- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2591 lines
88 KiB
Text
2591 lines
88 KiB
Text
-- *****************************************************************
|
||
-- SFP MIB
|
||
-- *****************************************************************
|
||
|
||
SL-SFP-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
MODULE-IDENTITY, OBJECT-TYPE,
|
||
NOTIFICATION-TYPE, Integer32, TimeTicks
|
||
FROM SNMPv2-SMI
|
||
Float32TC, Float64TC, Float128TC FROM FLOAT-TC-MIB
|
||
DisplayString, TruthValue,
|
||
TimeStamp FROM SNMPv2-TC
|
||
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
||
MODULE-COMPLIANCE, OBJECT-GROUP,
|
||
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
||
InterfaceIndex FROM IF-MIB
|
||
PerfCurrentCount, PerfIntervalCount,
|
||
PerfTotalCount FROM PerfHist-TC-MIB
|
||
CleiCode FROM SL-ENTITY-MIB
|
||
sitelight FROM SL-NE-MIB;
|
||
|
||
slSfp MODULE-IDENTITY
|
||
LAST-UPDATED "200501250000Z"
|
||
ORGANIZATION "PacketLight Networks Ltd."
|
||
CONTACT-INFO
|
||
"Omri_Viner@PacketLight.com"
|
||
DESCRIPTION
|
||
"This MIB module describes the SFP Modules"
|
||
::= { sitelight 10 }
|
||
|
||
-- The SFP MIB consists of the following groups:
|
||
-- SFP Configuration Table
|
||
-- SFP Diagnostic Table
|
||
-- SFP Traps
|
||
|
||
sfpConf OBJECT IDENTIFIER ::= { slSfp 1 }
|
||
sfpDiag OBJECT IDENTIFIER ::= { slSfp 2 }
|
||
sfpTraps OBJECT IDENTIFIER ::= { slSfp 3 }
|
||
sfpTune OBJECT IDENTIFIER ::= { slSfp 4 }
|
||
|
||
-- Textual Conventions
|
||
|
||
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Configuration Table
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpConfigTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SfpConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SFP configuration table.
|
||
The table defines the configuration of the SFP-1310 and
|
||
the SFP-WDM modules."
|
||
::= { sfpConf 1 }
|
||
|
||
sfpConfigEntry OBJECT-TYPE
|
||
SYNTAX SfpConfigEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the SFP configuration table.
|
||
The index to this table is the same as the ifIndex of the SFP.
|
||
The SFP Config Table contain and entry for each
|
||
module of a type SFP."
|
||
INDEX { sfpConfigInterface }
|
||
::= { sfpConfigTable 1 }
|
||
|
||
SfpConfigEntry ::=
|
||
SEQUENCE {
|
||
sfpConfigInterface InterfaceIndex,
|
||
|
||
-- Base ID Fields
|
||
sfpConfigXcvrId INTEGER,
|
||
sfpConfig1310ExtXcvrId INTEGER, -- 1310
|
||
sfpConfigWdmExtXcvrId INTEGER, -- 15xy
|
||
sfpConfigConnectorCode INTEGER,
|
||
sfpConfigInfibandCompliance INTEGER,
|
||
sfpConfigEsconCompliance INTEGER,
|
||
sfpConfigSonetCompliance INTEGER,
|
||
sfpConfigGbeCompliance INTEGER,
|
||
sfpConfigFcCompliance INTEGER,
|
||
sfpConfigEncodingCode INTEGER,
|
||
sfpConfigNominalBitRate INTEGER,
|
||
sfpConfigLength9mKm INTEGER,
|
||
sfpConfigLength9m100m INTEGER, -- 1310
|
||
sfpConfigLength50m10m INTEGER, -- 1310
|
||
sfpConfigLength62m10m INTEGER, -- 1310
|
||
sfpConfigLengthCopper1m INTEGER, -- 1310
|
||
sfpConfigMaxTemp INTEGER, -- 15xy
|
||
sfpConfigMinTemp INTEGER, -- 15xy
|
||
sfpConfigMaxSupplyCurrent INTEGER, -- 15xy
|
||
sfpConfigChannelSpacing INTEGER, -- 15xy
|
||
sfpConfigVendorName SnmpAdminString,
|
||
sfpConfigOptionalWdm INTEGER, -- 15xy
|
||
sfpConfigVendorOUI INTEGER,
|
||
sfpConfigVendorPN SnmpAdminString,
|
||
sfpConfigVendorRev SnmpAdminString,
|
||
sfpConfigWaveLength INTEGER, -- 15xy only
|
||
|
||
-- Extended ID Fields
|
||
sfpConfigExtendedOptions INTEGER,
|
||
sfpConfigMaxBitRate INTEGER,
|
||
sfpConfigMinBitRate INTEGER,
|
||
sfpConfigVendorSN SnmpAdminString,
|
||
sfpConfigDateCode SnmpAdminString,
|
||
sfpConfigDiagnosticMonitoring INTEGER,
|
||
sfpConfigEnhanceOptions INTEGER,
|
||
sfpConfig8472Compliance INTEGER,
|
||
|
||
sfpConfigTunableWaveLength INTEGER, -- 15xy
|
||
sfpConfigVoaControl INTEGER, -- 15xy
|
||
sfpConfigVdtControl INTEGER, -- 15xy
|
||
sfpConfigPilotToneModulation INTEGER, -- 15xy
|
||
|
||
-- Non standard Fields
|
||
sfpConfigCleiCode DisplayString,
|
||
|
||
-- XFP standard Fields
|
||
sfpConfigXfpExtXcvrId INTEGER,
|
||
sfpConfigXfpEncodingCode INTEGER,
|
||
sfpConfigXfpMinBitRate INTEGER,
|
||
sfpConfigXfpMaxBitRate INTEGER,
|
||
sfpConfig10GSonetCompliance INTEGER,
|
||
sfpConfig10GbeCompliance INTEGER,
|
||
sfpConfig10GFcCompliance INTEGER,
|
||
sfpConfigXfpDeviceTech INTEGER,
|
||
|
||
-- XFP SFP-8477 Extended Fields (Tuning and Dither)
|
||
sfpConfigXfpTuningSupported INTEGER,
|
||
sfpConfigXfpDesiredWl INTEGER,
|
||
sfpConfigXfpWlError INTEGER,
|
||
sfpConfigXfpDesiredChannel INTEGER,
|
||
sfpConfigXfpDesiredFreq INTEGER,
|
||
sfpConfigXfpFreqError INTEGER,
|
||
sfpConfigXfpDitherSupported TruthValue,
|
||
sfpConfigXfpDitherAdmin INTEGER,
|
||
sfpConfigXfpCapFreqFirstThz INTEGER,
|
||
sfpConfigXfpCapFreqFirst10Ghz INTEGER,
|
||
sfpConfigXfpCapFreqLastThz INTEGER,
|
||
sfpConfigXfpCapFreqLast10Ghz INTEGER,
|
||
sfpConfigXfpCapMaxSpacing10Ghz INTEGER,
|
||
sfpConfigXfpCalibrationSupported TruthValue,
|
||
sfpConfigXfpCalibrationEnabled TruthValue,
|
||
|
||
-- CFP MSA Rev 1.4
|
||
sfpConfigCfpExtId INTEGER,
|
||
sfpConfigCfpConnectorType INTEGER,
|
||
sfpConfigCfpEthernetCode INTEGER,
|
||
sfpConfigCfpFcCode INTEGER,
|
||
sfpConfigCfpCopperCode INTEGER,
|
||
sfpConfigCfpSonetCode INTEGER,
|
||
sfpConfigCfpOtnCode INTEGER,
|
||
sfpConfigCfpSupportedRates INTEGER,
|
||
sfpConfigCfpSupportedLanes INTEGER,
|
||
sfpConfigCfpMediaProperties INTEGER,
|
||
sfpConfigCfpMaxNetworkLaneRate INTEGER,
|
||
sfpConfigCfpMaxHostLaneRate INTEGER,
|
||
sfpConfigCfpMaxSmFiberLength INTEGER,
|
||
sfpConfigCfpMaxMmFiberLength INTEGER,
|
||
sfpConfigCfpMaxCopperCableLength INTEGER,
|
||
sfpConfigCfpMinWavelenPerActive INTEGER,
|
||
sfpConfigCfpMaxWavelenPerActive INTEGER,
|
||
sfpConfigCfpMaxLenOpticalWidth INTEGER,
|
||
sfpConfigCfpSpacing INTEGER,
|
||
|
||
-- QSFP+ SFF-8436
|
||
sfpConfigQsfppEthernetCode INTEGER,
|
||
sfpConfigQsfppSonetCode INTEGER,
|
||
|
||
-- CXP
|
||
sfpConfigCxpExtId INTEGER,
|
||
sfpConfigCxpConnectorType INTEGER,
|
||
sfpConfigCxpMaxSupportedRate INTEGER,
|
||
sfpConfigCxpNominalWavelength INTEGER,
|
||
sfpConfigCxpDeviceTech INTEGER,
|
||
|
||
-- Coherent
|
||
sfpConfigCohRxDesiredChannel INTEGER,
|
||
sfpConfigCohRxDesiredWl INTEGER,
|
||
sfpConfigCohRxDesiredFreq INTEGER,
|
||
sfpConfigCohCurrentCD INTEGER,
|
||
sfpConfigCohCurrentOSNR INTEGER,
|
||
sfpConfigCohAverageOSNR INTEGER,
|
||
sfpConfigCohMaxCD INTEGER,
|
||
|
||
-- DSP
|
||
sfpConfigNyquist TruthValue
|
||
}
|
||
|
||
sfpConfigInterface OBJECT-TYPE
|
||
SYNTAX InterfaceIndex
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Interface Index of the SFP (type=196)."
|
||
::= { sfpConfigEntry 1 }
|
||
|
||
-- Base ID Fields
|
||
|
||
sfpConfigXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
unknone(0), -- Unknown or unspecified
|
||
gbic(1), -- GBIC
|
||
module(2), -- Module/connector soldered to motherboard
|
||
sfp1310(3), -- 1310 SFP
|
||
xfp(6), -- XFP
|
||
sfpDwdm(11), -- DWDM SFP
|
||
qsfp(12), -- QSFP
|
||
qsfpPlus(13), -- QSFP+
|
||
cfp(14), -- CFP
|
||
cxp(15), -- CXP
|
||
coherent(16), -- Coherent
|
||
qsfp28(17), -- QSFP28
|
||
cfp2(20) -- CFP2
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The identifier value specifies the physical device described by the serial information.
|
||
This value shall be included in the serial data. The defined identifier values are:
|
||
00h - Unknown or unspecified
|
||
01h - GBIC
|
||
02h - Module/connector soldered to motherboard
|
||
03h - 1310 SFP
|
||
04-0Ah - Reserved for XFP and other platforms
|
||
0Bh - DWDM SFP
|
||
80-FFh - Vendor specific."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.2,
|
||
SFP-8472 Table 3.1 and 3.2"
|
||
::= { sfpConfigEntry 2 }
|
||
|
||
sfpConfig1310ExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
modDef0(0), -- GBIC definition is not specified or not compliant with a defined MOD_DEF
|
||
modDef1(1), -- GBIC is compliant with MOD_DEF 1
|
||
modDef2(2), -- GBIC is compliant with MOD_DEF 2
|
||
modDef3(3), -- GBIC is compliant with MOD_DEF 3
|
||
modDef4(4), -- GBIC/SFP function is defined by serial ID only
|
||
modDef5(5), -- GBIC is compliant with MOD_DEF 5
|
||
modDef6(6), -- GBIC is compliant with MOD_DEF 6
|
||
modDef7(7) -- GBIC is compliant with MOD_DEF 7
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"The extended identifier value provides additional information about the 1310 transceiver.
|
||
The defined identifier values are:
|
||
00h GBIC definition is not specified or the GBIC
|
||
definition is not compliant with a defined
|
||
MOD_DEF. See product specification for details.
|
||
01h GBIC is compliant with MOD_DEF 1
|
||
02h GBIC is compliant with MOD_DEF 2
|
||
03h GBIC is compliant with MOD_DEF 3
|
||
04h GBIC/SFP function is defined by serial ID only
|
||
05h GBIC is compliant with MOD_DEF 5
|
||
06h GBIC is compliant with MOD_DEF 6
|
||
07h GBIC is compliant with MOD_DEF 7
|
||
08-FFh Reserved"
|
||
REFERENCE "SFP-8472 Table 3.1 and 3.3"
|
||
::= { sfpConfigEntry 3 }
|
||
|
||
sfpConfigWdmExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field is used to distinguish between different types of DWDM transceivers and
|
||
different power and environmental classes. The defined identifier values are:
|
||
Bits 7..6: Reserved
|
||
Bits 5..4: Class of WDM
|
||
00: no WDM
|
||
01: CWDM
|
||
10: DWDM
|
||
Bits 3..2: Class of power
|
||
00: P<1W
|
||
01: [1W,1.5W]
|
||
10: P>1.5W
|
||
11: reserved
|
||
Bits 3..2: Class of temp
|
||
00: [-5, 70C]
|
||
01: [1W,1.5W]
|
||
10: reserved
|
||
11: Defined by Bytes 15 - 16."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.3"
|
||
::= { sfpConfigEntry 4 }
|
||
|
||
sfpConfigConnectorCode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
conUnknown(0), -- Unknown or unspecified
|
||
conSc(1), -- SC
|
||
conFcCopper1(2), -- Fibre Channel Style 1 copper connector
|
||
conFcCopper2(3), -- Fibre Channel Style 2 copper connector
|
||
conBncTnc(4), -- BNC/TNC
|
||
conFcCoaxial(5), -- Fibre Channel coaxial headers
|
||
conFiberJack(6), -- FiberJack
|
||
conLc(7), -- LC
|
||
conMtRj(8), -- MT-RJ
|
||
conMu(9), -- MU
|
||
comSg(10), -- SG
|
||
conOpticalPigtail(11), -- Optical pigtail
|
||
conHssdc2(32), -- HSSDC II
|
||
conCopperPigtail(33) -- Optical pigtail
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The identifier value specifies the physical device described by the serial information.
|
||
This value shall be included in the serial data. The defined identifier values are:
|
||
00h - Unknown or unspecified
|
||
01h - SC
|
||
02h - Fibre Channel Style 1 copper connector
|
||
03h - Fibre Channel Style 2 copper connector
|
||
04h - BNC/TNC
|
||
05h - Fibre Channel coaxial headers
|
||
06h - FiberJack
|
||
07h - LC
|
||
08h - MT-RJ
|
||
09h - MU
|
||
0Ah - SG
|
||
0Bh - Optical pigtail
|
||
0Ch - 1Fh - Reserved
|
||
20h - HSSDC II
|
||
21h - Copper Pigtail
|
||
22h - 7Fh - Reserved
|
||
80-FFh - Vendor specific."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.4,
|
||
SFP-8472 Table 3.1 and 3.4."
|
||
::= { sfpConfigEntry 5 }
|
||
|
||
sfpConfigInfibandCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the Infiband interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: 1X SX
|
||
Bits 1: 1X LX
|
||
Bits 2: 1X Copper Active
|
||
Bits 3: 1X Copper Passive."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5."
|
||
::= { sfpConfigEntry 6 }
|
||
|
||
sfpConfigEsconCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only -- 1310
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the ESCON interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: ESCON MMF, 1310nm LED
|
||
Bits 1: ESCON SMF, 1310nm Laser"
|
||
REFERENCE "SFP-8472 Table 3.1 and 3.5."
|
||
::= { sfpConfigEntry 7 }
|
||
|
||
sfpConfigSonetCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the SONET interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: SONET reach specifier bit 1
|
||
Bits 1: SONET reach specifier bit 2
|
||
Where:
|
||
00 speed OC-3/OC-12/OC-48 Short reach - SONET SR compliant
|
||
10 speed OC-3/OC-12/OC-48 Short reach - SONET SR-1 compliant
|
||
10 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-1 compliant
|
||
01 speed OC-3/OC-12/OC-48 Intermediate reach - SONET IR-2 compliant
|
||
10 speed OC-3/OC-12/OC-48 Long reach - SONET LR-1 compliant
|
||
01 speed OC-3/OC-12/OC-48 Long reach - SONET LR-2 compliant
|
||
11 speed OC-3/OC-12/OC-48 Long reach - SONET LR-3 compliant
|
||
Bits 2: OC-48, single mode long reach
|
||
Bits 3: OC-48, single mode inter. reach
|
||
Bits 4: OC-48, multi-mode short reach
|
||
Bits 5: OC-12, single mode long reach
|
||
Bits 6: OC-12, single mode inter. reach
|
||
Bits 7: OC-12 multi-mode short reach
|
||
Bits 8: OC-3, single mode long reach
|
||
Bits 9: OC-3, single mode inter. reach
|
||
Bits 10: OC-3, multi-mode short reach."
|
||
REFERENCE "DWDM MSA Table 2.3.1, 2.3.5 and 2.3.5a,
|
||
SFP-8472 Table 3.1, 3.5 and 3.5a."
|
||
::= { sfpConfigEntry 8 }
|
||
|
||
sfpConfigGbeCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the Infiband interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: 1000BASE-T
|
||
Bits 1: 1000BASE-CX
|
||
Bits 2: 1000BASE-LX
|
||
Bits 3: 1000BASE-SX
|
||
Bits 4: 100BASE-LX/LX10 -- 1310
|
||
Bits 5: 100BASE-FX -- 1310
|
||
Bits 6: BASE-BX10 -- 1310
|
||
Bits 7: BASE-PX." -- 1310
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5"
|
||
::= { sfpConfigEntry 9 }
|
||
|
||
sfpConfigFcCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the FC interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
- Fibre Channel link length:
|
||
Bits 0: very long distance (V)
|
||
Bits 1: short distance (S)
|
||
Bits 2: intermediate distance (I)
|
||
Bits 3: long distance (L)
|
||
- Fibre Channel transmitter technology
|
||
Bits 4: Longwave laser (LC)
|
||
Bits 5: Electrical inter-enclosure (EL)
|
||
Bits 6: Electrical intra-enclosure (EL)
|
||
Bits 7: Shortwave laser w/o OFC (SN)
|
||
Bits 8: Shortwave laser w/ OFC (SL)
|
||
Bits 9: Longwave laser (LL)
|
||
Bits 10: Copper Active -- 1310
|
||
Bits 11: Copper Passive -- 1310
|
||
- Fibre Channel transmission media
|
||
Bits 12: Twin Axial Pair (TW)
|
||
Bits 13: Shielded Twisted Pair (TP)
|
||
Bits 14: Miniature Coax (MI)
|
||
Bits 15: Video Coax (TV)
|
||
Bits 16: Multi-mode, 62.5m (M6)
|
||
Bits 17: Multi-mode, 50 m (M5)
|
||
Bits 18: Single Mode (SM)
|
||
- Fibre Channel speed
|
||
Bits 19: 800 MB/Sec
|
||
Bits 20: 400 MB/Sec
|
||
Bits 21: 200 MB/Sec
|
||
Bits 22: 100 MB/Sec
|
||
Bits 23: 1200 MB/Sec
|
||
Bits 24: 1600 MB/Sec."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.5,
|
||
SFP-8472 Table 3.1 and 3.5"
|
||
::= { sfpConfigEntry 10 }
|
||
|
||
sfpConfigEncodingCode OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
encUnspecified(0), -- Unspecified
|
||
enc8B10B(1), -- 8B10B
|
||
enc4B5B(2), -- 4B5B
|
||
encNrz(3), -- NRZ
|
||
encManchester(4), -- Manchester
|
||
encSonet(5), -- SONET Scrambled
|
||
enc64B66B(6) -- 64B/66B
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encoding value indicates the serial encoding mechanism that is the
|
||
nominal design target of the particular transceiver.
|
||
The value shall be contained in the serial data.
|
||
The defined encoding values are:
|
||
00h: Unspecified
|
||
01h: 8B10B
|
||
02h: 4B5B
|
||
03h: NRZ
|
||
04h: Manchester
|
||
05h: SONET Scrambled
|
||
06h -FFh: Reserved."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.6,
|
||
SFP-8472 Table 3.1 and 3.6"
|
||
::= { sfpConfigEntry 11 }
|
||
|
||
sfpConfigNominalBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The nominal bit rate (BR, nominal) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second.
|
||
The bit rate includes those bits necessary to encode and delimit the
|
||
signal as well as those bits carrying data information.
|
||
A value of 0 indicates that the bit rate is not specified and must be
|
||
determined from the transceiver technology.
|
||
The actual information transfer rate will depend on the encoding of the data,
|
||
as defined by the encoding value."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 12 }
|
||
|
||
sfpConfigLength9mKm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Addition to EEPROM data from original GBIC definition.
|
||
This value specifies the link length that is supported by the transceiver while
|
||
operating in compliance with the applicable standards using single mode fiber.
|
||
A value of zero means that the transceiver does not support single mode
|
||
fiber or that the length information must be determined from the transceiver
|
||
technology."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 13 }
|
||
|
||
sfpConfigLength9m100m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using
|
||
single mode fiber.
|
||
The value is in units of 100 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 25.4 km.
|
||
A value of zero means that the transceiver does not support single mode
|
||
fiber or that the length information must be determined from the transceiver
|
||
technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 14 }
|
||
|
||
sfpConfigLength50m10m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using 50 micron
|
||
multi-mode fiber.
|
||
The value is in units of 10 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 2.54 km.
|
||
A value of zero means that the transceiver does not support 50 micron
|
||
multimode fiber or that the length information must be determined from the
|
||
transceiver technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 15 }
|
||
|
||
sfpConfigLength62m10m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using 62.5 micron
|
||
multi-mode fiber.
|
||
The value is in units of 10 meters. A value of 255 means that the transceiver
|
||
supports a link length greater than 2.54 km.
|
||
A value of zero means that the transceiver does not support 50 micron
|
||
multimode fiber or that the length information must be determined from the
|
||
transceiver technology.
|
||
It is common for the transceiver to support both 50 micron and 62.5 micron
|
||
fiber."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 16 }
|
||
|
||
sfpConfigLengthCopper1m OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 1310
|
||
DESCRIPTION
|
||
"This value specifies the link length that is supported by the transceiver
|
||
while operating in compliance with the applicable standards using copper cable.
|
||
The value is in units of 1 meter. A value of 255 means that the transceiver
|
||
supports a link length greater than 254 meters.
|
||
A value of zero means that the transceiver does not support copper cables
|
||
or that the length information must be determined from the
|
||
transceiver technology."
|
||
REFERENCE "SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 17 }
|
||
|
||
sfpConfigMaxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the maximum operating case temperature the module is
|
||
rated for. The maximum case temperature is encoded as a signed two<77>s
|
||
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
|
||
This field should be used even if a standard operating temperature class
|
||
is indicated in the Extended Indentifier Byte (Byte 1)."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 18 }
|
||
|
||
sfpConfigMinTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the minimum operating case temperature the module is
|
||
rated for. The maximum case temperature is encoded as a signed two<77>s
|
||
complement value in <20>C, yielding a total range of <20>128C to +127<32>C.
|
||
This field should be used even if a standard operating temperature class
|
||
is indicated in the Extended Indentifier Byte."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 19 }
|
||
|
||
sfpConfigMaxSupplyCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"This field defines the maximum supply current the module will consume
|
||
under worst case conditions. The maximum current is the byte value * 4mA."
|
||
REFERENCE "DWDM MSA Table 2.3.1."
|
||
::= { sfpConfigEntry 20 }
|
||
|
||
sfpConfigChannelSpacing OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"In the case of SFP:
|
||
This bit field value identifies the densest channel spacing
|
||
the module is compatible with and the number of channels over which the
|
||
module may be tuned by user command.
|
||
If not tunable, the number of channels is entered as 1.
|
||
The bit fields are:
|
||
Bits 7..6: Channel Spacing
|
||
00: 200 GHz (DWDM)
|
||
01: 100 GHz (DWDM)
|
||
10: 50 Ghz (DWDM)
|
||
11: Reserved
|
||
Bits 5..0: Number of channels (1 <20> 63).
|
||
In the case of XFP:
|
||
The value of this field is equal to the guaranteed range of laser
|
||
wavelength (+/- value) from Nominal wavelength.
|
||
(Wavelength Tol. = value/200 in nm)"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.7. XFP INF-8077i Section 5.34."
|
||
::= { sfpConfigEntry 21 }
|
||
|
||
sfpConfigVendorName OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor name is a 16 character field that contains ASCII characters,
|
||
left-aligned and padded on the right with ASCII spaces (20h).
|
||
The vendor name shall be the full name of the corporation,
|
||
a commonly accepted abbreviation of the name of the corporation,
|
||
the SCSI company code for the corporation, or the stock exchange code
|
||
for the corporation.
|
||
At least one of the vendor name or the vendor OUI fields shall contain
|
||
valid serial data."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 22 }
|
||
|
||
sfpConfigOptionalWdm OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The bits in the option field shall specify the options implemented
|
||
in the transceiver. The following bits are defined:
|
||
Bits 7: Optional Interrupt Pin Functionality Supported (1 if supported)
|
||
Bits 6..4: Pilot Tone Functionality
|
||
000b: No Pilot Tone Functionality
|
||
001b: Pilot Tone Detection Only
|
||
010b: Pilot Tone Injection Only
|
||
011b: Pilot Tone Injection and Detection
|
||
100b: Enhanched Pilot Tone Functionality
|
||
101b-111b: Reserved
|
||
Bits 3: Variable Optical Attenuator Implemented (1 if implemented)
|
||
Bits 2: Extended Transmit Power Monitoring
|
||
0: Default (SFF-8472) TX Power Monitoring
|
||
1: Extended TX Power Monitoring (+18.2 dBm max)
|
||
Bits 1: Wavelength Monitor Type in A2 Byte 106-107
|
||
0: Monitor is Wavelength
|
||
1: Monitor is Laser Temperature
|
||
Bits 0: Variable Decision Threshold (1 if implemented)"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.8."
|
||
::= { sfpConfigEntry 23 }
|
||
|
||
sfpConfigVendorOUI OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor organizationally unique identifier field (vendor OUI)
|
||
is a 3-byte field that contains the IEEE Company Identifier for the
|
||
vendor. A value of all zero in the 3-byte field indicates that
|
||
the Vendor OUI is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 24 }
|
||
|
||
sfpConfigVendorPN OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor part number (vendor PN) is a 16-byte field that contains
|
||
ASCII characters, left-aligned and padded on the right with ASCII
|
||
spaces (20h), defining the vendor part number or product name.
|
||
A value of all zero in the 16-byte field indicates that the
|
||
vendor PN is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 25 }
|
||
|
||
sfpConfigVendorRev OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..4))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor revision number (vendor rev) is a 4-byte field that
|
||
contains ASCII characters, left-aligned and padded on the right with
|
||
ASCII spaces (20h), defining the vendor<6F>s product revision number.
|
||
A value of all zero in the 4-byte field indicates that
|
||
the vendor PN is unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 26 }
|
||
|
||
sfpConfigWaveLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"In the case of DWDM:
|
||
Nominal transmitter output wavelength in units of 0.01nm.
|
||
As an example, a wavelength of 1550.51nm would be encoded as: 155051.
|
||
In the case of 1310:
|
||
The laser wavelength is equal to the the integer value in nm with 00 at
|
||
the end.
|
||
As an example, a wavelength of 1310 would be encoded as: 131000."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 27 }
|
||
|
||
-- Extended ID Fields
|
||
|
||
sfpConfigExtendedOptions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Specify the bitmap options implemented in the transceiver as described in.
|
||
The bits definition is:
|
||
5 RATE_SELECT is implemented
|
||
NOTE: Lack of implemention does not indicate lack of
|
||
simultaneous compliance with multiple standard rates.
|
||
Compliance with particular standards should be determined
|
||
from Transceiver Code.
|
||
4 TX_DISABLE is implemented and disables the serial output.
|
||
3 TX_FAULT signal implemented. (See SFP MSA)
|
||
2 Loss of Signal implemented, signal inverted from standard
|
||
definition in SFP MSA.
|
||
NOTE: This is not standard SFP/GBIC behavior and should
|
||
be avoided, since non-interoperable behavior results.
|
||
1 Loss of Signal implemented, signal as defined in SFP MSA."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.9, SFP-8472 Table 3.1 and 3.7."
|
||
::= { sfpConfigEntry 28 }
|
||
|
||
sfpConfigMaxBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The upper bit rate limit at which the transceiver will still meet its
|
||
specifications (BR, max) is specified in units of 1% above the nominal
|
||
bit rate.
|
||
A value of zero indicates that this field is not specified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 29 }
|
||
|
||
sfpConfigMinBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The lower bit rate limit at which the transceiver will still meet its
|
||
specifications (BR, min) is specified in units of 1% below the nominal
|
||
bit rate.
|
||
A value of zero indicates that this field is not specified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 30 }
|
||
|
||
sfpConfigVendorSN OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (0..16))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The vendor serial number (vendor SN) is a 16 character field that
|
||
contains ASCII characters, left-aligned and padded on the right with
|
||
ASCII spaces (20h), defining thevendor<6F>s serial number for the transceiver.
|
||
A value of all zero in the 16-byte field indicates that the vendor PN is
|
||
unspecified."
|
||
REFERENCE "DWDM MSA Table 2.3.1, SFP-8472 Table 3.1."
|
||
::= { sfpConfigEntry 31 }
|
||
|
||
sfpConfigDateCode OBJECT-TYPE
|
||
SYNTAX SnmpAdminString (SIZE (6))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The date code is an 6-byte field that contains the vendor<6F>s date
|
||
code in ASCII characters. The date code is mandatory.
|
||
The date code shall be in the format: <yy><mm><dd>."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.10, SFP-8472 Table 3.1 and 3.8."
|
||
::= { sfpConfigEntry 32 }
|
||
|
||
sfpConfigDiagnosticMonitoring OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A field with 8 single bit indicators which describe the
|
||
optional digital diagnostic features implemented in the transceiver.
|
||
Since transceivers will not necessarily implement all optional
|
||
features described in this document, the <20>Enhanced Options<6E> bit field
|
||
allows the host system to determine which functions are
|
||
available over the 2 wire serial bus.
|
||
The bits assignment is:
|
||
7 Reserved for legacy diagnostic implementations.
|
||
Must be <20>0<EFBFBD> for compilance with this document.
|
||
6 Digital diagnostic monitoring implemented (described in this document).
|
||
Must be <20>1<EFBFBD> for compliance with this document.
|
||
5 Internally Calibrated
|
||
4 Externally Calibrated
|
||
3 Received power measurement type 0 = OMA, 1 = Average Power
|
||
2 Address change required."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.11, SFP-8472 Table 3.1 and 3.9."
|
||
::= { sfpConfigEntry 33 }
|
||
|
||
sfpConfigEnhanceOptions OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A field with 6 single bit indicators which describe the
|
||
optional digital diagnostic features implemented in the transceiver.
|
||
Since transceivers will not necessarily implement all optional features
|
||
described in this document, the <20>Enhanced Options<6E> bit field allows the
|
||
host system to determine which functions are available over the 2 wire
|
||
serial bus. A <20>1<EFBFBD> indicates that the particular function is
|
||
implemented in the transceiver..
|
||
The bits assignment is:
|
||
Bits 7: Optional Alarm/warning flags implemented for all monitored quantities
|
||
Bits 6: Optional Soft TX_DISABLE control and monitoring implemented
|
||
Bits 5: Optional Soft TX_FAULT monitoring implemented
|
||
Bits 4: Optional Soft RX_LOS monitoring implemented
|
||
Bits 3: Option not enabled in DWDM.
|
||
8472- Optional Soft RATE_SELECT control and monitoring implemented
|
||
Bits 2: Option not enabled in DWDM.
|
||
8472- Optional Application Select control implemented per SFF-8079"
|
||
REFERENCE "DWDM MSA Table 2.3.1 and Table 2.3.12, SFP-8472 Table 3.1 and 3.10."
|
||
::= { sfpConfigEntry 34 }
|
||
|
||
sfpConfig8472Compliance OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
noDiag(0),
|
||
rev93(1),
|
||
rev94(2)
|
||
}
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An unsigned integer that indicates which feature set(s) are
|
||
implemented in the transceiver.
|
||
The defined values are:
|
||
0 - Digital diagnostic functionality not included or undefined.
|
||
1 - Includes functionality described in Rev 9.3 SFF-8472.
|
||
2 - Includes functionality described in Rev 9.4 SFF-8472."
|
||
REFERENCE "DWDM MSA Table 2.3.1 and 2.3.14, SFP-8472 Table 3.1 and 3.12."
|
||
::= { sfpConfigEntry 35 }
|
||
|
||
sfpConfigTunableWaveLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Wavelength Tuning Control.
|
||
The availability of this function is indicated in the object sfpConfigChannelSpacing,
|
||
where number of channels greater than 1 indicates tunability.
|
||
The wavelength is set to the channel number written to this byte.
|
||
For a value of 0, channel 1 is selected. For values greater than the maximum channel number,
|
||
the maximum channel number is selected.
|
||
The object value is defaults to 1 on power-up."
|
||
REFERENCE "DWDM MSA Table 2.3.27."
|
||
::= { sfpConfigEntry 36 }
|
||
|
||
sfpConfigVoaControl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Variable Optical Attenuator Control.
|
||
Used to control the wavelength in tunable modules.
|
||
The availability of this function is indicated in Bit 3 of sfpConfigOptionalWdm.
|
||
The amount of attenuation set is given by the Byte value * 0.1 dB,
|
||
and thus ranges from 0 to 25.6 dB.
|
||
The object value defaults to 0 on power-up."
|
||
REFERENCE "DWDM MSA Table 2.3.28."
|
||
::= { sfpConfigEntry 37 }
|
||
|
||
sfpConfigVdtControl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Variable Decision Threshold Control.
|
||
Used to control the variable decision threshold function.
|
||
The availability of this function is indicated in Bit 0 of sfpConfigOptionalWdm.
|
||
The object value is a 2<>s complement 7 bit value (-128 - +127).
|
||
The decision threshold set is given by:
|
||
Decision Threshold = 50% + [VAL/256]*100%
|
||
The object value defaults to 0 on power-up corresponding to 50%."
|
||
REFERENCE "DWDM MSA Table 2.3.29."
|
||
::= { sfpConfigEntry 38 }
|
||
|
||
sfpConfigPilotToneModulation OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Pilot Tone Injection Modulation Depth.
|
||
When basic MSA pilot tone injection functionality is implemented
|
||
(as indicated in the Serial ID fields by bits 4-6 of of sfpConfigOptionalWdm)
|
||
Tjis object may be used by the vendor to indicate modulation
|
||
depth per unit control swing on pin 7.
|
||
The modulation depth per control swing is given by:
|
||
Modulation Depth = 0.2% * VAL / Vpp(pin7)
|
||
A value of 0 indicates that the modulation depth per input swing
|
||
is within the range"
|
||
REFERENCE "DWDM MSA Table 2.3.30."
|
||
::= { sfpConfigEntry 39 }
|
||
|
||
sfpConfigCleiCode OBJECT-TYPE
|
||
SYNTAX DisplayString (SIZE (10))
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The COMMON LANGUAGE Equipment Code.
|
||
The CLEI code contains an intelligent
|
||
ten-character code that identifies the
|
||
telecommunications equipment.
|
||
The Clei Code resides in the SEEP of the SFP."
|
||
REFERENCE
|
||
"GR-383-CORE"
|
||
::= { sfpConfigEntry 40 }
|
||
|
||
--
|
||
-- XFP Information
|
||
--
|
||
|
||
sfpConfigXfpExtXcvrId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current -- xfp
|
||
DESCRIPTION
|
||
"This field is used to distinguish between different types of DWDM transceivers and
|
||
different power and environmental classes. The defined identifier values are:
|
||
Bits 7..6:
|
||
00: Power Level 1 Module (1.5 W max. power dissipation.)
|
||
01: Power Level 2 Module (2.5W Max)
|
||
10: Power Level 3 Module (3.5W max. power dissipation.)
|
||
11: Power Level 4 Module (>3.5W max. power dissipation.)
|
||
Bit 5: CDR exist
|
||
0: Module with CDR function
|
||
1: Non-CDR version of XFP
|
||
Bits 5: TX ref clock is required
|
||
0: TX Ref Clock Input Required
|
||
1: TX Ref Clock Input Not Required
|
||
Bits 3: CLEI code is present
|
||
0: No CLEI code present in Table 02h
|
||
1: CLEI code present in Table 02h
|
||
Bits 2..0: Resesrved"
|
||
REFERENCE "XFP INF-8077i Table 47."
|
||
::= { sfpConfigEntry 41 }
|
||
|
||
sfpConfigXfpEncodingCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The encoding value indicates the serial encoding mechanism that is the
|
||
nominal design target of the particular transceiver.
|
||
The value shall be contained in the serial data.
|
||
The defined encoding values are:
|
||
Bit 7: 64B/66B
|
||
Bit 6: 8B/10B
|
||
Bit 5: SONET scrambled
|
||
Bit 4: NRZ
|
||
Bit 3: RZ
|
||
Bits 2-0: Reserved."
|
||
REFERENCE "XFP INF-8077i Table 50."
|
||
::= { sfpConfigEntry 42 }
|
||
|
||
sfpConfigXfpMinBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The minimum bit rate (BR, minimum) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second. The bit
|
||
rate includes those bits necessary to encode and delimit the signal as well
|
||
as those bits carrying data information. A value of 0 indicates that the minimum
|
||
bit rate is not specified andmust be determined from the transceiver
|
||
technology. The actual information transfer rate will depend on the encoding
|
||
of the data, as defined by the encoding value. Specific CDR rate
|
||
support is indicated in Byte 164."
|
||
REFERENCE "XFP INF-8077i Section 5.20."
|
||
::= { sfpConfigEntry 43 }
|
||
|
||
sfpConfigXfpMaxBitRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The maximum bit rate (BR, maximum) is specified in units of 100 Megabits
|
||
per second, rounded off to the nearest 100 Megabits per second. The
|
||
bit rate includes those bits necessary to encode and delimit the signal as
|
||
well as those bits carrying data information. A value of 0 indicates that the
|
||
maximum bit rate is not specified and must be determined from the transceiver
|
||
technology. The actual information transfer rate will depend on the
|
||
encoding of the data, as defined by the encoding value. Specific CDR rate
|
||
support is indicated in Byte 164."
|
||
REFERENCE "XFP INF-8077i Section 5.21."
|
||
::= { sfpConfigEntry 44 }
|
||
|
||
sfpConfig10GSonetCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the SONET interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0-1: Reserved
|
||
Bits 2: I-64.5 - 1550 nm, 25 km, SM, IO
|
||
Bits 3: I-64.3 - 1550 nm, 25 km, SM, IO
|
||
Bits 4: I-64.2 - 1550 nm, 25 km, SM, IO
|
||
Bits 5: I-64.2r - 1550 nm, 2 km, SM, VSR
|
||
Bits 6: I-64.1/VSR2000-2R1/P1I1-2D1 - 1310 nm, 2 km, SM, VSR
|
||
Bits 7: I-64.1r/VSR600-2R1 - 1310 nm, 0.6 km, Laser-MM Fibre-SM, VSR
|
||
Bits 8: Reserved
|
||
Bits 9: S-64.5b - 1550 nm, 40 km, SH
|
||
Bits 10: S-64.5a - 1550 nm, 40 km, SH
|
||
Bits 11: S-64.3b
|
||
Bits 12: S-64.3a - 1550 nm, 40 km, SM, SH
|
||
Bits 13: S-64.2b - 1550 nm, 40 km, SM, SH
|
||
Bits 14: S-64.2a - 1550 nm, 40 km, SM, SH
|
||
Bits 15: S-64.1 - 1310 nm, 20 km, IO
|
||
Bits 16-17: Reserved
|
||
Bits 18: G.959.1 P1L1-2D2 - 1550 nm, SM, 80 km, LH
|
||
Bits 19: L-64.3 - 1550 nm, 80 km, LH
|
||
Bits 20: L-64.2c - 1550 nm, 80 km, LH
|
||
Bits 21: L-64.2b - 1550 nm, 80 km, LH
|
||
Bits 22: L-64.2a - 1550 nm, 80 km, LH
|
||
Bits 23: L-64.1 - 1310 nm, SM, 40 km, SH
|
||
Bits 24-28: Reserved
|
||
Bits 29: V-64.3 - 1550 nm, SM, 120 km, VL
|
||
Bits 30: V-64.2b - 1550 nm, SM, 120 km, VL
|
||
Bits 31: V-64.2a - 1550 nm, SM, 120 km, VL."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 45 }
|
||
|
||
sfpConfig10GbeCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the 10GbE interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
Bits 0: Reserved
|
||
Bits 1: 10GBASE-EW - WAN, 1550 nm, SM, ER
|
||
Bits 2: 10GBASE-LW - WAN, 1310 nm, SM, LR
|
||
Bits 3: 10GBASE-SW - WAN, 850 nm, MM, SR
|
||
Bits 4: 10GBASE-LRM (Long reach Multimode) - LAN, 1310 nm, MM, SR fiber, 0.2 km, SR
|
||
Bits 5: 10GBASE-ER (extended range) - LAN, 1550 nm, SM, 40 km, ER
|
||
Bits 6: 10GBASE-LR (Long Range) - LAN, 1310 nm, SM, 10 km, LR
|
||
Bits 7: 10GBASE-SR - LAN, 850 nm, MM, 0.3 km, SR."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 46 }
|
||
|
||
sfpConfig10GFcCompliance OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the 10GFC interfaces
|
||
that are supported by the transceiver. The defined identifier values are:
|
||
- Fibre Channel link length:
|
||
Bits 0-3: Reserved
|
||
Bits 4: Intermediate Reach 1300 nm FP - 1310 nm, SM, IR
|
||
Bits 5: Extended Reach 1550 nm - 1550 nm, SM, ER
|
||
Bits 6: 1200-SM-LL-L - 1310 nm, SM, LR
|
||
Bits 7: 1200-MX-SN-I - 850 nm, MM, IR."
|
||
REFERENCE "XFP MSA Table 49."
|
||
::= { sfpConfigEntry 47 }
|
||
|
||
sfpConfigXfpDeviceTech OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The following bit significant indicators define the XFP device technology:
|
||
Bits 0: 0-Transmitter not Tunable 1-Transmitter Tunable
|
||
Bits 1: Detector Type: 0-PIN detector 1-APD detector
|
||
Bits 2: Cooled transmitter
|
||
Bits 3: Wavelength control: 0-No wavelength control 1-Active wavelength control
|
||
Bits 4-7: Transmitter technology:
|
||
0000b 850 nm VCSEL
|
||
0001b 1310 nm VCSEL
|
||
0010b 1550 nm VCSEL
|
||
0011b 1310 nm FP
|
||
0100b 1310 nm DFB
|
||
0101b 1550 nm DFB
|
||
0110b 1310 nm EML
|
||
0111b 1550 nm EML
|
||
1000b Copper or others
|
||
1001b 1550 nm tunable
|
||
1111b-1001b Reserved."
|
||
REFERENCE "XFP MSA Table 51 and Table 52."
|
||
::= { sfpConfigEntry 48 }
|
||
|
||
sfpConfigXfpTuningSupported OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Indicate the XFP tuning support:
|
||
Bit1: wavelenght (Tunable DWDM - selection in 50 pm steps)
|
||
Bit2: frequency (Tunable DWDM - selection by channel number)
|
||
For exmaple the value 0 means no support, and 3 means both."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 49 }
|
||
|
||
sfpConfigXfpDesiredChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer 1 to N (N=Number of Channels)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 50 }
|
||
|
||
sfpConfigXfpDesiredWl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of Wavelength setpoint (in units of 50 picometers)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 51 }
|
||
|
||
sfpConfigXfpWlError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Monitor of Current Wavelength Error(in units of 5 picometers)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 52 }
|
||
|
||
sfpConfigXfpDesiredFreq OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer to N (N=Number of Channels)."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 53 }
|
||
|
||
sfpConfigXfpFreqError OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Frequency error reported in 16 bit signed integer with LSB=0.1 GHz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 54 }
|
||
|
||
sfpConfigXfpDitherSupported OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Tx Dither Supported."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 55 }
|
||
|
||
sfpConfigXfpDitherAdmin OBJECT-TYPE
|
||
SYNTAX INTEGER {
|
||
up(1), -- enable
|
||
down(2) -- disable
|
||
}
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable the dithering function."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 56 }
|
||
|
||
sfpConfigXfpCapFreqFirstThz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers First Frequency (THz) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 57 }
|
||
|
||
sfpConfigXfpCapFreqFirst10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers First Frequency (GHz*10) capability.
|
||
This value should be added to sfpConfigXfpCapFreqFirstThz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 58 }
|
||
|
||
sfpConfigXfpCapFreqLastThz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers Last Frequency (THz) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 59 }
|
||
|
||
sfpConfigXfpCapFreqLast10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers Last Frequency (GHz*10) capability.
|
||
This value should be added to sfpConfigXfpCapFreqLastThz."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 60 }
|
||
|
||
sfpConfigXfpCapMaxSpacing10Ghz OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Lasers maximum supported grid spacing (GHz*10) capability."
|
||
REFERENCE "SFP-8477."
|
||
::= { sfpConfigEntry 61 }
|
||
|
||
sfpConfigXfpCalibrationSupported OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Calibarion Supported."
|
||
::= { sfpConfigEntry 62 }
|
||
|
||
sfpConfigXfpCalibrationEnabled OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Enable/Disable the calibration process.
|
||
Changing the value to Enable when a signal exist invokes an immidiate calibration process.
|
||
Changing the value to Disable returns the calibration values to defaults."
|
||
::= { sfpConfigEntry 63 }
|
||
|
||
--
|
||
-- CFP Information
|
||
--
|
||
|
||
sfpConfigCfpExtId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended Identifier bit fields:
|
||
Bits 7-6 - Power Class:
|
||
00b: Power Class 1 Module (? 8 W max),
|
||
01b: Power Class 2 Module (?16 W max),
|
||
10b: Power Class 3 Module (? 24 W max),
|
||
11b: Power Class 4 Module (? 32 W max).
|
||
Bits 5-4 Lane Ratio:
|
||
00b: Network lane : Host lane = 1 : n (Mux type),
|
||
01b: Network lane : Host lane = n : m (Gear Box type),
|
||
10b: Network lane : Host lane = n : n (Parallel type),
|
||
11b: Reserved
|
||
Bits 3-1 WDM Type:
|
||
000b: Non-WDM,
|
||
001b: CWDM,
|
||
010b: LANWDM,
|
||
011b: DWDM on 200G-grid,
|
||
100b: DWDM on 100G-grid,
|
||
101b: DWDM on 50G-grid,
|
||
110b: DWDM on 25G-grid,
|
||
111b: Other type WDM
|
||
Bit 0 CLEI Presence:
|
||
0: No CLEI code present,
|
||
1: CLEI code present"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 70 }
|
||
|
||
sfpConfigCfpConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Connector Type Code:
|
||
00h: Undefined,
|
||
01h : SC,
|
||
07h : LC,
|
||
08h : MT-RJ,
|
||
09h : MPO,
|
||
Other Codes : Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 71 }
|
||
|
||
sfpConfigCfpEthernetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Ethernet Application Code.
|
||
00h: Undefined type,
|
||
01h: 100GE SMF 10km, 100GE-LR4,
|
||
02h: 100GE SMF 40km, 100GE-ER4,
|
||
03h: 100GE MMF 100m OM3, 100GE-SR10,
|
||
04h: For future use,
|
||
05h: 40GE SMF 10km, 40GE-LR4,
|
||
07h: 40GE MMF 100m OM3, 40GE-SR4,
|
||
For future use:
|
||
100G G.959.1 OTU4
|
||
40G G.693 SDH
|
||
40G G.693 OTU3
|
||
40G G.695 SDH
|
||
40G G.695 OTU3,
|
||
0Dh: 40GE-CR4 Copper
|
||
0Eh: 100GE-CR10 Copper,
|
||
0Fh: 40G BASE-FR,
|
||
10h~FFh: Reserved."
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 72 }
|
||
|
||
sfpConfigCfpFcCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Fiber Channel Application Code: Undefined"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 73 }
|
||
|
||
sfpConfigCfpCopperCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Copper Link Application Code: Undefined"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 74 }
|
||
|
||
sfpConfigCfpSonetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SONET/SDH Application Code:
|
||
00h: Undefined type,
|
||
01h: VSR2000-3R2,
|
||
02h: VSR2000-3R3,
|
||
03h: VSR2000-3R5,
|
||
04h ~ 0FFh: Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 75 }
|
||
|
||
sfpConfigCfpOtnCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"OTN Application Code:
|
||
0h: Undefined type,
|
||
01h: VSR2000-3R2F,
|
||
02h: VSR2000-3R3F,
|
||
03h: VSR2000-3R5F,
|
||
04h: VSR2000-3L2F,
|
||
05h: VSR2000-3L3F,
|
||
06h: VSR2000-3L5F,
|
||
07h: C4S1-2D1 (OTL3.4),
|
||
08h: 4I1-9D1F (OTL4.4),
|
||
09h ~ 0FFh: Reserved"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 76 }
|
||
|
||
sfpConfigCfpSupportedRates OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Additional Capable Rates Supported Bitmap:
|
||
Bits 7-5 - Reserved
|
||
Bit 4 - 111.8 Gbps
|
||
Bit 3 - 103.125 Gbps
|
||
Bit 2 - 41.25 Gbps
|
||
Bit 1 - 43 Gbps
|
||
Bit 0 - 39.8 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 77 }
|
||
|
||
sfpConfigCfpSupportedLanes OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Number of Lanes Supported:
|
||
Bits 7-4 - Number of Network Lanes
|
||
The value of 0 represents 16 network lanes supported.
|
||
The values of 1 through 15 represent the actual number of network lanes supported
|
||
Bits 3-0 - Number of Host Lanes
|
||
The value of 0 represents 16 network lanes supported.
|
||
The values of 1 through 15 represent the actual number of network lanes supported"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 78 }
|
||
|
||
sfpConfigCfpMediaProperties OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Media Properties bit fields:
|
||
Bits 7 - 6 Media Type:
|
||
00b: SMF ,
|
||
01b: MMF (OM3),
|
||
10b: Reserved,
|
||
11b: Copper
|
||
Bit 5 - Directionality:
|
||
0: Normal,
|
||
1: BiDi
|
||
Bit 4 Optical Multiplexing and De-multiplexing:
|
||
0: Without optical MUX/DEMUX,
|
||
1: With optical MUX/DEMUX
|
||
Bits 3 - 0 ctive Fiber per Connector:
|
||
A 4-bit unsigned number representing number of active fibers for TX and RX per connector:
|
||
0: 16 TX Lanes and 16 RX Lanes,
|
||
1: 1 TX Lane and 1 RX Lane,
|
||
4: 4 TX Lanes and 4 RX Lanes,
|
||
10: 10 TX Lanes and 10 RX Lanes,
|
||
12: 12 TX Lanes and 12 RX Lanes"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 79 }
|
||
|
||
sfpConfigCfpMaxNetworkLaneRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Network Lane Bit Rate: 8-bit value x 0.2 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 80 }
|
||
|
||
sfpConfigCfpMaxHostLaneRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Host Lane Bit Rate: 8-bit value x 0.2 Gbps"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 81 }
|
||
|
||
sfpConfigCfpMaxSmFiberLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Single Mode Optical Fiber Length:
|
||
8-bit value x 1 km for single mode fiber length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 82 }
|
||
|
||
sfpConfigCfpMaxMmFiberLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Multi-Mode Optical Fiber Length:
|
||
8-bit value x 10 m for multi-mode fiber length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 83 }
|
||
|
||
sfpConfigCfpMaxCopperCableLength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Copper Cable Length:
|
||
8-bit value x 1 m for copper cable length"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 84 }
|
||
|
||
sfpConfigCfpMinWavelenPerActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Minimum Wavelength per Active Fiber:
|
||
16-bit unsigned value x 0.025 nm.
|
||
(MSB is at 8012h, LSB is at 8013h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 85 }
|
||
|
||
sfpConfigCfpMaxWavelenPerActive OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum Wavelength per Active Fiber:
|
||
16-bit unsigned value x 0.025 nm.
|
||
(MSB is at 8014h, LSB is at 8015h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 86 }
|
||
|
||
sfpConfigCfpMaxLenOpticalWidth OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum per Lane Optical Width:
|
||
Guaranteed range of laser wavelength.
|
||
16-bit unsigned value x 1 pm.
|
||
(MSB is at 8016h, LSB is at 8017h)"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 87 }
|
||
|
||
sfpConfigCfpSpacing OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The spacing between two lanes:
|
||
0- unknown spacing
|
||
1 - 100G spacing
|
||
2 - 50G spacing
|
||
3- 25G spacing"
|
||
REFERENCE "CFP MSA 1.4"
|
||
::= { sfpConfigEntry 88 }
|
||
|
||
--
|
||
-- QSFP+ Information
|
||
--
|
||
|
||
sfpConfigQsfppEthernetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximum per Lane Optical Width:
|
||
Guaranteed range of laser wavelength.
|
||
16-bit unsigned value x 1 pm.
|
||
(MSB is at 8016h, LSB is at 8017h)"
|
||
REFERENCE "QSFP+ SFF-8436"
|
||
::= { sfpConfigEntry 100 }
|
||
|
||
sfpConfigQsfppSonetCode OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The spacing between two lanes:
|
||
0- unknown spacing
|
||
1 - 100G spacing
|
||
2 - 50G spacing
|
||
3- 25G spacing"
|
||
REFERENCE "QSFP+ SFF-8436"
|
||
::= { sfpConfigEntry 101 }
|
||
|
||
--
|
||
-- CXP Information
|
||
--
|
||
|
||
sfpConfigCxpExtId OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Extended Identifier (Byte 129):
|
||
Bits 7-5 - Power Class:
|
||
000: 0.25W max - Class 0
|
||
001: 1.0W max - Class 1
|
||
010: 1.5W max - Class 2
|
||
011: 2.5W max - Class 3
|
||
100: 4.0W max - Class 4
|
||
101: 6.0W max - Class 5
|
||
110: >6.0W - Class 6
|
||
111: Reserved
|
||
Bits 4 Tx CDR Presence:
|
||
1: Tx CDR provided
|
||
0: Otherwise
|
||
Bits 3 Rx CDR Presence:
|
||
1: Rx CDR provided;
|
||
0: Otherwise"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 110 }
|
||
|
||
sfpConfigCxpConnectorType OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Connector Type Code (Byte 130):
|
||
30h: Passive Copper Cable Assembly
|
||
31h: Active Copper Cable Assembly (ref. Byte 147)
|
||
32h: Active Optical Cable Assembly
|
||
33h: Optical Transceiver w/ optical connector"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 111 }
|
||
|
||
sfpConfigCxpMaxSupportedRate OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Max per-channel bit rate (Byte 134):
|
||
Max signal rate = binary value x 100 Mb/s"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 112 }
|
||
|
||
sfpConfigCxpNominalWavelength OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Wavelength/Attenuation (Bytes 135-136):
|
||
Optical: Nominal Laser Wavelength --
|
||
Wavelength in nm = value / 20): e.g. 42h 04h = 16,900, 16,900/20 = 845 nm
|
||
Copper: Nominal attenuation of cable either to the other end (passive) or to equalizer (active)
|
||
Byte 135:
|
||
Attenuation at 2.5 GHz in dB -
|
||
00h=no info
|
||
Byte 136:
|
||
Attenuation at 5 GHz in dB -
|
||
00h=no info"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 113 }
|
||
|
||
sfpConfigCxpDeviceTech OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Device Technology (Byte 147):
|
||
Bits 7-4 (Device Technology):
|
||
0000: 850 nm VCSEL
|
||
0001:1310 nm VCSEL
|
||
0010:1550 nm VCSEL
|
||
0011: 1310 nm FP
|
||
0100:1310 nm DFB
|
||
0101:1550 nm DFB
|
||
0110: 1310 nm EML
|
||
0111: 1550 nm EML
|
||
1000: Copper or others
|
||
11001: 1490 nm DFB
|
||
1010: Copper cable un-equalized
|
||
1011: Copper cable passive equalized
|
||
1100: Copper cable near & far end active equalizers
|
||
1101: Copper cable, far end active equalizer
|
||
1110: copper cable, near end active equalizer
|
||
1111: Reserved
|
||
Bit 3 (Wavelength Control):
|
||
0: No control
|
||
1: Active wavelength control
|
||
Bit 2 (Transmitter cooling):
|
||
0: Uncooled transmitter
|
||
1: Cooled transmitter
|
||
Bit 1 (Optical Detector):
|
||
0: P-I-N Detector
|
||
1: APD detector
|
||
Bit 0 (Optical Tunability):
|
||
0: Transmitter not tunable
|
||
1:Transmitter tunable"
|
||
REFERENCE ""
|
||
::= { sfpConfigEntry 114 }
|
||
|
||
|
||
--
|
||
-- Coherent Information
|
||
--
|
||
|
||
sfpConfigCohRxDesiredChannel OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of RX channel number, which is an integer 1 to N (N=Number of Channels)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 115 }
|
||
|
||
sfpConfigCohRxDesiredWl OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of RX Wavelength setpoint (in units of 50 picometers)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 116 }
|
||
|
||
sfpConfigCohRxDesiredFreq OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"User input of channel number, which is an integer to N (N=Number of Channels)."
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 117 }
|
||
|
||
sfpConfigCohCurrentCD OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current Chromatic Dispersion counter. Units are in ps/nm"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 118 }
|
||
|
||
sfpConfigCohCurrentOSNR OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Current SNR. Units are in 0.1dB"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 119 }
|
||
|
||
sfpConfigCohAverageOSNR OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Average SNR over PM interval. Units are in 0.1dB"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 120 }
|
||
|
||
sfpConfigCohMaxCD OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Maximal Chromatic Dispersion counter. Units are in ps/nm"
|
||
REFERENCE "CFP MSA"
|
||
::= { sfpConfigEntry 121 }
|
||
|
||
sfpConfigNyquist OBJECT-TYPE
|
||
SYNTAX TruthValue
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Nyquist - True (ON) or False (OFF). Default is OFF"
|
||
::= { sfpConfigEntry 122 }
|
||
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Diagnostic Table
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpDiagTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF SfpDiagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The SFP diagnostic table.
|
||
The table defines the status and control of the alarms and warnings
|
||
of the SFP-1310 and the DWDM SFP-15xy modules."
|
||
::= { sfpDiag 1 }
|
||
|
||
sfpDiagEntry OBJECT-TYPE
|
||
SYNTAX SfpDiagEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"An entry in the SFP diagnostic table.
|
||
The index to this table is the same as the ifIndex of the SFP.
|
||
The SFP Diagnostic Table contain and entry for each
|
||
SFP module."
|
||
INDEX { sfpDiagInterface }
|
||
::= { sfpDiagTable 1 }
|
||
|
||
SfpDiagEntry ::=
|
||
SEQUENCE {
|
||
sfpDiagInterface InterfaceIndex,
|
||
|
||
-- Alarms and Warnings Thresholds
|
||
sfpDiagHighTempAlmThreshold INTEGER,
|
||
sfpDiagLowTempAlmThreshold INTEGER,
|
||
sfpDiagHighTempWrnThreshold INTEGER,
|
||
sfpDiagLowTempWrnThreshold INTEGER,
|
||
sfpDiagHighVoltAlmThreshold INTEGER,
|
||
sfpDiagLowVoltAlmThreshold INTEGER,
|
||
sfpDiagHighVoltWrnThreshold INTEGER,
|
||
sfpDiagLowVoltWrnThreshold INTEGER,
|
||
sfpDiagHighTxBiasAlmThreshold INTEGER,
|
||
sfpDiagLowTxBiasAlmThreshold INTEGER,
|
||
sfpDiagHighTxBiasWrnThreshold INTEGER,
|
||
sfpDiagLowTxBiasWrnThreshold INTEGER,
|
||
sfpDiagHighTxPowerAlmThreshold INTEGER,
|
||
sfpDiagLowTxPowerAlmThreshold INTEGER,
|
||
sfpDiagHighTxPowerWrnThreshold INTEGER,
|
||
sfpDiagLowTxPowerWrnThreshold INTEGER,
|
||
sfpDiagHighRxPowerAlmThreshold INTEGER,
|
||
sfpDiagLowRxPowerAlmThreshold INTEGER,
|
||
sfpDiagHighRxPowerWrnThreshold INTEGER,
|
||
sfpDiagLowRxPowerWrnThreshold INTEGER,
|
||
sfpDiagHighLaserTempAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowLaserTempAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighLaserTempWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowLaserTempWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagHighWaveLenAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowWaveLenAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighWaveLenWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowWaveLenWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagHighTecCurrAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagLowTecCurrAlmThreshold INTEGER, -- 15xy
|
||
sfpDiagHighTecCurrWrnThreshold INTEGER, -- 15xy
|
||
sfpDiagLowTecCurrWrnThreshold INTEGER, -- 15xy
|
||
|
||
-- Measured Values
|
||
sfpDiagModuleTemperature INTEGER,
|
||
sfpDiagSupplyVoltage INTEGER,
|
||
sfpDiagTxBias INTEGER,
|
||
sfpDiagTxOutputPower INTEGER,
|
||
sfpDiagRxInputPower INTEGER,
|
||
sfpDiagRxLaserTemperature INTEGER, -- 15xy
|
||
sfpDiagRxMeasuredWavelength INTEGER, -- 15xy
|
||
sfpDiagRxTecCurrent INTEGER, -- 15xy
|
||
|
||
-- Status and Control
|
||
sfpDiagAlarms INTEGER,
|
||
sfpDiagAlarmsMask INTEGER,
|
||
sfpDiagWarnings INTEGER,
|
||
sfpDiagWarningsMask INTEGER,
|
||
sfpDiagConfLowRxPowerAlmThreshold INTEGER,
|
||
sfpDiagRxInputPowerFloat Float32TC,
|
||
|
||
-- CXP
|
||
sfpDiagCxpTxTemp INTEGER,
|
||
sfpDiagCxpHighTxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpLowTxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpRxTemp INTEGER,
|
||
sfpDiagCxpHighRxTempAlmThreshold INTEGER,
|
||
sfpDiagCxpLowRxTempAlmThreshold INTEGER,
|
||
|
||
-- OTDR
|
||
sfpDiagOtdrFiberCutRange INTEGER,
|
||
sfpDiagModuleTemperatureCelsius INTEGER
|
||
}
|
||
|
||
sfpDiagInterface OBJECT-TYPE
|
||
SYNTAX InterfaceIndex
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The Interface Index of the SFP (type=196)."
|
||
::= { sfpDiagEntry 1 }
|
||
-- Alarms and Warnings Thresholds
|
||
|
||
sfpDiagHighTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 2 }
|
||
|
||
sfpDiagLowTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 3 }
|
||
|
||
sfpDiagHighTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 4 }
|
||
|
||
sfpDiagLowTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 5 }
|
||
|
||
sfpDiagHighVoltAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 6 }
|
||
|
||
sfpDiagLowVoltAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 7 }
|
||
|
||
sfpDiagHighVoltWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 8 }
|
||
|
||
sfpDiagLowVoltWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 9 }
|
||
|
||
sfpDiagHighTxBiasAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 10 }
|
||
|
||
sfpDiagLowTxBiasAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage alarm. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 11 }
|
||
|
||
sfpDiagHighTxBiasWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high voltage warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 12 }
|
||
|
||
sfpDiagLowTxBiasWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low voltage warning. The value 0
|
||
means 0 Volts. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 13 }
|
||
|
||
sfpDiagHighTxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high TX power alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 14 }
|
||
|
||
sfpDiagLowTxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low TX power alarm. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 15 }
|
||
|
||
sfpDiagHighTxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high TX power warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 16 }
|
||
|
||
sfpDiagLowTxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low TX power warning. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 65.535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 17 }
|
||
|
||
sfpDiagHighRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high RX power alarm. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 18 }
|
||
|
||
sfpDiagLowRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low RX power alarm. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 19 }
|
||
|
||
sfpDiagHighRxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high RX power warning. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 20 }
|
||
|
||
sfpDiagLowRxPowerWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low RX power warning. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 1 uW,
|
||
yielding a total range of 0 to 6.5535 mW."
|
||
REFERENCE "DWDM MSA Table 2.3.19, SFP-8472 Table 3.15."
|
||
::= { sfpDiagEntry 21 }
|
||
|
||
sfpDiagHighLaserTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write -- 15xy
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 22 }
|
||
|
||
sfpDiagLowLaserTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature alarm. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 23 }
|
||
|
||
sfpDiagHighLaserTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 24 }
|
||
|
||
sfpDiagLowLaserTempWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write -- 15xy
|
||
STATUS current
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature warning. The value 0
|
||
means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 25 }
|
||
|
||
sfpDiagHighWaveLenAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature alarm.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 26 }
|
||
|
||
sfpDiagLowWaveLenAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature alarm.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 27 }
|
||
|
||
sfpDiagHighWaveLenWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for high laser temperature warning.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 28 }
|
||
|
||
sfpDiagLowWaveLenWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The threshold value for low laser temperature warning.
|
||
The reportable wavelength range is 1000.00 <20> 1655.35nm with a resolution
|
||
of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 29 }
|
||
|
||
sfpDiagHighTecCurrAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for high TEC current alarm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 30 }
|
||
|
||
sfpDiagLowTecCurrAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for low TEC current alarm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 31 }
|
||
|
||
sfpDiagHighTecCurrWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for high TEC current warning.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 32 }
|
||
|
||
sfpDiagLowTecCurrWrnThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"The threshold value for low TEC current warning.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7."
|
||
REFERENCE "DWDM MSA Table 2.3.19."
|
||
::= { sfpDiagEntry 33 }
|
||
|
||
-- Diagnostics Measured Values
|
||
|
||
sfpDiagModuleTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured module temperature. The value 0 means -128 Celsuis.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20>3
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 34 }
|
||
|
||
sfpDiagSupplyVoltage OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured supply voltage in transceiver. The value 0 means 0 Volts.
|
||
An increment on one is equivalent to 100 uVolt,
|
||
yielding a total range of +6.55 Volts.
|
||
Accuracy is vendor specific but must be better than <20>3% of the
|
||
manufacturer<65>s nominal value over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 35 }
|
||
|
||
sfpDiagTxBias OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured TX Bias Current. The value 0
|
||
means 0 Volt. An increment on one is equivalent to 2 uA,
|
||
yielding a total range of 0 to 131 mA.
|
||
Accuracy is vendor specific but must be better than <20>3dB over specified
|
||
temperature and voltage. Data is not valid when the transmitter is disabled."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 36 }
|
||
|
||
sfpDiagTxOutputPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured TX output power. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW.
|
||
For the vendor specified wavelength, accuracy shall be better than <20>3dB
|
||
over specified temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 37 }
|
||
|
||
sfpDiagRxInputPower OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured RX input power. The value 0
|
||
means 0 Watts. An increment on one is equivalent to 0.1 uW,
|
||
yielding a total range of 0 to 6.5535 mW.
|
||
For the vendor specified wavelength, accuracy shall be better than <20>3dB
|
||
over specified temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 38 }
|
||
|
||
sfpDiagRxLaserTemperature OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Temperature.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent
|
||
to 1/256 degree, yielding a total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20> 0.2
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 39 }
|
||
|
||
sfpDiagRxMeasuredWavelength OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Wavelength.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The wavelength is defined as:
|
||
Wavelength = 1000nm + 0.01nm * 16 bit value.
|
||
Thus, the reportable wavelength range is 1000.00 <20> 1655.35nm with a
|
||
resolution of 0.01nm."
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 40 }
|
||
|
||
sfpDiagRxTecCurrent OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current -- 15xy
|
||
DESCRIPTION
|
||
"Measured Laser Temperature or Wavelength.
|
||
For DWDM applications, the diagnostic interface report either laser
|
||
wavelength or temperature, with a given module<6C>s reporting defined
|
||
by bit 1 of the object sfpConfigOptionalWdm.
|
||
The reported TEC current is defined as a positive number for cooling and
|
||
a negative number for heating starting at -3276.8.
|
||
The increments are of 0.1 steps yielding a total range of -3276.8 to +3276.7,
|
||
The accuracy of the TEC current monitor is vendor specific but must be
|
||
better than <20>15% of the maximum TEC current as stored in the TEC Current
|
||
High Alarm Threshold"
|
||
REFERENCE "DWDM MSA Table 2.3.21."
|
||
::= { sfpDiagEntry 41 }
|
||
|
||
-- Status and Control
|
||
|
||
sfpDiagAlarms OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Alarms of the SFP module.
|
||
The sfpDiagAlarms is a bit map represented as a sum, therefore,
|
||
it can represent multiple failures (alarms) simultaneously.
|
||
The various bit positions are:
|
||
0 Temp High Alarm Set when internal temperature exceeds high alarm level.
|
||
1 Temp Low Alarm Set when internal temperature is below low alarm level.
|
||
2 Vcc High Alarm Set when internal supply voltage exceeds high alarm level.
|
||
3 Vcc Low Alarm Set when internal supply voltage is below low alarm level.
|
||
4 TX Bias High Alarm Set when TX Bias current exceeds high alarm level.
|
||
5 TX Bias Low Alarm Set when TX Bias current is below low alarm level.
|
||
6 TX Power High Alarm Set when TX output power exceeds high alarm level.
|
||
7 TX Power Low Alarm Set when TX output power is below low alarm level.
|
||
8 RX Power High Alarm Set when Received Power exceeds high alarm level.
|
||
9 RX Power Low Alarm Set when Received Power is below low alarm level.
|
||
10 (15xy) Laser T/W High Alarm Set when laser temperature or wavelength exceeds high alarm level.
|
||
11 (15xy) Laser T/W Low Alarm Set when laser temperature or wavelength is below low alarm level.
|
||
12 (15xy) TEC Current High Alarm Set when TEC current exceeds high alarm level.
|
||
13 (15xy) TEC Current Low Alarm Set when TEC current is below low alarm level.
|
||
14 Retimer Loss Of Lock
|
||
15 Removed SFP
|
||
16 Rx Signal Detect alarm
|
||
17 Laser End of Life
|
||
18 Laser Tx Failure Indication."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 42 }
|
||
|
||
sfpDiagAlarmsMask OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Masking of the Alarms of the SFP module.
|
||
The sfpDiagAlarmsMask is a bit map. Any of the alarm and warning flags can
|
||
be masked by writing a 1 to the corresponding bits.
|
||
The various bit positions are:
|
||
0 Temp High Wanring Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Wanring Set when internal temperature is below low warning level.
|
||
2 Vcc High Wanring Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Wanring Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Wanring Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Wanring Set when TX Bias current is below low warning level.
|
||
6 TX Power High Wanring Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Wanring Set when TX output power is below low warning level.
|
||
8 RX Power High Wanring Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Wanring Set when Received Power is below low warning level.
|
||
10 (15xy) Laser T/W High Wanring Set when laser temperature or wavelength exceeds high warning level.
|
||
11 (15xy) Laser T/W Low Wanring Set when laser temperature or wavelength is below low warning level.
|
||
12 (15xy) TEC Current High Wanring Set when TEC current exceeds high warning level.
|
||
13 (15xy) TEC Current Low Wanring Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 43 }
|
||
|
||
sfpDiagWarnings OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Warnings of the SFP module.
|
||
The sfpDiagWarnings is a bit map represented as a sum, therefore,
|
||
it can represent multiple failures (alarms) simultaneously.
|
||
The various bit positions are:
|
||
0 Temp High Warning Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Warning Set when internal temperature is below low warning level.
|
||
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
|
||
6 TX Power High Warning Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Warning Set when TX output power is below low warning level.
|
||
8 RX Power High Warning Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Warning Set when Received Power is below low warning level.
|
||
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
|
||
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
|
||
12 TEC Current High Warning Set when TEC current exceeds high warning level.
|
||
13 TEC Current Low Warning Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 44 }
|
||
|
||
sfpDiagWarningsMask OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"This object indicates the Masking of the Warnings of the SFP module.
|
||
The sfpDiagWarningsMask is a bit map. Any of the alarm and warning flags can
|
||
be masked by writing a 1 to the corresponding bits.
|
||
The various bit positions are:
|
||
0 Temp High Warning Set when internal temperature exceeds high warning level.
|
||
1 Temp Low Warning Set when internal temperature is below low warning level.
|
||
2 Vcc High Warning Set when internal supply voltage exceeds high warning level.
|
||
3 Vcc Low Warning Set when internal supply voltage is below low warning level.
|
||
4 TX Bias High Warning Set when TX Bias current exceeds high warning level.
|
||
5 TX Bias Low Warning Set when TX Bias current is below low warning level.
|
||
6 TX Power High Warning Set when TX output power exceeds high warning level.
|
||
7 TX Power Low Warning Set when TX output power is below low warning level.
|
||
8 RX Power High Warning Set when Received Power exceeds high warning level.
|
||
9 RX Power Low Warning Set when Received Power is below low warning level.
|
||
10 Laser T/W High Warning Set when laser temperature or wavelength exceeds high warning level.
|
||
11 Laser T/W Low Warning Set when laser temperature or wavelength is below low warning level.
|
||
12 TEC Current High Warning Set when TEC current exceeds high warning level.
|
||
13 TEC Current Low Warning Set when TEC current is below low warning level."
|
||
REFERENCE "DWDM MSA Table 2.3.22, SFP-8472 Table 3.18."
|
||
::= { sfpDiagEntry 45 }
|
||
|
||
sfpDiagConfLowRxPowerAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Configured threshold value for low RX power alarm.
|
||
Changing this value doen't affect the SFP and is implemented by software.
|
||
The threshold level specified in 0.1 dBm units.
|
||
The range starts with -50.0 dBm."
|
||
::= { sfpDiagEntry 46 }
|
||
|
||
sfpDiagRxInputPowerFloat OBJECT-TYPE
|
||
SYNTAX Float32TC
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Measured RX input power sepcified in floating units.
|
||
This object is used for power < -40dBm that can be achieved with SFP external calibration.
|
||
When not used this value is 0 and sfpDiagRxInputPower should be used."
|
||
::= { sfpDiagEntry 47 }
|
||
|
||
--
|
||
-- CXP
|
||
--
|
||
|
||
sfpDiagCxpTxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured Tx temperature. The value 0 means -128 Celsius.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 22-23 (Tx Lower Page)"
|
||
::= { sfpDiagEntry 50 }
|
||
|
||
sfpDiagCxpHighTxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high Tx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 128-129 (Tx Upper Page)"
|
||
::= { sfpDiagEntry 51 }
|
||
|
||
sfpDiagCxpLowTxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low Tx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 130-131 (Tx Upper Page)"
|
||
::= { sfpDiagEntry 52 }
|
||
|
||
sfpDiagCxpRxTemp OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured Rx temperature. The value 0 means -128 Celsius.
|
||
An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 22-23 (Rx Lower Page)"
|
||
::= { sfpDiagEntry 53 }
|
||
|
||
sfpDiagCxpHighRxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for high Rx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 128-129 (Rx Upper Page)"
|
||
::= { sfpDiagEntry 54 }
|
||
|
||
sfpDiagCxpLowRxTempAlmThreshold OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The threshold value for low Rx temperature alarm.
|
||
The value 0 means -128 Celsuis. An increment on one is equivalent to 1/256 degree,
|
||
yielding a total range of -128 to +128 Celsius
|
||
For CXP Addr 130-131 (Rx Upper Page)"
|
||
::= { sfpDiagEntry 55 }
|
||
|
||
sfpDiagOtdrFiberCutRange OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"The OTDR calculated range to the fiber cut"
|
||
::= { sfpDiagEntry 56 }
|
||
|
||
sfpDiagModuleTemperatureCelsius OBJECT-TYPE
|
||
SYNTAX INTEGER
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Internally measured module temperature, while degress in Celsuis.
|
||
Total range of -128 to +128 Celsius.
|
||
Temperature accuracy is vendor specific but must be better than <20>3
|
||
degrees Celsius over specified operating temperature and voltage."
|
||
REFERENCE "DWDM MSA Table 2.3.21, SFP-8472 Table 3.17."
|
||
::= { sfpDiagEntry 57 }
|
||
|
||
-- ----------------------------------------------------
|
||
--
|
||
-- The SFP Traps
|
||
--
|
||
-- ----------------------------------------------------
|
||
|
||
sfpConfigChangeTrap NOTIFICATION-TYPE
|
||
OBJECTS { sfpConfigInterface }
|
||
STATUS current
|
||
DESCRIPTION
|
||
"A sfpTrapsChangeTrap trap is sent when the
|
||
content of an instance sfpConfigEntry changes. It
|
||
can be utilized by an NMS to trigger polls."
|
||
::= { sfpTraps 1 }
|
||
|
||
END
|