- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
629 lines
21 KiB
Text
629 lines
21 KiB
Text
-- *****************************************************************
|
|
-- POWER-ETHERNET-MIB
|
|
--
|
|
-- This mib was extracted from RFC 3621
|
|
--
|
|
-- Copyright (c) 2006, 2009 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, mib-2, OBJECT-TYPE, Integer32,
|
|
Gauge32, Counter32, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
TruthValue
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB;
|
|
|
|
powerEthernetMIB MODULE-IDENTITY
|
|
|
|
LAST-UPDATED "200311240000Z" -- November 24, 2003
|
|
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
|
|
Working Group"
|
|
|
|
CONTACT-INFO
|
|
"
|
|
WG Charter:
|
|
http://www.ietf.org/html.charters/hubmib-charter.html
|
|
|
|
Mailing lists:
|
|
General Discussion: hubmib@ietf.org
|
|
To Subscribe: hubmib-requests@ietf.org
|
|
In Body: subscribe your_email_address
|
|
|
|
Chair: Dan Romascanu
|
|
Avaya
|
|
Tel: +972-3-645-8414
|
|
Email: dromasca@avaya.com
|
|
|
|
Editor: Avi Berger
|
|
PowerDsine Inc.
|
|
Tel: 972-9-7755100 Ext 307
|
|
Fax: 972-9-7755120
|
|
E-mail: avib@PowerDsine.com
|
|
"
|
|
|
|
DESCRIPTION
|
|
"The MIB module for managing Power Source Equipment
|
|
(PSE) working according to the IEEE 802.af Powered
|
|
Ethernet (DTE Power via MDI) standard.
|
|
|
|
The following terms are used throughout this
|
|
MIB module. For complete formal definitions,
|
|
the IEEE 802.3 standards should be consulted
|
|
wherever possible:
|
|
|
|
Group - A recommended, but optional, entity
|
|
defined by the IEEE 802.3 management standard,
|
|
in order to support a modular numbering scheme.
|
|
The classical example allows an implementor to
|
|
represent field-replaceable units as groups of
|
|
ports, with the port numbering matching the
|
|
modular hardware implementation.
|
|
|
|
Port - This entity identifies the port within the group
|
|
for which this entry contains information. The numbering
|
|
scheme for ports is implementation specific.
|
|
|
|
Copyright (c) The Internet Society (2003). This version
|
|
of this MIB module is part of RFC 3621; See the RFC
|
|
itself for full legal notices."
|
|
|
|
REVISION "200311240000Z" -- November 24, 2003
|
|
DESCRIPTION "Initial version, published as RFC 3621."
|
|
::= { mib-2 105 }
|
|
|
|
pethNotifications OBJECT IDENTIFIER ::= { powerEthernetMIB 0 }
|
|
pethObjects OBJECT IDENTIFIER ::= { powerEthernetMIB 1 }
|
|
pethConformance OBJECT IDENTIFIER ::= { powerEthernetMIB 2 }
|
|
|
|
-- PSE Objects
|
|
|
|
pethPsePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of objects that display and control the power
|
|
characteristics of power Ethernet ports on a Power Source
|
|
Entity (PSE) device. This group will be implemented in
|
|
managed power Ethernet switches and mid-span devices.
|
|
Values of all read-write objects in this table are
|
|
persistent at restart/reboot."
|
|
::= { pethObjects 1 }
|
|
|
|
pethPsePortEntry OBJECT-TYPE
|
|
SYNTAX PethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects that display and control the power
|
|
characteristics of a power Ethernet PSE port."
|
|
INDEX { pethPsePortGroupIndex , pethPsePortIndex }
|
|
::= { pethPsePortTable 1 }
|
|
|
|
PethPsePortEntry ::= SEQUENCE {
|
|
pethPsePortGroupIndex
|
|
Integer32,
|
|
pethPsePortIndex
|
|
Integer32,
|
|
pethPsePortAdminEnable
|
|
TruthValue,
|
|
pethPsePortPowerPairsControlAbility
|
|
TruthValue,
|
|
pethPsePortPowerPairs
|
|
INTEGER,
|
|
pethPsePortDetectionStatus
|
|
INTEGER,
|
|
pethPsePortPowerPriority
|
|
INTEGER,
|
|
pethPsePortMPSAbsentCounter
|
|
Counter32,
|
|
pethPsePortType
|
|
SnmpAdminString,
|
|
pethPsePortPowerClassifications
|
|
INTEGER,
|
|
pethPsePortInvalidSignatureCounter
|
|
Counter32,
|
|
pethPsePortPowerDeniedCounter
|
|
Counter32,
|
|
pethPsePortOverLoadCounter
|
|
Counter32,
|
|
pethPsePortShortCounter
|
|
Counter32
|
|
}
|
|
|
|
pethPsePortGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group
|
|
containing the port to which a power Ethernet PSE is
|
|
connected. Group means box in the stack, module in a
|
|
rack and the value 1 MUST be used for non-modular devices.
|
|
Furthermore, the same value MUST be used in this variable,
|
|
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
|
to refer to a given box in a stack or module in the rack."
|
|
::= { pethPsePortEntry 1 }
|
|
|
|
pethPsePortIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the power Ethernet PSE
|
|
port within group pethPsePortGroupIndex to which the
|
|
power Ethernet PSE entry is connected."
|
|
::= { pethPsePortEntry 2 }
|
|
|
|
pethPsePortAdminEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"true (1) An interface which can provide the PSE functions.
|
|
false(2) The interface will act as it would if it had no PSE
|
|
function."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.2 aPSEAdminState"
|
|
::= { pethPsePortEntry 3 }
|
|
|
|
pethPsePortPowerPairsControlAbility OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the capability of controlling the power pairs
|
|
functionality to switch pins for sourcing power.
|
|
The value true indicate that the device has the capability
|
|
to control the power pairs. When false the PSE Pinout
|
|
Alternative used cannot be controlled through the
|
|
PethPsePortAdminEnable attribute."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.3
|
|
aPSEPowerPairsControlAbility"
|
|
::= { pethPsePortEntry 4 }
|
|
|
|
pethPsePortPowerPairs OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
signal(1),
|
|
spare(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes or controls the pairs in use. If the value of
|
|
pethPsePortPowerPairsControl is true, this object is
|
|
writable.
|
|
A value of signal(1) means that the signal pairs
|
|
only are in use.
|
|
A value of spare(2) means that the spare pairs
|
|
only are in use."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.4 aPSEPowerPairs"
|
|
::= { pethPsePortEntry 5 }
|
|
|
|
pethPsePortDetectionStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
searching(2),
|
|
deliveringPower(3),
|
|
fault(4),
|
|
test(5),
|
|
otherFault(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the operational status of the port PD detection.
|
|
A value of disabled(1)- indicates that the PSE State diagram
|
|
is in the state DISABLED.
|
|
A value of deliveringPower(3) - indicates that the PSE State
|
|
diagram is in the state POWER_ON for a duration greater than
|
|
tlim max (see IEEE Std 802.3af Table 33-5 tlim).
|
|
A value of fault(4) - indicates that the PSE State diagram is
|
|
in the state TEST_ERROR.
|
|
A value of test(5) - indicates that the PSE State diagram is
|
|
in the state TEST_MODE.
|
|
A value of otherFault(6) - indicates that the PSE State
|
|
diagram is in the state IDLE due to the variable
|
|
error_conditions.
|
|
A value of searching(2)- indicates the PSE State diagram is
|
|
in a state other than those listed above."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.5
|
|
aPSEPowerDetectionStatus"
|
|
::= { pethPsePortEntry 6 }
|
|
|
|
pethPsePortPowerPriority OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
critical(1),
|
|
high(2),
|
|
low(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls the priority of the port from the point
|
|
of view of a power management algorithm. The priority that
|
|
is set by this variable could be used by a control mechanism
|
|
that prevents over current situations by disconnecting first
|
|
ports with lower power priority. Ports that connect devices
|
|
critical to the operation of the network - like the E911
|
|
telephones ports - should be set to higher priority."
|
|
::= { pethPsePortEntry 7 }
|
|
|
|
pethPsePortMPSAbsentCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is incremented when the PSE state diagram
|
|
transitions directly from the state POWER_ON to the
|
|
state IDLE due to tmpdo_timer_done being asserted."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.11
|
|
aPSEMPSAbsentCounter"
|
|
::= { pethPsePortEntry 8 }
|
|
|
|
pethPsePortType OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A manager will set the value of this variable to indicate
|
|
the type of powered device that is connected to the port.
|
|
The default value supplied by the agent if no value has
|
|
ever been set should be a zero-length octet string."
|
|
::= { pethPsePortEntry 9 }
|
|
|
|
pethPsePortPowerClassifications OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
class0(1),
|
|
class1(2),
|
|
class2(3),
|
|
class3(4),
|
|
class4(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Classification is a way to tag different terminals on the
|
|
Power over LAN network according to their power consumption.
|
|
Devices such as IP telephones, WLAN access points and others,
|
|
will be classified according to their power requirements.
|
|
|
|
The meaning of the classification labels is defined in the
|
|
IEEE specification.
|
|
|
|
This variable is valid only while a PD is being powered,
|
|
that is, while the attribute pethPsePortDetectionStatus
|
|
is reporting the enumeration deliveringPower."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.6
|
|
aPSEPowerClassification"
|
|
::= { pethPsePortEntry 10 }
|
|
|
|
pethPsePortInvalidSignatureCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is incremented when the PSE state diagram
|
|
enters the state SIGNATURE_INVALID."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.7
|
|
aPSEInvalidSignatureCounter"
|
|
::= { pethPsePortEntry 11 }
|
|
|
|
pethPsePortPowerDeniedCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is incremented when the PSE state diagram
|
|
enters the state POWER_DENIED."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.8
|
|
aPSEPowerDeniedCounter"
|
|
::= { pethPsePortEntry 12 }
|
|
|
|
pethPsePortOverLoadCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is incremented when the PSE state diagram
|
|
enters the state ERROR_DELAY_OVER."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.9
|
|
aPSEOverLoadCounter"
|
|
::= { pethPsePortEntry 13 }
|
|
|
|
pethPsePortShortCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This counter is incremented when the PSE state diagram
|
|
enters the state ERROR_DELAY_SHORT."
|
|
REFERENCE
|
|
"IEEE Std 802.3af Section 30.9.1.1.10
|
|
aPSEShortCounter"
|
|
::= { pethPsePortEntry 14 }
|
|
|
|
-- Main PSE Objects
|
|
|
|
pethMainPseObjects OBJECT IDENTIFIER ::= { pethObjects 3 }
|
|
|
|
pethMainPseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of objects that display and control attributes
|
|
of the main power source in a PSE device. Ethernet
|
|
switches are one example of boxes that would support
|
|
these objects.
|
|
Values of all read-write objects in this table are
|
|
persistent at restart/reboot."
|
|
::= { pethMainPseObjects 1 }
|
|
|
|
pethMainPseEntry OBJECT-TYPE
|
|
SYNTAX PethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects that display and control the Main
|
|
power of a PSE. "
|
|
INDEX { pethMainPseGroupIndex }
|
|
::= { pethMainPseTable 1 }
|
|
|
|
PethMainPseEntry ::= SEQUENCE {
|
|
pethMainPseGroupIndex
|
|
Integer32,
|
|
pethMainPsePower
|
|
Gauge32 ,
|
|
pethMainPseOperStatus
|
|
INTEGER,
|
|
pethMainPseConsumptionPower
|
|
Gauge32,
|
|
pethMainPseUsageThreshold
|
|
Integer32
|
|
}
|
|
pethMainPseGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group to which
|
|
power Ethernet PSE is connected. Group means (box in
|
|
the stack, module in a rack) and the value 1 MUST be
|
|
used for non-modular devices. Furthermore, the same
|
|
value MUST be used in this variable, pethPsePortGroupIndex,
|
|
and pethNotificationControlGroupIndex to refer to a
|
|
given box in a stack or module in a rack."
|
|
::= { pethMainPseEntry 1 }
|
|
|
|
pethMainPsePower OBJECT-TYPE
|
|
SYNTAX Gauge32 (1..65535)
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nominal power of the PSE expressed in Watts."
|
|
::= { pethMainPseEntry 2 }
|
|
|
|
pethMainPseOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
faulty(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operational status of the main PSE."
|
|
::= { pethMainPseEntry 3 }
|
|
|
|
pethMainPseConsumptionPower OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "Watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measured usage power expressed in Watts."
|
|
::= { pethMainPseEntry 4 }
|
|
|
|
pethMainPseUsageThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (1..99)
|
|
UNITS "%"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage threshold expressed in percents for
|
|
comparing the measured power and initiating
|
|
an alarm if the threshold is exceeded."
|
|
::= { pethMainPseEntry 5 }
|
|
|
|
-- Notification Control Objects
|
|
|
|
pethNotificationControl OBJECT IDENTIFIER ::= { pethObjects 4 }
|
|
|
|
pethNotificationControlTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PethNotificationControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of objects that display and control the
|
|
Notification on a PSE device.
|
|
Values of all read-write objects in this table are
|
|
persistent at restart/reboot."
|
|
::= { pethNotificationControl 1 }
|
|
|
|
pethNotificationControlEntry OBJECT-TYPE
|
|
SYNTAX PethNotificationControlEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set of objects that control the Notification events."
|
|
INDEX { pethNotificationControlGroupIndex }
|
|
::= { pethNotificationControlTable 1 }
|
|
|
|
PethNotificationControlEntry ::= SEQUENCE {
|
|
pethNotificationControlGroupIndex
|
|
Integer32,
|
|
pethNotificationControlEnable
|
|
TruthValue
|
|
}
|
|
pethNotificationControlGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group. Group
|
|
means box in the stack, module in a rack and the value
|
|
1 MUST be used for non-modular devices. Furthermore,
|
|
the same value MUST be used in this variable,
|
|
pethPsePortGroupIndex, and
|
|
pethMainPseGroupIndex to refer to a given box in a
|
|
stack or module in a rack. "
|
|
::= { pethNotificationControlEntry 1 }
|
|
|
|
pethNotificationControlEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls, on a per-group basis, whether
|
|
or not notifications from the agent are enabled. The
|
|
value true(1) means that notifications are enabled; the
|
|
value false(2) means that they are not."
|
|
::= { pethNotificationControlEntry 2 }
|
|
|
|
--
|
|
-- Notifications Section
|
|
--
|
|
--
|
|
|
|
pethPsePortOnOffNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethPsePortDetectionStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates if Pse Port is delivering or
|
|
not power to the PD. This Notification SHOULD be sent on
|
|
every status change except in the searching mode.
|
|
At least 500 msec must elapse between notifications
|
|
being emitted by the same object instance."
|
|
::= { pethNotifications 1 }
|
|
|
|
pethMainPowerUsageOnNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethMainPseConsumptionPower }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicate PSE Threshold usage
|
|
indication is on, the usage power is above the
|
|
threshold. At least 500 msec must elapse between
|
|
notifications being emitted by the same object
|
|
instance."
|
|
::= { pethNotifications 2 }
|
|
|
|
pethMainPowerUsageOffNotification NOTIFICATION-TYPE
|
|
OBJECTS { pethMainPseConsumptionPower }
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This Notification indicates PSE Threshold usage indication
|
|
off, the usage power is below the threshold.
|
|
At least 500 msec must elapse between notifications being
|
|
emitted by the same object instance."
|
|
::= { pethNotifications 3 }
|
|
|
|
--
|
|
-- Conformance Section
|
|
--
|
|
pethCompliances OBJECT IDENTIFIER ::= { pethConformance 1 }
|
|
pethGroups OBJECT IDENTIFIER ::= { pethConformance 2 }
|
|
|
|
pethCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describes the requirements for conformance to the
|
|
Power Ethernet MIB."
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { pethPsePortGroup,
|
|
pethPsePortNotificationGroup,
|
|
pethNotificationControlGroup
|
|
}
|
|
GROUP pethMainPseGroup
|
|
DESCRIPTION
|
|
"The pethMainPseGroup is mandatory for PSE systems
|
|
that implement a main power supply."
|
|
GROUP pethMainPowerNotificationGroup
|
|
DESCRIPTION
|
|
"The pethMainPowerNotificationGroup is mandatory for
|
|
PSE systems that implement a main power supply."
|
|
::= { pethCompliances 1 }
|
|
|
|
pethPsePortGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pethPsePortAdminEnable,
|
|
pethPsePortPowerPairsControlAbility,
|
|
pethPsePortPowerPairs,
|
|
pethPsePortDetectionStatus,
|
|
pethPsePortPowerPriority,
|
|
pethPsePortMPSAbsentCounter,
|
|
pethPsePortInvalidSignatureCounter,
|
|
pethPsePortPowerDeniedCounter,
|
|
pethPsePortOverLoadCounter,
|
|
pethPsePortShortCounter,
|
|
pethPsePortType,
|
|
pethPsePortPowerClassifications
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PSE Port objects."
|
|
::= { pethGroups 1 }
|
|
|
|
pethMainPseGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pethMainPsePower,
|
|
pethMainPseOperStatus,
|
|
pethMainPseConsumptionPower,
|
|
pethMainPseUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Main PSE Objects. "
|
|
::= { pethGroups 2 }
|
|
|
|
pethNotificationControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pethNotificationControlEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification Control Objects. "
|
|
::= { pethGroups 3 }
|
|
|
|
pethPsePortNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { pethPsePortOnOffNotification}
|
|
STATUS current
|
|
DESCRIPTION "Pse Port Notifications."
|
|
::= { pethGroups 4 }
|
|
|
|
pethMainPowerNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { pethMainPowerUsageOnNotification,
|
|
pethMainPowerUsageOffNotification}
|
|
STATUS current
|
|
DESCRIPTION "Main PSE Notifications."
|
|
::= { pethGroups 5 }
|
|
|
|
END
|
|
|