towerops/priv/mibs/linksys/LINKSYS-STACK-MIB
Graham McIntire b4f8b40b7f
Include MIB files in Docker image instead of using PVC
- Remove PVC volume mount from k8s/deployment.yaml
- Delete k8s/mib-pvc.yaml (no longer needed)
- Update .gitignore to commit MIB files to git
- Add mix import_mibs task to copy MIBs from LibreNMS
- Add all MIB files from priv/mibs/ to git

This fixes the multi-attach volume error in Kubernetes where new pods
couldn't start because the RWO (ReadWriteOnce) PVC was attached to the
old pod. MIBs are now part of the Docker image and can be used by all
pods simultaneously.
2026-01-19 14:01:03 -06:00

102 lines
3 KiB
Text

LINKSYS-STACK-MIB DEFINITIONS ::= BEGIN
-- Title: LINKSYS LOCALIZATION ROS
-- This Private MIB supports the unit id configuration for stack of ROS products
-- Version: 7.40
-- Date: 21 Nov 2005
--
-- 01-Nov-2005 Add rlStackUnitMacAddressAfterReset
-- 21-Nov-2005 Change range of rlStackActiveUnitIdAfterReset
IMPORTS
MacAddress FROM BRIDGE-MIB
rnd FROM LINKSYS-MIB OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
TruthValue, TEXTUAL-CONVENTION FROM SNMPv2-TC;
rlStack MODULE-IDENTITY
LAST-UPDATED "200504140000Z"
ORGANIZATION "Linksys LLC."
CONTACT-INFO
"www.linksys.com/business/support"
DESCRIPTION
"The private MIB module definition for stack."
REVISION "200504140000Z"
DESCRIPTION
"Initial revision."
::= { rnd 107 }
rlStackActiveUnitIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" The table listing the active unit id of the requested unit."
::= {rlStack 1 }
rlStackActiveUnitIdEntry OBJECT-TYPE
SYNTAX RlStackActiveUnitIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the rlStackActiveUnitIdTable."
INDEX {rlStackCurrentUnitId }
::= {rlStackActiveUnitIdTable 1 }
RlStackActiveUnitIdEntry ::= SEQUENCE {
rlStackCurrentUnitId INTEGER,
rlStackActiveUnitIdAfterReset INTEGER
}
rlStackCurrentUnitId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit number device, which is the active unit id"
::= {rlStackActiveUnitIdEntry 1 }
rlStackActiveUnitIdAfterReset OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the unit id that will be after reset."
::= {rlStackActiveUnitIdEntry 2 }
rlStackUnitModeAfterReset OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"set unit type that will be after reset, standalone or stack."
::= {rlStack 2 }
rlStackUnitMode OBJECT-TYPE
SYNTAX INTEGER {
standalone(1),
stack(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"show unit type standalone or stack."
::= {rlStack 3 }
rlStackUnitMacAddressAfterReset OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAC address used by this bridge after rest."
REFERENCE
"IEEE 802.1D-1990: Sections 6.4.1.1.3 and 3.12.5"
::= { rlStack 4 }
END