- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
3525 lines
82 KiB
Text
Executable file
3525 lines
82 KiB
Text
Executable file
|
|
VUTLAN-SYSTEM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY,
|
|
enterprises, Integer32
|
|
FROM SNMPv2-SMI;
|
|
|
|
vutlan MODULE-IDENTITY
|
|
LAST-UPDATED "202102100000Z"
|
|
ORGANIZATION
|
|
"Vutlan s.r.o."
|
|
CONTACT-INFO
|
|
"info@vutlan.com"
|
|
DESCRIPTION
|
|
"Vutlan monitoring units"
|
|
::= { enterprises 39052 }
|
|
|
|
ctlUnit OBJECT IDENTIFIER ::= { vutlan 1 }
|
|
ctlNotifiers OBJECT IDENTIFIER ::= { vutlan 2 }
|
|
ctlVirtualDevices OBJECT IDENTIFIER ::= { vutlan 3 }
|
|
ctlHardwareDevices OBJECT IDENTIFIER ::= { vutlan 4 }
|
|
ctIInternalSensors OBJECT IDENTIFIER ::= { vutlan 5 }
|
|
ctlCANSensors OBJECT IDENTIFIER ::= { vutlan 6 }
|
|
ctlRsSensors OBJECT IDENTIFIER ::= { vutlan 7 }
|
|
|
|
ctlUnitModulesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlUnitModulesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlUnit 1 }
|
|
|
|
ctlUnitModulesEntry OBJECT-TYPE
|
|
SYNTAX CtlUnitModulesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of module"
|
|
INDEX { ctlUnitModuleId }
|
|
::= { ctlUnitModulesTable 1 }
|
|
|
|
CtlUnitModulesEntry ::= SEQUENCE {
|
|
ctlUnitModuleId
|
|
Integer32,
|
|
ctlUnitModulePcode
|
|
Integer32,
|
|
ctlUnitModuleSN
|
|
Integer32,
|
|
ctlUnitModuleClass
|
|
OCTET STRING,
|
|
ctlUnitModuleType
|
|
OCTET STRING,
|
|
ctlUnitModuleName
|
|
OCTET STRING,
|
|
ctlUnitModuleState
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlUnitModuleId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of module"
|
|
::= { ctlUnitModulesEntry 1 }
|
|
|
|
ctlUnitModulePcode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Product code of module"
|
|
::= { ctlUnitModulesEntry 2 }
|
|
|
|
ctlUnitModuleSN OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of module"
|
|
::= { ctlUnitModulesEntry 3 }
|
|
|
|
ctlUnitModuleClass OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Class of module"
|
|
::= { ctlUnitModulesEntry 4 }
|
|
|
|
ctlUnitModuleType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of module"
|
|
::= { ctlUnitModulesEntry 5 }
|
|
|
|
ctlUnitModuleName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of module"
|
|
::= { ctlUnitModulesEntry 6 }
|
|
|
|
ctlUnitModuleState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of module"
|
|
::= { ctlUnitModulesEntry 7 }
|
|
|
|
ctlUnitGroupsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlUnitGroupsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlUnit 2 }
|
|
|
|
ctlUnitGroupsEntry OBJECT-TYPE
|
|
SYNTAX CtlUnitGroupsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ctlUnitGroupId }
|
|
::= { ctlUnitGroupsTable 1 }
|
|
|
|
CtlUnitGroupsEntry ::= SEQUENCE {
|
|
ctlUnitGroupId
|
|
Integer32,
|
|
ctlUnitGroupName
|
|
OCTET STRING,
|
|
ctlUnitGroupDesc
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlUnitGroupId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of group"
|
|
::= { ctlUnitGroupsEntry 1 }
|
|
|
|
ctlUnitGroupName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of group"
|
|
::= { ctlUnitGroupsEntry 2 }
|
|
|
|
ctlUnitGroupDesc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of group"
|
|
::= { ctlUnitGroupsEntry 3 }
|
|
|
|
ctlUnitElementsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlUnitElementsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlUnit 3 }
|
|
|
|
ctlUnitElementsEntry OBJECT-TYPE
|
|
SYNTAX CtlUnitElementsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ctlUnitElementId }
|
|
::= { ctlUnitElementsTable 1 }
|
|
|
|
CtlUnitElementsEntry ::= SEQUENCE {
|
|
ctlUnitElementId
|
|
Integer32,
|
|
ctlUnitElementGroup
|
|
Integer32,
|
|
ctlUnitElementModule
|
|
Integer32,
|
|
ctlUnitElementNum
|
|
Integer32,
|
|
ctlUnitElementClass
|
|
OCTET STRING,
|
|
ctlUnitElementType
|
|
OCTET STRING,
|
|
ctlUnitElementName
|
|
OCTET STRING,
|
|
ctlUnitElementState
|
|
OCTET STRING,
|
|
ctlUnitElementValue
|
|
OCTET STRING,
|
|
ctlUnitElementSpec
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlUnitElementId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of element"
|
|
::= { ctlUnitElementsEntry 1 }
|
|
|
|
ctlUnitElementGroup OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of element"
|
|
::= { ctlUnitElementsEntry 2 }
|
|
|
|
ctlUnitElementModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of element"
|
|
::= { ctlUnitElementsEntry 3 }
|
|
|
|
ctlUnitElementNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of elemnt's in module"
|
|
::= { ctlUnitElementsEntry 4 }
|
|
|
|
ctlUnitElementClass OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Class of element"
|
|
::= { ctlUnitElementsEntry 5 }
|
|
|
|
ctlUnitElementType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of element"
|
|
::= { ctlUnitElementsEntry 6 }
|
|
|
|
ctlUnitElementName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of element"
|
|
::= { ctlUnitElementsEntry 7 }
|
|
|
|
ctlUnitElementState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of element"
|
|
::= { ctlUnitElementsEntry 8 }
|
|
|
|
ctlUnitElementValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of element"
|
|
::= { ctlUnitElementsEntry 9 }
|
|
|
|
ctlUnitElementSpec OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Special parameters for element"
|
|
::= { ctlUnitElementsEntry 10 }
|
|
|
|
ctlUnitLogicsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlUnitLogicsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlUnit 4 }
|
|
|
|
ctlUnitLogicsEntry OBJECT-TYPE
|
|
SYNTAX CtlUnitLogicsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of logic"
|
|
INDEX { ctlUnitLogicId }
|
|
::= { ctlUnitLogicsTable 1 }
|
|
|
|
CtlUnitLogicsEntry ::= SEQUENCE {
|
|
ctlUnitLogicId
|
|
Integer32,
|
|
ctlUnitLogicName
|
|
OCTET STRING,
|
|
ctlUnitLogicDesc
|
|
OCTET STRING,
|
|
ctlUnitLogicDisable
|
|
Integer32,
|
|
ctlUnitLogicRowStatus
|
|
Integer32
|
|
}
|
|
|
|
-- Id of logic's
|
|
|
|
ctlUnitLogicId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of logic scheme"
|
|
::= { ctlUnitLogicsEntry 1 }
|
|
|
|
ctlUnitLogicName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of logic scheme"
|
|
::= { ctlUnitLogicsEntry 2 }
|
|
|
|
ctlUnitLogicDesc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..256))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of logic scheme"
|
|
::= { ctlUnitLogicsEntry 3 }
|
|
|
|
ctlUnitLogicDisable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Disable of logic's in secs, 0 for enable "
|
|
::= { ctlUnitLogicsEntry 4 }
|
|
|
|
ctlUnitLogicRowStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlUnitLogicsEntry 5 }
|
|
|
|
|
|
ctlUnitTrapNotification NOTIFICATION-TYPE
|
|
OBJECTS { macroLogicDefinition, macroStateOfSensors, macroDateAndTime,
|
|
macroLogicName, macroSensorName, macroSensorState, macroSensorValue,
|
|
macroLastModifiedSensorID, trapID, trapName }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP trap notification."
|
|
::= { ctlUnit 5 }
|
|
|
|
-- The trap description objects
|
|
|
|
macroLogicDefinition OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Description of the logic scheme that has triggered."
|
|
::= { ctlUnitTrapNotification 1 }
|
|
|
|
macroStateOfSensors OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Readings of sensors in the logic scheme."
|
|
::= { ctlUnitTrapNotification 2 }
|
|
|
|
macroDateAndTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logic scheme response time."
|
|
::= { ctlUnitTrapNotification 3 }
|
|
|
|
macroLogicName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of logic scheme."
|
|
::= { ctlUnitTrapNotification 4 }
|
|
|
|
macroSensorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the sensor which triggered the logic scheme."
|
|
::= { ctlUnitTrapNotification 5 }
|
|
|
|
macroSensorState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of the sensor in the logic scheme that has triggered.
|
|
Maybe one of these: normal, warning, low warning, high warning,
|
|
alarm, low alarm, high alarm, on, off, not connected"
|
|
::= { ctlUnitTrapNotification 6 }
|
|
|
|
macroSensorValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value measured by the sensor or logic level."
|
|
::= { ctlUnitTrapNotification 7 }
|
|
|
|
macroLastModifiedSensorID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sensor ID that triggered the operation of the logic circuit."
|
|
::= { ctlUnitTrapNotification 8 }
|
|
|
|
trapID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ID of SNMP trap."
|
|
::= { ctlUnitTrapNotification 20 }
|
|
|
|
trapName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of SNMP trap."
|
|
::= { ctlUnitTrapNotification 21 }
|
|
|
|
|
|
ctlUnitSaveToFlash OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Save current setting to flash memory"
|
|
::= { ctlUnit 6 }
|
|
|
|
|
|
-- System information entry
|
|
|
|
ctlUnitSystem OBJECT IDENTIFIER ::= { ctlUnit 7 }
|
|
|
|
systemDevType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device type"
|
|
::= { ctlUnitSystem 1 }
|
|
|
|
systemFirmware OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firmware version"
|
|
::= { ctlUnitSystem 2 }
|
|
|
|
systemKernel OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System kernel version"
|
|
::= { ctlUnitSystem 3 }
|
|
|
|
systemOpTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total operating time"
|
|
::= { ctlUnitSystem 4 }
|
|
|
|
systemUpTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Session time"
|
|
::= { ctlUnitSystem 5 }
|
|
|
|
systemCpuUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU usage (%)"
|
|
::= { ctlUnitSystem 6 }
|
|
|
|
systemMemUsage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Memory usage (%)"
|
|
::= { ctlUnitSystem 7 }
|
|
|
|
systemState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System state"
|
|
::= { ctlUnitSystem 8 }
|
|
|
|
systemHostname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Hostname"
|
|
::= { ctlUnitSystem 9 }
|
|
|
|
systemDescSN OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Number"
|
|
::= { ctlUnitSystem 10 }
|
|
|
|
systemDescContacts OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..1024))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Contacts"
|
|
::= { ctlUnitSystem 11 }
|
|
|
|
systemDescLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..1024))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Location description"
|
|
::= { ctlUnitSystem 12 }
|
|
|
|
systemDescComment OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..1024))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Comment"
|
|
::= { ctlUnitSystem 13 }
|
|
|
|
systemMAC OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet MAC address of the unit"
|
|
::= { ctlUnitSystem 14 }
|
|
|
|
|
|
ctlUnitReboot OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reboot the unit"
|
|
::= { ctlUnit 8 }
|
|
|
|
|
|
ctlNotifiersMailersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlNotifiersMailersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlNotifiers 1 }
|
|
|
|
ctlNotifiersMailersEntry OBJECT-TYPE
|
|
SYNTAX CtlNotifiersMailersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of email notify"
|
|
INDEX { ctlNotifiersMailerId }
|
|
::= { ctlNotifiersMailersTable 1 }
|
|
|
|
CtlNotifiersMailersEntry ::= SEQUENCE {
|
|
ctlNotifiersMailerId
|
|
Integer32,
|
|
ctlNotifiersMailerModule
|
|
Integer32,
|
|
ctlNotifiersMailerNum
|
|
Integer32,
|
|
ctlNotifiersMailerType
|
|
OCTET STRING,
|
|
ctlNotifiersMailerName
|
|
OCTET STRING,
|
|
ctlNotifiersMailerState
|
|
OCTET STRING,
|
|
ctlNotifiersMailerValue
|
|
OCTET STRING,
|
|
ctlNotifiersMailerServer
|
|
OCTET STRING,
|
|
ctlNotifiersMailerPort
|
|
Integer32,
|
|
ctlNotifiersMailerLogin
|
|
OCTET STRING,
|
|
ctlNotifiersMailerPassword
|
|
Integer32,
|
|
ctlNotifiersMailersTo
|
|
OCTET STRING,
|
|
ctlNotifiersMailersFrom
|
|
OCTET STRING,
|
|
ctlNotifiersMailerMessage
|
|
Integer32
|
|
}
|
|
|
|
ctlNotifiersMailerId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of mailer"
|
|
::= { ctlNotifiersMailersEntry 1 }
|
|
|
|
ctlNotifiersMailerModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of mailer"
|
|
::= { ctlNotifiersMailersEntry 2 }
|
|
|
|
ctlNotifiersMailerNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for mailer"
|
|
::= { ctlNotifiersMailersEntry 3 }
|
|
|
|
ctlNotifiersMailerType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of element"
|
|
::= { ctlNotifiersMailersEntry 4 }
|
|
|
|
ctlNotifiersMailerName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of mailer"
|
|
::= { ctlNotifiersMailersEntry 5 }
|
|
|
|
ctlNotifiersMailerState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of mailer"
|
|
::= { ctlNotifiersMailersEntry 6 }
|
|
|
|
ctlNotifiersMailerValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of mailer"
|
|
::= { ctlNotifiersMailersEntry 7 }
|
|
|
|
ctlNotifiersMailerServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mailserver adress"
|
|
::= { ctlNotifiersMailersEntry 8 }
|
|
|
|
ctlNotifiersMailerPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port of mailserver"
|
|
::= { ctlNotifiersMailersEntry 9 }
|
|
|
|
ctlNotifiersMailerLogin OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Login on mailserver"
|
|
::= { ctlNotifiersMailersEntry 10 }
|
|
|
|
ctlNotifiersMailerPassword OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Password for mailserver"
|
|
::= { ctlNotifiersMailersEntry 11 }
|
|
|
|
ctlNotifiersMailersTo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"To"
|
|
::= { ctlNotifiersMailersEntry 12 }
|
|
|
|
ctlNotifiersMailersFrom OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..512))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"From"
|
|
::= { ctlNotifiersMailersEntry 13 }
|
|
|
|
ctlNotifiersMailerMessage OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Message"
|
|
::= { ctlNotifiersMailersEntry 14 }
|
|
|
|
ctlNotifiersTrapsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlNotifiersTrapsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlNotifiers 2 }
|
|
|
|
ctlNotifiersTrapsEntry OBJECT-TYPE
|
|
SYNTAX CtlNotifiersTrapsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of trap notify"
|
|
INDEX { ctlNotifiersTrapId }
|
|
::= { ctlNotifiersTrapsTable 1 }
|
|
|
|
CtlNotifiersTrapsEntry ::= SEQUENCE {
|
|
ctlNotifiersTrapId
|
|
Integer32,
|
|
ctlNotifiersTrapModule
|
|
Integer32,
|
|
ctlNotifiersTrapNum
|
|
Integer32,
|
|
ctlNotifiersTrapType
|
|
OCTET STRING,
|
|
ctlNotifiersTrapName
|
|
OCTET STRING,
|
|
ctlNotifiersTrapState
|
|
OCTET STRING,
|
|
ctlNotifiersTrapValue
|
|
OCTET STRING,
|
|
ctlNotifiersTrapServer
|
|
OCTET STRING,
|
|
ctlNotifiersTrapPort
|
|
Integer32,
|
|
ctlNotifiersTrapVersion
|
|
OCTET STRING,
|
|
ctlNotifiersTrapCommunity
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlNotifiersTrapId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of trap"
|
|
::= { ctlNotifiersTrapsEntry 1 }
|
|
|
|
ctlNotifiersTrapModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of trap"
|
|
::= { ctlNotifiersTrapsEntry 2 }
|
|
|
|
ctlNotifiersTrapNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for trap"
|
|
::= { ctlNotifiersTrapsEntry 3 }
|
|
|
|
ctlNotifiersTrapType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of element"
|
|
::= { ctlNotifiersTrapsEntry 4 }
|
|
|
|
ctlNotifiersTrapName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of trap"
|
|
::= { ctlNotifiersTrapsEntry 5 }
|
|
|
|
ctlNotifiersTrapState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of trap"
|
|
::= { ctlNotifiersTrapsEntry 6 }
|
|
|
|
ctlNotifiersTrapValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of trap"
|
|
::= { ctlNotifiersTrapsEntry 7 }
|
|
|
|
ctlNotifiersTrapServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receiver address for trap"
|
|
::= { ctlNotifiersTrapsEntry 8 }
|
|
|
|
ctlNotifiersTrapPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port of trap receiver"
|
|
::= { ctlNotifiersTrapsEntry 9 }
|
|
|
|
ctlNotifiersTrapVersion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of trap"
|
|
::= { ctlNotifiersTrapsEntry 10 }
|
|
|
|
ctlNotifiersTrapCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Password for mailserver"
|
|
::= { ctlNotifiersTrapsEntry 11 }
|
|
|
|
ctlNotifiersSMSsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlNotifiersSMSsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlNotifiers 3 }
|
|
|
|
ctlNotifiersSMSsEntry OBJECT-TYPE
|
|
SYNTAX CtlNotifiersSMSsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of SMS notify"
|
|
INDEX { ctlNotifiersSMSId }
|
|
::= { ctlNotifiersSMSsTable 1 }
|
|
|
|
CtlNotifiersSMSsEntry ::= SEQUENCE {
|
|
ctlNotifiersSMSId
|
|
Integer32,
|
|
ctlNotifiersSMSModule
|
|
Integer32,
|
|
ctlNotifiersSMSNum
|
|
Integer32,
|
|
ctlNotifiersSMSType
|
|
OCTET STRING,
|
|
ctlNotifiersSMSName
|
|
OCTET STRING,
|
|
ctlNotifiersSMSState
|
|
OCTET STRING,
|
|
ctlNotifiersSMSValue
|
|
Integer32,
|
|
ctlNotifiersSMSTo
|
|
OCTET STRING,
|
|
ctlNotifiersSMSMessage
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlNotifiersSMSId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of SMS"
|
|
::= { ctlNotifiersSMSsEntry 1 }
|
|
|
|
ctlNotifiersSMSModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of SMS"
|
|
::= { ctlNotifiersSMSsEntry 2 }
|
|
|
|
ctlNotifiersSMSNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for SMS"
|
|
::= { ctlNotifiersSMSsEntry 3 }
|
|
|
|
ctlNotifiersSMSType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of SMS"
|
|
::= { ctlNotifiersSMSsEntry 4 }
|
|
|
|
ctlNotifiersSMSName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of SMS"
|
|
::= { ctlNotifiersSMSsEntry 5 }
|
|
|
|
ctlNotifiersSMSState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of SMS"
|
|
::= { ctlNotifiersSMSsEntry 6 }
|
|
|
|
ctlNotifiersSMSValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set '1' to send SMS"
|
|
::= { ctlNotifiersSMSsEntry 7 }
|
|
|
|
ctlNotifiersSMSTo OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Phone number"
|
|
::= { ctlNotifiersSMSsEntry 8 }
|
|
|
|
ctlNotifiersSMSMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..512))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Text of SMS message"
|
|
::= { ctlNotifiersSMSsEntry 9 }
|
|
|
|
ctlVirtualDevicesTimersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlVirtualDevicesTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlVirtualDevices 1 }
|
|
|
|
ctlVirtualDevicesTimersEntry OBJECT-TYPE
|
|
SYNTAX CtlVirtualDevicesTimersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of timer"
|
|
INDEX { ctlVirtualDevicesTimerId }
|
|
::= { ctlVirtualDevicesTimersTable 1 }
|
|
|
|
CtlVirtualDevicesTimersEntry ::= SEQUENCE {
|
|
ctlVirtualDevicesTimerId
|
|
Integer32,
|
|
ctlVirtualDevicesTimerModule
|
|
Integer32,
|
|
ctlVirtualDevicesTimerNum
|
|
Integer32,
|
|
ctlVirtualDevicesTimerType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerName
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerState
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerBegin
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerEnd
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerDays
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerMode
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTimerDayPattern
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlVirtualDevicesTimerId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 1 }
|
|
|
|
ctlVirtualDevicesTimerModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of tiimer"
|
|
::= { ctlVirtualDevicesTimersEntry 2 }
|
|
|
|
ctlVirtualDevicesTimerNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for timer"
|
|
::= { ctlVirtualDevicesTimersEntry 3 }
|
|
|
|
ctlVirtualDevicesTimerType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 4 }
|
|
|
|
ctlVirtualDevicesTimerName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 5 }
|
|
|
|
ctlVirtualDevicesTimerState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 6 }
|
|
|
|
ctlVirtualDevicesTimerValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 7 }
|
|
|
|
ctlVirtualDevicesTimerBegin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Begin time for timer (Unix timestamp)"
|
|
::= { ctlVirtualDevicesTimersEntry 8 }
|
|
|
|
ctlVirtualDevicesTimerEnd OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"End time for timer (Unix timestamp)"
|
|
::= { ctlVirtualDevicesTimersEntry 9 }
|
|
|
|
ctlVirtualDevicesTimerDays OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Days for timer"
|
|
::= { ctlVirtualDevicesTimersEntry 10 }
|
|
|
|
ctlVirtualDevicesTimerMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mode of timer"
|
|
::= { ctlVirtualDevicesTimersEntry 11 }
|
|
|
|
ctlVirtualDevicesTimerDayPattern OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timer pattern for every day of week"
|
|
::= { ctlVirtualDevicesTimersEntry 12 }
|
|
|
|
|
|
ctlVirtualDevicesPingsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlVirtualDevicesPingsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlVirtualDevices 2 }
|
|
|
|
ctlVirtualDevicesPingsEntry OBJECT-TYPE
|
|
SYNTAX CtlVirtualDevicesPingsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of ping"
|
|
INDEX { ctlVirtualDevicesPingId }
|
|
::= { ctlVirtualDevicesPingsTable 1 }
|
|
|
|
CtlVirtualDevicesPingsEntry ::= SEQUENCE {
|
|
ctlVirtualDevicesPingId
|
|
Integer32,
|
|
ctlVirtualDevicesPingModule
|
|
Integer32,
|
|
ctlVirtualDevicesPingNum
|
|
Integer32,
|
|
ctlVirtualDevicesPingType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingName
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingState
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingPeriod
|
|
Integer32,
|
|
ctlVirtualDevicesPingRTT
|
|
Integer32,
|
|
ctlVirtualDevicesPingServer
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingIP
|
|
OCTET STRING,
|
|
ctlVirtualDevicesPingSent
|
|
Integer32,
|
|
ctlVirtualDevicesPingReceived
|
|
Integer32,
|
|
ctlVirtualDevicesPingStatus
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlVirtualDevicesPingId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 1 }
|
|
|
|
ctlVirtualDevicesPingModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 2 }
|
|
|
|
ctlVirtualDevicesPingNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for ping"
|
|
::= { ctlVirtualDevicesPingsEntry 3 }
|
|
|
|
ctlVirtualDevicesPingType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of element"
|
|
::= { ctlVirtualDevicesPingsEntry 4 }
|
|
|
|
ctlVirtualDevicesPingName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 5 }
|
|
|
|
ctlVirtualDevicesPingState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 6 }
|
|
|
|
ctlVirtualDevicesPingValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of timer"
|
|
::= { ctlVirtualDevicesPingsEntry 7 }
|
|
|
|
ctlVirtualDevicesPingPeriod OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Period for ping"
|
|
::= { ctlVirtualDevicesPingsEntry 8 }
|
|
|
|
ctlVirtualDevicesPingRTT OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Round Trip Time of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 9 }
|
|
|
|
ctlVirtualDevicesPingServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server for ping"
|
|
::= { ctlVirtualDevicesPingsEntry 10 }
|
|
|
|
ctlVirtualDevicesPingIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Resolved IP for ping"
|
|
::= { ctlVirtualDevicesPingsEntry 11 }
|
|
|
|
ctlVirtualDevicesPingSent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sent pings"
|
|
::= { ctlVirtualDevicesPingsEntry 12 }
|
|
|
|
ctlVirtualDevicesPingReceived OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of received pings"
|
|
::= { ctlVirtualDevicesPingsEntry 13 }
|
|
|
|
ctlVirtualDevicesPingStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of ping"
|
|
::= { ctlVirtualDevicesPingsEntry 14 }
|
|
|
|
ctlVirtualDevicesTriggersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlVirtualDevicesTriggersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlVirtualDevices 3 }
|
|
|
|
ctlVirtualDevicesTriggersEntry OBJECT-TYPE
|
|
SYNTAX CtlVirtualDevicesTriggersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ctlVirtualDevicesTriggerId }
|
|
::= { ctlVirtualDevicesTriggersTable 1 }
|
|
|
|
CtlVirtualDevicesTriggersEntry ::= SEQUENCE {
|
|
ctlVirtualDevicesTriggerId
|
|
Integer32,
|
|
ctlVirtualDevicesTriggerModule
|
|
Integer32,
|
|
ctlVirtualDevicesTriggerNum
|
|
Integer32,
|
|
ctlVirtualDevicesTriggerType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTriggerName
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTriggerState
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTriggerValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesTriggerReverse
|
|
Integer32
|
|
}
|
|
|
|
ctlVirtualDevicesTriggerId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 1 }
|
|
|
|
ctlVirtualDevicesTriggerModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 2 }
|
|
|
|
ctlVirtualDevicesTriggerNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of trigger in module"
|
|
::= { ctlVirtualDevicesTriggersEntry 3 }
|
|
|
|
ctlVirtualDevicesTriggerType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 4 }
|
|
|
|
ctlVirtualDevicesTriggerName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 5 }
|
|
|
|
ctlVirtualDevicesTriggerState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 6 }
|
|
|
|
ctlVirtualDevicesTriggerValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of timer"
|
|
::= { ctlVirtualDevicesTriggersEntry 7 }
|
|
|
|
ctlVirtualDevicesTriggerReverse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse of trigger"
|
|
::= { ctlVirtualDevicesTriggersEntry 8 }
|
|
|
|
ctlVirtualDevicesSnmpgetsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlVirtualDevicesSnmpgetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlVirtualDevices 4 }
|
|
|
|
ctlVirtualDevicesSnmpgetsEntry OBJECT-TYPE
|
|
SYNTAX CtlVirtualDevicesSnmpgetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { ctlVirtualDevicesSnmpgetId }
|
|
::= { ctlVirtualDevicesSnmpgetsTable 1 }
|
|
|
|
|
|
ctlVirtualDevicesAnalogsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlVirtualDevicesAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlVirtualDevices 5 }
|
|
|
|
ctlVirtualDevicesAnalogsEntry OBJECT-TYPE
|
|
SYNTAX CtlVirtualDevicesAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of analog"
|
|
INDEX { ctlVirtualDevicesAnalogId }
|
|
::= { ctlVirtualDevicesAnalogsTable 1 }
|
|
|
|
CtlVirtualDevicesAnalogsEntry ::= SEQUENCE {
|
|
ctlVirtualDevicesAnalogId
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogModule
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogNum
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogName
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogState
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogMin
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogMax
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogLowAlarm
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogLowWarning
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogHighWarning
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogHighAlarm
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogAt0
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogAt75
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogExpression
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogSpecific
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogHystType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogHystValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesAnalogHystLowAlarm
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogHystLowWarning
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogHystNormal
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogHystHighWarning
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogHystHighAlarm
|
|
Integer32,
|
|
ctlVirtualDevicesAnalogValueInt
|
|
Integer32
|
|
}
|
|
|
|
ctlVirtualDevicesAnalogId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 1 }
|
|
|
|
ctlVirtualDevicesAnalogModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 2 }
|
|
|
|
ctlVirtualDevicesAnalogNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 3 }
|
|
|
|
ctlVirtualDevicesAnalogType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 4 }
|
|
|
|
ctlVirtualDevicesAnalogName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 5 }
|
|
|
|
ctlVirtualDevicesAnalogState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 6 }
|
|
|
|
ctlVirtualDevicesAnalogValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 7 }
|
|
|
|
ctlVirtualDevicesAnalogMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum of sensor value range"
|
|
::= { ctlVirtualDevicesAnalogsEntry 8 }
|
|
|
|
ctlVirtualDevicesAnalogMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum of sensor value range"
|
|
::= { ctlVirtualDevicesAnalogsEntry 9 }
|
|
|
|
ctlVirtualDevicesAnalogLowAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm level for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 10 }
|
|
|
|
ctlVirtualDevicesAnalogLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning level for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 11 }
|
|
|
|
ctlVirtualDevicesAnalogHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning level for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 12 }
|
|
|
|
ctlVirtualDevicesAnalogHighAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm level for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 13 }
|
|
|
|
ctlVirtualDevicesAnalogAt0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At0 for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 14 }
|
|
|
|
ctlVirtualDevicesAnalogAt75 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At75 for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 15 }
|
|
|
|
ctlVirtualDevicesAnalogExpression OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expression for sensor value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 16 }
|
|
|
|
ctlVirtualDevicesAnalogSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlVirtualDevicesAnalogsEntry 17 }
|
|
|
|
|
|
ctlVirtualDevicesAnalogHystType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis type"
|
|
::= { ctlVirtualDevicesAnalogsEntry 18 }
|
|
|
|
ctlVirtualDevicesAnalogHystValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis value"
|
|
::= { ctlVirtualDevicesAnalogsEntry 19 }
|
|
|
|
ctlVirtualDevicesAnalogHystLowAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Alarm time"
|
|
::= { ctlVirtualDevicesAnalogsEntry 20 }
|
|
|
|
ctlVirtualDevicesAnalogHystLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Warning time"
|
|
::= { ctlVirtualDevicesAnalogsEntry 21 }
|
|
|
|
ctlVirtualDevicesAnalogHystNormal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Normal time"
|
|
::= { ctlVirtualDevicesAnalogsEntry 22 }
|
|
|
|
ctlVirtualDevicesAnalogHystHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Warning time"
|
|
::= { ctlVirtualDevicesAnalogsEntry 23 }
|
|
|
|
ctlVirtualDevicesAnalogHystHighAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Alarm time"
|
|
::= { ctlVirtualDevicesAnalogsEntry 24 }
|
|
|
|
ctlVirtualDevicesAnalogValueInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer value of the sensor with a multiplier of 100"
|
|
::= { ctlVirtualDevicesAnalogsEntry 25 }
|
|
|
|
|
|
CtlVirtualDevicesSnmpgetsEntry ::= SEQUENCE {
|
|
ctlVirtualDevicesSnmpgetId
|
|
Integer32,
|
|
ctlVirtualDevicesSnmpgetModule
|
|
Integer32,
|
|
ctlVirtualDevicesSnmpgetNum
|
|
Integer32,
|
|
ctlVirtualDevicesSnmpgetType
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetName
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetState
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetValue
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetStatus
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetPeriod
|
|
Integer32,
|
|
ctlVirtualDevicesSnmpgetServer
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetPort
|
|
Integer32,
|
|
ctlVirtualDevicesSnmpgetCommunity
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetOid
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetVartype
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetLowAlarm
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetLowWarning
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetHighWarning
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetHighAlarm
|
|
OCTET STRING,
|
|
ctlVirtualDevicesSnmpgetExpression
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlVirtualDevicesSnmpgetId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 1 }
|
|
|
|
ctlVirtualDevicesSnmpgetModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 2 }
|
|
|
|
ctlVirtualDevicesSnmpgetNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of snmpget in module"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 3 }
|
|
|
|
ctlVirtualDevicesSnmpgetType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 4 }
|
|
|
|
ctlVirtualDevicesSnmpgetName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 5 }
|
|
|
|
ctlVirtualDevicesSnmpgetState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 6 }
|
|
|
|
ctlVirtualDevicesSnmpgetValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 7 }
|
|
|
|
ctlVirtualDevicesSnmpgetStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 8 }
|
|
|
|
ctlVirtualDevicesSnmpgetPeriod OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Period of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 9 }
|
|
|
|
ctlVirtualDevicesSnmpgetServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 10 }
|
|
|
|
ctlVirtualDevicesSnmpgetPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Server port of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 11 }
|
|
|
|
ctlVirtualDevicesSnmpgetCommunity OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Community of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 12 }
|
|
|
|
ctlVirtualDevicesSnmpgetOid OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Oid of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 13 }
|
|
|
|
ctlVirtualDevicesSnmpgetVartype OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vartype of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 14 }
|
|
|
|
ctlVirtualDevicesSnmpgetLowAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm level of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 15 }
|
|
|
|
ctlVirtualDevicesSnmpgetLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning level of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 16 }
|
|
|
|
ctlVirtualDevicesSnmpgetHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning level of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 17 }
|
|
|
|
ctlVirtualDevicesSnmpgetHighAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm level of Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 18 }
|
|
|
|
ctlVirtualDevicesSnmpgetExpression OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expression for Snmpget"
|
|
::= { ctlVirtualDevicesSnmpgetsEntry 19 }
|
|
|
|
ctlHardwareDevicesCamerasTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlHardwareDevicesCamerasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlHardwareDevices 1 }
|
|
|
|
ctlHardwareDevicesCamerasEntry OBJECT-TYPE
|
|
SYNTAX CtlHardwareDevicesCamerasEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of camera"
|
|
INDEX { ctlHardwareDevicesCameraId }
|
|
::= { ctlHardwareDevicesCamerasTable 1 }
|
|
|
|
CtlHardwareDevicesCamerasEntry ::= SEQUENCE {
|
|
ctlHardwareDevicesCameraId
|
|
Integer32,
|
|
ctlHardwareDevicesCameraModule
|
|
Integer32,
|
|
ctlHardwareDevicesCameraNum
|
|
Integer32,
|
|
ctlHardwareDevicesCameraType
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraName
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraState
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraValue
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraURL
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraFPS
|
|
OCTET STRING,
|
|
ctlHardwareDevicesCameraResolution
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlHardwareDevicesCameraId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 1 }
|
|
|
|
ctlHardwareDevicesCameraModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 2 }
|
|
|
|
ctlHardwareDevicesCameraNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 3 }
|
|
|
|
ctlHardwareDevicesCameraType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of element"
|
|
::= { ctlHardwareDevicesCamerasEntry 4 }
|
|
|
|
ctlHardwareDevicesCameraName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 5 }
|
|
|
|
ctlHardwareDevicesCameraState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 6 }
|
|
|
|
ctlHardwareDevicesCameraValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set '1' for start clip"
|
|
::= { ctlHardwareDevicesCamerasEntry 7 }
|
|
|
|
ctlHardwareDevicesCameraURL OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..256))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP camera URL (or device path for USB)"
|
|
::= { ctlHardwareDevicesCamerasEntry 8 }
|
|
|
|
ctlHardwareDevicesCameraFPS OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FPS of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 9 }
|
|
|
|
ctlHardwareDevicesCameraResolution OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Resolution of camera"
|
|
::= { ctlHardwareDevicesCamerasEntry 10 }
|
|
|
|
|
|
ctlHardwareDevicesModemsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlHardwareDevicesModemsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlHardwareDevices 2 }
|
|
|
|
ctlHardwareDevicesModemsEntry OBJECT-TYPE
|
|
SYNTAX CtlHardwareDevicesModemsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of system modem"
|
|
INDEX { ctlHardwareDevicesModemState }
|
|
::= { ctlHardwareDevicesModemsTable 1 }
|
|
|
|
CtlHardwareDevicesModemsEntry ::= SEQUENCE {
|
|
ctlHardwareDevicesModemState
|
|
OCTET STRING,
|
|
ctlHardwareDevicesModemStatus
|
|
OCTET STRING,
|
|
ctlHardwareDevicesModemSignal
|
|
Integer32,
|
|
ctlHardwareDevicesModemOperator
|
|
OCTET STRING,
|
|
ctlHardwareDevicesModemPosition
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlHardwareDevicesModemState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem state"
|
|
::= { ctlHardwareDevicesModemsEntry 1 }
|
|
|
|
ctlHardwareDevicesModemStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem network registration status"
|
|
::= { ctlHardwareDevicesModemsEntry 2 }
|
|
|
|
ctlHardwareDevicesModemSignal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modem signal level in percent"
|
|
::= { ctlHardwareDevicesModemsEntry 3 }
|
|
|
|
ctlHardwareDevicesModemOperator OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network operator name"
|
|
::= { ctlHardwareDevicesModemsEntry 4 }
|
|
|
|
ctlHardwareDevicesModemPosition OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GPS coordinates in degrees"
|
|
::= { ctlHardwareDevicesModemsEntry 5 }
|
|
|
|
|
|
ctlInternalSensorsDiscretsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlInternalSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctIInternalSensors 1 }
|
|
|
|
ctlInternalSensorsDiscretsEntry OBJECT-TYPE
|
|
SYNTAX CtlInternalSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of discret"
|
|
INDEX { ctlInternalSensorsDiscretId }
|
|
::= { ctlInternalSensorsDiscretsTable 1 }
|
|
|
|
CtlInternalSensorsDiscretsEntry ::= SEQUENCE {
|
|
ctlInternalSensorsDiscretId
|
|
Integer32,
|
|
ctlInternalSensorsDiscretModule
|
|
Integer32,
|
|
ctlInternalSensorsDiscretNum
|
|
Integer32,
|
|
ctlInternalSensorsDiscretType
|
|
OCTET STRING,
|
|
ctlInternalSensorsDiscretName
|
|
OCTET STRING,
|
|
ctlInternalSensorsDiscretState
|
|
OCTET STRING,
|
|
ctlInternalSensorsDiscretValue
|
|
Integer32,
|
|
ctlInternalSensorsDiscretReset
|
|
Integer32,
|
|
ctlInternalSensorsDiscretLevel
|
|
Integer32,
|
|
ctlInternalSensorsDiscretReverse
|
|
Integer32,
|
|
ctlInternalSensorsDiscretSpecific
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlInternalSensorsDiscretId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 1 }
|
|
|
|
ctlInternalSensorsDiscretModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 2 }
|
|
|
|
ctlInternalSensorsDiscretNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 3 }
|
|
|
|
ctlInternalSensorsDiscretType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 4 }
|
|
|
|
ctlInternalSensorsDiscretName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 5 }
|
|
|
|
ctlInternalSensorsDiscretState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 6 }
|
|
|
|
ctlInternalSensorsDiscretValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 7 }
|
|
|
|
ctlInternalSensorsDiscretReset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 8 }
|
|
|
|
ctlInternalSensorsDiscretLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 9 }
|
|
|
|
ctlInternalSensorsDiscretReverse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse of sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 10 }
|
|
|
|
ctlInternalSensorsDiscretSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlInternalSensorsDiscretsEntry 11 }
|
|
|
|
ctlInternalSensorsAnalogsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlInternalSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctIInternalSensors 2 }
|
|
|
|
ctlInternalSensorsAnalogsEntry OBJECT-TYPE
|
|
SYNTAX CtlInternalSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of analog"
|
|
INDEX { ctlInternalSensorsAnalogId }
|
|
::= { ctlInternalSensorsAnalogsTable 1 }
|
|
|
|
CtlInternalSensorsAnalogsEntry ::= SEQUENCE {
|
|
ctlInternalSensorsAnalogId
|
|
Integer32,
|
|
ctlInternalSensorsAnalogModule
|
|
Integer32,
|
|
ctlInternalSensorsAnalogNum
|
|
Integer32,
|
|
ctlInternalSensorsAnalogType
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogName
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogState
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogValue
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogMin
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogMax
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogLowAlarm
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogLowWarning
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogHighWarning
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogHighAlarm
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogAt0
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogAt75
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogExpression
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogSpecific
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogHystType
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogHystValue
|
|
OCTET STRING,
|
|
ctlInternalSensorsAnalogHystLowAlarm
|
|
Integer32,
|
|
ctlInternalSensorsAnalogHystLowWarning
|
|
Integer32,
|
|
ctlInternalSensorsAnalogHystNormal
|
|
Integer32,
|
|
ctlInternalSensorsAnalogHystHighWarning
|
|
Integer32,
|
|
ctlInternalSensorsAnalogHystHighAlarm
|
|
Integer32,
|
|
ctlInternalSensorsAnalogValueInt
|
|
Integer32
|
|
}
|
|
|
|
ctlInternalSensorsAnalogId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 1 }
|
|
|
|
ctlInternalSensorsAnalogModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 2 }
|
|
|
|
-- Num in modules for mailer
|
|
|
|
ctlInternalSensorsAnalogNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 3 }
|
|
|
|
ctlInternalSensorsAnalogType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 4 }
|
|
|
|
ctlInternalSensorsAnalogName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 5 }
|
|
|
|
ctlInternalSensorsAnalogState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 6 }
|
|
|
|
ctlInternalSensorsAnalogValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 7 }
|
|
|
|
ctlInternalSensorsAnalogMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum of sensor value range"
|
|
::= { ctlInternalSensorsAnalogsEntry 8 }
|
|
|
|
ctlInternalSensorsAnalogMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum of sensor value range"
|
|
::= { ctlInternalSensorsAnalogsEntry 9 }
|
|
|
|
ctlInternalSensorsAnalogLowAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm level for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 10 }
|
|
|
|
ctlInternalSensorsAnalogLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning level for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 11 }
|
|
|
|
ctlInternalSensorsAnalogHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning level for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 12 }
|
|
|
|
ctlInternalSensorsAnalogHighAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm level for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 13 }
|
|
|
|
ctlInternalSensorsAnalogAt0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At0 for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 14 }
|
|
|
|
ctlInternalSensorsAnalogAt75 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At75 for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 15 }
|
|
|
|
ctlInternalSensorsAnalogExpression OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expression for sensor value"
|
|
::= { ctlInternalSensorsAnalogsEntry 16 }
|
|
|
|
ctlInternalSensorsAnalogSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlInternalSensorsAnalogsEntry 17 }
|
|
|
|
ctlInternalSensorsAnalogHystType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis type"
|
|
::= { ctlInternalSensorsAnalogsEntry 18 }
|
|
|
|
ctlInternalSensorsAnalogHystValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis value"
|
|
::= { ctlInternalSensorsAnalogsEntry 19 }
|
|
|
|
ctlInternalSensorsAnalogHystLowAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Alarm time"
|
|
::= { ctlInternalSensorsAnalogsEntry 20 }
|
|
|
|
ctlInternalSensorsAnalogHystLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Warning time"
|
|
::= { ctlInternalSensorsAnalogsEntry 21 }
|
|
|
|
ctlInternalSensorsAnalogHystNormal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Normal time"
|
|
::= { ctlInternalSensorsAnalogsEntry 22 }
|
|
|
|
ctlInternalSensorsAnalogHystHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Warning time"
|
|
::= { ctlInternalSensorsAnalogsEntry 23 }
|
|
|
|
ctlInternalSensorsAnalogHystHighAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Alarm time"
|
|
::= { ctlInternalSensorsAnalogsEntry 24 }
|
|
|
|
ctlInternalSensorsAnalogValueInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer value of the sensor with a multiplier of 100"
|
|
::= { ctlInternalSensorsAnalogsEntry 25 }
|
|
|
|
|
|
ctlInternalSensorsOutletsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlInternalSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctIInternalSensors 3 }
|
|
|
|
ctlInternalSensorsOutletsEntry OBJECT-TYPE
|
|
SYNTAX CtlInternalSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of outlet"
|
|
INDEX { ctlInternalSensorsOutletId }
|
|
::= { ctlInternalSensorsOutletsTable 1 }
|
|
|
|
CtlInternalSensorsOutletsEntry ::= SEQUENCE {
|
|
ctlInternalSensorsOutletId
|
|
Integer32,
|
|
ctlInternalSensorsOutletModule
|
|
Integer32,
|
|
ctlInternalSensorsOutletNum
|
|
Integer32,
|
|
ctlInternalSensorsOutletType
|
|
OCTET STRING,
|
|
ctlInternalSensorsOutletName
|
|
OCTET STRING,
|
|
ctlInternalSensorsOutletState
|
|
OCTET STRING,
|
|
ctlInternalSensorsOutletValue
|
|
OCTET STRING,
|
|
ctlInternalSensorsOutletInitial
|
|
OCTET STRING,
|
|
ctlInternalSensorsDiscretPulse
|
|
Integer32
|
|
}
|
|
|
|
ctlInternalSensorsOutletId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 1 }
|
|
|
|
ctlInternalSensorsOutletModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 2 }
|
|
|
|
ctlInternalSensorsOutletNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 3 }
|
|
|
|
ctlInternalSensorsOutletType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 4 }
|
|
|
|
ctlInternalSensorsOutletName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 5 }
|
|
|
|
ctlInternalSensorsOutletState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 6 }
|
|
|
|
ctlInternalSensorsOutletValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 7 }
|
|
|
|
ctlInternalSensorsOutletInitial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial state for outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 8 }
|
|
|
|
ctlInternalSensorsDiscretPulse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse duration for outlet"
|
|
::= { ctlInternalSensorsOutletsEntry 9 }
|
|
|
|
ctlCANSensorsDiscretsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlCANSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlCANSensors 1 }
|
|
|
|
ctlCANSensorsDiscretsEntry OBJECT-TYPE
|
|
SYNTAX CtlCANSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of discret sensor"
|
|
INDEX { ctlCANSensorsDiscretId }
|
|
::= { ctlCANSensorsDiscretsTable 1 }
|
|
|
|
CtlCANSensorsDiscretsEntry ::= SEQUENCE {
|
|
ctlCANSensorsDiscretId
|
|
Integer32,
|
|
ctlCANSensorsDiscretModule
|
|
Integer32,
|
|
ctlCANSensorsDiscretNum
|
|
Integer32,
|
|
ctlCANSensorsDiscretType
|
|
OCTET STRING,
|
|
ctlCANSensorsDiscretName
|
|
OCTET STRING,
|
|
ctlCANSensorsDiscretState
|
|
OCTET STRING,
|
|
ctlCANSensorsDiscretValue
|
|
OCTET STRING,
|
|
ctlCANSensorsDiscretReset
|
|
Integer32,
|
|
ctlCANSensorsDiscretLevel
|
|
Integer32,
|
|
ctlCANSensorsDiscretReverse
|
|
Integer32,
|
|
ctlCANSensorsDiscretSpecific
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlCANSensorsDiscretId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 1 }
|
|
|
|
ctlCANSensorsDiscretModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 2 }
|
|
|
|
ctlCANSensorsDiscretNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 3 }
|
|
|
|
ctlCANSensorsDiscretType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor's"
|
|
::= { ctlCANSensorsDiscretsEntry 4 }
|
|
|
|
ctlCANSensorsDiscretName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 5 }
|
|
|
|
ctlCANSensorsDiscretState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 6 }
|
|
|
|
ctlCANSensorsDiscretValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 7 }
|
|
|
|
ctlCANSensorsDiscretReset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 8 }
|
|
|
|
ctlCANSensorsDiscretLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 9 }
|
|
|
|
ctlCANSensorsDiscretReverse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse of sensor"
|
|
::= { ctlCANSensorsDiscretsEntry 10 }
|
|
|
|
ctlCANSensorsDiscretSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set 'reset smoke' for reset smoke detectors"
|
|
::= { ctlCANSensorsDiscretsEntry 11 }
|
|
|
|
ctlCANSensorsAnalogsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlCANSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlCANSensors 2 }
|
|
|
|
ctlCANSensorsAnalogsEntry OBJECT-TYPE
|
|
SYNTAX CtlCANSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of analog sensor"
|
|
INDEX { ctlCANSensorsAnalogId }
|
|
::= { ctlCANSensorsAnalogsTable 1 }
|
|
|
|
CtlCANSensorsAnalogsEntry ::= SEQUENCE {
|
|
ctlCANSensorsAnalogId
|
|
Integer32,
|
|
ctlCANSensorsAnalogModule
|
|
Integer32,
|
|
ctlCANSensorsAnalogNum
|
|
Integer32,
|
|
ctlCANSensorsAnalogType
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogName
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogState
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogValue
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogMin
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogMax
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogLowAlarm
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogLowWarning
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogHighWarning
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogHighAlarm
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogAt0
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogAt75
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogExpression
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogSpecific
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogHystType
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogHystValue
|
|
OCTET STRING,
|
|
ctlCANSensorsAnalogHystLowAlarm
|
|
Integer32,
|
|
ctlCANSensorsAnalogHystLowWarning
|
|
Integer32,
|
|
ctlCANSensorsAnalogHystNormal
|
|
Integer32,
|
|
ctlCANSensorsAnalogHystHighWarning
|
|
Integer32,
|
|
ctlCANSensorsAnalogHystHighAlarm
|
|
Integer32,
|
|
ctlCANSensorsAnalogValueInt
|
|
Integer32
|
|
}
|
|
|
|
ctlCANSensorsAnalogId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 1 }
|
|
|
|
ctlCANSensorsAnalogModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 2 }
|
|
|
|
-- Num in modules for mailer
|
|
|
|
ctlCANSensorsAnalogNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 3 }
|
|
|
|
ctlCANSensorsAnalogType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 4 }
|
|
|
|
ctlCANSensorsAnalogName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 5 }
|
|
|
|
ctlCANSensorsAnalogState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 6 }
|
|
|
|
ctlCANSensorsAnalogValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 7 }
|
|
|
|
ctlCANSensorsAnalogMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum of sensor value range"
|
|
::= { ctlCANSensorsAnalogsEntry 8 }
|
|
|
|
ctlCANSensorsAnalogMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum of sensor value range"
|
|
::= { ctlCANSensorsAnalogsEntry 9 }
|
|
|
|
ctlCANSensorsAnalogLowAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm level for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 10 }
|
|
|
|
ctlCANSensorsAnalogLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning level for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 11 }
|
|
|
|
ctlCANSensorsAnalogHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning level for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 12 }
|
|
|
|
ctlCANSensorsAnalogHighAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm level for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 13 }
|
|
|
|
ctlCANSensorsAnalogAt0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At0 for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 14 }
|
|
|
|
ctlCANSensorsAnalogAt75 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At75 for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 15 }
|
|
|
|
ctlCANSensorsAnalogExpression OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expression for sensor value"
|
|
::= { ctlCANSensorsAnalogsEntry 16 }
|
|
|
|
ctlCANSensorsAnalogSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlCANSensorsAnalogsEntry 17 }
|
|
|
|
ctlCANSensorsAnalogHystType OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis type"
|
|
::= { ctlCANSensorsAnalogsEntry 18 }
|
|
|
|
ctlCANSensorsAnalogHystValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis value"
|
|
::= { ctlCANSensorsAnalogsEntry 19 }
|
|
|
|
ctlCANSensorsAnalogHystLowAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Alarm time"
|
|
::= { ctlCANSensorsAnalogsEntry 20 }
|
|
|
|
ctlCANSensorsAnalogHystLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Low Warning time"
|
|
::= { ctlCANSensorsAnalogsEntry 21 }
|
|
|
|
ctlCANSensorsAnalogHystNormal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis Normal time"
|
|
::= { ctlCANSensorsAnalogsEntry 22 }
|
|
|
|
ctlCANSensorsAnalogHystHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Warning time"
|
|
::= { ctlCANSensorsAnalogsEntry 23 }
|
|
|
|
ctlCANSensorsAnalogHystHighAlarm OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hysteresis High Alarm time"
|
|
::= { ctlCANSensorsAnalogsEntry 24 }
|
|
|
|
ctlCANSensorsAnalogValueInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The integer value of the sensor with a multiplier of 100"
|
|
::= { ctlCANSensorsAnalogsEntry 25 }
|
|
|
|
|
|
ctlCANSensorsOutletsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlCANSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlCANSensors 3 }
|
|
|
|
ctlCANSensorsOutletsEntry OBJECT-TYPE
|
|
SYNTAX CtlCANSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of outlet"
|
|
INDEX { ctlCANSensorsOutletId }
|
|
::= { ctlCANSensorsOutletsTable 1 }
|
|
|
|
CtlCANSensorsOutletsEntry ::= SEQUENCE {
|
|
ctlCANSensorsOutletId
|
|
Integer32,
|
|
ctlCANSensorsOutletModule
|
|
Integer32,
|
|
ctlCANSensorsOutletNum
|
|
Integer32,
|
|
ctlCANSensorsOutletType
|
|
OCTET STRING,
|
|
ctlCANSensorsOutletName
|
|
OCTET STRING,
|
|
ctlCANSensorsOutletState
|
|
OCTET STRING,
|
|
ctlCANSensorsOutletValue
|
|
OCTET STRING,
|
|
ctlCANSensorsOutletInitial
|
|
OCTET STRING,
|
|
ctlCANSensorsDiscretPulse
|
|
Integer32
|
|
}
|
|
|
|
ctlCANSensorsOutletId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 1 }
|
|
|
|
ctlCANSensorsOutletModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 2 }
|
|
|
|
ctlCANSensorsOutletNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for outlet"
|
|
::= { ctlCANSensorsOutletsEntry 3 }
|
|
|
|
ctlCANSensorsOutletType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 4 }
|
|
|
|
ctlCANSensorsOutletName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 5 }
|
|
|
|
ctlCANSensorsOutletState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 6 }
|
|
|
|
ctlCANSensorsOutletValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of outlet"
|
|
::= { ctlCANSensorsOutletsEntry 7 }
|
|
|
|
ctlCANSensorsOutletInitial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial state for outlet"
|
|
::= { ctlCANSensorsOutletsEntry 8 }
|
|
|
|
ctlCANSensorsDiscretPulse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse duration for outlet"
|
|
::= { ctlCANSensorsOutletsEntry 9 }
|
|
|
|
ctlRsSensorsDiscretsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlRsSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlRsSensors 1 }
|
|
|
|
ctlRsSensorsDiscretsEntry OBJECT-TYPE
|
|
SYNTAX CtlRsSensorsDiscretsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of discret sensor"
|
|
INDEX { ctlRsSensorsDiscretId }
|
|
::= { ctlRsSensorsDiscretsTable 1 }
|
|
|
|
CtlRsSensorsDiscretsEntry ::= SEQUENCE {
|
|
ctlRsSensorsDiscretId
|
|
Integer32,
|
|
ctlRsSensorsDiscretModule
|
|
Integer32,
|
|
ctlRsSensorsDiscretNum
|
|
Integer32,
|
|
ctlRsSensorsDiscretType
|
|
OCTET STRING,
|
|
ctlRsSensorsDiscretName
|
|
OCTET STRING,
|
|
ctlRsSensorsDiscretState
|
|
OCTET STRING,
|
|
ctlRsSensorsDiscretValue
|
|
OCTET STRING,
|
|
ctlRsSensorsDiscretReset
|
|
Integer32,
|
|
ctlRsSensorsDiscretLevel
|
|
Integer32,
|
|
ctlRsSensorsDiscretReverse
|
|
Integer32,
|
|
ctlRsSensorsDiscretSpecific
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlRsSensorsDiscretId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 1 }
|
|
|
|
ctlRsSensorsDiscretModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 2 }
|
|
|
|
ctlRsSensorsDiscretNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 3 }
|
|
|
|
ctlRsSensorsDiscretType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor's"
|
|
::= { ctlRsSensorsDiscretsEntry 4 }
|
|
|
|
ctlRsSensorsDiscretName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 5 }
|
|
|
|
ctlRsSensorsDiscretState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 6 }
|
|
|
|
ctlRsSensorsDiscretValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 7 }
|
|
|
|
ctlRsSensorsDiscretReset OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 8 }
|
|
|
|
ctlRsSensorsDiscretLevel OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 9 }
|
|
|
|
ctlRsSensorsDiscretReverse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse of sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 10 }
|
|
|
|
ctlRsSensorsDiscretSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlRsSensorsDiscretsEntry 11 }
|
|
|
|
ctlRsSensorsAnalogsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlRsSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlRsSensors 2 }
|
|
|
|
ctlRsSensorsAnalogsEntry OBJECT-TYPE
|
|
SYNTAX CtlRsSensorsAnalogsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of analog sensor"
|
|
INDEX { ctlRsSensorsAnalogId }
|
|
::= { ctlRsSensorsAnalogsTable 1 }
|
|
|
|
CtlRsSensorsAnalogsEntry ::= SEQUENCE {
|
|
ctlRsSensorsAnalogId
|
|
Integer32,
|
|
ctlRsSensorsAnalogModule
|
|
Integer32,
|
|
ctlRsSensorsAnalogNum
|
|
Integer32,
|
|
ctlRsSensorsAnalogType
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogName
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogState
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogValue
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogMin
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogMax
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogLowAlarm
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogLowWarning
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogHighWarning
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogHighAlarm
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogAt0
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogAt75
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogExpression
|
|
OCTET STRING,
|
|
ctlRsSensorsAnalogSpecific
|
|
OCTET STRING
|
|
}
|
|
|
|
ctlRsSensorsAnalogId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 1 }
|
|
|
|
ctlRsSensorsAnalogModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 2 }
|
|
|
|
-- Num in modules for mailer
|
|
|
|
ctlRsSensorsAnalogNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 3 }
|
|
|
|
ctlRsSensorsAnalogType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 4 }
|
|
|
|
ctlRsSensorsAnalogName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 5 }
|
|
|
|
ctlRsSensorsAnalogState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 6 }
|
|
|
|
ctlRsSensorsAnalogValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 7 }
|
|
|
|
ctlRsSensorsAnalogMin OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum of sensor value range"
|
|
::= { ctlRsSensorsAnalogsEntry 8 }
|
|
|
|
ctlRsSensorsAnalogMax OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum of sensor value range"
|
|
::= { ctlRsSensorsAnalogsEntry 9 }
|
|
|
|
ctlRsSensorsAnalogLowAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low alarm level for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 10 }
|
|
|
|
ctlRsSensorsAnalogLowWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Low warning level for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 11 }
|
|
|
|
ctlRsSensorsAnalogHighWarning OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High warning level for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 12 }
|
|
|
|
ctlRsSensorsAnalogHighAlarm OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"High alarm level for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 13 }
|
|
|
|
ctlRsSensorsAnalogAt0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At0 for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 14 }
|
|
|
|
ctlRsSensorsAnalogAt75 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At75 for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 15 }
|
|
|
|
ctlRsSensorsAnalogExpression OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..80))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Expression for sensor value"
|
|
::= { ctlRsSensorsAnalogsEntry 16 }
|
|
|
|
ctlRsSensorsAnalogSpecific OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..16))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specific parameters for sensor"
|
|
::= { ctlRsSensorsAnalogsEntry 17 }
|
|
|
|
ctlRsSensorsOutletsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CtlRsSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { ctlRsSensors 3 }
|
|
|
|
ctlRsSensorsOutletsEntry OBJECT-TYPE
|
|
SYNTAX CtlRsSensorsOutletsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entry of outlet"
|
|
INDEX { ctlRsSensorsOutletId }
|
|
::= { ctlRsSensorsOutletsTable 1 }
|
|
|
|
CtlRsSensorsOutletsEntry ::= SEQUENCE {
|
|
ctlRsSensorsOutletId
|
|
Integer32,
|
|
ctlRsSensorsOutletModule
|
|
Integer32,
|
|
ctlRsSensorsOutletNum
|
|
Integer32,
|
|
ctlRsSensorsOutletType
|
|
OCTET STRING,
|
|
ctlRsSensorsOutletName
|
|
OCTET STRING,
|
|
ctlRsSensorsOutletState
|
|
OCTET STRING,
|
|
ctlRsSensorsOutletValue
|
|
OCTET STRING,
|
|
ctlRsSensorsOutletInitial
|
|
OCTET STRING,
|
|
ctlRsSensorsDiscretPulse
|
|
Integer32
|
|
}
|
|
|
|
ctlRsSensorsOutletId OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Id of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 1 }
|
|
|
|
ctlRsSensorsOutletModule OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 2 }
|
|
|
|
ctlRsSensorsOutletNum OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical number in module for outlet"
|
|
::= { ctlRsSensorsOutletsEntry 3 }
|
|
|
|
ctlRsSensorsOutletType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 4 }
|
|
|
|
ctlRsSensorsOutletName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(2..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 5 }
|
|
|
|
ctlRsSensorsOutletState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"State of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 6 }
|
|
|
|
ctlRsSensorsOutletValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of outlet"
|
|
::= { ctlRsSensorsOutletsEntry 7 }
|
|
|
|
ctlRsSensorsOutletInitial OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial state for outlet"
|
|
::= { ctlRsSensorsOutletsEntry 8 }
|
|
|
|
ctlRsSensorsDiscretPulse OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Pulse duration for outlet"
|
|
::= { ctlRsSensorsOutletsEntry 9 }
|
|
|
|
END
|
|
|
|
|