- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1055 lines
29 KiB
Text
1055 lines
29 KiB
Text
ULAF2-MIB DEFINITIONS ::= BEGIN
|
|
--------------------------------------------------------------------------------
|
|
-- The lineintegrator MIB
|
|
-- ______________
|
|
--
|
|
-- 1. Introduction
|
|
-- This document defines the enterprise specific MIB for the LineIntegrater,
|
|
-- which provides the management of the ULAF-2 transmission family.
|
|
-- The MIB is divided into three basic MIBs
|
|
-- proxyAgent MIB
|
|
-- device MIB
|
|
-- links MIB
|
|
--
|
|
-- 2. The proxyAgent MIB
|
|
-- _____________________
|
|
--
|
|
-- The proxyAgent MIB consists of a table with information about the
|
|
-- supervised serial ports and the connected devices. Either an OMI
|
|
-- equipment or a NAG-2D.x can be connected.
|
|
--
|
|
--
|
|
-- 3. The device MIB
|
|
-- _________________
|
|
--
|
|
-- The device MIB is a table, where each entry refers to a line card slot.
|
|
-- It contains the name of the inserted cards and a alarm attribute, which
|
|
-- is used to send SNMP traps to the manager, if a link goes down.
|
|
--
|
|
-- 5. The links MIB
|
|
-- _____________________
|
|
--
|
|
-- The links MIB consists of several tables, which contain detailed
|
|
-- management information about the line cards.
|
|
-- The links MIB is divided into three parts
|
|
-- link
|
|
-- near
|
|
-- far
|
|
-- The near part contains only configuration information about the line
|
|
-- card.
|
|
-- The link part is separated into configuration, performance ,fault
|
|
-- management and alarm management. In addition the performance part contains
|
|
-- a table about attenuation and error estimation of HDSL links (hdslTable).
|
|
--
|
|
-- 16.12.96 Urs Aebersold, Siemens Switzerland Ltd.
|
|
--------------------------------------------------------------------------------
|
|
|
|
IMPORTS
|
|
enterprises, NetworkAddress, IpAddress, Counter, Gauge,
|
|
TimeTicks
|
|
FROM RFC1155-SMI
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
siemensCH OBJECT IDENTIFIER ::= { enterprises 1887 }
|
|
|
|
lineintegrator OBJECT IDENTIFIER ::= { siemensCH 1 }
|
|
|
|
ulaf2 OBJECT IDENTIFIER ::= { lineintegrator 1 }
|
|
|
|
proxyAgent OBJECT IDENTIFIER ::= { ulaf2 1 }
|
|
|
|
proxyAgtVers2 OBJECT IDENTIFIER ::= { proxyAgent 2 }
|
|
|
|
device OBJECT IDENTIFIER ::= { ulaf2 3 }
|
|
|
|
links OBJECT IDENTIFIER ::= { ulaf2 4 }
|
|
|
|
linksVers2 OBJECT IDENTIFIER ::= { links 2 }
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtSystem OBJECT IDENTIFIER ::= { proxyAgtVers2 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtSWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains software version of Proxy Subagent."
|
|
::= { agtSystem 1 }
|
|
|
|
agtDateLastPortChange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains time when the connected device or the type of link of a device
|
|
equipment has changed.(Link Up and Down traps)."
|
|
::= { agtSystem 2 }
|
|
|
|
agtProxyFeatureFlag OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(33))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains a map of features supported by the local device.
|
|
Byte 0-31 contain the bit-coded feature flags 0..255
|
|
Byte 32 contains information about the validity of the
|
|
previous 32 bytes.
|
|
1 Ok The information in bytes 0..31 is valid
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { agtSystem 3 }
|
|
|
|
agtProxyAciSupported OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies this device as Ulaf+ OMI SNMP towards
|
|
Access Integrator. Always returns 'FullAciSupport'"
|
|
::= { agtSystem 4 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtSerialPort OBJECT IDENTIFIER ::= { proxyAgtVers2 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the number of available serial ports"
|
|
::= { agtSerialPort 1 }
|
|
|
|
agtPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AgtPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { agtSerialPort 2 }
|
|
|
|
agtPortEntry OBJECT-TYPE
|
|
SYNTAX AgtPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { agtPortIndex }
|
|
::= { agtPortTable 1 }
|
|
|
|
AgtPortEntry ::=
|
|
SEQUENCE
|
|
{
|
|
agtPortIndex INTEGER,
|
|
agtPortName DisplayString,
|
|
agtPortConnected INTEGER,
|
|
agtConnectedDevice DisplayString,
|
|
agtPortType INTEGER,
|
|
agtPortTypeNumber INTEGER,
|
|
agtPortServerName DisplayString,
|
|
agtPortState INTEGER,
|
|
agtPortDeviceFamily INTEGER,
|
|
agtPortTryingDevice INTEGER
|
|
}
|
|
|
|
agtPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object corresponds to the port number. Ports are
|
|
enumarated beginning with one."
|
|
::= { agtPortEntry 1 }
|
|
|
|
agtPortName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains name of device file"
|
|
::= { agtPortEntry 2 }
|
|
|
|
|
|
agtPortConnected OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no(1),
|
|
yes(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object tells the agent, if the appropriate serial port
|
|
is used or not."
|
|
::= { agtPortEntry 3 }
|
|
|
|
|
|
agtConnectedDevice OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the name of the connected device (e.g OMIBG)."
|
|
::= { agtPortEntry 4 }
|
|
|
|
agtPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
local(1),
|
|
portType(2),
|
|
portServer(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object describes if the port is a local RS232 serial port,
|
|
a locally installed serial port card or the port is a remote
|
|
port of a port server"
|
|
::= { agtPortEntry 5 }
|
|
|
|
agtPortTypeNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the number of the serial port of the
|
|
appropriate port type defined in agtPortType."
|
|
::= { agtPortEntry 6 }
|
|
|
|
agtPortServerName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains a name to identify the port server"
|
|
::= { agtPortEntry 7 }
|
|
|
|
agtPortState OBJECT-TYPE
|
|
------------------------------------
|
|
-- new in V3.0
|
|
------------------------------------
|
|
SYNTAX INTEGER
|
|
{
|
|
unopenedSerial(1),
|
|
openedSerial(2),
|
|
connectingRemote(3),
|
|
openedRemote(4),
|
|
failedRemote(5),
|
|
disabled(6),
|
|
invalid(7),
|
|
unknown(254)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable shows in which reconnection state a port is.
|
|
The first two states refer to local serial ports or to
|
|
PortServer ports using the Digi RealPort drivers, the last
|
|
three states refer to PortServer ports using the
|
|
proprietory method of LineIntegrator.
|
|
1 UnopenedSerial Serial port, not opened
|
|
2 OpenedSerial Serial port, opened
|
|
3 ConnectingRemote Remote port, waiting for connection
|
|
4 OpenedRemote Remote port, opened
|
|
5 FailedRemote Remote port, connection failed
|
|
6 Disabled Port is disabled
|
|
7 Invalid Port entry is invalid (configuration file problem)
|
|
254 Unknown Unknown value"
|
|
::= { agtPortEntry 8 }
|
|
|
|
agtPortDeviceFamily OBJECT-TYPE
|
|
------------------------------------
|
|
-- new in V3.0
|
|
------------------------------------
|
|
SYNTAX INTEGER
|
|
{
|
|
ulaf2(1),
|
|
ulafPlus(2),
|
|
ulaf2AndPlus(3),
|
|
unknown(254)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable shows which device family will be tried during
|
|
the auto-discovery phase.
|
|
1 Ulaf2 Ulaf-2 Devices (OMI, NAG) will be discovered
|
|
2 UlafPlus Ulaf+ Devices (OMI, XTU) will be discovered
|
|
3 Ulaf2AndPlus Ulaf-2 and Ulaf+ devices will be discovered
|
|
254 Unknown Unknown value"
|
|
::= { agtPortEntry 9 }
|
|
|
|
|
|
agtPortTryingDevice OBJECT-TYPE
|
|
------------------------------------
|
|
-- new in V3.0
|
|
------------------------------------
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled(1),
|
|
invalid(2),
|
|
none(3),
|
|
omi(4),
|
|
nag(5),
|
|
omiPlus(6),
|
|
desktopPlus(7),
|
|
unknown(254)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable shows which device is currently being tried on the port.
|
|
If no answer is received during 5 seconds, the next device will be tried
|
|
1 Disabled The port has been disabled, no device will be tried
|
|
2 Invalid The port is invalid, no device will be tried
|
|
3 None No device is being tried at the moment
|
|
4 Omi Trying Ulaf-2 OMI
|
|
5 Nag Trying Ulaf-2 NAG Desktop
|
|
6 OmiPlus Trying Ulaf+ OMI
|
|
7 DesktopPlus Trying Ulaf+ Desktop
|
|
254 Unknown Unknown value"
|
|
::= { agtPortEntry 10 }
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtAlarmCountGroup OBJECT IDENTIFIER ::= { proxyAgtVers2 3 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
agtAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object counts the number of Alarm traps
|
|
sent by this proxy since the last time the
|
|
variable has been read."
|
|
::= { agtAlarmCountGroup 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
agtPortServerReset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
reset(1),
|
|
unknown(254)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable cannot be read (it returns unknown if read)
|
|
If reset(1) is written to it, the proxy tries to reset all
|
|
DigiInternational PortServers. It does not reset any other
|
|
manufacturer's port servers.
|
|
|
|
This step can be necessary, if a router between the proxy
|
|
and a PortServer has crashed and the PortServer keeps open
|
|
a stale connection to which the proxy can no longer connect.
|
|
|
|
Do not use this feature manually but use the option in the
|
|
LineIntegrator Menu in HP OpenView NNM."
|
|
::= { proxyAgtVers2 4 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
|
|
|
|
-------------------------------------------------------------------------------
|
|
--
|
|
-- { COMMENTED OUT THIS SECTION, bee, 30-11-2000
|
|
--
|
|
-- This section has been deactivated after having been tested
|
|
-- the proxy supports these variables in principle but as the
|
|
-- OMI SNMP does not yet support them, this section of the
|
|
-- mib has been commented out. furthermore the corresponding
|
|
-- support in the proxy is beeing suppressed in the undefs.h
|
|
-- file.
|
|
--
|
|
-- to reactivate the section, you need to
|
|
-- - remove the undef lines from ~/work/proxy/src/undefs.h
|
|
-- - remove the minus (-) signs at the beginning of this
|
|
-- block (the curly bracket on the first comment line
|
|
-- is conveniently matched with a comment block at the
|
|
-- end, so Ctrl-G in Joe should jump between them)
|
|
--
|
|
-------------------------------------------------------------------------------
|
|
|
|
-------------------------------------------------------------------------------
|
|
-- agtOmiSnmpIpData OBJECT IDENTIFIER ::= { proxyAgtVers2 5 }
|
|
--
|
|
-------------------------------------------------------------------------------
|
|
--agtOmiSnmpIpDataMacAddress OBJECT-TYPE
|
|
-- SYNTAX OCTET STRING (SIZE(6))
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Returns the 6 bytes of the OMI SNMP's or Proxy's
|
|
-- MAC Address"
|
|
-- ::= { agtOmiSnmpIpData 1 }
|
|
--
|
|
--agtOmiSnmpIpDataIpAddress OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
|
|
-- IP Address"
|
|
-- ::= { agtOmiSnmpIpData 2 }
|
|
--
|
|
--agtOmiSnmpIpDataSubnetMask OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
|
|
-- Subnet Mask"
|
|
-- ::= { agtOmiSnmpIpData 3 }
|
|
--
|
|
--agtOmiSnmpIpDataDefaultRouter OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
|
|
-- Default Router IP Address"
|
|
-- ::= { agtOmiSnmpIpData 4 }
|
|
--
|
|
--agtOmiSnmpIpDataTrapDestNumber OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Contains the number of entries in the
|
|
-- Trap Destination Table"
|
|
-- ::= { agtOmiSnmpIpData 5 }
|
|
--
|
|
--agtOmiSnmpIpDataTrapDestTable OBJECT-TYPE
|
|
-- SYNTAX SEQUENCE OF AgtOmiSnmpIpDataTrapDestEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Contains the IP Settings of the OMI SNMP"
|
|
-- ::= { agtOmiSnmpIpData 6 }
|
|
--
|
|
--agtOmiSnmpIpDataTrapDestEntry OBJECT-TYPE
|
|
-- SYNTAX AgtOmiSnmpIpDataTrapDestEntry
|
|
-- ACCESS not-accessible
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Contains the IP Settings of the OMI SNMP"
|
|
-- INDEX { agtOmiSnmpIpDataTrapDestIndex }
|
|
-- ::= { agtOmiSnmpIpDataTrapDestTable 1 }
|
|
--
|
|
--AgtOmiSnmpIpDataTrapDestEntry ::=
|
|
-- SEQUENCE
|
|
-- {
|
|
-- agtOmiSnmpIpDataTrapDestIndex INTEGER,
|
|
-- agtOmiSnmpIpDataTrapDestAddress OCTET STRING
|
|
-- }
|
|
--
|
|
--agtOmiSnmpIpDataTrapDestIndex OBJECT-TYPE
|
|
-- SYNTAX INTEGER
|
|
-- ACCESS read-only
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Index to the Trap Destinations"
|
|
-- ::= { agtOmiSnmpIpDataTrapDestEntry 1 }
|
|
--
|
|
--agtOmiSnmpIpDataTrapDestAddress OBJECT-TYPE
|
|
-- SYNTAX IpAddress
|
|
-- ACCESS read-write
|
|
-- STATUS mandatory
|
|
-- DESCRIPTION
|
|
-- "Returns the 4 bytes of the OMI SNMP's or Proxy's
|
|
-- Trap Destinations"
|
|
-- ::= { agtOmiSnmpIpDataTrapDestEntry 2 }
|
|
--
|
|
------------------------------------------------------------------------------
|
|
--
|
|
-- END OF COMMENTED OUT SECTION, bee, 30-11-2000 }
|
|
--
|
|
------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
deviceVers2 OBJECT IDENTIFIER ::= { device 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
|
|
--------------------------------------------------------------------------------
|
|
deviceSystem OBJECT IDENTIFIER ::= { deviceVers2 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
|
|
deviceSystemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceSystemEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { deviceSystem 1 }
|
|
|
|
deviceSystemEntry OBJECT-TYPE
|
|
SYNTAX DeviceSystemEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { deviceSystemPortIndex }
|
|
::= { deviceSystemTable 1 }
|
|
|
|
DeviceSystemEntry ::=
|
|
SEQUENCE
|
|
{
|
|
deviceSystemPortIndex INTEGER,
|
|
deviceLinkNumber INTEGER,
|
|
deviceSWVersion DisplayString,
|
|
deviceExtAlarm INTEGER,
|
|
deviceDateLastLinkChange INTEGER,
|
|
deviceOmiFeatureFlag OCTET STRING
|
|
}
|
|
|
|
deviceSystemPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object addresses the port of the proxy agent."
|
|
::= { deviceSystemEntry 1 }
|
|
|
|
deviceLinkNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the maximum number of supported line cards "
|
|
::= { deviceSystemEntry 2 }
|
|
|
|
|
|
deviceSWVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains software version of device."
|
|
::= { deviceSystemEntry 3 }
|
|
|
|
deviceExtAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAlarm(1),
|
|
urgent(2),
|
|
notUrgent(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the external alarm of the OMI equipment."
|
|
::= { deviceSystemEntry 4 }
|
|
|
|
deviceDateLastLinkChange OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the absolute date and time when the type
|
|
of link has changed its configuration.
|
|
(e.g. removing a line card).
|
|
(Link Up and Link Down Traps)"
|
|
::= { deviceSystemEntry 5 }
|
|
|
|
deviceOmiFeatureFlag OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(33))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains a map of features supported by the local device.
|
|
Byte 0-31 contain the bit-coded feature flags 0..255
|
|
Byte 32 contains information about the validity of the
|
|
previous 32 bytes.
|
|
1 Ok The information in bytes 0..31 is valid
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceSystemEntry 6 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
deviceLinks OBJECT IDENTIFIER ::= { deviceVers2 2 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
|
|
|
|
deviceLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DeviceLinkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { deviceLinks 1 }
|
|
|
|
deviceLinkEntry OBJECT-TYPE
|
|
SYNTAX DeviceLinkEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { devicePortIndex, deviceLinkIndex }
|
|
::= { deviceLinkTable 1 }
|
|
|
|
DeviceLinkEntry ::=
|
|
SEQUENCE
|
|
{
|
|
devicePortIndex
|
|
INTEGER,
|
|
deviceLinkIndex
|
|
INTEGER,
|
|
deviceLinkName
|
|
DisplayString,
|
|
deviceLinkAlarm
|
|
INTEGER,
|
|
-------------------------------
|
|
-- added in V3.0
|
|
-------------------------------
|
|
deviceLinkLocalLtNt INTEGER,
|
|
deviceLinkLocalId DisplayString,
|
|
deviceLinkFarId DisplayString,
|
|
deviceLinkNumReg1 INTEGER,
|
|
deviceLinkNumReg2 INTEGER,
|
|
deviceLinkLocalModules INTEGER,
|
|
deviceLinkFarModules INTEGER,
|
|
deviceLinkLocalHwFabData DisplayString,
|
|
deviceLinkFarHwFabData DisplayString,
|
|
deviceLinkLocalG703FabData DisplayString,
|
|
deviceLinkLocalDataFabData DisplayString,
|
|
-------------------------------
|
|
-- added in V3.1
|
|
-------------------------------
|
|
deviceLinkLocalFeatureFlag OCTET STRING,
|
|
deviceLinkFarFeatureFlag OCTET STRING,
|
|
deviceLinkFarFeatureFlagState INTEGER,
|
|
-------------------------------
|
|
-- added in V3.4
|
|
-------------------------------
|
|
deviceLinkSruFeatureFlag OCTET STRING,
|
|
|
|
deviceLinkNumReg3 INTEGER,
|
|
deviceLinkNumReg4 INTEGER
|
|
}
|
|
|
|
devicePortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object addresses the port of the proxy agent."
|
|
::= { deviceLinkEntry 1 }
|
|
|
|
deviceLinkIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object addresses the links."
|
|
::= { deviceLinkEntry 2 }
|
|
|
|
deviceLinkName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the name of the inserted line card.
|
|
If no line card exists, the name is Unknown."
|
|
::= { deviceLinkEntry 3 }
|
|
|
|
deviceLinkAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object contains the collected alarms
|
|
It is used to convert alarm notifications
|
|
to SNMP traps.
|
|
|
|
Bits 0,1 and 2 are used for the Alarm Summary
|
|
Bit 5 is used to signify a loop state change of Ulaf-2 Desktop devices
|
|
|
|
Bit Alarm Description
|
|
|
|
0 UA Urgent alarm
|
|
1 NUA Non urgent alarm
|
|
2 AIS Alarm indication signal
|
|
3 unused
|
|
4 unused
|
|
5 loopback change (Ulaf-2)
|
|
|
|
"
|
|
|
|
::= { deviceLinkEntry 4 }
|
|
|
|
-------------------------------
|
|
-- added in V3.0
|
|
-------------------------------
|
|
deviceLinkLocalLtNt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
lt(1),
|
|
nt(2),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates whether the management system is connected to
|
|
an LT or an NT device.
|
|
1 LT Device is configured as LT
|
|
2 NT Device is configured as NT (NT local)
|
|
254 unknown value
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceLinkEntry 5 }
|
|
|
|
deviceLinkLocalId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Firmware ID of the local device."
|
|
::= { deviceLinkEntry 6 }
|
|
|
|
deviceLinkFarId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Firmware ID of the far device."
|
|
::= { deviceLinkEntry 7 }
|
|
|
|
deviceLinkNumReg1 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
one(2),
|
|
two(3),
|
|
three(4),
|
|
four(5),
|
|
five(6),
|
|
six(7),
|
|
seven(8),
|
|
eight(9),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates how many regenerators were detected in HDSL path 1.
|
|
1 None No regenerator found
|
|
2 One One regenerator found (section A or 1)
|
|
3 Two Two regenerators found (section B or 2)
|
|
4 Three Three regenerators found (section 3)
|
|
5 Four Four regenerators found (section 4)
|
|
6 Five Five regenerators found (section 5)
|
|
7 Six Six regenerators found (section 6)
|
|
8 Seven Seven regenerators found (section 7)
|
|
9 Eight Eight regenerators found (section 8)
|
|
254 unknown value
|
|
255 unsupported value"
|
|
::= { deviceLinkEntry 8 }
|
|
|
|
deviceLinkNumReg2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
one(2),
|
|
two(3),
|
|
three(4),
|
|
four(5),
|
|
five(6),
|
|
six(7),
|
|
seven(8),
|
|
eight(9),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates how many regenerators were detected in HDSL path 1.
|
|
1 None No regenerator found
|
|
2 One One regenerator found (section A or 1)
|
|
3 Two Two regenerators found (section B or 2)
|
|
4 Three Three regenerators found (section 3)
|
|
5 Four Four regenerators found (section 4)
|
|
6 Five Five regenerators found (section 5)
|
|
7 Six Six regenerators found (section 6)
|
|
8 Seven Seven regenerators found (section 7)
|
|
9 Eight Eight regenerators found (section 8)
|
|
254 unknown value
|
|
255 unsupported value"
|
|
::= { deviceLinkEntry 9 }
|
|
|
|
deviceLinkLocalModules OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gives a short summary of which modules are installed in the local
|
|
device. This variable is bit coded as follows:
|
|
Bit 0 G.703 Interface installed
|
|
Bit 1 Data Interface installed
|
|
Bit 2 Alarm Module installed
|
|
Bit 3 Clock Module installed
|
|
Bit 4 Debug Module installed
|
|
Bit 5 Rps Module installed
|
|
Bit 6 unknown value (ignore bits 0-5)
|
|
Bit 7 unsupported value (ignore bits 0-5)"
|
|
::= { deviceLinkEntry 10 }
|
|
|
|
deviceLinkFarModules OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gives a short summary of which modules are installed in the far
|
|
device. This variable is bit coded as follows:
|
|
Bit 0 G.703 Interface installed
|
|
Bit 1 Data Interface installed
|
|
Bit 2 Alarm Module installed
|
|
Bit 3 Clock Module installed
|
|
Bit 4 Debug Module installed
|
|
Bit 5 Rps Module installed
|
|
Bit 6 unknown value (ignore bits 0-5)
|
|
Bit 7 unsupported value (ignore bits 0-5)"
|
|
::= { deviceLinkEntry 11 }
|
|
|
|
deviceLinkLocalHwFabData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Mainboard fabrication data of the local device."
|
|
::= { deviceLinkEntry 12 }
|
|
|
|
deviceLinkFarHwFabData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Mainboard fabrication data of the far device."
|
|
::= { deviceLinkEntry 13 }
|
|
|
|
deviceLinkLocalG703FabData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the G703 Module fabrication data of the local device."
|
|
::= { deviceLinkEntry 14 }
|
|
|
|
deviceLinkLocalDataFabData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains the Data Module fabrication data of the local device."
|
|
::= { deviceLinkEntry 15 }
|
|
|
|
-------------------------------
|
|
-- added in V3.0
|
|
-------------------------------
|
|
|
|
deviceLinkLocalFeatureFlag OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(33))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains a map of features supported by the local device.
|
|
Byte 0-31 contain the bit-coded feature flags 0..255
|
|
Byte 32 contains information about the validity of the
|
|
previous 32 bytes.
|
|
1 Ok The information in bytes 0..31 is valid
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceLinkEntry 16 }
|
|
|
|
deviceLinkFarFeatureFlag OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(33))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains a map of features supported by the local device.
|
|
Byte 0-31 contain the bit-coded feature flags 0..255
|
|
Byte 32 contains information about the validity of the
|
|
previous 32 bytes.
|
|
1 Ok The information in bytes 0..31 is valid
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceLinkEntry 17 }
|
|
|
|
deviceLinkFarFeatureFlagState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ok(1),
|
|
tooEarly(2),
|
|
legacy(3),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates the state and validity of deviceLinkFarFeatureFlag.
|
|
1 Ok The values of farFeatureFlag is valid
|
|
2 TooEarly The variable was read before the LT could determine the farFeatureFlag values
|
|
3 Legacy The far device is an Ulaf-2 device and has no feature flag
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceLinkEntry 18 }
|
|
|
|
-------------------------------
|
|
-- added in V3.0
|
|
-------------------------------
|
|
|
|
deviceLinkSruFeatureFlag OBJECT-TYPE
|
|
SYNTAX OCTET STRING(SIZE(33))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contains a map of features supported by the local device.
|
|
Byte 0-31 contain the bit-coded feature flags 0..255
|
|
Byte 32 contains information about the validity of the
|
|
previous 32 bytes.
|
|
1 Ok The information in bytes 0..31 is valid
|
|
254 unknown values
|
|
255 unsupported variable for addressed device"
|
|
::= { deviceLinkEntry 19 }
|
|
|
|
deviceLinkNumReg3 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
one(2),
|
|
two(3),
|
|
three(4),
|
|
four(5),
|
|
five(6),
|
|
six(7),
|
|
seven(8),
|
|
eight(9),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates how many regenerators were detected in xDSL path 3.
|
|
1 None No regenerator found
|
|
2 One One regenerator found (section A or 1)
|
|
3 Two Two regenerators found (section B or 2)
|
|
4 Three Three regenerators found (section 3)
|
|
5 Four Four regenerators found (section 4)
|
|
6 Five Five regenerators found (section 5)
|
|
7 Six Six regenerators found (section 6)
|
|
8 Seven Seven regenerators found (section 7)
|
|
9 Eight Eight regenerators found (section 8)
|
|
254 unknown value
|
|
255 unsupported value"
|
|
::= { deviceLinkEntry 20 }
|
|
|
|
deviceLinkNumReg4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(1),
|
|
one(2),
|
|
two(3),
|
|
three(4),
|
|
four(5),
|
|
five(6),
|
|
six(7),
|
|
seven(8),
|
|
eight(9),
|
|
unknown(254),
|
|
unsupported(255)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indicates how many regenerators were detected in xDSL path 4.
|
|
1 None No regenerator found
|
|
2 One One regenerator found (section A or 1)
|
|
3 Two Two regenerators found (section B or 2)
|
|
4 Three Three regenerators found (section 3)
|
|
5 Four Four regenerators found (section 4)
|
|
6 Five Five regenerators found (section 5)
|
|
7 Six Six regenerators found (section 6)
|
|
8 Seven Seven regenerators found (section 7)
|
|
9 Eight Eight regenerators found (section 8)
|
|
254 unknown value
|
|
255 unsupported value"
|
|
::= { deviceLinkEntry 21 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
link OBJECT IDENTIFIER ::= { linksVers2 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
linkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LinkConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
::= { link 1 }
|
|
|
|
linkConfigEntry OBJECT-TYPE
|
|
SYNTAX LinkConfigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
""
|
|
INDEX { linkConfigPortIndex, linkConfigIndex }
|
|
::= { linkConfigTable 1 }
|
|
|
|
LinkConfigEntry ::=
|
|
SEQUENCE
|
|
{
|
|
linkConfigPortIndex INTEGER,
|
|
linkConfigIndex INTEGER,
|
|
performance INTEGER
|
|
}
|
|
|
|
linkConfigPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object addresses the port number of the proxy agent"
|
|
::= { linkConfigEntry 1 }
|
|
|
|
linkConfigIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object addresses the line card number of the OMI
|
|
equipment."
|
|
::= { linkConfigEntry 2 }
|
|
|
|
performance OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
on(1),
|
|
off(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object defines if the performance management is running
|
|
or not"
|
|
::= { linkConfigEntry 4}
|
|
|
|
END
|