- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
1346 lines
39 KiB
Text
1346 lines
39 KiB
Text
--
|
|
-- sle-mpls-tp-oam-mib.mib
|
|
-- MIB generated by MG-SOFT Visual MIB Builder Version 6.0 Build 88
|
|
-- Friday, February 05, 2016 at 11:01:54
|
|
--
|
|
|
|
SLE-MPLS-TP-OAM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
sleMgmt
|
|
FROM DASAN-SMI
|
|
ifGeneralInformationGroup, ifCounterDiscontinuityGroup
|
|
FROM IF-MIB
|
|
mplsStdMIB
|
|
FROM MPLS-TC-STD-MIB
|
|
SleControlStatusType, SleControlRequestResultType
|
|
FROM SLE-TC-MIB
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
zeroDotZero, TimeTicks, Unsigned32, Gauge32, OBJECT-TYPE,
|
|
MODULE-IDENTITY, OBJECT-IDENTITY
|
|
FROM SNMPv2-SMI;
|
|
|
|
|
|
sleMplsTpOam MODULE-IDENTITY
|
|
LAST-UPDATED "201510070000Z" -- October 07, 2015 at 00:00 GMT
|
|
ORGANIZATION
|
|
" DASAN Networks"
|
|
CONTACT-INFO
|
|
"Gyerok Kwon
|
|
Dasan Networks
|
|
Email: grkwon@dasannetworks.com
|
|
|
|
Kantharaj B M
|
|
Dasan Networks
|
|
Email: kanth@dasannetworks.com
|
|
|
|
DongChel Shin (Chris)
|
|
Dasan Networks
|
|
Email: dchshin@dasannetworks.com
|
|
|
|
Comments about this document should be emailed
|
|
directly to the Dasan support email ID at
|
|
support@dasannetworks.com."
|
|
DESCRIPTION
|
|
"sleMpls"
|
|
REVISION "201301080000Z" -- January 08, 2013 at 00:00 GMT
|
|
DESCRIPTION
|
|
" "
|
|
::= { sleMpls 17 }
|
|
|
|
|
|
|
|
|
|
--
|
|
-- Node definitions
|
|
--
|
|
|
|
sleMpls OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLE MPLS."
|
|
::= { sleMgmt 16 }
|
|
|
|
|
|
sleMplsTpOamMeg OBJECT IDENTIFIER ::= { sleMplsTpOam 1 }
|
|
|
|
|
|
sleMplsTpOamMegInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpOamMegInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains information about the Maintenance
|
|
Entity Groups (MEG).
|
|
|
|
MEG as mentioned in MPLS-TP OAM framework defines a set
|
|
of one or more maintenance entities (ME).
|
|
Maintenance Entities define a relationship between any
|
|
two points of a transport path in an OAM domain to which
|
|
maintenance and monitoring operations apply."
|
|
::= { sleMplsTpOamMeg 1 }
|
|
|
|
|
|
sleMplsTpOamMegInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpOamMegInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table represents MPLS-TP MEG.
|
|
An entry can be created by a network administrator
|
|
or by an SNMP agent as instructed by an MPLS-TP OAM
|
|
Framework.
|
|
|
|
When a new entry is created with
|
|
sleMplsTpOamMegOperatorType set to ipCompatible (1),
|
|
then as per [RFC6370] (MEG_ID for LSP is LSP_ID and
|
|
MEG_ID for PW is PW_Path_ID), MEP_ID can be
|
|
automatically formed.
|
|
|
|
For co-routed bidirectional LSP, MEG_ID is
|
|
A1-{Global_ID::Node_ID::Tunnel_Num}::Z9-{Global_ID::
|
|
Node_ID::Tunnel_Num}::LSP_Num.
|
|
|
|
For associated bidirectional LSP, MEG_ID is A1-
|
|
{Global_ID::Node_ID::Tunnel_Num::LSP_Num}:: Z9-
|
|
{Global_ID::Node_ID::Tunnel_Num::LSP_Num}
|
|
|
|
For LSP, MEP_ID is formed using,
|
|
Global_ID::Node_ID::Tunnel_Num::LSP_Num
|
|
|
|
For PW, MEG_ID is formed using AGI::A1-
|
|
{Global_ID::Node_ID::AC_ID}:: Z9-
|
|
{Global_ID::Node_ID::AC_ID}.
|
|
|
|
For PW, MEP_ID is formed using
|
|
AGI::Global_ID::Node_ID::AC_ID
|
|
|
|
MEP_ID is retrieved from the sleMplsTpOamMegServicePointer
|
|
object based on the sleMplsTpOamMegServiceType value.
|
|
ICC MEG_ID for LSP and PW is formed using the objects
|
|
sleMplsTpOamMegIdIcc and sleMplsTpOamMegIdUmc.
|
|
|
|
MEP_ID can be formed using MEG_ID::MEP_Index."
|
|
REFERENCE
|
|
"1. RFC 5860, Requirements for OAM in MPLS Transport
|
|
Networks, May 2010.
|
|
2. RFC 6371, Operations, Administration, and Maintenance
|
|
Framework for MPLS-Based Transport Networks,
|
|
September 2011.
|
|
3. RFC 6370, MPLS Transport Profile (MPLS-TP) Identifiers.
|
|
4. MPLS-TP Identifiers Following ITU-T Conventions
|
|
[TP-ITUIDS]."
|
|
INDEX { sleMplsTpOamMegInfoIndex }
|
|
::= { sleMplsTpOamMegInfoTable 1 }
|
|
|
|
|
|
SleMplsTpOamMegInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpOamMegInfoIndex
|
|
Unsigned32,
|
|
sleMplsTpOamMegInfoName
|
|
OCTET STRING,
|
|
sleMplsTpOamMegInfoOperatorType
|
|
INTEGER,
|
|
sleMplsTpOamMegInfoServiceType
|
|
INTEGER,
|
|
sleMplsTpOamMegInfoMegLevel
|
|
INTEGER,
|
|
sleMplsTpOamMegInfoOperStatus
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpOamMegInfoIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index for the conceptual row identifying a MEG within
|
|
|
|
this MEG table."
|
|
::= { sleMplsTpOamMegInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpOamMegInfoName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..48))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each Maintenance Entity Group has unique name amongst
|
|
all those used or available to a service provider or
|
|
operator. It facilitates easy identification of
|
|
administrative responsibility for each MEG.
|
|
IETF : MEG Name Max. 48 characters long
|
|
ITUT : MEG Name Max 5 characters(Excluding /)."
|
|
::= { sleMplsTpOamMegInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpOamMegInfoOperatorType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to set the IETF or ITUT. "
|
|
REFERENCE
|
|
"1. RFC 6370, MPLS Transport Profile (MPLS-TP)
|
|
Identifiers.
|
|
2. MPLS-TP Identifiers Following ITU-T Conventions
|
|
[TP-ITUIDS]."
|
|
::= { sleMplsTpOamMegInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpOamMegInfoServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tunnel(1),
|
|
vc(2),
|
|
datalink(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the service type for which the MEG is created.
|
|
If the service type indicates lsp, the service pointer
|
|
in sleMplsOamMe points to the TE tunnel table entry.
|
|
|
|
If the value is pseudowire service type, the service
|
|
pointer in sleMplsOamMe points to the pseudowire
|
|
table entry.
|
|
|
|
If the value is section service type, the service
|
|
pointer in sleMplsOamMe points to a section entry."
|
|
::= { sleMplsTpOamMegInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpOamMegInfoMegLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to for level
|
|
for ITUT. When a row in this table is in active object cannot
|
|
be changed."
|
|
::= { sleMplsTpOamMegInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpOamMegInfoOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the operational status of the
|
|
Maintenance Entity Group (MEG). This object is used to
|
|
send the notification to the SNMP manager about the MEG.
|
|
|
|
The value up (1) indicates that the MEG and its monitored
|
|
path are operationally up. The value down (2) indicates
|
|
that the MEG is operationally down.
|
|
|
|
When the value of mplsOamIdMegOperStatus is up(1), all
|
|
the bits of mplsOamIdMegSubOperStatus must be cleared.
|
|
When the value of mplsOamIdMegOperStatus is down(2),
|
|
at least one bit of mplsOamIdMegSubOperStatus must be
|
|
set."
|
|
::= { sleMplsTpOamMegInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpOamMegControl OBJECT IDENTIFIER ::= { sleMplsTpOamMeg 2 }
|
|
|
|
|
|
sleMplsTpOamMegControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createsleMplsTpOamMegControlEntry(1),
|
|
deletesleMplsTpOamMegControlEntry(2),
|
|
setsleMplsTpOamMegControlServiceType(3),
|
|
setsleMplsTpOamMegControlLevel(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the configuration commands, and user can configure
|
|
functions via setting this entry as proper value."
|
|
::= { sleMplsTpOamMegControl 1 }
|
|
|
|
|
|
sleMplsTpOamMegControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"status of user command. User have to check this value as .busy.
|
|
or .idle. before do setRequest."
|
|
::= { sleMplsTpOamMegControl 2 }
|
|
|
|
|
|
sleMplsTpOamMegControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the wait-time until setRequest end. In case of short-time command,
|
|
this value is 0"
|
|
::= { sleMplsTpOamMegControl 3 }
|
|
|
|
|
|
sleMplsTpOamMegControlTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the time stamp of the last command. (don.t care)"
|
|
::= { sleMplsTpOamMegControl 4 }
|
|
|
|
|
|
sleMplsTpOamMegControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last command."
|
|
::= { sleMplsTpOamMegControl 5 }
|
|
|
|
|
|
sleMplsTpOamMegControlName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..48))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each Maintenance Entity Group has unique name amongst
|
|
all those used or available to a service provider or
|
|
operator. It facilitates easy identification of
|
|
administrative responsibility for each MEG."
|
|
::= { sleMplsTpOamMegControl 6 }
|
|
|
|
|
|
sleMplsTpOamMegControlOperatorType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ietf(1),
|
|
itut(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the operator type for MEG. Conceptual rows
|
|
having 'iccBased' as operator type, should have valid
|
|
values for the objects sleMplsTpOamMegControlIdIcc and
|
|
sleMplsTpOamMegControlIdUmc while making the row status active."
|
|
REFERENCE
|
|
"1. RFC 6370, MPLS Transport Profile (MPLS-TP)
|
|
Identifiers.
|
|
2. MPLS-TP Identifiers Following ITU-T Conventions
|
|
[TP-ITUIDS]."
|
|
::= { sleMplsTpOamMegControl 7 }
|
|
|
|
|
|
sleMplsTpOamMegControlServiceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
tunnel(1),
|
|
vc(2),
|
|
datalink(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the service type for which the MEG is created.
|
|
If the service type indicates lsp, the service pointer
|
|
in sleMplsOamMe points to the TE tunnel table entry.
|
|
|
|
If the value is pseudowire service type, the service
|
|
pointer in sleMplsOamMe points to the pseudowire
|
|
table entry.
|
|
|
|
If the value is section service type, the service
|
|
pointer in sleMplsOamMe points to a section entry."
|
|
::= { sleMplsTpOamMegControl 8 }
|
|
|
|
|
|
sleMplsTpOamMegControlLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to for level
|
|
for ITUT. When a row in this table is in active object cannot
|
|
be changed."
|
|
::= { sleMplsTpOamMegControl 9 }
|
|
|
|
|
|
sleMplsTpOamMaintananceEntity OBJECT IDENTIFIER ::= { sleMplsTpOam 2 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpOamMaintanceEntityInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains MPLS-TP maintenance entity
|
|
information.
|
|
|
|
ME is some portion of a transport path that requires
|
|
management bounded by two points (called MEPs), and the
|
|
relationship between those points to which maintenance
|
|
and monitoring operations apply.
|
|
|
|
This table is generic enough to handle MEPs and MIPs
|
|
information within a MEG."
|
|
::= { sleMplsTpOamMaintananceEntity 1 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpOamMaintanceEntityInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table represents MPLS-TP maintenance
|
|
entity. This entry represents the ME if the source and
|
|
sink MEPs are defined.
|
|
|
|
A ME is a p2p entity. One ME has two such MEPs.
|
|
A MEG is a group of one or more MEs. One MEG can have
|
|
two or more MEPs.
|
|
|
|
For P2P LSP, one MEG has one ME and this ME is associated
|
|
two MEPs (source and sink MEPs) within a MEG.
|
|
Each sleMplsOamMeIndex value denotes the ME within a MEG.
|
|
|
|
In case of unidirectional point-to-point transport paths,
|
|
a single unidirectional Maintenance Entity is defined to
|
|
monitor it and sleMplsOamMeServicePointer points to
|
|
unidirectional point-to-point path.
|
|
|
|
In case of associated bidirectional point-to-point
|
|
transport paths, two independent unidirectional
|
|
Maintenance Entities are defined to independently monitor
|
|
each direction and each sleMplsOamMeServicePointer MIB
|
|
object points to unique unidirectional transport path.
|
|
This has implications for transactions that terminate at
|
|
or query a MIP, as a return path from MIP to source MEP
|
|
does not necessarily exist within the MEG.
|
|
|
|
In case of co-routed bidirectional point-to-point
|
|
transport paths, a single bidirectional Maintenance Entity
|
|
|
|
|
|
|
|
is defined to monitor both directions congruently and
|
|
sleMplsOamMeServicePointer MIB object points to co-routed
|
|
bidirectional point-to-point transport path.
|
|
|
|
In case of unidirectional point-to-multipoint transport
|
|
paths, a single unidirectional Maintenance entity for each
|
|
leaf is defined to monitor the transport path from the
|
|
root to that leaf and each leaf has different transport
|
|
path information in sleMplsOamMeServicePointer MIB object."
|
|
INDEX { sleMplsTpOamMaintanceEntityInfoMeIndex, sleMplsTpOamMaintanceEntityInfoMpIndex }
|
|
::= { sleMplsTpOamMaintanceEntityInfoTable 1 }
|
|
|
|
|
|
SleMplsTpOamMaintanceEntityInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpOamMaintanceEntityInfoMeIndex
|
|
Unsigned32,
|
|
sleMplsTpOamMaintanceEntityInfoMpIndex
|
|
Unsigned32,
|
|
sleMplsOamMaintenanceEntityInfoMeName
|
|
SnmpAdminString,
|
|
sleMplsTpOamMaintanceEntityInfoMpType
|
|
INTEGER,
|
|
sleMplsOamMaintenanceEntityInfoServiceTunnelName
|
|
OCTET STRING,
|
|
sleMplsOamMaintenanceEntityInfoServiceVcId
|
|
Unsigned32,
|
|
sleMplsOamMaintenanceEntityInfoServiceDatalink
|
|
OCTET STRING,
|
|
sleMplsTpOamMaintanceEntityInfoCcInterval
|
|
Unsigned32,
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMpId
|
|
Unsigned32,
|
|
sleMplsTpOamMaintanceEntityInfoRemoteCc
|
|
OCTET STRING,
|
|
sleMplsTpOamMaintanceEntityInfoRemoteIcc
|
|
OCTET STRING,
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMeg
|
|
OCTET STRING,
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMpdirection
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpOamMaintanceEntityInfoMeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoMpIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point index, used to create
|
|
multiple MEPs in a node of single ME. The value of this
|
|
object can be MEP index or MIP index. Managers should
|
|
obtain new values for row creation in this table by reading
|
|
mplsOamIdMeMpIndexNext."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 2 }
|
|
|
|
|
|
sleMplsOamMaintenanceEntityInfoMeName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (1..48))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object denotes the ME name, each
|
|
Maintenance Entity has unique name within MEG."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoMpType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
mep(1),
|
|
mip(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point type within the MEG.
|
|
The object should have the value mep (1), only in the
|
|
Ingress or Egress nodes of the transport path.
|
|
The object can have the value mip (2),
|
|
in the intermediate nodes and possibly in the end nodes
|
|
of the transport path."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 4 }
|
|
|
|
|
|
sleMplsOamMaintenanceEntityInfoServiceTunnelName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents a pointer to the MPLS-TP
|
|
transport path. This value may point at an entry in the
|
|
sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
|
|
as lsp (1) or at an entry in the pwEntry if
|
|
sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
|
|
|
|
Note: This service pointer object, is placed in ME table
|
|
instead of MEG table, since it will be useful in case of
|
|
point-to-multipoint, where each ME will point to different
|
|
branches of a P2MP tree."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 5 }
|
|
|
|
|
|
sleMplsOamMaintenanceEntityInfoServiceVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents a pointer to the MPLS-TP
|
|
transport path. This value may point at an entry in the
|
|
sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
|
|
as lsp (1) or at an entry in the pwEntry if
|
|
sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
|
|
|
|
Note: This service pointer object, is placed in ME table
|
|
instead of MEG table, since it will be useful in case of
|
|
point-to-multipoint, where each ME will point to different
|
|
branches of a P2MP tree."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 6 }
|
|
|
|
|
|
sleMplsOamMaintenanceEntityInfoServiceDatalink OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents a pointer to the MPLS-TP
|
|
transport path. This value may point at an entry in the
|
|
sleMplsTunnelEntry ifsleMplsOamMaintenanceEntitygServiceType is configured
|
|
as lsp (1) or at an entry in the pwEntry if
|
|
sleMplsOamMaintenanceEntitygServiceType is configured as pseudowire (2).
|
|
|
|
Note: This service pointer object, is placed in ME table
|
|
instead of MEG table, since it will be useful in case of
|
|
point-to-multipoint, where each ME will point to different
|
|
branches of a P2MP tree."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoCcInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to keep the continuty check interval
|
|
for ITUT. When a row in this table is in active object cannot
|
|
be changed."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 8 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMpId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used for setting the remote mep id "
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 9 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoRemoteCc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..2))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global uniqueness is assured by concatenating the ICC
|
|
with a Country Code (CC). The Country Code (alpha-2)
|
|
is a string of two alphabetic characters represented
|
|
with upper case letters (i.e., A-Z).
|
|
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 3."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 10 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoRemoteIcc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique code assigned to Network Operator or Service
|
|
Provider maintained by ITU-T. The ITU Carrier Code
|
|
used to form MEGID.
|
|
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 3.1."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 11 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMeg OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique code assigned by Network Operator or Service
|
|
Provider and is appended to mplsOamIdMegIdIcc to form
|
|
the MEGID.
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 7.1."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 12 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityInfoRemoteMpdirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
forward(1),
|
|
reverse(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point type within the MEG.
|
|
This object is used to display the forward and reverse remote mep of
|
|
Transist router ."
|
|
::= { sleMplsTpOamMaintanceEntityInfoEntry 13 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControl OBJECT IDENTIFIER ::= { sleMplsTpOamMaintananceEntity 2 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
createsleMplsTpOamMaintanceEntityControlEntry(1),
|
|
deletesleMplsTpOamMaintanceEntityControlEntry(2),
|
|
setsleMplsTpOamMaintanceEntityControlServiceValue(3),
|
|
setSleMplsTpOamMepControlCCInterval(4),
|
|
unsetSleMplsTpOamMepControlCCInterval(5),
|
|
setsleMplsTpOamMaintanceEntityControlRmepId(6),
|
|
unsetsleMplsTpOamMaintanceEntityControlRmepId(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the configuration commands, and user can configure functions
|
|
via setting this entry as proper value."
|
|
::= { sleMplsTpOamMaintanceEntityControl 1 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"status of user command. User have to check this value as
|
|
.busy. or .idle. before do setRequest."
|
|
::= { sleMplsTpOamMaintanceEntityControl 2 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the wait-time until setRequest end. In case of short-time
|
|
command, this value is 0"
|
|
::= { sleMplsTpOamMaintanceEntityControl 3 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the time stamp of the last command. (don.t care)"
|
|
::= { sleMplsTpOamMaintanceEntityControl 4 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last command."
|
|
::= { sleMplsTpOamMaintanceEntityControl 5 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlMegName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG."
|
|
::= { sleMplsTpOamMaintanceEntityControl 6 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlMeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (1..48))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object denotes the ME name, each
|
|
Maintenance Entity has unique name within MEG."
|
|
::= { sleMplsTpOamMaintanceEntityControl 7 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlMepId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEP ."
|
|
::= { sleMplsTpOamMaintanceEntityControl 8 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlMpType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
mep(1),
|
|
mip(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point type within the MEG.
|
|
|
|
The object should have the value mep (1), only in the
|
|
Ingress or Egress nodes of the transport path.
|
|
|
|
The object can have the value mip (2),
|
|
in the intermediate nodes and possibly in the end nodes
|
|
of the transport path."
|
|
::= { sleMplsTpOamMaintanceEntityControl 9 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlServiceValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable represents a pointer to the MPLS-TP
|
|
transport path. This value may point at an entry in the
|
|
sleMplsTunnelEntry if sleMplsOamMeControlgServiceType is configured
|
|
as lsp (1) or at an entry in the pwEntry if
|
|
sleMplsOamMeControlgServiceType is configured as pseudowire (2).
|
|
|
|
Note: This service pointer object, is placed in ME table
|
|
instead of MEG table, since it will be useful in case of
|
|
point-to-multipoint, where each ME will point to different
|
|
branches of a P2MP tree."
|
|
::= { sleMplsTpOamMaintanceEntityControl 10 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlCcInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to keep the continuty check interval
|
|
for ITUT. When a row in this table is in active object cannot
|
|
be changed."
|
|
::= { sleMplsTpOamMaintanceEntityControl 11 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlRemoteMpId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used for setting the remote mep id "
|
|
::= { sleMplsTpOamMaintanceEntityControl 12 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlRemoteCc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..2))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global uniqueness is assured by concatenating the ICC
|
|
with a Country Code (CC). The Country Code (alpha-2)
|
|
is a string of two alphabetic characters represented
|
|
with upper case letters (i.e., A-Z).
|
|
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 3."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityControl 13 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlRemoteIcc OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..6))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique code assigned to Network Operator or Service
|
|
Provider maintained by ITU-T. The ITU Carrier Code
|
|
used to form MEGID.
|
|
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 3.1."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityControl 14 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlRemoteMeg OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..7))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique code assigned by Network Operator or Service
|
|
Provider and is appended to mplsOamIdMegIdIcc to form
|
|
the MEGID.
|
|
This object MUST contain a non-null ICC value if
|
|
the MplsOamIdMegOperatorType value is iccBased(2),
|
|
otherwise a null ICC value with octet size 0
|
|
should be assigned."
|
|
REFERENCE
|
|
"RFC6923, MPLS Transport Profile (MPLS-TP) Identifiers
|
|
Following ITU-T Conventions. Section 7.1."
|
|
DEFVAL { "" }
|
|
::= { sleMplsTpOamMaintanceEntityControl 15 }
|
|
|
|
|
|
sleMplsTpOamMaintanceEntityControlRemoteMpDirection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fwd(1),
|
|
rev(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the direction of the MEP. This object
|
|
should be configured if sleMplsOamMeControlMpType is
|
|
configured as mep (1)."
|
|
::= { sleMplsTpOamMaintanceEntityControl 16 }
|
|
|
|
|
|
sleMplsTpOamFm OBJECT IDENTIFIER ::= { sleMplsTpOam 3 }
|
|
|
|
|
|
sleMplsTpOamFmInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SleMplsTpOamFmInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " "
|
|
::= { sleMplsTpOamFm 1 }
|
|
|
|
|
|
sleMplsTpOamFmInfoEntry OBJECT-TYPE
|
|
SYNTAX SleMplsTpOamFmInfoEntry
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in this table represents MPLS-TP maintenance
|
|
entity."
|
|
INDEX { sleMplsTpOamFmInfoMegIndex, sleMplsTpOamFmInfoMeIndex, sleMplsTpOamFmInfoMpIndex }
|
|
::= { sleMplsTpOamFmInfoTable 1 }
|
|
|
|
|
|
SleMplsTpOamFmInfoEntry ::=
|
|
SEQUENCE {
|
|
sleMplsTpOamFmInfoMeIndex
|
|
Unsigned32,
|
|
sleMplsTpOamFmInfoMpIndex
|
|
Unsigned32,
|
|
sleMplsTpOamFmInfoFaultManagement
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoRefreshTime
|
|
Unsigned32,
|
|
sleMplsTpOamFmInfoLockInstruct
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLockInstructRefreshTime
|
|
Unsigned32,
|
|
sleMplsTpOamFmInfoAlarmIndication
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoAlarmIndicationInterval
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoAlarmIndicationLevel
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLock
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLockInterval
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLockLevel
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLoopBack
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLoopBackStatus
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoLockInstructStatus
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoFaultManagementStatus
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoCcCvStatus
|
|
INTEGER,
|
|
sleMplsTpOamFmInfoStatus
|
|
INTEGER
|
|
}
|
|
|
|
sleMplsTpOamFmInfoMeIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG."
|
|
::= { sleMplsTpOamFmInfoEntry 1 }
|
|
|
|
|
|
sleMplsTpOamFmInfoMpIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the maintenance point index, used to create
|
|
multiple MEPs in a node of single ME. The value of this
|
|
object can be MEP index or MIP index. Managers should
|
|
obtain new values for row creation in this table by reading
|
|
mplsOamIdMeMpIndexNext."
|
|
::= { sleMplsTpOamFmInfoEntry 2 }
|
|
|
|
|
|
sleMplsTpOamFmInfoFaultManagement OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fault Managment for IETF shows enable or disable"
|
|
DEFVAL { disable }
|
|
::= { sleMplsTpOamFmInfoEntry 3 }
|
|
|
|
|
|
sleMplsTpOamFmInfoRefreshTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used in IETF-based Fault Management RefreshTimer."
|
|
DEFVAL { 0 }
|
|
::= { sleMplsTpOamFmInfoEntry 4 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLockInstruct OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lock instruct for IETF shows enable or disable"
|
|
DEFVAL { disable }
|
|
::= { sleMplsTpOamFmInfoEntry 5 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLockInstructRefreshTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..20)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used in IETF-based lock RefreshTimer."
|
|
DEFVAL { 0 }
|
|
::= { sleMplsTpOamFmInfoEntry 6 }
|
|
|
|
|
|
sleMplsTpOamFmInfoAlarmIndication OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm indication for ITUT shows enable or disable."
|
|
DEFVAL { disable }
|
|
::= { sleMplsTpOamFmInfoEntry 7 }
|
|
|
|
|
|
sleMplsTpOamFmInfoAlarmIndicationInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
oneSecond(1),
|
|
sixtySeconds(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is object to display the itut alarm indication interval value. "
|
|
::= { sleMplsTpOamFmInfoEntry 8 }
|
|
|
|
|
|
sleMplsTpOamFmInfoAlarmIndicationLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object to display the Itut alarm indication Level value. "
|
|
::= { sleMplsTpOamFmInfoEntry 9 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLock OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used in ITUT-based lock. This object will enable/disable the lock"
|
|
DEFVAL { disable }
|
|
::= { sleMplsTpOamFmInfoEntry 10 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLockInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
oneSecond(1),
|
|
sixtySeconds(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to display the ITUT based Lock Interval. "
|
|
::= { sleMplsTpOamFmInfoEntry 11 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLockLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to Display the ITUT based Lock Level. "
|
|
::= { sleMplsTpOamFmInfoEntry 12 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLoopBack OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Object is used in IETF-based loop back. This will show enable/disable loop back ."
|
|
DEFVAL { 2 }
|
|
::= { sleMplsTpOamFmInfoEntry 13 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLoopBackStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object to display the Status of IETF Based LoopBackStatus."
|
|
DEFVAL { 2 }
|
|
::= { sleMplsTpOamFmInfoEntry 14 }
|
|
|
|
|
|
sleMplsTpOamFmInfoLockInstructStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object to display the Status of IETF Based LockInstruct."
|
|
DEFVAL { 2 }
|
|
::= { sleMplsTpOamFmInfoEntry 15 }
|
|
|
|
|
|
sleMplsTpOamFmInfoFaultManagementStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object to display the Status of IETF Based FaultManagement."
|
|
DEFVAL { 2 }
|
|
::= { sleMplsTpOamFmInfoEntry 16 }
|
|
|
|
|
|
sleMplsTpOamFmInfoCcCvStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object to display the Status of IETF Based CC-CV."
|
|
DEFVAL { 2 }
|
|
::= { sleMplsTpOamFmInfoEntry 17 }
|
|
|
|
|
|
sleMplsTpOamFmInfoStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
pathNotAssociated(1),
|
|
pathAssociateWithAnotherMe(2),
|
|
pathDown(3),
|
|
receivedAisFmMessage(4),
|
|
receviedLkrFmMessage(5),
|
|
bfdDetecLoc(6),
|
|
serverLayerDown(7),
|
|
invalidMe(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to display the IETF Status
|
|
1- path not Associated.
|
|
2- path associated with another me.
|
|
3- path down
|
|
4- received AIS Message.
|
|
5- received LKR FM Message.
|
|
6- Bfd Detected Loc.
|
|
7- Server Layer Down.
|
|
8- Invalid Me."
|
|
::= { sleMplsTpOamFmInfoEntry 18 }
|
|
|
|
|
|
sleMplsTpOamFmControlTable OBJECT IDENTIFIER ::= { sleMplsTpOamFm 2 }
|
|
|
|
|
|
sleMplsTpOamFmControlRequest OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
setSleMplsTpOamFmControlInit(1),
|
|
unsetSleMplsTpOamFmControlInit(2),
|
|
setSleMplsTpOamItutAis(3),
|
|
unsetSleMplsTpOamItutAis(4),
|
|
setSleMplsTpOamItutLockInterval(5),
|
|
unsetSleMplsTpOamItutLockInterval(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the configuration commands, and user can configure functions via setting this entry as proper value."
|
|
::= { sleMplsTpOamFmControlTable 1 }
|
|
|
|
|
|
sleMplsTpOamFmControlStatus OBJECT-TYPE
|
|
SYNTAX SleControlStatusType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"status of user command. User have to check this value as .busy. or .idle. before do setRequest."
|
|
::= { sleMplsTpOamFmControlTable 2 }
|
|
|
|
|
|
sleMplsTpOamFmControlTimer OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the wait-time until setRequest end. In case of short-time command, this value is 0"
|
|
::= { sleMplsTpOamFmControlTable 3 }
|
|
|
|
|
|
sleMplsTpOamFmControlTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"the time stamp of the last command. (don.t care)"
|
|
::= { sleMplsTpOamFmControlTable 4 }
|
|
|
|
|
|
sleMplsTpOamFmControlReqResult OBJECT-TYPE
|
|
SYNTAX SleControlRequestResultType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Result of the last command."
|
|
::= { sleMplsTpOamFmControlTable 5 }
|
|
|
|
|
|
sleMplsTpOamFmControlMegName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEG."
|
|
::= { sleMplsTpOamFmControlTable 6 }
|
|
|
|
|
|
sleMplsTpOamFmControlMeName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a ME."
|
|
::= { sleMplsTpOamFmControlTable 7 }
|
|
|
|
|
|
sleMplsTpOamFmControlMepId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..8191)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies a maintenance entity index within
|
|
a MEP."
|
|
::= { sleMplsTpOamFmControlTable 8 }
|
|
|
|
|
|
sleMplsTpOamFmInit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
faultMeasurment(1),
|
|
lockInstruct(2),
|
|
loopBack(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used for setting the fault Measurments for IETF/ITUT based upon gloable configuration
|
|
1) Fault measurment is for IETF
|
|
2) Lock-Instruct is for IETF
|
|
3) LoopBack to configure for IETF "
|
|
::= { sleMplsTpOamFmControlTable 9 }
|
|
|
|
|
|
sleMplsTpOamFmControlRefreshTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This varible is used to set the Refresh Time for IETF of 2 objects ie., Fault managment and Lock Instruct
|
|
1) Fault managment range (1-20)
|
|
2) Lock-Instruct range (1-255)"
|
|
::= { sleMplsTpOamFmControlTable 10 }
|
|
|
|
|
|
sleMplsTpOamFmControlInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
oneOne(1),
|
|
sixtyOne(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable is used to set the interval for 2 alarm-inidaction and lock objects of ITUT"
|
|
::= { sleMplsTpOamFmControlTable 11 }
|
|
|
|
|
|
sleMplsTpOamFmControlLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This varible is used to set the level for Alarm indication and lock objects of ITUT"
|
|
::= { sleMplsTpOamFmControlTable 12 }
|
|
|
|
|
|
|
|
END
|
|
|
|
--
|
|