- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
542 lines
18 KiB
Text
542 lines
18 KiB
Text
MARVELL-POE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: Marvell LOCALIZATION ROS
|
|
-- This Private MIB is enhancement for rfc3621.txt - Power Ethernet Mib
|
|
-- Version: 7.50
|
|
-- Date: 28 Nov 2005
|
|
|
|
IMPORTS
|
|
rnd FROM RADLAN-MIB
|
|
DisplayString, TruthValue FROM SNMPv2-TC
|
|
InterfaceIndex FROM IF-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32 FROM SNMPv2-SMI;
|
|
|
|
|
|
rlPoe MODULE-IDENTITY
|
|
LAST-UPDATED "200911260000Z"
|
|
ORGANIZATION "Marvell."
|
|
CONTACT-INFO
|
|
"Marvell.com"
|
|
DESCRIPTION
|
|
"Add a new field in the PoE MIB to indicate Max power allocation allowed"
|
|
REVISION "201006020000Z"
|
|
DESCRIPTION
|
|
"The private MIB module definition for Power Over Ethernet."
|
|
REVISION "200911260000Z"
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { rnd 108 }
|
|
|
|
RlPoeType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "PoE types:
|
|
1 - none: no PoE, unknown type;
|
|
2 - PoE: Standard AF PoE
|
|
3 - PoE Plus: Standard AT PoE
|
|
4 - 60 W: 60W poe port "
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
poe(2),
|
|
poeplus(3),
|
|
poe60w(4)
|
|
}
|
|
|
|
rlPethPsePortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing additional information for Power Over Ethernet ports."
|
|
::= {rlPoe 1 }
|
|
|
|
rlPethPsePortEntry OBJECT-TYPE
|
|
SYNTAX RlPethPsePortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlPethPsePortTable."
|
|
INDEX { rlPethPsePortGroupIndex , rlPethPsePortIndex }
|
|
::= {rlPethPsePortTable 1 }
|
|
|
|
RlPethPsePortEntry ::= SEQUENCE {
|
|
rlPethPsePortGroupIndex INTEGER,
|
|
rlPethPsePortIndex INTEGER,
|
|
rlPethPsePortOutputVoltage INTEGER,
|
|
rlPethPsePortOutputCurrent INTEGER,
|
|
rlPethPsePortOutputPower INTEGER,
|
|
rlPethPsePortPowerLimit INTEGER,
|
|
rlPethPsePortStatus INTEGER,
|
|
rlPethPsePortStatusDescription DisplayString,
|
|
rlPethPsePortOperPowerLimit INTEGER,
|
|
rlPethPsePortTimeRangeName DisplayString,
|
|
rlPethPsePortOperStatus TruthValue,
|
|
rlPethPsePortMaxPowerAllocAllowed INTEGER,
|
|
rlPethPsePortSupportPoeType RlPoeType,
|
|
rlPethPsePortLinkPartnerPoeType RlPoeType,
|
|
rlPethPsePortFourPairForced INTEGER,
|
|
rlPethPsePortFourPairEnabled INTEGER,
|
|
rlPethPsePortNegotiationAllocatedPower INTEGER,
|
|
rlPethPsePortNegotiationProtocolOwner INTEGER
|
|
}
|
|
|
|
rlPethPsePortGroupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group
|
|
containing the port to which a power Ethernet PSE is
|
|
connected. Group means box in the stack, module in a
|
|
rack and the value 1 MUST be used for non-modular devices.
|
|
Furthermore, the same value MUST be used in this variable,
|
|
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
|
to refer to a given box in a stack or module in the rack."
|
|
::= { rlPethPsePortEntry 1 }
|
|
|
|
rlPethPsePortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the power Ethernet PSE
|
|
port within group pethPsePortGroupIndex to which the
|
|
power Ethernet PSE entry is connected."
|
|
::= { rlPethPsePortEntry 2 }
|
|
|
|
rlPethPsePortOutputVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates on the output voltage level in milli volts from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 3 }
|
|
|
|
rlPethPsePortOutputCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates on the output current level in milli amper from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 4 }
|
|
|
|
rlPethPsePortOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates on the output power level in milli watts from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 5 }
|
|
|
|
rlPethPsePortPowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates on the user configured power level in milli watts which is available from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 6 }
|
|
|
|
rlPethPsePortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates on the hardware status of rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 7 }
|
|
|
|
rlPethPsePortStatusDescription OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..80))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the description of the hardware status of rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 8 }
|
|
|
|
rlPethPsePortOperPowerLimit OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the maximum power level in milli watts which is available from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 9 }
|
|
|
|
rlPethPsePortTimeRangeName OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to bind PoE port to time range."
|
|
::= { rlPethPsePortEntry 10 }
|
|
|
|
rlPethPsePortOperStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Read-Only variable indicates PoE port current status affected by time range active/inactive and admin status."
|
|
::= { rlPethPsePortEntry 11 }
|
|
|
|
rlPethPsePortMaxPowerAllocAllowed OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the maximum power allocation allowed per port (including wire power loses) in milli-watts which is available from rlPethPsePortIndex."
|
|
::= { rlPethPsePortEntry 12 }
|
|
|
|
rlPethPsePortSupportPoeType OBJECT-TYPE
|
|
SYNTAX RlPoeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the supported type of the PoE port"
|
|
::= { rlPethPsePortEntry 13 }
|
|
|
|
rlPethPsePortLinkPartnerPoeType OBJECT-TYPE
|
|
SYNTAX RlPoeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the link partner PoE type."
|
|
::= { rlPethPsePortEntry 14 }
|
|
|
|
rlPethPsePortFourPairForced OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
forcedEnable(0),
|
|
forcedDisable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable enabled the spare pair ALT_B in 60W port to force 4 pair enable."
|
|
::= { rlPethPsePortEntry 15 }
|
|
|
|
rlPethPsePortFourPairEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fourPairEnable(1),
|
|
fourPairDisable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates that spare pair ALT_B is enable."
|
|
::= { rlPethPsePortEntry 16 }
|
|
|
|
rlPethPsePortNegotiationAllocatedPower OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the power allocation in milli watts from power negotiation"
|
|
::= { rlPethPsePortEntry 17 }
|
|
|
|
rlPethPsePortNegotiationProtocolOwner OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
protocolOwnerNone(0),
|
|
protocolOwnerCDP(1),
|
|
protocolOwnerLLDP(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the protocol owner on power management negotiation protocol"
|
|
::= { rlPethPsePortEntry 18 }
|
|
|
|
rlPethMainPseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing additional read - only information for Power Over Ethernet."
|
|
::= {rlPoe 2 }
|
|
|
|
rlPethMainPseEntry OBJECT-TYPE
|
|
SYNTAX RlPethMainPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlPethMainPseTable."
|
|
INDEX { rlPethMainPseGroupIndex }
|
|
::= {rlPethMainPseTable 1 }
|
|
|
|
RlPethMainPseEntry ::= SEQUENCE {
|
|
rlPethMainPseGroupIndex INTEGER,
|
|
rlPethMainPseSwVersion DisplayString,
|
|
rlPethMainPseHwVersion DisplayString,
|
|
rlPethMainPseHwType INTEGER,
|
|
rlPethMainPsePowerGuardBand INTEGER
|
|
|
|
}
|
|
|
|
rlPethMainPseGroupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group
|
|
containing the port to which a power Ethernet PSE is
|
|
connected. Group means box in the stack, module in a
|
|
rack and the value 1 MUST be used for non-modular devices.
|
|
Furthermore, the same value MUST be used in this variable,
|
|
pethMainPseGroupIndex, and pethNotificationControlGroupIndex
|
|
to refer to a given box in a stack or module in the rack."
|
|
::= { rlPethMainPseEntry 1 }
|
|
|
|
rlPethMainPseSwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the MCU SW version."
|
|
::= { rlPethMainPseEntry 2 }
|
|
|
|
rlPethMainPseHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(0..20))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the MCU HW version."
|
|
::= { rlPethMainPseEntry 3 }
|
|
|
|
rlPethMainPseHwType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enhanced(1),
|
|
plus(2),
|
|
auto(3),
|
|
nonPoe(4),
|
|
enhancedPlus(5),
|
|
poe60w(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the MCU HW type (enhanced, plus, none)."
|
|
::= { rlPethMainPseEntry 4 }
|
|
|
|
rlPethMainPsePowerGuardBand OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the guard band in [W] for not connecting
|
|
additional ports."
|
|
::= { rlPethMainPseEntry 5 }
|
|
|
|
rlPethPowerPseTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPethPowerPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing additional read-write information for Power Over Ethernet - PSE side."
|
|
::= {rlPoe 3 }
|
|
|
|
rlPethPowerPseEntry OBJECT-TYPE
|
|
SYNTAX RlPethPowerPseEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlPethPowerPseTable."
|
|
INDEX { rlPethPowerPseGroupIndex }
|
|
::= {rlPethPowerPseTable 1 }
|
|
|
|
RlPethPowerPseEntry ::= SEQUENCE {
|
|
rlPethPowerPseGroupIndex INTEGER,
|
|
rlPethPowerPsePower INTEGER,
|
|
rlPethPowerPseRpsPower INTEGER,
|
|
rlPethPowerPsePowerManagementMode INTEGER,
|
|
rlPethPowerPsedisconnectMethod INTEGER,
|
|
rlPethPowerPseTemperatureSensor INTEGER,
|
|
rlPethPowerPseInrushTestEnabled INTEGER,
|
|
rlPethPowerPseLegacyDisabled INTEGER
|
|
}
|
|
|
|
rlPethPowerPseGroupIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the group
|
|
containing the port to which a power Ethernet PSE is
|
|
connected. Group means box in the stack, module in a
|
|
rack and the value 1 MUST be used for non-modular devices.
|
|
Furthermore, the same value MUST be used in this variable,
|
|
PethPowerPseGroupIndex, and pethNotificationControlGroupIndex
|
|
to refer to a given box in a stack or module in the rack."
|
|
::= { rlPethPowerPseEntry 1 }
|
|
|
|
|
|
-- depricated
|
|
rlPethPowerPsePower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
ps1(1),
|
|
ps2(2),
|
|
ps3(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the maximum power in [W] supplied by PSE."
|
|
::= { rlPethPowerPseEntry 2 }
|
|
|
|
-- depricated
|
|
rlPethPowerPseRpsPower OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
rps1(1),
|
|
rps2(2),
|
|
rps3(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the maximum power in [W] supplied by PSE + RPS."
|
|
::= { rlPethPowerPseEntry 3 }
|
|
|
|
rlPethPowerPsePowerManagementMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
portlimit(0),
|
|
classlimit(5),
|
|
maxlimit(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies power management mode."
|
|
::= { rlPethPowerPseEntry 4 }
|
|
|
|
rlPethPowerPsedisconnectMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
lowestpriority(0),
|
|
nextport(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies disconnect method. "
|
|
::= { rlPethPowerPseEntry 5 }
|
|
|
|
rlPethPowerPseTemperatureSensor OBJECT-TYPE
|
|
SYNTAX INTEGER (-200..200)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies the pd temperature sensor. "
|
|
::= { rlPethPowerPseEntry 6 }
|
|
|
|
rlPethPowerPseInrushTestEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies if HW inrush test will be disabled.
|
|
by default HW inrush test is enabled."
|
|
::= { rlPethPowerPseEntry 7 }
|
|
|
|
rlPethPowerPseLegacyDisabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
disabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable identifies poe Legacy global configuration mode"
|
|
::= { rlPethPowerPseEntry 8 }
|
|
|
|
|
|
--rlPethPdPortTable
|
|
|
|
rlPethPdPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RlPethPdPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The table listing additional read-write information for Power Over Ethernet - PD side."
|
|
::= {rlPoe 4 }
|
|
|
|
rlPethPdPortEntry OBJECT-TYPE
|
|
SYNTAX RlPethPdPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the rlPethPdPortTable."
|
|
INDEX { rlPethPdPortIndex }
|
|
::= {rlPethPdPortTable 1}
|
|
|
|
RlPethPdPortEntry ::= SEQUENCE {
|
|
rlPethPdPortIndex InterfaceIndex,
|
|
rlPethPdPortSupportPoeType RlPoeType,
|
|
rlPethPdPortOperPoeType RlPoeType,
|
|
rlPethPdPortPowerRequest Unsigned32,
|
|
rlPethPdPortPowerAvailable Unsigned32,
|
|
rlPethPdPortForcedMode RlPoeType,
|
|
rlPethPdPortNegotiationProtocolOwner INTEGER
|
|
}
|
|
|
|
rlPethPdPortIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable uniquely identifies the power Ethernet PD
|
|
port within group rlPethPdPortGroupIndex to which the
|
|
power Ethernet PSE entry is connected."
|
|
::= { rlPethPdPortEntry 1 }
|
|
|
|
rlPethPdPortSupportPoeType OBJECT-TYPE
|
|
SYNTAX RlPoeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the PoE type of the PD port (AF/AT/60W)"
|
|
::= { rlPethPdPortEntry 2 }
|
|
|
|
rlPethPdPortOperPoeType OBJECT-TYPE
|
|
SYNTAX RlPoeType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the operational PoE status of the PD port"
|
|
::= { rlPethPdPortEntry 3 }
|
|
|
|
rlPethPdPortPowerRequest OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the requested power the PD port request from the PSE in mili-Watts"
|
|
::= { rlPethPdPortEntry 4 }
|
|
|
|
rlPethPdPortPowerAvailable OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the available power the PSE port offers to the PD port in mili-Watts"
|
|
::= { rlPethPdPortEntry 5 }
|
|
|
|
rlPethPdPortForcedMode OBJECT-TYPE
|
|
SYNTAX RlPoeType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the powered PD port forced mode"
|
|
::= { rlPethPdPortEntry 6 }
|
|
|
|
rlPethPdPortNegotiationProtocolOwner OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
protocolOwnerNone(0),
|
|
protocolOwnerCDP(1),
|
|
protocolOwnerLLDP(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the protocol owner on power management negotiation protocol"
|
|
::= { rlPethPdPortEntry 7 }
|
|
|
|
END
|
|
|