- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2360 lines
82 KiB
Text
2360 lines
82 KiB
Text
-- PPC MIB
|
|
-- ====================================================================
|
|
-- Revision History
|
|
-- v0.13 2011-11-10 Gavin Zhao created, Lilinhua modified
|
|
-- *************************NMC v0.0.1.7***********************************
|
|
-- v0.14 2011-11-18 Lilinhua
|
|
-- 1. Modify string "ppcTrap" to "eppcTrap"
|
|
-- 2012-02-09 Lilinhua
|
|
-- 1. Modify upsESystemFaultCode's description "The warning code of UPS" to "The fault code of UPS".
|
|
-- *************************NMC v1.1.0.4************************************
|
|
-- v0.15 2012-07-20 Lilinhua
|
|
-- 1. upsEShutdownWarningPeriodInterval, modify access from read-only to read-write.
|
|
-- 2. upsEShutdownwarningPeriodTime, add unit second.
|
|
-- 2012-07-31 Lilinhua
|
|
-- 1. Modify upsEBatteryTestElapsedTime's format from hh:mm:ss.ss to hh:mm:ss
|
|
-- 2012-08-09 Lilinhua
|
|
-- 1. Modify values of upsEModuleWorkingMode as upsESystemStatus's.
|
|
-- *************************NMC v1.1.0.6************************************
|
|
-- 2012-08-27 Lilinhua
|
|
-- 1. Modify "Moudles" to "Modules", advised by Beth.
|
|
-- 2. Modify module name as phase name "upsEModuleOutputCurrentR", "upsEModuleOutputWattR", "upsEModuleOutputLoadR".
|
|
-- 3. Add Convert module item "upsEModuleTrapState(12)".
|
|
-- 4. Add Convert module item "upsEModuleConfigOutputVA(13)".
|
|
-- 5. Add Convert module item "upsEModuleOutputCurrentS(14)", "upsEModuleOutputCurrentT(15)".
|
|
-- 6. Add Convert module item "upsEModuleOutputWattS(16)", "upsEModuleOutputWattT(17)".
|
|
-- 7. Add Convert module item "upsEModuleOutputLoadS(18)", "upsEModuleOutputLoadT(19)".
|
|
-- 8. Add Convert module item "upsEModuleOutputVAR(20)", "upsEModuleOutputVAS(21)", "upsEModuleOutputVAT(22)".
|
|
-- 9. Modify upsETrapState max length from 255 to 127.
|
|
-- *************************NMC v1.1.0.6************************************
|
|
-- 2012-08-27 Lilinhua
|
|
-- 1. Modify trap description of Overload, OverTemperature.
|
|
-- *************************NMC v1.3.0.0************************************
|
|
-- 2013-06-21 Lilinhua
|
|
-- 1. Add two upsEShutdownEvents: "belowCapacityLimit(11), belowRemainTimeLimit(12)".
|
|
-- 2. Add 4 traps: upsEBelowCapacityLimit, upsENotBelowCapacityLimit, upsEBelowRemainTimeLimit, upsENotBelowRemainTimeLimit.
|
|
-- 3. Add 2 config data: upsESystemConfigBelowCapacityLimit, upsESystemConfigBelowRemainTimeLimit.
|
|
-- 4. Modify upsETrapState's description: "trap 2(battery on)" to "trap 7(battery on)".
|
|
-- *************************NMC v1.4.0.3************************************
|
|
-- 2014-10-15 Lilinhua
|
|
-- 1. Modify descriptions of "upsEEnvironmentTemperatureHighSetPoint, upsEEnvironmentHumidityHighSetPoint,
|
|
-- upsEEnvironmentTemperatureLowSetPoint, upsEEnvironmentHumidityLowSetPoint".
|
|
-- *************************NMC v1.5.0.4************************************
|
|
-- v0.16 2015-01-05 Lilinhua
|
|
-- 1. Modify MIB for add Load segment.
|
|
|
|
|
|
EPPC-MIB DEFINITIONS ::= BEGIN
|
|
IMPORTS
|
|
TRAP-TYPE
|
|
FROM RFC-1215
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
enterprises,Counter, IpAddress
|
|
FROM RFC1155-SMI
|
|
PositiveInteger,NonNegativeInteger
|
|
FROM UPS-MIB;
|
|
|
|
ppc OBJECT IDENTIFIER ::= { enterprises 935 }
|
|
|
|
device OBJECT IDENTIFIER ::= { ppc 10 }
|
|
upsAgent OBJECT IDENTIFIER ::= { device 1 }
|
|
|
|
upsE OBJECT IDENTIFIER ::= { upsAgent 1 }
|
|
upsETraps OBJECT IDENTIFIER ::= { upsAgent 2 }
|
|
upsEIdentity OBJECT IDENTIFIER ::= { upsE 1 }
|
|
upsESystemSummary OBJECT IDENTIFIER ::= { upsE 2 }
|
|
upsEBatterySystem OBJECT IDENTIFIER ::= { upsE 3 }
|
|
upsEPowerConverterSystem OBJECT IDENTIFIER ::= { upsE 4 }
|
|
upsELoadSegment OBJECT IDENTIFIER ::= { upsE 5 }
|
|
upsEEnvironment OBJECT IDENTIFIER ::= { upsE 6 }
|
|
upsEBatteryTest OBJECT IDENTIFIER ::= { upsE 7 }
|
|
upsEControl OBJECT IDENTIFIER ::= { upsE 8 }
|
|
upsETrapControl OBJECT IDENTIFIER ::= { upsE 9 }
|
|
|
|
--========================================================================
|
|
--upsEIdentity
|
|
--========================================================================
|
|
|
|
upsEIdentityManufacturer OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The name of the UPS manufacturer."
|
|
::= { upsEIdentity 1 }
|
|
|
|
upsEIdentityModel OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS Model designation."
|
|
::= { upsEIdentity 2 }
|
|
|
|
upsEIdentityUPSFirmwareVerison OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS firmware/software version(s)."
|
|
::= { upsEIdentity 3 }
|
|
|
|
upsEIndentityUPSSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "optional.
|
|
Most UPS don't supply the value of UPS serial No."
|
|
::= { upsEIdentity 4 }
|
|
|
|
upsEIdentityDescription OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A string to identify the UPS. This object should be
|
|
set by the administrator."
|
|
::= { upsEIdentity 5 }
|
|
|
|
upsEIdentityAgentSoftwareVerison OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The Network Management Card software/firmware version.
|
|
This variable may or may not have the same value as
|
|
upsEIdentGroupUPSSoftwareVersion in some implementations."
|
|
::= { upsEIdentity 6 }
|
|
|
|
upsEIdentityAttachedDevices OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "A string identifying the devices attached to the output(s)
|
|
of the UPS. This object should be set by the administrator"
|
|
::= { upsEIdentity 7 }
|
|
|
|
--========================================================================
|
|
--upsESystemSummary
|
|
--========================================================================
|
|
|
|
upsESystemStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
|
|
line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
|
|
converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The indication of UPS system status."
|
|
::= { upsESystemSummary 1 }
|
|
|
|
upsESystemTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The temperature of UPS presented in 0.1 degree."
|
|
::= { upsESystemSummary 2 }
|
|
|
|
upsESystemWarningCode OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The warning code of UPS. Please refer the warning table
|
|
of 'Q6' for details."
|
|
::= { upsESystemSummary 3 }
|
|
|
|
upsESystemFaultCode OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The fault code of UPS.Please refer the fault code
|
|
of 'Q6' for details."
|
|
::= { upsESystemSummary 4 }
|
|
|
|
upsESystemConfigInputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal input voltage presented in 0.1 V. On those
|
|
systems which support read-write access to this object, if there is an
|
|
attempt to set this variable to a value that is not supported,
|
|
the request must be rejected and the agent shall respond with an
|
|
appropriate error message, i.e., badValue for SNMPv1, or
|
|
inconsistentValue for SNMPv2."
|
|
::= { upsESystemSummary 5 }
|
|
|
|
upsESystemConfigInputFrequence OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal input frequency presented in 0.1 Hz. On those systems which support
|
|
read-write access to this object, if there is an attempt to
|
|
set this variable to a value that is not supported, the request
|
|
must be rejected and the agent shall respond with an appropriate
|
|
error message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
|
|
::= { upsESystemSummary 6 }
|
|
|
|
upsESystemConfigOutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal output voltage presented in 0.1V. On those systems
|
|
which support read-write access to this object, if there is an
|
|
attempt to set this variable to a value that is not supported,
|
|
the request must be rejected and the agent shall respond with an
|
|
appropriate error message, i.e., badValue for SNMPv1, or
|
|
inconsistentValue for SNMPv2"
|
|
::= { upsESystemSummary 7 }
|
|
|
|
upsESystemConfigOutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The nominal output frequency presented in 0.1Hz. On those systems which support
|
|
read-write access to this object, if there is an attempt to set
|
|
this variable to a value that is not supported, the request must
|
|
be rejected and the agent shall respond with an appropriate error
|
|
message, i.e., badValue for SNMPv1, or inconsistentValue for SNMPv2."
|
|
::= { upsESystemSummary 8 }
|
|
|
|
upsESystemConfigOutputVA OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
|
::= { upsESystemSummary 9 }
|
|
|
|
upsESystemConfigOutputPower OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal true power rating presented in W ."
|
|
::= { upsESystemSummary 10 }
|
|
|
|
upsESystemConfigOutputLoadHighSetPoint OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum output load allowed before the load is too high for
|
|
UPS operation "
|
|
::= { upsESystemSummary 11 }
|
|
|
|
upsESystemConfigOverTemperatureSetPoint OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The maximum temperature allowed before the UPS
|
|
operation temperature is too high, presented in 0.1 degree."
|
|
::= { upsESystemSummary 12 }
|
|
|
|
upsESystemInputSourceNum OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The present external source of input power."
|
|
::= { upsESystemSummary 13 }
|
|
|
|
upsESystemInputLineBads OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of times the Input was out of tolerance in voltage or frequency.
|
|
Its value should be initialized 0 after agent restarting. "
|
|
::= { upsESystemSummary 14 }
|
|
|
|
upsESystemInputNumPhases OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of input phase utilized is this device, serves as the table index.
|
|
This value indicate the device initialized feature."
|
|
::= { upsESystemSummary 15 }
|
|
|
|
upsESystemInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsSystemInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of input table entries. The number of entries is given by the
|
|
value of upsESystemInputNumPhase."
|
|
::= { upsESystemSummary 16 }
|
|
|
|
upsESystemInputEntry OBJECT-TYPE
|
|
SYNTAX UpsSystemInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular input line."
|
|
INDEX { upsESystemInputPhase }
|
|
::= { upsESystemInputTable 1 }
|
|
|
|
UpsSystemInputEntry ::= SEQUENCE {
|
|
upsESystemInputPhase PositiveInteger,
|
|
upsESystemInputFrequency NonNegativeInteger,
|
|
upsESystemInputVoltage NonNegativeInteger,
|
|
upsESystemInputCurrent NonNegativeInteger,
|
|
upsESystemInputWatts NonNegativeInteger
|
|
}
|
|
|
|
|
|
upsESystemInputPhase OBJECT-TYPE
|
|
SYNTAX PositiveInteger( 1 .. 3 )
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the phase. Serves as index for input table"
|
|
::= { upsESystemInputEntry 1 }
|
|
|
|
|
|
upsESystemInputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input frquency from the UPS meters in 0.1Hz."
|
|
::= { upsESystemInputEntry 2 }
|
|
|
|
|
|
upsESystemInputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input voltage from the UPS meters in 0.1 volts"
|
|
::= { upsESystemInputEntry 3 }
|
|
|
|
|
|
upsESystemInputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input mandatory from the UPS meters in 0.1 amps."
|
|
::= { upsESystemInputEntry 4 }
|
|
|
|
|
|
upsESystemInputWatts OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input real power in watts."
|
|
::= { upsESystemInputEntry 5 }
|
|
|
|
upsESystemOutputNumPhase OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of metered output phases, serves as the table index.
|
|
This value indicate the device initialized feature."
|
|
::= { upsESystemSummary 17 }
|
|
|
|
upsESystemOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsSystemOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of output table entries. The number of entries is given
|
|
by the value of upsESystemOutputNumPhase."
|
|
::= { upsESystemSummary 18 }
|
|
|
|
upsESystemOutputEntry OBJECT-TYPE
|
|
SYNTAX UpsSystemOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
|
INDEX { upsESystemOutputPhase }
|
|
::= { upsESystemOutputTable 1 }
|
|
|
|
UpsSystemOutputEntry ::= SEQUENCE {
|
|
upsESystemOutputPhase PositiveInteger,
|
|
upsESystemOutputFrequency NonNegativeInteger,
|
|
upsESystemOutputVoltage NonNegativeInteger,
|
|
upsESystemOutputCurrent NonNegativeInteger,
|
|
upsESystemOutputWatts NonNegativeInteger,
|
|
upsESystemOutputVA NonNegativeInteger,
|
|
upsESystemOutputLoad NonNegativeInteger
|
|
}
|
|
|
|
|
|
upsESystemOutputPhase OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the phase. Serves as index for output table"
|
|
::= { upsESystemOutputEntry 1 }
|
|
|
|
|
|
upsESystemOutputFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output frequency from the UPS meters in 0.1Hz."
|
|
::= { upsESystemOutputEntry 2 }
|
|
|
|
|
|
upsESystemOutputVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output voltage from the UPS meters in 0.1 volts"
|
|
::= { upsESystemOutputEntry 3 }
|
|
|
|
|
|
upsESystemOutputCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output mandatory from the UPS meters in 0.1 amps."
|
|
::= { upsESystemOutputEntry 4 }
|
|
|
|
|
|
upsESystemOutputWatts OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output real power in watts."
|
|
::= { upsESystemOutputEntry 5 }
|
|
|
|
upsESystemOutputVA OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured output real complex power in VA."
|
|
::= { upsESystemOutputEntry 6 }
|
|
|
|
|
|
upsESystemOutputLoad OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS output load in percent of rated capacity."
|
|
::= { upsESystemOutputEntry 7 }
|
|
|
|
upsESystemBypassNumPhase OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of bypass phases, serves as the table index.
|
|
This value indicate the device initialized feature"
|
|
::= { upsESystemSummary 19 }
|
|
|
|
upsESystemBypassTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsSystemBypassEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of bypass table entries. The number of entries is given by the
|
|
value of upsESystemBypassNumPhase."
|
|
::= { upsESystemSummary 20 }
|
|
|
|
|
|
upsESystemBypassEntry OBJECT-TYPE
|
|
SYNTAX UpsSystemBypassEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
|
INDEX { upsESystemBypassPhase }
|
|
::= { upsESystemBypassTable 1 }
|
|
|
|
UpsSystemBypassEntry ::= SEQUENCE {
|
|
upsESystemBypassPhase PositiveInteger,
|
|
upsESystemBypassFrequency NonNegativeInteger,
|
|
upsESystemBypassVoltage NonNegativeInteger,
|
|
upsESystemBypassCurrent NonNegativeInteger,
|
|
upsESystemBypassWatts NonNegativeInteger
|
|
}
|
|
|
|
|
|
upsESystemBypassPhase OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 3 )
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of the phase. Serves as index for bypass table"
|
|
::= { upsESystemBypassEntry 1 }
|
|
|
|
|
|
upsESystemBypassFrequency OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured bypass frequency from the UPS meters in 0.1 Hz."
|
|
::= { upsESystemBypassEntry 2 }
|
|
|
|
|
|
upsESystemBypassVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured bypass voltage from the UPS meters in 0.1 volts"
|
|
::= { upsESystemBypassEntry 3 }
|
|
|
|
|
|
upsESystemBypassCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured bypass mandatory from the UPS meters in 0.1 amps"
|
|
::= { upsESystemBypassEntry 4 }
|
|
|
|
|
|
upsESystemBypassWatts OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured input real power in watts."
|
|
::= { upsESystemBypassEntry 5 }
|
|
|
|
|
|
upsESystemConfigBelowCapacityLimit OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS batteries capacity(%) limit for shutdown"
|
|
::= { upsESystemSummary 21 }
|
|
|
|
upsESystemConfigBelowRemainTimeLimit OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS batteries backup time(minute) limit for shutdown"
|
|
::= { upsESystemSummary 22 }
|
|
|
|
--========================================================================
|
|
--upsEBatterySystem
|
|
--========================================================================
|
|
|
|
upsEBatteryStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { unknown ( 1 ) , batteryNormal ( 2 ) , batteryLow ( 3 ) ,
|
|
batteryDepleted ( 4 ) , batteryDischarging ( 5 ) , batteryFailure ( 6 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION " The status of UPS battery, a value of batteryLow indicates
|
|
that the battery-low status bit has been set from device.
|
|
A value of batteryDepleted indicates that the UPS will be
|
|
unable to sustain the present load when and if the utility
|
|
power is lost (including the possibility that the utility
|
|
power is mandatoryly absent and the UPS is unable to sustain
|
|
the output)"
|
|
::= { upsEBatterySystem 1 }
|
|
|
|
upsESecondsOnBattery OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "If the unit is on battery power, the elapsed time
|
|
since the UPS last switched to battery power, or the
|
|
time since the network management subsystem was last
|
|
restarted, whichever is less. 0 shall be returned
|
|
if the unit is not on battery power"
|
|
::= { upsEBatterySystem 2 }
|
|
|
|
upsEBatteryEstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off."
|
|
::= { upsEBatterySystem 3 }
|
|
|
|
upsEBatteryEstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32 ( 0 .. 100 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "An estimate of the battery charge remaining expressed
|
|
as a percent of full charge"
|
|
::= { upsEBatterySystem 4 }
|
|
|
|
upsEPositiveBatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the present positive battery voltage in 0.1 Volt DC"
|
|
::= { upsEBatterySystem 5 }
|
|
|
|
upsENegativeBatteryVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the present negative battery voltage in 0.1 Volt DC"
|
|
::= { upsEBatterySystem 6 }
|
|
|
|
upsEBatteryCellNumber OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This object indicate the cell number of each set."
|
|
::= { upsEBatterySystem 7 }
|
|
|
|
upsEBatteryTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The ambient temperature at or near the UPS Battery
|
|
casing in 0.1 degree."
|
|
::= { upsEBatterySystem 8 }
|
|
|
|
upsEBatteryLastReplacedDate OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The date when the Batteries in this UPS were last replaced.
|
|
The format should be DD/MM/YYYY."
|
|
::= { upsEBatterySystem 9 }
|
|
|
|
upsEBatteryABMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { charge ( 1 ) , float ( 2 ) , rest ( 3 ) ,
|
|
discharge ( 4 ) , disable ( 5 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION " The status of ABM."
|
|
::= { upsEBatterySystem 10 }
|
|
|
|
upsEChargerModulesNum OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger ( 0 .. 32 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of charger modules inserted to UPS systems. served
|
|
as the index of the upsEChargerModulesTable.
|
|
The default value 0 indicate that the UPS system don't have
|
|
separate charger module."
|
|
::= { upsEBatterySystem 11 }
|
|
|
|
upsEChargerModulesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsChargerModulesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of charger modules entries. The number of entries is given
|
|
by the value of upsEchargerModulesNum."
|
|
::= { upsEBatterySystem 12 }
|
|
|
|
upsEChargerModulesEntry OBJECT-TYPE
|
|
SYNTAX UpsChargerModulesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular charger module."
|
|
INDEX { chargerModulesNum }
|
|
::= { upsEChargerModulesTable 1 }
|
|
|
|
UpsChargerModulesEntry ::= SEQUENCE {
|
|
chargerModulesNum PositiveInteger,
|
|
chargerModulesAddress NonNegativeInteger ,
|
|
positiveChargeVotlage NonNegativeInteger,
|
|
negativeChargeVoltage NonNegativeInteger,
|
|
positiveChargeCurrent NonNegativeInteger,
|
|
negativeChargeCurrent NonNegativeInteger,
|
|
chargerModulesTemperature INTEGER,
|
|
chargerModulesMode INTEGER
|
|
}
|
|
|
|
|
|
chargerModulesNum OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 32 )
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of charger modules. Serves as index for charger module table"
|
|
::= { upsEChargerModulesEntry 1 }
|
|
|
|
|
|
chargerModulesAddress OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Charger Modules' address."
|
|
::= { upsEChargerModulesEntry 2 }
|
|
|
|
|
|
positiveChargeVotlage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured positive charger voltage from the UPS meters in 0.1 volts"
|
|
::= { upsEChargerModulesEntry 3 }
|
|
|
|
|
|
negativeChargeVoltage OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured nepositive charger voltage from the UPS meters in 0.1 volts"
|
|
::= { upsEChargerModulesEntry 4 }
|
|
|
|
|
|
positiveChargeCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured positive charger mandatory from the UPS meters in in 0.1 amps."
|
|
::= { upsEChargerModulesEntry 5 }
|
|
|
|
|
|
negativeChargeCurrent OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured nepositive charger mandatory from the UPS meters in 0.1 amps."
|
|
::= { upsEChargerModulesEntry 6 }
|
|
|
|
|
|
chargerModulesTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured charger temperature from the UPS meters in 0.1 degree."
|
|
::= { upsEChargerModulesEntry 7 }
|
|
|
|
|
|
chargerModulesMode OBJECT-TYPE
|
|
SYNTAX INTEGER { powerOn ( 1 ) , standyby ( 2 ) , fault ( 3 ) , shutdown ( 4 ) ,
|
|
running ( 5 ) , suicide ( 6 ) , unknown ( 7 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The working mode of charger modules."
|
|
::= { upsEChargerModulesEntry 8 }
|
|
|
|
--========================================================================
|
|
--upsEPowerConverterSystem
|
|
--========================================================================
|
|
|
|
upsEUPSModulesNum OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger ( 0 .. 32 )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of UPS modules inserted to UPS systems.
|
|
served as the index of the upsEModulesTable.
|
|
the default value 0 indicate that the UPS system do not
|
|
have separate UPS module."
|
|
::= { upsEPowerConverterSystem 1 }
|
|
|
|
upsEModulesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsModulesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of UPS modules entries. The number of entries is
|
|
given by the value of upsEModulesNum."
|
|
::= { upsEPowerConverterSystem 2 }
|
|
|
|
upsEModulesEntry OBJECT-TYPE
|
|
SYNTAX UpsModulesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular upsE module."
|
|
INDEX { upsEModulesNum }
|
|
::= { upsEModulesTable 1 }
|
|
|
|
UpsModulesEntry ::= SEQUENCE {
|
|
upsEModulesNum PositiveInteger,
|
|
upsEModuleAddress INTEGER,
|
|
upsEModulePositiveBusVolt NonNegativeInteger,
|
|
upsEModuleNegativeBusVolt NonNegativeInteger,
|
|
upsEModuleTemperature INTEGER,
|
|
upsEModuleWorkingMode INTEGER,
|
|
upsEModuleOutputCurrentR NonNegativeInteger,
|
|
upsEModuleOutputWattR NonNegativeInteger,
|
|
upsEModuleOutputLoadR INTEGER,
|
|
upsEModuleWarningCode DisplayString,
|
|
upsEModuleFaultCode DisplayString,
|
|
|
|
upsEModuleTrapState DisplayString,
|
|
upsEModuleConfigOutputVA NonNegativeInteger,
|
|
upsEModuleOutputCurrentS NonNegativeInteger,
|
|
upsEModuleOutputCurrentT NonNegativeInteger,
|
|
upsEModuleOutputWattS NonNegativeInteger,
|
|
upsEModuleOutputWattT NonNegativeInteger,
|
|
upsEModuleOutputLoadS INTEGER,
|
|
upsEModuleOutputLoadT INTEGER,
|
|
upsEModuleOutputVAR NonNegativeInteger,
|
|
upsEModuleOutputVAS NonNegativeInteger,
|
|
upsEModuleOutputVAT NonNegativeInteger
|
|
}
|
|
|
|
|
|
upsEModulesNum OBJECT-TYPE
|
|
SYNTAX PositiveInteger ( 1 .. 32 )
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of UPS modules. Serves as index for UPS module table"
|
|
::= { upsEModulesEntry 1 }
|
|
|
|
|
|
upsEModuleAddress OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "the address of UPS modules."
|
|
::= { upsEModulesEntry 2 }
|
|
|
|
|
|
upsEModulePositiveBusVolt OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured positive upsE module voltage from the UPS meters in 0.1 volts"
|
|
::= { upsEModulesEntry 3 }
|
|
|
|
|
|
upsEModuleNegativeBusVolt OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured nepositive upsE module voltage from the UPS meters in 0.1 volts"
|
|
::= { upsEModulesEntry 4 }
|
|
|
|
|
|
upsEModuleTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module temperature from the UPS meters in 0.1 degree."
|
|
::= { upsEModulesEntry 5 }
|
|
|
|
|
|
upsEModuleWorkingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {power-on ( 1 ) , stand-by( 2 ) , by-pass ( 3 ) ,
|
|
line( 4 ) , battery ( 5 ) , battery-test ( 6 ) , fault ( 7 ) ,
|
|
converter ( 8 ) , eco ( 9 ) , shutdown ( 10 ) , on-booster ( 11 ) , on-reducer ( 12 ) , other( 13 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The working mode of UPS modules."
|
|
::= { upsEModulesEntry 6 }
|
|
|
|
|
|
upsEModuleOutputCurrentR OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
|
::= { upsEModulesEntry 7 }
|
|
|
|
|
|
upsEModuleOutputWattR OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
|
::= { upsEModulesEntry 8 }
|
|
|
|
|
|
upsEModuleOutputLoadR OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The output load of UPS modules in %."
|
|
::= { upsEModulesEntry 9 }
|
|
|
|
upsEModuleWarningCode OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The warning code of ups modules.Please refer the warning table of 'QU,XX' for details."
|
|
::= { upsEModulesEntry 10 }
|
|
|
|
upsEModuleFaultCode OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 15 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The fault code of ups modules.Please refer command 'QU,XX' for details."
|
|
::= { upsEModulesEntry 11 }
|
|
|
|
upsEModuleTrapState OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "the values indicate the unrestored traps.
|
|
For example, after AC fail, so the value of upsETrapState should be '1'.
|
|
And then the AC restore, the value of upsEModuleTrapState
|
|
should change to empty."
|
|
::= { upsEModulesEntry 12 }
|
|
|
|
|
|
upsEModuleConfigOutputVA OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
|
::= { upsEModulesEntry 13 }
|
|
|
|
|
|
upsEModuleOutputCurrentS OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
|
::= { upsEModulesEntry 14 }
|
|
|
|
upsEModuleOutputCurrentT OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output mandatory from the UPS meters in 0.1 A."
|
|
::= { upsEModulesEntry 15 }
|
|
|
|
upsEModuleOutputWattS OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
|
::= { upsEModulesEntry 16 }
|
|
|
|
upsEModuleOutputWattT OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measured upsE module output watts from the UPS meters in watts."
|
|
::= { upsEModulesEntry 17 }
|
|
|
|
upsEModuleOutputLoadS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The output load of UPS modules in %."
|
|
::= { upsEModulesEntry 18 }
|
|
|
|
upsEModuleOutputLoadT OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The output load of UPS modules in %."
|
|
::= { upsEModulesEntry 19 }
|
|
|
|
upsEModuleOutputVAR OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
|
::= { upsEModulesEntry 20 }
|
|
|
|
upsEModuleOutputVAS OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
|
::= { upsEModulesEntry 21 }
|
|
|
|
upsEModuleOutputVAT OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The magnitude of the nominal Volt-Amp rating presented in VA."
|
|
::= { upsEModulesEntry 22 }
|
|
|
|
--========================================================================
|
|
--upsELoadSegment
|
|
--========================================================================
|
|
upsELoadSegment1OffDelay OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
|
|
Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
|
|
abort the countdown. Read this object will get countdown value of the Load Segment."
|
|
::= { upsELoadSegment 1 }
|
|
|
|
upsELoadSegment1OnDelay OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
|
|
including starting the UPS, if necessary. Setting this object to 0 will cause the startup
|
|
to occur immediately. Setting this object to -1 will abort the countdown."
|
|
::= { upsELoadSegment 2 }
|
|
|
|
upsELoadSegment1AutoOffTimer OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
|
|
but the shutdown is cancelled if the utility return before the delay has expired."
|
|
::= { upsELoadSegment 3 }
|
|
|
|
upsELoadSegment1AutoOnTimer OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The load segment is automatically turned on after a selected delay
|
|
if it has been shutdown due to on battery."
|
|
::= { upsELoadSegment 4 }
|
|
|
|
upsELoadSegment1State OBJECT-TYPE
|
|
SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Load segment output state."
|
|
::= { upsELoadSegment 5 }
|
|
|
|
upsELoadSegment2OffDelay OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this object will shutdown the UPS Load Segment output after the indicated number of seconds, or less.
|
|
Setting this object to 0 will cause the shutdown to occur immediately. Setting this object to -1 will
|
|
abort the countdown. Read this object will get countdown value of the Load Segment."
|
|
::= { upsELoadSegment 6 }
|
|
|
|
upsELoadSegment2OnDelay OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this object will start the Load segment output after the indicated number of seconds,
|
|
including starting the UPS, if necessary. Setting this object to 0 will cause the startup
|
|
to occur immediately. Setting this object to -1 will abort the countdown."
|
|
::= { upsELoadSegment 7 }
|
|
|
|
upsELoadSegment2AutoOffTimer OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The load segment turns automatically off after the delay while the unit operates on battery,
|
|
but the shutdown is cancelled if the utility return before the delay has expired."
|
|
::= { upsELoadSegment 8 }
|
|
|
|
upsELoadSegment2AutoOnTimer OBJECT-TYPE
|
|
-- Valid value is from -1 to 32767
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The load segment is automatically turned on after a selected delay
|
|
if it has been shutdown due to on battery."
|
|
::= { upsELoadSegment 9 }
|
|
|
|
upsELoadSegment2State OBJECT-TYPE
|
|
SYNTAX INTEGER { off(1), on(2), off-pending(3), on-pending(4), not-support(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "Load segment output state."
|
|
::= { upsELoadSegment 10 }
|
|
|
|
--========================================================================
|
|
--upsEEnvironment
|
|
--========================================================================
|
|
|
|
upsEEnvironmentTemperature OBJECT IDENTIFIER ::= { upsEEnvironment 1 }
|
|
|
|
upsEEnvironmentCurrentTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measurement of temperature sensor, in 0.1 degree"
|
|
::= { upsEEnvironmentTemperature 1 }
|
|
|
|
upsEEnvironmentTemperatureHighSetPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The set point for high temperature warning, in 0.1 degrees.
|
|
This value must be greater than upsEEnvironmentTemperatureLowSetPoint,
|
|
and the least significant digit must be zero."
|
|
::= { upsEEnvironmentTemperature 2 }
|
|
|
|
upsEEnvironmentTemperatureHighStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "To enable/disable high set point check with sensor temperature."
|
|
::= { upsEEnvironmentTemperature 3 }
|
|
|
|
upsEEnvironmentTemperatureLowSetPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The set point for low temperature warning, in 0.1 degrees.
|
|
This value must be less than upsEEnvironmentTemperatureHighSetPoint,
|
|
and the least significant digit must be zero."
|
|
::= { upsEEnvironmentTemperature 4 }
|
|
|
|
upsEEnvironmentTemperatureLowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "To enable/disable low set point check with sensor temperature."
|
|
::= { upsEEnvironmentTemperature 5 }
|
|
|
|
upsEEnvironmentTemperatureOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The offset to calibrate temperature of EMD, in 0.1 degrees"
|
|
::= { upsEEnvironmentTemperature 6 }
|
|
|
|
upsEEnvironmentHumidity OBJECT IDENTIFIER ::= { upsEEnvironment 2 }
|
|
|
|
upsEEnvironmentCurrentHumidity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The measurement of sensor humidity present in %."
|
|
::= { upsEEnvironmentHumidity 1 }
|
|
|
|
upsEEnvironmentHumidityHighSetPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The set point for high humidity warning, in %.
|
|
This value must be greater than upsEEnvironmentHumidityLowSetPoint."
|
|
::= { upsEEnvironmentHumidity 2 }
|
|
|
|
upsEEnvironmentHumidityHighStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "To enable/disable high set point check with emd humidity."
|
|
::= { upsEEnvironmentHumidity 3 }
|
|
|
|
upsEEnvironmentHumidityLowSetPoint OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The set point for low humidity warning, in %.
|
|
This value must be less than upsEEnvironmentHumidityHighSetPoint."
|
|
::= { upsEEnvironmentHumidity 4 }
|
|
|
|
upsEEnvironmentHumidityLowStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { enable ( 1 ) , disable ( 2 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "To enable/disable high set point check with emd humidity."
|
|
::= { upsEEnvironmentHumidity 5 }
|
|
|
|
upsEEnvironmentHumidityOffset OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The offset to calibrate humidity of EMD, in %."
|
|
::= { upsEEnvironmentHumidity 6 }
|
|
|
|
upsEEnvironmentContactsNum OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of environment contacts, serves as the table index."
|
|
::= { upsEEnvironment 3 }
|
|
|
|
upsEEnvironmentContactTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsEEnvironmentContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "A list of contacts table entries. The number of entries is given by the
|
|
value of upsEEnvironmentContactsNum"
|
|
::= { upsEEnvironment 4 }
|
|
|
|
upsEEnvironmentContactEntry OBJECT-TYPE
|
|
SYNTAX UpsEEnvironmentContactEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular contact"
|
|
INDEX { upsEEnvironmentContactIndex }
|
|
::= { upsEEnvironmentContactTable 1 }
|
|
|
|
UpsEEnvironmentContactEntry ::= SEQUENCE {
|
|
upsEEnvironmentContactIndex PositiveInteger,
|
|
upsEEnvironmentContactType INTEGER,
|
|
upsEEnvironmentContactState INTEGER,
|
|
upsEEnvironmentContactDescription DisplayString
|
|
}
|
|
|
|
|
|
upsEEnvironmentContactIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The number of environment contacts. Serves as index for environment contact table"
|
|
::= { upsEEnvironmentContactEntry 1 }
|
|
|
|
|
|
upsEEnvironmentContactType OBJECT-TYPE
|
|
SYNTAX INTEGER { normallyOpen ( 1 ) , normallyClosed ( 2 ) , notUsed ( 3 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "operation type"
|
|
::= { upsEEnvironmentContactEntry 2 }
|
|
|
|
|
|
upsEEnvironmentContactState OBJECT-TYPE
|
|
SYNTAX INTEGER { open ( 1 ) , closed ( 2 ) , openWithNotice ( 3 ) , closedWithNotice ( 4 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The mandatory status."
|
|
::= { upsEEnvironmentContactEntry 3 }
|
|
|
|
|
|
upsEEnvironmentContactDescription OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 31 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Description of environment contact."
|
|
::= { upsEEnvironmentContactEntry 4 }
|
|
|
|
--========================================================================
|
|
--upsEBatteryTest
|
|
--========================================================================
|
|
|
|
upsEBatteryTestStart OBJECT-TYPE
|
|
SYNTAX INTEGER { none ( 1 ) , batteryTest10Sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
|
|
batteryTestWithTime ( 4 ) , cancelBatteryTest ( 5 ) , clearBatteryInfo ( 6 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "This object specify the battery test type and initiate battery test.
|
|
If battTestWithTime selected, the test time is refer to upsEBatteryTestSettingTime."
|
|
::= { upsEBatteryTest 1 }
|
|
|
|
upsEBatteryTestSettingTime OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The object specify the test time for battery test in seconds."
|
|
::= { upsEBatteryTest 2 }
|
|
|
|
upsEBatteryTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER { idle ( 1 ) , processing ( 2 ) , noFailure ( 3 ) ,
|
|
failureOrWarning ( 4 ) , notPossible ( 5 ) , testCancel ( 6 ) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "This object indicate the test result of battery."
|
|
::= { upsEBatteryTest 3 }
|
|
|
|
upsEBatteryTestStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 19 .. 19 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The value of the time the test in progress was initiated,
|
|
or, if no test is in progress, the time the previous test
|
|
was initiated. If the value of upsETestBatteryTestResult
|
|
is noTestsInitiated(6), upsETestStartTime has the value
|
|
01/01/1970 00:00:00."
|
|
::= { upsEBatteryTest 4 }
|
|
|
|
upsEBatteryTestElapsedTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 11 .. 11 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The amount of time in format hh:mm:ss, since the test in progress
|
|
was initiated, or, if no test is in progress, the previous
|
|
test took to complete. If the value of upsTestResultsSummary
|
|
is idle(1), upsTestElapsedTime has the value 00:00:00."
|
|
::= { upsEBatteryTest 5 }
|
|
|
|
|
|
upsEBatteryTestScheduleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsBatteryTestScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "This table describes the schedule for automatically battery
|
|
test."
|
|
::= { upsEBatteryTest 6 }
|
|
|
|
upsEBatteryTestScheduleEntry OBJECT-TYPE
|
|
SYNTAX UpsBatteryTestScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to schedule test."
|
|
INDEX { upsEBatteryTestScheduleIndex }
|
|
::= { upsEBatteryTestScheduleTable 1 }
|
|
|
|
UpsBatteryTestScheduleEntry ::= SEQUENCE {
|
|
upsEBatteryTestScheduleIndex PositiveInteger,
|
|
upsEBatteryTestScheduleDay INTEGER,
|
|
upsEBatteryTestScheduleTime DisplayString,
|
|
upsEBatteryTestScheduleType INTEGER,
|
|
upsEBatteryTestScheduleTestWithTime NonNegativeInteger,
|
|
upsEBatteryTestScheduleSpecialDay DisplayString
|
|
}
|
|
|
|
|
|
upsEBatteryTestScheduleIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The index of battery test scheduled."
|
|
::= { upsEBatteryTestScheduleEntry 1 }
|
|
|
|
|
|
upsEBatteryTestScheduleDay OBJECT-TYPE
|
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednsday ( 3 ) ,
|
|
thusday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
|
sunday ( 7 ) , specialday ( 8 ) , none ( 9 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The weekday or specaial day on which the UPS should start battery test."
|
|
::= { upsEBatteryTestScheduleEntry 2 }
|
|
|
|
|
|
upsEBatteryTestScheduleTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 5 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The time that the battery test will be initiated in hh:mm format."
|
|
::= { upsEBatteryTestScheduleEntry 3 }
|
|
|
|
|
|
upsEBatteryTestScheduleType OBJECT-TYPE
|
|
SYNTAX INTEGER { none ( 1 ) , batteryTest10sec ( 2 ) , batteryTestUntilLow ( 3 ) ,
|
|
batteryTestWithTime ( 4 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The type of battery test."
|
|
::= { upsEBatteryTestScheduleEntry 5 }
|
|
|
|
|
|
upsEBatteryTestScheduleTestWithTime OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The battery time of setting time test in seconds."
|
|
::= { upsEBatteryTestScheduleEntry 6 }
|
|
|
|
|
|
upsEBatteryTestScheduleSpecialDay OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 10 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The special day that the battery test will be initiated in dd/mm/yyyy format."
|
|
::= { upsEBatteryTestScheduleEntry 7 }
|
|
|
|
--========================================================================
|
|
-- upsEControl
|
|
--========================================================================
|
|
|
|
upsEControlOutputOffDelay OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value to other than zero will cause the UPS
|
|
output to turn off after the number of seconds. "
|
|
::= { upsEControl 1 }
|
|
|
|
upsEControlOutputOnDelay OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Setting this value to other than zero will cause the
|
|
UPS output to turn on after the number of seconds. "
|
|
::= { upsEControl 2 }
|
|
|
|
upsEControlOutputOnOffControl OBJECT-TYPE
|
|
SYNTAX INTEGER { upsEOutputOff ( 1 ) , upsEOutputOffCancel ( 2 ) , upsESleep( 3 ) , none ( 4 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "upsEOutputOff ( 1 ) indicates the shutdown sequence,
|
|
upsEOutputOffCancel ( 2 ) indicates cancel the shutdown sequence,
|
|
upsESleep( 3 ) indicates shutdown UPS first, then switch on."
|
|
::= { upsEControl 3 }
|
|
|
|
upsEShutdownEventsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsShutdownEventsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "This table describes the parametes for shutdown process
|
|
when shutdown event occurs"
|
|
::= { upsEControl 4 }
|
|
|
|
upsEShutdownEventsEntry OBJECT-TYPE
|
|
SYNTAX UpsShutdownEventsEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular shutdown
|
|
event line"
|
|
INDEX { upsEShutdownEvent }
|
|
::= { upsEShutdownEventsTable 1 }
|
|
|
|
UpsShutdownEventsEntry ::= SEQUENCE {
|
|
upsEShutdownEvent INTEGER,
|
|
upsEShutdownEventAction INTEGER,
|
|
upsEShutdownwarningPeriodTime NonNegativeInteger,
|
|
upsEShutdownWarningPeriodInterval NonNegativeInteger
|
|
}
|
|
|
|
|
|
upsEShutdownEvent OBJECT-TYPE
|
|
SYNTAX INTEGER { acFail ( 1 ) , batteryLow ( 2 ) , upsEOverLoad ( 3 ) ,
|
|
upsEOverTemperature ( 4 ) , upsEWeeklySchedule ( 5 ) ,
|
|
upsESpecialSchedule ( 6 ) , environmentTemperatureOverThreshold ( 7 ) ,
|
|
environmentHumidityOverThreshold ( 8 ) , environmentContact1Alarm ( 9 ) ,
|
|
environmentContact2Alarm ( 10 ), belowCapacityLimit( 11 ), belowRemainTimeLimit( 12 )}
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The shutdown event identification"
|
|
::= { upsEShutdownEventsEntry 1 }
|
|
|
|
|
|
upsEShutdownEventAction OBJECT-TYPE
|
|
SYNTAX INTEGER { disable ( 1 ) , warning ( 2 ) , shutdownClient ( 3 ) , shutdownUPS ( 4 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Status of the corresponding shutdown Event.
|
|
When set to disable(), shutdown process will not start when
|
|
corresponding event occured."
|
|
::= { upsEShutdownEventsEntry 2 }
|
|
|
|
|
|
upsEShutdownwarningPeriodTime OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The Delay in seconds after the occurance of the curresponding shutdown
|
|
event, and warning message should be popped in this period."
|
|
::= { upsEShutdownEventsEntry 3 }
|
|
|
|
|
|
upsEShutdownWarningPeriodInterval OBJECT-TYPE
|
|
SYNTAX NonNegativeInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The frequency of sending warning messages to the connected
|
|
clients when the curresponding shutdown event occurs.
|
|
The value is in units of seconds."
|
|
::= { upsEShutdownEventsEntry 4 }
|
|
|
|
upsEControlWeeklyScheduleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsControlWeeklyScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The table to schedule shutting down the ups by weekly"
|
|
::= { upsEControl 5 }
|
|
|
|
upsEControlWeeklyScheduleEntry OBJECT-TYPE
|
|
SYNTAX UpsControlWeeklyScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular line"
|
|
INDEX { upsEControlWeeklyScheduleIndex }
|
|
::= { upsEControlWeeklyScheduleTable 1 }
|
|
|
|
UpsControlWeeklyScheduleEntry ::= SEQUENCE {
|
|
upsEControlWeeklyScheduleIndex PositiveInteger,
|
|
upsEWeeklyScheduleShutdownDay INTEGER,
|
|
upsEWeeklyScheduleShutdownTime DisplayString,
|
|
upsEWeeklyScheduleRestartDay INTEGER,
|
|
upsEWeeklyScheduleRestartTime DisplayString
|
|
}
|
|
|
|
|
|
upsEControlWeeklyScheduleIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "the index of schedule events."
|
|
::= { upsEControlWeeklyScheduleEntry 1 }
|
|
|
|
|
|
upsEWeeklyScheduleShutdownDay OBJECT-TYPE
|
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
|
|
thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
|
sunday ( 7 ) , none ( 8 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "the weekday on which upsE shoud shutdown"
|
|
::= { upsEControlWeeklyScheduleEntry 2 }
|
|
|
|
|
|
upsEWeeklyScheduleShutdownTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 5 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The time that the process of shutting down the UPS will be initiated
|
|
in hh:mm format."
|
|
::= { upsEControlWeeklyScheduleEntry 3 }
|
|
|
|
|
|
upsEWeeklyScheduleRestartDay OBJECT-TYPE
|
|
SYNTAX INTEGER { monday ( 1 ) , tuesday ( 2 ) , wednesday ( 3 ) ,
|
|
thursday ( 4 ) , friday ( 5 ) , saturday ( 6 ) ,
|
|
sunday ( 7 ) , none ( 8 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "the weekday on which the UPS should restart."
|
|
::= { upsEControlWeeklyScheduleEntry 4 }
|
|
|
|
|
|
upsEWeeklyScheduleRestartTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The time the UPS will restart in hh:mm format."
|
|
::= { upsEControlWeeklyScheduleEntry 5 }
|
|
|
|
upsEControlSpecialDayScheduleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsControlSpecialDayScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The table to schedule shutting down the ups."
|
|
::= { upsEControl 6 }
|
|
|
|
upsEControlSpecialDayScheduleEntry OBJECT-TYPE
|
|
SYNTAX UpsControlSpecialDayScheduleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular line."
|
|
INDEX { upsEControlSpecialDayScheduleIndex }
|
|
::= { upsEControlSpecialDayScheduleTable 1 }
|
|
|
|
UpsControlSpecialDayScheduleEntry ::= SEQUENCE {
|
|
upsEControlSpecialDayScheduleIndex PositiveInteger,
|
|
upsESpecialDayScheduleShutdownDay DisplayString,
|
|
upsESpecialDayScheduleShutdownTime DisplayString,
|
|
upsESpecialDayScheduleRestartDay DisplayString,
|
|
upsESpecialDayScheduleRestartTime DisplayString
|
|
}
|
|
|
|
|
|
upsEControlSpecialDayScheduleIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The index of special day schedule."
|
|
::= { upsEControlSpecialDayScheduleEntry 1 }
|
|
|
|
|
|
upsESpecialDayScheduleShutdownDay OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The special day on which UPS should shutdown with the format
|
|
of DD/MM/YYYY."
|
|
::= { upsEControlSpecialDayScheduleEntry 2 }
|
|
|
|
|
|
upsESpecialDayScheduleShutdownTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The time that the process of shutting down the UPS will be initiated
|
|
in hh:mm format."
|
|
::= { upsEControlSpecialDayScheduleEntry 3 }
|
|
|
|
|
|
upsESpecialDayScheduleRestartDay OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 10 .. 10 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The special day on which the UPS should restart with the format
|
|
of DD/MM/YYYY."
|
|
::= { upsEControlSpecialDayScheduleEntry 4 }
|
|
|
|
|
|
upsESpecialDayScheduleRestartTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 5 .. 5 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The time the UPS will restart in hh:mm format."
|
|
::= { upsEControlSpecialDayScheduleEntry 5 }
|
|
|
|
upsESystemMasterOffDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS output will shutdown after the indicated number of seconds, -1 indicate no action."
|
|
::= { upsEControl 7 }
|
|
upsESystemMasterOnDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "The UPS output will start on after the indicated number of seconds, -1 indicate no action."
|
|
::= { upsEControl 8 }
|
|
|
|
--========================================================================
|
|
-- upsETrapControl
|
|
--========================================================================
|
|
|
|
upsETrapsReceiversTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UpsTrapsReceiversEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION " This table list the managers'IP to send traps to."
|
|
::= { upsETrapControl 1 }
|
|
|
|
upsETrapsReceiversEntry OBJECT-TYPE
|
|
SYNTAX UpsTrapsReceiversEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "An entry containing information applicable to a particular input line."
|
|
INDEX { upsETrapsReceiversIndex }
|
|
::= { upsETrapsReceiversTable 1 }
|
|
|
|
UpsTrapsReceiversEntry ::= SEQUENCE {
|
|
upsETrapsReceiversIndex PositiveInteger,
|
|
upsETrapsReceiverAddress DisplayString,
|
|
upsETrapReceiverCommunityString DisplayString,
|
|
upsETrapType INTEGER,
|
|
upsETrapsSeverityLevel INTEGER,
|
|
upsETrapReceiverDescription DisplayString
|
|
}
|
|
|
|
upsETrapsReceiversIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION "The index to a trap receiver entry"
|
|
::= { upsETrapsReceiversEntry 1 }
|
|
|
|
upsETrapsReceiverAddress OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 45 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The IP address of the manager to send a trap to."
|
|
::= { upsETrapsReceiversEntry 2 }
|
|
|
|
upsETrapReceiverCommunityString OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 32 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The community name to use in the trap when
|
|
sent to the manager."
|
|
::= { upsETrapsReceiversEntry 3 }
|
|
|
|
upsETrapType OBJECT-TYPE
|
|
SYNTAX INTEGER { none ( 1 ) , rfc1628Trap ( 2 ) , eppcTrap ( 3 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The type of trap to be received by the manager."
|
|
::= { upsETrapsReceiversEntry 4 }
|
|
|
|
upsETrapsSeverityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER { informational ( 1 ) , warning ( 2 ) , severe ( 3 ) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "The severity level of traps to be received by this manager."
|
|
::= { upsETrapsReceiversEntry 5 }
|
|
|
|
upsETrapReceiverDescription OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 63 ) )
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION "Description of trap receivers"
|
|
::= { upsETrapsReceiversEntry 6 }
|
|
|
|
upsETrapState OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE ( 0 .. 127 ) )
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION "the values indicate the unrestored traps.
|
|
For example, after AC fail, the agent send
|
|
the trap 1(AC Fail) and trap 7(battery on) to
|
|
NMS. so the value of upsETrapState should be '1,7'.
|
|
And then the AC restore, the value of upsETrapState
|
|
should change to empty."
|
|
::= { upsETrapControl 2 }
|
|
|
|
-- ===========================================================================
|
|
-- Trap defination
|
|
-- ===========================================================================
|
|
|
|
upsEPowerFail TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Utility power not available."
|
|
::= 1
|
|
|
|
upsEPowerRestored TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Utility power has restored."
|
|
::= 2
|
|
|
|
upsELowBattery TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"SEVERE: The UPS batteries are low and will soon be exhausted."
|
|
::= 3
|
|
|
|
upsEReturnFromLowBattery TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS has return from a low battery condition."
|
|
::= 4
|
|
|
|
upsEFailed TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"SEVERE: The UPS is not working fine."
|
|
::= 5
|
|
|
|
upsEOk TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is working fine."
|
|
::= 6
|
|
|
|
upsEOnBattery TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEBatteryEstimatedMinutesRemaining,
|
|
upsESecondsOnBattery
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: The UPS has switched to battery backup power."
|
|
::= 7
|
|
|
|
upsENotOnBattery TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is not on battery power."
|
|
::= 8
|
|
|
|
upsETestInProgress TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The testing is going on ups."
|
|
::= 9
|
|
|
|
upsETestOver TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEBatteryTestStart,
|
|
upsEBatteryTestSettingTime,
|
|
upsEBatteryTestResult,
|
|
upsEBatteryTestStartTime
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: The testing of UPS is completed."
|
|
::= 10
|
|
|
|
upsEBypassOn TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS has enabled bypass."
|
|
::= 11
|
|
|
|
upsEOnline TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is not on Bypass and return to normal status."
|
|
::= 12
|
|
|
|
upsECommunicationLost TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"SEVERE: Communication to the UPS has been lost."
|
|
::= 13
|
|
|
|
upsECommunicationEstablished TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Communication with the UPS has been established."
|
|
::= 14
|
|
|
|
upsEGoingShutdown TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: The UPS is going to shutdown output."
|
|
::= 15
|
|
|
|
upsEShutdownCancelled TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is not going to shutdown output."
|
|
::= 16
|
|
|
|
upsEOutlet1GoingShutdown TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: The UPS is going to shutdown outlet1."
|
|
::= 17
|
|
|
|
upsEOutlet1ShutdownCancelled TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is not going to shutdown outlet1."
|
|
::= 18
|
|
|
|
upsEOutlet2GoingShutdown TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: The UPS is going to shutdown outlet2."
|
|
::= 19
|
|
|
|
upsEOutlet2ShutdownCancelled TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS is not going to shutdown outlet2."
|
|
::= 20
|
|
|
|
upsESleeping TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEControlOutputOnDelay
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: UPS has entered sleep mode and power to load has been cut off."
|
|
::= 21
|
|
|
|
upsEWokeUp TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS woke up from sleep mode and power to load has been restored."
|
|
::= 22
|
|
|
|
upsEOverTemperature TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsESystemTemperature,
|
|
upsESystemConfigOverTemperatureSetPoint
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: The UPS temperature is over the setting limit."
|
|
::= 23
|
|
|
|
upsENotOverTemperature TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsESystemTemperature,
|
|
upsESystemConfigOverTemperatureSetPoint
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS temperature is not over the setting limit."
|
|
::= 24
|
|
|
|
upsEOverLoad TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsESystemOutputLoad,
|
|
upsESystemConfigOutputLoadHighSetPoint
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: The UPS load is over the setting limit."
|
|
::= 25
|
|
|
|
upsENotOverLoad TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsESystemOutputLoad,
|
|
upsESystemConfigOutputLoadHighSetPoint
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS load is not over the setting limit."
|
|
::= 26
|
|
|
|
upsEModuleInserted TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: UPS module or charger module plug-in."
|
|
::= 27
|
|
|
|
upsEModuleRemoved TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: UPS module or charger module unplugs."
|
|
::= 28
|
|
|
|
sensorTemperatureTooHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentTemperatureHighSetPoint,
|
|
upsEEnvironmentCurrentTemperature
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Sensor Temperature over high Set point."
|
|
::= 29
|
|
|
|
sensorTemperatureNotHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentTemperatureHighSetPoint,
|
|
upsEEnvironmentCurrentTemperature
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Sensor Temperature not over high Set point."
|
|
::= 30
|
|
|
|
sensorTemperatureTooLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentTemperatureLowSetPoint,
|
|
upsEEnvironmentCurrentTemperature
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Sensor Temperature under low Set point."
|
|
::= 31
|
|
|
|
sensorTemperatureNotLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentTemperatureLowSetPoint,
|
|
upsEEnvironmentCurrentTemperature
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Sensor Temperature not under low Set point."
|
|
::= 32
|
|
|
|
sensorHumidityTooHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentHumidityHighSetPoint,
|
|
upsEEnvironmentCurrentHumidity
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Sensor Humidity over high Set point."
|
|
::= 33
|
|
|
|
sensorHumidityNotHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentHumidityHighSetPoint,
|
|
upsEEnvironmentCurrentHumidity
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Sensor Humidity not over high Set point."
|
|
::= 34
|
|
|
|
sensorHumidityTooLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentHumidityLowSetPoint,
|
|
upsEEnvironmentCurrentHumidity
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Sensor Humidity under low Set point."
|
|
::= 35
|
|
|
|
sensorHumidityNotLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentHumidityLowSetPoint,
|
|
upsEEnvironmentCurrentHumidity
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Sensor Humidity not under low Set point."
|
|
::= 36
|
|
|
|
contactAlarm1Active TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentContactType,
|
|
upsEEnvironmentContactDescription
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Contact Alarm-1 activated."
|
|
::= 37
|
|
|
|
concactAlarm1Normal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentContactType,
|
|
upsEEnvironmentContactDescription
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Contact Alarm-1 not active."
|
|
::= 38
|
|
|
|
contactAlarm2Active TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentContactType,
|
|
upsEEnvironmentContactDescription
|
|
}
|
|
DESCRIPTION
|
|
"WARNING: Contact Alarm-2 activated."
|
|
::= 39
|
|
|
|
contactAlarm2Normal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEEnvironmentContactType,
|
|
upsEEnvironmentContactDescription
|
|
}
|
|
DESCRIPTION
|
|
"INFORMATION: Contact Alarm-2 not active."
|
|
::= 40
|
|
|
|
upsEInternalwarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Internal warning."
|
|
::= 41
|
|
|
|
upsEReturnFromInternalwarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Internal warning."
|
|
::= 42
|
|
|
|
upsEEPOActive TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: EPO Active."
|
|
::= 43
|
|
|
|
upsEReturnFromEPOActive TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from EPO Active."
|
|
::= 44
|
|
|
|
upsEModuleUnlock TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Module Unlock."
|
|
::= 45
|
|
|
|
upsEReturnFromModuleUnlock TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Module Unlock."
|
|
::= 46
|
|
|
|
upsEMain1Neutralloss TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Main 1 Neutral loss."
|
|
::= 47
|
|
|
|
upsEReturnFromMain1Neutralloss TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Main 1 Neutral loss."
|
|
::= 48
|
|
|
|
upsEMain1phaseerror TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Main 1 phase error."
|
|
::= 49
|
|
|
|
upsEReturnFromMain1phaseerror TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Main 1 phase error."
|
|
::= 50
|
|
|
|
upsESitefault TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Site fault."
|
|
::= 51
|
|
|
|
upsEReturnFromSitefault TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Site fault."
|
|
::= 52
|
|
|
|
upsEBypassAbnormal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Bypass Abnormal."
|
|
::= 53
|
|
|
|
upsEReturnFromBypassAbnormal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Bypass Abnormal."
|
|
::= 54
|
|
|
|
upsEBypassPhaseError TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Bypass Phase Error."
|
|
::= 55
|
|
|
|
upsEReturnFromBypassPhaseError TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Bypass Phase Error."
|
|
::= 56
|
|
|
|
upsEBatteryOpen TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Battery Open."
|
|
::= 57
|
|
|
|
upsEReturnFromBatteryOpen TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Battery Open."
|
|
::= 58
|
|
|
|
upsEBatteryOverCharge TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Battery Over Charge."
|
|
::= 59
|
|
|
|
upsEReturnFromBatteryOverCharge TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Battery Over Charge."
|
|
::= 60
|
|
|
|
upsEBatteryReverse TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Battery Reverse."
|
|
::= 61
|
|
|
|
upsEReturnFromBatteryReverse TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Battery Reverse."
|
|
::= 62
|
|
|
|
upsEOverloadforewarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Overload forewarning."
|
|
::= 63
|
|
|
|
upsEReturnFromOverloadforewarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Overload forewarning."
|
|
::= 64
|
|
|
|
upsEOverloadWarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Overload Warning."
|
|
::= 65
|
|
|
|
upsEReturnFromOverloadWarning TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Overload Warning."
|
|
::= 66
|
|
|
|
upsEFanLock TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Fan Lock."
|
|
::= 67
|
|
|
|
upsEReturnFromFanLock TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Fan Lock."
|
|
::= 68
|
|
|
|
upsEMaintaincoverisopen TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Maintain cover is open."
|
|
::= 69
|
|
|
|
upsEReturnFromMaintaincoverisopen TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Maintain cover is open."
|
|
::= 70
|
|
|
|
upsEChargerfault TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Charger fault."
|
|
::= 71
|
|
|
|
upsEReturnFromChargerfault TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Charger fault."
|
|
::= 72
|
|
|
|
upsEModulelocationerror TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Module location error."
|
|
::= 73
|
|
|
|
upsEReturnFromModulelocationerror TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Module location error."
|
|
::= 74
|
|
|
|
upsETurnonabnormal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Turn on abnormal."
|
|
::= 75
|
|
|
|
upsEReturnFromTurnonabnormal TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Turn on abnormal."
|
|
::= 76
|
|
|
|
upsERedundancyloss TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Redundancy loss."
|
|
::= 77
|
|
|
|
upsEReturnFromRedundancyloss TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Redundancy loss."
|
|
::= 78
|
|
|
|
upsEHotSwapActived TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Hot Swap Active."
|
|
::= 79
|
|
|
|
upsEReturnFromHotSwapActived TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Hot Swap Active."
|
|
::= 80
|
|
|
|
upsEBatteryInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Battery Inform."
|
|
::= 81
|
|
|
|
upsEReturnFromBatteryInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Battery Inform."
|
|
::= 82
|
|
|
|
upsEInspectionInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Inspection Inform."
|
|
::= 83
|
|
|
|
upsEReturnFromInspectionInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Inspection Inform."
|
|
::= 84
|
|
|
|
upsEGuaranteeInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Guarantee Inform."
|
|
::= 85
|
|
|
|
upsEReturnFromGuaranteeInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Guarantee Inform."
|
|
::= 86
|
|
|
|
upsETemperatureLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Temperature Low."
|
|
::= 87
|
|
|
|
upsEReturnFromTemperatureLow TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Temperature Low."
|
|
::= 88
|
|
|
|
upsETemperatureHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Temperature High."
|
|
::= 89
|
|
|
|
upsEReturnFromTemperatureHigh TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Temperature High."
|
|
::= 90
|
|
|
|
upsEBatteryOverTemperature TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Battery Over Temperature."
|
|
::= 91
|
|
|
|
upsEReturnFromBatteryOverTemperature TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Battery Over Temperature."
|
|
::= 92
|
|
|
|
upsEFanMaintainInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Fan Maintain Inform."
|
|
::= 93
|
|
|
|
upsEReturnFromFanMaintainInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Fan Maintain Inform."
|
|
::= 94
|
|
|
|
upsEBusCapacitanceMaintainInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Bus Capacitance Maintain Inform."
|
|
::= 95
|
|
|
|
upsEReturnFromBusCapacitanceMaintainInform TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from Bus Capacitance Maintain Inform."
|
|
::= 96
|
|
|
|
upsESystemOverCapacity TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: System Over Capacity."
|
|
::= 97
|
|
|
|
upsEReturnFromSystemOverCapacity TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Return from System Over Capacity."
|
|
::= 98
|
|
|
|
-- Trap Id 99-122 is not defined.
|
|
|
|
upsEBelowCapacityLimit TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEBatteryEstimatedChargeRemaining,
|
|
upsESystemConfigBelowCapacityLimit
|
|
}
|
|
DESCRIPTION
|
|
"SEVERE: The UPS batteries capacity is lower than setting limit."
|
|
::= 123
|
|
|
|
upsENotBelowCapacityLimit TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS batteries capacity is not lower than setting limit."
|
|
::= 124
|
|
|
|
upsEBelowRemainTimeLimit TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
VARIABLES {
|
|
upsEBatteryEstimatedMinutesRemaining,
|
|
upsESystemConfigBelowRemainTimeLimit
|
|
}
|
|
DESCRIPTION
|
|
"SEVERE: The UPS batteries backup time is below the setting limit."
|
|
::= 125
|
|
|
|
upsENotBelowRemainTimeLimit TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: The UPS batteries backup time is not below the setting limit."
|
|
::= 126
|
|
|
|
upsELoadSegment1Off TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Load segment 1 is off."
|
|
::= 127
|
|
upsELoadSegment1On TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Load segment 1 is on."
|
|
::= 128
|
|
|
|
upsELoadSegment2Off TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"WARNING: Load segment 2 is off."
|
|
::= 129
|
|
upsELoadSegment2On TRAP-TYPE
|
|
ENTERPRISE upsETraps
|
|
DESCRIPTION
|
|
"INFORMATION: Load segment 2 is on."
|
|
::= 130
|
|
|
|
END
|
|
|