- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1010 lines
33 KiB
Text
1010 lines
33 KiB
Text
RADLAN-rlInterfaces DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: RADLAN Switch Interfaces Private
|
|
-- Version: 7.40
|
|
-- Date: 30 Nov 2005
|
|
-- 30-Nov-2004 Added type AutoNegCapabilitiesBits
|
|
-- 30-Nov-2004 Added fields swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
|
|
-- swIfOperSpeedDuplexAutoNegotiationLocalCapabilities
|
|
-- swIfSpeedDuplexNegotiationRemoteCapabilities to swIfEntry
|
|
-- 22-Nov-2005 Obsoleted field swIfPhysAddressType
|
|
-- 22-Nov-2005 Added rlIfBaseMACAddressPerIfIndex
|
|
-- 30-Oct-2005 Added swIfExtTable
|
|
-- 30-Nov-2005 Added fields swIfAdminComboMode
|
|
-- swIfOperComboMode swIfExtTable to swIfEntry
|
|
-- 05-Dec-2005 Added rlFlowControlCascadeMode and rlFlowControlCascadeType
|
|
|
|
IMPORTS
|
|
swInterfaces, rlIfInterfaces FROM RADLAN-MIB
|
|
ifIndex FROM IF-MIB
|
|
PortList FROM Q-BRIDGE-MIB
|
|
DisplayString FROM SNMPv2-TC-v1
|
|
Unsigned32, Integer32, Counter32,
|
|
MODULE-IDENTITY, OBJECT-TYPE FROM SNMPv2-SMI
|
|
RowStatus, TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
|
|
|
-- These bits can be set in any combination (except unknown)
|
|
-- for field swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities
|
|
-- and will take affect when field swIfSpeedDuplexAutoNegotiation
|
|
-- will be set to enabled.
|
|
-- In addition these fields can be read for operative values of
|
|
-- auto negotiation capabilities
|
|
AutoNegCapabilitiesBits ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto negotiation capabilities bits."
|
|
SYNTAX BITS {
|
|
default(0),
|
|
unknown(1),
|
|
tenHalf(2),
|
|
tenFull(3),
|
|
fastHalf(4),
|
|
fastFull(5),
|
|
gigaHalf(6),
|
|
gigaFull(7)
|
|
}
|
|
|
|
--
|
|
-- swTable
|
|
--
|
|
|
|
swIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switch media specific information and configuration of the device
|
|
interfaces."
|
|
::= { swInterfaces 1 }
|
|
|
|
swIfEntry OBJECT-TYPE
|
|
SYNTAX SwIfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the contents of each line in the swIfTable table."
|
|
INDEX { swIfIndex }
|
|
::= { swIfTable 1 }
|
|
|
|
SwIfEntry ::= SEQUENCE {
|
|
swIfIndex INTEGER,
|
|
swIfPhysAddressType INTEGER,
|
|
swIfDuplexAdminMode INTEGER,
|
|
swIfDuplexOperMode INTEGER,
|
|
swIfBackPressureMode INTEGER,
|
|
swIfTaggedMode INTEGER,
|
|
swIfTransceiverType INTEGER,
|
|
swIfLockAdminStatus INTEGER,
|
|
swIfLockOperStatus INTEGER,
|
|
swIfType INTEGER,
|
|
swIfDefaultTag INTEGER,
|
|
swIfDefaultPriority INTEGER,
|
|
swIfStatus RowStatus,
|
|
swIfFlowControlMode INTEGER,
|
|
swIfSpeedAdminMode INTEGER,
|
|
swIfSpeedDuplexAutoNegotiation INTEGER,
|
|
swIfOperFlowControlMode INTEGER,
|
|
swIfOperSpeedDuplexAutoNegotiation INTEGER,
|
|
swIfOperBackPressureMode INTEGER,
|
|
swIfAdminLockAction INTEGER,
|
|
swIfOperLockAction INTEGER,
|
|
swIfAdminLockTrapEnable TruthValue,
|
|
swIfOperLockTrapEnable TruthValue,
|
|
swIfOperSuspendedStatus TruthValue,
|
|
swIfLockOperTrapCount INTEGER,
|
|
swIfLockAdminTrapFrequency INTEGER,
|
|
swIfReActivate TruthValue,
|
|
swIfAdminMdix INTEGER,
|
|
swIfOperMdix INTEGER,
|
|
swIfHostMode INTEGER,
|
|
swIfSingleHostViolationAdminAction INTEGER,
|
|
swIfSingleHostViolationOperAction INTEGER,
|
|
swIfSingleHostViolationAdminTrapEnable TruthValue,
|
|
swIfSingleHostViolationOperTrapEnable TruthValue,
|
|
swIfSingleHostViolationOperTrapCount INTEGER,
|
|
swIfSingleHostViolationAdminTrapFrequency INTEGER,
|
|
swIfLockLimitationMode INTEGER,
|
|
swIfLockMaxMacAddresses INTEGER,
|
|
swIfLockMacAddressesCount INTEGER,
|
|
swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
|
|
swIfOperSpeedDuplexAutoNegotiationLocalCapabilities AutoNegCapabilitiesBits,
|
|
swIfSpeedDuplexNegotiationRemoteCapabilities AutoNegCapabilitiesBits,
|
|
swIfAdminComboMode INTEGER,
|
|
swIfOperComboMode INTEGER
|
|
}
|
|
|
|
swIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index to the swIfTable. The interface defined by a
|
|
particular value of this index is the same interface as
|
|
identified by the same value of ifIndex (MIB II)."
|
|
::= { swIfEntry 1 }
|
|
|
|
swIfPhysAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
reserve(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
" This variable indicates whether the physical address assigned to this
|
|
interface should be the default one or be chosen from the set of
|
|
reserved physical addresses of the device."
|
|
DEFVAL { default }
|
|
::= { swIfEntry 2 }
|
|
|
|
swIfDuplexAdminMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
half(2),
|
|
full(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies whether this interface should operate in
|
|
half duplex or full duplex mode. This specification will take effect
|
|
only if swIfSpeedDuplexAutoNegotiation is disabled.
|
|
A value of 'none' is returned if a value of the variable
|
|
hasn't been set."
|
|
DEFVAL { none }
|
|
::= { swIfEntry 3 }
|
|
|
|
swIfDuplexOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
half(1),
|
|
full(2),
|
|
hybrid(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This variable indicates whether this interface operates in half
|
|
duplex or full duplex mode.
|
|
This variable can have the values hybrid or unknown
|
|
only for a trunk.
|
|
unknown - only if trunk operative status is not present."
|
|
::= { swIfEntry 4 }
|
|
|
|
swIfBackPressureMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether this interface activates back pressure
|
|
when congested."
|
|
::= { swIfEntry 5 }
|
|
|
|
swIfTaggedMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enable, this interface operates in tagged mode, i.e all frames sent
|
|
out through this interface will have the 802.1Q header.
|
|
If disabled the frames will not be tagged."
|
|
DEFVAL { disable }
|
|
::= { swIfEntry 6 }
|
|
|
|
swIfTransceiverType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
regular(1),
|
|
fiberOptics(2),
|
|
comboRegular(3),
|
|
comboFiberOptics(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This variable indicates the transceiver type of this interface."
|
|
::= { swIfEntry 7 }
|
|
|
|
swIfLockAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
unlocked(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether this interface should operate in locked
|
|
or unlocked mode.
|
|
In unlocked mode the device learns all MAC addresses from this port and
|
|
forwards all frames arrived at this port. In locked mode no new MAC
|
|
addresses are learned and only frames with known source MAC
|
|
addresses are forwarded."
|
|
DEFVAL { unlocked }
|
|
::= { swIfEntry 8 }
|
|
|
|
swIfLockOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
unlocked(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines whether this interface operates in locked
|
|
or unlocked mode. It is locked in each of the following two cases:
|
|
1) if swLockAdminStatus is set to locked
|
|
2) no IP/IPX interface is defined over this interface and no
|
|
VLAN contains this interface.
|
|
In unlocked mode the device learns all MAC addresses from this port and
|
|
forwards all frames arrived at this port. In locked mode no new MAC
|
|
addresses are learned and only frames with known source MAC
|
|
addresses are forwarded."
|
|
::= { swIfEntry 9 }
|
|
|
|
swIfType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eth10M(1),
|
|
eth100M(2),
|
|
eth1000M(3),
|
|
eth10G(4),
|
|
unknown(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This variable specifies the type of interface."
|
|
::= { swIfEntry 10 }
|
|
|
|
swIfDefaultTag OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the default VLAN tag which will be attached
|
|
to outgoing frames if swIfTaggedMode for this interface is enabled."
|
|
DEFVAL { 0 }
|
|
::= { swIfEntry 11 }
|
|
|
|
swIfDefaultPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This variable specifies the default port priority."
|
|
DEFVAL { 0 }
|
|
::= { swIfEntry 12 }
|
|
|
|
swIfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of a table entry.
|
|
It is used to delete an entry from this table."
|
|
::= { swIfEntry 13 }
|
|
|
|
swIfFlowControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
autoNegotiation(3),
|
|
enabledRx(4),
|
|
enabledTx(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on - Flow control will be enabled on this interface according to the
|
|
IEEE 802.3x standard.
|
|
off - Flow control is disabled.
|
|
autoNegotiation - Flow control will be enabled or disabled on this
|
|
interface. If enabled, it will operate as specified
|
|
by the IEEE 802.3x standard.
|
|
enabledRx - Flow control will be enabled on this interface for
|
|
recieved frames.
|
|
enabledTx - Flow control will be enabled on this interface for
|
|
transmitted frames.
|
|
An attempt to set this object to 'enabledRx(4)' or 'enabledTx(5)'
|
|
will fail on interfaces that do not support operation
|
|
at greater than 100 Mb/s.
|
|
In any case, flow control can work only if swIfDuplexOperMode is
|
|
full."
|
|
::= { swIfEntry 14}
|
|
|
|
swIfSpeedAdminMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the required speed of this interface in bits
|
|
per second. This specification will take effect only if
|
|
swIfSpeedDuplexAutoNegotiation is disabled.
|
|
A value of 10 is returned for 10G.
|
|
A value of 0 is returned if the value of the variable
|
|
hasn't been set."
|
|
DEFVAL { 0 }
|
|
::= { swIfEntry 15 }
|
|
|
|
swIfSpeedDuplexAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled the speed and duplex mode will be set by the device through
|
|
the autonegotiation process. Otherwise these characteristics will be
|
|
set according to the values of swIfSpeedAdminMode and
|
|
swIfSpeedDuplexAutoNegotiation."
|
|
::= { swIfEntry 16 }
|
|
|
|
swIfOperFlowControlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1),
|
|
off(2),
|
|
enabledRx(3),
|
|
enabledTx(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on - Flow control is enabled on this interface according to the
|
|
IEEE 802.3x standard.
|
|
off - Flow control is disabled.
|
|
enabledRx - Flow control is enabled on this interface for
|
|
recieved frames.
|
|
enabledTx - Flow control is enabled on this interface for
|
|
transmitted frames."
|
|
::= { swIfEntry 17}
|
|
|
|
swIfOperSpeedDuplexAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
hybrid(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled the speed and duplex are determined by the device through
|
|
the autonegotiation process.
|
|
If disabled these characteristics are determined according to the values
|
|
of swIfSpeedAdminMode and swIfDuplexAdminMode.
|
|
hybrid - only for a trunk.
|
|
unknown - only for ports that there operative status is not present."
|
|
::= { swIfEntry 18 }
|
|
|
|
swIfOperBackPressureMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2),
|
|
hybrid(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the operative back pressure mode of
|
|
this interface."
|
|
::= { swIfEntry 19 }
|
|
|
|
swIfAdminLockAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discard(1),
|
|
forwardNormal(2),
|
|
discardDisable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates which action this interface should be taken
|
|
in locked mode and therefore relevant only in locked mode.
|
|
Possible actions:
|
|
discard(1) - every packet is dropped.
|
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
|
discardDisable(3) - drops the first packet and suspends the port."
|
|
DEFVAL { discard }
|
|
::= { swIfEntry 20 }
|
|
|
|
|
|
swIfOperLockAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discard(1),
|
|
forwardNormal (2),
|
|
discardDisable(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates which action this interface actually takes in
|
|
locked mode and therefore relevant only in locked mode.
|
|
Possible actions:
|
|
discard(1) - every packet is dropped.
|
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
|
discardDisable(3) - drops the first packet and suspends the port."
|
|
::= { swIfEntry 21 }
|
|
|
|
|
|
swIfAdminLockTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether to create a SNMP trap in the locked mode."
|
|
DEFVAL { false }
|
|
::= { swIfEntry 22 }
|
|
|
|
swIfOperLockTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether a SNMP trap can be created in the
|
|
locked mode."
|
|
::= { swIfEntry 23 }
|
|
|
|
swIfOperSuspendedStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the port is suspended or not due to some
|
|
feature. After reboot this value is false"
|
|
::= { swIfEntry 24 }
|
|
|
|
swIfLockOperTrapCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0 .. 2147483647 )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the trap counter status per ifIndex
|
|
(i.e. number of received packets since the last trap sent due to a
|
|
packet which was received on this ifIndex). It's relevant only in locked
|
|
mode while trap is enabled."
|
|
::= { swIfEntry 25 }
|
|
|
|
swIfLockAdminTrapFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (1 .. 1000000)
|
|
-- UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the minimal frequency (in seconds) of sending
|
|
a trap per ifIndex. It's relevant only in locked mode and in trap
|
|
enabled."
|
|
DEFVAL { 10 }
|
|
::= { swIfEntry 26 }
|
|
|
|
swIfReActivate OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable reactivates (enables) an ifIndex (which was suspended)"
|
|
DEFVAL { false }
|
|
::= { swIfEntry 27 }
|
|
|
|
swIfAdminMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cross(1),
|
|
normal(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configuration is on a physical port, not include trunks.
|
|
cross - The interface should force crossover.
|
|
normal - The interface should not force crossover.
|
|
auto - Auto mdix is enabled on the interface."
|
|
::= { swIfEntry 28 }
|
|
|
|
swIfOperMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
cross(1),
|
|
normal(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cross - The interface is in crossover mode.
|
|
normal - The interface is not in crossover mode.
|
|
unknown - Only for port that its operative status is not present
|
|
or down."
|
|
::= { swIfEntry 29 }
|
|
|
|
swIfHostMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
single(1),
|
|
multiple(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the 802.1X host mode of a port. Relevant when the port's 802.1X control is auto"
|
|
DEFVAL { single }
|
|
::= { swIfEntry 30 }
|
|
|
|
swIfSingleHostViolationAdminAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discard(1),
|
|
forwardNormal (2),
|
|
discardDisable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates which action this interface should take in single authorized.
|
|
Possible actions:
|
|
discard - every packet is dropped.
|
|
forwardNormal - every packet is forwarded according to the DST address.
|
|
discardDisable - drops the first packet and suspends the port."
|
|
DEFVAL { discard }
|
|
::= { swIfEntry 31 }
|
|
|
|
swIfSingleHostViolationOperAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discard(1),
|
|
forwardNormal (2),
|
|
discardDisable(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates which action this interface actually takes in single authorized.
|
|
Possible actions:
|
|
discard(1) - every packet is dropped.
|
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
|
discardDisable(3) - drops the first packet and suspends the port."
|
|
DEFVAL { discard }
|
|
::= { swIfEntry 32 }
|
|
|
|
swIfSingleHostViolationAdminTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether to create a SNMP trap in single authorized."
|
|
DEFVAL { false }
|
|
::= { swIfEntry 33 }
|
|
|
|
swIfSingleHostViolationOperTrapEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether a SNMP trap can be created in the single authorized."
|
|
::= { swIfEntry 34 }
|
|
|
|
swIfSingleHostViolationOperTrapCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0 .. 2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the trap counter status per ifIndex
|
|
(i.e. number of received packets since the last trap sent due to a packet
|
|
which was received on this ifIndex). It's relevant only in single authorized
|
|
while trap is enabled."
|
|
::= { swIfEntry 35 }
|
|
|
|
swIfSingleHostViolationAdminTrapFrequency OBJECT-TYPE
|
|
SYNTAX INTEGER (1 .. 1000000)
|
|
-- UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the minimal frequency (in seconds) of sending a
|
|
trap per ifIndex. It's relevant only in single authorized and in trap enabled."
|
|
DEFVAL { 10 }
|
|
::= { swIfEntry 36 }
|
|
|
|
swIfLockLimitationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(1),
|
|
dynamic(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates what is the learning limitation on the locked interface.
|
|
Possible values:
|
|
disabled - learning is stopped. The dynamic addresses associated with the
|
|
port are not aged out or relearned on other port as long as the port is
|
|
locked.
|
|
dynamic - dynamic addresses can be learned up to the maximum dynamic addresses
|
|
allowed on the port. Relearning and aging of the dynamic addresses are
|
|
enabled. The learned addresses aren't kept after reset."
|
|
DEFVAL { disabled }
|
|
::= { swIfEntry 37 }
|
|
|
|
swIfLockMaxMacAddresses OBJECT-TYPE
|
|
SYNTAX INTEGER (1 .. 2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable defines the maximum number of dynamic addresses that
|
|
can be asscoiated with the locked interface. It isn't relevant in
|
|
disabled limitation mode."
|
|
DEFVAL { 1 }
|
|
::= { swIfEntry 38 }
|
|
|
|
swIfLockMacAddressesCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0 .. 2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the actual number of dynamic addresses that can
|
|
be asscoiated with the locked interface. It isn't relevant in disabled
|
|
limitation mode."
|
|
::= { swIfEntry 39 }
|
|
|
|
swIfAdminSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
|
|
SYNTAX AutoNegCapabilitiesBits
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Administrative auto negotiation capabilities of the interface that can be advertised when
|
|
swIfSpeedDuplexAutoNegotiation is enabled.
|
|
default bit means advertise all the port's capabilities
|
|
according to its type."
|
|
DEFVAL { { default } }
|
|
::= { swIfEntry 40 }
|
|
|
|
swIfOperSpeedDuplexAutoNegotiationLocalCapabilities OBJECT-TYPE
|
|
SYNTAX AutoNegCapabilitiesBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operative auto negotiation capabilities of the remote link.
|
|
unknown bit means that port operative status is not up."
|
|
::= { swIfEntry 41 }
|
|
|
|
swIfSpeedDuplexNegotiationRemoteCapabilities OBJECT-TYPE
|
|
SYNTAX AutoNegCapabilitiesBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Operative auto negotiation capabilities of the remote link.
|
|
unknown bit means that port operative status is not up,
|
|
or auto negotiation process not complete,
|
|
or remote link is not auto negotiation able."
|
|
::= { swIfEntry 42 }
|
|
|
|
swIfAdminComboMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
force-fiber(1),
|
|
force-copper(2),
|
|
prefer-fiber(3),
|
|
prefer-copper(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the administrative mode of a combo Ethernet interface."
|
|
DEFVAL { prefer-fiber }
|
|
::= { swIfEntry 43 }
|
|
|
|
swIfOperComboMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fiber(1),
|
|
copper(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the operative mode of a combo Ethernet interface."
|
|
::= { swIfEntry 44 }
|
|
|
|
swIfMibVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The swIfTable Mib's version, the current version is 3."
|
|
::= { swInterfaces 2 }
|
|
|
|
swIfPortLockSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
supported (1),
|
|
notSupported (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"indicates if the locked port package is supported."
|
|
::= { swInterfaces 3 }
|
|
|
|
|
|
swIfPortLockActionSupport OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"indicates which port lock actions are supported:
|
|
(bit 0 is the most significant bit)
|
|
bit 0 - discard
|
|
bit 1 - forwardNormal
|
|
bit 2 - discardDisable"
|
|
::= { swInterfaces 4 }
|
|
|
|
swIfPortLockTrapSupport OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"indicates with which port lock actions the trap option is supported
|
|
(e.g. discard indicates that trap is supported only when the portlock
|
|
action is discard):
|
|
(bit 0 is the most significant bit)
|
|
bit 0 - discard
|
|
bit 1 - forwardNormal
|
|
bit 2 - discardDisable"
|
|
::= { swInterfaces 5 }
|
|
|
|
swIfPortLockIfRangeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwIfPortLockIfRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port lock interfaces range configuration"
|
|
::= { swInterfaces 6 }
|
|
|
|
swIfPortLockIfRangeEntry OBJECT-TYPE
|
|
SYNTAX SwIfPortLockIfRangeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the contents of each line in the swIfPortLockIfRangeTable table."
|
|
INDEX { swIfPortLockIfRangeIndex }
|
|
::= { swIfPortLockIfRangeTable 1 }
|
|
|
|
SwIfPortLockIfRangeEntry ::= SEQUENCE {
|
|
swIfPortLockIfRangeIndex INTEGER,
|
|
swIfPortLockIfRange PortList,
|
|
swIfPortLockIfRangeLockStatus INTEGER,
|
|
swIfPortLockIfRangeAction INTEGER,
|
|
swIfPortLockIfRangeTrapEn TruthValue,
|
|
swIfPortLockIfRangeTrapFreq INTEGER
|
|
}
|
|
|
|
swIfPortLockIfRangeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index to the swIfPortLockIfRangeTable."
|
|
::= { swIfPortLockIfRangeEntry 1 }
|
|
|
|
swIfPortLockIfRange OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The set of interfaces to which the port lock parameters should be configured"
|
|
::= { swIfPortLockIfRangeEntry 2 }
|
|
|
|
swIfPortLockIfRangeLockStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
unlocked(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the interfaces range should operate in locked
|
|
or unlocked mode.
|
|
In unlocked mode the device learns all MAC addresses from these interfaces and
|
|
forwards all frames arrived at these interfaces. In locked mode no new MAC
|
|
addresses are learned and only frames with known source MAC
|
|
addresses are forwarded."
|
|
DEFVAL { unlocked }
|
|
::= { swIfPortLockIfRangeEntry 3 }
|
|
|
|
swIfPortLockIfRangeAction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
discard(1),
|
|
forwardNormal(2),
|
|
discardDisable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates which action for these interfaces should be take
|
|
in locked mode and therefore relevant only in locked mode.
|
|
Possible actions:
|
|
discard(1) - every packet is dropped.
|
|
forwardNormal(2) - every packet is forwarded according to the DST address.
|
|
discardDisable(3) - drops the first packet and suspends the port."
|
|
DEFVAL { discard }
|
|
::= { swIfPortLockIfRangeEntry 4 }
|
|
|
|
swIfPortLockIfRangeTrapEn OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether to create a SNMP trap in the locked mode."
|
|
DEFVAL { false }
|
|
::= { swIfPortLockIfRangeEntry 5 }
|
|
|
|
swIfPortLockIfRangeTrapFreq OBJECT-TYPE
|
|
SYNTAX INTEGER (1 .. 1000000)
|
|
-- UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the minimal frequency (in seconds) of sending
|
|
a trap for these interfaces. It's relevant only in locked mode and in trap
|
|
enabled."
|
|
DEFVAL { 10 }
|
|
::= { swIfPortLockIfRangeEntry 6 }
|
|
|
|
--
|
|
-- swIfExtTable
|
|
--
|
|
|
|
swIfExtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SwIfExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display information and configuration of the device interfaces."
|
|
::= { swInterfaces 7 }
|
|
|
|
swIfExtEntry OBJECT-TYPE
|
|
SYNTAX SwIfExtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Defines the contents of each row in the swIfExtTable."
|
|
INDEX { ifIndex }
|
|
::= { swIfExtTable 1 }
|
|
|
|
SwIfExtEntry ::= SEQUENCE {
|
|
swIfExtSFPSpeed INTEGER
|
|
}
|
|
|
|
swIfExtSFPSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default(1),
|
|
eth100M(2),
|
|
eth1G(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configure speed of an SFP Ethernet interface."
|
|
DEFVAL { default }
|
|
::= { swIfExtEntry 1 }
|
|
|
|
--
|
|
-- rlIfInterfaces
|
|
--
|
|
|
|
rlIfMibVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MIB's version, the current version is 1."
|
|
::= { rlIfInterfaces 1 }
|
|
|
|
rlIfNumOfPhPorts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of physical ports on this device
|
|
(including all stack units)"
|
|
::= { rlIfInterfaces 2 }
|
|
|
|
rlIfMapOfOnPhPorts OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each bit in this octet string indicates that the correspondig port's
|
|
ifOperStatus is ON if set.
|
|
The mapping of port number to bits in this octet string is as follows:
|
|
The port with the L2 interface number 1 is mapped to the least
|
|
significant bit of the 1st octet, the port with L2 ifNumber 2 to the
|
|
next significant bit in the 1st octet, port 8 to the most-significant
|
|
bit of the in the 1st octet, port 9 to the least
|
|
significant bit of the 2nd octet, etc. and in general,
|
|
port n to bit corresponding to 2**((n mod 8) -1) in byte n/8 + 1"
|
|
::= { rlIfInterfaces 3 }
|
|
|
|
rlIfClearPortMibCounters OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each bit that is set in this portList represent a port that
|
|
its mib counters should be reset."
|
|
::= { rlIfInterfaces 4 }
|
|
|
|
rlIfNumOfUserDefinedPorts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of user defined ports on this device."
|
|
::= { rlIfInterfaces 5 }
|
|
|
|
rlIfFirstOutOfBandIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First ifIndex of out-of-band port.
|
|
This scalar exists only the device has out of band ports."
|
|
::= { rlIfInterfaces 6 }
|
|
|
|
rlIfNumOfLoopbackPorts OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of loopback ports on this device."
|
|
::= { rlIfInterfaces 7 }
|
|
|
|
rlIfFirstLoopbackIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"First ifIndex of loopback port.
|
|
This scalar will exists only if rlIfNumOfLoopbackPorts
|
|
is different from 0."
|
|
::= { rlIfInterfaces 8 }
|
|
|
|
rlIfExistingPortList OBJECT-TYPE
|
|
SYNTAX PortList
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates which ports/trunks exist in the system.
|
|
It doesn't indicate which are present."
|
|
::= { rlIfInterfaces 9 }
|
|
|
|
rlIfBaseMACAddressPerIfIndex OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the system will assign a unique MAC per Ethernet port or not."
|
|
::= { rlIfInterfaces 10 }
|
|
|
|
rlFlowControlCascadeMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"enable disable flow control on cascade ports"
|
|
::= { rlIfInterfaces 11 }
|
|
|
|
rlFlowControlCascadeType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
internalonly(1),
|
|
internalexternal(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"define which type of ports will be affected by flow control on cascade ports"
|
|
::= { rlIfInterfaces 12 }
|
|
|
|
END
|
|
|