-- TN-LOOP-PROTECT-MIB.my : TN Loop Protection MIB
--
-- Copyright (c) 2012 by Transition Networks, Inc.
-- All rights reserved.
--
-- *****************************************************************
TN-LOOP-PROTECT-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP FROM SNMPv2-CONF
entPhysicalIndex FROM ENTITY-MIB
ifIndex FROM IF-MIB
TruthValue, TimeStamp, DateAndTime, DisplayString
FROM SNMPv2-TC
tnProducts FROM TRANSITION-SMI;
tnLoopProtectMIB MODULE-IDENTITY
LAST-UPDATED "201207251030Z"
ORGANIZATION "Transition Networks, Inc."
CONTACT-INFO
"Transition Networks
Technical Support
10900 Red Circle Drive
Minnetonka, MN 55343 USA
Tel: +1-800-526-9267
E-mail: techsupport@transition.com"
DESCRIPTION
"The mib module for managing all transition products with Loop protection"
REVISION "201207251030Z"
DESCRIPTION
"Initial version of this MIB module."
::= { tnProducts 22 }
tnLoopProtectNotifications OBJECT IDENTIFIER ::= { tnLoopProtectMIB 0 }
tnLoopProtectObjects OBJECT IDENTIFIER ::= { tnLoopProtectMIB 1 }
tnLoopProtectLoopDetectedNotification NOTIFICATION-TYPE
OBJECTS { ifIndex,
tnLoopProtectPortLoopCount,
tnLoopProtectPortAction}
STATUS current
DESCRIPTION
"A tnLoopProtectLoopDetectedNotification signifies
that a loop has been detected by the loop protection protocol.
Additional infomation contains port number ,count of loop detected on the port
and the action will be execute"
::= { tnLoopProtectNotifications 1 }
tnLoopProtectMgmt OBJECT IDENTIFIER ::= { tnLoopProtectObjects 1 }
tnLoopProtectBaseTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnLoopProtectBaseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used for configuring global loop protect variables"
::= { tnLoopProtectMgmt 1 }
tnLoopProtectBaseEntry OBJECT-TYPE
SYNTAX TnLoopProtectBaseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains configuration elements of tnLoopProtectBaseTable"
INDEX { entPhysicalIndex }
::= { tnLoopProtectBaseTable 1 }
TnLoopProtectBaseEntry ::= SEQUENCE {
tnLoopProtectEnable TruthValue,
tnLoopProtectTxTime INTEGER,
tnLoopProtectShutdownTime INTEGER
}
tnLoopProtectEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether the loop protect is enable on this device."
::= { tnLoopProtectBaseEntry 1 }
tnLoopProtectTxTime OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interval in seconds between each loop protection PDU sent on each port.
valid values are 1 to 10 seconds,the default value is 5 seconds."
::= { tnLoopProtectBaseEntry 2 }
tnLoopProtectShutdownTime OBJECT-TYPE
SYNTAX INTEGER (0..604800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The period (in seconds) for which a port will be kept disabled in the event of a loop is detected (and the port action shuts down the port).
Valid values are 0 to 604800 seconds (7 days). A value of zero will keep a port disabled (until next device restart)."
::= { tnLoopProtectBaseEntry 3 }
tnLoopProtectPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TnLoopProtectPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is used for configuring loop protect options for each port"
::= { tnLoopProtectMgmt 2 }
tnLoopProtectPortEntry OBJECT-TYPE
SYNTAX TnLoopProtectPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains configuration element of tnLoopProtectBaseTable"
INDEX { ifIndex }
::= { tnLoopProtectPortTable 1 }
TnLoopProtectPortEntry ::= SEQUENCE {
tnLoopProtectPortEnable TruthValue,
tnLoopProtectPortAction INTEGER,
tnLoopProtectPortTxModeEnable TruthValue,
tnLoopProtectPortLoopCount Counter32,
tnLoopProtectPortStatus INTEGER,
tnLoopProtectPortLoopDetected TruthValue,
tnLoopProtectPortLastLoopTime DateAndTime
}
tnLoopProtectPortEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether loop protection is enabled on this switch port."
::= {tnLoopProtectPortEntry 1}
tnLoopProtectPortAction OBJECT-TYPE
SYNTAX INTEGER {shutdown(1),shutdownAndlog(2),log(3),trap(4),shutdownAndtrap(5),logAndtrap(6),all(7)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Configures the action performed when a loop is detected on a port. Valid values are Shutdown Port(1), Shutdown Port and Log(2) or Log Only(3)."
::= { tnLoopProtectPortEntry 2 }
tnLoopProtectPortTxModeEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls whether the port is actively generating loop protection PDU's, or whether it is just passively looking for looped PDU's."
::= { tnLoopProtectPortEntry 3 }
tnLoopProtectPortLoopCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of loops detected on this port."
::= { tnLoopProtectPortEntry 4 }
tnLoopProtectPortStatus OBJECT-TYPE
SYNTAX INTEGER{up(1),down(2),disable(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the port.
up(1): the status of the port is up.
down(2):the status of the port is down.
disable(3):loop is detected in this port and shutdown is triggered at the same time"
::= { tnLoopProtectPortEntry 5 }
tnLoopProtectPortLoopDetected OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates Whether a loop is currently detected on the port."
::= { tnLoopProtectPortEntry 6 }
tnLoopProtectPortLastLoopTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of the last loop event detected."
::= { tnLoopProtectPortEntry 7 }
END