towerops/priv/mibs/packetlight/SL-SECU-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

304 lines
7.9 KiB
Text

SL-SECU-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32, transmission, IpAddress
FROM SNMPv2-SMI
InterfaceIndex FROM IF-MIB
DisplayString, TruthValue, RowStatus, DateAndTime
FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
slMain FROM SL-MAIN-MIB;
-- This is the MIB module for PL security.
slSecuMib MODULE-IDENTITY
LAST-UPDATED "201105170000Z"
ORGANIZATION "PacketLight Networks Ltd."
CONTACT-INFO
"Omri_Viner@PacketLight.com"
DESCRIPTION
"This security module. This mib is used to configure the firewall."
::= { slMain 24 }
SlSecuType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The security protocol types:
Telnet - CLI
SSH - Secured Telnet
HTTP - Hyper Text
HTTPS - Secured HTTP
ICMP - Ping
SNMP - Simple Network Management (only 161 is supported)
FTP - File Transfer
TFTP - Trivial FTP
TL1 - TL1 over Telnet
TL1SSH - TL1 over SSH
WL - White list (port number is 0)
SNMPOVERTCP - SNMP over TCP
SFTP - Client side"
SYNTAX INTEGER {
telnet(1),
ssh(2),
http(3),
https(4),
icmp(5),
snmp(6),
ftp(7),
tftp(8),
tl1(9),
tl1ssh(10),
wl(11),
snmpovertcp(12),
sftp(13)
}
slSecuGen OBJECT IDENTIFIER ::= { slSecuMib 1 }
slSecuSelect OBJECT IDENTIFIER ::= { slSecuMib 2 }
slSecuWl OBJECT IDENTIFIER ::= { slSecuMib 3 }
slSecuEncryption OBJECT IDENTIFIER ::= { slSecuMib 4 }
-- The Security general part
slSecuFirewallEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"General Enable/Disable of the firewall operation."
::= { slSecuGen 1 }
-- The Security Selection Table
slSecuSelectTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSecuSelectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The security protocol selection table."
::= { slSecuSelect 1 }
slSecuSelectEntry OBJECT-TYPE
SYNTAX SlSecuSelectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the security selection table."
INDEX { slSecuSelectType }
::= { slSecuSelectTable 1 }
SlSecuSelectEntry ::=
SEQUENCE {
slSecuSelectType SlSecuType,
slSecuSelectPort INTEGER,
slSecuSelectEnable TruthValue
}
slSecuSelectType OBJECT-TYPE
SYNTAX SlSecuType
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The secutity protocol type"
::= { slSecuSelectEntry 1 }
slSecuSelectPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The corresponding port number of the protocol.
Port number 0 is used when not applicable/available."
::= { slSecuSelectEntry 2 }
slSecuSelectEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"True - Enables the firewall for the corresponding protocol.
False - Dsables the firewall for the corresponding protocol.
When enabled the firewall blocks the protocol."
::= { slSecuSelectEntry 3 }
-- IP White List Table
-- The IP white list Table odefine which IP addresses are allowed.
slSecuWlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSecuWlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This white list table."
::= { slSecuWl 1 }
slSecuWlEntry OBJECT-TYPE
SYNTAX SlSecuWlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A particular IP address."
INDEX { slSecuWlIp }
::= { slSecuWlTable 1 }
SlSecuWlEntry ::=
SEQUENCE {
slSecuWlIp
IpAddress,
slSecuWlMask
IpAddress,
slSecuWlStatus
RowStatus
}
slSecuWlIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to allow"
::= { slSecuWlEntry 1 }
slSecuWlMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the mask to be logical-ANDed with the
destination address before being compared to
the value in the slSecuWlIp field."
::= { slSecuWlEntry 2 }
slSecuWlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The row status variable, used according to
row installation and removal conventions."
::= { slSecuWlEntry 3 }
-- *******************************************
--
-- The Encryption Table
--
-- *******************************************
slSecuEncryptionTable OBJECT-TYPE
SYNTAX SEQUENCE OF SlSecuEncryptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The encryption table. This table has an entry per transponder."
::= { slSecuEncryption 1 }
slSecuEncryptionEntry OBJECT-TYPE
SYNTAX SlSecuEncryptionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry is used to control the necryption per transponder."
INDEX { slSecuEncryptionIfIndex }
::= { slSecuEncryptionTable 1 }
SlSecuEncryptionEntry ::=
SEQUENCE {
slSecuEncryptionIfIndex InterfaceIndex,
slSecuEncryptionEnable TruthValue,
slSecuEncryptionStatus INTEGER,
slSecuEncryptionForceInit INTEGER,
slSecuEncryptionPreShared DisplayString,
slSecuEncryptionKeyExchangePeriod INTEGER,
slSecuEncryptionLock TruthValue,
slSecuEncryptionProtectedStatus INTEGER
}
slSecuEncryptionIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interface Index of the uplink port."
::= { slSecuEncryptionEntry 1 }
slSecuEncryptionEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the encryption on this uplink."
::= { slSecuEncryptionEntry 2 }
slSecuEncryptionStatus OBJECT-TYPE
SYNTAX INTEGER {
init(1), --- init/link-failure state
exchange(2), --- public key exchange state
kdf(3), --- key derivation function state
active(4) --- active state
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of the encryption finite state machine."
::= { slSecuEncryptionEntry 3 }
slSecuEncryptionForceInit OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing this valiable forces init to the encryption state machine."
::= { slSecuEncryptionEntry 4 }
slSecuEncryptionPreShared OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The pre-shared secret.
Either the pre-shared key, or the shared secret to avoid Mitm when using DH public key exchange."
::= { slSecuEncryptionEntry 5 }
slSecuEncryptionKeyExchangePeriod OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Key Exchage Period, specified in minutes.
The value 0 means to perform the key exchange only once at link establishment."
::= { slSecuEncryptionEntry 6 }
slSecuEncryptionLock OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Lock/Unlock the encrypted service for this uplink."
::= { slSecuEncryptionEntry 7 }
slSecuEncryptionProtectedStatus OBJECT-TYPE
SYNTAX INTEGER {
init(1), --- init/link-failure state
exchange(2), --- public key exchange state
kdf(3), --- key derivation function state
active(4) --- active state
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The protected port state of the encryption finite state machine."
::= { slSecuEncryptionEntry 8 }
END