- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
564 lines
17 KiB
Text
564 lines
17 KiB
Text
ELTEX-MES-PHYSICAL-DESCRIPTION-MIB DEFINITIONS ::= BEGIN
|
|
-- Version: 2.3
|
|
-- Date: 04-Aug-2021
|
|
|
|
IMPORTS
|
|
OBJECT-TYPE, MODULE-IDENTITY, TimeTicks,
|
|
NOTIFICATION-TYPE, Integer32 FROM SNMPv2-SMI
|
|
DisplayString, PhysAddress, RowStatus, TruthValue FROM SNMPv2-TC
|
|
JackType FROM MAU-MIB
|
|
InterfaceIndexOrZero,ifIndex,InterfaceIndex FROM IF-MIB
|
|
eltMes FROM ELTEX-MES
|
|
rlPhdUnitGenParamEntry, rlCascadeEntry, rlCascadeAdminEntry
|
|
FROM RADLAN-Physicaldescription-MIB
|
|
;
|
|
|
|
eltMesPhysicalDescription MODULE-IDENTITY
|
|
LAST-UPDATED "202108040000Z"
|
|
ORGANIZATION "Eltex Ltd."
|
|
CONTACT-INFO
|
|
"eltex.nsk.ru"
|
|
DESCRIPTION
|
|
"The private MIB module definition for physical
|
|
device configuration and information."
|
|
|
|
REVISION "202108040000Z"
|
|
DESCRIPTION
|
|
"Added eltCascadeAdminTable, added field eltCascadeFecOperMode
|
|
to eltCascadeEntry."
|
|
|
|
REVISION "201804240000Z"
|
|
DESCRIPTION
|
|
"Added eltPhdTransceiverThresholdTable."
|
|
|
|
REVISION "201711110000Z"
|
|
DESCRIPTION
|
|
"Added fields eltPhdTransceiverInfoPartNumber and
|
|
eltPhdTransceiverInfoVendorRev to eltPhdTransceiverInfoTable"
|
|
|
|
REVISION "201509140000Z"
|
|
DESCRIPTION
|
|
"Added eltPhdUnitGenParamTable."
|
|
|
|
REVISION "201303210000Z"
|
|
DESCRIPTION
|
|
"Initial revision."
|
|
::= { eltMes 53 }
|
|
|
|
eltMesPhdTransceiver OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 1 }
|
|
|
|
eltPhdTransceiverInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltPhdTransceiverInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table show the information of transceiver on interface."
|
|
::= { eltMesPhdTransceiver 1 }
|
|
|
|
eltPhdTransceiverInfoEntry OBJECT-TYPE
|
|
SYNTAX EltPhdTransceiverInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of the eltPhdTransceiverInfoTable."
|
|
INDEX { ifIndex }
|
|
::= { eltPhdTransceiverInfoTable 1 }
|
|
|
|
EltPhdTransceiverInfoEntry ::=
|
|
SEQUENCE {
|
|
eltPhdTransceiverInfoConnectorType INTEGER,
|
|
eltPhdTransceiverInfoType INTEGER,
|
|
eltPhdTransceiverInfoComplianceCode OCTET STRING,
|
|
eltPhdTransceiverInfoWaveLength Integer32,
|
|
eltPhdTransceiverInfoVendorName OCTET STRING,
|
|
eltPhdTransceiverInfoSerialNumber OCTET STRING,
|
|
eltPhdTransceiverInfoFiberDiameterType INTEGER,
|
|
eltPhdTransceiverInfoTransferDistance Integer32,
|
|
eltPhdTransceiverInfoDiagnostic TruthValue,
|
|
eltPhdTransceiverInfoPartNumber OCTET STRING,
|
|
eltPhdTransceiverInfoVendorRev OCTET STRING
|
|
}
|
|
|
|
eltPhdTransceiverInfoConnectorType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(0),
|
|
sc(1),
|
|
fibre-ch-st1(2),
|
|
fibre-ch-st2(3),
|
|
bnc-tnc(4),
|
|
fibre-ch-coaxial-headers(5),
|
|
fibrejack(6),
|
|
lc(7),
|
|
mt-rj(8),
|
|
mu(9),
|
|
sg(10),
|
|
optical-pigtail(11),
|
|
mpo-parallel-optic(12),
|
|
hssdc-ii(32),
|
|
copper-pigtail(33),
|
|
rj45(34),
|
|
no-separable-connector(35),
|
|
unallocated(127),
|
|
vendorspec(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connector type of the interface."
|
|
::= { eltPhdTransceiverInfoEntry 1 }
|
|
|
|
eltPhdTransceiverInfoType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(0),
|
|
gbic(1),
|
|
sff(2),
|
|
sfp-sfpplus(3),
|
|
xbi-300-pin(4),
|
|
xenpak(5),
|
|
xfp(6),
|
|
xff(7),
|
|
xfp-e(8),
|
|
xpak(9),
|
|
x2(10),
|
|
dwdm-sfp(11),
|
|
qsfp(12),
|
|
qsfpplus(13),
|
|
reserved(127),
|
|
vendorspec(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of the interface, such as SFP/XFP/GBIC."
|
|
::= { eltPhdTransceiverInfoEntry 2 }
|
|
|
|
eltPhdTransceiverInfoComplianceCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Compliance code read from the transceiver."
|
|
::= { eltPhdTransceiverInfoEntry 3 }
|
|
|
|
eltPhdTransceiverInfoWaveLength OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Wave length of the interface, measured in nanometer."
|
|
::= { eltPhdTransceiverInfoEntry 4 }
|
|
|
|
eltPhdTransceiverInfoVendorName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vendor name of the interface."
|
|
::= { eltPhdTransceiverInfoEntry 5 }
|
|
|
|
eltPhdTransceiverInfoSerialNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial number of the interface."
|
|
::= { eltPhdTransceiverInfoEntry 6 }
|
|
|
|
eltPhdTransceiverInfoFiberDiameterType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fiber9(1),
|
|
fiber50(2),
|
|
fiber625(3),
|
|
copper(4),
|
|
unknown(65535)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The diameter of the fiber, measured in micron.
|
|
fiber9 - 9 micron multi-mode fiber
|
|
fiber50 - 50 micron multi-mode fiber
|
|
fiber625 - 62.5 micron multi-mode fiber
|
|
copper - copper cable."
|
|
::= { eltPhdTransceiverInfoEntry 7 }
|
|
|
|
eltPhdTransceiverInfoTransferDistance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximal distance which the interface could transmit,
|
|
measured in meter."
|
|
::= { eltPhdTransceiverInfoEntry 8 }
|
|
|
|
eltPhdTransceiverInfoDiagnostic OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicating whether the digital diagnostic monitoring function is supported or not."
|
|
::= { eltPhdTransceiverInfoEntry 9 }
|
|
|
|
eltPhdTransceiverInfoPartNumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Part number provided by SFP vendor."
|
|
::= { eltPhdTransceiverInfoEntry 10 }
|
|
|
|
eltPhdTransceiverInfoVendorRev OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Revision level for part number provided by vendor."
|
|
::= { eltPhdTransceiverInfoEntry 11 }
|
|
|
|
--
|
|
-- eltPhdUnitGenParamTable
|
|
--
|
|
|
|
eltPhdUnitGenParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltPhdUnitGenParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For each module (board) there is an entry describing it in this
|
|
module"
|
|
::= { eltMesPhysicalDescription 2 }
|
|
|
|
eltPhdUnitGenParamEntry OBJECT-TYPE
|
|
SYNTAX EltPhdUnitGenParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments existing RADLAN table rlPhdUnitGenParamTable"
|
|
AUGMENTS { rlPhdUnitGenParamEntry }
|
|
::= { eltPhdUnitGenParamTable 1 }
|
|
|
|
EltPhdUnitGenParamEntry ::= SEQUENCE {
|
|
eltPhdUnitGenParamCommitHash DisplayString,
|
|
eltPhdUnitGenParamBuildTag DisplayString,
|
|
eltPhdUnitGenParamBuildNumber DisplayString
|
|
}
|
|
|
|
eltPhdUnitGenParamCommitHash OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Hash of current commit."
|
|
::= { eltPhdUnitGenParamEntry 1 }
|
|
|
|
eltPhdUnitGenParamBuildTag OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Build branch."
|
|
::= { eltPhdUnitGenParamEntry 2 }
|
|
|
|
eltPhdUnitGenParamBuildNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Build describe number."
|
|
::= { eltPhdUnitGenParamEntry 3 }
|
|
|
|
--
|
|
-- eltCascadeTable
|
|
--
|
|
|
|
eltCascadeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltCascadeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments existing RADLAN table rlCascadeTable."
|
|
::= { eltMesPhysicalDescription 3 }
|
|
|
|
eltCascadeEntry OBJECT-TYPE
|
|
SYNTAX EltCascadeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of this table specifies a cascaded link information in a unit"
|
|
AUGMENTS { rlCascadeEntry }
|
|
::= { eltCascadeTable 1 }
|
|
|
|
EltCascadeEntry ::= SEQUENCE {
|
|
eltCascadeLastChange TimeTicks,
|
|
eltCascadeOperStatus INTEGER,
|
|
eltCascadeDuplexOperMode INTEGER,
|
|
eltCascadeOperSpeedDuplexAutoNegotiation INTEGER,
|
|
eltCascadeOperMdix INTEGER,
|
|
eltCascadeTransceiverType INTEGER,
|
|
eltCascadeIfType INTEGER,
|
|
eltCascadeFecOperMode INTEGER
|
|
}
|
|
|
|
eltCascadeLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the cascade interface
|
|
entered its current operational state."
|
|
::= { eltCascadeEntry 1 }
|
|
|
|
eltCascadeOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the state of this interface."
|
|
::= { eltCascadeEntry 2 }
|
|
|
|
eltCascadeDuplexOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
half(1),
|
|
full(2),
|
|
hybrid(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether this interface operates in half
|
|
duplex or full duplex mode."
|
|
::= { eltCascadeEntry 3 }
|
|
|
|
eltCascadeOperSpeedDuplexAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
hybrid(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If enabled the speed and duplex are determined by the device through
|
|
the autonegotiation process."
|
|
::= { eltCascadeEntry 4 }
|
|
|
|
eltCascadeOperMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
cross(2),
|
|
auto(3),
|
|
unknown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"cross - The interface is in crossover mode.
|
|
normal - The interface is not in crossover mode.
|
|
unknown - Only for port that its operative status is not present
|
|
or down."
|
|
::= { eltCascadeEntry 5 }
|
|
|
|
eltCascadeTransceiverType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
regular(1),
|
|
fiberOptics(2),
|
|
comboRegular(3),
|
|
comboFiberOptics(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the transceiver type of this interface."
|
|
::= { eltCascadeEntry 6 }
|
|
|
|
eltCascadeIfType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eth10M(1),
|
|
eth100M(2),
|
|
eth1000M(3),
|
|
eth10G(4),
|
|
eth20G(5),
|
|
eth40G(6),
|
|
eth100G(7),
|
|
unknown(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable specifies the type of interface."
|
|
::= { eltCascadeEntry 7 }
|
|
|
|
eltCascadeFecOperMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
auto(1),
|
|
cl74(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the actual Forward Error Correction (FEC) mode
|
|
that currently in use on the port."
|
|
::= { eltCascadeEntry 8 }
|
|
|
|
--
|
|
-- eltPhdTransceiverThresholdTable
|
|
--
|
|
|
|
eltPhdTransceiverThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltPhdTransceiverThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the threshold information of transceiver."
|
|
::= { eltMesPhdTransceiver 2 }
|
|
|
|
eltPhdTransceiverThresholdEntry OBJECT-TYPE
|
|
SYNTAX EltPhdTransceiverThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entry of the eltPhdTransceiverThresholdTable."
|
|
INDEX { ifIndex, eltPhdTransceiverThresholdType }
|
|
::= { eltPhdTransceiverThresholdTable 1 }
|
|
|
|
EltPhdTransceiverThresholdEntry ::=
|
|
SEQUENCE {
|
|
eltPhdTransceiverThresholdType INTEGER,
|
|
eltPhdTransceiverThresholdAction INTEGER,
|
|
eltPhdTransceiverThresholdHighAlarm INTEGER,
|
|
eltPhdTransceiverThresholdHighWarning INTEGER,
|
|
eltPhdTransceiverThresholdLowWarning INTEGER,
|
|
eltPhdTransceiverThresholdLowAlarm INTEGER
|
|
}
|
|
|
|
eltPhdTransceiverThresholdType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
temperature(0),
|
|
supply(1),
|
|
txBias(2),
|
|
txOutput(3),
|
|
rxOpticalPower(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value indicating the threshold to configure.
|
|
temperature - degree (Celsius) -127-127, voltage - microVolt 0-6550000,
|
|
current - microAmper 0-131000, output power or input power - microWatt 0-6553"
|
|
::= { eltPhdTransceiverThresholdEntry 1 }
|
|
|
|
eltPhdTransceiverThresholdAction OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none(0),
|
|
log(1),
|
|
send-trap(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"What action to perform when value is bad."
|
|
::= { eltPhdTransceiverThresholdEntry 2 }
|
|
|
|
eltPhdTransceiverThresholdHighAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See eltPhdTransceiverThresholdType for details"
|
|
::= { eltPhdTransceiverThresholdEntry 3 }
|
|
|
|
eltPhdTransceiverThresholdHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See eltPhdTransceiverThresholdType for details"
|
|
::= { eltPhdTransceiverThresholdEntry 4 }
|
|
|
|
eltPhdTransceiverThresholdLowWarning OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See eltPhdTransceiverThresholdType for details"
|
|
::= { eltPhdTransceiverThresholdEntry 5 }
|
|
|
|
eltPhdTransceiverThresholdLowAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"See eltPhdTransceiverThresholdType for details"
|
|
::= { eltPhdTransceiverThresholdEntry 6 }
|
|
|
|
--
|
|
-- eltMesPhdNsf
|
|
--
|
|
|
|
eltMesPhdNsf OBJECT IDENTIFIER ::= { eltMesPhysicalDescription 4 }
|
|
|
|
eltPhdNsfEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable Non-Stop Forwarding during the stack master switchover."
|
|
DEFVAL { false }
|
|
::= { eltMesPhdNsf 1 }
|
|
|
|
eltPhdNsfTime OBJECT-TYPE
|
|
SYNTAX INTEGER (60..600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the time period in which protocols wait for the new master to complete initialization.
|
|
The port states set by the former master is preserved during this time."
|
|
DEFVAL {120}
|
|
::= { eltMesPhdNsf 2 }
|
|
|
|
--
|
|
-- eltCascadeAdminTable
|
|
--
|
|
|
|
eltCascadeAdminTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EltCascadeAdminEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments existing RADLAN table rlCascadeAdminTable."
|
|
::= { eltMesPhysicalDescription 6 }
|
|
|
|
eltCascadeAdminEntry OBJECT-TYPE
|
|
SYNTAX EltCascadeAdminEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry of this table specifies a cascaded information in a unit after reset"
|
|
AUGMENTS { rlCascadeAdminEntry }
|
|
::= { eltCascadeAdminTable 1 }
|
|
|
|
EltCascadeAdminEntry ::= SEQUENCE {
|
|
eltCascadeAdminFec INTEGER
|
|
}
|
|
|
|
eltCascadeAdminFec OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
auto(1),
|
|
cl74(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable controls the Forward Error Correction (FEC) mode on the port."
|
|
::= { eltCascadeAdminEntry 1 }
|
|
|
|
END
|