- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
84 lines
3.1 KiB
Text
84 lines
3.1 KiB
Text
-- *****************************************************************
|
|
-- PacketLight SiteLight Network Element MIB
|
|
--
|
|
-- Nov 2000, Omri Viner
|
|
--
|
|
-- Copyright (c) 1999-2000 by PacketLight Ltd.
|
|
-- All rights reserved.
|
|
-- *****************************************************************
|
|
|
|
SL-NE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
enterprises, NOTIFICATION-TYPE FROM SNMPv2-SMI
|
|
DisplayString, TruthValue FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
InterfaceIndex FROM IF-MIB;
|
|
|
|
|
|
packetlight MODULE-IDENTITY
|
|
LAST-UPDATED "200009260000Z"
|
|
ORGANIZATION "PacketLight Networks Ltd."
|
|
CONTACT-INFO
|
|
"Omri_Viner@PacketLight.com"
|
|
DESCRIPTION
|
|
"The MIB module is the root of the PL extension mibs."
|
|
::= { enterprises 4515 }
|
|
|
|
sitelight OBJECT IDENTIFIER ::= { packetlight 1 }
|
|
plproduct OBJECT IDENTIFIER ::= { packetlight 100 }
|
|
|
|
-- Values for the sysObjectId
|
|
|
|
plne OBJECT IDENTIFIER ::= { plproduct 1 }
|
|
|
|
pl10 OBJECT IDENTIFIER ::= { plne 10 } -- pl-10
|
|
pl10H OBJECT IDENTIFIER ::= { pl10 1 } -- pl-10 half box
|
|
pl10F OBJECT IDENTIFIER ::= { pl10 2 } -- pl-10 full box
|
|
|
|
pl20 OBJECT IDENTIFIER ::= { plne 20 } -- pl-20
|
|
pl20H OBJECT IDENTIFIER ::= { pl20 1 } -- pl-20 half box
|
|
pl20F OBJECT IDENTIFIER ::= { pl20 2 } -- pl-20 full box
|
|
|
|
pl100 OBJECT IDENTIFIER ::= { plne 100 } -- pl-100
|
|
pl100E OBJECT IDENTIFIER ::= { pl100 1 } -- pl-100 12 x ESCON
|
|
pl100F OBJECT IDENTIFIER ::= { pl100 2 } -- pl-100 4 x FC
|
|
pl100FG OBJECT IDENTIFIER ::= { pl100 3 } -- pl-100 4 x FC or GBE
|
|
pl100EF OBJECT IDENTIFIER ::= { pl100 4 } -- pl-100 4 x FC and 8 x ESCON
|
|
pl100EFG OBJECT IDENTIFIER ::= { pl100 5 } -- pl-100 4 x FC or GBE, and 8 x ESCON
|
|
pl100FT OBJECT IDENTIFIER ::= { pl100 12 } -- pl-100 4 x FC - GFP-T
|
|
|
|
plopto OBJECT IDENTIFIER ::= { plne 150 } -- pl-opto
|
|
ploptoXB OBJECT IDENTIFIER ::= { plopto 1 } -- pl-opto booster 4 x XPDR and 1 x EDFA
|
|
ploptoI OBJECT IDENTIFIER ::= { plopto 2 } -- pl-opto inline 2 x EDFA
|
|
ploptoX OBJECT IDENTIFIER ::= { plopto 3 } -- pl-opto transponder 4 x XPDR
|
|
|
|
pl200 OBJECT IDENTIFIER ::= { plne 200 } -- pl-200
|
|
|
|
pl400r OBJECT IDENTIFIER ::= { plne 400 } -- pl-400 Root
|
|
pl400 OBJECT IDENTIFIER ::= { pl400r 1 } -- pl-400
|
|
|
|
pl404r OBJECT IDENTIFIER ::= { plne 404 } -- pl-400E Root
|
|
pl400e OBJECT IDENTIFIER ::= { pl404r 1 } -- pl-400E
|
|
|
|
pl408r OBJECT IDENTIFIER ::= { plne 408 } -- pl-400X Root
|
|
pl400x OBJECT IDENTIFIER ::= { pl408r 1 } -- pl-400X
|
|
|
|
pl1000r OBJECT IDENTIFIER ::= { plne 1000 } -- pl-1000 Root
|
|
pl1000 OBJECT IDENTIFIER ::= { pl1000r 1 } -- pl-1000
|
|
pl1000e OBJECT IDENTIFIER ::= { pl1000r 2 } -- pl-1000E (former PL-800)
|
|
pl1000em OBJECT IDENTIFIER ::= { pl1000r 3 } -- pl-1000EM
|
|
pl1000ro OBJECT IDENTIFIER ::= { pl1000r 4 } -- pl-1000RO
|
|
pl1000tn OBJECT IDENTIFIER ::= { pl1000r 5 } -- pl-1000TN
|
|
|
|
pl2000r OBJECT IDENTIFIER ::= { plne 2000 } -- pl-2000 Root
|
|
pl2000 OBJECT IDENTIFIER ::= { pl2000r 1 } -- pl-2000
|
|
|
|
|
|
-- The root for the service mibs
|
|
|
|
slService OBJECT IDENTIFIER ::= { sitelight 1 }
|
|
|
|
END
|