- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
399 lines
16 KiB
Text
399 lines
16 KiB
Text
HP-ICF-LINKTEST DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Integer32, OBJECT-TYPE, MODULE-IDENTITY
|
|
FROM SNMPv2-SMI
|
|
RowStatus, TimeInterval
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
OwnerString
|
|
FROM RMON-MIB
|
|
hpicfObjectModules, hpicfCommon
|
|
FROM HP-ICF-OID;
|
|
|
|
hpicfLinkTestMib MODULE-IDENTITY
|
|
LAST-UPDATED "200011032225Z" -- November 3, 2000
|
|
ORGANIZATION "Hewlett Packard Company,
|
|
Network Infrastructure Solutions"
|
|
CONTACT-INFO
|
|
"Hewlett Packard Company
|
|
8000 Foothills Blvd.
|
|
Roseville, CA 95747"
|
|
DESCRIPTION
|
|
"This MIB module describes objects for managing
|
|
the link test features of devices in the HP
|
|
Integrated Communication Facility product line."
|
|
|
|
REVISION "200011032225Z" -- November 3, 2000
|
|
DESCRIPTION "Updated division name."
|
|
|
|
REVISION "9703060338Z" -- March 6, 1997
|
|
DESCRIPTION
|
|
"Added 'destroyWhenDone' capability."
|
|
REVISION "9609062218Z" -- September 6, 1996
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
::= { hpicfObjectModules 7 }
|
|
|
|
|
|
|
|
-- The HP ICF Linktest Group
|
|
|
|
hpicfLinktest OBJECT IDENTIFIER ::= { hpicfCommon 6 }
|
|
|
|
hpicfLinkTestNextIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A currently unassigned value of hpicfLinkTestIndex.
|
|
The value 0 indicates that no unassigned values are
|
|
available.
|
|
|
|
In order to cause a non-zero value of this object to
|
|
be assigned for use as the hpicfLinkTestIndex of a
|
|
future link test, it must be successfully modified by
|
|
a set operation. When modified by a set operation,
|
|
the new value must precisely match the value
|
|
presently held by the object. If not, the management
|
|
protocol set operation will fail.
|
|
|
|
Immediately after the completion of a successful set
|
|
operation, the agent must modify the value of this
|
|
object. The algorithm for modifying the value is
|
|
implementation-dependent, and may use a subset of
|
|
values within the legal range. However, the agent
|
|
must guarantee that the new value is not assigned to
|
|
any in-use value of hpicfLinkTestIndex.
|
|
|
|
A management station creates a new link test using
|
|
this algorithm:
|
|
|
|
- issue a management protocol retrieval operation
|
|
to obtain the value of hpicfLinkTestNextIndex;
|
|
if the retrieved value is zero, a new link test
|
|
cannot be created at this time;
|
|
|
|
- issue a management protocol set operation for
|
|
hpicfLinkTestNextIndex, supplying the same value
|
|
as obtained in the previous step;
|
|
|
|
- if the set operation succeeds, use the supplied
|
|
value as the hpicfLinkTestIndex of the new
|
|
link test; if the set operation fails, go back
|
|
to the first step and obtain a new value for
|
|
hpicfLinkTestNextIndex;
|
|
|
|
- issue a management protocol set operation to
|
|
create an instance of the hpicfLinkTestStatus
|
|
object setting its value to 'createAndGo' or
|
|
'createAndWait' (as specified in the description
|
|
of the RowStatus textual convention).
|
|
|
|
Note that the set of hpicfLinkTestNextIndex and the
|
|
instance of hpicfLinkTestStatus may occur in the
|
|
same set operation if desired."
|
|
::= { hpicfLinktest 1 }
|
|
|
|
hpicfLinkTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF HpicfLinkTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of in-progress link tests."
|
|
::= { hpicfLinktest 2 }
|
|
|
|
hpicfLinkTestEntry OBJECT-TYPE
|
|
SYNTAX HpicfLinkTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the table, containing information about a
|
|
single link test."
|
|
INDEX { hpicfLinkTestIndex }
|
|
::= { hpicfLinkTestTable 1 }
|
|
|
|
HpicfLinkTestEntry ::=
|
|
SEQUENCE {
|
|
hpicfLinkTestIndex Integer32,
|
|
hpicfLinkTestType INTEGER,
|
|
hpicfLinkTestAddress OCTET STRING,
|
|
hpicfLinkTestIfIndex Integer32,
|
|
hpicfLinkTestTimeout TimeInterval,
|
|
hpicfLinkTestRepetitions Integer32,
|
|
hpicfLinkTestAttempts Integer32,
|
|
hpicfLinkTestSuccesses Integer32,
|
|
hpicfLinkTestMinRespTime Integer32,
|
|
hpicfLinkTestMaxRespTime Integer32,
|
|
hpicfLinkTestTotalRespTime Integer32,
|
|
hpicfLinkTestOwner OwnerString,
|
|
hpicfLinkTestStatus RowStatus,
|
|
hpicfLinkTestDeleteMode INTEGER
|
|
}
|
|
|
|
hpicfLinkTestIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object uniquely identifies this
|
|
link test."
|
|
::= { hpicfLinkTestEntry 1 }
|
|
|
|
hpicfLinkTestType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
icmpEcho(1),
|
|
ieee8022Test(2),
|
|
ipxDiagnostic(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of test to run."
|
|
::= { hpicfLinkTestEntry 2 }
|
|
|
|
hpicfLinkTestAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4|6|10))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The destination address used for sending link test
|
|
packets, formatted according to the value of the
|
|
corresponding instance of hpicfLinkTestType. When
|
|
hpicfLinkTestType is equal to 'icmpEcho', this object
|
|
will be four octets long, and contain an IP address
|
|
in network byte order. When hpicfLinkTestType is
|
|
equal to 'ieee8022Test', this object will be six
|
|
octets long, and contain an IEEE MAC address in
|
|
canonical order. When hpicfLinkTestType is equal to
|
|
'ipxDiagnostic', this object will be ten octets long,
|
|
and will contain the IPX network number in network
|
|
byte order, followed by the IPX node number in
|
|
network byte order."
|
|
::= { hpicfLinkTestEntry 3 }
|
|
|
|
hpicfLinkTestIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local interface to send the link test packets
|
|
on. The value of this object must correspond to an
|
|
ifIndex value for an interface capable of supporting
|
|
the requested link test. The value 0 is used to
|
|
indicate that the agent should determine the
|
|
interface using local routing information."
|
|
DEFVAL { 0 }
|
|
::= { hpicfLinkTestEntry 4 }
|
|
|
|
hpicfLinkTestTimeout OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time interval over which a link test response
|
|
must be recieved, or the test is counted as failed."
|
|
DEFVAL { 100 } -- one second
|
|
::= { hpicfLinkTestEntry 5 }
|
|
|
|
hpicfLinkTestRepetitions OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of times that the agent should
|
|
send link test packets to the destination host."
|
|
DEFVAL { 1 }
|
|
::= { hpicfLinkTestEntry 6 }
|
|
|
|
hpicfLinkTestAttempts OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times we have sent link test packets
|
|
to the destination during the current test. This
|
|
object will start at zero when the corresponding
|
|
instance of hpicfLinkTestStatus is set to 'active'.
|
|
It will increment at the completion of each iteration
|
|
of the test until either it reaches the value of
|
|
hpicfLinkTestRepetitions, or the corresponding
|
|
instance of hpicfLinkTestStatus is set to a value
|
|
other than 'active'. Note that it is incremented
|
|
at the completion of each iteration, not when the
|
|
link test packet is sent, so that the number of
|
|
failures can be calculated accurately."
|
|
::= { hpicfLinkTestEntry 7 }
|
|
|
|
hpicfLinkTestSuccesses OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of times that we have received a response
|
|
to a link test packet during the current test. This
|
|
object will start at zero when the corresponding
|
|
instance of hpicfLinkTestStatus is set to 'active'.
|
|
It will increment each time the agent receives a
|
|
response from the destination of this test. Note
|
|
that the number of failed attempts is given by
|
|
hpicfLinkTestAttempts - hpicfLinkTestSuccesses."
|
|
::= { hpicfLinkTestEntry 8 }
|
|
|
|
hpicfLinkTestMinRespTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The shortest time (in milliseconds) between request
|
|
and response for all of the link tests that have been
|
|
attempted as part of this test."
|
|
::= { hpicfLinkTestEntry 9 }
|
|
|
|
hpicfLinkTestMaxRespTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The longest time (in milliseconds) between request
|
|
and response for all of the link tests that have been
|
|
attempted as part of this test."
|
|
::= { hpicfLinkTestEntry 10 }
|
|
|
|
hpicfLinkTestTotalRespTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sum of all of the response times (in
|
|
milliseconds) for all of the link tests that have
|
|
been attempted as part of this test. This value can
|
|
be used in conjunction with hpicfLinkTestSuccesses
|
|
to calculate the average response time."
|
|
::= { hpicfLinkTestEntry 11 }
|
|
|
|
hpicfLinkTestOwner OBJECT-TYPE
|
|
SYNTAX OwnerString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entity that configured this test and is
|
|
therefore using the resources assigned to it."
|
|
::= { hpicfLinkTestEntry 12 }
|
|
|
|
hpicfLinkTestStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this entry."
|
|
::= { hpicfLinkTestEntry 13 }
|
|
|
|
hpicfLinkTestDeleteMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
keepWhenDone(1),
|
|
destroyWhenDone(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the value of this object is 'keepWhenDone',
|
|
the associated instance of the hpicfLinkTestStatus
|
|
object will be changed to 'notInService' upon
|
|
completion of the test. It will then be timed out
|
|
by the agent after 5 minutes in the 'notInService'
|
|
state.
|
|
|
|
When the value of this object is 'destroyWhenDone',
|
|
the assocated instance of the hpicfLinkTestStatus
|
|
object will be changed to 'destroy' upon completion
|
|
of the test. This will remove the row from the
|
|
table immediately after the test completes."
|
|
DEFVAL { keepWhenDone }
|
|
::= { hpicfLinkTestEntry 14 }
|
|
|
|
-- Conformance information
|
|
|
|
hpicfLinkTestConformance
|
|
OBJECT IDENTIFIER ::= { hpicfLinkTestMib 1 }
|
|
|
|
hpicfLinkTestCompliances
|
|
OBJECT IDENTIFIER ::= { hpicfLinkTestConformance 1 }
|
|
hpicfLinkTestGroups
|
|
OBJECT IDENTIFIER ::= { hpicfLinkTestConformance 2 }
|
|
|
|
|
|
-- Compliance statements
|
|
|
|
hpicfLinkTestCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for ICF devices that
|
|
provide a connectivity test facility."
|
|
MODULE
|
|
MANDATORY-GROUPS { hpicfLinkTestGroup }
|
|
|
|
::= { hpicfLinkTestCompliances 1 }
|
|
|
|
hpicfLinkTestCompliance2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for ICF devices that
|
|
provide a connectivity test facility."
|
|
MODULE
|
|
MANDATORY-GROUPS { hpicfLinkTestGroup2 }
|
|
|
|
::= { hpicfLinkTestCompliances 2 }
|
|
|
|
|
|
-- Units of conformance
|
|
|
|
hpicfLinkTestGroup OBJECT-GROUP
|
|
OBJECTS { hpicfLinkTestNextIndex,
|
|
hpicfLinkTestType,
|
|
hpicfLinkTestAddress,
|
|
hpicfLinkTestIfIndex,
|
|
hpicfLinkTestTimeout,
|
|
hpicfLinkTestRepetitions,
|
|
hpicfLinkTestAttempts,
|
|
hpicfLinkTestSuccesses,
|
|
hpicfLinkTestMinRespTime,
|
|
hpicfLinkTestMaxRespTime,
|
|
hpicfLinkTestTotalRespTime,
|
|
hpicfLinkTestOwner,
|
|
hpicfLinkTestStatus
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A collection of objects for initiating and
|
|
monitoring network connectivity tests on ICF
|
|
devices."
|
|
::= { hpicfLinkTestGroups 1 }
|
|
|
|
hpicfLinkTestGroup2 OBJECT-GROUP
|
|
OBJECTS { hpicfLinkTestNextIndex,
|
|
hpicfLinkTestType,
|
|
hpicfLinkTestAddress,
|
|
hpicfLinkTestIfIndex,
|
|
hpicfLinkTestTimeout,
|
|
hpicfLinkTestRepetitions,
|
|
hpicfLinkTestAttempts,
|
|
hpicfLinkTestSuccesses,
|
|
hpicfLinkTestMinRespTime,
|
|
hpicfLinkTestMaxRespTime,
|
|
hpicfLinkTestTotalRespTime,
|
|
hpicfLinkTestOwner,
|
|
hpicfLinkTestStatus,
|
|
hpicfLinkTestDeleteMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A collection of objects for initiating and
|
|
monitoring network connectivity tests on ICF
|
|
devices."
|
|
::= { hpicfLinkTestGroups 2 }
|
|
|
|
|
|
END
|
|
|