- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
6261 lines
197 KiB
Text
6261 lines
197 KiB
Text
OPT-IF-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Integer32,
|
|
Unsigned32, transmission
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, RowPointer, RowStatus, TruthValue
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
ifIndex
|
|
FROM IF-MIB;
|
|
|
|
-- This is the MIB module for the OTN Interface objects.
|
|
|
|
optIfMibModule MODULE-IDENTITY
|
|
LAST-UPDATED "200308130000Z"
|
|
ORGANIZATION "IETF AToM MIB Working Group"
|
|
CONTACT-INFO
|
|
"WG charter:
|
|
http://www.ietf.org/html.charters/atommib-charter.html
|
|
|
|
Mailing Lists:
|
|
General Discussion: atommib@research.telcordia.com
|
|
To Subscribe: atommib-request@research.telcordia.com
|
|
Editor: Hing-Kam Lam
|
|
Postal: Lucent Technologies, Room 4C-616
|
|
101 Crawfords Corner Road
|
|
Holmdel, NJ 07733
|
|
Tel: +1 732 949 8338
|
|
Email: hklam@lucent.com"
|
|
DESCRIPTION
|
|
"The MIB module to describe pre-OTN and OTN interfaces.
|
|
|
|
Copyright (C) The Internet Society (2003). This version
|
|
of this MIB module is part of RFC 3591; see the RFC
|
|
itself for full legal notices."
|
|
REVISION "200308130000Z"
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 3591."
|
|
::={ transmission 133 }
|
|
|
|
-- textual conventions
|
|
|
|
OptIfAcTI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier (TI) accepted at the receiver."
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
|
|
OptIfBitRateK ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the index 'k' that is used to
|
|
represent a supported bit rate and the different
|
|
versions of OPUk, ODUk and OTUk.
|
|
Allowed values of k are defined in ITU-T G.709.
|
|
Currently allowed values in G.709 are:
|
|
k=1 represents an approximate bit rate of 2.5 Gbit/s,
|
|
k=2 represents an approximate bit rate of 10 Gbit/s,
|
|
k=3 represents an approximate bit rate of 40 Gbit/s."
|
|
SYNTAX Integer32
|
|
|
|
OptIfDEGM ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if OptIfDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
SYNTAX Unsigned32 (2..10)
|
|
|
|
OptIfDEGThr ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to OptIfDEGThr."
|
|
SYNTAX Unsigned32 (1..100)
|
|
|
|
OptIfDirectionality ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of an entity."
|
|
SYNTAX INTEGER {
|
|
sink(1),
|
|
source(2),
|
|
bidirectional(3)
|
|
}
|
|
|
|
OptIfSinkOrSource ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of an entity
|
|
that is allowed only to be a source or sink."
|
|
SYNTAX INTEGER {
|
|
sink(1),
|
|
source(2)
|
|
}
|
|
|
|
OptIfExDAPI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Destination Access Point Identifier (DAPI)
|
|
expected by the receiver."
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
|
|
OptIfExSAPI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Source Access Point Identifier (SAPI)
|
|
expected by the receiver."
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
|
|
OptIfIntervalNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a 15-minute interval. The interval
|
|
identified by 1 is the most recently completed interval, and
|
|
the interval identified by n is the interval immediately
|
|
preceding the one identified by n-1."
|
|
SYNTAX Unsigned32 (1..96)
|
|
|
|
OptIfTIMDetMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
dapi(2),
|
|
sapi(3),
|
|
both(4)
|
|
}
|
|
|
|
OptIfTxTI ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier (TI) transmitted."
|
|
SYNTAX OCTET STRING (SIZE(64))
|
|
|
|
-- object groups
|
|
|
|
optIfObjects OBJECT IDENTIFIER ::= { optIfMibModule 1 }
|
|
optIfConfs OBJECT IDENTIFIER ::= { optIfMibModule 2 }
|
|
|
|
optIfOTMn OBJECT IDENTIFIER ::= { optIfObjects 1 }
|
|
optIfPerfMon OBJECT IDENTIFIER ::= { optIfObjects 2 }
|
|
optIfOTSn OBJECT IDENTIFIER ::= { optIfObjects 3 }
|
|
optIfOMSn OBJECT IDENTIFIER ::= { optIfObjects 4 }
|
|
optIfOChGroup OBJECT IDENTIFIER ::= { optIfObjects 5 }
|
|
optIfOCh OBJECT IDENTIFIER ::= { optIfObjects 6 }
|
|
|
|
optIfOTUk OBJECT IDENTIFIER ::= { optIfObjects 7 }
|
|
optIfODUk OBJECT IDENTIFIER ::= { optIfObjects 8 }
|
|
optIfODUkT OBJECT IDENTIFIER ::= { optIfObjects 9 }
|
|
|
|
optIfGroups OBJECT IDENTIFIER ::= { optIfConfs 1 }
|
|
optIfCompl OBJECT IDENTIFIER ::= { optIfConfs 2 }
|
|
|
|
-- the optIfOTMn group
|
|
-- This group defines the OTM structure information of an
|
|
-- optical interface.
|
|
|
|
-- OTMn Table
|
|
|
|
optIfOTMnTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTMnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTMn structure information."
|
|
::= { optIfOTMn 1 }
|
|
|
|
optIfOTMnEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTMnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains the OTMn structure
|
|
information of an optical interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTMnTable 1 }
|
|
|
|
OptIfOTMnEntry ::=
|
|
SEQUENCE {
|
|
optIfOTMnOrder Unsigned32,
|
|
optIfOTMnReduced TruthValue,
|
|
optIfOTMnBitRates BITS,
|
|
optIfOTMnInterfaceType SnmpAdminString,
|
|
optIfOTMnTcmMax Unsigned32,
|
|
optIfOTMnOpticalReach INTEGER
|
|
}
|
|
|
|
optIfOTMnOrder OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..900)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the order of the OTM, which
|
|
represents the maximum number of wavelengths that can be
|
|
supported at the bit rate(s) supported on the interface."
|
|
::= { optIfOTMnEntry 1 }
|
|
|
|
optIfOTMnReduced OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether a reduced or full
|
|
functionality is supported at the interface. A value of
|
|
true means reduced. A value of false means full."
|
|
::= { optIfOTMnEntry 2 }
|
|
|
|
optIfOTMnBitRates OBJECT-TYPE
|
|
SYNTAX BITS { bitRateK1(0), bitRateK2(1), bitRateK3(2) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is a bit map representing the bit
|
|
rate or set of bit rates supported on the interface.
|
|
The meaning of each bit position is as follows:
|
|
bitRateK1(0) is set if the 2.5 Gbit/s rate is supported
|
|
bitRateK2(1) is set if the 10 Gbit/s rate is supported
|
|
bitRateK3(2) is set if the 40 Gbit/s rate is supported
|
|
Note that each bit position corresponds to one possible
|
|
value of the type OptIfBitRateK.
|
|
The default value of this attribute is system specific."
|
|
::= { optIfOTMnEntry 3 }
|
|
|
|
optIfOTMnInterfaceType OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the type of interface. The value of
|
|
this attribute will affect the behavior of the OTM with
|
|
respect to presence/absence of OTM Overhead Signal (OOS)
|
|
processing and TCM activation. For an IrDI interface,
|
|
there is no OOS processing and TCM activation is limited
|
|
to n levels as specified by a TCM level threshold.
|
|
|
|
This object contains two fields that are separated by
|
|
whitespace. The possible values are:
|
|
field 1: one of the 4-character ASCII strings
|
|
'IrDI' or 'IaDI'
|
|
field 2: free-form text consisting of printable
|
|
UTF-8 encoded characters
|
|
|
|
Note that field 2 is optional. If it is not present then there
|
|
is no requirement for trailing whitespace after field 1.
|
|
|
|
The default values are as follows:
|
|
field 1: 'IaDI'
|
|
field 2: an empty string."
|
|
|
|
::= { optIfOTMnEntry 4 }
|
|
|
|
optIfOTMnTcmMax OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..6)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object identifies the maximum number of TCM
|
|
levels allowed for any Optical Channel contained
|
|
in this OTM. A new TCM activation will be rejected
|
|
if the requested level is greater than the threshold.
|
|
If InterfaceType object specifies a type of 'IaDI'
|
|
for this OTM, then this attribute is irrelevant.
|
|
|
|
Possible values: unsigned integers in the range
|
|
from 0 to 6 inclusive.
|
|
Default value: 3."
|
|
|
|
::= { optIfOTMnEntry 5 }
|
|
|
|
optIfOTMnOpticalReach OBJECT-TYPE
|
|
SYNTAX INTEGER { intraOffice(1), shortHaul(2), longHaul(3),
|
|
veryLongHaul(4), ultraLongHaul(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the length the optical signal
|
|
may travel before requiring termination or regeneration.
|
|
The meaning of the enumeration are:
|
|
intraOffice(1) - intra-office (as defined in ITU-T G.957)
|
|
shortHaul(2) - short haul (as defined in ITU-T G.957)
|
|
longHaul(3) - long haul (as defined in ITU-T G.957)
|
|
veryLongHaul(4) - very long haul (as defined in ITU-T G.691)
|
|
ultraLongHaul(5)- ultra long haul (as defined in ITU-T G.691)"
|
|
::= { optIfOTMnEntry 6 }
|
|
|
|
-- the optIfPerfMon group
|
|
-- This group defines performance monitoring objects for all
|
|
-- layers.
|
|
|
|
-- PM interval table
|
|
|
|
optIfPerfMonIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfPerfMonIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of 15-minute performance monitoring interval
|
|
information."
|
|
::= { optIfPerfMon 1 }
|
|
|
|
optIfPerfMonIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfPerfMonIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A conceptual row that contains 15-minute performance
|
|
monitoring interval information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfPerfMonIntervalTable 1 }
|
|
|
|
OptIfPerfMonIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfPerfMonCurrentTimeElapsed Gauge32,
|
|
optIfPerfMonCurDayTimeElapsed Gauge32,
|
|
optIfPerfMonIntervalNumIntervals Unsigned32,
|
|
optIfPerfMonIntervalNumInvalidIntervals Unsigned32
|
|
}
|
|
|
|
optIfPerfMonCurrentTimeElapsed OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..900)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds elapsed in the current 15-minute
|
|
performance monitoring interval.
|
|
If, for some reason, such as an adjustment in the NE's
|
|
time-of-day clock, the number of seconds elapsed exceeds
|
|
the maximum value, then the maximum value will be returned."
|
|
::= { optIfPerfMonIntervalEntry 1 }
|
|
|
|
optIfPerfMonCurDayTimeElapsed OBJECT-TYPE
|
|
SYNTAX Gauge32 (0..86400)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of seconds elapsed in the current 24-hour interval
|
|
performance monitoring period.
|
|
If, for some reason, such as an adjustment in the NE's
|
|
time-of-day clock, the number of seconds elapsed exceeds
|
|
the maximum value, then the maximum value will be returned."
|
|
::= { optIfPerfMonIntervalEntry 2 }
|
|
|
|
optIfPerfMonIntervalNumIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of 15-minute intervals for which performance
|
|
monitoring data is available. The number is the same for all
|
|
the associated sub layers of the interface.
|
|
An optical interface must be capable of supporting at least
|
|
n intervals, where n is defined as follows:
|
|
The minimum value of n is 4.
|
|
The default of n is 32.
|
|
The maximum value of n is 96.
|
|
|
|
The value of this object will be n unless performance
|
|
monitoring was (re-)started for the interface within the last
|
|
(n*15) minutes, in which case the value will be the number of
|
|
complete 15-minute intervals since measurement was
|
|
(re-)started."
|
|
::= { optIfPerfMonIntervalEntry 3 }
|
|
|
|
optIfPerfMonIntervalNumInvalidIntervals OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..96)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intervals in the range from 0 to
|
|
optIfPerfMonIntervalNumIntervals for which no performance
|
|
monitoring data is available and/or the data is invalid."
|
|
::= { optIfPerfMonIntervalEntry 4 }
|
|
|
|
-- the optIfOTSn group
|
|
-- This group handles the configuration and performance
|
|
-- monitoring objects for OTS layers.
|
|
|
|
-- OTSn config table
|
|
|
|
optIfOTSnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn configuration information."
|
|
::= { optIfOTSn 1 }
|
|
|
|
optIfOTSnConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnConfigTable 1 }
|
|
|
|
OptIfOTSnConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnDirectionality OptIfDirectionality,
|
|
optIfOTSnAprStatus SnmpAdminString,
|
|
optIfOTSnAprControl SnmpAdminString,
|
|
optIfOTSnTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfOTSnDAPIExpected OptIfExDAPI,
|
|
optIfOTSnSAPIExpected OptIfExSAPI,
|
|
optIfOTSnTraceIdentifierAccepted OptIfAcTI,
|
|
optIfOTSnTIMDetMode OptIfTIMDetMode,
|
|
optIfOTSnTIMActEnabled TruthValue,
|
|
optIfOTSnCurrentStatus BITS
|
|
}
|
|
|
|
optIfOTSnDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOTSnConfigEntry 1 }
|
|
|
|
optIfOTSnAprStatus OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the Automatic
|
|
Power Reduction (APR) function of the entity. Valid
|
|
values are 'on' and 'off'."
|
|
::= { optIfOTSnConfigEntry 2 }
|
|
|
|
optIfOTSnAprControl OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a UTF-8 encoded string that specifies Automatic
|
|
Power Reduction (APR) control actions requested of this entity
|
|
(when written) and that returns the current APR control state
|
|
of this entity (when read). The values are implementation-defined.
|
|
Any implementation that instantiates this object must document the
|
|
set of values that it allows to be written, the set of values
|
|
that it will return, and what each of those values means."
|
|
::= { optIfOTSnConfigEntry 3 }
|
|
|
|
optIfOTSnTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value source(2) or bidirectional(3).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
If no value is ever set by a management entity for the object
|
|
optIfOTSnTraceIdentifierTransmitted, system-specific default
|
|
value will be used. Any implementation that instantiates this
|
|
object must document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfOTSnConfigEntry 4 }
|
|
|
|
optIfOTSnDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect if
|
|
optIfOTSnTIMDetMode has the value off(1) or sapi(3).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 5 }
|
|
|
|
optIfOTSnSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect if
|
|
optIfOTSnTIMDetMode has the value off(1) or dapi(2).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 6 }
|
|
|
|
optIfOTSnTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier received.
|
|
This object is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). Its value is unspecified
|
|
if optIfOTSnCurrentStatus has either or both of the
|
|
losO(5) and los(6) bits set.
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI')."
|
|
::= { optIfOTSnConfigEntry 7 }
|
|
|
|
optIfOTSnTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function. This object is applicable
|
|
when optIfOTSnDirectionality has the value sink(1)
|
|
or bidirectional(3). The default value is off(1).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
The default value of this object is off(1)."
|
|
::= { optIfOTSnConfigEntry 8 }
|
|
|
|
optIfOTSnTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled. This object
|
|
is applicable when optIfOTSnDirectionality has the
|
|
value sink(1) or bidirectional(3). It has no effect
|
|
when the value of optIfOTSnTIMDetMode is off(1).
|
|
This object does not apply to reduced-capability systems (i.e.,
|
|
those for which optIfOTMnReduced has the value true(1)) or
|
|
at IrDI interfaces (i.e., when optIfOTMnInterfaceType field 1
|
|
has the value 'IrDI').
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTSnConfigEntry 9 }
|
|
|
|
optIfOTSnCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
bdiP(0),
|
|
bdiO(1),
|
|
bdi(2),
|
|
tim(3),
|
|
losP(4),
|
|
losO(5),
|
|
los(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable when optIfOTSnDirectionality
|
|
has the value sink(1) or bidirectional(3). In
|
|
reduced-capability systems or at IrDI interfaces
|
|
the only bit position that may be set is los(6)."
|
|
::= { optIfOTSnConfigEntry 10 }
|
|
|
|
-- OTSn sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOTSnSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOTSn 2 }
|
|
|
|
optIfOTSnSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkCurrentTable 1 }
|
|
|
|
OptIfOTSnSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOTSnSinkCurrentInputPower Integer32,
|
|
optIfOTSnSinkCurrentLowInputPower Integer32,
|
|
optIfOTSnSinkCurrentHighInputPower Integer32,
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentOutputPower Integer32,
|
|
optIfOTSnSinkCurrentLowOutputPower Integer32,
|
|
optIfOTSnSinkCurrentHighOutputPower Integer32,
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOTSnSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkCurrentEntry 1 }
|
|
|
|
optIfOTSnSinkCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOTSnSinkCurrentEntry 2 }
|
|
|
|
optIfOTSnSinkCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 3 }
|
|
|
|
optIfOTSnSinkCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 4 }
|
|
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOTSnSinkCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 5 }
|
|
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOTSnSinkCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 6 }
|
|
|
|
optIfOTSnSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOTSnSinkCurrentEntry 7 }
|
|
|
|
optIfOTSnSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 8 }
|
|
|
|
optIfOTSnSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSinkCurrentEntry 9 }
|
|
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOTSnSinkCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 10 }
|
|
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOTSnSinkCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSinkCurrentEntry 11 }
|
|
|
|
-- OTSn sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOTSnSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OTSn sink performance monitoring
|
|
information."
|
|
::= { optIfOTSn 3 }
|
|
|
|
optIfOTSnSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOTSnSinkIntervalNumber }
|
|
::= { optIfOTSnSinkIntervalTable 1 }
|
|
|
|
OptIfOTSnSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOTSnSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOTSnSinkIntervalLastInputPower Integer32,
|
|
optIfOTSnSinkIntervalLowInputPower Integer32,
|
|
optIfOTSnSinkIntervalHighInputPower Integer32,
|
|
optIfOTSnSinkIntervalLastOutputPower Integer32,
|
|
optIfOTSnSinkIntervalLowOutputPower Integer32,
|
|
optIfOTSnSinkIntervalHighOutputPower Integer32
|
|
|
|
}
|
|
|
|
optIfOTSnSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOTSnSinkIntervalEntry 1 }
|
|
|
|
optIfOTSnSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkIntervalEntry 2 }
|
|
|
|
optIfOTSnSinkIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 3 }
|
|
|
|
optIfOTSnSinkIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 4 }
|
|
|
|
|
|
optIfOTSnSinkIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 5 }
|
|
|
|
optIfOTSnSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 6 }
|
|
|
|
optIfOTSnSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 7 }
|
|
|
|
optIfOTSnSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSinkIntervalEntry 8 }
|
|
|
|
-- OTSn sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOTSn 4 }
|
|
|
|
optIfOTSnSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkCurDayTable 1 }
|
|
|
|
OptIfOTSnSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOTSnSinkCurDayLowInputPower Integer32,
|
|
optIfOTSnSinkCurDayHighInputPower Integer32,
|
|
optIfOTSnSinkCurDayLowOutputPower Integer32,
|
|
optIfOTSnSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkCurDayEntry 1 }
|
|
|
|
optIfOTSnSinkCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 2 }
|
|
|
|
optIfOTSnSinkCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 3 }
|
|
|
|
optIfOTSnSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 4 }
|
|
|
|
optIfOTSnSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSinkCurDayEntry 5 }
|
|
|
|
-- OTSn sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOTSn 5 }
|
|
|
|
optIfOTSnSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSinkPrevDayTable 1 }
|
|
|
|
|
|
OptIfOTSnSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOTSnSinkPrevDayLastInputPower Integer32,
|
|
optIfOTSnSinkPrevDayLowInputPower Integer32,
|
|
optIfOTSnSinkPrevDayHighInputPower Integer32,
|
|
optIfOTSnSinkPrevDayLastOutputPower Integer32,
|
|
optIfOTSnSinkPrevDayLowOutputPower Integer32,
|
|
optIfOTSnSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSinkPrevDayEntry 1 }
|
|
|
|
optIfOTSnSinkPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 2 }
|
|
|
|
optIfOTSnSinkPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 3 }
|
|
|
|
optIfOTSnSinkPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 4 }
|
|
|
|
|
|
optIfOTSnSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 5 }
|
|
|
|
optIfOTSnSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 6 }
|
|
|
|
optIfOTSnSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSinkPrevDayEntry 7 }
|
|
|
|
-- OTSn source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOTSnSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOTSn 6 }
|
|
|
|
optIfOTSnSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcCurrentTable 1 }
|
|
|
|
OptIfOTSnSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOTSnSrcCurrentOutputPower Integer32,
|
|
optIfOTSnSrcCurrentLowOutputPower Integer32,
|
|
optIfOTSnSrcCurrentHighOutputPower Integer32,
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentInputPower Integer32,
|
|
optIfOTSnSrcCurrentLowInputPower Integer32,
|
|
optIfOTSnSrcCurrentHighInputPower Integer32,
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOTSnSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcCurrentEntry 1 }
|
|
|
|
optIfOTSnSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOTSnSrcCurrentEntry 2 }
|
|
|
|
optIfOTSnSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 3 }
|
|
|
|
|
|
optIfOTSnSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 4 }
|
|
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOTSnSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 5 }
|
|
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOTSnSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 6 }
|
|
|
|
optIfOTSnSrcCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOTSnSrcCurrentEntry 7 }
|
|
|
|
optIfOTSnSrcCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
|
|
DESCRIPTION
|
|
|
|
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 8 }
|
|
|
|
optIfOTSnSrcCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOTSnSrcCurrentEntry 9 }
|
|
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOTSnSrcCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 10 }
|
|
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOTSnSrcCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOTSnSrcCurrentEntry 11 }
|
|
|
|
-- OTSn source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOTSnSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OTSn source performance monitoring
|
|
information."
|
|
::= { optIfOTSn 7 }
|
|
|
|
|
|
optIfOTSnSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOTSnSrcIntervalNumber }
|
|
::= { optIfOTSnSrcIntervalTable 1 }
|
|
|
|
OptIfOTSnSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOTSnSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOTSnSrcIntervalLastOutputPower Integer32,
|
|
optIfOTSnSrcIntervalLowOutputPower Integer32,
|
|
optIfOTSnSrcIntervalHighOutputPower Integer32,
|
|
optIfOTSnSrcIntervalLastInputPower Integer32,
|
|
optIfOTSnSrcIntervalLowInputPower Integer32,
|
|
optIfOTSnSrcIntervalHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOTSnSrcIntervalEntry 1 }
|
|
|
|
optIfOTSnSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcIntervalEntry 2 }
|
|
|
|
optIfOTSnSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 3 }
|
|
|
|
|
|
optIfOTSnSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 4 }
|
|
|
|
optIfOTSnSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 5 }
|
|
|
|
optIfOTSnSrcIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 6 }
|
|
|
|
optIfOTSnSrcIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOTSnSrcIntervalEntry 7 }
|
|
|
|
optIfOTSnSrcIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
|
|
|
|
::= { optIfOTSnSrcIntervalEntry 8 }
|
|
|
|
|
|
-- OTSn source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOTSn 8 }
|
|
|
|
optIfOTSnSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcCurDayTable 1 }
|
|
|
|
OptIfOTSnSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOTSnSrcCurDayLowOutputPower Integer32,
|
|
optIfOTSnSrcCurDayHighOutputPower Integer32,
|
|
optIfOTSnSrcCurDayLowInputPower Integer32,
|
|
optIfOTSnSrcCurDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcCurDayEntry 1 }
|
|
|
|
optIfOTSnSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 2 }
|
|
|
|
optIfOTSnSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 3 }
|
|
|
|
optIfOTSnSrcCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 4 }
|
|
|
|
optIfOTSnSrcCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOTSnSrcCurDayEntry 5 }
|
|
|
|
-- OTSn source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOTSnSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTSn source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOTSn 9 }
|
|
|
|
|
|
optIfOTSnSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTSn source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTSnSrcPrevDayTable 1 }
|
|
|
|
OptIfOTSnSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOTSnSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOTSnSrcPrevDayLastOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayLowOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayHighOutputPower Integer32,
|
|
optIfOTSnSrcPrevDayLastInputPower Integer32,
|
|
optIfOTSnSrcPrevDayLowInputPower Integer32,
|
|
optIfOTSnSrcPrevDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOTSnSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOTSnSrcPrevDayEntry 1 }
|
|
|
|
optIfOTSnSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 2 }
|
|
|
|
optIfOTSnSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
|
|
|
|
::= { optIfOTSnSrcPrevDayEntry 3 }
|
|
|
|
optIfOTSnSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 4 }
|
|
|
|
optIfOTSnSrcPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 5 }
|
|
|
|
optIfOTSnSrcPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 6 }
|
|
|
|
optIfOTSnSrcPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOTSnSrcPrevDayEntry 7 }
|
|
|
|
|
|
-- the optIfOMSn group
|
|
-- This group handles the configuration and performance monitoring
|
|
-- information for OMS layers.
|
|
|
|
-- OMSn config table
|
|
|
|
optIfOMSnConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn configuration information."
|
|
::= { optIfOMSn 1 }
|
|
|
|
optIfOMSnConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnConfigTable 1 }
|
|
|
|
OptIfOMSnConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnDirectionality OptIfDirectionality,
|
|
optIfOMSnCurrentStatus BITS
|
|
}
|
|
|
|
optIfOMSnDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOMSnConfigEntry 1 }
|
|
|
|
optIfOMSnCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
ssfP(0),
|
|
ssfO(1),
|
|
ssf(2),
|
|
bdiP(3),
|
|
bdiO(4),
|
|
bdi(5),
|
|
losP(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable only to full capability
|
|
systems whose interface type is IaDI and for which
|
|
|
|
|
|
optIfOMSnDirectionality has the value sink(1) or
|
|
bidirectional(3)."
|
|
::= { optIfOMSnConfigEntry 2 }
|
|
|
|
-- OMSn sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOMSnSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOMSn 2 }
|
|
|
|
optIfOMSnSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkCurrentTable 1 }
|
|
|
|
OptIfOMSnSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOMSnSinkCurrentAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentOutputPower Integer32,
|
|
optIfOMSnSinkCurrentLowOutputPower Integer32,
|
|
optIfOMSnSinkCurrentHighOutputPower Integer32,
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOMSnSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkCurrentEntry 1 }
|
|
|
|
optIfOMSnSinkCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power of all the DWDM input
|
|
channels."
|
|
::= { optIfOMSnSinkCurrentEntry 2 }
|
|
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 3 }
|
|
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 4 }
|
|
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOMSnSinkCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 5 }
|
|
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOMSnSinkCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 6 }
|
|
|
|
optIfOMSnSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOMSnSinkCurrentEntry 7 }
|
|
|
|
optIfOMSnSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 8 }
|
|
|
|
optIfOMSnSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSinkCurrentEntry 9 }
|
|
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOMSnSinkCurrentOutputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 10 }
|
|
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOMSnSinkCurrentOutputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSinkCurrentEntry 11 }
|
|
|
|
-- OMSn sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOMSnSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OMSn sink performance monitoring
|
|
information."
|
|
::= { optIfOMSn 3 }
|
|
|
|
optIfOMSnSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOMSnSinkIntervalNumber }
|
|
::= { optIfOMSnSinkIntervalTable 1 }
|
|
|
|
OptIfOMSnSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOMSnSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkIntervalLastOutputPower Integer32,
|
|
optIfOMSnSinkIntervalLowOutputPower Integer32,
|
|
optIfOMSnSinkIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 1 }
|
|
|
|
optIfOMSnSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkIntervalEntry 2 }
|
|
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 3 }
|
|
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 4 }
|
|
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 5 }
|
|
|
|
optIfOMSnSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 6 }
|
|
|
|
optIfOMSnSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 7 }
|
|
|
|
optIfOMSnSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the interval."
|
|
::= { optIfOMSnSinkIntervalEntry 8 }
|
|
|
|
-- OMSn sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOMSn 4 }
|
|
|
|
optIfOMSnSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkCurDayTable 1 }
|
|
|
|
OptIfOMSnSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkCurDayLowOutputPower Integer32,
|
|
optIfOMSnSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkCurDayEntry 1 }
|
|
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 2 }
|
|
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 3 }
|
|
|
|
optIfOMSnSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 4 }
|
|
|
|
optIfOMSnSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSinkCurDayEntry 5 }
|
|
|
|
-- OMSn sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOMSn 5 }
|
|
|
|
optIfOMSnSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSinkPrevDayTable 1 }
|
|
|
|
OptIfOMSnSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower Integer32,
|
|
optIfOMSnSinkPrevDayLastOutputPower Integer32,
|
|
optIfOMSnSinkPrevDayLowOutputPower Integer32,
|
|
optIfOMSnSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSinkPrevDayEntry 1 }
|
|
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 2 }
|
|
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 3 }
|
|
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 4 }
|
|
|
|
optIfOMSnSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 5 }
|
|
|
|
optIfOMSnSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 6 }
|
|
|
|
optIfOMSnSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power at the output
|
|
during the previous 24-hour interval."
|
|
::= { optIfOMSnSinkPrevDayEntry 7 }
|
|
|
|
-- OMSn source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOMSnSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOMSn 6 }
|
|
|
|
optIfOMSnSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcCurrentTable 1 }
|
|
|
|
OptIfOMSnSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOMSnSrcCurrentOutputPower Integer32,
|
|
optIfOMSnSrcCurrentLowOutputPower Integer32,
|
|
optIfOMSnSrcCurrentHighOutputPower Integer32,
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOMSnSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcCurrentEntry 1 }
|
|
|
|
optIfOMSnSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOMSnSrcCurrentEntry 2 }
|
|
|
|
optIfOMSnSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 3 }
|
|
|
|
optIfOMSnSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 4 }
|
|
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOMSnSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 5 }
|
|
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOMSnSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 6 }
|
|
|
|
optIfOMSnSrcCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power at the input."
|
|
::= { optIfOMSnSrcCurrentEntry 7 }
|
|
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 8 }
|
|
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOMSnSrcCurrentEntry 9 }
|
|
|
|
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOMSnSrcCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 10 }
|
|
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOMSnSrcCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOMSnSrcCurrentEntry 11 }
|
|
|
|
|
|
-- OMSn source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOMSnSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OMSn source performance monitoring
|
|
information."
|
|
::= { optIfOMSn 7 }
|
|
|
|
optIfOMSnSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOMSnSrcIntervalNumber }
|
|
::= { optIfOMSnSrcIntervalTable 1 }
|
|
|
|
OptIfOMSnSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOMSnSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOMSnSrcIntervalLastOutputPower Integer32,
|
|
optIfOMSnSrcIntervalLowOutputPower Integer32,
|
|
optIfOMSnSrcIntervalHighOutputPower Integer32,
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower Integer32,
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 1 }
|
|
|
|
optIfOMSnSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcIntervalEntry 2 }
|
|
|
|
optIfOMSnSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 3 }
|
|
|
|
optIfOMSnSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 4 }
|
|
|
|
optIfOMSnSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOMSnSrcIntervalEntry 5 }
|
|
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 6 }
|
|
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 7 }
|
|
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the interval."
|
|
::= { optIfOMSnSrcIntervalEntry 8 }
|
|
|
|
-- OMSn source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOMSn 8 }
|
|
|
|
optIfOMSnSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcCurDayTable 1 }
|
|
|
|
OptIfOMSnSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOMSnSrcCurDayLowOutputPower Integer32,
|
|
optIfOMSnSrcCurDayHighOutputPower Integer32,
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcCurDayEntry 1 }
|
|
|
|
optIfOMSnSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 2 }
|
|
|
|
optIfOMSnSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 3 }
|
|
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 4 }
|
|
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOMSnSrcCurDayEntry 5 }
|
|
|
|
-- OMSn source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOMSnSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOMSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OMSn source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOMSn 9 }
|
|
|
|
optIfOMSnSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOMSnSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OMSn source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOMSnSrcPrevDayTable 1 }
|
|
|
|
|
|
OptIfOMSnSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOMSnSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOMSnSrcPrevDayLastOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayLowOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayHighOutputPower Integer32,
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOMSnSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOMSnSrcPrevDayEntry 1 }
|
|
|
|
optIfOMSnSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 2 }
|
|
|
|
optIfOMSnSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 3 }
|
|
|
|
optIfOMSnSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 4 }
|
|
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 5 }
|
|
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 6 }
|
|
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOMSnSrcPrevDayEntry 7 }
|
|
|
|
-- the optIfOChGroup group
|
|
-- This group handles the configuration and performance monitoring
|
|
-- information for OChGroup layers.
|
|
|
|
-- OChGroup config table
|
|
|
|
optIfOChGroupConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup configuration information."
|
|
::= { optIfOChGroup 1 }
|
|
|
|
optIfOChGroupConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupConfigTable 1 }
|
|
|
|
OptIfOChGroupConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupDirectionality OptIfDirectionality
|
|
}
|
|
|
|
optIfOChGroupDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOChGroupConfigEntry 1 }
|
|
|
|
-- OChGroup sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChGroupSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOChGroup 2 }
|
|
|
|
optIfOChGroupSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkCurrentTable 1 }
|
|
|
|
OptIfOChGroupSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOChGroupSinkCurrentAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentHighOutputPower Integer32,
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkCurrentEntry 1 }
|
|
|
|
optIfOChGroupSinkCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power of all the DWDM input
|
|
channels in the OChGroup."
|
|
::= { optIfOChGroupSinkCurrentEntry 2 }
|
|
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 3 }
|
|
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 4 }
|
|
|
|
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on aggregated input power. If
|
|
optIfOChGroupSinkCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 5 }
|
|
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on aggregated input power. If
|
|
optIfOChGroupSinkCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 6 }
|
|
|
|
optIfOChGroupSinkCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output
|
|
in the OChGroup."
|
|
::= { optIfOChGroupSinkCurrentEntry 7 }
|
|
|
|
optIfOChGroupSinkCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 8 }
|
|
|
|
optIfOChGroupSinkCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the current 15-minute interval."
|
|
::= { optIfOChGroupSinkCurrentEntry 9 }
|
|
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on the output power. If
|
|
optIfOChGroupSinkCurrentOutputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 10 }
|
|
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on the output power. If
|
|
optIfOChGroupSinkCurrentOutputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSinkCurrentEntry 11 }
|
|
|
|
-- OChGroup sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChGroupSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OChGroup sink performance monitoring
|
|
information."
|
|
::= { optIfOChGroup 3 }
|
|
|
|
optIfOChGroupSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChGroupSinkIntervalNumber }
|
|
::= { optIfOChGroupSinkIntervalTable 1 }
|
|
|
|
OptIfOChGroupSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOChGroupSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkIntervalLastOutputPower Integer32,
|
|
optIfOChGroupSinkIntervalLowOutputPower Integer32,
|
|
optIfOChGroupSinkIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 1 }
|
|
|
|
optIfOChGroupSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkIntervalEntry 2 }
|
|
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 3 }
|
|
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 4 }
|
|
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 5 }
|
|
|
|
optIfOChGroupSinkIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 6 }
|
|
|
|
optIfOChGroupSinkIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 7 }
|
|
|
|
optIfOChGroupSinkIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the interval."
|
|
::= { optIfOChGroupSinkIntervalEntry 8 }
|
|
|
|
-- OChGroup sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOChGroup 4 }
|
|
|
|
optIfOChGroupSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkCurDayTable 1 }
|
|
|
|
OptIfOChGroupSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkCurDayLowOutputPower Integer32,
|
|
optIfOChGroupSinkCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkCurDayEntry 1 }
|
|
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 2 }
|
|
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 3 }
|
|
|
|
optIfOChGroupSinkCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 4 }
|
|
|
|
optIfOChGroupSinkCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the current 24-hour interval."
|
|
::= { optIfOChGroupSinkCurDayEntry 5 }
|
|
|
|
-- OChGroup sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOChGroup 5 }
|
|
|
|
optIfOChGroupSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSinkPrevDayTable 1 }
|
|
|
|
OptIfOChGroupSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLastOutputPower Integer32,
|
|
optIfOChGroupSinkPrevDayLowOutputPower Integer32,
|
|
optIfOChGroupSinkPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSinkPrevDayEntry 1 }
|
|
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 2 }
|
|
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 3 }
|
|
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power of all the DWDM input
|
|
channels in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 4 }
|
|
|
|
optIfOChGroupSinkPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 5 }
|
|
|
|
optIfOChGroupSinkPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 6 }
|
|
|
|
optIfOChGroupSinkPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output
|
|
in the OChGroup during the previous 24-hour interval."
|
|
::= { optIfOChGroupSinkPrevDayEntry 7 }
|
|
|
|
-- OChGroup source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChGroupSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOChGroup 6 }
|
|
|
|
optIfOChGroupSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcCurrentTable 1 }
|
|
|
|
OptIfOChGroupSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOChGroupSrcCurrentOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentHighOutputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcCurrentEntry 1 }
|
|
|
|
optIfOChGroupSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOChGroupSrcCurrentEntry 2 }
|
|
|
|
optIfOChGroupSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 3 }
|
|
|
|
optIfOChGroupSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 4 }
|
|
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOChGroupSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 5 }
|
|
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOChGroupSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 6 }
|
|
|
|
optIfOChGroupSrcCurrentAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The aggregated optical power monitored at the input."
|
|
::= { optIfOChGroupSrcCurrentEntry 7 }
|
|
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 8 }
|
|
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the current 15-minute interval."
|
|
::= { optIfOChGroupSrcCurrentEntry 9 }
|
|
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOChGroupSrcCurrentAggregatedInputPower drops to this value
|
|
or below, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 10 }
|
|
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOChGroupSrcCurrentAggregatedInputPower reaches or exceeds
|
|
this value, a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChGroupSrcCurrentEntry 11 }
|
|
|
|
-- OChGroup source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChGroupSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OChGroup source performance monitoring
|
|
information."
|
|
::= { optIfOChGroup 7 }
|
|
|
|
optIfOChGroupSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChGroupSrcIntervalNumber }
|
|
::= { optIfOChGroupSrcIntervalTable 1 }
|
|
|
|
OptIfOChGroupSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOChGroupSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOChGroupSrcIntervalLastOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalLowOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalHighOutputPower Integer32,
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 1 }
|
|
|
|
optIfOChGroupSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcIntervalEntry 2 }
|
|
|
|
optIfOChGroupSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 3 }
|
|
|
|
optIfOChGroupSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 4 }
|
|
|
|
optIfOChGroupSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 5 }
|
|
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 6 }
|
|
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 7 }
|
|
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the interval."
|
|
::= { optIfOChGroupSrcIntervalEntry 8 }
|
|
|
|
-- OChGroup source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOChGroup 8 }
|
|
|
|
optIfOChGroupSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcCurDayTable 1 }
|
|
|
|
OptIfOChGroupSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSrcCurDayLowOutputPower Integer32,
|
|
optIfOChGroupSrcCurDayHighOutputPower Integer32,
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcCurDayEntry 1 }
|
|
|
|
optIfOChGroupSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 2 }
|
|
|
|
optIfOChGroupSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 3 }
|
|
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 4 }
|
|
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the current 24-hour interval."
|
|
::= { optIfOChGroupSrcCurDayEntry 5 }
|
|
|
|
-- OChGroup source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChGroupSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChGroupSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OChGroup source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOChGroup 9 }
|
|
|
|
optIfOChGroupSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChGroupSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OChGroup source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChGroupSrcPrevDayTable 1 }
|
|
|
|
OptIfOChGroupSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChGroupSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOChGroupSrcPrevDayLastOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLowOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayHighOutputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower Integer32,
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower Integer32
|
|
}
|
|
|
|
optIfOChGroupSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChGroupSrcPrevDayEntry 1 }
|
|
|
|
optIfOChGroupSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 2 }
|
|
|
|
optIfOChGroupSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 3 }
|
|
|
|
optIfOChGroupSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 4 }
|
|
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 5 }
|
|
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 6 }
|
|
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest aggregated optical power monitored at the input
|
|
during the previous 24-hour interval."
|
|
::= { optIfOChGroupSrcPrevDayEntry 7 }
|
|
|
|
-- the optIfOCh group
|
|
-- This group handles the configuration and
|
|
-- performance monitoring information for OCh layers.
|
|
|
|
-- OCh config table
|
|
|
|
optIfOChConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh configuration information."
|
|
::= { optIfOCh 1 }
|
|
|
|
optIfOChConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChConfigTable 1 }
|
|
|
|
OptIfOChConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOChDirectionality OptIfDirectionality,
|
|
optIfOChCurrentStatus BITS
|
|
}
|
|
|
|
optIfOChDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOChConfigEntry 1 }
|
|
|
|
optIfOChCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
losP(0),
|
|
los(1),
|
|
oci(2),
|
|
ssfP(3),
|
|
ssfO(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable when optIfOChDirectionality
|
|
has the value sink(1) or bidirectional(3).
|
|
In full-capability systems the bit position los(1) is not used.
|
|
In reduced-capability systems or at IrDI interfaces only
|
|
the bit positions los(1) and ssfP(3) are used."
|
|
::= { optIfOChConfigEntry 2 }
|
|
|
|
-- OCh sink current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChSinkCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOCh 2 }
|
|
|
|
optIfOChSinkCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information for an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkCurrentTable 1 }
|
|
|
|
OptIfOChSinkCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkCurrentSuspectedFlag TruthValue,
|
|
optIfOChSinkCurrentInputPower Integer32,
|
|
optIfOChSinkCurrentLowInputPower Integer32,
|
|
optIfOChSinkCurrentHighInputPower Integer32,
|
|
optIfOChSinkCurrentLowerInputPowerThreshold Integer32,
|
|
optIfOChSinkCurrentUpperInputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChSinkCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkCurrentEntry 1 }
|
|
|
|
optIfOChSinkCurrentInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the input."
|
|
::= { optIfOChSinkCurrentEntry 2 }
|
|
|
|
optIfOChSinkCurrentLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSinkCurrentEntry 3 }
|
|
|
|
optIfOChSinkCurrentHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSinkCurrentEntry 4 }
|
|
|
|
optIfOChSinkCurrentLowerInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on input power. If
|
|
optIfOChSinkCurrentInputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSinkCurrentEntry 5 }
|
|
|
|
optIfOChSinkCurrentUpperInputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on input power. If
|
|
optIfOChSinkCurrentInputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSinkCurrentEntry 6 }
|
|
|
|
-- OCh sink interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChSinkIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OCh sink performance monitoring
|
|
information."
|
|
::= { optIfOCh 3 }
|
|
|
|
optIfOChSinkIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChSinkIntervalNumber }
|
|
::= { optIfOChSinkIntervalTable 1 }
|
|
|
|
OptIfOChSinkIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkIntervalNumber OptIfIntervalNumber,
|
|
optIfOChSinkIntervalSuspectedFlag TruthValue,
|
|
optIfOChSinkIntervalLastInputPower Integer32,
|
|
optIfOChSinkIntervalLowInputPower Integer32,
|
|
optIfOChSinkIntervalHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChSinkIntervalEntry 1 }
|
|
|
|
optIfOChSinkIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkIntervalEntry 2 }
|
|
|
|
optIfOChSinkIntervalLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 3 }
|
|
|
|
optIfOChSinkIntervalLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 4 }
|
|
|
|
optIfOChSinkIntervalHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
interval."
|
|
::= { optIfOChSinkIntervalEntry 5 }
|
|
|
|
-- OCh sink current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSinkCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOCh 4 }
|
|
|
|
optIfOChSinkCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkCurDayTable 1 }
|
|
|
|
OptIfOChSinkCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkCurDaySuspectedFlag TruthValue,
|
|
optIfOChSinkCurDayLowInputPower Integer32,
|
|
optIfOChSinkCurDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkCurDayEntry 1 }
|
|
|
|
optIfOChSinkCurDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSinkCurDayEntry 2 }
|
|
|
|
optIfOChSinkCurDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSinkCurDayEntry 3 }
|
|
|
|
-- OCh sink previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSinkPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh sink performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOCh 5 }
|
|
|
|
optIfOChSinkPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSinkPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh sink performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSinkPrevDayTable 1 }
|
|
|
|
OptIfOChSinkPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSinkPrevDaySuspectedFlag TruthValue,
|
|
optIfOChSinkPrevDayLastInputPower Integer32,
|
|
optIfOChSinkPrevDayLowInputPower Integer32,
|
|
optIfOChSinkPrevDayHighInputPower Integer32
|
|
}
|
|
|
|
optIfOChSinkPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSinkPrevDayEntry 1 }
|
|
|
|
optIfOChSinkPrevDayLastInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 2 }
|
|
|
|
optIfOChSinkPrevDayLowInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 3 }
|
|
|
|
optIfOChSinkPrevDayHighInputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the input during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSinkPrevDayEntry 4 }
|
|
|
|
-- OCh source current table
|
|
-- Contains data for the current 15-minute performance monitoring
|
|
-- interval.
|
|
|
|
optIfOChSrcCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the current 15-minute interval."
|
|
::= { optIfOCh 6 }
|
|
|
|
optIfOChSrcCurrentEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the current
|
|
15-minute interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcCurrentTable 1 }
|
|
|
|
OptIfOChSrcCurrentEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcCurrentSuspectedFlag TruthValue,
|
|
optIfOChSrcCurrentOutputPower Integer32,
|
|
optIfOChSrcCurrentLowOutputPower Integer32,
|
|
optIfOChSrcCurrentHighOutputPower Integer32,
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold Integer32,
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold Integer32
|
|
}
|
|
|
|
optIfOChSrcCurrentSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcCurrentEntry 1 }
|
|
|
|
optIfOChSrcCurrentOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The optical power monitored at the output."
|
|
::= { optIfOChSrcCurrentEntry 2 }
|
|
|
|
optIfOChSrcCurrentLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSrcCurrentEntry 3 }
|
|
|
|
optIfOChSrcCurrentHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 15-minute interval."
|
|
::= { optIfOChSrcCurrentEntry 4 }
|
|
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lower limit threshold on output power. If
|
|
optIfOChSrcCurrentOutputPower drops to this value or below,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSrcCurrentEntry 5 }
|
|
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The upper limit threshold on output power. If
|
|
optIfOChSrcCurrentOutputPower reaches or exceeds this value,
|
|
a Threshold Crossing Alert (TCA) should be sent."
|
|
::= { optIfOChSrcCurrentEntry 6 }
|
|
|
|
-- OCh source interval table
|
|
-- Contains data for previous 15-minute performance monitoring
|
|
-- intervals.
|
|
|
|
optIfOChSrcIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of historical OCh source performance monitoring
|
|
information."
|
|
::= { optIfOCh 7 }
|
|
|
|
optIfOChSrcIntervalEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface during a particular
|
|
historical interval."
|
|
INDEX { ifIndex, optIfOChSrcIntervalNumber }
|
|
::= { optIfOChSrcIntervalTable 1 }
|
|
|
|
OptIfOChSrcIntervalEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcIntervalNumber OptIfIntervalNumber,
|
|
optIfOChSrcIntervalSuspectedFlag TruthValue,
|
|
optIfOChSrcIntervalLastOutputPower Integer32,
|
|
optIfOChSrcIntervalLowOutputPower Integer32,
|
|
optIfOChSrcIntervalHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcIntervalNumber OBJECT-TYPE
|
|
SYNTAX OptIfIntervalNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies the interval."
|
|
::= { optIfOChSrcIntervalEntry 1 }
|
|
|
|
optIfOChSrcIntervalSuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcIntervalEntry 2 }
|
|
|
|
optIfOChSrcIntervalLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 3 }
|
|
|
|
optIfOChSrcIntervalLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 4 }
|
|
|
|
optIfOChSrcIntervalHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
interval."
|
|
::= { optIfOChSrcIntervalEntry 5 }
|
|
|
|
-- OCh source current day table
|
|
-- Contains data for the current 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSrcCurDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the current 24-hour interval."
|
|
::= { optIfOCh 8 }
|
|
|
|
optIfOChSrcCurDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcCurDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the current
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcCurDayTable 1 }
|
|
|
|
OptIfOChSrcCurDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcCurDaySuspectedFlag TruthValue,
|
|
optIfOChSrcCurDayLowOutputPower Integer32,
|
|
optIfOChSrcCurDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcCurDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcCurDayEntry 1 }
|
|
|
|
optIfOChSrcCurDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSrcCurDayEntry 2 }
|
|
|
|
optIfOChSrcCurDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
current 24-hour interval."
|
|
::= { optIfOChSrcCurDayEntry 3 }
|
|
|
|
-- OCh source previous day table
|
|
-- Contains data for the previous 24-hour performance
|
|
-- monitoring interval.
|
|
|
|
optIfOChSrcPrevDayTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOChSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OCh source performance monitoring information for
|
|
the previous 24-hour interval."
|
|
::= { optIfOCh 9 }
|
|
|
|
optIfOChSrcPrevDayEntry OBJECT-TYPE
|
|
SYNTAX OptIfOChSrcPrevDayEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OCh source performance
|
|
monitoring information of an interface for the previous
|
|
24-hour interval."
|
|
INDEX { ifIndex }
|
|
::= { optIfOChSrcPrevDayTable 1 }
|
|
|
|
OptIfOChSrcPrevDayEntry ::=
|
|
SEQUENCE {
|
|
optIfOChSrcPrevDaySuspectedFlag TruthValue,
|
|
optIfOChSrcPrevDayLastOutputPower Integer32,
|
|
optIfOChSrcPrevDayLowOutputPower Integer32,
|
|
optIfOChSrcPrevDayHighOutputPower Integer32
|
|
}
|
|
|
|
optIfOChSrcPrevDaySuspectedFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If true, the data in this entry may be unreliable."
|
|
::= { optIfOChSrcPrevDayEntry 1 }
|
|
|
|
optIfOChSrcPrevDayLastOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 2 }
|
|
|
|
optIfOChSrcPrevDayLowOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 3 }
|
|
|
|
optIfOChSrcPrevDayHighOutputPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "0.1 dbm"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest optical power monitored at the output during the
|
|
previous 24-hour interval."
|
|
::= { optIfOChSrcPrevDayEntry 4 }
|
|
|
|
-- the optIfOTUk group
|
|
-- This group handles the configuration
|
|
-- information for OTUk layers.
|
|
|
|
-- OTUk config table
|
|
|
|
optIfOTUkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfOTUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of OTUk configuration information."
|
|
::= { optIfOTUk 1 }
|
|
|
|
optIfOTUkConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfOTUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains OTUk configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfOTUkConfigTable 1 }
|
|
|
|
OptIfOTUkConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfOTUkDirectionality OptIfDirectionality,
|
|
optIfOTUkBitRateK OptIfBitRateK,
|
|
optIfOTUkTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfOTUkDAPIExpected OptIfExDAPI,
|
|
optIfOTUkSAPIExpected OptIfExSAPI,
|
|
optIfOTUkTraceIdentifierAccepted OptIfAcTI,
|
|
optIfOTUkTIMDetMode OptIfTIMDetMode,
|
|
optIfOTUkTIMActEnabled TruthValue,
|
|
optIfOTUkDEGThr OptIfDEGThr,
|
|
optIfOTUkDEGM OptIfDEGM,
|
|
optIfOTUkSinkAdaptActive TruthValue,
|
|
optIfOTUkSourceAdaptActive TruthValue,
|
|
optIfOTUkSinkFECEnabled TruthValue,
|
|
optIfOTUkCurrentStatus BITS
|
|
}
|
|
|
|
optIfOTUkDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfOTUkConfigEntry 1 }
|
|
|
|
optIfOTUkBitRateK OBJECT-TYPE
|
|
SYNTAX OptIfBitRateK
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bit rate of the entity."
|
|
::= { optIfOTUkConfigEntry 2 }
|
|
|
|
optIfOTUkTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfOTUkDirectionality
|
|
has the value source(2) or bidirectional(3). It must not
|
|
be instantiated in rows where optIfOTUkDirectionality
|
|
has the value sink(1).
|
|
If no value is ever set by a management entity for this
|
|
object, system-specific default value will be used.
|
|
Any implementation that instantiates this object must
|
|
document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfOTUkConfigEntry 3 }
|
|
|
|
optIfOTUkDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfOTUkConfigEntry 4 }
|
|
|
|
optIfOTUkSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfOTUkConfigEntry 5 }
|
|
|
|
optIfOTUkTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The value of this object is unspecified when
|
|
optIfOTUkCurrentStatus indicates a near-end defect
|
|
(i.e., ssf(3), lof(4), ais(5), lom(6)) that prevents
|
|
extraction of the trace message."
|
|
::= { optIfOTUkConfigEntry 6 }
|
|
|
|
optIfOTUkTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is off(1)."
|
|
::= { optIfOTUkConfigEntry 7 }
|
|
|
|
optIfOTUkTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
This object has no effect when optIfOTUkTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 8 }
|
|
|
|
optIfOTUkDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfOTUkDEGThr.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfOTUkConfigEntry 9 }
|
|
|
|
optIfOTUkDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfOTUkDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfOTUkConfigEntry 10 }
|
|
|
|
optIfOTUkSinkAdaptActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the sink adaptation function is activated or
|
|
not.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 11 }
|
|
|
|
optIfOTUkSourceAdaptActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the source adaptation function is activated or
|
|
not.
|
|
This object is only applicable to the source function, i.e.,
|
|
only when optIfOTUkDirectionality has the value source(2)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value sink(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfOTUkConfigEntry 12 }
|
|
|
|
optIfOTUkSinkFECEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If Forward Error Correction (FEC) is supported, this object
|
|
indicates whether FEC at the OTUk sink adaptation function is
|
|
enabled or not.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2).
|
|
The default value of this object is true(1)."
|
|
::= { optIfOTUkConfigEntry 13 }
|
|
|
|
optIfOTUkCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
tim(0),
|
|
deg(1),
|
|
bdi(2),
|
|
ssf(3),
|
|
lof(4),
|
|
ais(5),
|
|
lom(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfOTUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfOTUkDirectionality has the value source(2)."
|
|
::= { optIfOTUkConfigEntry 14 }
|
|
|
|
-- GCC0 config table
|
|
|
|
optIfGCC0ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfGCC0ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of GCC0 configuration information."
|
|
::= { optIfOTUk 2 }
|
|
|
|
|
|
optIfGCC0ConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfGCC0ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains GCC0 configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfOTUkConfigEntry.
|
|
Separate source and/or sink instances may exist
|
|
for a given ifIndex value, or a single bidirectional
|
|
instance may exist, but a bidirectional instance may
|
|
not coexist with a source or sink instance.
|
|
Instances of this conceptual row persist across
|
|
agent restarts."
|
|
INDEX { ifIndex, optIfGCC0Directionality }
|
|
::= { optIfGCC0ConfigTable 1 }
|
|
|
|
OptIfGCC0ConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfGCC0Directionality OptIfDirectionality,
|
|
optIfGCC0Application SnmpAdminString,
|
|
optIfGCC0RowStatus RowStatus
|
|
}
|
|
|
|
optIfGCC0Directionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity.
|
|
The values source(2) and bidirectional(3) are
|
|
not allowed if the corresponding instance of
|
|
optIfOTUkDirectionality has the value sink(1).
|
|
The values sink(1) and bidirectional(3) are
|
|
not allowed if the corresponding instance of
|
|
optIfOTUkDirectionality has the value source(2)."
|
|
::= { optIfGCC0ConfigEntry 1 }
|
|
|
|
optIfGCC0Application OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the application transported by the GCC0 entity.
|
|
Example applications are ECC, User data channel.
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC0RowStatus has the value active(1)."
|
|
::= { optIfGCC0ConfigEntry 2 }
|
|
|
|
optIfGCC0RowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfGCC0 config table.
|
|
It is used to model the addGCC0Access and removeGCC0Access
|
|
operations of an OTUk_TTP for GCC0 access control as defined
|
|
in G.874.1. Setting RowStatus to createAndGo or createAndWait
|
|
implies addGCC0Access. Setting RowStatus to destroy implies
|
|
removeGCC0Access."
|
|
::= { optIfGCC0ConfigEntry 3 }
|
|
|
|
-- the optIfODUk group
|
|
-- This group handles the configuration information
|
|
-- for the ODUk layers.
|
|
|
|
-- ODUk config table
|
|
|
|
optIfODUkConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk configuration information."
|
|
::= { optIfODUk 1 }
|
|
|
|
optIfODUkConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfODUkConfigTable 1 }
|
|
|
|
OptIfODUkConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkDirectionality OptIfDirectionality,
|
|
optIfODUkBitRateK OptIfBitRateK,
|
|
optIfODUkTcmFieldsInUse BITS,
|
|
optIfODUkPositionSeqCurrentSize Unsigned32,
|
|
optIfODUkTtpPresent TruthValue
|
|
}
|
|
|
|
optIfODUkDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfDirectionality
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the entity."
|
|
::= { optIfODUkConfigEntry 1 }
|
|
|
|
optIfODUkBitRateK OBJECT-TYPE
|
|
SYNTAX OptIfBitRateK
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the bit rate of the entity."
|
|
::= { optIfODUkConfigEntry 2 }
|
|
|
|
optIfODUkTcmFieldsInUse OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
tcmField1(0),
|
|
tcmField2(1),
|
|
tcmField3(2),
|
|
tcmField4(3),
|
|
tcmField5(4),
|
|
tcmField6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the TCM field(s) that are currently in use.
|
|
The positions of the bits correspond to the TCM fields.
|
|
A bit that is set to 1 means that the corresponding TCM
|
|
field is used. This object will be updated when rows are
|
|
created in or deleted from the optIfODUkTConfigTable, or
|
|
the optIfODUkTNimConfigTable."
|
|
::= { optIfODUkConfigEntry 3 }
|
|
|
|
optIfODUkPositionSeqCurrentSize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the current size of the position
|
|
sequence (i.e., number of TCM function and/or GCC12
|
|
access that have been created in the ODUk interface).
|
|
When the value of this variable is greater than zero,
|
|
it means that one or more TCM function and/or GCC12
|
|
access have been created in the ODUk interface. In this
|
|
case, there will be as many rows in the
|
|
optIfODUkPositionSeqTable as the value of
|
|
optIfODUkPositionSeqCurrentSize corresponding to this
|
|
ODUk interface, one row for each TCM function or GCC12
|
|
access. The position of the TCM function and/or
|
|
GCC12 access within the sequence is indicated by the
|
|
optIfODUkPositionSeqPosition variable in
|
|
optIfODUkPositionSeqTable.
|
|
The optIfODUkPositionSeqTable also provides pointers
|
|
to the corresponding TCM function (optIfODUkT) and
|
|
GCC12 access (optIfGCC12) entities."
|
|
::= { optIfODUkConfigEntry 4 }
|
|
|
|
optIfODUkTtpPresent OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object has the value true(1) if the ifEntry under which
|
|
it is instantiated contains an ODUk Trail Termination Point,
|
|
i.e., is the endpoint of an ODUk path. In that case there
|
|
will be a corresponding row in the ODUk TTP config table and
|
|
it will not be possible to create corresponding rows in the
|
|
ODUk NIM config table. This object has the value false(2)
|
|
if the ifEntry under which it is instantiated contains an
|
|
intermediate ODUk Connection Termination Point. In that case
|
|
there is no corresponding row in the ODUk TTP config table,
|
|
but it will be possible to create corresponding rows in the
|
|
ODUk NIM config table. This object also affects the allowable
|
|
options in rows created in the GCC12 config table and in the
|
|
ODUkT config table, as specified in the DESCRIPTION clauses
|
|
of the columns in those tables."
|
|
::= { optIfODUkConfigEntry 5 }
|
|
|
|
-- ODUk Trail Termination Point (TTP) config table
|
|
|
|
optIfODUkTtpConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTtpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk TTP configuration information."
|
|
::= { optIfODUk 2 }
|
|
|
|
optIfODUkTtpConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTtpConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk TTP configuration
|
|
information of an interface."
|
|
INDEX { ifIndex }
|
|
::= { optIfODUkTtpConfigTable 1 }
|
|
|
|
OptIfODUkTtpConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTtpTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfODUkTtpDAPIExpected OptIfExDAPI,
|
|
optIfODUkTtpSAPIExpected OptIfExSAPI,
|
|
optIfODUkTtpTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTtpTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTtpTIMActEnabled TruthValue,
|
|
optIfODUkTtpDEGThr OptIfDEGThr,
|
|
optIfODUkTtpDEGM OptIfDEGM,
|
|
optIfODUkTtpCurrentStatus BITS
|
|
}
|
|
|
|
optIfODUkTtpTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable when optIfODUkDirectionality
|
|
has the value source(2) or bidirectional(3). It must not
|
|
be instantiated in rows where optIfODUkDirectionality
|
|
has the value sink(1).
|
|
If no value is ever set by a management entity for this
|
|
object, system-specific default value will be used.
|
|
Any implementation that instantiates this object must
|
|
document the system-specific default value or how it
|
|
is derived."
|
|
::= { optIfODUkTtpConfigEntry 1 }
|
|
|
|
optIfODUkTtpDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTtpConfigEntry 2 }
|
|
|
|
optIfODUkTtpSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTtpConfigEntry 3 }
|
|
|
|
optIfODUkTtpTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The value of this object is unspecified when
|
|
optIfODUkTtpCurrentStatus indicates a near-end defect
|
|
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
|
|
of the trace message."
|
|
::= { optIfODUkTtpConfigEntry 4 }
|
|
|
|
optIfODUkTtpTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is off(1)."
|
|
::= { optIfODUkTtpConfigEntry 5 }
|
|
|
|
optIfODUkTtpTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
This object has no effect when optIfODUkTtpTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfODUkTtpConfigEntry 6 }
|
|
|
|
optIfODUkTtpDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkDEGThr.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfODUkTtpConfigEntry 7 }
|
|
|
|
optIfODUkTtpDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2).
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfODUkTtpConfigEntry 8 }
|
|
|
|
optIfODUkTtpCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is only applicable to the sink function, i.e.,
|
|
only when optIfODUkDirectionality has the value sink(1)
|
|
or bidirectional(3). It must not be instantiated in rows
|
|
where optIfODUkDirectionality has the value source(2)."
|
|
::= { optIfODUkTtpConfigEntry 9 }
|
|
|
|
-- ODUk Position Sequence table
|
|
|
|
optIfODUkPositionSeqTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkPositionSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUk Position Sequence information."
|
|
::= { optIfODUk 3 }
|
|
|
|
optIfODUkPositionSeqEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkPositionSeqEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUk position sequence
|
|
information of an ODUk interface. The ODUk interface
|
|
is identified by the ifIndex. Associated with each
|
|
ODUk interface there may be one of more conceptual
|
|
rows in the optIfODUkPositionSeqTable. Each row
|
|
represents a TCM or GCC12 access function within the
|
|
associated ODUk interface. Rows of the
|
|
optIfODUkPositionSeqTable table are created/deleted
|
|
as the result of the creation/deletion of the optIfODUkT
|
|
or optIfGCC12 entities."
|
|
INDEX { ifIndex, optIfODUkPositionSeqIndex }
|
|
::= { optIfODUkPositionSeqTable 1 }
|
|
|
|
OptIfODUkPositionSeqEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkPositionSeqIndex Unsigned32,
|
|
optIfODUkPositionSeqPosition Unsigned32,
|
|
optIfODUkPositionSeqPointer RowPointer
|
|
}
|
|
|
|
optIfODUkPositionSeqIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies a row in the
|
|
optIfODUkPositionSeqTable Table.
|
|
Each row of the optIfODUkPositionSeqTable Table
|
|
represents a TCM or GCC12 access function within the
|
|
associated ODUk interface."
|
|
::= { optIfODUkPositionSeqEntry 1 }
|
|
|
|
optIfODUkPositionSeqPosition OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the position of the TCM or
|
|
GCC12 access function within the sequence of TCMs &
|
|
GCC12 access functions of the associated ODUk
|
|
interface. The TCM or GCC12 presented by this row is
|
|
referenced by the optIfODUkPositionSeqPointer variable."
|
|
::= { optIfODUkPositionSeqEntry 2 }
|
|
|
|
optIfODUkPositionSeqPointer OBJECT-TYPE
|
|
SYNTAX RowPointer
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the TCM or GCC12 access function
|
|
by pointing to the corresponding optIfODUkT or optIfGCC12
|
|
entity."
|
|
::= { optIfODUkPositionSeqEntry 3 }
|
|
|
|
-- ODUk Non-intrusive monitoring (Nim) config table
|
|
|
|
optIfODUkNimConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkNim configuration information."
|
|
::= { optIfODUk 4 }
|
|
|
|
optIfODUkNimConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkNim configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry
|
|
for which optIfODUkTtpPresent has the value false(2).
|
|
|
|
Instances of this conceptual row persist across
|
|
agent restarts, and read-create columns other
|
|
than the status column may be modified while the
|
|
row is active."
|
|
INDEX { ifIndex, optIfODUkNimDirectionality }
|
|
::= { optIfODUkNimConfigTable 1 }
|
|
|
|
OptIfODUkNimConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkNimDirectionality OptIfSinkOrSource,
|
|
optIfODUkNimDAPIExpected OptIfExDAPI,
|
|
optIfODUkNimSAPIExpected OptIfExSAPI,
|
|
optIfODUkNimTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkNimTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkNimTIMActEnabled TruthValue,
|
|
optIfODUkNimDEGThr OptIfDEGThr,
|
|
optIfODUkNimDEGM OptIfDEGM,
|
|
optIfODUkNimCurrentStatus BITS,
|
|
optIfODUkNimRowStatus RowStatus
|
|
}
|
|
|
|
optIfODUkNimDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfSinkOrSource
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the monitor point for the ODUk Path non-intrusive
|
|
monitoring function. The value source(2) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value sink(1), and the value sink(1) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value source(2). Either the value sink(1) or
|
|
source(2) is allowed if the corresponding instance of
|
|
optIfODUkDirectionality has the value bidirectional(3).
|
|
|
|
The value sink(1) means monitoring at the sink direction
|
|
path signal of the ODUk CTP.
|
|
|
|
The value source(2) means monitoring at the source direction
|
|
path signal of the ODUk CTP. Monitoring the source direction
|
|
of an ODUk CTP is necessary in those cases where the ODUk CTP
|
|
is at an SNCP (Subnetwork Connection Protection) end (e.g., see
|
|
Figure I.1.2/G.874.1). If one would like to get the performance
|
|
of the protected connection, one cannot use the NIM function
|
|
at both ODUk CTP sinks (before the matrix), instead one should
|
|
monitor the signal at the source ODUk CTP after the matrix."
|
|
::= { optIfODUkNimConfigEntry 1 }
|
|
|
|
optIfODUkNimDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object has no effect if optIfODUkNimTIMDetMode has
|
|
the value off(1) or sapi(3)."
|
|
::= { optIfODUkNimConfigEntry 2 }
|
|
|
|
optIfODUkNimSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object has no effect if optIfODUkNimTIMDetMode has
|
|
the value off(1) or dapi(2)."
|
|
::= { optIfODUkNimConfigEntry 3 }
|
|
|
|
optIfODUkNimTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted. The value of
|
|
this object is unspecified if optIfODUkNimCurrentStatus
|
|
has any of the bit positions oci(0), lck(1), or ssf(5)
|
|
set or if optIfODUkNimRowStatus has any value other
|
|
than active(1)."
|
|
::= { optIfODUkNimConfigEntry 4 }
|
|
|
|
optIfODUkNimTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
::= { optIfODUkNimConfigEntry 5 }
|
|
|
|
optIfODUkNimTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled."
|
|
::= { optIfODUkNimConfigEntry 6 }
|
|
|
|
optIfODUkNimDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad
|
|
if the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkNimDEGThr."
|
|
::= { optIfODUkNimConfigEntry 7 }
|
|
|
|
optIfODUkNimDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkNimDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
::= { optIfODUkNimConfigEntry 8 }
|
|
|
|
optIfODUkNimCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if
|
|
any. The value of this object is unspecified if
|
|
optIfODUkNimRowStatus has any value other than
|
|
active(1)."
|
|
::= { optIfODUkNimConfigEntry 9 }
|
|
|
|
optIfODUkNimRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting
|
|
a conceptual row of the optIfODUkNim config table.
|
|
It is used to model the activateNim and deactivateNim
|
|
operations of an OTUk_CTP for non-intrusive monitoring
|
|
control as defined in G.874.1. Setting RowStatus to
|
|
createAndGo or createAndWait implies activateNim.
|
|
Setting RowStatus to destroy implies deactivateNim."
|
|
::= { optIfODUkNimConfigEntry 10 }
|
|
|
|
-- GCC12 config table
|
|
|
|
optIfGCC12ConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfGCC12ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of GCC12 configuration information.
|
|
The GCC function processes the GCC overhead bytes passing
|
|
through them but leave the remainder of the ODUk overhead
|
|
and payload data alone."
|
|
::= { optIfODUk 5 }
|
|
|
|
optIfGCC12ConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfGCC12ConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains GCC12 configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Separate instances providing GCC1-only access and
|
|
GCC2-only access may exist for a given ifIndex value,
|
|
or a single instance providing GCC1 + GCC2 may exist,
|
|
but a GCC1 + GCC2 instance may not coexist with a
|
|
GCC1-only or GCC2-only instance.
|
|
|
|
Instances of this conceptual row persist across agent
|
|
restarts."
|
|
INDEX { ifIndex, optIfGCC12Codirectional, optIfGCC12GCCAccess }
|
|
::= { optIfGCC12ConfigTable 1 }
|
|
|
|
|
|
OptIfGCC12ConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfGCC12Codirectional TruthValue,
|
|
optIfGCC12GCCAccess INTEGER,
|
|
optIfGCC12GCCPassThrough TruthValue,
|
|
optIfGCC12Application SnmpAdminString,
|
|
optIfGCC12RowStatus RowStatus
|
|
}
|
|
|
|
optIfGCC12Codirectional OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the GCC12 termination with
|
|
respect to the associated ODUk CTP. The value true(1) means
|
|
that the sink part of the GCC12 extracts COMMS data from the
|
|
signal at the input to the ODUk CTP sink and the source part
|
|
of the GCC12 inserts COMMS data into the signal at the output
|
|
of the ODUk CTP source. The value false(2) means that the
|
|
sink part of the GCC12 extracts COMMS data from the signal at
|
|
the output of the ODUk CTP source and the source part of the
|
|
GCC12 inserts COMMS data into the signal at the input of the
|
|
ODUk CTP sink. This attribute may assume either value when
|
|
the corresponding instance of optIfODUkTtpPresent has the
|
|
value false(2). When the value of the corresponding instance
|
|
of optIfODUkTtpPresent is true(1) then the only value allowed
|
|
for this attribute is true(1)."
|
|
::= { optIfGCC12ConfigEntry 1 }
|
|
|
|
optIfGCC12GCCAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gcc1 (1),
|
|
gcc2 (2),
|
|
gcc1and2 (3)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the GCC access represented by the entity."
|
|
::= { optIfGCC12ConfigEntry 2 }
|
|
|
|
optIfGCC12GCCPassThrough OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the selected GCC overhead bytes are passed
|
|
through or modified. The value true(1) means that the selected
|
|
GCC overhead bytes are passed through unmodified from the ODUk
|
|
CTP input to the ODUk CTP output. The value false(2) means that
|
|
the selected GCC overhead bytes are set to zero at the ODUk CTP
|
|
output after the extraction of the COMMS data. This object has
|
|
no effect if the corresponding instance of optIfODUkTtpPresent
|
|
has the value true(1).
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC12RowStatus has the value active(1)."
|
|
::= { optIfGCC12ConfigEntry 3 }
|
|
|
|
optIfGCC12Application OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the application transported by the GCC12 entity.
|
|
Example applications are ECC, User data channel.
|
|
|
|
The value of this object may not be changed when
|
|
optIfGCC12RowStatus has the value active(1)."
|
|
::= { optIfGCC12ConfigEntry 4 }
|
|
|
|
optIfGCC12RowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting
|
|
a conceptual row of the optIfGCC12 config table. It is
|
|
used to model the addGCC12Access and removeGCC12Access
|
|
operations of an ODUk_CTP or ODUk_TTP for GCC12 access
|
|
control as defined in G.874.1. Setting RowStatus to
|
|
createAndGo or createAndWait implies addGCC12Access.
|
|
Setting RowStatus to destroy implies removeGCC12Access.
|
|
Successful addition/removal of the GCC12 access function
|
|
will result in updating the
|
|
optIfODUkPositionSeqCurrentSize variable and the
|
|
optIfODUkPositionSeqTable table of the associated
|
|
ODUk entry in the optIfODUkConfigTable."
|
|
::= { optIfGCC12ConfigEntry 5 }
|
|
|
|
-- the optIfODUkT group
|
|
-- This group handles the configuration information
|
|
-- for the ODUkT layers.
|
|
|
|
-- ODUkT config table
|
|
|
|
optIfODUkTConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkT configuration information."
|
|
::= { optIfODUkT 1 }
|
|
|
|
optIfODUkTConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkT configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Rows in this table are mutually exclusive with rows
|
|
in the ODUkT NIM config table -- in other words, this
|
|
row object may not be instantiated for a given pair
|
|
of ifIndex and TCM field values if a corresponding
|
|
instance of optIfODUkTNimConfigEntry already exists.
|
|
|
|
Instances of this conceptual row persist across agent
|
|
restarts. Except where noted otherwise, read-create
|
|
columns other than the status column may be modified
|
|
while the row is active."
|
|
INDEX { ifIndex, optIfODUkTTcmField, optIfODUkTCodirectional }
|
|
::= { optIfODUkTConfigTable 1 }
|
|
|
|
OptIfODUkTConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTTcmField Unsigned32,
|
|
optIfODUkTCodirectional TruthValue,
|
|
optIfODUkTTraceIdentifierTransmitted OptIfTxTI,
|
|
optIfODUkTDAPIExpected OptIfExDAPI,
|
|
optIfODUkTSAPIExpected OptIfExSAPI,
|
|
optIfODUkTTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTTIMActEnabled TruthValue,
|
|
optIfODUkTDEGThr OptIfDEGThr,
|
|
optIfODUkTDEGM OptIfDEGM,
|
|
optIfODUkTSinkMode INTEGER,
|
|
optIfODUkTSinkLockSignalAdminState INTEGER,
|
|
optIfODUkTSourceLockSignalAdminState INTEGER,
|
|
optIfODUkTCurrentStatus BITS,
|
|
optIfODUkTRowStatus RowStatus
|
|
}
|
|
|
|
|
|
optIfODUkTTcmField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..6)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the tandem connection monitoring
|
|
field of the ODUk OH. Valid values are
|
|
integers from 1 to 6."
|
|
::= { optIfODUkTConfigEntry 1 }
|
|
|
|
optIfODUkTCodirectional OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the directionality of the ODUkT termination point with
|
|
respect to the associated ODUk CTP. The value true(1) means
|
|
that the sink part of the ODUkT TP extracts TCM data from the
|
|
signal at the input to the ODUk CTP sink and the source part
|
|
of the ODUkT TP inserts TCM data into the signal at the output
|
|
of the ODUk CTP source. The value false(2) means that the
|
|
sink part of the ODUkT TP extracts TCM data from the signal at
|
|
the output of the ODUk CTP source and the source part of the
|
|
ODUkT TP inserts TCM data into the signal at the input of the
|
|
ODUk CTP sink. This attribute may assume either value when
|
|
the corresponding instance of optIfODUkTtpPresent has the
|
|
value false(2). When the value of the corresponding instance
|
|
of optIfODUkTtpPresent is true(1) then the only value allowed
|
|
for this attribute is true(1)."
|
|
::= { optIfODUkTConfigEntry 2 }
|
|
|
|
optIfODUkTTraceIdentifierTransmitted OBJECT-TYPE
|
|
SYNTAX OptIfTxTI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trace identifier transmitted.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value false(2), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value true(1).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 3 }
|
|
|
|
optIfODUkTDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTConfigEntry 4 }
|
|
|
|
optIfODUkTSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1)."
|
|
::= { optIfODUkTConfigEntry 5 }
|
|
|
|
optIfODUkTTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The value of this object is unspecified when
|
|
optIfODUkTCurrentStatus indicates a near-end defect
|
|
(i.e., oci(0), lck(1), ssf(5)) that prevents extraction
|
|
of the trace message."
|
|
::= { optIfODUkTConfigEntry 6 }
|
|
|
|
optIfODUkTTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is off(1)."
|
|
::= { optIfODUkTConfigEntry 7 }
|
|
|
|
optIfODUkTTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
This object has no effect when optIfODUkTTIMDetMode has
|
|
the value off(1).
|
|
The default value of this object is false(2)."
|
|
::= { optIfODUkTConfigEntry 8 }
|
|
|
|
optIfODUkTDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkTDEGThr.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is Severely Errored Second
|
|
(SES) Estimator (See ITU-T G.7710)."
|
|
::= { optIfODUkTConfigEntry 9 }
|
|
|
|
optIfODUkTDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkTDEGM
|
|
consecutive bad PM Seconds are detected.
|
|
This object is applicable only to the following three cases.
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases.
|
|
The default value of this object is 7 (See ITU-T G.7710)."
|
|
::= { optIfODUkTConfigEntry 10 }
|
|
|
|
optIfODUkTSinkMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
operational (1),
|
|
monitor (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the TCM mode at the entity.
|
|
The value operational(1) means that TCM Overhead (TCMOH)
|
|
processes (see ITU-T G.798) shall be
|
|
performed and consequent actions for AIS, Trail
|
|
Signal Fail (TSF), Trail Signal Degraded (TSD) shall be
|
|
initiated in case of defects.
|
|
The value monitor(2) means that TCMOH processes shall be
|
|
performed but consequent actions for AIS, Trail
|
|
Server Failure (TSF), Trail Server Degraded (TSD) shall _not_ be
|
|
initiated in case of defects.
|
|
This object is applicable only when the value of
|
|
optIfODUkTtpPresent is false(2) and also either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 11 }
|
|
|
|
optIfODUkTSinkLockSignalAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the capability to provision the LOCK signal, which
|
|
is one of the ODUk maintenance signals, at the ODUKT sink. When
|
|
a Tandem Connection endpoint is set to admin state locked,
|
|
it inserts the ODUk-LCK signal in the sink direction.
|
|
|
|
This object is applicable only when the value of
|
|
optIfODUkTtpPresent is false(2) and also either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 12 }
|
|
|
|
optIfODUkTSourceLockSignalAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(1),
|
|
normal(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides the capability to provision the LOCK signal, which
|
|
is one of the ODUk maintenance signals, at the source.
|
|
When a Tandem Connection endpoint is set to admin state
|
|
locked, it inserts the ODUk-LCK signal in the source
|
|
direction.
|
|
This object is applicable only when either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value false(2), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value true(1).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 13 }
|
|
|
|
optIfODUkTCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
This object is applicable only when either one of the
|
|
following three cases holds:
|
|
(i) optIfODUkDirectionality has the value bidirectional(3), or
|
|
(ii) optIfODUkDirectionality has the value sink(1) and
|
|
optIfODUkTCodirectional has the value true(1), or
|
|
(iii) optIfODUkDirectionality has the value source(3) and
|
|
optIfODUkTCodirectional has the value false(2).
|
|
It must not be instantiated in rows for all other cases."
|
|
::= { optIfODUkTConfigEntry 14 }
|
|
|
|
optIfODUkTRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfODUkT config table.
|
|
It is used to model the addTCM and removeTCM operations of an
|
|
ODUk_CTP or ODUk_TTP for Tandem connection monitoring as defined
|
|
in ITU-T G.874.1.
|
|
Setting RowStatus to createAndGo or createAndWait implies addTCM.
|
|
Setting RowStatus to destroy implies removeTCM.
|
|
Successful addition/removal of TCM will result in updating the
|
|
optIfODUkTcmFieldsInUse and optIfODUkPositionSeqCurrentSize
|
|
variables and the optIfODUkPositionSeqTable table of the
|
|
associated ODUk entry in the optIfODUkConfigTable."
|
|
::= { optIfODUkTConfigEntry 15 }
|
|
|
|
-- ODUkT Non-intrusive monitoring (Nim) config table
|
|
|
|
optIfODUkTNimConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OptIfODUkTNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of ODUkTNim configuration information."
|
|
::= { optIfODUkT 2 }
|
|
|
|
optIfODUkTNimConfigEntry OBJECT-TYPE
|
|
SYNTAX OptIfODUkTNimConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row that contains ODUkTNim configuration
|
|
information of an interface. Each instance must
|
|
correspond to an instance of optIfODUkConfigEntry.
|
|
Rows in this table are mutually exclusive with rows
|
|
in the ODUkT config table -- in other words, this
|
|
row object may not be instantiated for a given pair
|
|
of ifIndex and TCM field values if a corresponding
|
|
instance of optIfODUkTConfigEntry already exists.
|
|
|
|
Instances of this conceptual row persist across
|
|
agent restarts, and read-create columns other
|
|
than the status column may be modified while the
|
|
row is active."
|
|
INDEX {ifIndex, optIfODUkTNimTcmField, optIfODUkTNimDirectionality}
|
|
::= { optIfODUkTNimConfigTable 1 }
|
|
|
|
OptIfODUkTNimConfigEntry ::=
|
|
SEQUENCE {
|
|
optIfODUkTNimTcmField Unsigned32,
|
|
optIfODUkTNimDirectionality OptIfSinkOrSource,
|
|
optIfODUkTNimDAPIExpected OptIfExDAPI,
|
|
optIfODUkTNimSAPIExpected OptIfExSAPI,
|
|
optIfODUkTNimTraceIdentifierAccepted OptIfAcTI,
|
|
optIfODUkTNimTIMDetMode OptIfTIMDetMode,
|
|
optIfODUkTNimTIMActEnabled TruthValue,
|
|
optIfODUkTNimDEGThr OptIfDEGThr,
|
|
optIfODUkTNimDEGM OptIfDEGM,
|
|
optIfODUkTNimCurrentStatus BITS,
|
|
optIfODUkTNimRowStatus RowStatus
|
|
}
|
|
|
|
optIfODUkTNimTcmField OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..6)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the tandem connection monitoring
|
|
field of the ODUk OH on which non-intrusive monitoring
|
|
is performed. Valid values are
|
|
integers from 1 to 6."
|
|
::= { optIfODUkTNimConfigEntry 1 }
|
|
|
|
optIfODUkTNimDirectionality OBJECT-TYPE
|
|
SYNTAX OptIfSinkOrSource
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the monitor point for the ODUk TCM non-intrusive
|
|
monitoring function. The value source(2) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value sink(1), and the value sink(1) is not allowed
|
|
if the corresponding instance of optIfODUkDirectionality
|
|
has the value source(2). Either the value sink(1) or
|
|
source(2) is allowed if the corresponding instance of
|
|
optIfODUkDirectionality has the value bidirectional(3).
|
|
The value sink(1) means monitoring at the sink direction
|
|
TCM signal of the ODUk CTP.
|
|
The value source(2) means monitoring at the source direction
|
|
path signal of the ODUk CTP."
|
|
::= { optIfODUkTNimConfigEntry 2 }
|
|
|
|
optIfODUkTNimDAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExDAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DAPI expected by the receiver.
|
|
This object has no effect if optIfODUkTNimTIMDetMode has
|
|
the value off(1) or sapi(3)."
|
|
::= { optIfODUkTNimConfigEntry 3 }
|
|
|
|
optIfODUkTNimSAPIExpected OBJECT-TYPE
|
|
SYNTAX OptIfExSAPI
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SAPI expected by the receiver.
|
|
This object has no effect if optIfODUkTNimTIMDetMode has
|
|
the value off(1) or dapi(2)."
|
|
|
|
::= { optIfODUkTNimConfigEntry 4 }
|
|
|
|
optIfODUkTNimTraceIdentifierAccepted OBJECT-TYPE
|
|
SYNTAX OptIfAcTI
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The actual trace identifier accepted. The value of
|
|
this object is unspecified if optIfODUkTNimCurrentStatus
|
|
has any of the bit positions oci(0), lck(1), or ssf(5)
|
|
set or if optIfODUkTNimRowStatus has any value other
|
|
than active(1)."
|
|
::= { optIfODUkTNimConfigEntry 5 }
|
|
|
|
optIfODUkTNimTIMDetMode OBJECT-TYPE
|
|
SYNTAX OptIfTIMDetMode
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the mode of the Trace Identifier Mismatch (TIM)
|
|
Detection function."
|
|
::= { optIfODUkTNimConfigEntry 6 }
|
|
|
|
optIfODUkTNimTIMActEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the Trace Identifier Mismatch (TIM)
|
|
Consequent Action function is enabled."
|
|
::= { optIfODUkTNimConfigEntry 7 }
|
|
|
|
optIfODUkTNimDEGThr OBJECT-TYPE
|
|
SYNTAX OptIfDEGThr
|
|
UNITS "percentage"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a performance
|
|
monitoring (PM) Second to be bad. A PM Second is declared bad if
|
|
the percentage of detected errored blocks in that second is
|
|
greater than or equal to optIfODUkTNimDEGThr."
|
|
::= { optIfODUkTNimConfigEntry 8 }
|
|
|
|
optIfODUkTNimDEGM OBJECT-TYPE
|
|
SYNTAX OptIfDEGM
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the threshold level for declaring a Degraded Signal
|
|
defect (dDEG). A dDEG shall be declared if optIfODUkTNimDEGM
|
|
consecutive bad PM Seconds are detected."
|
|
::= { optIfODUkTNimConfigEntry 9 }
|
|
|
|
optIfODUkTNimCurrentStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
oci(0),
|
|
lck(1),
|
|
tim(2),
|
|
deg(3),
|
|
bdi(4),
|
|
ssf(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the defect condition of the entity, if any.
|
|
The value of this object is unspecified if
|
|
optIfODUkTNimRowStatus has any value other than
|
|
active(1)."
|
|
::= { optIfODUkTNimConfigEntry 10 }
|
|
|
|
optIfODUkTNimRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This columnar object is used for creating and deleting a
|
|
conceptual row of the optIfODUkTNim config table.
|
|
It is used to model the addTCM and removeTCM operations of an
|
|
ODUk_CTP or ODUk_TTP for non-intrusive Tandem connection
|
|
monitoring as defined in ITU-T G.874.1.
|
|
Setting RowStatus to createAndGo or createAndWait implies addTCM.
|
|
Setting RowStatus to destroy implies removeTCM.
|
|
Successful addition/removal of Nim TCM will result in updating
|
|
the optIfODUkPositionSeqCurrentSize variable and the
|
|
optIfODUkPositionSeqTable table of the associated ODUk entry
|
|
in the optIfODUkConfigTable."
|
|
::= { optIfODUkTNimConfigEntry 11 }
|
|
|
|
-- units of conformance
|
|
|
|
optIfOTMnGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTMnOrder,
|
|
optIfOTMnReduced,
|
|
optIfOTMnBitRates,
|
|
optIfOTMnInterfaceType,
|
|
optIfOTMnTcmMax,
|
|
optIfOTMnOpticalReach
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of OTMn structure information objects."
|
|
::= { optIfGroups 1 }
|
|
|
|
optIfPerfMonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfPerfMonCurrentTimeElapsed,
|
|
optIfPerfMonCurDayTimeElapsed,
|
|
optIfPerfMonIntervalNumIntervals,
|
|
optIfPerfMonIntervalNumInvalidIntervals
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of performance monitoring interval objects."
|
|
::= { optIfGroups 2 }
|
|
|
|
optIfOTSnCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTSn interfaces."
|
|
::= { optIfGroups 3 }
|
|
|
|
optIfOTSnSourceGroupFull OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnTraceIdentifierTransmitted
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to full-functionality/IaDI OTSn
|
|
interfaces that support source functions."
|
|
::= { optIfGroups 4 }
|
|
|
|
optIfOTSnAPRStatusGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnAprStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects applicable to
|
|
OTSn interfaces that support Automatic
|
|
Power Reduction functions."
|
|
::= { optIfGroups 5 }
|
|
|
|
optIfOTSnAPRControlGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnAprControl
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects applicable to
|
|
OTSn interfaces that provide Automatic
|
|
Power Reduction control functions."
|
|
::= { optIfGroups 6 }
|
|
|
|
optIfOTSnSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 7 }
|
|
|
|
optIfOTSnSinkGroupFull OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnDAPIExpected,
|
|
optIfOTSnSAPIExpected,
|
|
optIfOTSnTraceIdentifierAccepted,
|
|
optIfOTSnTIMDetMode,
|
|
optIfOTSnTIMActEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to full-functionality/IaDI OTSn
|
|
interfaces that support sink functions."
|
|
::= { optIfGroups 8 }
|
|
|
|
optIfOTSnSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSinkCurrentSuspectedFlag,
|
|
optIfOTSnSinkCurrentInputPower,
|
|
optIfOTSnSinkCurrentLowInputPower,
|
|
optIfOTSnSinkCurrentHighInputPower,
|
|
optIfOTSnSinkCurrentOutputPower,
|
|
optIfOTSnSinkCurrentLowOutputPower,
|
|
optIfOTSnSinkCurrentHighOutputPower,
|
|
optIfOTSnSinkIntervalSuspectedFlag,
|
|
optIfOTSnSinkIntervalLastInputPower,
|
|
optIfOTSnSinkIntervalLowInputPower,
|
|
optIfOTSnSinkIntervalHighInputPower,
|
|
optIfOTSnSinkIntervalLastOutputPower,
|
|
optIfOTSnSinkIntervalLowOutputPower,
|
|
optIfOTSnSinkIntervalHighOutputPower,
|
|
optIfOTSnSinkCurDaySuspectedFlag,
|
|
optIfOTSnSinkCurDayLowInputPower,
|
|
optIfOTSnSinkCurDayHighInputPower,
|
|
optIfOTSnSinkCurDayLowOutputPower,
|
|
optIfOTSnSinkCurDayHighOutputPower,
|
|
optIfOTSnSinkPrevDaySuspectedFlag,
|
|
optIfOTSnSinkPrevDayLastInputPower,
|
|
optIfOTSnSinkPrevDayLowInputPower,
|
|
optIfOTSnSinkPrevDayHighInputPower,
|
|
optIfOTSnSinkPrevDayLastOutputPower,
|
|
optIfOTSnSinkPrevDayLowOutputPower,
|
|
optIfOTSnSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OTSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 9 }
|
|
|
|
optIfOTSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSinkCurrentLowerInputPowerThreshold,
|
|
optIfOTSnSinkCurrentUpperInputPowerThreshold,
|
|
optIfOTSnSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOTSnSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OTSn interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 10 }
|
|
|
|
optIfOTSnSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSrcCurrentSuspectedFlag,
|
|
optIfOTSnSrcCurrentOutputPower,
|
|
optIfOTSnSrcCurrentLowOutputPower,
|
|
optIfOTSnSrcCurrentHighOutputPower,
|
|
optIfOTSnSrcCurrentInputPower,
|
|
optIfOTSnSrcCurrentLowInputPower,
|
|
optIfOTSnSrcCurrentHighInputPower,
|
|
optIfOTSnSrcIntervalSuspectedFlag,
|
|
optIfOTSnSrcIntervalLastOutputPower,
|
|
optIfOTSnSrcIntervalLowOutputPower,
|
|
optIfOTSnSrcIntervalHighOutputPower,
|
|
optIfOTSnSrcIntervalLastInputPower,
|
|
optIfOTSnSrcIntervalLowInputPower,
|
|
optIfOTSnSrcIntervalHighInputPower,
|
|
optIfOTSnSrcCurDaySuspectedFlag,
|
|
optIfOTSnSrcCurDayLowOutputPower,
|
|
optIfOTSnSrcCurDayHighOutputPower,
|
|
optIfOTSnSrcCurDayLowInputPower,
|
|
optIfOTSnSrcCurDayHighInputPower,
|
|
optIfOTSnSrcPrevDaySuspectedFlag,
|
|
optIfOTSnSrcPrevDayLastOutputPower,
|
|
optIfOTSnSrcPrevDayLowOutputPower,
|
|
optIfOTSnSrcPrevDayHighOutputPower,
|
|
optIfOTSnSrcPrevDayLastInputPower,
|
|
optIfOTSnSrcPrevDayLowInputPower,
|
|
optIfOTSnSrcPrevDayHighInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OTSn interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 11 }
|
|
|
|
optIfOTSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTSnSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOTSnSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOTSnSrcCurrentLowerInputPowerThreshold,
|
|
optIfOTSnSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OTSn interfaces
|
|
that support source functions."
|
|
::= { optIfGroups 12 }
|
|
|
|
optIfOMSnCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OMSn interfaces."
|
|
::= { optIfGroups 13 }
|
|
|
|
optIfOMSnSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OMSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 14 }
|
|
|
|
optIfOMSnSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSinkCurrentSuspectedFlag,
|
|
optIfOMSnSinkCurrentAggregatedInputPower,
|
|
optIfOMSnSinkCurrentLowAggregatedInputPower,
|
|
optIfOMSnSinkCurrentHighAggregatedInputPower,
|
|
optIfOMSnSinkCurrentOutputPower,
|
|
optIfOMSnSinkCurrentLowOutputPower,
|
|
optIfOMSnSinkCurrentHighOutputPower,
|
|
optIfOMSnSinkIntervalSuspectedFlag,
|
|
optIfOMSnSinkIntervalLastAggregatedInputPower,
|
|
optIfOMSnSinkIntervalLowAggregatedInputPower,
|
|
optIfOMSnSinkIntervalHighAggregatedInputPower,
|
|
optIfOMSnSinkIntervalLastOutputPower,
|
|
optIfOMSnSinkIntervalLowOutputPower,
|
|
optIfOMSnSinkIntervalHighOutputPower,
|
|
optIfOMSnSinkCurDaySuspectedFlag,
|
|
optIfOMSnSinkCurDayLowAggregatedInputPower,
|
|
optIfOMSnSinkCurDayHighAggregatedInputPower,
|
|
optIfOMSnSinkCurDayLowOutputPower,
|
|
optIfOMSnSinkCurDayHighOutputPower,
|
|
optIfOMSnSinkPrevDaySuspectedFlag,
|
|
optIfOMSnSinkPrevDayLastAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayLowAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayHighAggregatedInputPower,
|
|
optIfOMSnSinkPrevDayLastOutputPower,
|
|
optIfOMSnSinkPrevDayLowOutputPower,
|
|
optIfOMSnSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OMSn interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 15 }
|
|
|
|
optIfOMSnSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSinkCurrentLowerInputPowerThreshold,
|
|
optIfOMSnSinkCurrentUpperInputPowerThreshold,
|
|
optIfOMSnSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOMSnSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OMSn interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 16 }
|
|
|
|
optIfOMSnSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSrcCurrentSuspectedFlag,
|
|
optIfOMSnSrcCurrentOutputPower,
|
|
optIfOMSnSrcCurrentLowOutputPower,
|
|
optIfOMSnSrcCurrentHighOutputPower,
|
|
optIfOMSnSrcCurrentAggregatedInputPower,
|
|
optIfOMSnSrcCurrentLowAggregatedInputPower,
|
|
optIfOMSnSrcCurrentHighAggregatedInputPower,
|
|
optIfOMSnSrcIntervalSuspectedFlag,
|
|
optIfOMSnSrcIntervalLastOutputPower,
|
|
optIfOMSnSrcIntervalLowOutputPower,
|
|
optIfOMSnSrcIntervalHighOutputPower,
|
|
optIfOMSnSrcIntervalLastAggregatedInputPower,
|
|
optIfOMSnSrcIntervalLowAggregatedInputPower,
|
|
optIfOMSnSrcIntervalHighAggregatedInputPower,
|
|
optIfOMSnSrcCurDaySuspectedFlag,
|
|
optIfOMSnSrcCurDayLowOutputPower,
|
|
optIfOMSnSrcCurDayHighOutputPower,
|
|
optIfOMSnSrcCurDayLowAggregatedInputPower,
|
|
optIfOMSnSrcCurDayHighAggregatedInputPower,
|
|
optIfOMSnSrcPrevDaySuspectedFlag,
|
|
optIfOMSnSrcPrevDayLastOutputPower,
|
|
optIfOMSnSrcPrevDayLowOutputPower,
|
|
optIfOMSnSrcPrevDayHighOutputPower,
|
|
optIfOMSnSrcPrevDayLastAggregatedInputPower,
|
|
optIfOMSnSrcPrevDayLowAggregatedInputPower,
|
|
optIfOMSnSrcPrevDayHighAggregatedInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OMSn interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 17 }
|
|
|
|
optIfOMSnSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOMSnSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOMSnSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOMSnSrcCurrentLowerInputPowerThreshold,
|
|
optIfOMSnSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OMSn interfaces that
|
|
that support source functions."
|
|
::= { optIfGroups 18 }
|
|
|
|
optIfOChGroupCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OChGroup interfaces."
|
|
::= { optIfGroups 19 }
|
|
|
|
optIfOChGroupSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSinkCurrentSuspectedFlag,
|
|
optIfOChGroupSinkCurrentAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentLowAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentHighAggregatedInputPower,
|
|
optIfOChGroupSinkCurrentOutputPower,
|
|
optIfOChGroupSinkCurrentLowOutputPower,
|
|
optIfOChGroupSinkCurrentHighOutputPower,
|
|
optIfOChGroupSinkIntervalSuspectedFlag,
|
|
optIfOChGroupSinkIntervalLastAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalLowAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalHighAggregatedInputPower,
|
|
optIfOChGroupSinkIntervalLastOutputPower,
|
|
optIfOChGroupSinkIntervalLowOutputPower,
|
|
optIfOChGroupSinkIntervalHighOutputPower,
|
|
optIfOChGroupSinkCurDaySuspectedFlag,
|
|
optIfOChGroupSinkCurDayLowAggregatedInputPower,
|
|
optIfOChGroupSinkCurDayHighAggregatedInputPower,
|
|
optIfOChGroupSinkCurDayLowOutputPower,
|
|
optIfOChGroupSinkCurDayHighOutputPower,
|
|
optIfOChGroupSinkPrevDaySuspectedFlag,
|
|
optIfOChGroupSinkPrevDayLastAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayLowAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayHighAggregatedInputPower,
|
|
optIfOChGroupSinkPrevDayLastOutputPower,
|
|
optIfOChGroupSinkPrevDayLowOutputPower,
|
|
optIfOChGroupSinkPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OChGroup interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 20 }
|
|
|
|
optIfOChGroupSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSinkCurrentLowerInputPowerThreshold,
|
|
optIfOChGroupSinkCurrentUpperInputPowerThreshold,
|
|
optIfOChGroupSinkCurrentLowerOutputPowerThreshold,
|
|
optIfOChGroupSinkCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OChGroup interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 21 }
|
|
|
|
optIfOChGroupSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSrcCurrentSuspectedFlag,
|
|
optIfOChGroupSrcCurrentOutputPower,
|
|
optIfOChGroupSrcCurrentLowOutputPower,
|
|
optIfOChGroupSrcCurrentHighOutputPower,
|
|
optIfOChGroupSrcCurrentAggregatedInputPower,
|
|
optIfOChGroupSrcCurrentLowAggregatedInputPower,
|
|
optIfOChGroupSrcCurrentHighAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalSuspectedFlag,
|
|
optIfOChGroupSrcIntervalLastOutputPower,
|
|
optIfOChGroupSrcIntervalLowOutputPower,
|
|
optIfOChGroupSrcIntervalHighOutputPower,
|
|
optIfOChGroupSrcIntervalLastAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalLowAggregatedInputPower,
|
|
optIfOChGroupSrcIntervalHighAggregatedInputPower,
|
|
optIfOChGroupSrcCurDaySuspectedFlag,
|
|
optIfOChGroupSrcCurDayLowOutputPower,
|
|
optIfOChGroupSrcCurDayHighOutputPower,
|
|
optIfOChGroupSrcCurDayLowAggregatedInputPower,
|
|
optIfOChGroupSrcCurDayHighAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDaySuspectedFlag,
|
|
optIfOChGroupSrcPrevDayLastOutputPower,
|
|
optIfOChGroupSrcPrevDayLowOutputPower,
|
|
optIfOChGroupSrcPrevDayHighOutputPower,
|
|
optIfOChGroupSrcPrevDayLastAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDayLowAggregatedInputPower,
|
|
optIfOChGroupSrcPrevDayHighAggregatedInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OChGroup interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 22 }
|
|
|
|
optIfOChGroupSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChGroupSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOChGroupSrcCurrentUpperOutputPowerThreshold,
|
|
optIfOChGroupSrcCurrentLowerInputPowerThreshold,
|
|
optIfOChGroupSrcCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OChGroup interfaces that
|
|
that support source functions."
|
|
::= { optIfGroups 23 }
|
|
|
|
optIfOChCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChDirectionality
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OCh interfaces."
|
|
::= { optIfGroups 24 }
|
|
|
|
optIfOChSinkGroupBasic OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OCh interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 25 }
|
|
|
|
optIfOChSinkPreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSinkCurrentSuspectedFlag,
|
|
optIfOChSinkCurrentInputPower,
|
|
optIfOChSinkCurrentLowInputPower,
|
|
optIfOChSinkCurrentHighInputPower,
|
|
optIfOChSinkIntervalSuspectedFlag,
|
|
optIfOChSinkIntervalLastInputPower,
|
|
optIfOChSinkIntervalLowInputPower,
|
|
optIfOChSinkIntervalHighInputPower,
|
|
optIfOChSinkCurDaySuspectedFlag,
|
|
optIfOChSinkCurDayLowInputPower,
|
|
optIfOChSinkCurDayHighInputPower,
|
|
optIfOChSinkPrevDaySuspectedFlag,
|
|
optIfOChSinkPrevDayLastInputPower,
|
|
optIfOChSinkPrevDayLowInputPower,
|
|
optIfOChSinkPrevDayHighInputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OCh interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 26 }
|
|
|
|
optIfOChSinkPreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSinkCurrentLowerInputPowerThreshold,
|
|
optIfOChSinkCurrentUpperInputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OCh interfaces
|
|
that support sink functions."
|
|
::= { optIfGroups 27 }
|
|
|
|
|
|
optIfOChSourcePreOtnPMGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSrcCurrentSuspectedFlag,
|
|
optIfOChSrcCurrentOutputPower,
|
|
optIfOChSrcCurrentLowOutputPower,
|
|
optIfOChSrcCurrentHighOutputPower,
|
|
optIfOChSrcIntervalSuspectedFlag,
|
|
optIfOChSrcIntervalLastOutputPower,
|
|
optIfOChSrcIntervalLowOutputPower,
|
|
optIfOChSrcIntervalHighOutputPower,
|
|
optIfOChSrcCurDaySuspectedFlag,
|
|
optIfOChSrcCurDayLowOutputPower,
|
|
optIfOChSrcCurDayHighOutputPower,
|
|
optIfOChSrcPrevDaySuspectedFlag,
|
|
optIfOChSrcPrevDayLastOutputPower,
|
|
optIfOChSrcPrevDayLowOutputPower,
|
|
optIfOChSrcPrevDayHighOutputPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
objects applicable to OCh interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 28 }
|
|
|
|
optIfOChSourcePreOtnPMThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOChSrcCurrentLowerOutputPowerThreshold,
|
|
optIfOChSrcCurrentUpperOutputPowerThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of pre-OTN performance monitoring
|
|
threshold objects applicable to OCh interfaces
|
|
that support source functions."
|
|
::= { optIfGroups 29 }
|
|
|
|
optIfOTUkCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkDirectionality,
|
|
optIfOTUkBitRateK
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all OTUk interfaces."
|
|
::= { optIfGroups 30 }
|
|
|
|
optIfOTUkSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkTraceIdentifierTransmitted,
|
|
optIfOTUkSourceAdaptActive
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to OTUk interfaces that
|
|
support source functions."
|
|
::= { optIfGroups 31 }
|
|
|
|
optIfOTUkSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfOTUkDAPIExpected,
|
|
optIfOTUkSAPIExpected,
|
|
optIfOTUkTraceIdentifierAccepted,
|
|
optIfOTUkTIMDetMode,
|
|
optIfOTUkTIMActEnabled,
|
|
optIfOTUkDEGThr,
|
|
optIfOTUkDEGM,
|
|
optIfOTUkSinkAdaptActive,
|
|
optIfOTUkSinkFECEnabled,
|
|
optIfOTUkCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to OTUk interfaces that
|
|
support sink functions."
|
|
::= { optIfGroups 32 }
|
|
|
|
optIfGCC0Group OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfGCC0Application,
|
|
optIfGCC0RowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of GCC0 configuration objects."
|
|
::= { optIfGroups 33 }
|
|
|
|
optIfODUkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkDirectionality,
|
|
optIfODUkBitRateK,
|
|
optIfODUkTcmFieldsInUse,
|
|
optIfODUkPositionSeqCurrentSize,
|
|
optIfODUkPositionSeqPosition,
|
|
optIfODUkPositionSeqPointer,
|
|
optIfODUkTtpPresent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUk interfaces."
|
|
::= { optIfGroups 34 }
|
|
|
|
optIfODUkTtpSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTtpTraceIdentifierTransmitted
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all interfaces that support
|
|
ODUk trail termination source functions."
|
|
::= { optIfGroups 35 }
|
|
|
|
optIfODUkTtpSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTtpDAPIExpected,
|
|
optIfODUkTtpSAPIExpected,
|
|
optIfODUkTtpTraceIdentifierAccepted,
|
|
optIfODUkTtpTIMDetMode,
|
|
optIfODUkTtpTIMActEnabled,
|
|
optIfODUkTtpDEGThr,
|
|
optIfODUkTtpDEGM,
|
|
optIfODUkTtpCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUk configuration objects
|
|
applicable to all interfaces that support
|
|
ODUk trail termination sink functions."
|
|
::= { optIfGroups 36 }
|
|
|
|
optIfODUkNimGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkNimDAPIExpected,
|
|
optIfODUkNimSAPIExpected,
|
|
optIfODUkNimTraceIdentifierAccepted,
|
|
optIfODUkNimTIMDetMode,
|
|
optIfODUkNimTIMActEnabled,
|
|
optIfODUkNimDEGThr,
|
|
optIfODUkNimDEGM,
|
|
optIfODUkNimCurrentStatus,
|
|
optIfODUkNimRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUk Nim configuration objects."
|
|
::= { optIfGroups 37 }
|
|
|
|
optIfGCC12Group OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfGCC12GCCPassThrough,
|
|
optIfGCC12Application,
|
|
optIfGCC12RowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of GCC12 configuration objects."
|
|
::= { optIfGroups 38 }
|
|
|
|
optIfODUkTCommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances."
|
|
::= { optIfGroups 39 }
|
|
|
|
optIfODUkTSourceGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTTraceIdentifierTransmitted,
|
|
optIfODUkTSourceLockSignalAdminState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances
|
|
that provide source functions."
|
|
::= { optIfGroups 40 }
|
|
|
|
optIfODUkTSinkGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTDAPIExpected,
|
|
optIfODUkTSAPIExpected,
|
|
optIfODUkTTraceIdentifierAccepted,
|
|
optIfODUkTTIMDetMode,
|
|
optIfODUkTTIMActEnabled,
|
|
optIfODUkTDEGThr,
|
|
optIfODUkTDEGM,
|
|
optIfODUkTCurrentStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to all ODUkT instances
|
|
that provide sink functions."
|
|
::= { optIfGroups 41 }
|
|
|
|
optIfODUkTSinkGroupCtp OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTSinkMode,
|
|
optIfODUkTSinkLockSignalAdminState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of configuration objects
|
|
applicable to ODUkT instances not
|
|
colocated with an ODUk TTP that
|
|
provide sink functions."
|
|
::= { optIfGroups 42 }
|
|
|
|
optIfODUkTNimGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
optIfODUkTNimDAPIExpected,
|
|
optIfODUkTNimSAPIExpected,
|
|
optIfODUkTNimTraceIdentifierAccepted,
|
|
optIfODUkTNimTIMDetMode,
|
|
optIfODUkTNimTIMActEnabled,
|
|
optIfODUkTNimDEGThr,
|
|
optIfODUkTNimDEGM,
|
|
optIfODUkTNimCurrentStatus,
|
|
optIfODUkTNimRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of ODUkT Nim configuration objects."
|
|
::= { optIfGroups 43 }
|
|
|
|
|
|
END
|
|
|