- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1631 lines
No EOL
44 KiB
Text
Executable file
1631 lines
No EOL
44 KiB
Text
Executable file
-- INOVONICS MODEL 650 SMIV2 SPECIFICATION MIB
|
|
|
|
INOVONICS-MODEL650-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,enterprises,
|
|
Integer32,IpAddress FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,DisplayString FROM SNMPv2-TC;
|
|
|
|
model650 MODULE-IDENTITY
|
|
LAST-UPDATED "201602020000Z"
|
|
ORGANIZATION "Inovonics, Inc."
|
|
CONTACT-INFO
|
|
"www.inovonicsbroadcast.com"
|
|
DESCRIPTION
|
|
"The MIB for the Model 650 AARON FM Rebroadcast Receiver."
|
|
|
|
REVISION "201602020000Z"
|
|
DESCRIPTION
|
|
"Second MIB version. Entire MIB overhauled to add OID for every parameter."
|
|
::= { inovonicsBroadcast 650 }
|
|
|
|
inovonicsBroadcast OBJECT IDENTIFIER ::= { enterprises 42111 }
|
|
|
|
traps OBJECT IDENTIFIER ::= { model650 1 }
|
|
notifications OBJECT IDENTIFIER ::= { traps 0 }
|
|
product OBJECT IDENTIFIER ::= { model650 2 }
|
|
nowPlaying OBJECT IDENTIFIER ::= { model650 3 }
|
|
receptionTools OBJECT IDENTIFIER ::= { model650 4 }
|
|
bandwidthIF OBJECT IDENTIFIER ::= { receptionTools 1 }
|
|
stereoBlend OBJECT IDENTIFIER ::= { receptionTools 2 }
|
|
highBlend OBJECT IDENTIFIER ::= { receptionTools 3 }
|
|
bandBlend OBJECT IDENTIFIER ::= { receptionTools 4 }
|
|
highcut OBJECT IDENTIFIER ::= { receptionTools 5 }
|
|
rds OBJECT IDENTIFIER ::= { model650 5 }
|
|
alarms OBJECT IDENTIFIER ::= { model650 6 }
|
|
alarmStatus OBJECT IDENTIFIER ::= { alarms 1 }
|
|
audioLoss OBJECT IDENTIFIER ::= { alarms 2 }
|
|
lowSignal OBJECT IDENTIFIER ::= { alarms 3 }
|
|
rdsLoss OBJECT IDENTIFIER ::= { alarms 4 }
|
|
pilotLoss OBJECT IDENTIFIER ::= { alarms 5 }
|
|
audioFailover OBJECT IDENTIFIER ::= { alarms 6 }
|
|
stereoRegen OBJECT IDENTIFIER ::= { model650 7 }
|
|
regenPilot OBJECT IDENTIFIER ::= { stereoRegen 2 }
|
|
regenRDS OBJECT IDENTIFIER ::= { stereoRegen 3 }
|
|
setup OBJECT IDENTIFIER ::= { model650 8 }
|
|
outputs OBJECT IDENTIFIER ::= { setup 1 }
|
|
network OBJECT IDENTIFIER ::= { setup 2 }
|
|
dynDNS OBJECT IDENTIFIER ::= { setup 3 }
|
|
time OBJECT IDENTIFIER ::= { setup 4 }
|
|
snmp OBJECT IDENTIFIER ::= { setup 5 }
|
|
email OBJECT IDENTIFIER ::= { setup 6 }
|
|
alarmLog OBJECT IDENTIFIER ::= { setup 7 }
|
|
alarmPolarity OBJECT IDENTIFIER ::= { setup 8 }
|
|
region OBJECT IDENTIFIER ::= { setup 9 }
|
|
testOscillator OBJECT IDENTIFIER ::= { setup 10 }
|
|
passwords OBJECT IDENTIFIER ::= { model650 9 }
|
|
|
|
-- Custom defined textual-conventions
|
|
|
|
OnOff ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents a boolean value."
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
|
|
----------------------------------
|
|
-- Traps
|
|
----------------------------------
|
|
|
|
audioLossTrap NOTIFICATION-TYPE
|
|
OBJECTS { audioLossAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap occurs when the Audio Loss alarm is triggered on OR off.
|
|
The status of the alarm is included as a variable binding in the form
|
|
of the audioLossAlarm object."
|
|
::= {notifications 1}
|
|
|
|
lowSignalTrap NOTIFICATION-TYPE
|
|
OBJECTS { lowSignalAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap occurs when the Low Signal alarm is triggered on OR off.
|
|
The status of the alarm is included as a variable binding in the form
|
|
of the lowSignalAlarm object."
|
|
::= {notifications 2}
|
|
|
|
rdsErrorTrap NOTIFICATION-TYPE
|
|
OBJECTS { rdsErrorAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap occurs when the RDS Error/Mismatch alarm is triggered on OR off.
|
|
The status of the alarm is included as a variable binding in the form
|
|
of the rdsErrorAlarm object."
|
|
::= {notifications 3}
|
|
|
|
pilotLossTrap NOTIFICATION-TYPE
|
|
OBJECTS { pilotLossAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap occurs when the Pilot Loss alarm is triggered on OR off.
|
|
The status of the alarm is included as a variable binding in the form
|
|
of the pilotLossAlarm object."
|
|
::= {notifications 4}
|
|
|
|
----------------------------------
|
|
-- Product Info
|
|
----------------------------------
|
|
|
|
serial OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number."
|
|
::= { product 1 }
|
|
|
|
version OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firmware version."
|
|
::= { product 2 }
|
|
|
|
date OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date of firmware version."
|
|
::= { product 3 }
|
|
|
|
----------------------------------
|
|
-- Now Playing
|
|
----------------------------------
|
|
|
|
frequency OBJECT-TYPE
|
|
SYNTAX Integer32 (6500..10800)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Currently tuned frequency, in 10kHz steps. Can be set
|
|
between 6500 and 10800."
|
|
::= { nowPlaying 1 }
|
|
|
|
currentPreset OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Currently selected preset. The preset can
|
|
also be set to 1-10. A value of 0 means a
|
|
preset is not selected."
|
|
::= { nowPlaying 2 }
|
|
|
|
antenna OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Currently selected antenna. Can be
|
|
set to antenna 1 or 2."
|
|
::= { nowPlaying 3 }
|
|
|
|
rssi OBJECT-TYPE
|
|
SYNTAX Integer32 (0..120)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Relative Signal Strength Indicator
|
|
(RF strength). The range is 0-120dBuV."
|
|
::= { nowPlaying 4 }
|
|
|
|
bandwidth OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IF Bandwidth (units: kHz)."
|
|
::= { nowPlaying 5 }
|
|
|
|
multipath OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of Multipath. The Range is 0-100%."
|
|
::= { nowPlaying 6 }
|
|
|
|
noise OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of Ultrasonic Noise. The Range is 0-100%."
|
|
::= { nowPlaying 7 }
|
|
|
|
leftLeveldB OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..6)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Left channel level (units: dB)."
|
|
::= { nowPlaying 8 }
|
|
|
|
rightLeveldB OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..6)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Right channel level (units: dB)."
|
|
::= { nowPlaying 9 }
|
|
|
|
leftPlusRightLeveldB OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..6)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Left+Right level (units: dB)."
|
|
::= { nowPlaying 10 }
|
|
|
|
leftMinusRightLeveldB OBJECT-TYPE
|
|
SYNTAX Integer32 (-128..6)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Left-Right level (units: dB)."
|
|
::= { nowPlaying 11 }
|
|
|
|
status OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This describes the current status, such as if everything is
|
|
normal or if a backup source is in use."
|
|
::= { nowPlaying 12 }
|
|
|
|
----------------------------------
|
|
-- RECEPTION TOOLS
|
|
----------------------------------
|
|
|
|
bandwidthMode OBJECT-TYPE
|
|
SYNTAX INTEGER { fixed(0), auto(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IF Bandwidth Mode - set to automatically adjust IF bandwidth, or
|
|
used a fixed bandwidth set by the fixedBandwidth OID."
|
|
::= { bandwidthIF 1 }
|
|
|
|
fixedBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER { bw56kHz(0), bw64kHz(1), bw72kHz(2), bw84kHz(3), bw97kHz(4), bw114kHz(5), bw133kHz(6), bw151kHz(7), bw168kHz(8), bw184kHz(9),
|
|
bw200kHz(10), bw217kHz(11), bw236kHz(12), bw254kHz(13), bw287kHz(14), bw311kHz(15) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IF Bandwidth used when the mode is set to fixed."
|
|
::= { bandwidthIF 2 }
|
|
|
|
----------------------------------
|
|
-- Reception Tools - Stereo Blend
|
|
----------------------------------
|
|
|
|
stereoBlendAmount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of stereo blend processing applied (Units: %)."
|
|
::= { stereoBlend 1 }
|
|
|
|
stereoBlendAuto OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to auto, the blend processing is handled automatically.
|
|
the other stereo blend settings are not used."
|
|
::= { stereoBlend 2 }
|
|
|
|
stereoBlendUseRSSI OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use RSSI as a metric for blend processing."
|
|
::= { stereoBlend 3 }
|
|
|
|
stereoBlendThresholdRSSI OBJECT-TYPE
|
|
SYNTAX Integer32 (30..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the RSSI drops below this set value, more blending will occur (Units: dBuV)."
|
|
::= { stereoBlend 4 }
|
|
|
|
stereoBlendUseUSN OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use USN as a metric for blend processing."
|
|
::= { stereoBlend 5 }
|
|
|
|
stereoBlendThresholdUSN OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the USN goes above this set value, more blending will occur (Units: %)."
|
|
::= { stereoBlend 6 }
|
|
|
|
stereoBlendUseMultipath OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use multipath as a metric for blend processing."
|
|
::= { stereoBlend 7 }
|
|
|
|
stereoBlendThresholdMultipath OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the multipath goes above this set value, more blending will occur (Units: %)."
|
|
::= { stereoBlend 8 }
|
|
|
|
----------------------------------
|
|
-- Reception Tools - High Blend
|
|
----------------------------------
|
|
|
|
highBlendAmount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of stereo blend processing applied (Units: %)."
|
|
::= { highBlend 1 }
|
|
|
|
highBlendAuto OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to auto, the high blend processing is handled automatically.
|
|
the other high blend settings are not used."
|
|
::= { highBlend 2 }
|
|
|
|
highBlendUseRSSI OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use RSSI as a metric for high blend processing."
|
|
::= { highBlend 3 }
|
|
|
|
highBlendThresholdRSSI OBJECT-TYPE
|
|
SYNTAX Integer32 (30..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the RSSI drops below this set value, more high blending will occur (Units: dBuV)."
|
|
::= { highBlend 4 }
|
|
|
|
highBlendUseUSN OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use USN as a metric for high blend processing."
|
|
::= { highBlend 5 }
|
|
|
|
highBlendThresholdUSN OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the USN goes above this set value, more high blending will occur (Units: %)."
|
|
::= { highBlend 6 }
|
|
|
|
highBlendUseMultipath OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use multipath as a metric for high blend processing."
|
|
::= { highBlend 7 }
|
|
|
|
highBlendThresholdMultipath OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the multipath goes above this set value, more high blending will occur (Units: %)."
|
|
::= { highBlend 8 }
|
|
|
|
----------------------------------
|
|
-- Reception Tools - Band Blend
|
|
----------------------------------
|
|
|
|
bandBlendEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable 4 band blend processing."
|
|
::= { bandBlend 1 }
|
|
|
|
bandBlendControl OBJECT-TYPE
|
|
SYNTAX Integer32 (50..150)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the agressiveness of the 4 band blend."
|
|
::= { bandBlend 2 }
|
|
|
|
bandBlendLF OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of blending in the Low Frequency band (Units: %)."
|
|
::= { bandBlend 3 }
|
|
|
|
bandBlend2k OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of blending in the 2kHz band (Units: %)."
|
|
::= { bandBlend 4 }
|
|
|
|
bandBlend5k OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of blending in the 5kHz band (Units: %)."
|
|
::= { bandBlend 5 }
|
|
|
|
bandBlendHF OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The amount of blending in the High Frequency band (Units: %)."
|
|
::= { bandBlend 6 }
|
|
|
|
----------------------------------
|
|
-- Reception Tools - Highcut
|
|
----------------------------------
|
|
|
|
highcutAmount OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of highcut processing applied (Units: %)."
|
|
::= { highcut 1 }
|
|
|
|
highcutAuto OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If set to auto, the highcut processing is handled automatically.
|
|
the other high blend settings are not used."
|
|
::= { highcut 2 }
|
|
|
|
highcutUseRSSI OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use RSSI as a metric for highcut processing."
|
|
::= { highcut 3 }
|
|
|
|
highcutThresholdRSSI OBJECT-TYPE
|
|
SYNTAX Integer32 (30..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the RSSI drops below this set value, more highcut will occur (Units: dBuV)."
|
|
::= { highcut 4 }
|
|
|
|
highcutUseUSN OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use USN as a metric for highcut processing."
|
|
::= { highcut 5 }
|
|
|
|
highcutThresholdUSN OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the USN goes above this set value, more highcut will occur (Units: %)."
|
|
::= { highcut 6 }
|
|
|
|
highcutUseMultipath OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set ON to use multipath as a metric for highcut processing."
|
|
::= { highcut 7 }
|
|
|
|
highcutThresholdMultipath OBJECT-TYPE
|
|
SYNTAX Integer32 (0..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"As the multipath goes above this set value, more highcut will occur (Units: %)."
|
|
::= { highcut 8 }
|
|
|
|
----------------------------------
|
|
-- Reception Tools - Misc
|
|
----------------------------------
|
|
|
|
monoStereo OBJECT-TYPE
|
|
SYNTAX INTEGER { forcedMono(0), stereo(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to forced mono or stereo (auto)."
|
|
::= { receptionTools 6 }
|
|
|
|
multipathSuppression OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the use of Multipath Suppression processing."
|
|
::= { receptionTools 7 }
|
|
|
|
channelEqualizer OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls the use of the Channel Equalizer."
|
|
::= { receptionTools 8 }
|
|
|
|
----------------------------------
|
|
-- RDS
|
|
----------------------------------
|
|
|
|
pi OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PI (Program Identification) Code."
|
|
::= { rds 1 }
|
|
|
|
call OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Callsign/Call Letters for the received PI Code."
|
|
::= { rds 2 }
|
|
|
|
ps OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PS (Program Service)."
|
|
::= { rds 3 }
|
|
|
|
rt OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RT (Radio Text)."
|
|
::= { rds 4 }
|
|
|
|
pty OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PTY (Program Type)."
|
|
::= { rds 5 }
|
|
|
|
ptyn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PTYN (Program Type Name)."
|
|
::= { rds 6 }
|
|
|
|
rdsTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RDS time received."
|
|
::= { rds 7 }
|
|
|
|
ms OBJECT-TYPE
|
|
SYNTAX INTEGER { speech(0), music(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Music/Speech flag."
|
|
::= { rds 8 }
|
|
|
|
di OBJECT-TYPE
|
|
SYNTAX INTEGER { mono(0), stereo(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mono/Stereo flag."
|
|
::= { rds 9 }
|
|
|
|
tp OBJECT-TYPE
|
|
SYNTAX INTEGER { off(0), on(1) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic Programming flag."
|
|
::= { rds 10 }
|
|
|
|
ta OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic Alert flag."
|
|
::= { rds 11 }
|
|
|
|
----------------------------------
|
|
-- ALARMS
|
|
----------------------------------
|
|
----------------------------------
|
|
-- Alarms - Status
|
|
----------------------------------
|
|
|
|
audioLossAlarm OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the Audio Loss alarm."
|
|
::= { alarmStatus 1 }
|
|
|
|
lowSignalAlarm OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the Low Signal alarm."
|
|
::= { alarmStatus 2 }
|
|
|
|
rdsErrorAlarm OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the RDS Error/Mismatch alarm."
|
|
::= { alarmStatus 3 }
|
|
|
|
pilotLossAlarm OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the Pilot Loss alarm."
|
|
::= { alarmStatus 4 }
|
|
|
|
----------------------------------
|
|
-- Alarms - Audio Loss
|
|
----------------------------------
|
|
|
|
audioLossEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable the Audio Loss alarm."
|
|
::= { audioLoss 1 }
|
|
|
|
audioLossThreshOn OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..0)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for alarm turning on (units: dB)."
|
|
::= { audioLoss 2 }
|
|
|
|
audioLossThreshOff OBJECT-TYPE
|
|
SYNTAX Integer32 (-40..0)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for alarm turning off (units: dB)."
|
|
::= { audioLoss 3 }
|
|
|
|
audioLossTimeOn OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the audio level must be below the Threshold On
|
|
value before the alarm turns on (units: seconds)."
|
|
::= { audioLoss 4 }
|
|
|
|
audioLossTimeOff OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the audio level must be above the Threshold On
|
|
value before the alarm turns off (units: seconds)."
|
|
::= { audioLoss 5 }
|
|
|
|
----------------------------------
|
|
-- Alarms - Low Signal
|
|
----------------------------------
|
|
|
|
lowSignalEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable the Low Signal alarm."
|
|
::= { lowSignal 1 }
|
|
|
|
lowSignalMute OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled, radio will mute when Low Signal alarm is on."
|
|
::= { lowSignal 2 }
|
|
|
|
lowSignalThreshOn OBJECT-TYPE
|
|
SYNTAX Integer32 (0..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for alarm turning on (units: dBuV)."
|
|
::= { lowSignal 3 }
|
|
|
|
lowSignalThreshOff OBJECT-TYPE
|
|
SYNTAX Integer32 (0..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold for alarm turning off (units: dBuV)."
|
|
::= { lowSignal 4 }
|
|
|
|
lowSignalTimeOn OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the RSSI level must be below the Threshold On
|
|
value before the alarm turns on (units: seconds)."
|
|
::= { lowSignal 5 }
|
|
|
|
lowSignalTimeOff OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the RSSI level must be above the Threshold Off
|
|
value before the alarm turns off (units: seconds)."
|
|
::= { lowSignal 6 }
|
|
|
|
----------------------------------
|
|
-- Alarms - RDS Loss
|
|
----------------------------------
|
|
|
|
rdsLossEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable the RDS Error alarm."
|
|
::= { rdsLoss 1 }
|
|
|
|
rdsPIErrorEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled, the alarm will occur if RDS is present but the received PI does
|
|
not match that set in rdsPICode."
|
|
::= { rdsLoss 2 }
|
|
|
|
rdsPICode OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set PI Code to compare with received PI."
|
|
::= { rdsLoss 3 }
|
|
|
|
rdsLossTimeOn OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the RDS must be gone/PI Code incorrect
|
|
before the alarm turns on (units: seconds)."
|
|
::= { rdsLoss 4 }
|
|
|
|
rdsLossTimeOff OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the RDS must be present/PI Code correct
|
|
before the alarm turns off (units: seconds)."
|
|
::= { rdsLoss 5 }
|
|
|
|
----------------------------------
|
|
-- Alarms - Pilot Loss
|
|
----------------------------------
|
|
|
|
pilotLossEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable the Pilot Loss alarm."
|
|
::= { pilotLoss 1 }
|
|
|
|
pilotLossTimeOn OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the pilot must be gone
|
|
before the alarm turns on (units: seconds)."
|
|
::= { pilotLoss 2 }
|
|
|
|
pilotLossTimeOff OBJECT-TYPE
|
|
SYNTAX Integer32 (1..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amount of time the pilot must be present
|
|
before the alarm turns off (units: seconds)."
|
|
::= { pilotLoss 3 }
|
|
|
|
----------------------------------
|
|
-- Alarms - Audio Failover
|
|
----------------------------------
|
|
|
|
failoverAudio OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Audio Failover to backup source will occur when there is an
|
|
Audio Loss alarm."
|
|
::= { audioFailover 1 }
|
|
|
|
failoverRSSI OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Audio Failover to backup source will occur when there is a
|
|
Low Signal alarm."
|
|
::= { audioFailover 2 }
|
|
|
|
failoverRDS OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Audio Failover to backup source will occur when there is a
|
|
RDS alarm."
|
|
::= { audioFailover 3 }
|
|
|
|
failoverSource OBJECT-TYPE
|
|
SYNTAX INTEGER { stream(0), sdCard(1), streamToSD(2), nextPreset(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The backup audio source to use when the failover is triggered."
|
|
::= { audioFailover 4 }
|
|
|
|
failoverStreamURL OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The URL for the backup stream."
|
|
::= { audioFailover 5 }
|
|
|
|
----------------------------------
|
|
-- STEREO REGEN
|
|
----------------------------------
|
|
|
|
regenMode OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to off (Composite Pass-Through) or on (Composite Regen)."
|
|
::= { stereoRegen 1 }
|
|
|
|
----------------------------------
|
|
-- Stereo Regen - Pilot
|
|
----------------------------------
|
|
|
|
regenPilotEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Turn the pilot on/off when in regen mode."
|
|
::= { regenPilot 1 }
|
|
|
|
regenPilotInjection OBJECT-TYPE
|
|
SYNTAX Integer32 (60..120)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The pilot injection level when in regen mode
|
|
(Units: 0.1%, Ex: 90 = 9.0%)."
|
|
::= { regenPilot 2 }
|
|
|
|
----------------------------------
|
|
-- Stereo Regen - RDS
|
|
----------------------------------
|
|
|
|
regenRDSEnable OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Turn RDS on/off when in regen mode."
|
|
::= { regenRDS 1 }
|
|
|
|
regenRDSInjection OBJECT-TYPE
|
|
SYNTAX Integer32 (30..80)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RDS injection level when in regen mode
|
|
(Units: 0.1%, Ex: 50 = 5.0%)."
|
|
::= { regenRDS 2 }
|
|
|
|
regenRDSMode OBJECT-TYPE
|
|
SYNTAX INTEGER { reencode(0), reencodeWithNewPI(1), builtIn(2), builtInWithTime(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets how the RDS should be regenerated."
|
|
::= { regenRDS 3 }
|
|
|
|
builtInScrollSpeed OBJECT-TYPE
|
|
SYNTAX Integer32 (1..9)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets how quickly the PS field will scroll with the built-in RDS.
|
|
Higher values can cause jumbled characters on some radios."
|
|
::= { regenRDS 4 }
|
|
|
|
builtInPI OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS PI Code (also used for re-encode with new PI mode)."
|
|
::= { regenRDS 5 }
|
|
|
|
builtInPS OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..128))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS PS text. The RDS encoder will automatically parse
|
|
longer messages."
|
|
::= { regenRDS 6 }
|
|
|
|
builtInRT OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..64))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS Radio Text."
|
|
::= { regenRDS 7 }
|
|
|
|
builtInPTY OBJECT-TYPE
|
|
SYNTAX Integer32 (0..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS Program Type."
|
|
::= { regenRDS 8 }
|
|
|
|
builtInMS OBJECT-TYPE
|
|
SYNTAX INTEGER { speech(0), music(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS Music/Speed flag."
|
|
::= { regenRDS 9 }
|
|
|
|
builtInDI OBJECT-TYPE
|
|
SYNTAX INTEGER { mono(0), stereo(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS stereo/mono flag."
|
|
::= { regenRDS 10 }
|
|
|
|
builtInTP OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Built-in RDS Traffic Programming flag."
|
|
::= { regenRDS 11 }
|
|
|
|
----------------------------------
|
|
-- SETUP
|
|
----------------------------------
|
|
----------------------------------
|
|
-- Setup - Outputs
|
|
----------------------------------
|
|
|
|
analogLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-200..180)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Analog Output level
|
|
(Units: 0.1dB, Ex. -100 = -10.0dB)."
|
|
::= { outputs 1 }
|
|
|
|
analogDeemphasis OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"De-emphasis applied to analog outputs."
|
|
::= { outputs 2 }
|
|
|
|
digitalLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-300..0)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Digital Output level
|
|
(Units: 0.1dB, Ex. -200 = -20.0dB)."
|
|
::= { outputs 3 }
|
|
|
|
digitalDeemphasis OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"De-emphasis applied to AES output."
|
|
::= { outputs 4 }
|
|
|
|
digitalSamplerate OBJECT-TYPE
|
|
SYNTAX INTEGER { sr32kHz(0), sr44kHz(1), sr48kHz(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sample Rate of the AES output."
|
|
::= { outputs 5 }
|
|
|
|
mpx1Level OBJECT-TYPE
|
|
SYNTAX Integer32 (1000..6000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MPX1 Output level (Units: mVpp, Ex. 3100 = 3.10Vpp).
|
|
Though the units are mVpp, the resolution is less than 1mVpp.
|
|
When this value is set, it will round to the closest possible value."
|
|
::= { outputs 6 }
|
|
|
|
mpx2Level OBJECT-TYPE
|
|
SYNTAX Integer32 (1000..6000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MPX2 Output level (Units: mVpp, Ex. 3100 = 3.10Vpp).
|
|
Though the units are mVpp, the resolution is less than 1mVpp.
|
|
When this value is set, it will round to the closest possible value."
|
|
::= { outputs 7 }
|
|
|
|
mpxClipping OBJECT-TYPE
|
|
SYNTAX Integer32 (-20..30)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MPX Clipping amount (Units: 0.1dB, Ex. 16 = 1.6dB.
|
|
This can be set in 0.2dB steps."
|
|
::= { outputs 8 }
|
|
|
|
----------------------------------
|
|
-- Setup - Network
|
|
----------------------------------
|
|
|
|
dhcp OBJECT-TYPE
|
|
SYNTAX INTEGER { staticIP(0), dhcpEnabled(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DHCP enabled, or disabled (static IP)."
|
|
::= { network 1 }
|
|
|
|
ip OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device IP Address."
|
|
::= { network 2 }
|
|
|
|
gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway IP Address."
|
|
::= { network 3 }
|
|
|
|
subnet OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device subnet mask."
|
|
::= { network 4 }
|
|
|
|
dns OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device DNS address."
|
|
::= { network 5 }
|
|
|
|
httpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HTTP port for webserver."
|
|
::= { network 6 }
|
|
|
|
hostname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..16))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NBNS hostname."
|
|
::= { network 7 }
|
|
|
|
mac OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of this device."
|
|
::= { network 8 }
|
|
|
|
----------------------------------
|
|
-- Setup - Dynamic DNS
|
|
----------------------------------
|
|
|
|
ddnsMode OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), dyn(1), noip(2), dnsomatic(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dynamic DNS provider/mode."
|
|
::= { dynDNS 1 }
|
|
|
|
ddnsHostname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Your DDNS hostname (proper web addess)."
|
|
::= { dynDNS 2 }
|
|
|
|
ddnsUsername OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The username for your DDNS account."
|
|
::= { dynDNS 3 }
|
|
|
|
ddnsPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (1..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for your DDNS account."
|
|
::= { dynDNS 4 }
|
|
|
|
ddnsStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of the DDNS service."
|
|
::= { dynDNS 5 }
|
|
|
|
----------------------------------
|
|
-- Setup - Time
|
|
----------------------------------
|
|
|
|
timezone OBJECT-TYPE
|
|
SYNTAX Integer32 (-120..140)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UTC offset (Units: 0.1hours). EX: -80 = UTC-8.0.
|
|
Can be set in 0.5 hour increments."
|
|
::= { time 1 }
|
|
|
|
dst OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Whether Daylight Saving Time is currently in effect."
|
|
::= { time 2 }
|
|
|
|
autodst OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable to automatically follow US Daylight Saving Time."
|
|
::= { time 3 }
|
|
|
|
timeServer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"URL for a custom NTP time server."
|
|
::= { time 4 }
|
|
|
|
----------------------------------
|
|
-- Setup - SNMP
|
|
----------------------------------
|
|
|
|
snmpMode OBJECT-TYPE
|
|
SYNTAX INTEGER { disabled(0), readOnly(1), readWrite(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP mode. Restrict SNMP read or write."
|
|
::= { snmp 1 }
|
|
|
|
snmpReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP read community string for read access."
|
|
::= { snmp 2 }
|
|
|
|
snmpWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP write community string for write access."
|
|
::= { snmp 3 }
|
|
|
|
snmpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UDP port for SNMP communication.
|
|
SNMP standard is UDP port 161."
|
|
::= { snmp 4 }
|
|
|
|
snmpTrapsPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"UDP port for SNMP traps.
|
|
SNMP standard is UDP port 162."
|
|
::= { snmp 5 }
|
|
|
|
snmpTrapDestination1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address 1 to send traps to."
|
|
::= { snmp 6 }
|
|
|
|
snmpTrapDestination2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address 2 to send traps to."
|
|
::= { snmp 7 }
|
|
|
|
snmpTrapDestination3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address 3 to send traps to."
|
|
::= { snmp 8 }
|
|
|
|
----------------------------------
|
|
-- Setup - Email
|
|
----------------------------------
|
|
|
|
smtpServer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"URL or IP of SMTP server."
|
|
::= { email 1 }
|
|
|
|
smtpPort OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCP port for SMTP (depends on server)."
|
|
::= { email 2 }
|
|
|
|
ssl OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable SSL security for connection
|
|
to SMTP server."
|
|
::= { email 3 }
|
|
|
|
emailFrom OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will show as the 'From' when you receive
|
|
emails from this unit."
|
|
::= { email 4 }
|
|
|
|
emailUsername OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The email address to send from."
|
|
::= { email 5 }
|
|
|
|
emailPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password to the email address to send from."
|
|
::= { email 6 }
|
|
|
|
recipientTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RecipientEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table of 10 email recipients."
|
|
::= { email 7 }
|
|
|
|
recipientEntry OBJECT-TYPE
|
|
SYNTAX RecipientEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Single recipient entry."
|
|
INDEX { recipientIndex }
|
|
::= { recipientTable 1 }
|
|
|
|
RecipientEntry ::= SEQUENCE {
|
|
recipientIndex Integer32,
|
|
emailAddress DisplayString,
|
|
audioLossEmail OnOff,
|
|
lowSignalEmail OnOff,
|
|
rdsLossEmail OnOff,
|
|
pilotLossEmail OnOff,
|
|
dailyLogEmail OnOff,
|
|
weeklyLogEmail OnOff,
|
|
monthlyLogEmail OnOff
|
|
}
|
|
|
|
recipientIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..10)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of recipient (recipients 1 through 10)."
|
|
::= { recipientEntry 1 }
|
|
|
|
emailAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Email address for the recipient of email notifications."
|
|
::= { recipientEntry 2 }
|
|
|
|
audioLossEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive Audio Loss emails."
|
|
::= { recipientEntry 3 }
|
|
|
|
lowSignalEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive Low Signal emails."
|
|
::= { recipientEntry 4 }
|
|
|
|
rdsLossEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive RDS Loss emails."
|
|
::= { recipientEntry 5 }
|
|
|
|
pilotLossEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive Pilot Loss emails."
|
|
::= { recipientEntry 6 }
|
|
|
|
dailyLogEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive daily log emails."
|
|
::= { recipientEntry 7 }
|
|
|
|
weeklyLogEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive weekly log emails."
|
|
::= { recipientEntry 8 }
|
|
|
|
monthlyLogEmail OBJECT-TYPE
|
|
SYNTAX OnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This recipient will receive monthly log emails."
|
|
::= { recipientEntry 9 }
|
|
|
|
----------------------------------
|
|
-- Setup - Alarm Log Settings
|
|
----------------------------------
|
|
|
|
alarmLogStatus OBJECT-TYPE
|
|
SYNTAX Integer32 (0..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fullness of alarm log (units: %). Set to 0 to clear the alarm log."
|
|
::= { alarmLog 1 }
|
|
|
|
alarmLogFullEmail OBJECT-TYPE
|
|
SYNTAX Integer32 (1..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Send an email reminder when the log is (%) full."
|
|
::= { alarmLog 2 }
|
|
|
|
----------------------------------
|
|
-- Setup - Alarm Polarity
|
|
----------------------------------
|
|
|
|
audioLossPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER { activeGround(0), activeOpen(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity of the Audio Loss alarm output."
|
|
::= { alarmPolarity 1 }
|
|
|
|
lowSignalPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER { activeGround(0), activeOpen(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity of the Low Signal alarm output."
|
|
::= { alarmPolarity 2 }
|
|
|
|
rdsLossPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER { activeGround(0), activeOpen(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity of the RDS Loss alarm output."
|
|
::= { alarmPolarity 3 }
|
|
|
|
pilotLossPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER { activeGround(0), activeOpen(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity of the Pilot Loss alarm output."
|
|
::= { alarmPolarity 4 }
|
|
|
|
----------------------------------
|
|
-- Setup - Region
|
|
----------------------------------
|
|
|
|
tuningSteps OBJECT-TYPE
|
|
SYNTAX INTEGER { tune10kHz(0), tune100kHz(1), tune200kHz(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The step size used when tuning from the front panel and web."
|
|
::= { region 1 }
|
|
|
|
deemphasis OBJECT-TYPE
|
|
SYNTAX INTEGER { deemph50us(0), deemph75us(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set deemphasis to 50us or 75us."
|
|
::= { region 2 }
|
|
|
|
rdsDecodeMode OBJECT-TYPE
|
|
SYNTAX INTEGER { rds(0), rbds(1) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set RDS decoding mode to RDS (Europe) or RBDS (North America)."
|
|
::= { region 3 }
|
|
|
|
----------------------------------
|
|
-- Setup - Test Oscillator
|
|
----------------------------------
|
|
|
|
oscMode OBJECT-TYPE
|
|
SYNTAX INTEGER { oscOff(0), oscLeft(1), oscRight(2), oscLeftRight(3) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable the internal tone generator for testing purposes."
|
|
::= { testOscillator 1 }
|
|
|
|
oscFrequency OBJECT-TYPE
|
|
SYNTAX Integer32 (10..20000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Frequency of the test oscillator (Units: Hz).
|
|
Can be set in multiples of 10Hz."
|
|
::= { testOscillator 2 }
|
|
|
|
oscLevel OBJECT-TYPE
|
|
SYNTAX Integer32 (-30..0)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Level of the test oscillator (Units: dB)."
|
|
::= { testOscillator 3 }
|
|
|
|
----------------------------------
|
|
-- Setup - Misc
|
|
----------------------------------
|
|
|
|
serialPortBaudRate OBJECT-TYPE
|
|
SYNTAX INTEGER { baud9600(0), baud19200(1), baud38400(2), baud57600(3), baud115200(4) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/disable the internal tone generator for testing purposes."
|
|
::= { setup 11 }
|
|
|
|
----------------------------------
|
|
-- Passwords
|
|
----------------------------------
|
|
|
|
frontPanelPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for restricting front panel access."
|
|
::= { passwords 1 }
|
|
|
|
webpagesPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..31))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for restricting webpage access."
|
|
::= { passwords 2 }
|
|
|
|
END |