- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
86 lines
2.5 KiB
Text
86 lines
2.5 KiB
Text
-- ********************************************************************
|
|
LAN DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
enterprises, IpAddress,Unsigned32, Counter64, OBJECT-TYPE, MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
DisplayString, RowStatus, TruthValue, MacAddress
|
|
FROM SNMPv2-TC;
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
-- The Enterprises Number
|
|
peplink OBJECT IDENTIFIER ::= { enterprises 23695 }
|
|
|
|
productMib OBJECT IDENTIFIER ::= { peplink 200 }
|
|
|
|
generalMib OBJECT IDENTIFIER ::= { productMib 1 }
|
|
|
|
lanMib OBJECT IDENTIFIER ::= { generalMib 3 }
|
|
|
|
-- ********************************************************************
|
|
-- * MODULE IDENTITY
|
|
-- ********************************************************************
|
|
lanInfo MODULE-IDENTITY
|
|
LAST-UPDATED "201305220000Z" -- 05 22, 2013 at 12:00 GMT
|
|
ORGANIZATION
|
|
"PEPLINK"
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"MIB module for LAN."
|
|
::= { lanMib 1 }
|
|
|
|
-- Local type define ----------------------------------------------------------
|
|
PortSpeedType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Describe the port speed and type."
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
auto(1),
|
|
fullDulplex10(2),
|
|
halfDulplex10(3),
|
|
fullDulplex100(4),
|
|
halfDulplex100(5),
|
|
fullDulplex1000(6),
|
|
halfDulplex1000(7)
|
|
}
|
|
|
|
|
|
-- #####################################################################
|
|
--
|
|
-- **********************************************************************
|
|
-- * MIB attribute OBJECT-TYPE definitions follow
|
|
-- **********************************************************************
|
|
lanStatus OBJECT IDENTIFIER ::= { lanInfo 1 }
|
|
|
|
lanIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN IP address."
|
|
::= { lanStatus 1 }
|
|
|
|
lanSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LAN subnet mask."
|
|
::= { lanStatus 2 }
|
|
|
|
lanSpeed OBJECT-TYPE
|
|
SYNTAX PortSpeedType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "LAN speed status (Auto/10baseT-FD/
|
|
10baseT-HD/100baseTx-FD/100baseTx-HD/1000baseTx-FD/
|
|
1000baseTx-HD."
|
|
::= { lanStatus 3 }
|
|
END
|