- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
643 lines
22 KiB
Text
643 lines
22 KiB
Text
EdgeSwitch-BOXSERVICES-PRIVATE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Broadcom Inc EdgeSwitch Box Services MIB
|
|
-- Copyright Broadcom Inc(2004-2008) All rights reserved.
|
|
|
|
-- This SNMP Management Information Specification
|
|
-- embodies Broadcom Inc's confidential and proprietary
|
|
-- intellectual property. Broadcom Inc retains all title
|
|
-- and ownership in the Specification including any revisions.
|
|
|
|
-- This Specification is supplied "AS IS", Broadcom Inc
|
|
-- makes no warranty, either expressed or implied,
|
|
-- as to the use, operation, condition, or performance of the
|
|
-- Specification.
|
|
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32, Integer32 FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
DisplayString FROM RFC1213-MIB
|
|
fastPath FROM EdgeSwitch-REF-MIB;
|
|
|
|
fastPathBoxServices MODULE-IDENTITY
|
|
LAST-UPDATED "201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
|
ORGANIZATION "Broadcom Inc"
|
|
CONTACT-INFO ""
|
|
|
|
DESCRIPTION
|
|
"The Ubiquiti Private MIB for EdgeSwitch Box Services Feature."
|
|
|
|
-- Revision history.
|
|
REVISION
|
|
"201101260000Z" -- 26 Jan 2011 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Postal address updated."
|
|
REVISION
|
|
"200802220000Z" -- 22 Feb 2008 12:00:00 GMT
|
|
DESCRIPTION
|
|
"Ubiquiti branding related changes."
|
|
|
|
::= { fastPath 43 }
|
|
|
|
BoxsTemperatureStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature state"
|
|
SYNTAX INTEGER {
|
|
low(0),
|
|
normal(1),
|
|
warning(2),
|
|
critical(3),
|
|
shutdown(4),
|
|
notpresent(5),
|
|
notoperational(6)
|
|
}
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesGroup
|
|
--
|
|
-- This group provides configuration and status of the Box Services
|
|
-- feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxServicesGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 1 }
|
|
|
|
--**************************************************************************************
|
|
-- Some scalars
|
|
|
|
boxServicesNormalTempRangeMin OBJECT-TYPE
|
|
SYNTAX Integer32 (-100..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Lower boundary of normal temperature range."
|
|
DEFVAL { 0 }
|
|
::= { boxServicesGroup 1 }
|
|
|
|
boxServicesNormalTempRangeMax OBJECT-TYPE
|
|
SYNTAX Integer32 (-100..100)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Upper boundary of normal temperature range."
|
|
DEFVAL { 45 }
|
|
::= { boxServicesGroup 2 }
|
|
|
|
boxServicesTemperatureTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable temperature change event trap, raised when temperature crosses boundaries of normal range"
|
|
DEFVAL { enable }
|
|
::= { boxServicesGroup 3 }
|
|
|
|
boxServicesPSMStateTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable Power Supply Module state change trap."
|
|
DEFVAL { enable }
|
|
::= { boxServicesGroup 4 }
|
|
|
|
boxServicesFanStateTrapEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable or disable Fan state change trap."
|
|
DEFVAL { enable }
|
|
::= { boxServicesGroup 5 }
|
|
|
|
|
|
|
|
boxServicesThermalShutdownSensor OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the sensor which initiated thermal shutdown."
|
|
|
|
::= { boxServicesGroup 13 }
|
|
|
|
boxServicesThermalShutdownTemperature OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature of the sensor which initiated thermal shutdown."
|
|
|
|
::= { boxServicesGroup 14 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesFans
|
|
|
|
boxServicesFansTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesFansEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan"
|
|
::= { boxServicesGroup 6 }
|
|
|
|
boxServicesFansEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesFansEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Fan Entry"
|
|
INDEX { boxServicesFanUnitIndex , boxServicesFansIndex }
|
|
::= { boxServicesFansTable 1 }
|
|
|
|
BoxServicesFansEntry ::= SEQUENCE {
|
|
boxServicesFanUnitIndex
|
|
Unsigned32,
|
|
boxServicesFansIndex
|
|
Integer32,
|
|
boxServicesFanItemType
|
|
INTEGER,
|
|
boxServicesFanItemState
|
|
INTEGER,
|
|
boxServicesFanSpeed
|
|
OCTET STRING,
|
|
boxServicesFanDutyLevel
|
|
OCTET STRING
|
|
}
|
|
|
|
boxServicesFanUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Fan Table"
|
|
::= { boxServicesFansEntry 6 }
|
|
|
|
boxServicesFansIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of fan table entry"
|
|
::= { boxServicesFansEntry 1 }
|
|
|
|
boxServicesFanItemType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of fan"
|
|
::= { boxServicesFansEntry 2 }
|
|
|
|
|
|
boxServicesFanItemState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notpresent(1),
|
|
operational(2),
|
|
failed(3),
|
|
powering(4),
|
|
nopower(5),
|
|
notpowering(6),
|
|
incompatible(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of fan. nopower(4) - This state means the fan is present but no AC is connected."
|
|
::= { boxServicesFansEntry 3 }
|
|
|
|
|
|
boxServicesFanSpeed OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (13))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The speed of fan"
|
|
::= { boxServicesFansEntry 4}
|
|
|
|
boxServicesFanDutyLevel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (13))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The duty level of fan, in percents"
|
|
::= { boxServicesFansEntry 5}
|
|
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesPowSupplies
|
|
|
|
boxServicesPowSuppliesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesPowSuppliesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power supply"
|
|
::= { boxServicesGroup 7 }
|
|
|
|
boxServicesPowSuppliesEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesPowSuppliesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Power Supply Entry"
|
|
INDEX { boxServicesPowerSuppUnitIndex, boxServicesPowSupplyIndex }
|
|
::= { boxServicesPowSuppliesTable 1 }
|
|
|
|
BoxServicesPowSuppliesEntry ::= SEQUENCE {
|
|
boxServicesPowerSuppUnitIndex
|
|
Unsigned32,
|
|
boxServicesPowSupplyIndex
|
|
Integer32,
|
|
boxServicesPowSupplyItemType
|
|
INTEGER,
|
|
boxServicesPowSupplyItemState
|
|
INTEGER
|
|
}
|
|
|
|
boxServicesPowerSuppUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Power Supply Table"
|
|
::= { boxServicesPowSuppliesEntry 4 }
|
|
|
|
boxServicesPowSupplyIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of power supply table entry"
|
|
::= { boxServicesPowSuppliesEntry 1 }
|
|
|
|
boxServicesPowSupplyItemType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of power supply"
|
|
::= { boxServicesPowSuppliesEntry 2 }
|
|
|
|
|
|
boxServicesPowSupplyItemState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notpresent(1),
|
|
operational(2),
|
|
failed(3),
|
|
powering(4),
|
|
nopower(5),
|
|
notpowering(6),
|
|
incompatible(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of power supply. nopower(5) - This state means the power supply is present but no AC is connected.
|
|
incompatible(7) - This state is possible on boards capable of pluggable Power supplies"
|
|
::= { boxServicesPowSuppliesEntry 3 }
|
|
|
|
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesTempSensors
|
|
|
|
|
|
boxServicesTempSensorsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesTempSensorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature sensor"
|
|
::= { boxServicesGroup 8 }
|
|
|
|
|
|
boxServicesTempSensorsEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesTempSensorsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Temperature Sensor Entry"
|
|
INDEX { boxServicesUnitIndex, boxServicesTempSensorIndex }
|
|
::= { boxServicesTempSensorsTable 1 }
|
|
|
|
BoxServicesTempSensorsEntry ::= SEQUENCE {
|
|
boxServicesUnitIndex
|
|
Unsigned32,
|
|
boxServicesTempSensorIndex
|
|
Unsigned32,
|
|
boxServicesTempSensorType
|
|
INTEGER,
|
|
boxServicesTempSensorState
|
|
BoxsTemperatureStatus,
|
|
boxServicesTempSensorTemperature
|
|
Integer32
|
|
}
|
|
|
|
boxServicesUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Temperature Sensor Table"
|
|
::= { boxServicesTempSensorsEntry 1 }
|
|
|
|
boxServicesTempSensorIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index of temperature sensor table entry"
|
|
::= { boxServicesTempSensorsEntry 2 }
|
|
|
|
|
|
boxServicesTempSensorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fixed(1),
|
|
removable(2),
|
|
fixedAC(3),
|
|
removableDC(4),
|
|
fixedDC(5),
|
|
removableAC(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of temperature sensor"
|
|
::= { boxServicesTempSensorsEntry 3 }
|
|
|
|
|
|
boxServicesTempSensorState OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The state of temperature sensor"
|
|
::= { boxServicesTempSensorsEntry 4 }
|
|
|
|
|
|
boxServicesTempSensorTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature value reported by sensor"
|
|
::= { boxServicesTempSensorsEntry 5 }
|
|
|
|
boxServicesTempUnitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BoxServicesTempUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature status table"
|
|
::= { boxServicesGroup 15 }
|
|
|
|
boxServicesTempUnitEntry OBJECT-TYPE
|
|
SYNTAX BoxServicesTempUnitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Box Services Temperature Unit Entry"
|
|
INDEX { boxServicesTempUnitIndex }
|
|
::= { boxServicesTempUnitTable 1 }
|
|
|
|
BoxServicesTempUnitEntry ::= SEQUENCE {
|
|
boxServicesTempUnitIndex
|
|
Unsigned32,
|
|
boxServicesTempUnitState
|
|
BoxsTemperatureStatus,
|
|
boxServicesTempUnitTemperature
|
|
Integer32
|
|
}
|
|
|
|
boxServicesTempUnitIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unit index for an entry in the Box Services Temperature Unit Table"
|
|
::= { boxServicesTempUnitEntry 1 }
|
|
|
|
boxServicesTempUnitState OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The temperature state of the unit"
|
|
::= { boxServicesTempUnitEntry 2 }
|
|
|
|
boxServicesTempUnitTemperature OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest temperature currently reported by any sensor on the unit"
|
|
::= { boxServicesTempUnitEntry 3 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServicesNotificationsGroup
|
|
--
|
|
-- This group provides notification definitions for the Box Services
|
|
-- feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxServicesNotificationsGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 2 }
|
|
|
|
--**************************************************************************************
|
|
-- boxServices notification definitions
|
|
|
|
boxsItemStateChangeEvent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
insertion(1),
|
|
removal(2),
|
|
becomeoperational(3),
|
|
failure(4),
|
|
losepower(5)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes states of the fan or power supply.
|
|
|
|
insertion - hot-pluggable fan or power supply was inserted
|
|
removal - hot-pluggable fan or power supply was removed
|
|
becomeoperational - fan or power supply became operational after failure state
|
|
failure - fan or power supply failure happened, i.e. it is not able to perform its functions
|
|
losepower - a power supply was operational, but the power to it has been disconnected or has failed"
|
|
::= { boxServicesNotificationsGroup 1 }
|
|
|
|
boxsTemperatureChangeEvent OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
abovethreshold(1),
|
|
belowthreshold(2),
|
|
withinnormalrange(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes change of the temperature.
|
|
To avoid flipping on boundary conditions, it is allowed to send the trap
|
|
taking into account some margin around thresholds.
|
|
|
|
abovethreshold - temperature increased and crossed upper threshold value
|
|
belowthreshold - temperature decreased and crossed lower threshold value
|
|
withinnormalrange - temperature returned to normal range (between threshold)"
|
|
::= { boxServicesNotificationsGroup 2 }
|
|
|
|
boxsTemperatureStatusCurrentEvent OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes the current status of a switch."
|
|
::= { boxServicesNotificationsGroup 3 }
|
|
|
|
boxsTemperatureStatusPreviousEvent OBJECT-TYPE
|
|
SYNTAX BoxsTemperatureStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This event describes the previous status of a switch."
|
|
::= { boxServicesNotificationsGroup 4 }
|
|
|
|
|
|
|
|
--**************************************************************************************
|
|
-- Traps
|
|
--**************************************************************************************
|
|
|
|
fastPathBoxServicesTraps OBJECT IDENTIFIER ::= { fastPathBoxServices 0 }
|
|
|
|
|
|
|
|
boxsFanStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesFansIndex,
|
|
boxsItemStateChangeEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when fan state change happens."
|
|
::= { fastPathBoxServicesTraps 1 }
|
|
|
|
boxsPowSupplyStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesPowSupplyIndex,
|
|
boxsItemStateChangeEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when power supply state change happens."
|
|
::= { fastPathBoxServicesTraps 2 }
|
|
|
|
|
|
boxsTemperatureChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesTempSensorIndex,
|
|
boxsTemperatureChangeEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Trap is sent when temperature is changing and crossing any of the thresholds"
|
|
::= { fastPathBoxServicesTraps 3 }
|
|
|
|
|
|
boxsThermalShutdown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesThermalShutdownSensor,
|
|
boxServicesThermalShutdownTemperature
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when thermal shutdown is initiated."
|
|
::= { fastPathBoxServicesTraps 4 }
|
|
|
|
|
|
boxsTemperatureStateChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
boxServicesTempUnitIndex,
|
|
boxsTemperatureStatusCurrentEvent,
|
|
boxsTemperatureStatusPreviousEvent
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap is sent when the system temperature crosses a threshold.
|
|
To avoid rapid flapping between states, a hysteresis may
|
|
be applied."
|
|
::= { fastPathBoxServicesTraps 5 }
|
|
|
|
--**************************************************************************************
|
|
-- Locator LED manage group
|
|
--
|
|
-- This group provides manage definitions for the Locator LED feature.
|
|
--
|
|
--**************************************************************************************
|
|
|
|
boxsLocatorLedConfigGroup OBJECT IDENTIFIER ::= { fastPathBoxServices 4 }
|
|
|
|
boxsLocatorLedUnit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spesifies unit number where Locator LED should blink on.
|
|
This is write-only value. It always returns '0' on request
|
|
if the Locator Led feature is supported."
|
|
::= { boxsLocatorLedConfigGroup 1 }
|
|
|
|
boxsLocatorLedTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates time period in seconds for Locator LED blinking.
|
|
The range is from 20 to 3600 seconds.
|
|
The dafault value is 20 seconds.
|
|
This is write-only value. It always returns '0' on request
|
|
if the Locator Led feature is supported."
|
|
DEFVAL { 20 }
|
|
::= { boxsLocatorLedConfigGroup 2 }
|
|
|
|
boxsLocatorLedEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Starts the Locator LED blinking.
|
|
If boxsLocatorLedUnit has not been set current(manager) unit number will be used.
|
|
If boxsLocatorLedTime has not been set default value(20 seconds) will be used.
|
|
This is write-only value. It always returns '0' on request
|
|
if the Locator Led feature is supported."
|
|
::= { boxsLocatorLedConfigGroup 3 }
|
|
|
|
END
|