-- Transition Networks sFlow MIB
--
-- Copyright (C) 2012 Transition Networks, Inc. All Rights Reserved.
-- *****************************************************************
TN-S-FLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString, RowStatus, TruthValue
FROM SNMPv2-TC
InetAddressType, InetAddress
FROM INET-ADDRESS-MIB
MODULE-IDENTITY,
OBJECT-IDENTITY,
enterprises, IpAddress, Unsigned32 FROM SNMPv2-SMI
entPhysicalIndex FROM ENTITY-MIB
ifIndex FROM IF-MIB
tnProducts FROM TRANSITION-SMI;
tnSFlowMIB MODULE-IDENTITY
LAST-UPDATED "201210100000Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The mib module is designed for S Flow."
::= { tnProducts 119 }
tnSFlowMIBObjects
OBJECT IDENTIFIER ::= { tnSFlowMIB 1 }
--
-- MIB variables
--
tnSFlowMIBMgmt
OBJECT IDENTIFIER ::= { tnSFlowMIBObjects 1 }
--
-- tnSFlowReceiverConfigTable
--
tnSFlowReceiverConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNSFlowReceiverConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains sFlow receiver configuration."
::= { tnSFlowMIBMgmt 1 }
tnSFlowReceiverConfigEntry OBJECT-TYPE
SYNTAX TNSFlowReceiverConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents the sFlow receiver configuration on a device."
INDEX { entPhysicalIndex }
::= { tnSFlowReceiverConfigTable 1 }
TNSFlowReceiverConfigEntry ::= SEQUENCE {
tnSFlowReceiverOwner DisplayString,
tnSFlowReceiverRelease TruthValue,
tnSFlowReceiverAddressType InetAddressType,
tnSFlowReceiverAddress InetAddress,
tnSFlowReceiverUDPPort INTEGER,
tnSFlowReceiverTimeout Unsigned32,
tnSFlowReceiverMaxDatagramSize INTEGER
}
tnSFlowReceiverOwner OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Represents the owner of the SFlow Receiver configuration."
::= { tnSFlowReceiverConfigEntry 1 }
tnSFlowReceiverRelease OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "True for releasing the owner of the SFlow Receiver configuration."
::= { tnSFlowReceiverConfigEntry 2 }
tnSFlowReceiverAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The address type of SFlow Receiver.
For a detailed description of this type, please refer to INET-ADDRESS-MIB."
::= { tnSFlowReceiverConfigEntry 3 }
tnSFlowReceiverAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Address of SFlow Receiver.
For a detailed description of this type, please refer to INET-ADDRESS-MIB."
::= { tnSFlowReceiverConfigEntry 4 }
tnSFlowReceiverUDPPort OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The UDP Port number of SFlow Receiver."
::= { tnSFlowReceiverConfigEntry 5 }
tnSFlowReceiverTimeout OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Timeout (seconds) of SFlow Receiver."
::= { tnSFlowReceiverConfigEntry 6 }
tnSFlowReceiverMaxDatagramSize OBJECT-TYPE
SYNTAX INTEGER (200..1468)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Maximum datagram size (bytes) of SFlow Receiver."
::= { tnSFlowReceiverConfigEntry 7 }
---
--- tnSFlowPortConfigTable
---
tnSFlowPortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNSFlowPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the configuration of SFlow flow sample and counter sample on ports."
::= { tnSFlowMIBMgmt 2 }
tnSFlowPortConfigEntry OBJECT-TYPE
SYNTAX TNSFlowPortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents the configuration of SFlow flow sample and counter sample on a port."
INDEX { ifIndex }
::= { tnSFlowPortConfigTable 1 }
TNSFlowPortConfigEntry ::= SEQUENCE {
tnSFlowSamplerEnabled TruthValue,
tnSFlowFlowRate Unsigned32,
tnSFlowFlowMaxHeader INTEGER,
tnSFlowCounterEnabled TruthValue,
tnSFlowCounterInteval INTEGER
}
tnSFlowSamplerEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Enable or disable the SFlow Sampler on a port."
::= { tnSFlowPortConfigEntry 1 }
tnSFlowFlowRate OBJECT-TYPE
SYNTAX Unsigned32 (1..4294967295)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Sampling flow rate of the SFlow on a port."
::= { tnSFlowPortConfigEntry 2 }
tnSFlowFlowMaxHeader OBJECT-TYPE
SYNTAX INTEGER (14..200)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The sample flow max header of the SFlow on a port."
::= { tnSFlowPortConfigEntry 3 }
tnSFlowCounterEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To Enable or disable the SFlow counter poller on a port."
::= { tnSFlowPortConfigEntry 4 }
tnSFlowCounterInteval OBJECT-TYPE
SYNTAX INTEGER (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The flow counter interval of the SFlow on a port."
::= { tnSFlowPortConfigEntry 5 }
---
--- tnSFlowReceiverStatisticsTable
---
tnSFlowReceiverStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNSFlowReceiverStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the receiver statistics of SFlow."
::= { tnSFlowMIBMgmt 3 }
tnSFlowReceiverStatisticsEntry OBJECT-TYPE
SYNTAX TNSFlowReceiverStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents a receiver statistics of SFlow"
INDEX { entPhysicalIndex }
::= { tnSFlowReceiverStatisticsTable 1 }
TNSFlowReceiverStatisticsEntry ::= SEQUENCE {
tnSFlowReceiverTxSuccesses Unsigned32,
tnSFlowReceiverTxErrors Unsigned32,
tnSFlowReceiverFlowSamples Unsigned32,
tnSFlowReceiverCounterSamples Unsigned32,
tnSFlowClearReceiverStatistics TruthValue
}
tnSFlowReceiverTxSuccesses OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Tx successes statistic of the SFlow receiver."
::= { tnSFlowReceiverStatisticsEntry 1 }
tnSFlowReceiverTxErrors OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Tx errors statistic of the SFlow receiver."
::= { tnSFlowReceiverStatisticsEntry 2 }
tnSFlowReceiverFlowSamples OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The flow samples statistic of the SFlow receiver."
::= { tnSFlowReceiverStatisticsEntry 3 }
tnSFlowReceiverCounterSamples OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The counter samples statistic of the SFlow receiver."
::= { tnSFlowReceiverStatisticsEntry 4 }
tnSFlowClearReceiverStatistics OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "True for clearing statistics of the SFlow receiver."
::= { tnSFlowReceiverStatisticsEntry 5 }
---
--- tnSFlowPortStatisticsTable
---
tnSFlowPortStatisticsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TNSFlowPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the port statistics of SFlow."
::= { tnSFlowMIBMgmt 4 }
tnSFlowPortStatisticsEntry OBJECT-TYPE
SYNTAX TNSFlowPortStatisticsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents a port statistics of SFlow"
INDEX { ifIndex }
::= { tnSFlowPortStatisticsTable 1 }
TNSFlowPortStatisticsEntry ::= SEQUENCE {
tnSFlowRxSamples Unsigned32,
tnSFlowTxSamples Unsigned32,
tnSFlowCounterSamples Unsigned32,
tnSFlowClearPortsStatistics TruthValue
}
tnSFlowRxSamples OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Rx samples of the SFlow on a port."
::= { tnSFlowPortStatisticsEntry 1 }
tnSFlowTxSamples OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Tx samples of the SFlow on a port."
::= { tnSFlowPortStatisticsEntry 2 }
tnSFlowCounterSamples OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Counter samples of the SFlow on a port."
::= { tnSFlowPortStatisticsEntry 3 }
tnSFlowClearPortsStatistics OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "True for clearing statistics of the SFlow on all ports."
::= { tnSFlowPortStatisticsEntry 4 }
END