aprisaXEHSSSignallingID INTEGER,
|
|
aprisaXEHSSEquipmentMode INTEGER,
|
|
aprisaXEHSSLoopback INTEGER,
|
|
aprisaXEHSSNetworkClockSource INTEGER,
|
|
aprisaXEHSSSerialBaudRate INTEGER,
|
|
aprisaXEHSSV110BaudRate INTEGER,
|
|
aprisaXEHSSSendHandshakingMode INTEGER,
|
|
aprisaXEHSSDataReadyMode INTEGER,
|
|
aprisaXEHSSCarrierDetectMode INTEGER,
|
|
aprisaXEHSSClockSelection INTEGER,
|
|
aprisaXEHSSXTxCEnabled INTEGER,
|
|
aprisaXEHSSSerialMode INTEGER
|
|
}
|
|
|
|
aprisaXEHSSControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for HSS Control Table."
|
|
::= { aprisaXEHSSControlTableEntry 1 }
|
|
|
|
aprisaXEHSSConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Backplane Connection ID for data connection."
|
|
::= { aprisaXEHSSControlTableEntry 2 }
|
|
|
|
aprisaXEHSSSignallingID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Backplane connection ID for signalling/control connection."
|
|
::= { aprisaXEHSSControlTableEntry 3 }
|
|
|
|
aprisaXEHSSEquipmentMode OBJECT-TYPE
|
|
SYNTAX AprisaXESerialEquipmentMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Terminal Equipment mode, DCE or DTE, this is a direct reflection
|
|
of the equipment mode based on the type of cable currently
|
|
connected. The value is not defined if no cable is attached."
|
|
::= { aprisaXEHSSControlTableEntry 4 }
|
|
|
|
aprisaXEHSSLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Interface loopback control."
|
|
DEFVAL { 0 }
|
|
::= { aprisaXEHSSControlTableEntry 5 }
|
|
|
|
aprisaXEHSSNetworkClockSource OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockSelect
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls whether the port drive the clock source or not."
|
|
::= { aprisaXEHSSControlTableEntry 6 }
|
|
|
|
aprisaXEHSSSerialBaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER (1..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Serial Baud rate where 1 = 8kbps and 256 = 2Mbps."
|
|
::= { aprisaXEHSSControlTableEntry 7 }
|
|
|
|
aprisaXEHSSV110BaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER { v110-600 (0),
|
|
v110-1200 (1),
|
|
v110-2400 (2),
|
|
v110-4800 (3),
|
|
v110-7200 (4),
|
|
v110-9600 (5),
|
|
v110-12000 (6),
|
|
v110-14400 (7),
|
|
v110-19200 (8),
|
|
v110-24000 (9),
|
|
v110-28800 (10),
|
|
v110-38400 (11)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "V110 baud rate."
|
|
::= { aprisaXEHSSControlTableEntry 8 }
|
|
|
|
aprisaXEHSSSendHandshakingMode OBJECT-TYPE
|
|
SYNTAX INTEGER { rts-ctsOff (0),
|
|
rts-ctsOn (1),
|
|
rts-ctsCarrier (2),
|
|
rts-ctsCarrierRemote (3),
|
|
rts-ctsCarrierLocalDCD (4),
|
|
rts-ctsCarrierLocalRTS (5),
|
|
rts-ctsCarrierLocalRTS1ms (6),
|
|
rts-ctsCarrierLocalRTS24ms (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select 1 of 8 RTS/CTS modes of operation."
|
|
::= { aprisaXEHSSControlTableEntry 9 }
|
|
|
|
aprisaXEHSSDataReadyMode OBJECT-TYPE
|
|
SYNTAX INTEGER { dsr-dtrOff (0),
|
|
dsr-dtrOn (1),
|
|
dsr-dtrCarrier (2),
|
|
dsr-dtrCarrierRemote (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select 1 of 8 DSR/DTR modes."
|
|
::= { aprisaXEHSSControlTableEntry 10 }
|
|
|
|
aprisaXEHSSCarrierDetectMode OBJECT-TYPE
|
|
SYNTAX INTEGER { dcdOff (0),
|
|
dcdOn (1),
|
|
dcdCarrierRemoteDCD (2),
|
|
dcdCarrierLocalDTR (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select 1 of 4 DCD modes."
|
|
::= { aprisaXEHSSControlTableEntry 11 }
|
|
|
|
aprisaXEHSSClockSelection OBJECT-TYPE
|
|
SYNTAX INTEGER { hssClockInternal (0),
|
|
hssClockXTxC (1),
|
|
hssClockTxC (2),
|
|
hssClockOverhead (3),
|
|
hssClockNoOverhead (4),
|
|
hssClockXTxC-RxC (5),
|
|
hssClockXTxCNoOverhead (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select the clock mode internal to the HSS traffic path."
|
|
::= { aprisaXEHSSControlTableEntry 12 }
|
|
|
|
aprisaXEHSSXTxCEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER { hssxTxCEnabled (0),
|
|
hssxTxCDisabled (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Select whether XTxC generation is enabled or disabled for
|
|
the port. The default is enabled."
|
|
::= { aprisaXEHSSControlTableEntry 13 }
|
|
|
|
aprisaXEHSSSerialMode OBJECT-TYPE
|
|
SYNTAX AprisaXEHssSerialMode
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the type of serial interface cable is connected to
|
|
the HSS port."
|
|
::= { aprisaXEHSSControlTableEntry 14 }
|
|
|
|
-- ***************************************************************************
|
|
-- End HSS
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- V24
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEV24PortControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEV24PortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Port Control table for V24."
|
|
::= { aprisaXEObjects 210 }
|
|
|
|
aprisaXEV24PortControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEV24PortControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for V24 table."
|
|
INDEX { aprisaXEV24PortControlSlotIndex,
|
|
aprisaXEV24PortIndex
|
|
}
|
|
::= { aprisaXEV24PortControlTable 1 }
|
|
|
|
AprisaXEV24PortControlTableEntry ::= SEQUENCE {
|
|
aprisaXEV24PortControlSlotIndex INTEGER,
|
|
aprisaXEV24PortIndex INTEGER,
|
|
aprisaXEV24BaudRate INTEGER,
|
|
aprisaXEV24Loopback INTEGER,
|
|
aprisaXEV24DataBits INTEGER,
|
|
aprisaXEV24StopBits INTEGER,
|
|
aprisaXEV24ParityBits INTEGER,
|
|
aprisaXEV24ConnectionID INTEGER
|
|
}
|
|
|
|
aprisaXEV24PortControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for V24 Control table."
|
|
::= { aprisaXEV24PortControlTableEntry 1 }
|
|
|
|
aprisaXEV24PortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port index for V24 Control table."
|
|
::= { aprisaXEV24PortControlTableEntry 2 }
|
|
|
|
aprisaXEV24BaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER { v24-300 (0),
|
|
v24-600 (1),
|
|
v24-1200 (2),
|
|
v24-2400 (3),
|
|
v24-4800 (4),
|
|
v24-7200 (5),
|
|
v24-9600 (6),
|
|
v24-12800 (7),
|
|
v24-14400 (8),
|
|
v24-19200 (9),
|
|
v24-23040 (10),
|
|
v24-28800 (11),
|
|
v24-38400 (12),
|
|
v24-57600 (13),
|
|
v24-115200 (14)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Baud Rate from 300 baud to 115200 baud."
|
|
DEFVAL { none }
|
|
::= { aprisaXEV24PortControlTableEntry 3 }
|
|
|
|
aprisaXEV24Loopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Loopback control on or off for ports."
|
|
::= { aprisaXEV24PortControlTableEntry 4 }
|
|
|
|
aprisaXEV24DataBits OBJECT-TYPE
|
|
SYNTAX INTEGER { databits7 (0),
|
|
databits8 (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "No of data bits used, 7 or 8."
|
|
::= { aprisaXEV24PortControlTableEntry 5 }
|
|
|
|
aprisaXEV24StopBits OBJECT-TYPE
|
|
SYNTAX INTEGER { stopbits1 (0),
|
|
stopbits2 (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "No of stop bits used, 1 or 2."
|
|
::= { aprisaXEV24PortControlTableEntry 6 }
|
|
|
|
aprisaXEV24ParityBits OBJECT-TYPE
|
|
SYNTAX INTEGER { paritybits0 (0),
|
|
paritybits1 (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "No of parity bits used, 0 or 1."
|
|
::= { aprisaXEV24PortControlTableEntry 7 }
|
|
|
|
aprisaXEV24ConnectionID OBJECT-TYPE
|
|
SYNTAX AprisaXEConnectionID
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Associated cross-connect Backplane Connection ID."
|
|
::= { aprisaXEV24PortControlTableEntry 8 }
|
|
|
|
-- ***************************************************************************
|
|
-- End V24
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Upgrade Control
|
|
--
|
|
-- Software upgrade (using TFTP) can be performed by setting the required
|
|
-- software version string and setting the command OID. This results in a
|
|
-- file being uploaded from the server release_x_y_z.cfg. This file lists the
|
|
-- files required for the specified software release. TFTP is then used to
|
|
-- upload any files not currently installed and the required images are
|
|
-- activated.
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXESoftwareUpgradeControl OBJECT IDENTIFIER ::= { aprisaXEObjects 300 }
|
|
|
|
aprisaXESoftwareUpgradeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..16) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "New software version details of the form x_y_z."
|
|
::= { aprisaXESoftwareUpgradeControl 1 }
|
|
|
|
aprisaXESoftwareUpgradeCommand OBJECT-TYPE
|
|
SYNTAX INTEGER { none (0),
|
|
upgrade (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Command used to instigate a software upgrade."
|
|
::= { aprisaXESoftwareUpgradeControl 2 }
|
|
|
|
aprisaXESoftwareUpgradeResult OBJECT-TYPE
|
|
SYNTAX FourRFProcessResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of a software upgrade, this will have to be polled to
|
|
follow the upload progress."
|
|
::= { aprisaXESoftwareUpgradeControl 3 }
|
|
|
|
aprisaXESoftwareUpgradeControlGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXESoftwareUpgradeVersion,
|
|
aprisaXESoftwareUpgradeCommand,
|
|
aprisaXESoftwareUpgradeResult
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The Aprisa XE software upgrade group."
|
|
::= { aprisaXEGroups 300 }
|
|
|
|
-- ***************************************************************************
|
|
-- End Upgrade Control
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Ethernet Table
|
|
--
|
|
-- A table which maintains the VLAN and QOS configuration of each of
|
|
-- the User Ethernet Ports
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEEthernetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEEthernetTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table used to display and configure Ethernet settings."
|
|
::= { aprisaXEObjects 97 }
|
|
|
|
aprisaXEEthernetTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Individual Ethernet port settings."
|
|
INDEX { aprisaXEEthernetPortNum }
|
|
::= { aprisaXEEthernetTable 1 }
|
|
|
|
AprisaXEEthernetTableEntry ::= SEQUENCE {
|
|
aprisaXEEthernetPortNum INTEGER,
|
|
aprisaXEEthernetGroup INTEGER,
|
|
aprisaXEEthernetIngressRate INTEGER,
|
|
aprisaXEEthernetPortPriority INTEGER
|
|
}
|
|
|
|
aprisaXEEthernetPortNum OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The port number, there are four ports on the hub."
|
|
::= { aprisaXEEthernetTableEntry 1 }
|
|
|
|
aprisaXEEthernetGroup OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetGroup
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The Ethernet Group of which this port is a member."
|
|
::= { aprisaXEEthernetTableEntry 2 }
|
|
|
|
aprisaXEEthernetIngressRate OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetFrameRate
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The ingress frame rate limit for this port."
|
|
::= { aprisaXEEthernetTableEntry 3 }
|
|
|
|
aprisaXEEthernetPortPriority OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetPortPriority
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the bandwidth allocated to this port."
|
|
::= { aprisaXEEthernetTableEntry 4 }
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Ethernet Settings
|
|
--
|
|
-- The global VLAN and QOS configuration of the Ethernet Switch
|
|
--
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEEthernetVlanQosSettings OBJECT IDENTIFIER ::= { aprisaXEObjects 98 }
|
|
|
|
aprisaXEEthernetGrouping OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetGrouping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates whether Ethernet grouping (VLANs) is enabled or disabled."
|
|
::= { aprisaXEEthernetVlanQosSettings 1 }
|
|
|
|
aprisaXEEthernetManagementGroup OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetGroup
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The Ethernet Group for management."
|
|
::= { aprisaXEEthernetVlanQosSettings 2 }
|
|
|
|
aprisaXEEthernetPrioQueueScheduling OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetPrioQueueScheduling
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates Ethernet priority queue scheduling scheme (either strict or weighted)."
|
|
::= { aprisaXEEthernetVlanQosSettings 3 }
|
|
|
|
aprisaXEEthernetPrioQueueMapping OBJECT-TYPE
|
|
SYNTAX AprisaXEEthernetPrioQueueMapping
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the IEEE 802.1 Ethernet priority queue mapping scheme (either standard or cisco)."
|
|
::= { aprisaXEEthernetVlanQosSettings 4 }
|
|
|
|
aprisaXEDefaultEthernetGrouping OBJECT-TYPE
|
|
SYNTAX AprisaXEDefaultAction
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates when Ethernet Grouping settings must be reset to default values."
|
|
::= { aprisaXEEthernetVlanQosSettings 5 }
|
|
|
|
aprisaXEDefaultEthernetQos OBJECT-TYPE
|
|
SYNTAX AprisaXEDefaultAction
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates when Ethernet Grouping settings must be reset to default values."
|
|
::= { aprisaXEEthernetVlanQosSettings 6 }
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Dual E1 Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEDualJetBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEDualJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Dual E1 card specific configuration details."
|
|
::= { aprisaXEObjects 220 }
|
|
|
|
aprisaXEDualJetBoardEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEDualJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Dual E1 configuration details."
|
|
INDEX { aprisaXEDualJetBoardTableIndex }
|
|
::= { aprisaXEDualJetBoardTable 1 }
|
|
|
|
AprisaXEDualJetBoardEntry ::= SEQUENCE {
|
|
aprisaXEDualJetBoardTableIndex INTEGER
|
|
}
|
|
|
|
aprisaXEDualJetBoardTableIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Dual E1 board indexed by slot."
|
|
::= { aprisaXEDualJetBoardEntry 1 }
|
|
|
|
aprisaXEDualJetPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEDualJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table based on slot and port of DualJet cards alarms."
|
|
::= { aprisaXEObjects 221 }
|
|
|
|
aprisaXEDualJetPortEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEDualJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Dual E1 port alarms."
|
|
INDEX { aprisaXEDualJetPortTableSlot,
|
|
aprisaXEDualJetPortTablePort
|
|
}
|
|
::= { aprisaXEDualJetPortTable 1 }
|
|
|
|
AprisaXEDualJetPortEntry ::= SEQUENCE {
|
|
aprisaXEDualJetPortTableSlot INTEGER,
|
|
aprisaXEDualJetPortTablePort INTEGER,
|
|
aprisaXEDualJetAISAlarmStatus INTEGER,
|
|
aprisaXEDualJetAISAlarmSeverity INTEGER,
|
|
aprisaXEDualJetAISAlarmEnabled INTEGER,
|
|
aprisaXEDualJetLOSAlarmStatus INTEGER,
|
|
aprisaXEDualJetLOSAlarmSeverity INTEGER,
|
|
aprisaXEDualJetLOSAlarmEnabled INTEGER
|
|
}
|
|
|
|
aprisaXEDualJetPortTableSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on slot number."
|
|
::= { aprisaXEDualJetPortEntry 1 }
|
|
|
|
aprisaXEDualJetPortTablePort OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on port number."
|
|
::= { aprisaXEDualJetPortEntry 2 }
|
|
|
|
aprisaXEDualJetAISAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm status."
|
|
::= { aprisaXEDualJetPortEntry 3 }
|
|
|
|
aprisaXEDualJetAISAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm severity."
|
|
::= { aprisaXEDualJetPortEntry 4 }
|
|
|
|
aprisaXEDualJetAISAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm enabled or disabled."
|
|
::= { aprisaXEDualJetPortEntry 5 }
|
|
|
|
aprisaXEDualJetLOSAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm status."
|
|
::= { aprisaXEDualJetPortEntry 6 }
|
|
|
|
aprisaXEDualJetLOSAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm severity."
|
|
::= { aprisaXEDualJetPortEntry 7 }
|
|
|
|
aprisaXEDualJetLOSAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm enabled or disabled."
|
|
::= { aprisaXEDualJetPortEntry 8 }
|
|
|
|
aprisaXEDualJetIFConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEDualJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Switch data table which describes the
|
|
allocation of user data on to the TDM busses."
|
|
::= { aprisaXEObjects 222 }
|
|
|
|
aprisaXEDualJetIFConfigEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEDualJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Dual JET config data."
|
|
INDEX { aprisaXEDualJetIFConfigSlotIndex,
|
|
aprisaXEDualJetIFConfigPortIndex
|
|
}
|
|
::= { aprisaXEDualJetIFConfigTable 1 }
|
|
|
|
AprisaXEDualJetIFConfigEntry ::= SEQUENCE {
|
|
aprisaXEDualJetIFConfigSlotIndex INTEGER,
|
|
aprisaXEDualJetIFConfigPortIndex INTEGER,
|
|
aprisaXEDualJetTrafficType INTEGER,
|
|
aprisaXEDualJetLoopback INTEGER,
|
|
aprisaXEDualJetLineEncoding INTEGER,
|
|
aprisaXEDualJetPcmMode INTEGER,
|
|
aprisaXEDualJetClockSource INTEGER,
|
|
aprisaXEDualJetLineRadioLoopback INTEGER,
|
|
aprisaXEDualJetTxWaveFormShaper INTEGER
|
|
}
|
|
|
|
aprisaXEDualJetIFConfigSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXEDualJetIFConfigEntry 1 }
|
|
|
|
aprisaXEDualJetIFConfigPortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXEDualJetIFConfigEntry 2 }
|
|
|
|
aprisaXEDualJetTrafficType OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetTrafficType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the traffic type on a Dual JET port."
|
|
::= { aprisaXEDualJetIFConfigEntry 3 }
|
|
|
|
aprisaXEDualJetLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Controls the traffic loopback on a Dual JET port."
|
|
::= { aprisaXEDualJetIFConfigEntry 4 }
|
|
|
|
aprisaXEDualJetLineEncoding OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLineEncoding
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the line encoding, the default is
|
|
HDB3 for E1, B8ZS for T1."
|
|
::= { aprisaXEDualJetIFConfigEntry 5 }
|
|
|
|
aprisaXEDualJetPcmMode OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C."
|
|
::= { aprisaXEDualJetIFConfigEntry 6 }
|
|
|
|
aprisaXEDualJetClockSource OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockSelect
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls whether the port drives the clock soure or not."
|
|
::= { aprisaXEDualJetIFConfigEntry 7 }
|
|
|
|
aprisaXEDualJetLineRadioLoopback OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLoopbacks
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the E1 loopback setting on a port;
|
|
OFF, Line or Radio Facing."
|
|
::= { aprisaXEDualJetIFConfigEntry 8 }
|
|
|
|
aprisaXEDualJetTxWaveFormShaper OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetWaveFormShapers
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port;
|
|
0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft."
|
|
::= { aprisaXEDualJetIFConfigEntry 9 }
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- End Dual JET
|
|
-- ***************************************************************************
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- Single E1 Alarms
|
|
-- ***************************************************************************
|
|
|
|
aprisaXESingleJetBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXESingleJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Single E1 card specific configuration details."
|
|
::= { aprisaXEObjects 225 }
|
|
|
|
aprisaXESingleJetBoardEntry OBJECT-TYPE
|
|
SYNTAX AprisaXESingleJetBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Single E1 configuration details."
|
|
INDEX { aprisaXESingleJetBoardTableIndex }
|
|
::= { aprisaXESingleJetBoardTable 1 }
|
|
|
|
AprisaXESingleJetBoardEntry ::= SEQUENCE {
|
|
aprisaXESingleJetBoardTableIndex INTEGER
|
|
}
|
|
|
|
aprisaXESingleJetBoardTableIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Single E1 board indexed by slot."
|
|
::= { aprisaXESingleJetBoardEntry 1 }
|
|
|
|
aprisaXESingleJetPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXESingleJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table based on slot and port of SingleJet cards alarms."
|
|
::= { aprisaXEObjects 226 }
|
|
|
|
aprisaXESingleJetPortEntry OBJECT-TYPE
|
|
SYNTAX AprisaXESingleJetPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Single E1 port alarms."
|
|
INDEX { aprisaXESingleJetPortTableSlot,
|
|
aprisaXESingleJetPortTablePort
|
|
}
|
|
::= { aprisaXESingleJetPortTable 1 }
|
|
|
|
AprisaXESingleJetPortEntry ::= SEQUENCE {
|
|
aprisaXESingleJetPortTableSlot INTEGER,
|
|
aprisaXESingleJetPortTablePort INTEGER,
|
|
aprisaXESingleJetAISAlarmStatus INTEGER,
|
|
aprisaXESingleJetAISAlarmSeverity INTEGER,
|
|
aprisaXESingleJetAISAlarmEnabled INTEGER,
|
|
aprisaXESingleJetLOSAlarmStatus INTEGER,
|
|
aprisaXESingleJetLOSAlarmSeverity INTEGER,
|
|
aprisaXESingleJetLOSAlarmEnabled INTEGER
|
|
}
|
|
|
|
aprisaXESingleJetPortTableSlot OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on slot number."
|
|
::= { aprisaXESingleJetPortEntry 1 }
|
|
|
|
aprisaXESingleJetPortTablePort OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Port table index based on port number."
|
|
::= { aprisaXESingleJetPortEntry 2 }
|
|
|
|
aprisaXESingleJetAISAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm status."
|
|
::= { aprisaXESingleJetPortEntry 3 }
|
|
|
|
aprisaXESingleJetAISAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm severity."
|
|
::= { aprisaXESingleJetPortEntry 4 }
|
|
|
|
aprisaXESingleJetAISAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "AIS alarm enabled or disabled."
|
|
::= { aprisaXESingleJetPortEntry 5 }
|
|
|
|
aprisaXESingleJetLOSAlarmStatus OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm status."
|
|
::= { aprisaXESingleJetPortEntry 6 }
|
|
|
|
aprisaXESingleJetLOSAlarmSeverity OBJECT-TYPE
|
|
SYNTAX FourRFAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm severity."
|
|
::= { aprisaXESingleJetPortEntry 7 }
|
|
|
|
aprisaXESingleJetLOSAlarmEnabled OBJECT-TYPE
|
|
SYNTAX FourRFAlarmEnabled
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LOS alarm enabled or disabled."
|
|
::= { aprisaXESingleJetPortEntry 8 }
|
|
|
|
aprisaXESingleJetIFConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXESingleJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Switch data table which describes the
|
|
allocation of user data on to the TDM busses."
|
|
::= { aprisaXEObjects 227 }
|
|
|
|
aprisaXESingleJetIFConfigEntry OBJECT-TYPE
|
|
SYNTAX AprisaXESingleJetIFConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Single JET config data."
|
|
INDEX { aprisaXESingleJetIFConfigSlotIndex,
|
|
aprisaXESingleJetIFConfigPortIndex
|
|
}
|
|
::= { aprisaXESingleJetIFConfigTable 1 }
|
|
|
|
AprisaXESingleJetIFConfigEntry ::= SEQUENCE {
|
|
aprisaXESingleJetIFConfigSlotIndex INTEGER,
|
|
aprisaXESingleJetIFConfigPortIndex INTEGER,
|
|
aprisaXESingleJetTrafficType INTEGER,
|
|
aprisaXESingleJetLoopback INTEGER,
|
|
aprisaXESingleJetLineEncoding INTEGER,
|
|
aprisaXESingleJetPcmMode INTEGER,
|
|
aprisaXESingleJetClockSource INTEGER,
|
|
aprisaXESingleJetLineRadioLoopback INTEGER,
|
|
aprisaXESingleJetTxWaveFormShaper INTEGER
|
|
}
|
|
|
|
aprisaXESingleJetIFConfigSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXESingleJetIFConfigEntry 1 }
|
|
|
|
aprisaXESingleJetIFConfigPortIndex OBJECT-TYPE
|
|
SYNTAX AprisaXEPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Index to the port table based on port number."
|
|
::= { aprisaXESingleJetIFConfigEntry 2 }
|
|
|
|
aprisaXESingleJetTrafficType OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetTrafficType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the traffic type on a Single JET port."
|
|
::= { aprisaXESingleJetIFConfigEntry 3 }
|
|
|
|
aprisaXESingleJetLoopback OBJECT-TYPE
|
|
SYNTAX FourRFLoopback
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION "Controls the traffic loopback on a Single JET port."
|
|
::= { aprisaXESingleJetIFConfigEntry 4 }
|
|
|
|
aprisaXESingleJetLineEncoding OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLineEncoding
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the line encoding, the default is
|
|
HDB3 for E1, B8ZS for T1."
|
|
::= { aprisaXESingleJetIFConfigEntry 5 }
|
|
|
|
aprisaXESingleJetPcmMode OBJECT-TYPE
|
|
SYNTAX AprisaXEPcmMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls the PCM mode, PCM31 or PCM30C."
|
|
::= { aprisaXESingleJetIFConfigEntry 6 }
|
|
|
|
aprisaXESingleJetClockSource OBJECT-TYPE
|
|
SYNTAX FourRFNetworkClockSelect
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Controls whether the port drives the clock soure or not."
|
|
::= { aprisaXESingleJetIFConfigEntry 7 }
|
|
|
|
aprisaXESingleJetLineRadioLoopback OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetLoopbacks
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the E1 loopback setting on a port;
|
|
OFF, Line or Radio Facing."
|
|
::= { aprisaXESingleJetIFConfigEntry 8 }
|
|
|
|
aprisaXESingleJetTxWaveFormShaper OBJECT-TYPE
|
|
SYNTAX AprisaXEQuadJetWaveFormShapers
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This indicates the T1 Tx Waveform Shaper for a port;
|
|
0~133 ft, 133~266 ft, 266~399 ft, 399~533 ft, 533~655 ft."
|
|
::= { aprisaXESingleJetIFConfigEntry 9 }
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- End Single JET
|
|
-- ***************************************************************************
|
|
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- PSC
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEPSCControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AprisaXEPSCControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Control table for PSC."
|
|
::= { aprisaXEObjects 230 }
|
|
|
|
aprisaXEPSCControlTableEntry OBJECT-TYPE
|
|
SYNTAX AprisaXEPSCControlTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Entries for PSC table."
|
|
INDEX { aprisaXEPSCControlSlotIndex }
|
|
::= { aprisaXEPSCControlTable 1 }
|
|
|
|
AprisaXEPSCControlTableEntry ::= SEQUENCE {
|
|
aprisaXEPSCControlSlotIndex INTEGER,
|
|
aprisaXEPSCActiveRadio AprisaXEPSCActiveRadio,
|
|
aprisaXEPSCActiveTx AprisaXEPSCActiveTx,
|
|
aprisaXEPSCDemodAligmentStatusPSC FourRFAlarmStatus,
|
|
aprisaXEPSCDemodAligmentStatusPIC FourRFAlarmStatus
|
|
}
|
|
|
|
aprisaXEPSCControlSlotIndex OBJECT-TYPE
|
|
SYNTAX AprisaXESlotNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot index for PSC Control Table."
|
|
::= { aprisaXEPSCControlTableEntry 1 }
|
|
|
|
aprisaXEPSCActiveRadio OBJECT-TYPE
|
|
SYNTAX AprisaXEPSCActiveRadio
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the reception mode of the PSC."
|
|
::= { aprisaXEPSCControlTableEntry 2 }
|
|
|
|
aprisaXEPSCActiveTx OBJECT-TYPE
|
|
SYNTAX AprisaXEPSCActiveTx
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Indicates the currently active transmitter."
|
|
::= { aprisaXEPSCControlTableEntry 3 }
|
|
|
|
aprisaXEPSCDemodAlignmentStatusPSC OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the demodulator alignment on the PSC."
|
|
::= { aprisaXEPSCControlTableEntry 4 }
|
|
|
|
aprisaXEPSCDemodAlignmentStatusPIC OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Status of the demodulator alignment on the PIC."
|
|
::= { aprisaXEPSCControlTableEntry 5 }
|
|
|
|
-- ***************************************************************************
|
|
-- End PSC
|
|
-- ***************************************************************************
|
|
|
|
|
|
-- ***************************************************************************
|
|
-- HSD Parameter Comparison
|
|
-- ***************************************************************************
|
|
|
|
aprisaXEHSDParameterCompare OBJECT IDENTIFIER ::= { aprisaXEObjects 235 }
|
|
|
|
aprisaXEHSDParameterMismatch OBJECT-TYPE
|
|
SYNTAX FourRFAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "If there is a parameter (OID) mismatch between
|
|
Radio A and Radio B"
|
|
::= { aprisaXEHSDParameterCompare 1 }
|
|
|
|
aprisaXEHSDParameterCompareChecking OBJECT-TYPE
|
|
SYNTAX INTEGER { off (0),
|
|
on (1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Enables/disables HSD paramter compare checking between
|
|
Radio A and Radio B"
|
|
::= { aprisaXEHSDParameterCompare 2 }
|
|
|
|
aprisaXEHSDParameterCompareGroup OBJECT-GROUP
|
|
OBJECTS { aprisaXEHSDParameterMismatch,
|
|
aprisaXEHSDParameterCompareChecking
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The AprisaXE HSD Parameter Comparison group."
|
|
::= { aprisaXEGroups 305 }
|
|
|
|
-- ***************************************************************************
|
|
-- HSD Parameter Comparison
|
|
-- ***************************************************************************
|
|
|
|
|
|