-- %DNP% $Id: ERICSSON-ROUTER-ENVMON-MIB.my,v 1.2.4.4.120.5 2011/05/05 18:15:55 chiachun Exp $
-- %DNP% $Source: /cvsroot/pkt/sw/se/xc/bsd/config/snmp/mibs/ERICSSON-ROUTER-ENVMON-MIB.my,v $
-- *****************************************************************
-- ERICSSON-ROUTER-ENVMON-MIB Environmental Monitor MIB
--
-- Copyright (c) 1999-2007, 2010-2011, 2015 Ericsson AB
-- All rights reserved.
--
-- *****************************************************************
ERICSSON-ROUTER-ENVMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Unsigned32,
Integer32
FROM SNMPv2-SMI
DisplayString,
TruthValue,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
entPhysicalIndex
FROM ENTITY-MIB
eriRouterMgmt
FROM ERICSSON-ROUTER-SMI;
eriRouterEnvMonMIB MODULE-IDENTITY
LAST-UPDATED "201501141800Z" -- Jan 14, 2015
ORGANIZATION "Ericsson AB."
CONTACT-INFO
" Ericsson AB.
Postal: 100 Headquarters Dr.
San Jose, CA 95134
USA
Phone: +1 408 750 5000
Fax: +1 408 750 5599
"
DESCRIPTION
"The MIB used to genericially manage Environmental
Monitor functionality on network devices."
REVISION "201501141800Z" -- Jan 14, 2015
DESCRIPTION
"Updated RBN/rbn/Rbn as ERICSSON-ROUTER/eriRouter/EriRouter
to migrate RBN MIB to ERICSSON MIB."
REVISION "201210030000Z" -- October 3, 2012
DESCRIPTION
"Removed DISPLAY-HINT from EriRouterVoltage and EriRouterFanSpeed."
REVISION "201101191800Z" -- Jan 19, 2011
DESCRIPTION
"Update CONTACT-INFO & ORGANIZATION. "
REVISION "201011110000Z" -- Nov 11, 2010
DESCRIPTION
"Add new Table eriRouterEntityTempSensorTable. This will display
the TempSensor Details for all the entities. "
REVISION "200601160000Z" -- January 16, 2006
DESCRIPTION
"Add textual convention EriRouterFanSpeed. Add new OIDs:
eriRouterFanUnitID
eriRouterFanUnitDescr
eriRouterFanSpeedCurrent
eriRouterEnvMonFanSpeedObjectGroup
eriRouterEnvMonMIBComplianceV4
"
REVISION "200206050000Z" -- June 5, 2002
DESCRIPTION
"Update/correct CONTACT-INFO. Fix syntax errors on IMPORTS list,
ranges on Integer32, and size for DisplayString types.
Restore the incorrectly deprecated OIDs to current, since they
are still supported."
REVISION "200107250000Z" -- July 25, 2001
DESCRIPTION
"Added new OIDs:
eriRouterFanStatus
eriRouterPowerStatus
eriRouterFanStatusChange
eriRouterPowerStatusChange
eriRouterEnvMonMIBObjectGroupV2
eriRouterEnvMonMIBNotificationGroupV2
eriRouterEnvMonMIBComplianceV3
Deprecated the OIDs:
eriRouterFanFail
eriRouterPowerFail
eriRouterFanFailChange
eriRouterPowerFailChange
eriRouterEnvMonMIBObjectGroup
eriRouterEnvMonMIBNotificationGroup
eriRouterEnvMonMIBComplianceV2
"
REVISION "200004240000Z" -- May 24, 2000
DESCRIPTION
"Added voltage and temperature sensor tables."
REVISION "199903100000Z" -- Mar 10, 1999
DESCRIPTION
"Initial version."
::= { eriRouterMgmt 4 }
eriRouterEnvMonMIBNotifications OBJECT IDENTIFIER
::= { eriRouterEnvMonMIB 0 }
eriRouterEnvMonMIBObjects OBJECT IDENTIFIER
::= { eriRouterEnvMonMIB 1 }
eriRouterEnvMonMIBConformance OBJECT IDENTIFIER
::= { eriRouterEnvMonMIB 2 }
-- Textual Conventions
EriRouterVoltage ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a voltage value. The value is millivolts.
For example, a voltage of 5.5V would be represented
by the value 5500."
SYNTAX Unsigned32 (0..50000)
EriRouterTemperature ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"Represents a temperature, in degrees Celsius. In the
unlikely event that the temperature to be reported is
less than 0 degrees Celsius, a value of 0 will be
used. Likewise, if the temperature is greater than
100, a value of 100 will be used."
SYNTAX Unsigned32 (0..100)
EriRouterFanSpeed ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents a fan speed value in units of Revolutions Per
Minute(RPM)."
SYNTAX Unsigned32
-- MIB Objects
eriRouterFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan test point.
Note that there is not necessarily a one-to-one
relationship between fan test points and fan
assemblies; a single test point may be used to
monitor the status of multiple fans."
::= { eriRouterEnvMonMIBObjects 1 }
eriRouterFanStatusEntry OBJECT-TYPE
SYNTAX EriRouterFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan test point"
INDEX { eriRouterFanIndex }
::= { eriRouterFanStatusTable 1 }
EriRouterFanStatusEntry ::= SEQUENCE {
eriRouterFanIndex Integer32,
eriRouterFanDescr DisplayString,
eriRouterFanFail TruthValue,
eriRouterFanStatus INTEGER
}
eriRouterFanIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a fan test point."
::= { eriRouterFanStatusEntry 1 }
eriRouterFanDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a fan test point. If an instance of
this object is associated with a single fan assembly,
then the value of this object should be the same as the
name by which the assembly is normally referenced. If
an instance is associated with multiple fan assemblies,
then the value of this object should contain the names
of all of the fan assemblies being monitored."
::= { eriRouterFanStatusEntry 2 }
eriRouterFanFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value true, then a fan monitored
by the test point has failed. If an instance of
this object has the value false, then the fan (or fans)
monitored by the test point are operational."
::= { eriRouterFanStatusEntry 3 }
eriRouterFanStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a fan test point. If an instance of
this object has the value normal, then the fan (or
fans) monitored by the test point is operational. If
an instance of this object has the value failed, then
the fan (or fans) monitored by the test point has
failed. If an instance of this object has the value
absent, then the fan (or fans) monitored by this test
point is not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the fan (or fans)."
::= { eriRouterFanStatusEntry 4 }
eriRouterPowerStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per power test point.
Note that there is not necessarily a one-to-one
relationship between power test points and power
supply assemblies; a single test point may be used
to monitor the status of multiple power supplies."
::= { eriRouterEnvMonMIBObjects 2 }
eriRouterPowerStatusEntry OBJECT-TYPE
SYNTAX EriRouterPowerStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular power test point"
INDEX { eriRouterPowerIndex }
::= { eriRouterPowerStatusTable 1 }
EriRouterPowerStatusEntry ::= SEQUENCE {
eriRouterPowerIndex Integer32,
eriRouterPowerDescr DisplayString,
eriRouterPowerFail TruthValue,
eriRouterPowerStatus INTEGER
}
eriRouterPowerIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index of a power test point."
::= { eriRouterPowerStatusEntry 1 }
eriRouterPowerDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a power supply test point. If an
instance of this object is associated with a single
power supply assembly, then the value of this object
should be the same as the name by which the assembly
is normally referenced. If an instance is associated
with multiple power supply assemblies, then the value
of this object should contain the names of all of the
power supply assemblies being monitored."
::= { eriRouterPowerStatusEntry 2 }
eriRouterPowerFail OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value true, then a power supply
monitored by the test point has failed. If an instance
of this object has the value false, then the power
supply (or supplies) monitored by the test point are
operational."
::= { eriRouterPowerStatusEntry 3 }
eriRouterPowerStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
failed(2),
absent(3),
unknown(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of a power test point. If an instance of
this object has the value normal, then the power
supply (or supplies) monitored by the test point is
operational. If an instance of this object has the
value failed, then the power supply (or supplies)
monitored by the test point has failed. If an instance
of this object has the value absent, then the power
supply (or supplies) monitored by this test point is
not present. If an instance of this object has
the value unknown, then the test point is unable to
monitor the power supply (or supplies)."
::= { eriRouterPowerStatusEntry 4 }
eriRouterVoltageSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per voltage test point.
Each physical entity (e.g. cards) in the system may
contain zero or more voltage test points."
::= { eriRouterEnvMonMIBObjects 3 }
eriRouterVoltageSensorEntry OBJECT-TYPE
SYNTAX EriRouterVoltageSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular voltage test point."
INDEX { entPhysicalIndex, eriRouterVoltageIndex }
::= { eriRouterVoltageSensorTable 1 }
EriRouterVoltageSensorEntry ::= SEQUENCE {
eriRouterVoltageIndex Integer32,
eriRouterVoltageDescr DisplayString,
eriRouterVoltageDesired EriRouterVoltage,
eriRouterVoltageCurrent EriRouterVoltage
}
eriRouterVoltageIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
voltage test point on a particular physical entity.
Index values for different test points are not
necessarily contiguous."
::= { eriRouterVoltageSensorEntry 1 }
eriRouterVoltageDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a voltage test point. Typically
an instance of this object will hold a user-friendly
description of the physical entity and the level of
voltage being monitored by this test point."
::= { eriRouterVoltageSensorEntry 2 }
eriRouterVoltageDesired OBJECT-TYPE
SYNTAX EriRouterVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The desired voltage level for this test point. If
the monitored voltage level (eriRouterVoltageCurrent) is
equal to this value, then the system is performing
as designed."
::= { eriRouterVoltageSensorEntry 3 }
eriRouterVoltageCurrent OBJECT-TYPE
SYNTAX EriRouterVoltage
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current voltage level at this test point."
::= { eriRouterVoltageSensorEntry 4 }
eriRouterCpuTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains one row per CPU temperature
sensor. Each physical entity in the system may have
zero or more CPUs. Each of those CPUs that has a
temperature sensor will show up here."
::= { eriRouterEnvMonMIBObjects 4 }
eriRouterCpuTempSensorEntry OBJECT-TYPE
SYNTAX EriRouterCpuTempSensorEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Information about a particular CPU temperature test
point."
INDEX { entPhysicalIndex, eriRouterCpuTempIndex }
::= { eriRouterCpuTempSensorTable 1 }
EriRouterCpuTempSensorEntry ::= SEQUENCE {
eriRouterCpuTempIndex Integer32,
eriRouterCpuTempDescr DisplayString,
eriRouterCpuTempCurrent EriRouterTemperature
}
eriRouterCpuTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An arbitrary value which uniquely identifies a CPU on
a particular physical entity. Index values for
different CPUs are not necessarily contiguous."
::= { eriRouterCpuTempSensorEntry 1 }
eriRouterCpuTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The description of a CPU temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
and a description of the CPU being monitored by this
test point."
::= { eriRouterCpuTempSensorEntry 2 }
eriRouterCpuTempCurrent OBJECT-TYPE
SYNTAX EriRouterTemperature
UNITS "degrees"
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The current temperature of this CPU."
::= { eriRouterCpuTempSensorEntry 3 }
eriRouterFanSpeedTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per fan unit within a fan
test point."
::= { eriRouterEnvMonMIBObjects 5 }
eriRouterFanSpeedEntry OBJECT-TYPE
SYNTAX EriRouterFanSpeedEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular fan unit within a fan
test point."
INDEX { eriRouterFanIndex, eriRouterFanUnitID }
::= { eriRouterFanSpeedTable 1 }
EriRouterFanSpeedEntry ::= SEQUENCE {
eriRouterFanUnitID Integer32,
eriRouterFanUnitDescr DisplayString,
eriRouterFanSpeedCurrent EriRouterFanSpeed
}
eriRouterFanUnitID OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the fan identification number that describes the
specific location of the fan unit within a fan test point."
::= { eriRouterFanSpeedEntry 1 }
eriRouterFanUnitDescr OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of the fan unit within a fan test point."
::= { eriRouterFanSpeedEntry 2 }
eriRouterFanSpeedCurrent OBJECT-TYPE
SYNTAX EriRouterFanSpeed
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current speed of this fan unit."
::= { eriRouterFanSpeedEntry 3 }
eriRouterEntityTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF EriRouterEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains one row per temperature
sensor on the physical entity."
::= { eriRouterEnvMonMIBObjects 6 }
eriRouterEntityTempSensorEntry OBJECT-TYPE
SYNTAX EriRouterEntityTempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information about a particular temperature test
point."
INDEX { entPhysicalIndex, eriRouterEntityTempIndex }
::= { eriRouterEntityTempSensorTable 1 }
EriRouterEntityTempSensorEntry ::= SEQUENCE {
eriRouterEntityTempIndex Integer32,
eriRouterEntityTempDescr DisplayString,
eriRouterEntityTempCurrent EriRouterTemperature
}
eriRouterEntityTempIndex OBJECT-TYPE
SYNTAX Integer32(1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary value which uniquely identifies a
particular physical entity. Index values are
not necessarily contiguous."
::= { eriRouterEntityTempSensorEntry 1 }
eriRouterEntityTempDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The description of a temperature test
point. Typically an instance of this object will hold
a user-friendly description of the physical entity
being monitored by this test point."
::= { eriRouterEntityTempSensorEntry 2 }
eriRouterEntityTempCurrent OBJECT-TYPE
SYNTAX EriRouterTemperature
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current temperature of this entity in degrees Celsius."
::= { eriRouterEntityTempSensorEntry 3 }
-- Notifications
eriRouterFanFailChange NOTIFICATION-TYPE
OBJECTS { eriRouterFanFail }
STATUS deprecated
DESCRIPTION
"A eriRouterFanFailChange notification signifies
that the value of an instance of eriRouterFanFail
has changed."
::= { eriRouterEnvMonMIBNotifications 1 }
eriRouterPowerFailChange NOTIFICATION-TYPE
OBJECTS { eriRouterPowerFail }
STATUS deprecated
DESCRIPTION
"A eriRouterPowerFailChange notification signifies
that the value of an instance of eriRouterPowerFail
has changed"
::= { eriRouterEnvMonMIBNotifications 2 }
eriRouterFanStatusChange NOTIFICATION-TYPE
OBJECTS { eriRouterFanStatus }
STATUS current
DESCRIPTION
"A eriRouterFanStatusChange notification signifies
that the value of an instance of eriRouterFanStatus
has changed."
::= { eriRouterEnvMonMIBNotifications 3 }
eriRouterPowerStatusChange NOTIFICATION-TYPE
OBJECTS { eriRouterPowerStatus }
STATUS current
DESCRIPTION
"A eriRouterPowerStatusChange notification signifies
that the value of an instance of eriRouterPowerStatus
has changed"
::= { eriRouterEnvMonMIBNotifications 4 }
-- Conformance Statements
eriRouterEnvMonMIBGroups OBJECT IDENTIFIER
::= { eriRouterEnvMonMIBConformance 1 }
eriRouterEnvMonMIBCompliances OBJECT IDENTIFIER
::= { eriRouterEnvMonMIBConformance 2 }
eriRouterEnvMonMIBObjectGroup OBJECT-GROUP
OBJECTS { eriRouterFanDescr, eriRouterFanFail,
eriRouterPowerDescr, eriRouterPowerFail
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 1 }
eriRouterEnvMonMIBNotificationGroup NOTIFICATION-GROUP
NOTIFICATIONS { eriRouterFanFailChange,
eriRouterPowerFailChange
}
STATUS deprecated
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { eriRouterEnvMonMIBGroups 2 }
eriRouterEnvMonVoltageObjectGroup OBJECT-GROUP
OBJECTS { eriRouterVoltageDescr, eriRouterVoltageDesired,
eriRouterVoltageCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing voltage
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 3 }
eriRouterEnvMonTempObjectGroup OBJECT-GROUP
OBJECTS { eriRouterCpuTempDescr, eriRouterCpuTempCurrent
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing temperature
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 4 }
eriRouterEnvMonMIBObjectGroupV2 OBJECT-GROUP
OBJECTS { eriRouterFanDescr, eriRouterFanStatus,
eriRouterPowerDescr, eriRouterPowerStatus
}
STATUS current
DESCRIPTION
"A collection of objects providing
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 5 }
eriRouterEnvMonMIBNotificationGroupV2 NOTIFICATION-GROUP
NOTIFICATIONS { eriRouterFanStatusChange,
eriRouterPowerStatusChange
}
STATUS current
DESCRIPTION
"A collection of notifications providing
fan and power environmental monitor information."
::= { eriRouterEnvMonMIBGroups 6 }
eriRouterEnvMonFanSpeedObjectGroup OBJECT-GROUP
OBJECTS { eriRouterFanUnitDescr, eriRouterFanSpeedCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 7 }
eriRouterEnvMonEntityObjectGroup OBJECT-GROUP
OBJECTS { eriRouterEntityTempDescr, eriRouterEntityTempCurrent
}
STATUS current
DESCRIPTION
"A collection of objects providing fan speed
environmental monitor information."
::= { eriRouterEnvMonMIBGroups 8 }
eriRouterEnvMonMIBCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP eriRouterEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
::= { eriRouterEnvMonMIBCompliances 1 }
eriRouterEnvMonMIBComplianceV2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP eriRouterEnvMonMIBObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonMIBNotificationGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP eriRouterEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { eriRouterEnvMonMIBCompliances 2 }
eriRouterEnvMonMIBComplianceV3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP eriRouterEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP eriRouterEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
::= { eriRouterEnvMonMIBCompliances 3 }
eriRouterEnvMonMIBComplianceV4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP eriRouterEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP eriRouterEnvMonTempObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system temperatures."
GROUP eriRouterEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
::= { eriRouterEnvMonMIBCompliances 4 }
eriRouterEnvMonMIBComplianceV5 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the EnvMon MIB"
MODULE -- this module
GROUP eriRouterEnvMonMIBObjectGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonMIBNotificationGroupV2
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities"
GROUP eriRouterEnvMonVoltageObjectGroup
DESCRIPTION
"This group is mandatory for devices which are capable
of sensing system voltages."
GROUP eriRouterEnvMonFanSpeedObjectGroup
DESCRIPTION
"This group is mandatory for SNMP entities which are
capable of sensing fan speeds."
GROUP eriRouterEnvMonEntityObjectGroup
DESCRIPTION
"This group is mandatory for devices which contain
Environmental Monitoring capabilities, also applicable to SSE
card and disks"
::= { eriRouterEnvMonMIBCompliances 5 }
END