- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
102 lines
3 KiB
Text
102 lines
3 KiB
Text
LINKSYS-STACK-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: LINKSYS LOCALIZATION ROS
|
|
-- This Private MIB supports the unit id configuration for stack of ROS products
|
|
-- Version: 7.40
|
|
-- Date: 21 Nov 2005
|
|
--
|
|
-- 01-Nov-2005 Add rlStackUnitMacAddressAfterReset
|
|
-- 21-Nov-2005 Change range of rlStackActiveUnitIdAfterReset
|
|
|
|
IMPORTS
|
|
MacAddress FROM BRIDGE-MIB
|
|
rnd FROM LINKSYS-MIB OBJECT-TYPE,
|
|
MODULE-IDENTITY FROM SNMPv2-SMI
|
|
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
|
|
|
|
|
rlStack MODULE-IDENTITY
|
|
LAST-UPDATED "200504140000Z"
|
|
ORGANIZATION "Linksys LLC."
|
|
CONTACT-INFO
|
|
"www.linksys.com/business/support"
|
|
DESCRIPTION
|
|
"The private MIB module definition for stack."
|
|
REVISION "200504140000Z"
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { rnd 107 }
|
|
|
|
rlStackActiveUnitIdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlStackActiveUnitIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing the active unit id of the requested unit."
|
|
::= {rlStack 1 }
|
|
|
|
rlStackActiveUnitIdEntry OBJECT-TYPE
|
|
SYNTAX RlStackActiveUnitIdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlStackActiveUnitIdTable."
|
|
INDEX {rlStackCurrentUnitId }
|
|
::= {rlStackActiveUnitIdTable 1 }
|
|
|
|
RlStackActiveUnitIdEntry ::= SEQUENCE {
|
|
rlStackCurrentUnitId INTEGER,
|
|
rlStackActiveUnitIdAfterReset INTEGER
|
|
}
|
|
|
|
rlStackCurrentUnitId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit number device, which is the active unit id"
|
|
::= {rlStackActiveUnitIdEntry 1 }
|
|
|
|
|
|
rlStackActiveUnitIdAfterReset OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the unit id that will be after reset."
|
|
::= {rlStackActiveUnitIdEntry 2 }
|
|
|
|
rlStackUnitModeAfterReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone(1),
|
|
stack(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set unit type that will be after reset, standalone or stack."
|
|
::= {rlStack 2 }
|
|
|
|
rlStackUnitMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
standalone(1),
|
|
stack(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"show unit type standalone or stack."
|
|
::= {rlStack 3 }
|
|
|
|
rlStackUnitMacAddressAfterReset OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MAC address used by this bridge after rest."
|
|
REFERENCE
|
|
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
|
|
::= { rlStack 4 }
|
|
|
|
END
|
|
|