- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
4783 lines
132 KiB
Text
4783 lines
132 KiB
Text
-- *****************************************************************
|
|
-- MGNT2.TXT: MIB
|
|
--
|
|
--MIB Part Number:3MI01002CABA
|
|
--MIB Version:01
|
|
--
|
|
-- Copyright (c) 2017 by Ekinops
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
|
|
EKINOPS-MGNT2-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
ekinops,
|
|
EkiState,
|
|
EkiOnOff,
|
|
EkiProtocol,
|
|
EkiApiState,
|
|
EkiLoadGWSW,
|
|
EkiLoadState,
|
|
EkiLoadPermutMethod,
|
|
EkiSynchroMode,
|
|
EkiLoadPermutMode
|
|
FROM EKINOPS-MIB
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Unsigned32,
|
|
Integer32,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
RowStatus
|
|
FROM SNMPv2-TC;
|
|
|
|
mgnt2 MODULE-IDENTITY
|
|
LAST-UPDATED "201701100000Z"
|
|
ORGANIZATION "Ekinops"
|
|
CONTACT-INFO
|
|
"Ekinops
|
|
|
|
3, rue Blaise Pascal
|
|
F-22300 Lannion / FRANCE
|
|
|
|
Tel : +33 (0)2 96 05 00 30
|
|
Fax : +33 (0)2 96 48 62 39
|
|
|
|
E-mail: support@ekinops.net"
|
|
DESCRIPTION
|
|
"MIB for Ekinops 360 management."
|
|
REVISION "200511240000Z"
|
|
DESCRIPTION
|
|
"Initial version."
|
|
REVISION "200601240000Z"
|
|
DESCRIPTION
|
|
"Add the ekicraft package table."
|
|
REVISION "200603100000Z"
|
|
DESCRIPTION
|
|
"Change Rack full to Rack Not Full"
|
|
REVISION "200605100000Z"
|
|
DESCRIPTION
|
|
"Gateways are managed by a table"
|
|
REVISION "200605230000Z"
|
|
DESCRIPTION
|
|
"Replace PBU by PM"
|
|
REVISION "200609280000Z"
|
|
DESCRIPTION
|
|
"CRAFT/LINUX Inventory Insertion"
|
|
REVISION "200612130000Z"
|
|
DESCRIPTION
|
|
"Plug-in inventory table insertion"
|
|
REVISION "200702090000Z"
|
|
DESCRIPTION
|
|
"Add Backpanel ,Fan inventory and error counters"
|
|
REVISION "200704240000Z"
|
|
DESCRIPTION
|
|
"Add detailed traps"
|
|
REVISION "200706190000Z"
|
|
DESCRIPTION
|
|
"Add ABS3 objects"
|
|
REVISION "200708270000Z"
|
|
DESCRIPTION
|
|
"Add Groups number in board table for pm1008dc"
|
|
REVISION "200711270000Z"
|
|
DESCRIPTION
|
|
"Update Ekinops Address,Helps on objects,Add Dcc management"
|
|
REVISION "200805200000Z"
|
|
DESCRIPTION
|
|
"Add syslog and ntp servers ip addresses"
|
|
REVISION "200806180000Z"
|
|
DESCRIPTION
|
|
"Add Inactivity Time out"
|
|
REVISION "200808180000Z"
|
|
DESCRIPTION
|
|
"Add Cli access, create a textual convention for DCC access.Add Craft Access"
|
|
REVISION "200810070000Z"
|
|
DESCRIPTION
|
|
"Invert code on DCC mode"
|
|
REVISION "200811190000Z"
|
|
DESCRIPTION
|
|
"Insert Chassis Ethernet Split"
|
|
REVISION "200901050000Z"
|
|
DESCRIPTION
|
|
"Insert Chassis Global Conf"
|
|
REVISION "200912150000Z"
|
|
DESCRIPTION
|
|
"Correction on traps"
|
|
REVISION "201001040000Z"
|
|
DESCRIPTION
|
|
"Insert CRIT/URG/NURG/Acknowledge"
|
|
REVISION "201002160000Z"
|
|
DESCRIPTION
|
|
"Add CondType and NMS parameters"
|
|
REVISION "201007160000Z"
|
|
DESCRIPTION
|
|
"Add perf management for the NMS"
|
|
REVISION "201010270000Z"
|
|
DESCRIPTION
|
|
"Add new filters for traps"
|
|
|
|
REVISION "201103170000Z"
|
|
DESCRIPTION
|
|
"Add new filters for traps"
|
|
REVISION "201104070000Z"
|
|
DESCRIPTION
|
|
"New mode on new ehternet input"
|
|
REVISION "201104130000Z"
|
|
DESCRIPTION
|
|
"Polling Manager fail insertion"
|
|
REVISION "201105270000Z"
|
|
DESCRIPTION
|
|
"Rajout AlarmType sur Extraction Fan"
|
|
REVISION "201106080000Z"
|
|
DESCRIPTION
|
|
"Rajout Cold Reset"
|
|
REVISION "201106300000Z"
|
|
DESCRIPTION
|
|
"PerfCapStatus new type"
|
|
REVISION "201109120000Z"
|
|
DESCRIPTION
|
|
"New data for Atom"
|
|
REVISION "201202080000Z"
|
|
DESCRIPTION
|
|
"PM labelling removal"
|
|
REVISION "201203190000Z"
|
|
DESCRIPTION
|
|
"Add mgnt2SubFunctionLabel for 100G"
|
|
REVISION "201207160000Z"
|
|
DESCRIPTION
|
|
"Minor cosmetic updates"
|
|
REVISION "201305280000Z"
|
|
DESCRIPTION
|
|
"RSTP configuration object"
|
|
REVISION "201305300000Z"
|
|
DESCRIPTION
|
|
"Dust filter insertion, CPU Temp warning"
|
|
REVISION "201308290000Z"
|
|
DESCRIPTION
|
|
"LLDP configuration object"
|
|
REVISION "201309040000Z"
|
|
DESCRIPTION
|
|
"MGNT Shutdown adding"
|
|
REVISION "201309110000Z"
|
|
DESCRIPTION
|
|
"Log file mode insertion"
|
|
REVISION "201311060000Z"
|
|
DESCRIPTION
|
|
"RADIUS objects"
|
|
REVISION "201407300000Z"
|
|
DESCRIPTION
|
|
"Node Controller objects"
|
|
REVISION "201409010000Z"
|
|
DESCRIPTION
|
|
"Probcause,AlarmType - NMS completion"
|
|
REVISION "201502110000Z"
|
|
DESCRIPTION
|
|
"HTTP configuration"
|
|
REVISION "201504010000Z"
|
|
DESCRIPTION
|
|
"Add bindings for Node Controller"
|
|
REVISION "201504140000Z"
|
|
DESCRIPTION
|
|
"RSTP Thresholds"
|
|
REVISION "201504140000Z"
|
|
DESCRIPTION
|
|
"Users privilege"
|
|
REVISION "201510090000Z"
|
|
DESCRIPTION
|
|
"Add in mgnt2SlotStatus"
|
|
REVISION "201511050000Z"
|
|
DESCRIPTION
|
|
"Appropriate Limits on SYNTAX of some OBJECT-TYPE "
|
|
REVISION "201605270000Z"
|
|
DESCRIPTION
|
|
"Add objects for fail login attemps"
|
|
REVISION "201606150000Z"
|
|
DESCRIPTION
|
|
"Removable Fan modules handling"
|
|
REVISION "201610120000Z"
|
|
DESCRIPTION
|
|
"Modification of numbering of the fans"
|
|
REVISION "201701100000Z"
|
|
DESCRIPTION
|
|
"FTP, TFTP enable disable"
|
|
::= { ekinops 7 }
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- TEXTUAL-CONVENTION
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
Mgnt2CliAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different type of access by ethernet for the CLI"
|
|
SYNTAX INTEGER {
|
|
noCliByEthernet(0),
|
|
cliBySSH(1),
|
|
cliByTelnet(2)
|
|
}
|
|
|
|
Mgnt2CraftAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "enables access to the CRAFT"
|
|
SYNTAX INTEGER {
|
|
noCraftAccess(0),
|
|
craftEnable(1),
|
|
craftEnableHttps(2)
|
|
}
|
|
|
|
Mgnt2DccAccessValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Dcc access"
|
|
SYNTAX INTEGER {
|
|
mode1Slots2s4s6s8s10(0),
|
|
mode2Slots2s6s10s14s18(1)
|
|
}
|
|
|
|
Mgnt2TrapModeValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the trap generation"
|
|
SYNTAX INTEGER {
|
|
syntheticTrap(0),
|
|
detailedTrap(1),
|
|
nmsTrap(2)
|
|
}
|
|
|
|
Mgnt2AckMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes to acknowledge alarms"
|
|
SYNTAX INTEGER {
|
|
modeA(1),
|
|
modeB(2)
|
|
}
|
|
|
|
Mgnt2PerfResyncValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the trap generation"
|
|
SYNTAX INTEGER {
|
|
perfResyncIdle(1),
|
|
perfResyncSync(2),
|
|
perfResyncReady(3),
|
|
perfResyncDelete(4)
|
|
}
|
|
|
|
Mgnt2NetMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the network management"
|
|
SYNTAX INTEGER {
|
|
switch(1),
|
|
gateway(2)
|
|
}
|
|
|
|
Mgnt2MasterEthMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Master"
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
|
|
Mgnt2SubnetEthMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the Subnet"
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dhcp(2)
|
|
}
|
|
|
|
Mgnt2AuthTypeValues ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Various types of authentication processes"
|
|
SYNTAX INTEGER {
|
|
authLocal(0),
|
|
authRADIUS(1),
|
|
authLDAP(2)
|
|
}
|
|
|
|
Mgnt2LogFileMode ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "different modes for the log files"
|
|
SYNTAX INTEGER {
|
|
disabled (0),
|
|
linear(1),
|
|
rotary(2)
|
|
}
|
|
|
|
|
|
Mgnt2SlotStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Status of the slot"
|
|
SYNTAX INTEGER {
|
|
slotEmpty(0),
|
|
pmReady(1),
|
|
pmReset(2),
|
|
pmLoad(3),
|
|
pmPassive(4),
|
|
pmUnknown(5),
|
|
pmNotReady(6)
|
|
}
|
|
|
|
|
|
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 MIB root mapping
|
|
--
|
|
-- *****************************************************************
|
|
mgnt2SNMPAgentData OBJECT IDENTIFIER ::= { mgnt2 1 }
|
|
mgnt2Hardware OBJECT IDENTIFIER ::= { mgnt2 2}
|
|
mgnt2Traps OBJECT IDENTIFIER ::= { mgnt2 3}
|
|
mgnt2SoftwareManagement OBJECT IDENTIFIER ::= { mgnt2 4}
|
|
mgnt2ConfigManagement OBJECT IDENTIFIER ::= { mgnt2 5}
|
|
mgnt2RemoteInventory OBJECT IDENTIFIER ::= { mgnt2 6}
|
|
mgnt2ErrorCounters OBJECT IDENTIFIER ::= { mgnt2 7}
|
|
mgnt2Perf OBJECT IDENTIFIER ::= { mgnt2 8}
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 SNMP Agent informations
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2IPmanagment OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 1 }
|
|
|
|
|
|
mgnt2GigmManagerIpAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmManagerIpAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager IP address Table."
|
|
::= { mgnt2IPmanagment 1 }
|
|
|
|
mgnt2GigmManagerIpAddressEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmManagerIpAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { mgnt2GigmManagerIpIndex }
|
|
::= { mgnt2GigmManagerIpAddressTable 1 }
|
|
|
|
Mgnt2GigmManagerIpAddressEntry ::= SEQUENCE {
|
|
mgnt2GigmManagerIpIndex Integer32,
|
|
mgnt2GigmManagerIpAddress IpAddress,
|
|
mgnt2GigmManagerIpAddressTableRowStatus RowStatus,
|
|
mgnt2GigmManagerTrapPort Integer32,
|
|
mgnt2GigmManagerEnableCtrl EkiOnOff,
|
|
mgnt2GigmManagerEnableConfig EkiOnOff,
|
|
mgnt2GigmManagerEnableEvent EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmCrit EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmMajor EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmMinor EkiOnOff,
|
|
mgnt2GigmManagerRegistrationTimeout Integer32,
|
|
mgnt2GigmManagerEnableAlarmWarning EkiOnOff,
|
|
mgnt2GigmManagerEnableAlarmIndeterminate EkiOnOff
|
|
}
|
|
|
|
mgnt2GigmManagerIpIndex OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the IP address of the manager"
|
|
::= { mgnt2GigmManagerIpAddressEntry 1 }
|
|
|
|
mgnt2GigmManagerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the manager:This OID defines the IP
|
|
address of the SNMP Manager attached to the Mgnt2"
|
|
::= { mgnt2GigmManagerIpAddressEntry 2 }
|
|
|
|
mgnt2GigmManagerIpAddressTableRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this row."
|
|
::= { mgnt2GigmManagerIpAddressEntry 3 }
|
|
|
|
mgnt2GigmManagerTrapPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager UDP port."
|
|
::= { mgnt2GigmManagerIpAddressEntry 4 }
|
|
|
|
mgnt2GigmManagerEnableCtrl OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of Ctrl."
|
|
::= { mgnt2GigmManagerIpAddressEntry 5 }
|
|
|
|
mgnt2GigmManagerEnableConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of config."
|
|
::= { mgnt2GigmManagerIpAddressEntry 6 }
|
|
|
|
mgnt2GigmManagerEnableEvent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of event."
|
|
::= { mgnt2GigmManagerIpAddressEntry 7 }
|
|
|
|
mgnt2GigmManagerEnableAlarmCrit OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of crit alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 8 }
|
|
|
|
mgnt2GigmManagerEnableAlarmMajor OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of major alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 9 }
|
|
|
|
mgnt2GigmManagerEnableAlarmMinor OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of minor alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 10 }
|
|
|
|
|
|
mgnt2GigmManagerRegistrationTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time-out for manager activities."
|
|
::= { mgnt2GigmManagerIpAddressEntry 11 }
|
|
|
|
mgnt2GigmManagerEnableAlarmWarning OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of warning alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 12 }
|
|
|
|
mgnt2GigmManagerEnableAlarmIndeterminate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabling trap of indeterminate alarm."
|
|
::= { mgnt2GigmManagerIpAddressEntry 13 }
|
|
|
|
|
|
mgnt2GigmBoardIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the Chassis:This OID defines the IP
|
|
address of the Mgnt2"
|
|
::= { mgnt2IPmanagment 2 }
|
|
|
|
mgnt2GigmIPAddresByDHCP OBJECT-TYPE
|
|
SYNTAX EkiState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address retrieved by DHCP:If enabled, the IP
|
|
address is retrieved by DHCP, in which case changes
|
|
take effect after a board reset. If disabled the
|
|
object, mgnt2GigmBoardIpAddress defines the address"
|
|
::= { mgnt2IPmanagment 3 }
|
|
|
|
|
|
mgnt2GigmNetmask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Netmask for the board IP address:This OID defined
|
|
the IP Subnet mask of the Mgnt2"
|
|
::= { mgnt2IPmanagment 4 }
|
|
|
|
mgnt2GigmGatewayAddressTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmGatewayAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway IP address Table: This table contains all
|
|
the gateway IP addresses."
|
|
::= { mgnt2IPmanagment 5 }
|
|
|
|
mgnt2GigmGatewayAddressEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmGatewayAddressEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
INDEX { mgnt2GigmGatewayIndex }
|
|
::= { mgnt2GigmGatewayAddressTable 1 }
|
|
|
|
Mgnt2GigmGatewayAddressEntry ::= SEQUENCE {
|
|
mgnt2GigmGatewayIndex Integer32,
|
|
mgnt2GigmGatewayAddress IpAddress,
|
|
mgnt2GigmGatewayOrder Integer32
|
|
}
|
|
|
|
mgnt2GigmGatewayIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..1)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the IP address of the gateway"
|
|
::= { mgnt2GigmGatewayAddressEntry 1 }
|
|
|
|
mgnt2GigmGatewayAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the gateway :This OID defines the IP
|
|
address of the gateway attached to the Chassis"
|
|
::= { mgnt2GigmGatewayAddressEntry 2 }
|
|
|
|
mgnt2GigmGatewayOrder OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway priority: This OID defines the priority of
|
|
the gateway (lower number for higher priority)"
|
|
::= { mgnt2GigmGatewayAddressEntry 3 }
|
|
|
|
mgnt2GigmSyslog OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the syslog server:This OID defines
|
|
the IP address of the syslog of the Mgnt2"
|
|
::= { mgnt2IPmanagment 6 }
|
|
|
|
mgnt2GigmNtpServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the ntp server:This OID defines
|
|
the IP address of the ntp server for the Mgnt2"
|
|
::= { mgnt2IPmanagment 7 }
|
|
|
|
|
|
mgnt2GigmNodeIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node IP address :This OID defines
|
|
the Node IP address in node controller mode for the Mgnt2"
|
|
::= { mgnt2IPmanagment 8 }
|
|
|
|
|
|
mgnt2ModulesManagement OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 2 }
|
|
|
|
mgnt2GigmBoardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of PMs plugged in the Chassis"
|
|
::= { mgnt2ModulesManagement 1 }
|
|
|
|
mgnt2GigmBoardEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmBoardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the PMs table"
|
|
INDEX { mgnt2IndexBoards }
|
|
::= { mgnt2GigmBoardTable 1 }
|
|
|
|
|
|
|
|
Mgnt2GigmBoardEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexBoards
|
|
Integer32,
|
|
mgnt2Position
|
|
Integer32,
|
|
mgnt2Name
|
|
DisplayString,
|
|
mgnt2PortNumber
|
|
Integer32,
|
|
mgnt2LineNumber
|
|
Integer32,
|
|
mgnt2GroupNumber
|
|
Integer32,
|
|
mgnt2RootOIDInventory
|
|
OBJECT IDENTIFIER,
|
|
mgnt2SlotOcc
|
|
DisplayString,
|
|
mgnt2SubFunctionLabel
|
|
DisplayString,
|
|
mgnt2SlotStatus
|
|
Mgnt2SlotStatus
|
|
}
|
|
|
|
|
|
mgnt2IndexBoards OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for PMs table"
|
|
::= { mgnt2GigmBoardEntry 1 }
|
|
|
|
mgnt2Position OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number:This OID gives the slot number in
|
|
which the PM is plugged"
|
|
::= { mgnt2GigmBoardEntry 2 }
|
|
|
|
mgnt2Name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM name:This OID gives the name of the PM plugged
|
|
in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 3 }
|
|
|
|
mgnt2PortNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Client Ports:This OID gives the number of
|
|
client ports on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 4 }
|
|
|
|
mgnt2LineNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Line Ports:This OID gives the number of line
|
|
ports on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 5 }
|
|
|
|
mgnt2GroupNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Groups:This OID gives the number of group
|
|
of clients on the PM plugged in the Mgnt2"
|
|
::= { mgnt2GigmBoardEntry 6 }
|
|
|
|
mgnt2RootOIDInventory OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"root oid of the inventory leaf of the corresponding PM"
|
|
::= { mgnt2GigmBoardEntry 7 }
|
|
|
|
mgnt2SlotOcc OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot occupied:This OID gives the slots taken
|
|
by this PM"
|
|
::= { mgnt2GigmBoardEntry 8 }
|
|
|
|
|
|
mgnt2SubFunctionLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub Function Label: This OID gives the name of the sub
|
|
function embedded on the Chassis. (applied only on the
|
|
100G Chassis)"
|
|
::= { mgnt2GigmBoardEntry 9 }
|
|
|
|
|
|
|
|
mgnt2SlotStatus OBJECT-TYPE
|
|
SYNTAX Mgnt2SlotStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot Status: This OID gives the status of the slot
|
|
in the Chassis: See Textual COnvention"
|
|
::= { mgnt2GigmBoardEntry 10 }
|
|
|
|
|
|
|
|
mgnt2GigmSelectedBoard OBJECT-TYPE
|
|
SYNTAX INTEGER(1..256)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number selected:PM selected for further
|
|
operations in the Ekinops module board tree. This
|
|
number is the slot number."
|
|
::= { mgnt2ModulesManagement 7 }
|
|
|
|
|
|
|
|
|
|
mgnt2GigmMibsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmMibsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"List of MIBs supported by the Chassis SNMPAgent"
|
|
::= { mgnt2SNMPAgentData 4 }
|
|
|
|
mgnt2GigmMibsEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmMibsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Row definition for MIBs table"
|
|
INDEX { mgnt2IndexMibs }
|
|
::= { mgnt2GigmMibsTable 1 }
|
|
|
|
|
|
|
|
Mgnt2GigmMibsEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexMibs
|
|
Integer32,
|
|
mgnt2MibName
|
|
DisplayString,
|
|
mgnt2MibPartNumber
|
|
DisplayString
|
|
}
|
|
|
|
|
|
mgnt2IndexMibs OBJECT-TYPE
|
|
SYNTAX Integer32(1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Index for MIBs table"
|
|
::= { mgnt2GigmMibsEntry 1 }
|
|
|
|
mgnt2MibName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MIB name:This OID gives the name of the MIBs
|
|
supported by the SNMP Agent"
|
|
::= { mgnt2GigmMibsEntry 2 }
|
|
|
|
mgnt2MibPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MIB Part Number:This OID gives the part number of the MIBs
|
|
supported by the SNMP Agent"
|
|
::= { mgnt2GigmMibsEntry 3 }
|
|
|
|
mgnt2GigmLogicalName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mgnt2 name:This OID defines the name of the Mgnt2"
|
|
::= { mgnt2SNMPAgentData 5 }
|
|
|
|
mgnt2GigmEqptType OBJECT-TYPE
|
|
SYNTAX Integer32(1..128)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equipment type:This OID defines the type of the Equipment"
|
|
::= { mgnt2SNMPAgentData 6 }
|
|
|
|
mgnt2GigmTrapCount OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 7 }
|
|
|
|
mgnt2GigmTrapCounter OBJECT-TYPE
|
|
SYNTAX Integer32(1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap counter:This OID counts the number of trap sent"
|
|
::= { mgnt2GigmTrapCount 1 }
|
|
|
|
mgnt2GigmResetTrapCounter OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset trap counter:This OID reset the trap counter to 0"
|
|
::= { mgnt2GigmTrapCount 2 }
|
|
|
|
|
|
mgnt2GigmSecurity OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 8 }
|
|
|
|
mgnt2GigmRoCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Get community:This OID defines the community for the
|
|
SNMP Get function"
|
|
::= { mgnt2GigmSecurity 1 }
|
|
|
|
mgnt2GigmRwCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Set community:This OID defines the community for the
|
|
SNMP Set function"
|
|
::= { mgnt2GigmSecurity 2 }
|
|
|
|
|
|
mgnt2GigmTrapCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP Trap community:This OID defines the community for the
|
|
SNMP Trap function"
|
|
::= { mgnt2GigmSecurity 3 }
|
|
|
|
|
|
mgnt2GigmTime OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 9 }
|
|
|
|
mgnt2GigmCurrentHour OBJECT-TYPE
|
|
SYNTAX INTEGER(0..23)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Hour time:This OID defines the hour of the chassis' time"
|
|
::= { mgnt2GigmTime 1 }
|
|
|
|
mgnt2GigmCurrentMinute OBJECT-TYPE
|
|
SYNTAX INTEGER(0..59)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Minute time:This OID defines the minute of the chassis' time"
|
|
::= { mgnt2GigmTime 2 }
|
|
|
|
mgnt2GigmCurrentYear OBJECT-TYPE
|
|
SYNTAX INTEGER(1970..3000)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis year date:This OID defines the year of the chassis' date"
|
|
::= { mgnt2GigmTime 3 }
|
|
|
|
mgnt2GigmCurrentMonth OBJECT-TYPE
|
|
SYNTAX INTEGER(1..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis month date:This OID defines the month of the chassis' date"
|
|
::= { mgnt2GigmTime 4 }
|
|
|
|
mgnt2GigmCurrentDay OBJECT-TYPE
|
|
SYNTAX INTEGER(1..31)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis day date:This OID defines the day of the chassis' date"
|
|
::= { mgnt2GigmTime 5 }
|
|
|
|
|
|
|
|
mgnt2Authentication OBJECT IDENTIFIER ::= { mgnt2SNMPAgentData 10 }
|
|
|
|
mgnt2GigmRadiusServer OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of the RADIUS server:This OID defines
|
|
the IP address of the external RADIUS server for authentication"
|
|
::= { mgnt2Authentication 1 }
|
|
|
|
mgnt2GigmRadiusPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCP port number of the RADIUS server:This OID defines
|
|
the TCP port number of the external RADIUS server for
|
|
authentication"
|
|
::= { mgnt2Authentication 2 }
|
|
|
|
mgnt2GigmRadiusSecret OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shared secret of the RADIUS server:This OID defines
|
|
the shared secret password of the RADIUS server for
|
|
authentication"
|
|
::= { mgnt2Authentication 3 }
|
|
|
|
|
|
mgnt2GigmLdapHost OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"IP address of the LDAP host:This OID defines
|
|
the IP address of the external LDAP server for authentication"
|
|
::= { mgnt2Authentication 4 }
|
|
|
|
mgnt2GigmLdapPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"TCP port number of the LDAP server:This OID defines
|
|
the TCP port number of the external LDAP server for
|
|
authentication"
|
|
::= { mgnt2Authentication 5 }
|
|
|
|
|
|
mgnt2GigmLdapBase OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"LDAP base:This OID defines the name of the search
|
|
base of the LDAP server for
|
|
authentication<Help>LDAP base name spelled as follows:
|
|
'ou=users,ou=network,dc=yourcompany,dc=net'"
|
|
::= { mgnt2Authentication 6 }
|
|
|
|
mgnt2GigmLdapVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Protocol number in use by the LDAP server:This OID defines
|
|
the protocol version used by the external LDAP server for
|
|
authentication<Help>Protocol version used by the external LDAP
|
|
server for authentication"
|
|
::= { mgnt2Authentication 7 }
|
|
|
|
mgnt2GigmLdapBindDn OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"LDAP Bind DN:This OID defines the login name used to connect
|
|
into the LDAP server base for
|
|
authentication<Help>LDAP binddn spelled as follows:
|
|
'cn=ldap_admin,dc=yourcompany,dc=net'"
|
|
::= { mgnt2Authentication 8 }
|
|
|
|
mgnt2GigmLdapBindPw OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Credentials to bind the LDAP server with:This OID defines
|
|
the credentials to bind the LDAP server with for
|
|
authentication<Help>Credentials for LDAP access (bindpw)"
|
|
::= { mgnt2Authentication 9 }
|
|
|
|
|
|
mgnt2GigmLdapScope OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Scope for LDAP base search:This OID defines
|
|
the search scope for an LDAP base search
|
|
<Help>LDAP search scope"
|
|
::= { mgnt2Authentication 10 }
|
|
|
|
mgnt2GigmLdapPamPasswd OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PAM password handling:This OID defines
|
|
the way the PAM password is handled for LDAP authentication
|
|
<Help>The 'pam_password' option sould be one of the following:
|
|
'clear', 'crypt', 'md5', 'racf', 'exop'"
|
|
::= { mgnt2Authentication 11 }
|
|
|
|
mgnt2GigmAuthenticationType OBJECT-TYPE
|
|
SYNTAX Mgnt2AuthTypeValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Authentication type in use"
|
|
::= { mgnt2Authentication 12 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Software Management tables
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2DwlUploadingTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlUploadingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"SNMP Agent SW packages in ram: List of the SNMP
|
|
agent software packages available in /ram for
|
|
download on the Chassis managment module flash"
|
|
::= { mgnt2SoftwareManagement 1 }
|
|
|
|
mgnt2DwlUploadingEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlUploadingEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2IndexUpload }
|
|
::= { mgnt2DwlUploadingTable 1 }
|
|
|
|
Mgnt2DwlUploadingEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexUpload
|
|
Integer32,
|
|
mgnt2DwlUploadFileName
|
|
DisplayString,
|
|
mgnt2ImmediateReplacement
|
|
EkiState,
|
|
mgnt2FileUpload
|
|
EkiOnOff,
|
|
mgnt2DeletePackageFromRam
|
|
EkiOnOff,
|
|
mgnt2FlashingInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexUpload OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for uploading table"
|
|
::= { mgnt2DwlUploadingEntry 1 }
|
|
|
|
mgnt2DwlUploadFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package filename in RAM:This OID gives the name of
|
|
the SNMP agent software packages in RAM"
|
|
::= { mgnt2DwlUploadingEntry 2 }
|
|
|
|
mgnt2ImmediateReplacement OBJECT-TYPE
|
|
SYNTAX EkiState
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediat Agent Replacement:This OID indicates to
|
|
switch to selected SNMP agent immediately or after
|
|
reset of the MGNT2"
|
|
::= { mgnt2DwlUploadingEntry 3 }
|
|
|
|
mgnt2FileUpload OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Agent File Upload:This OID validates the upload of
|
|
the SNMP agent from RAM to FLASH"
|
|
::= { mgnt2DwlUploadingEntry 4 }
|
|
|
|
mgnt2DeletePackageFromRam OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete Package from RAM:This OID requests to delete
|
|
the SNMP Agent SW package from RAM"
|
|
::= { mgnt2DwlUploadingEntry 5 }
|
|
|
|
mgnt2FlashingInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Flashing in Progress:This OID indicates whether there
|
|
is a file upload to FLASH in progress"
|
|
::= { mgnt2DwlUploadingEntry 6 }
|
|
|
|
|
|
|
|
mgnt2DwlPackageTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlPackageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of SNMP agent software packages
|
|
present in flash memory"
|
|
::= { mgnt2SoftwareManagement 2 }
|
|
|
|
mgnt2DwlPackageEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlPackageEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package management table"
|
|
INDEX { mgnt2IndexPackage }
|
|
::= { mgnt2DwlPackageTable 1 }
|
|
|
|
Mgnt2DwlPackageEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexPackage
|
|
Integer32,
|
|
mgnt2DwlPackageFileName
|
|
DisplayString,
|
|
mgnt2ExtractedPack
|
|
EkiOnOff,
|
|
mgnt2SwitchTo
|
|
EkiOnOff,
|
|
mgnt2Immediate
|
|
EkiOnOff,
|
|
mgnt2DeletePackageFromFlash
|
|
EkiOnOff,
|
|
mgnt2PackageExtractionInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexPackage OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for package management table"
|
|
::= { mgnt2DwlPackageEntry 1 }
|
|
|
|
mgnt2DwlPackageFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package File name in FLASH:This OID gives the name
|
|
of the SNMP agent software package in FLASH"
|
|
::= { mgnt2DwlPackageEntry 2 }
|
|
|
|
mgnt2ExtractedPack OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Extracted SNMP agent software pack.: Indicates
|
|
whether the package is currently extracted in the FLASH.
|
|
If it is, it must not be deleted"
|
|
::= { mgnt2DwlPackageEntry 3 }
|
|
|
|
mgnt2SwitchTo OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Switch to package:This OID activates the SNMP Agent
|
|
Software package"
|
|
::= { mgnt2DwlPackageEntry 4 }
|
|
|
|
mgnt2Immediate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediate SNMP agent activation: This OID indicates
|
|
whether the package is scheduled for immediate
|
|
activation or activation will take place following the
|
|
next reset"
|
|
::= { mgnt2DwlPackageEntry 5 }
|
|
|
|
mgnt2DeletePackageFromFlash OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete package from FLASH:This OID deletes the SNMP
|
|
agent software package from the FLASH"
|
|
::= { mgnt2DwlPackageEntry 6 }
|
|
|
|
mgnt2PackageExtractionInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package extraction in progress:This OID indicates that
|
|
a SNMP agent software activation is in progress"
|
|
::= { mgnt2DwlPackageEntry 7 }
|
|
|
|
mgnt2DwlUploadingTableUpdate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Uploading Table update:This OID updates the contents of
|
|
the uploading table"
|
|
::= { mgnt2SoftwareManagement 3 }
|
|
|
|
|
|
|
|
|
|
mgnt2LoadPMTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2LoadPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of the PM module software files (GW/SW)
|
|
present on the repository"
|
|
::= { mgnt2SoftwareManagement 4 }
|
|
|
|
|
|
mgnt2LoadPMEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2LoadPMEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the LOAD article table"
|
|
INDEX { mgnt2LoadPMIndex }
|
|
::= { mgnt2LoadPMTable 1 }
|
|
|
|
Mgnt2LoadPMEntry::=
|
|
SEQUENCE {
|
|
mgnt2LoadPMIndex
|
|
Integer32,
|
|
mgnt2LoadFileName
|
|
DisplayString,
|
|
mgnt2LoadFileType
|
|
EkiLoadGWSW,
|
|
mgnt2LoadState
|
|
EkiLoadState,
|
|
mgnt2LoadModuleNumber
|
|
Integer32,
|
|
mgnt2LoadResetMethod
|
|
EkiLoadPermutMethod,
|
|
mgnt2LoadResetMode
|
|
EkiLoadPermutMode,
|
|
mgnt2LoadBankNumber
|
|
Integer32,
|
|
mgnt2LoadDownloadProgress
|
|
Integer32,
|
|
mgnt2LoadTransfer
|
|
EkiOnOff,
|
|
mgnt2LoadDelete
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2LoadPMIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..32)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for Load article table"
|
|
::= { mgnt2LoadPMEntry 1 }
|
|
|
|
mgnt2LoadFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM Upgrade filename:This OID gives the name of
|
|
the file"
|
|
::= { mgnt2LoadPMEntry 2 }
|
|
|
|
mgnt2LoadFileType OBJECT-TYPE
|
|
SYNTAX EkiLoadGWSW
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade file type:This OID gives the type of
|
|
file (gateware or software)"
|
|
::= { mgnt2LoadPMEntry 3 }
|
|
|
|
mgnt2LoadState OBJECT-TYPE
|
|
SYNTAX EkiLoadState
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade status:This OID gives the status of the
|
|
selected Load file"
|
|
::= { mgnt2LoadPMEntry 4 }
|
|
|
|
mgnt2LoadModuleNumber OBJECT-TYPE
|
|
SYNTAX Integer32(1..8)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM ugprade target:This OID defines the slot number
|
|
of the PM to upgrade"
|
|
::= { mgnt2LoadPMEntry 5 }
|
|
|
|
mgnt2LoadResetMethod OBJECT-TYPE
|
|
SYNTAX EkiLoadPermutMethod
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade reset method:This OID defines the reset
|
|
method (manual, immediate or scheduled)"
|
|
::= { mgnt2LoadPMEntry 6 }
|
|
|
|
mgnt2LoadResetMode OBJECT-TYPE
|
|
SYNTAX EkiLoadPermutMode
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade reset mode:This OID defines the type of
|
|
reset (cold or warm)"
|
|
::= { mgnt2LoadPMEntry 7 }
|
|
|
|
mgnt2LoadBankNumber OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade bank number:This OID defines the target
|
|
bank number in the PM's flash"
|
|
::= { mgnt2LoadPMEntry 8 }
|
|
|
|
mgnt2LoadDownloadProgress OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade progress:This OID gives the upgrade
|
|
progress (percentage)"
|
|
::= { mgnt2LoadPMEntry 9 }
|
|
|
|
mgnt2LoadTransfer OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade transfer:This OID launchs the transfer
|
|
of the associated file to the selected PM's flash"
|
|
::= { mgnt2LoadPMEntry 10 }
|
|
|
|
mgnt2LoadDelete OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"PM upgrade delete file:This OID deletes the
|
|
associated file from the RAM of the management board"
|
|
::= { mgnt2LoadPMEntry 11 }
|
|
|
|
|
|
mgnt2LoadPMTableUpdate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Load PM Table update:This OID updates the contents
|
|
of the Load table"
|
|
::= { mgnt2SoftwareManagement 5 }
|
|
|
|
|
|
|
|
mgnt2DwlEkicraftPkgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2DwlEkicraftPkgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of Ekicraft software packages
|
|
present in flash memory"
|
|
::= { mgnt2SoftwareManagement 6 }
|
|
|
|
mgnt2DwlEkicraftPkgEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2DwlEkicraftPkgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package management table"
|
|
INDEX { mgnt2IndexEkicraftPkg }
|
|
::= { mgnt2DwlEkicraftPkgTable 1 }
|
|
|
|
Mgnt2DwlEkicraftPkgEntry::=
|
|
SEQUENCE {
|
|
mgnt2IndexEkicraftPkg
|
|
Integer32,
|
|
mgnt2DwlEkicraftPkgFileName
|
|
DisplayString,
|
|
mgnt2DwlEkicraftExtractedPack
|
|
EkiOnOff,
|
|
mgnt2DwlEkicraftSwitchTo
|
|
EkiOnOff,
|
|
mgnt2DwlEkicraftImmediate
|
|
EkiOnOff,
|
|
mgnt2DeleteEkicraftPkgFromFlash
|
|
EkiOnOff,
|
|
mgnt2EkicraftPkgExtractionInProgress
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2IndexEkicraftPkg OBJECT-TYPE
|
|
SYNTAX Integer32(0..4)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index for Ekicraft package management table"
|
|
::= { mgnt2DwlEkicraftPkgEntry 1 }
|
|
|
|
mgnt2DwlEkicraftPkgFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package File name in FLASH:This OID gives the name
|
|
of the Ekicraft software package in FLASH"
|
|
::= { mgnt2DwlEkicraftPkgEntry 2 }
|
|
|
|
mgnt2DwlEkicraftExtractedPack OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Extracted Ekicraft software pack.: Indicates
|
|
whether the package is currently extracted in the FLASH.
|
|
If it is, it must not be deleted"
|
|
::= { mgnt2DwlEkicraftPkgEntry 3 }
|
|
|
|
mgnt2DwlEkicraftSwitchTo OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Switch to package:This OID activates the Ekicraft
|
|
Software package"
|
|
::= { mgnt2DwlEkicraftPkgEntry 4 }
|
|
|
|
mgnt2DwlEkicraftImmediate OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Immediate Ekicraft activation: This OID indicates
|
|
whether the package is scheduled for immediate
|
|
activation or activation will take place following the
|
|
next reset"
|
|
::= { mgnt2DwlEkicraftPkgEntry 5 }
|
|
|
|
mgnt2DeleteEkicraftPkgFromFlash OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Delete package from FLASH:This OID deletes the Ekicraft
|
|
software package from the FLASH"
|
|
::= { mgnt2DwlEkicraftPkgEntry 6 }
|
|
|
|
mgnt2EkicraftPkgExtractionInProgress OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Package extraction in progress:This OID indicates that
|
|
an Ekicraft activation is in progress"
|
|
::= { mgnt2DwlEkicraftPkgEntry 7 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- Config management tables
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2CnfUploadConfigFilesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2CnfUploadConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of configuration files uploaded to RAM"
|
|
::= { mgnt2ConfigManagement 1 }
|
|
|
|
mgnt2CnfUploadConfigFilesEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2CnfUploadConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2CnfUploadConfigIndex }
|
|
::= { mgnt2CnfUploadConfigFilesTable 1 }
|
|
|
|
Mgnt2CnfUploadConfigFilesEntry::=
|
|
SEQUENCE {
|
|
mgnt2CnfUploadConfigIndex
|
|
Integer32,
|
|
mgnt2CnfConfigFileName
|
|
DisplayString,
|
|
mgnt2CnfConfigSlot
|
|
Integer32,
|
|
mgnt2CnfConfigUpload
|
|
EkiOnOff,
|
|
mgnt2CnfDeleteConfigFile
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2CnfUploadConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..16)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index of config files"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 1 }
|
|
|
|
mgnt2CnfConfigFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration filename in RAM:This OID gives the
|
|
name of the configuration file in RAM"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 2 }
|
|
|
|
mgnt2CnfConfigSlot OBJECT-TYPE
|
|
SYNTAX Integer32(0..3)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration target:This OID defines the target
|
|
slot number for the configuration file"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 3 }
|
|
|
|
mgnt2CnfConfigUpload OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Upload:This OID uploads the
|
|
configuration file to the specified slot number
|
|
in the PM FLASH"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 4 }
|
|
|
|
mgnt2CnfDeleteConfigFile OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration delete from RAM:This OID deletes the
|
|
configuration file from RAM"
|
|
::= { mgnt2CnfUploadConfigFilesEntry 5 }
|
|
|
|
|
|
|
|
|
|
mgnt2CnfManageConfigFilesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2CnfManageConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"List of configuration files uploaded to RAM"
|
|
::= { mgnt2ConfigManagement 2 }
|
|
|
|
mgnt2CnfManageConfigFilesEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2CnfManageConfigFilesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Row definition for the package uploading table"
|
|
INDEX { mgnt2CnfManageConfigIndex }
|
|
::= { mgnt2CnfManageConfigFilesTable 1 }
|
|
|
|
Mgnt2CnfManageConfigFilesEntry::=
|
|
SEQUENCE {
|
|
mgnt2CnfManageConfigIndex
|
|
Integer32,
|
|
mgnt2CnfManageConfigFileID
|
|
DisplayString,
|
|
mgnt2CnfManageConfigFileName
|
|
DisplayString,
|
|
mgnt2CnfModuleSlotNumber
|
|
Integer32,
|
|
mgnt2CnfBackupConfig
|
|
EkiOnOff,
|
|
mgnt2CnfRestoreConfig
|
|
EkiOnOff,
|
|
mgnt2CnfExportConfig
|
|
EkiOnOff,
|
|
mgnt2CnfDeleteConfig
|
|
EkiOnOff
|
|
}
|
|
|
|
mgnt2CnfManageConfigIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..16)
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Index of config file slots"
|
|
::= { mgnt2CnfManageConfigFilesEntry 1 }
|
|
|
|
mgnt2CnfManageConfigFileID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration file ID in FLASH:This OID gives the
|
|
ID of the configuration file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 2 }
|
|
|
|
mgnt2CnfManageConfigFileName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration file name in FLASH:This OID gives the
|
|
name of the configuration file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 3 }
|
|
|
|
mgnt2CnfModuleSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32(3..6)
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration target:This OID defines the target
|
|
module slot number for the configuration file"
|
|
::= { mgnt2CnfManageConfigFilesEntry 4 }
|
|
|
|
mgnt2CnfBackupConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration backup:This OID backups the
|
|
configuration of the specified module to the
|
|
selected file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 5 }
|
|
|
|
mgnt2CnfRestoreConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Restore:This OID restores the
|
|
configuration of the specified module from the
|
|
selected file in MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 6 }
|
|
|
|
mgnt2CnfExportConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration Export:This OID exports the selected
|
|
file in MGNT2 FLASH to a file in RAM"
|
|
::= { mgnt2CnfManageConfigFilesEntry 7 }
|
|
|
|
|
|
mgnt2CnfDeleteConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Configuration delete from FLASH:This OID deletes the
|
|
configuration file from the MGNT2 FLASH"
|
|
::= { mgnt2CnfManageConfigFilesEntry 8 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Remote inventory
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2RinvHwPlatform OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Hardware inventory:This OID gives the
|
|
Hardware inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 1 }
|
|
|
|
mgnt2RinvSoftwarePackage OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Software package inventory:this OID gives
|
|
the Software package inventory of the Mgnt2
|
|
management module"
|
|
::= { mgnt2RemoteInventory 2 }
|
|
|
|
mgnt2RinvGateware OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Gateware inventory:This OID gives the
|
|
gateware inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 3 }
|
|
|
|
|
|
mgnt2RinvAgent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Software inventory:This OID gives the
|
|
software inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 4 }
|
|
|
|
mgnt2RinvCraft OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Craft inventory:This OID gives the
|
|
craft inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 5 }
|
|
|
|
mgnt2RinvLinux OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Chassis Linux inventory:This OID gives the
|
|
linux inventory of the Mgnt2 management module"
|
|
::= { mgnt2RemoteInventory 6 }
|
|
|
|
EkiPlugInState ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "Plug-in state"
|
|
SYNTAX INTEGER {
|
|
absent(0),
|
|
loaded(1),
|
|
versionError(2),
|
|
symbolError(3)
|
|
}
|
|
|
|
mgnt2GigmPlugInTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmPlugInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Plug-ins present"
|
|
::= { mgnt2RemoteInventory 7 }
|
|
|
|
mgnt2GigmPlugInEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmPlugInEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the Plug-ins table"
|
|
INDEX { mgnt2IndexPlugIns }
|
|
::= { mgnt2GigmPlugInTable 1 }
|
|
|
|
Mgnt2GigmPlugInEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexPlugIns
|
|
Integer32,
|
|
mgnt2PlugInRinv
|
|
DisplayString,
|
|
mgnt2PollingPresent
|
|
EkiPlugInState,
|
|
mgnt2SnmpPresent
|
|
EkiPlugInState
|
|
}
|
|
|
|
mgnt2IndexPlugIns OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for PMs table"
|
|
::= { mgnt2GigmPlugInEntry 1 }
|
|
|
|
|
|
mgnt2PlugInRinv OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Plug-in RI:This OID gives the remote inventory of the plug-in"
|
|
::= { mgnt2GigmPlugInEntry 2 }
|
|
|
|
mgnt2PollingPresent OBJECT-TYPE
|
|
SYNTAX EkiPlugInState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polling present:This OID gives the presence of the polling plug-in"
|
|
::= { mgnt2GigmPlugInEntry 3 }
|
|
|
|
mgnt2SnmpPresent OBJECT-TYPE
|
|
SYNTAX EkiPlugInState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Snmp present:This OID gives the presence of the snmp plug-in"
|
|
::= { mgnt2GigmPlugInEntry 4 }
|
|
|
|
mgnt2RinvBackpanel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Backpanel inventory:This OID gives the
|
|
Backpanel inventory of the chassis"
|
|
::= { mgnt2RemoteInventory 8 }
|
|
|
|
mgnt2RinvFan OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan inventory:This OID gives the
|
|
fan inventory of the chassis"
|
|
::= { mgnt2RemoteInventory 9 }
|
|
|
|
mgnt2RinvUboot OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"U-Boot inventory:This OID gives the
|
|
U-Boot inventory"
|
|
::= { mgnt2RemoteInventory 10 }
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Error counters
|
|
--
|
|
-- *****************************************************************
|
|
|
|
|
|
mgnt2GigmErrorCounterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2GigmErrorCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of error counters"
|
|
::= { mgnt2ErrorCounters 1 }
|
|
|
|
mgnt2GigmErrorCounterEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2GigmErrorCounterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the error counters table"
|
|
INDEX { mgnt2IndexErrorCounter }
|
|
::= { mgnt2GigmErrorCounterTable 1 }
|
|
|
|
Mgnt2GigmErrorCounterEntry ::=
|
|
SEQUENCE {
|
|
mgnt2IndexErrorCounter
|
|
Integer32,
|
|
mgnt2ErrorCounterSlotNumber
|
|
Integer32,
|
|
mgnt2ErrorCounterValue
|
|
Integer32
|
|
}
|
|
|
|
mgnt2IndexErrorCounter OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for error counters table"
|
|
::= { mgnt2GigmErrorCounterEntry 1 }
|
|
|
|
|
|
mgnt2ErrorCounterSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot number:This OID gives the slot number for the corresponding counter"
|
|
::= { mgnt2GigmErrorCounterEntry 2 }
|
|
|
|
mgnt2ErrorCounterValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count value:This OID gives the value of the error counter"
|
|
::= { mgnt2GigmErrorCounterEntry 3 }
|
|
|
|
|
|
mgnt2GigmResetErrorCounters OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset error counters:This OID reset the error counters to 0"
|
|
::= { mgnt2ErrorCounters 2 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Perf objects
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2PerfCapabilityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Mgnt2PerfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of Perf capability of PMs plugged in the Chassis"
|
|
::= { mgnt2Perf 1 }
|
|
|
|
mgnt2PerfCapabilityEntry OBJECT-TYPE
|
|
SYNTAX Mgnt2PerfCapabilityEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row Definition for the Perf capability table"
|
|
INDEX { mgnt2PerfCapIndexBoards }
|
|
::= { mgnt2PerfCapabilityTable 1 }
|
|
|
|
|
|
|
|
Mgnt2PerfCapabilityEntry ::=
|
|
SEQUENCE {
|
|
mgnt2PerfCapIndexBoards
|
|
Integer32,
|
|
mgnt2PerfCapPosition
|
|
Integer32,
|
|
mgnt2PerfCapName
|
|
DisplayString,
|
|
mgnt2PerfCapStatus
|
|
EkiOnOff,
|
|
mgnt2PerfCapOidEnable
|
|
OBJECT IDENTIFIER
|
|
}
|
|
|
|
|
|
mgnt2PerfCapIndexBoards OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for Perf cap table"
|
|
::= { mgnt2PerfCapabilityEntry 1 }
|
|
|
|
mgnt2PerfCapPosition OBJECT-TYPE
|
|
SYNTAX Integer32(1..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM Slot number:This OID gives the slot number in
|
|
which the PM is plugged"
|
|
::= { mgnt2PerfCapabilityEntry 2 }
|
|
|
|
mgnt2PerfCapName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PM name:This OID gives the name of the PM plugged
|
|
in the Mgnt2"
|
|
::= { mgnt2PerfCapabilityEntry 3 }
|
|
|
|
mgnt2PerfCapStatus OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the perf cap:This OID gives the capability
|
|
of the pm to do performance"
|
|
::= { mgnt2PerfCapabilityEntry 4 }
|
|
|
|
mgnt2PerfCapOidEnable OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OID of the object perf enable:This OID gives the OID of
|
|
the perf enable object of the correspondind mib of the module"
|
|
::= { mgnt2PerfCapabilityEntry 5 }
|
|
|
|
|
|
|
|
|
|
|
|
mgnt2GigmPerf15minSync OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 min sync perf : this oid send a 15min sync to all modules"
|
|
::= { mgnt2Perf 2 }
|
|
|
|
mgnt2GigmPerf24hSync OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"15 min sync perf : this oid send a 24h sync to all modules"
|
|
::= { mgnt2Perf 3 }
|
|
|
|
mgnt2PerfResyncNMS OBJECT-TYPE
|
|
SYNTAX Mgnt2PerfResyncValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Resync Perf : this oid allows to create an historical perf file for all modules"
|
|
::= { mgnt2Perf 4 }
|
|
|
|
|
|
-- *****************************************************************
|
|
--
|
|
-- MGNT2 Board management
|
|
--
|
|
-- *****************************************************************
|
|
|
|
mgnt2alarms OBJECT IDENTIFIER ::= { mgnt2Hardware 1}
|
|
mgnt2controls OBJECT IDENTIFIER ::= { mgnt2Hardware 2}
|
|
mgnt2config OBJECT IDENTIFIER ::= { mgnt2Hardware 3}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- ALARMS
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synthAlm0 article
|
|
--- *****************************************************
|
|
mgnt2AlmsynthAlm0 OBJECT IDENTIFIER ::= { mgnt2alarms 0 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmMgntDefFuseB OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Mgnt Fuse B Fail :This OID indicates
|
|
that the fuse of the power input
|
|
B is in fail condition on the Management
|
|
board <Help> Status of the MGNT
|
|
Fuse B <Condtype> MGNT_DEF_FUSE_B
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 16 }
|
|
|
|
|
|
|
|
mgnt2AlmMgntDefFuseA OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Mgnt Fuse A Fail :This OID indicates
|
|
that the fuse of the power input
|
|
A is in fail condition on the Management
|
|
board <Help> Status of the MGNT
|
|
Fuse A <Condtype> MGNT_DEF_FUSE_A
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 15 }
|
|
|
|
|
|
|
|
mgnt2AlmDef48b OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Power Input B Present :This OID
|
|
indicates that there is not input
|
|
power on the right power connector
|
|
(B) <Help> This alarm indicates
|
|
if the power input B is present
|
|
(right power connector) <Condtype>
|
|
DEF_48B <Probcause> powerProblem
|
|
(36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 12 }
|
|
|
|
|
|
|
|
mgnt2AlmDef48a OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Power Input A Present :This OID
|
|
indicates that there is not input
|
|
power on the right power connector
|
|
(A) <Help> This alarm indicates
|
|
if the power input B is present
|
|
(left power connector) <Condtype>
|
|
DEF_48A <Probcause> powerProblem
|
|
(36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 11 }
|
|
|
|
|
|
|
|
mgnt2AlmFansFailure OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Fan Module Failure :This
|
|
OID indicates that at least one
|
|
of the three FAN unit of the FAN
|
|
module is in fail condition <Condtype>
|
|
FANS_FAILURE <Probcause> other(1)
|
|
<Alarmtype> equipmentAlarm (5)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 10 }
|
|
|
|
|
|
|
|
mgnt2AlmAbsFailure OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Management Module Failure
|
|
:This OID indicates that the Chassis
|
|
Management module is in fail condition
|
|
<Condtype> ABS_FAILURE <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm0 9 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synthAlm1 article
|
|
--- *****************************************************
|
|
mgnt2AlmsynthAlm1 OBJECT IDENTIFIER ::= { mgnt2alarms 1 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmAcknowledge OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Alarm Ack. :This OID indicates
|
|
the alarms have been acknowledged
|
|
by the user (locally or remotely)
|
|
<Help> This status indicates
|
|
the alarms have been acknowledged
|
|
by the user (locally or remotely)
|
|
<Condtype> ACKNOWLEDGE <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 16 }
|
|
|
|
|
|
|
|
mgnt2AlmCritVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Critical Chassis Alarm :This OID
|
|
indicates at least one Critical
|
|
alarm is active on the complete
|
|
chassis (including TR-FAN, MGNT
|
|
and PM) <Help> This alarm indicates
|
|
at least one Critical alarm is
|
|
active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
|
|
<Condtype> CRIT_VISUAL <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmUrgVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Major Chassis Alarm :This OID
|
|
indicates at least one Major alarm
|
|
is active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
<Help> This alarm indicates
|
|
at least one Major alarm is active
|
|
on the complete chassis (including
|
|
TR-FAN, MGNT and PM) <Condtype>
|
|
URG_VISUAL <Probcause> other(1)
|
|
<Alarmtype> other (1) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 2 }
|
|
|
|
|
|
|
|
mgnt2AlmNurgVisual OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Minor Chassis Alarm :This OID
|
|
indicates at least one Minor alarm
|
|
is active on the complete chassis
|
|
(including TR-FAN, MGNT and PM)
|
|
<Help> This alarm indicates at
|
|
least one Minor alarm is active
|
|
on the complete chassis (including
|
|
TR-FAN, MGNT and PM) <Condtype>
|
|
NURG_VISUAL <Probcause> other(1)
|
|
<Alarmtype> other (1) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmsynthAlm1 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the boardMgmntSet1 article
|
|
--- *****************************************************
|
|
mgnt2AlmboardMgmntSet1 OBJECT IDENTIFIER ::= { mgnt2alarms 16 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPmFanAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN module present in Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module in the Chassis.
|
|
<Help> This alarm indicates if
|
|
the FAN module is detected in the
|
|
chassis. <Condtype> PM_FAN_ABSENT
|
|
<Probcause> other(1) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity>
|
|
(2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 14 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot11Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 11
|
|
:This OID indicates the presence
|
|
of a PM in Slot 11 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 11
|
|
<Condtype> PM_SLOT11_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 12 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot10Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 10
|
|
:This OID indicates the presence
|
|
of a PM in Slot 10 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 10
|
|
<Condtype> PM_SLOT10_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 11 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot9Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 9 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 9 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 9
|
|
<Condtype> PM_SLOT9_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 10 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot8Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 8 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 8 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 8
|
|
<Condtype> PM_SLOT8_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 9 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot7Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 7 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 7 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 7
|
|
<Condtype> PM_SLOT7_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 8 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot6Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 6 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 6 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 6
|
|
<Condtype> PM_SLOT6_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot5Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 5 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 5 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 5
|
|
<Condtype> PM_SLOT5_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot4Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 4 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 4 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 4
|
|
<Condtype> PM_SLOT4_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot3Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 3 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 3 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 3
|
|
<Condtype> PM_SLOT3_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot2Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 2 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 2 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 2
|
|
<Condtype> PM_SLOT2_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot1Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 1 :This
|
|
OID indicates the presence of a
|
|
PM in Slot 1 of the Chassis .
|
|
<Help> This status indicates
|
|
if a PM is detected in slot 1
|
|
<Condtype> PM_SLOT1_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet1 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the boardMgmntSet2 article
|
|
--- *****************************************************
|
|
mgnt2AlmboardMgmntSet2 OBJECT IDENTIFIER ::= { mgnt2alarms 17 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot20Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 20
|
|
:This OID indicates the presence
|
|
of a PM in Slot 20 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 20
|
|
<Condtype> PM_SLOT20_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 9 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot19Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 19
|
|
:This OID indicates the presence
|
|
of a PM in Slot 19 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 19
|
|
<Condtype> PM_SLOT19_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 8 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot18Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 18
|
|
:This OID indicates the presence
|
|
of a PM in Slot 18 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 18
|
|
<Condtype> PM_SLOT18_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot17Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 17
|
|
:This OID indicates the presence
|
|
of a PM in Slot 17 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 17
|
|
<Condtype> PM_SLOT17_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot16Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 16
|
|
:This OID indicates the presence
|
|
of a PM in Slot 16 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 16
|
|
<Condtype> PM_SLOT16_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot15Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 15
|
|
:This OID indicates the presence
|
|
of a PM in Slot 15 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 15
|
|
<Condtype> PM_SLOT15_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot14Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 14
|
|
:This OID indicates the presence
|
|
of a PM in Slot 14 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 14
|
|
<Condtype> PM_SLOT14_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot13Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 13
|
|
:This OID indicates the presence
|
|
of a PM in Slot 13 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 13
|
|
<Condtype> PM_SLOT13_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 2 }
|
|
|
|
|
|
|
|
mgnt2AlmPmSlot12Absent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PM present in Chassis slot 12
|
|
:This OID indicates the presence
|
|
of a PM in Slot 12 of the Chassis
|
|
. <Help> This status indicates
|
|
if a PM is detected in slot 12
|
|
<Condtype> PM_SLOT12_ABSENT <Probcause>
|
|
other(1) <Alarmtype> other (1)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmboardMgmntSet2 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the fanMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmfanMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 20 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFanFilterAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Dust Filter Presence :This OID
|
|
indicates that the dust filter
|
|
is not present<Help> This alarm
|
|
indicates if the Dust Filter is
|
|
detected in the chassis. <Condtype>
|
|
FAN_FILTER_ABSENT <Probcause> other(1)
|
|
<Alarmtype> equipmentAlarm (5)
|
|
<Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 16 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan6Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #6 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 6. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #6 is in fail condition
|
|
<Condtype> PB_FAN6_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 7 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan5Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #5 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 5. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #5 is in fail condition
|
|
<Condtype> PB_FAN5_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 6 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan4Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #4 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 4. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #4 is in fail condition
|
|
<Condtype> PB_FAN4_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 5 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan3Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #3 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 3. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #3 is in fail condition
|
|
<Condtype> PB_FAN3_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 4 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan2Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #2 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 2. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #2 is in fail condition
|
|
<Condtype> PB_FAN2_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 3 }
|
|
|
|
|
|
|
|
mgnt2AlmPbFan1Fail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Unit #1 Failed On Fan Module
|
|
:This OID indicates a failure on
|
|
fan 1. Removal of the fan unit
|
|
or no rotation sets the OID.
|
|
<Help> This alarm indicates if
|
|
the FAN #1 is in fail condition
|
|
<Condtype> PB_FAN1_FAIL <Probcause>
|
|
heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanMgmnt 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the fanPwrMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmfanPwrMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 24 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFanDefFuseB OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Fuse B Fail :This OID indicates
|
|
that the fuse of the power input
|
|
B is in fail condition on the Fan
|
|
board <Help> Status of the FAN
|
|
Fuse B <Condtype> FAN_DEF_FUSE_B
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 16 }
|
|
|
|
|
|
|
|
mgnt2AlmFanDefFuseA OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Fuse A Fail :This OID indicates
|
|
that the fuse of the power input
|
|
A is in fail condition on the Fan
|
|
board <Help> Status of the FAN
|
|
Fuse A <Condtype> FAN_DEF_FUSE_A
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 15 }
|
|
|
|
|
|
|
|
mgnt2AlmFanPwrFail1 OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Main Power :This OID indicates
|
|
a failure on the main power of
|
|
the FAN module <Help> This
|
|
alarm indicates if one of the
|
|
tow main power convert of the
|
|
FAN module is in fail condition
|
|
<Condtype> FAN_PWR_FAIL_1 <Probcause>
|
|
powerProblem (36) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 13 }
|
|
|
|
|
|
|
|
mgnt2AlmFanPwrProtOn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fan Backup Power :This OID indicates
|
|
the backup power on the FAN module
|
|
is switched on <Condtype> FAN_PWR_PROT_ON
|
|
<Probcause> powerProblem (36) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmfanPwrMgmnt 12 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the removeablefanModuleFail article
|
|
--- *****************************************************
|
|
mgnt2AlmremoveablefanModuleFail OBJECT IDENTIFIER ::= { mgnt2alarms 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFan4ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #4 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #4 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #4 is detected in the chassis.
|
|
<Condtype> FAN4_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 4 }
|
|
|
|
|
|
|
|
mgnt2AlmFan3ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #3 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #3 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #3 is detected in the chassis.
|
|
<Condtype> FAN3_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFan2ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #2 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #2 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #2 is detected in the chassis.
|
|
<Condtype> FAN2_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 2 }
|
|
|
|
|
|
|
|
mgnt2AlmFan1ModuleAbsent OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #1 Present In Chassis
|
|
:This OID indicates the presence
|
|
of the FAN module #1 in the Chassis.<Help>
|
|
This alarm indicates if the FAN
|
|
module #1 is detected in the chassis.
|
|
<Condtype> FAN1_MODULE_ABSENT <Probcause>
|
|
other(1) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveablefanModuleFail 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the removeableFanModuleMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmremoveableFanModuleMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 26 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmFan4ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #4 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#4 <Help> This alarm indicates
|
|
if the FAN module #4 is in fail
|
|
condition <Condtype> FAN4_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 4 }
|
|
|
|
|
|
|
|
mgnt2AlmFan3ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #3 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#3 <Help> This alarm indicates
|
|
if the FAN module #3 is in fail
|
|
condition <Condtype> FAN3_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFan2ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #2 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#2 <Help> This alarm indicates
|
|
if the FAN module #2 is in fail
|
|
condition <Condtype> FAN2_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 2 }
|
|
|
|
|
|
|
|
mgnt2AlmFan1ModuleFail OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FAN Module #1 Failure :This OID
|
|
indicates a failure on FAN module
|
|
#1 <Help> This alarm indicates
|
|
if the FAN module #1 is in fail
|
|
condition <Condtype> FAN1_MODULE_FAIL
|
|
<Probcause> heatingVentCoolingSystemProblem
|
|
(22) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmremoveableFanModuleMgmnt 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the swAlarm1 article
|
|
--- *****************************************************
|
|
mgnt2AlmswAlarm1 OBJECT IDENTIFIER ::= { mgnt2alarms 32 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmPollingManagerError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Polling Manager fail :This OID
|
|
indicates a failure on the Manager
|
|
polling the PM's <Help>
|
|
<Help> This alarm indicates if
|
|
there is a polling manager failure
|
|
between the MGNT and the Pm's <Condtype>
|
|
POLLING_MANAGER_ERROR <Probcause>
|
|
adapterError (2) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 3 }
|
|
|
|
|
|
|
|
mgnt2AlmFifoCmdError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
SNMP Agent to Transport comm FIFO
|
|
fail :This OID indicates a failure
|
|
inside the FIFO stack. The FIFO
|
|
containing the messages from
|
|
the agent (write) to the PMs is
|
|
full <Help> This alarm indicates
|
|
if there is a communication mismatch
|
|
between the MGNT board and all
|
|
PM <Condtype> FIFO_CMD_ERROR <Probcause>
|
|
adapterError (2) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 2 }
|
|
|
|
|
|
|
|
mgnt2AlmApiError OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Comm fail between Agent and Transport
|
|
:This OID indicates a failure detected
|
|
on the Agent.The failure is
|
|
located on a communication process
|
|
with the modules. <Help> This
|
|
alarm indicates if there is a communication
|
|
mismatch between the MGNT board
|
|
and a single PM <Condtype> API_ERROR
|
|
<Probcause> adapterError (2) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmswAlarm1 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the apiErrorCode article
|
|
--- *****************************************************
|
|
|
|
mgnt2AlmapiErrorCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
API Error Identification :Error
|
|
number and description of the abs1AlmApiError
|
|
object <Condtype> API_ERROR_CODE_1
|
|
<Probcause> <Alarmtype>
|
|
"
|
|
::= { mgnt2alarms 33 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logMgmnt article
|
|
--- *****************************************************
|
|
mgnt2AlmlogMgmnt OBJECT IDENTIFIER ::= { mgnt2alarms 34 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmLog80Full OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Full Warning :This OID
|
|
indicates that a log file is 80%
|
|
full. <Help> This alarm indicates
|
|
that one of the log file is 80%
|
|
Full <Condtype> LOG_80_FULL <Probcause>
|
|
fileError (18) <Alarmtype> equipmentAlarm
|
|
(5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmlogMgmnt 2 }
|
|
|
|
|
|
|
|
mgnt2AlmLogFileFull OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Full Alarm :This OID
|
|
indicates that a log file is full.
|
|
This file must be cleared to insure
|
|
correct log function <Help> This
|
|
alarm indicates that one of the
|
|
log file is Full <Condtype> LOG_FILE_FULL
|
|
<Probcause> fileError (18) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmlogMgmnt 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ntpSyncLoss article
|
|
--- *****************************************************
|
|
mgnt2AlmntpSyncLoss OBJECT IDENTIFIER ::= { mgnt2alarms 35 }
|
|
|
|
|
|
|
|
|
|
mgnt2AlmCpuTempOverRange OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CPU HighTemperature Warning :This
|
|
OID indicates a temperature over
|
|
the expected range on the CPU<Help>
|
|
This warning indicates that the
|
|
temperature of the CPU is reaching
|
|
its internal limit <Condtype> CPU_TEMP_OVER_RANGE
|
|
<Probcause> other(1) <Alarmtype>
|
|
equipmentAlarm (5) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmntpSyncLoss 2 }
|
|
|
|
|
|
|
|
mgnt2AlmNtpSyncLoss OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
NTP Sync Loss :This OID indicates
|
|
a loss of synchronisation with
|
|
the NTP Server. <Help> This
|
|
alarm indicates a loss of synchronisation
|
|
with the NTP Server. <Condtype>
|
|
NTP_SYNC_LOSS <Probcause> timingProblem
|
|
(53) <Alarmtype> timeDomainViolation
|
|
(11) <Polarity> (2)
|
|
"
|
|
::= { mgnt2AlmntpSyncLoss 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- CONTROLS
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the synth5 article
|
|
--- *****************************************************
|
|
mgnt2Ctrlsynth5 OBJECT IDENTIFIER ::= { mgnt2controls 5 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlChassisColdReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Cold Reset of the Management Module
|
|
:This oid triggers a 'cold' reset
|
|
of the Chassis . This type of reset
|
|
is not traffic affecting and the
|
|
modules configuration remains
|
|
unchanged. <Help> This control
|
|
initiates a cold reset of the MGNT
|
|
board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 4 }
|
|
|
|
|
|
|
|
mgnt2CtrlChassisWarmReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Reset of the Management Module
|
|
:This oid triggers a 'warm' reset
|
|
of the Chassis . This type of reset
|
|
is not traffic affecting and the
|
|
modules configuration remains
|
|
unchanged. <Help> This control
|
|
initiates a warm reset of the MGNT
|
|
board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 3 }
|
|
|
|
|
|
|
|
mgnt2CtrlChassisShutdown OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Shut Down of the Management Module
|
|
:This OID shall be set before shutting
|
|
down the Chassis power. A delay
|
|
of 5 sec is necessary between this
|
|
OID is set and power is shut down.
|
|
<Help> This control initiates
|
|
a shutdown of the MGNT board,
|
|
"
|
|
::= { mgnt2Ctrlsynth5 2 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the testLed article
|
|
--- *****************************************************
|
|
mgnt2CtrltestLed OBJECT IDENTIFIER ::= { mgnt2controls 18 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlLedOff OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Switch off Leds Test :This OID
|
|
switches off all the Leds as a
|
|
test feature <Help> This control
|
|
initiates a test leds turning all
|
|
the LEDs of the complete chassis
|
|
to OFF
|
|
"
|
|
::= { mgnt2CtrltestLed 3 }
|
|
|
|
|
|
|
|
mgnt2CtrlRedLed OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Red Leds Test :This OID switches
|
|
on all the red Leds as a test feature
|
|
<Help> This control initiates
|
|
a test leds turning all the LEDs
|
|
of the chassis to red
|
|
"
|
|
::= { mgnt2CtrltestLed 2 }
|
|
|
|
|
|
|
|
mgnt2CtrlGreenLed OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Green Leds Test :This OID switches
|
|
on all the green Leds as a test
|
|
feature <Help> This control initiates
|
|
a test leds turning all the LEDs
|
|
of the chassis to green
|
|
"
|
|
::= { mgnt2CtrltestLed 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logFile article
|
|
--- *****************************************************
|
|
mgnt2CtrllogFile OBJECT IDENTIFIER ::= { mgnt2controls 19 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlLogFileReset OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log File Reset :This OID clears
|
|
all the log files
|
|
"
|
|
::= { mgnt2CtrllogFile 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntSaveConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntSaveConfig OBJECT IDENTIFIER ::= { mgnt2controls 23 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlSaveConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Save Configuration :This OID is
|
|
used save the configuration related
|
|
to the enable and mode traps objects
|
|
<Help> This control saves the
|
|
customer configuration on the MGNT
|
|
board
|
|
"
|
|
::= { mgnt2CtrlmgntSaveConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntGetGlobalConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntGetGlobalConfig OBJECT IDENTIFIER ::= { mgnt2controls 24 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlGetGlobalConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Get Global Chassis Config :This
|
|
OID is used to create a global
|
|
configuration file of the chassis
|
|
<Help> This control creates a
|
|
single configuration file from
|
|
PM's and MGNT configuration file
|
|
into the RAM
|
|
"
|
|
::= { mgnt2CtrlmgntGetGlobalConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntPutGlobalConfig article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntPutGlobalConfig OBJECT IDENTIFIER ::= { mgnt2controls 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlPutGlobalConfig OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Put Global Chassis Config :This
|
|
OID is used to extract a global
|
|
configuration file of the chassis
|
|
<Help> This control creates configuration
|
|
files to PM's and MGNT from a
|
|
single configuration file in the
|
|
RAM
|
|
"
|
|
::= { mgnt2CtrlmgntPutGlobalConfig 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntAcknowledge article
|
|
--- *****************************************************
|
|
mgnt2CtrlmgntAcknowledge OBJECT IDENTIFIER ::= { mgnt2controls 26 }
|
|
|
|
|
|
|
|
|
|
mgnt2CtrlAcknowledge OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Alarm Ack. :This OID is used to
|
|
acknowledge the current active
|
|
alarms of the chassis <Help>
|
|
This control is used to acknowledge
|
|
the current active alarms of the
|
|
chassis
|
|
"
|
|
::= { mgnt2CtrlmgntAcknowledge 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- CONFIG
|
|
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
|
--- *****************************************************
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ethPort2 article
|
|
--- *****************************************************
|
|
mgnt2CfgethPort2 OBJECT IDENTIFIER ::= { mgnt2config 17 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgChassisEthernetSplit OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Chassis Ethernet Split :This
|
|
OID enables the split between
|
|
the two kendings. <Help> Enable/Disable
|
|
the switch between the two kendings
|
|
"
|
|
::= { mgnt2CfgethPort2 2 }
|
|
|
|
|
|
|
|
mgnt2CfgEthPort2Disable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
2nd Ethernet Port Disable :This
|
|
OID disables 'Ethernet Port 2'
|
|
.When not required, this port
|
|
must be disabled in order to
|
|
prevent unwanted access. <Help>
|
|
Disable the second Ethernet port
|
|
"
|
|
::= { mgnt2CfgethPort2 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntDccEnable article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmgntDccEnable OBJECT-TYPE
|
|
SYNTAX Mgnt2DccAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DCC Access :This OID selects
|
|
the mode to enable the DCC on
|
|
the slots. This Mode enables the
|
|
Slots 2-4-6-8-10 , or the Slots
|
|
2-6-10-14-18. <Help> Defines
|
|
the DCC access on the backplane
|
|
of the chassis (Slots 2-4-6-8-10
|
|
or Slots 2-6-10-14-18)
|
|
"
|
|
::= { mgnt2config 18 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the pmTrapEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgpmTrapEnable OBJECT IDENTIFIER ::= { mgnt2config 20 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgPmConfigTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Config Traps Enable :This OID,
|
|
when set, enables the generation
|
|
of a trap when the configuration
|
|
of a PM plugged in the chassis
|
|
is modified <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on PM configuration modificatio
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 6 }
|
|
|
|
|
|
|
|
mgnt2CfgPmControlTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Control Traps Enable :This OID,
|
|
when set, enables the generation
|
|
of a trap when a control is sent
|
|
to a PM plugged in the chassis
|
|
|
|
<Help> In detailed traps
|
|
mechanism, enable the trap emission
|
|
on control sent to PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 5 }
|
|
|
|
|
|
|
|
mgnt2CfgPmMinorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Minor Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the minor alarm trap for all
|
|
the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on minor
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgPmMajorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Major Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the major alarm trap for all
|
|
the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on major
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgPmCriticalTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Critical Alarm Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the critical alarm trap for
|
|
all the PM plugged in the chassis
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on critical
|
|
alarm detected on PM
|
|
"
|
|
::= { mgnt2CfgpmTrapEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntTrapEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgmgntTrapEnable OBJECT IDENTIFIER ::= { mgnt2config 21 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgMgntEventTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Event Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when an event occurs
|
|
on the chassis <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on event detected in the
|
|
chassis
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 7 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntConfigTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Config Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when the configuration
|
|
of a MGNT plugged in the chassis
|
|
is modified <Help> In detailed
|
|
traps mechanism, enable the trap
|
|
emission on MGNT configuration
|
|
modification
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 6 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntControlTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Control Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of a trap when a control is sent
|
|
to a MGNT plugged in the chassis
|
|
|
|
<Help> In detailed traps
|
|
mechanism, enable the trap emission
|
|
on control sent to MGNT
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 5 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntMinorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Minor Alarm Traps Enable
|
|
:This OID, when set, enables the
|
|
generation of the minor alarm trap
|
|
for the MGNT and FAN board <Help>
|
|
In detailed traps mechanism, enable
|
|
the trap emission on minor alarm
|
|
detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntMajorTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Major Traps Enable :This
|
|
OID, when set, enables the generation
|
|
of the major alarm trap for the
|
|
MGNT and FAN board <Help> In
|
|
detailed traps mechanism, enable
|
|
the trap emission on major alarm
|
|
detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgMgntCriticalTrapEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
MGNT Critical Alarm Traps Enable
|
|
:This OID, when set, enables the
|
|
generation of the critical alarm
|
|
trap for the MGNT and FAN board
|
|
<Help> In detailed traps mechanism,
|
|
enable the trap emission on critical
|
|
alarm detected on MGNT and FAN
|
|
"
|
|
::= { mgnt2CfgmgntTrapEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the mgntTrapMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmgntTrapMode OBJECT-TYPE
|
|
SYNTAX Mgnt2TrapModeValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Traps Mode :This OID is used to
|
|
define the trap mode (synthetic
|
|
or detailed mode) <Help> Selects
|
|
the traps mechanism
|
|
"
|
|
::= { mgnt2config 22 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the syslogEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgsyslogEnable OBJECT IDENTIFIER ::= { mgnt2config 23 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgSyslogAlarmEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Alarm Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when an alarm occurs
|
|
<Help> Enable a syslog emission
|
|
on an alarm detected on the chassi
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 4 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogCtrlEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Control Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when a control is
|
|
set <Help> Enable a syslog
|
|
emission on a control operated
|
|
on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 3 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogConfigEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Config Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when the configuration
|
|
has been changed. <Help> Enable
|
|
a syslog emission on a configuration
|
|
change detected on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgSyslogEventEn OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Syslog Event Enable :This OID,
|
|
when set, enables the generation
|
|
of a syslog, when an event has
|
|
been detected <Help> Enable
|
|
a syslog emission on event detected
|
|
on the chassis
|
|
"
|
|
::= { mgnt2CfgsyslogEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ntpTimeZone article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgntpTimeZone OBJECT-TYPE
|
|
SYNTAX INTEGER (-12..12)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
NTP Time Zone :This OID defines
|
|
the time zone of the MGNT board
|
|
for the NTP server <Help> This
|
|
object defines the time zone of
|
|
the MGNT board (from -12 to +12
|
|
hours from the GMT).
|
|
"
|
|
::= { mgnt2config 24 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the pmConfEnable article
|
|
--- *****************************************************
|
|
mgnt2CfgpmConfEnable OBJECT IDENTIFIER ::= { mgnt2config 25 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgPmRestoreEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Automatic Config Restore :This
|
|
OID enables the automatic PM configuration
|
|
restore mechanism on PM insertion
|
|
<Help> This parameter enables
|
|
the automatic PM configuration
|
|
restore mechanism on PM insertio
|
|
"
|
|
::= { mgnt2CfgpmConfEnable 2 }
|
|
|
|
|
|
|
|
mgnt2CfgPmBackupEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Automatic Config Backup :This
|
|
OID enables the automatic PM configuration
|
|
backup mechanism on PM insertion
|
|
or PM configuration modification.
|
|
<Help> This parameter enables
|
|
the automatic PM configuration
|
|
backup mechanism on PM insertion
|
|
or PM configuration modificatio
|
|
"
|
|
::= { mgnt2CfgpmConfEnable 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the inactivityTimeout article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfginactivityTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Idle Timeout :This OID defines
|
|
the idle timeout (in minutes) to
|
|
automatically logout from the craft
|
|
and from the CLI. <Help> This
|
|
object defines the idle timeout
|
|
(in minutes) to automatically logout
|
|
from the craft and from the CLI
|
|
"
|
|
::= { mgnt2config 26 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the cliAccess article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgcliAccess OBJECT-TYPE
|
|
SYNTAX Mgnt2CliAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CLI access :This OID selects
|
|
the protocol for the remote access
|
|
to a CLI user. <Help> This object
|
|
defines the protocol used for a
|
|
remote CLI.
|
|
"
|
|
::= { mgnt2config 27 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the craftAccess article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgcraftAccess OBJECT-TYPE
|
|
SYNTAX Mgnt2CraftAccessValues
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
CRAFT access :This OID selects
|
|
the remote access to a CRAFT user.
|
|
<Help> This object defines the
|
|
access for a remote CRAFT.
|
|
"
|
|
::= { mgnt2config 28 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the perfModes1 article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgperfModes1 OBJECT-TYPE
|
|
SYNTAX EkiSynchroMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
PERF Synchro Source :This OID
|
|
selects the source of the synchronisation
|
|
(Internal/External). <Help> This
|
|
object defines the source of the
|
|
synchronization to operate performance
|
|
monitoring.
|
|
"
|
|
::= { mgnt2config 29 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the alarmModelActiv article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgalarmModelActiv OBJECT-TYPE
|
|
SYNTAX Mgnt2AckMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Acknowledge mode :This OID defines
|
|
the alarms akcnowledge mode <Help>
|
|
This configuration defines the
|
|
alarms akcnowledge mode
|
|
"
|
|
::= { mgnt2config 30 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the networkInput article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgnetworkInput OBJECT-TYPE
|
|
SYNTAX Mgnt2NetMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Network input :This OID selects
|
|
the connection of the Ethernet
|
|
Network input to either the switches
|
|
(2) or the daughter board (1) ,
|
|
in this case the MGNT can act as
|
|
a router <Help> This configuration
|
|
defines the use of the Network
|
|
input of the front panel
|
|
"
|
|
::= { mgnt2config 31 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the masterEthMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgmasterEthMode OBJECT-TYPE
|
|
SYNTAX Mgnt2MasterEthMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DHCP Master Ethernet Mode :This
|
|
OID selects the mode of the Master
|
|
Ethernet in DHCP mode (2) or in
|
|
Static Mode(1) <Help> This configuration
|
|
defines the use of the Master Ethernet
|
|
Mode
|
|
"
|
|
::= { mgnt2config 32 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the subnetMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgsubnetMode OBJECT-TYPE
|
|
SYNTAX Mgnt2SubnetEthMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
DHCP Subnet Mode :This OID selects
|
|
the mode of the Subnet in DHCP
|
|
mode (2) or in Static Mode(1)
|
|
<Help> This configuration defines
|
|
the use of the Subnet Mode
|
|
"
|
|
::= { mgnt2config 33 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the rstpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgrstpMode OBJECT IDENTIFIER ::= { mgnt2config 34 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgRstpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
RSTP Enable :This OID enables
|
|
the RSTP algorythm <Help> This
|
|
configuration defines the use of
|
|
RSTP
|
|
"
|
|
::= { mgnt2CfgrstpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the lldpMode article
|
|
--- *****************************************************
|
|
mgnt2CfglldpMode OBJECT IDENTIFIER ::= { mgnt2config 35 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgLldpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
LLDP Enable :This OID enables
|
|
the LLDP algorythm <Help> This
|
|
configuration defines the use of
|
|
LLDP
|
|
"
|
|
::= { mgnt2CfglldpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the logMode article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfglogMode OBJECT-TYPE
|
|
SYNTAX Mgnt2LogFileMode
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Log Mode :This OID enables the
|
|
log file mode<Help> This configuration
|
|
defines the use of the log mod
|
|
"
|
|
::= { mgnt2config 36 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the nodeMode article
|
|
--- *****************************************************
|
|
mgnt2CfgnodeMode OBJECT IDENTIFIER ::= { mgnt2config 37 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgNodeControllerEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Node Controller Mode :This OID
|
|
enables the node controller mode<Help>
|
|
This configuration defines the
|
|
use of the node controller mod
|
|
"
|
|
::= { mgnt2CfgnodeMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the unprivilegedUsersMode article
|
|
--- *****************************************************
|
|
mgnt2CfgunprivilegedUsersMode OBJECT IDENTIFIER ::= { mgnt2config 38 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgRestrictUnprivilegeUsers OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Restrict Unprivileged Users Rights
|
|
:This OID enables the restriction
|
|
of unprivileged user rights to
|
|
modify their own password <Help>
|
|
This parameter enables the restriction
|
|
of unprivileged user rights to
|
|
modify their own password
|
|
"
|
|
::= { mgnt2CfgunprivilegedUsersMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the oscDccLinkUpThreshold article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgoscDccLinkUpThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
OSC/DCC Link Up Thresh. [10-30]s
|
|
:This OID defines the confirmation
|
|
threshold to consider an OSC/DCC
|
|
link as up <Help> This parameter
|
|
defines the confirmation threshold
|
|
to consider an OSC/DCC link as
|
|
up
|
|
"
|
|
::= { mgnt2config 39 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the oscDccLinkDownThreshold article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgoscDccLinkDownThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
OSC/DCC Link Down Thresh. [2-3]s
|
|
:This OID defines the confirmation
|
|
threshold to consider an OSC/DCC
|
|
link as down <Help> This parameter
|
|
defines the confirmation threshold
|
|
to consider an OSC/DCC link as
|
|
down.
|
|
"
|
|
::= { mgnt2config 40 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the accountAutoLock article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgaccountAutoLock OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Account Auto-Lock [-1 / 1-10]
|
|
err :This OID defines the number
|
|
of error password to lock an account.
|
|
This counter is reset on successful
|
|
login or after an administrator
|
|
defined period (see Fail count
|
|
reset) Set to -1 to disables the
|
|
feature.<Help> This parameter defines
|
|
the number of error password to
|
|
lock an account. This counter is
|
|
reset on successful login or after
|
|
an administrator defined period
|
|
(see Fail count reset) Set to -1
|
|
to disables the feature.
|
|
"
|
|
::= { mgnt2config 41 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the failCountReset article
|
|
--- *****************************************************
|
|
|
|
mgnt2CfgfailCountReset OBJECT-TYPE
|
|
SYNTAX INTEGER (-1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
Fail Count Reset [-1 / 1-10] hrs
|
|
:This OID defines the minimum time
|
|
(in hours) to reset the failed
|
|
login counter. This counter is
|
|
also reset on successful login.
|
|
Set to -1 to disable the feature.<Help>
|
|
This parameter defines the minimum
|
|
time (in hours) to reset the failed
|
|
login counter. This counter is
|
|
also reset on successful login.
|
|
Set to -1 to disable the feature
|
|
"
|
|
::= { mgnt2config 42 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the ftpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgftpMode OBJECT IDENTIFIER ::= { mgnt2config 44 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgFtpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
FTP Enable :This OID enables the
|
|
FTP protocol <Help> This configuration
|
|
enables the FTP protocol
|
|
"
|
|
::= { mgnt2CfgftpMode 1 }
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- LEAF for the tftpMode article
|
|
--- *****************************************************
|
|
mgnt2CfgtftpMode OBJECT IDENTIFIER ::= { mgnt2config 45 }
|
|
|
|
|
|
|
|
|
|
mgnt2CfgTftpEnable OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"
|
|
TFTP Enable :This OID enables
|
|
the TFTP protocol <Help> This
|
|
configuration enables the TFTP
|
|
protocol
|
|
"
|
|
::= { mgnt2CfgtftpMode 1 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
--- *****************************************************
|
|
--- TRAPS
|
|
--- *****************************************************
|
|
|
|
mgnt2TrapBoardNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the slot number of the PM that sent the last trap"
|
|
::= { mgnt2Traps 50 }
|
|
|
|
mgnt2TrapSeverity OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the trap severity"
|
|
::= { mgnt2Traps 51 }
|
|
|
|
mgnt2TrapSourcePm OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the mnemonic of the pm who sent a trap"
|
|
::= { mgnt2Traps 52 }
|
|
|
|
mgnt2TrapSourcePortType OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the type of the port who sent a trap"
|
|
::= { mgnt2Traps 53 }
|
|
|
|
mgnt2TrapSourcePortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER(1..16)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the port number of the PM that sent the last trap"
|
|
::= { mgnt2Traps 54 }
|
|
|
|
mgnt2TrapSourceLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the label of the alarm who sent a trap"
|
|
::= { mgnt2Traps 55 }
|
|
|
|
mgnt2TrapSourceValue OBJECT-TYPE
|
|
SYNTAX EkiOnOff
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the value of the alarm who sent a trap"
|
|
::= { mgnt2Traps 56 }
|
|
|
|
mgnt2TrapEventLabel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the label of the event"
|
|
::= { mgnt2Traps 57 }
|
|
|
|
mgnt2TrapNodeControllerIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the IP address of the Node Controller"
|
|
::= { mgnt2Traps 58 }
|
|
|
|
mgnt2TrapChassisId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This OID gives the chassis ID "
|
|
::= { mgnt2Traps 59 }
|
|
|
|
mgnt2TrapApi NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber,mgnt2AlmapiErrorCode}
|
|
STATUS current
|
|
--&FILTNAME "API Error"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmapiErrorCode "$2"}
|
|
--&MESG "API Error number $2 received from Board in slot $1 ($A)"
|
|
DESCRIPTION "Api error trap with its number"
|
|
::= { mgnt2Traps 1 }
|
|
|
|
mgnt2TrapSwError NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmFifoCmdError}
|
|
STATUS current
|
|
--&FILTNAME "SW Error"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2AlmFifoCmdError "$1"}
|
|
--&MESG "Software Error detected"
|
|
DESCRIPTION "Chassis software error other API"
|
|
::= { mgnt2Traps 2 }
|
|
|
|
mgnt2TrapBoardInserted NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Board Inserted"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "Board Inserted in Slot $1 ($A)"
|
|
DESCRIPTION "A board has been plugged in"
|
|
::= { mgnt2Traps 4}
|
|
|
|
mgnt2TrapBoardRemoved NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Board Removed"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "Board Removed from Slot $1 ($A)"
|
|
DESCRIPTION "A board has been plugged out"
|
|
::= { mgnt2Traps 5 }
|
|
|
|
mgnt2TrapRestoreConfDone NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber}
|
|
STATUS current
|
|
--&FILTNAME "Config Restored"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1"}
|
|
--&MESG "The Configuration of Board in Slot $1 has been restored ($A)"
|
|
DESCRIPTION "The Configuration has been restored from the management board"
|
|
::= { mgnt2Traps 6 }
|
|
|
|
mgnt2TrapGlobalPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmDef48b, mgnt2AlmDef48a}
|
|
STATUS current
|
|
--&FILTNAME "Power A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmDef48b "off", mgnt2AlmDef48a "on"}
|
|
--&MESG "Power Input A Fail on Chassis ($A)"
|
|
|
|
--&FILTNAME "Power B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmDef48b "on", mgnt2AlmDef48a "off"}
|
|
--&MESG "Power Input B Fail on Chassis ($A)"
|
|
|
|
--&FILTNAME "Power A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "Power A Fail ON", "Power B Fail ON"}
|
|
--&MATCH { mgnt2AlmDef48b "off", mgnt2AlmDef48a "off"}
|
|
--&MESG "Power Input A and B Present on Chassis ($A)"
|
|
|
|
DESCRIPTION "A global power supply failure has been detected"
|
|
::= { mgnt2Traps 8 }
|
|
|
|
mgnt2TrapFanPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmFanDefFuseB , mgnt2AlmFanDefFuseA, mgnt2AlmFanPwrFail1}
|
|
STATUS current
|
|
--&FILTNAME "FAN Fuse A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "on", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input A Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "on", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input B Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse A and B Fail ON"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "on", mgnt2AlmFanDefFuseA "on", mgnt2AlmFanPwrFail1 "*"}
|
|
--&MESG "Power Input A and B Fail on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Fuse A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "FAN Fuse A Fail ON", "FAN Fuse B Fail ON", "FAN Fuse A and B Fail ON"}
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "off"}
|
|
--&MESG "Power Input A and B Present on FAN ($A)"
|
|
|
|
--&FILTNAME "FAN Power Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmFanDefFuseB "off", mgnt2AlmFanDefFuseA "off", mgnt2AlmFanPwrFail1 "on"}
|
|
--&MESG "Power Converter Fail on FAN ($A)"
|
|
|
|
DESCRIPTION "A Fan power supply failure has been detected"
|
|
::= { mgnt2Traps 9 }
|
|
|
|
mgnt2TrapGigmPowerFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmMgntDefFuseA, mgnt2AlmMgntDefFuseB}
|
|
STATUS current
|
|
--&FILTNAME "Fuse B Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "off", mgnt2AlmMgntDefFuseB "on"}
|
|
--&MESG "Power Input B Fail on MGNT ($A)"
|
|
|
|
--&FILTNAME "Fuse A Fail ON"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "on", mgnt2AlmMgntDefFuseB "off"}
|
|
--&MESG "Power Input A Fail on MGNT ($A)"
|
|
|
|
--&FILTNAME "Fuse A and B Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "Fuse B Fail ON", "Fuse A Fail ON"}
|
|
--&MATCH { mgnt2AlmMgntDefFuseA "off", mgnt2AlmMgntDefFuseB "off"}
|
|
--&MESG "Power Input A and B Present on MGNT ($A)"
|
|
|
|
DESCRIPTION "A power supply default has been detected in the management board"
|
|
::= { mgnt2Traps 10 }
|
|
|
|
mgnt2TrapFanFail NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2AlmPbFan1Fail, mgnt2AlmPbFan2Fail, mgnt2AlmPbFan3Fail, mgnt2AlmPbFan4Fail, mgnt2AlmPbFan5Fail, mgnt2AlmPbFan6Fail}
|
|
STATUS current
|
|
--&FILTNAME "All trap Fail"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "on", mgnt2AlmPbFan2Fail "on", mgnt2AlmPbFan3Fail "on", mgnt2AlmPbFan4Fail "on", mgnt2AlmPbFan5Fail "on", mgnt2AlmPbFan6Fail "on"}
|
|
--&MESG "The FAN tray is in Failure condition (all FAN fail) ($A)"
|
|
|
|
--&FILTNAME "FAN 1 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "on", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 1 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 2 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "on", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 2 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 3 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "on", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 3 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 4 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "on", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 4 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 5 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "on", mgnt2AlmPbFan6Fail "*"}
|
|
--&MESG "Fan number 5 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN 6 Fail"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2AlmPbFan1Fail "*", mgnt2AlmPbFan2Fail "*", mgnt2AlmPbFan3Fail "*", mgnt2AlmPbFan4Fail "*", mgnt2AlmPbFan5Fail "*", mgnt2AlmPbFan6Fail "on"}
|
|
--&MESG "Fan number 6 Fail on FAN Module ($A)"
|
|
|
|
--&FILTNAME "FAN Fail OFF"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "All trap Fail"}
|
|
--&MATCH { mgnt2AlmPbFan1Fail "off", mgnt2AlmPbFan2Fail "off", mgnt2AlmPbFan3Fail "off", mgnt2AlmPbFan4Fail "off", mgnt2AlmPbFan5Fail "off", mgnt2AlmPbFan6Fail "off"}
|
|
--&MESG "The FAN tray is fully operational (no FAN fail)"
|
|
|
|
DESCRIPTION "A Fan failure has been detected"
|
|
::= { mgnt2Traps 11 }
|
|
|
|
mgnt2TrapLogFileFull NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber, mgnt2AlmLog80Full, mgnt2AlmLogFileFull}
|
|
STATUS current
|
|
--&FILTNAME "Log almost full"
|
|
--&ACTIONS { log, warning }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmLog80Full "on", mgnt2AlmLogFileFull "off"}
|
|
--&MESG "The log of Board in slot $1 is 80% full ($A)"
|
|
|
|
--&FILTNAME "Log Full"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2TrapBoardNumber "$1", mgnt2AlmLog80Full "*", mgnt2AlmLogFileFull "on"}
|
|
--&MESG "The log of Board in slot $1 is Full ($A)"
|
|
DESCRIPTION "Indicates that the corresponding log file is almost full"
|
|
::= { mgnt2Traps 20 }
|
|
|
|
mgnt2TrapAlarm NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSeverity, mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "critical clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "critical detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Critical", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "critical detect"
|
|
--&ACTIONS { log, critical }
|
|
--&MATCH { mgnt2TrapSeverity "Critical", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "major clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "major detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Major", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "major detect"
|
|
--&ACTIONS { log, major }
|
|
--&MATCH { mgnt2TrapSeverity "Major", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "minor clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "minor detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Minor", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "minor detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Minor", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "warning clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "warning detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Warning", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "warning detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Warning", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "indeterminate clear"
|
|
--&ACTIONS { log, normal }
|
|
--&CLEARS { "indeterminate detect" }
|
|
--&MATCH { mgnt2TrapSeverity "Indeterminate", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "off" }
|
|
--&MESG "$1 Alarms ($6) cleared on $2 (Slot $3) on $4 ($A)"
|
|
|
|
--&FILTNAME "indeterminate detect"
|
|
--&ACTIONS { log, minor }
|
|
--&MATCH { mgnt2TrapSeverity "Indeterminate", mgnt2TrapSourcePm "$2", mgnt2TrapBoardNumber "$3", mgnt2TrapSourcePortType "$4", mgnt2TrapSourcePortNumber "$5", mgnt2TrapSourceLabel "$6", mgnt2TrapSourceValue "on" }
|
|
--&MESG "$1 Alarms ($6) detected on $2 (Slot $3) on $4 ($A)"
|
|
DESCRIPTION "Indicates that an alarm state has changed"
|
|
::= { mgnt2Traps 30 }
|
|
|
|
mgnt2TrapEvent NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapBoardNumber, mgnt2TrapEventLabel, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "event"
|
|
--&ACTIONS { log, info }
|
|
--&CLEARS { "critical detect" }
|
|
--&MATCH {mgnt2TrapBoardNumber "$1", mgnt2TrapEventLabel "$2" }
|
|
--&MESG "$2 (Slot $1) ($A)"
|
|
DESCRIPTION "Indicates that an event has occured"
|
|
::= { mgnt2Traps 31 }
|
|
|
|
mgnt2TrapControl NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "control sent"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapSourcePm "$1", mgnt2TrapBoardNumber "$2", mgnt2TrapSourcePortType "$3", mgnt2TrapSourcePortNumber "$4", mgnt2TrapSourceLabel "$5" }
|
|
--&MESG "Controls ($5) has been set to $6 on $1 (Slot $2) on $3 ($A)"
|
|
|
|
DESCRIPTION "Indicates that a control has been set to the module"
|
|
::= { mgnt2Traps 32 }
|
|
|
|
mgnt2TrapConfig NOTIFICATION-TYPE
|
|
OBJECTS {mgnt2TrapSourcePm, mgnt2TrapBoardNumber, mgnt2TrapSourcePortType, mgnt2TrapSourcePortNumber, mgnt2TrapSourceLabel, mgnt2TrapSourceValue, mgnt2TrapNodeControllerIpAddress,mgnt2TrapChassisId}
|
|
STATUS current
|
|
--&FILTNAME "config sent"
|
|
--&ACTIONS { log, info }
|
|
--&MATCH { mgnt2TrapSourcePm "$1", mgnt2TrapBoardNumber "$2", mgnt2TrapSourcePortType "$3", mgnt2TrapSourcePortNumber "$4", mgnt2TrapSourceLabel "$5"}
|
|
--&MESG "Config Word ($5) has been set to $6 on $1 (Slot $2) on $3 ($A)"
|
|
|
|
DESCRIPTION "Indicates that a config word has been changed"
|
|
::= { mgnt2Traps 33 }
|
|
|
|
|
|
|
|
|
|
|
|
|
|
END
|