- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
619 lines
18 KiB
Text
619 lines
18 KiB
Text
|
|
-- File Name : EquipmentCommon_MIB.mib
|
|
-- Version : 1.01.00
|
|
-- Date : May 1, 2015
|
|
-- Author : DragonWave Inc.
|
|
|
|
EQUIPMENT-COMMON-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE, OBJECT-TYPE,
|
|
Counter64, IpAddress, Integer32, TimeTicks, Counter32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, DisplayString, DateAndTime,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
equipmentCommon
|
|
FROM DWI-HARMONY-PRIVATE-MIB;
|
|
|
|
-- Not supported : Opaque
|
|
-- [RFC2578]
|
|
-- [RFC2579]
|
|
--
|
|
-- Module Identity
|
|
--
|
|
|
|
equipmentCommonMib MODULE-IDENTITY
|
|
LAST-UPDATED "200901210000Z"
|
|
ORGANIZATION
|
|
"DragonWave Inc."
|
|
CONTACT-INFO
|
|
""
|
|
DESCRIPTION
|
|
"This MIB Module defines a notification log mechanism and a current alarm list."
|
|
|
|
REVISION "200901210000Z"
|
|
DESCRIPTION
|
|
"Initial Revision"
|
|
|
|
REVISION "201501051615Z"
|
|
DESCRIPTION
|
|
"Corrected EquipmentAlarmActiveTable index order."
|
|
::= { equipmentCommon 100 }
|
|
|
|
|
|
--
|
|
-- History of MIB Changes
|
|
--
|
|
--
|
|
--
|
|
-- Textual conventions
|
|
--
|
|
|
|
EnableType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enabled/Disabled"
|
|
SYNTAX INTEGER {
|
|
disabled (0),
|
|
enabled (1)
|
|
}
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
equipmentCommonObjects OBJECT IDENTIFIER ::= { equipmentCommon 1 }
|
|
equipmentConfigLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 1 }
|
|
equipmentLog OBJECT IDENTIFIER ::= { equipmentCommonObjects 2 }
|
|
equipmentAlarmList OBJECT IDENTIFIER ::= { equipmentCommonObjects 3 }
|
|
equipmentSnmpTrap OBJECT IDENTIFIER ::= { equipmentCommonObjects 4 }
|
|
equipmentPseudoEventsObjects OBJECT IDENTIFIER ::= { equipmentCommon 2 }
|
|
equipmentMirrorObjects OBJECT IDENTIFIER ::= { equipmentCommon 3 }
|
|
|
|
--
|
|
-- Object definitions: configuration section
|
|
--
|
|
|
|
equipmentEventLogEntryLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of notification entries that may be held
|
|
in EventLogTable."
|
|
DEFVAL { 4096 }
|
|
::= { equipmentConfigLog 1 }
|
|
|
|
--
|
|
-- Object definitions: event log section
|
|
--
|
|
|
|
equipmentEventLogLastEntry OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of equipmentEventLogIndex at the time of the last
|
|
creation of an entry in the equipmentEventLogTable."
|
|
::= { equipmentLog 1 }
|
|
|
|
--
|
|
-- Event Notification Log Table (inspired by RFC 3014)
|
|
--
|
|
|
|
equipmentEventLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EquipmentEventLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of Notification log entries."
|
|
::= { equipmentLog 2 }
|
|
|
|
equipmentEventLogEntry OBJECT-TYPE
|
|
SYNTAX EquipmentEventLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Notification log entry. Entries appear in this table
|
|
when Notifications occur. They are removed to make way
|
|
for new entries due to lack of resources or the values of
|
|
equipmentEventLogEntryLimit.If adding an entry would exceed
|
|
equipmentEventLogEntryLimit the oldest entry in that log SHOULD
|
|
be removed to make room for the new one."
|
|
INDEX { equipmentEventLogIndex }
|
|
::= { equipmentEventLogTable 1 }
|
|
|
|
EquipmentEventLogEntry ::= SEQUENCE {
|
|
equipmentEventLogIndex
|
|
Unsigned32,
|
|
equipmentEventLogTime
|
|
TimeStamp,
|
|
equipmentEventLogDateAndTime
|
|
DateAndTime,
|
|
equipmentEventLogNotificationID
|
|
OBJECT IDENTIFIER,
|
|
equipmentEventLogVariables
|
|
Unsigned32
|
|
}
|
|
|
|
equipmentEventLogIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A monotonically increasing integer for the sole purpose of
|
|
indexing entries within the log. When it reaches the
|
|
maximum value,the agent wraps the value back to 1.
|
|
This number should correspond to the number of notifications
|
|
sent by the agent."
|
|
::= { equipmentEventLogEntry 1 }
|
|
|
|
equipmentEventLogTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the entry was placed in the log."
|
|
::= { equipmentEventLogEntry 2 }
|
|
|
|
equipmentEventLogDateAndTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local date and time when the entry was logged, useful when browsing the MIB."
|
|
::= { equipmentEventLogEntry 3 }
|
|
|
|
equipmentEventLogNotificationID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NOTIFICATION-TYPE object identifier of the Notification that
|
|
occurred."
|
|
::= { equipmentEventLogEntry 4 }
|
|
|
|
equipmentEventLogVariables OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of variables in equipmentEventLogVariableTable for this
|
|
logged notification."
|
|
::= { equipmentEventLogEntry 5 }
|
|
|
|
--
|
|
-- Event Log variable Table
|
|
--
|
|
|
|
equipmentEventLogVariableTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EquipmentEventLogVariableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of variables to go with Notification log entries."
|
|
::= { equipmentLog 3 }
|
|
|
|
equipmentEventLogVariableEntry OBJECT-TYPE
|
|
SYNTAX EquipmentEventLogVariableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Notification log entry variable.
|
|
|
|
Entries appear in this table when there are variables in
|
|
the varbind list of a Notification in equipmentEventLogTable."
|
|
INDEX { equipmentEventLogIndex,
|
|
equipmentEventLogVariableIndex }
|
|
::= { equipmentEventLogVariableTable 1 }
|
|
|
|
EquipmentEventLogVariableEntry ::= SEQUENCE {
|
|
equipmentEventLogVariableIndex
|
|
Unsigned32,
|
|
equipmentEventLogVariableID
|
|
OBJECT IDENTIFIER,
|
|
equipmentEventLogVariableValueType
|
|
INTEGER,
|
|
equipmentEventLogVariableCounter32Val
|
|
Counter32,
|
|
equipmentEventLogVariableUnsigned32Val
|
|
Unsigned32,
|
|
equipmentEventLogVariableTimeTicksVal
|
|
TimeTicks,
|
|
equipmentEventLogVariableInteger32Val
|
|
Integer32,
|
|
equipmentEventLogVariableOctetStringVal
|
|
OCTET STRING,
|
|
equipmentEventLogVariableIpAddressVal
|
|
IpAddress,
|
|
equipmentEventLogVariableOidVal
|
|
OBJECT IDENTIFIER,
|
|
equipmentEventLogVariableCounter64Val
|
|
Counter64
|
|
}
|
|
|
|
equipmentEventLogVariableIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A monotonically increasing integer, starting at 1 for a given
|
|
equipmentEventLogIndex, for indexing variables within the logged
|
|
Event Notification."
|
|
::= { equipmentEventLogVariableEntry 1 }
|
|
|
|
equipmentEventLogVariableID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The variable's object identifier."
|
|
::= { equipmentEventLogVariableEntry 2 }
|
|
|
|
equipmentEventLogVariableValueType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
counter32 (1),
|
|
unsigned32 (2),
|
|
timeTicks (3),
|
|
integer32 (4),
|
|
ipAddress (5),
|
|
octetString (6),
|
|
objectId (7),
|
|
counter64 (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of the value. One and only one of the value
|
|
objects that follow must be instantiated, based on this type."
|
|
::= { equipmentEventLogVariableEntry 3 }
|
|
|
|
-- Not supported: opaque(9)
|
|
|
|
equipmentEventLogVariableCounter32Val OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'counter32'."
|
|
::= { equipmentEventLogVariableEntry 4 }
|
|
|
|
equipmentEventLogVariableUnsigned32Val OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'unsigned32'."
|
|
::= { equipmentEventLogVariableEntry 5 }
|
|
|
|
equipmentEventLogVariableTimeTicksVal OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'timeTicks'."
|
|
::= { equipmentEventLogVariableEntry 6 }
|
|
|
|
equipmentEventLogVariableInteger32Val OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'integer32'."
|
|
::= { equipmentEventLogVariableEntry 7 }
|
|
|
|
equipmentEventLogVariableOctetStringVal OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'octetString'."
|
|
::= { equipmentEventLogVariableEntry 8 }
|
|
|
|
equipmentEventLogVariableIpAddressVal OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'ipAddress'.
|
|
Although this seems to be unfriendly for IPv6, we
|
|
have to recognize that there are a number of older
|
|
MIBs that do contain an IPv4 format address, known
|
|
as IpAddress.
|
|
|
|
IPv6 addresses are represented using TAddress or
|
|
InetAddress, and so the underlying datatype is
|
|
OCTET STRING, and their value would be stored in
|
|
the equipmentEventLogVariableOctetStringVal column."
|
|
::= { equipmentEventLogVariableEntry 9 }
|
|
|
|
equipmentEventLogVariableOidVal OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'objectId'."
|
|
::= { equipmentEventLogVariableEntry 10 }
|
|
|
|
equipmentEventLogVariableCounter64Val OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value when equipmentEventLogVariableValueType is 'counter64'."
|
|
::= { equipmentEventLogVariableEntry 11 }
|
|
|
|
--
|
|
-- Opaque type not supported
|
|
--
|
|
-- equipmentEventLogVariableOpaqueVal OBJECT-TYPE
|
|
-- SYNTAX Opaque
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The value when equipmentEventLogVariableValueType is 'opaque'."
|
|
-- ::= { equipmentEventLogVariableEntry 12 }
|
|
--
|
|
-- Object definitions: active alarm list section
|
|
--
|
|
--
|
|
-- Active Alarm Table
|
|
--
|
|
|
|
equipmentAlarmActiveLastChanged OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time of the last
|
|
creation or deletion of an entry in the equipmentAlarmActiveTable.
|
|
Useful in case of polling (no traps mechanism used).
|
|
If the number of entries has been unchanged since the
|
|
last re-initialization, then this object contains a zero value."
|
|
::= { equipmentAlarmList 1 }
|
|
|
|
equipmentAlarmActiveRowCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of active alarms row in the table."
|
|
::= { equipmentAlarmList 2 }
|
|
|
|
equipmentAlarmActiveTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EquipmentAlarmActiveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A table of Active Alarms entries."
|
|
::= { equipmentAlarmList 3 }
|
|
|
|
equipmentAlarmActiveEntry OBJECT-TYPE
|
|
SYNTAX EquipmentAlarmActiveEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entries appear in this table when alarms are raised. They
|
|
are removed when the alarm is cleared."
|
|
INDEX { equipmentAlarmActiveIndex,
|
|
equipmentAlarmActiveTime }
|
|
::= { equipmentAlarmActiveTable 1 }
|
|
|
|
EquipmentAlarmActiveEntry ::= SEQUENCE {
|
|
equipmentAlarmActiveIndex
|
|
Unsigned32,
|
|
equipmentAlarmActiveTime
|
|
TimeStamp,
|
|
equipmentAlarmActiveDateAndTime
|
|
DateAndTime,
|
|
equipmentAlarmActiveName
|
|
DisplayString,
|
|
equipmentAlarmActiveID
|
|
Integer32,
|
|
equipmentAlarmActiveInstance
|
|
Unsigned32,
|
|
equipmentAlarmActiveTrapOID
|
|
OBJECT IDENTIFIER,
|
|
equipmentAlarmActiveSeverity
|
|
INTEGER,
|
|
equipmentAlarmActiveConditionId
|
|
DisplayString
|
|
}
|
|
|
|
equipmentAlarmActiveIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A strictly monotonically increasing integer which
|
|
acts as the index of entries within the named alarm
|
|
list. It wraps back to 1 after it reaches its
|
|
maximum value."
|
|
::= { equipmentAlarmActiveEntry 1 }
|
|
|
|
equipmentAlarmActiveTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the entry was placed in the list.
|
|
This object facilitates retrieving all instances of
|
|
alarms that have been raised or have changed state
|
|
since a given point in time."
|
|
::= { equipmentAlarmActiveEntry 2 }
|
|
|
|
equipmentAlarmActiveDateAndTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local date and time when the error occurred.
|
|
|
|
This object facilitates retrieving all instances of
|
|
alarms that have been raised or have changed state
|
|
since a given point in time.
|
|
|
|
Implementations MUST include the offset from UTC,
|
|
if available. Implementation in environments in which
|
|
the UTC offset is not available is NOT RECOMMENDED."
|
|
::= { equipmentAlarmActiveEntry 3 }
|
|
|
|
equipmentAlarmActiveName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the active alarm name."
|
|
::= { equipmentAlarmActiveEntry 4 }
|
|
|
|
equipmentAlarmActiveID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the active alarm ID which is the index to the alarm configuration table defined in product specific MIB."
|
|
::= { equipmentAlarmActiveEntry 5 }
|
|
|
|
equipmentAlarmActiveInstance OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { equipmentAlarmActiveEntry 6 }
|
|
|
|
equipmentAlarmActiveTrapOID OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MIB object identifier of the alarm (contained in an Alarm Notification
|
|
type object) that is occurring."
|
|
::= { equipmentAlarmActiveEntry 7 }
|
|
|
|
equipmentAlarmActiveSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
warning (1),
|
|
minor (2),
|
|
major (3),
|
|
critical (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the active alarm severity."
|
|
::= { equipmentAlarmActiveEntry 8 }
|
|
|
|
equipmentAlarmActiveConditionId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { equipmentAlarmActiveEntry 9 }
|
|
|
|
--
|
|
-- Opaque type not supported
|
|
--
|
|
-- equipmentAlarmActiveSourceOpaqueVal OBJECT-TYPE
|
|
-- SYNTAX Opaque
|
|
-- MAX-ACCESS read-only
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "The value when value type is 'opaque'.It is coded as follows:
|
|
-- code: OCTET STRING(SIZE(1)), fixed to 1 (structure identifier);
|
|
-- type: INTEGER, see equipmentEventLogVariableValueType values;
|
|
-- value: ASN.1 basic encoding rule"
|
|
-- ::= { equipmentAlarmActiveEntry 5 }
|
|
--
|
|
-- Object definitions: trap counter and timestamp
|
|
--
|
|
|
|
equipmentOutTrapsCounter OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The counter of the output traps.
|
|
It increases by one every time a new trap is sent to all the managers configured
|
|
in the relevant table. In this way its value is the number of notification events
|
|
occurred since the last agent reset and every manager that reads this value can understand
|
|
whether some event has been lost or not.
|
|
(Note that in general this counter differs from the RFC1213 snmpOutTraps, that counts the
|
|
number of Trap PDUs sent). When the logging mechanism is enabled, it corresponds to the index in the eventlog table"
|
|
::= { equipmentSnmpTrap 1 }
|
|
|
|
equipmentLastOutTrapTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the last trap was sent."
|
|
::= { equipmentSnmpTrap 2 }
|
|
|
|
equipmentTrapInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A string representing additional info that can be used as the varbind in trap. "
|
|
::= { equipmentSnmpTrap 3 }
|
|
|
|
--
|
|
-- Object definitions: pseudo-events support
|
|
--
|
|
|
|
equipmentConfChangeOid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The OID of the last node changed. It is sent to the managers in order to
|
|
notify a configuration change."
|
|
::= { equipmentPseudoEventsObjects 1 }
|
|
|
|
equipmentConfChangeMode OBJECT-TYPE
|
|
SYNTAX EnableType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable/Disable of sending ConfChange Trap.
|
|
STORAGE: permanent."
|
|
DEFVAL { enabled }
|
|
::= { equipmentPseudoEventsObjects 2 }
|
|
|
|
equipmentConfChangeNotification NOTIFICATION-TYPE
|
|
OBJECTS { equipmentConfChangeOid,
|
|
equipmentOutTrapsCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notification of configuration change."
|
|
::= { equipmentPseudoEventsObjects 3 }
|
|
|
|
--
|
|
-- Object definitions: mirror-traps support
|
|
--
|
|
|
|
equipmentMirrorFlag OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fixed to 1=mirror trap"
|
|
::= { equipmentMirrorObjects 1 }
|
|
|
|
equipmentMirrorColdStart NOTIFICATION-TYPE
|
|
OBJECTS { equipmentMirrorFlag,
|
|
equipmentOutTrapsCounter }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A coldStart trap signifies that the SNMP entity,
|
|
supporting a notification originator application, is
|
|
reinitializing itself and that its configuration may
|
|
have been altered."
|
|
::= { equipmentMirrorObjects 2 }
|
|
END
|
|
|
|
|