- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
24419 lines
707 KiB
Text
24419 lines
707 KiB
Text
-- **************************************************************
|
|
-- Cerent-454-MIB module
|
|
--
|
|
-- This module contains the objects and events for the
|
|
-- Cisco ONS 15454
|
|
|
|
-- Copyright (c) 1998-1999 by Cerent Corporation, Inc.
|
|
-- Copyright (c) 2000-2002, 2004-2005 by Cisco Systems, Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- **************************************************************
|
|
|
|
CERENT-454-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
OBJECT-IDENTITY,
|
|
NOTIFICATION-TYPE,
|
|
Integer32,
|
|
Unsigned32,
|
|
Counter32
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,
|
|
DisplayString,
|
|
TruthValue,
|
|
TimeStamp
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
cerentProducts,
|
|
cerentModules
|
|
FROM CERENT-GLOBAL-REGISTRY
|
|
CerentNotificationClass,
|
|
CerentAlarmSeverity,
|
|
CerentAlarmStatus,
|
|
CerentAlarmServiceAffecting,
|
|
CerentMonitorType,
|
|
CerentLocation,
|
|
CerentPeriod,
|
|
CerentPortNumber
|
|
FROM CERENT-TC;
|
|
|
|
cerent454MibModule MODULE-IDENTITY
|
|
LAST-UPDATED "0410010000Z" -- 2004/Oct/01
|
|
ORGANIZATION "Cisco Systems, Inc."
|
|
CONTACT-INFO
|
|
" support@Cisco.com
|
|
|
|
Postal: Cisco Systems
|
|
1450 N. McDowell Blvd.
|
|
Petaluma, CA 94954
|
|
USA
|
|
|
|
Tel: +1-877-323-7368"
|
|
DESCRIPTION
|
|
"This module provides the definitions for
|
|
objects for managing Cisco OTBU ONS 15454."
|
|
|
|
REVISION "0410010000Z" -- 2004/Oct/01
|
|
DESCRIPTION
|
|
"This file can be used with R5.0 release."
|
|
|
|
::= { cerentModules 20 }
|
|
|
|
cerent454Mib OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The is the node under which all Cisco ONS 15454
|
|
specific mib object are located."
|
|
::= { cerentProducts 10 }
|
|
|
|
cerent454Conformance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This node is created compliance. Has
|
|
objects as required by the RFCs"
|
|
::= { cerent454Mib 10 }
|
|
|
|
-- ********************************************************
|
|
|
|
cerentCommonObjects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects here are expected to be
|
|
used by all Cisco OTBU Products.
|
|
These will be mixed with specific
|
|
objects of the product-specific branch."
|
|
::= { cerent454Mib 100 }
|
|
--
|
|
cerentCommonEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This branch is similar to cerentCommonObjects,
|
|
except that this will have only events"
|
|
::= { cerent454Mib 200 }
|
|
|
|
-- ********************************************************
|
|
|
|
cerent454Groups OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cerent454Conformance 10 }
|
|
|
|
cerent454Compliance OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cerent454Conformance 20 }
|
|
|
|
-- **************************************************************
|
|
-- Cisco ONS 15454 specific textual conventions
|
|
-- **************************************************************
|
|
|
|
Cerent454AlarmType ::= TEXTUAL-CONVENTION
|
|
-- DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This TC is used by the NMS to map the alarm type
|
|
received by the trap and and display the string
|
|
shown in LHS."
|
|
SYNTAX INTEGER {
|
|
alarmUnknown ( 1 ),
|
|
alarmCutoffIsInManualMode ( 10 ),
|
|
failureDetectedExternalToTheNE ( 20 ),
|
|
externalError ( 30 ),
|
|
excessiveSwitching ( 40 ),
|
|
sdccTerminationFailure ( 50 ),
|
|
incomingFailureCondition ( 60 ),
|
|
alarmIndicationSignal ( 70 ),
|
|
alarmIndicationSignalLine ( 80 ),
|
|
alarmIndicationSignalPath ( 90 ),
|
|
alarmIndicationSignalVT ( 100 ),
|
|
apsChannelFailure ( 110 ),
|
|
channelByteFailureAPS ( 120 ),
|
|
channelProtectionSwitchingChannelMatchFailureAPS ( 130 ),
|
|
channelAutomaticProtectionSwitchModeMismatchAPS ( 140 ),
|
|
farEndProtectionLineFailure ( 150 ),
|
|
inconsistentAPSCode ( 160 ),
|
|
improperAPSCode ( 170 ),
|
|
nodeIdMismatch ( 180 ),
|
|
channelDefaultKAPS ( 190 ),
|
|
connectionLoss ( 200 ),
|
|
|
|
bipolarViolation ( 210 ),
|
|
carrierLossOnTheLAN ( 220 ),
|
|
concatenationErrorSTS ( 230 ),
|
|
excessCollisionsOnTheLAN ( 240 ),
|
|
facilityFailure ( 250 ),
|
|
farEndAIS ( 260 ),
|
|
farEndMultipleDS1LOSDetectedOnDS3 ( 270 ),
|
|
farEndDS1EqptFailNonServiceAffecting ( 280 ),
|
|
farEndDS1EqptFailServiceAffecting ( 290 ),
|
|
farEndSingleDS1LOS ( 300 ),
|
|
farEndDS3EqptFailNonServiceAffecting ( 310 ),
|
|
farEndDS3EqptFailServiceAffecting ( 320 ),
|
|
farEndCommonEquipmentFailureNonServiceAffecting ( 330 ),
|
|
farEndIDLE ( 340 ),
|
|
farEndLOS ( 350 ),
|
|
farEndLOF ( 360 ),
|
|
farEndBlockError ( 370 ),
|
|
ds3IdleCondition ( 380 ),
|
|
lossOfFrame ( 390 ),
|
|
lossOfPointer ( 400 ),
|
|
|
|
lossOfPointerPath ( 410 ),
|
|
lossOfPointerVT ( 420 ),
|
|
lossOfSignal ( 430 ),
|
|
outOfFrame ( 440 ),
|
|
pathSelectorFailure ( 450 ),
|
|
remoteAlarmIndication ( 460 ),
|
|
remoteFailureIndication ( 470 ),
|
|
remoteFailureIndicationLine ( 480 ),
|
|
remoteFailureIndicationPath ( 490 ),
|
|
remoteFailureIndicationVT ( 500 ),
|
|
|
|
signalDegrade ( 510 ),
|
|
severelyErroredFrame ( 520 ),
|
|
signalFailure ( 530 ),
|
|
signalLabelMismatchFailure ( 540 ),
|
|
payloadDefectIndication ( 550 ),
|
|
|
|
payloadDefectIndicationPath ( 560 ),
|
|
payloadLabelMismatchPath ( 570 ),
|
|
signalLabelMismatchFailurePayloadLabelMismatchVT ( 580 ),
|
|
unequippedPath ( 590 ),
|
|
signalLabelMismatchFailureUnequippedVT ( 600 ),
|
|
lossOfSynchronization ( 610 ),
|
|
outOfSynchronization ( 620 ),
|
|
primarySynchronizationReferenceFailure ( 630 ),
|
|
secondarySynchronizationReferenceFailure ( 640 ),
|
|
thirdSynchronizationReferenceFailure ( 650 ),
|
|
fourthSynchronizationReferenceFailure ( 660 ),
|
|
fifthSynchronizationReferenceFailure ( 670 ),
|
|
sixthSynchronizationReferenceFailure ( 680 ),
|
|
|
|
failedToReceiveSynchronizationStatusMessage ( 690 ),
|
|
synchronizationStatusMessagesAreDisabledOnThisInterface ( 700 ),
|
|
stratum1PrimaryReferenceSourceTraceable ( 710 ),
|
|
synchronizedTraceabilityUnknown ( 720 ),
|
|
stratum2Traceable ( 730 ),
|
|
transitNodeClockTraceable ( 740 ),
|
|
|
|
stratum3ETraceable ( 750 ),
|
|
stratum3Traceable ( 760 ),
|
|
sonetMinimumClockTraceable ( 770 ),
|
|
stratum4Traceable ( 780 ),
|
|
doNotUseForSynchronization ( 790 ),
|
|
reservedForNetworkSynchronizationUse ( 800 ),
|
|
|
|
outgoingFailureCondition ( 810 ),
|
|
remoteDefectIndicationLine ( 820 ),
|
|
remoteDefectIndicationPath ( 830 ),
|
|
freeRunningSynchronizationMode ( 840 ),
|
|
holdoverSynchronizationMode ( 850 ),
|
|
fastStartSynchronizationMode ( 860 ),
|
|
internalFault ( 870 ),
|
|
internalError ( 880 ),
|
|
internalMessageError ( 890 ),
|
|
mismatchOfEquipmentAndAttributes ( 900 ),
|
|
watchdogTimerTimeout ( 910 ),
|
|
softwareFaultOrFailure ( 920 ),
|
|
softwareFaultDataIntegrityFault ( 930 ),
|
|
programFailure ( 940 ),
|
|
|
|
controlEquipmentFailure ( 950 ),
|
|
primaryNonVolatileBackupMemoryFailure ( 960 ),
|
|
secondaryNonVolatileBackupMemoryFailure ( 970 ),
|
|
controlBusFailure ( 980 ),
|
|
controlBus1Failure ( 990 ),
|
|
controlBus2Failure ( 1000 ),
|
|
|
|
tccAToShelfSlot1DROP1CommunicationFailure ( 1010 ),
|
|
tccAToShelfSlot2DROP2CommunicationFailure ( 1020 ),
|
|
tccAToShelfSlot3DROP3CommunicationFailure ( 1030 ),
|
|
tccAToShelfSlot4DROP4CommunicationFailure ( 1040 ),
|
|
tccAToShelfSlot5TRUNK1CommunicationFailure ( 1050 ),
|
|
tccAToShelfSlot6TRUNK2CommunicationFailure ( 1060 ),
|
|
tccAToShelfSlot7TCCACommunicationFailure ( 1070 ),
|
|
tccAToShelfSlot8XCONACommunicationFailure ( 1080 ),
|
|
tccAToShelfSlot9AICCommunicationFailure ( 1090 ),
|
|
tccAToShelfSlot10XCONBCommunicationFailure ( 1100 ),
|
|
tccAToShelfSlot11TCCBCommunicationFailure ( 1110 ),
|
|
tccAToShelfSlot12TRUNK3CommunicationFailure ( 1120 ),
|
|
tccAToShelfSlot13TRUNK4CommunicationFailure ( 1130 ),
|
|
tccAToShelfSlot14DROP5CommunicationFailure ( 1140 ),
|
|
tccAToShelfSlot15DROP6CommunicationFailure ( 1150 ),
|
|
tccAToShelfSlot16DROP7CommunicationFailure ( 1160 ),
|
|
tccAToShelfSlot17DROP8CommunicationFailure ( 1170 ),
|
|
tccAToDCCAProcessorCommunicationFailure ( 1180 ),
|
|
tccBToShelfSlot1DROP1CommunicationFailure ( 1190 ),
|
|
tccBToShelfSlot2DROP2CommunicationFailure ( 1200 ),
|
|
tccBToShelfSlot3DROP3CommunicationFailure ( 1210 ),
|
|
tccBToShelfSlot4DROP4CommunicationFailure ( 1220 ),
|
|
tccBToShelfSlot5TRUNK1CommunicationFailure ( 1230 ),
|
|
tccBToShelfSlot6TRUNK2CommunicationFailure ( 1240 ),
|
|
tccBToShelfSlot7TCCACommunicationFailure ( 1250 ),
|
|
tccBToShelfSlot8XCONACommunicationFailure ( 1260 ),
|
|
tccBToShelfSlot9AICCommunicationFailure ( 1270 ),
|
|
tccBToShelfSlot10XCONBCommunicationFailure ( 1280 ),
|
|
tccBToShelfSlot11TCCBCommunicationFailure ( 1290 ),
|
|
tccBToShelfSlot12TRUNK3CommunicationFailure ( 1300 ),
|
|
tccBToShelfSlot13TRUNK4CommunicationFailure ( 1310 ),
|
|
tccBToShelfSlot14DROP5CommunicationFailure ( 1320 ),
|
|
tccBToShelfSlot15DROP6CommunicationFailure ( 1330 ),
|
|
tccBToShelfSlot16DROP7CommunicationFailure ( 1340 ),
|
|
tccBToShelfSlot17DROP8CommunicationFailure ( 1350 ),
|
|
tccBToDCCBProcessorCommunicationFailure ( 1360 ),
|
|
|
|
controlEquipmentControlCommunicationsEquipmentFailure ( 1370 ),
|
|
controlProcessorFailure ( 1380 ),
|
|
workingMemoryFailure ( 1390 ),
|
|
|
|
interconnectionEquipmentFailure ( 1400 ),
|
|
payloadBusFailureToIOSlot1XCONSlot8 ( 1410 ),
|
|
payloadBusFailureToIOSlot2XCONSlot8 ( 1420 ),
|
|
payloadBusFailureToIOSlot3XCONSlot8 ( 1430 ),
|
|
payloadBusFailureToIOSlot4XCONSlot8 ( 1440 ),
|
|
payloadBusFailureToIOSlot5XCONSlot8 ( 1450 ),
|
|
payloadBusFailureToIOSlot6XCONSlot8 ( 1460 ),
|
|
payloadBusFailureToIOSlot12XCONSlot8 ( 1470 ),
|
|
payloadBusFailureToIOSlot13XCONSlot8 ( 1480 ),
|
|
payloadBusFailureToIOSlot14XCONSlot8 ( 1490 ),
|
|
payloadBusFailureToIOSlot15XCONSlot8 ( 1500 ),
|
|
payloadBusFailureToIOSlot16XCONSlot8 ( 1510 ),
|
|
payloadBusFailureToIOSlot17XCONSlot8 ( 1520 ),
|
|
payloadBusFailureToIOSlot1XCONSlot10 ( 1530 ),
|
|
payloadBusFailureToIOSlot2XCONSlot10 ( 1540 ),
|
|
payloadBusFailureToIOSlot3XCONSlot10 ( 1550 ),
|
|
payloadBusFailureToIOSlot4XCONSlot10 ( 1560 ),
|
|
payloadBusFailureToIOSlot5XCONSlot10 ( 1570 ),
|
|
payloadBusFailureToIOSlot6XCONSlot10 ( 1580 ),
|
|
payloadBusFailureToIOSlot12XCONSlot10 ( 1590 ),
|
|
payloadBusFailureToIOSlot13XCONSlot10 ( 1600 ),
|
|
payloadBusFailureToIOSlot14XCONSlot10 ( 1610 ),
|
|
payloadBusFailureToIOSlot15XCONSlot10 ( 1620 ),
|
|
payloadBusFailureToIOSlot16XCONSlot10 ( 1630 ),
|
|
payloadBusFailureToIOSlot17XCONSlot10 ( 1640 ),
|
|
timeSlotInterchangeEquipmentFailure ( 1650 ),
|
|
|
|
equipmentFailure ( 1660 ),
|
|
highTemperature ( 1670 ),
|
|
invalidMACAddress ( 1680 ),
|
|
boardFailure ( 1690 ),
|
|
diagnosticFailure ( 1700 ),
|
|
mediumAccessControlFailure ( 1710 ),
|
|
facilityTerminationEquipmentFailure ( 1720 ),
|
|
automaticLaserShutoffDueToHighTemperature ( 1730 ),
|
|
failureToReleaseFromProtection ( 1740 ),
|
|
receiverFailure ( 1750 ),
|
|
transmitFailure ( 1760 ),
|
|
facilityTerminationEquipmentReceiverMissing ( 1770 ),
|
|
facilityTerminationEquipmentTransmitterMissing ( 1780 ),
|
|
failureToSwitchToProtection ( 1790 ),
|
|
failureToSwitchToProtectionRing ( 1800 ),
|
|
|
|
failureToSwitchToProtectionSpan ( 1810 ),
|
|
failureToSwitchToProtectionPath ( 1820 ),
|
|
fanFailure ( 1830 ),
|
|
equipmentUnitPlugIn ( 1840 ),
|
|
nePowerFailureAtConnector ( 1850 ),
|
|
fuseAlarm ( 1860 ),
|
|
synchronizationUnitFailure ( 1870 ),
|
|
synchronizationSwitchingEquipmentFailure ( 1880 ),
|
|
equipmentUnitUnplugged ( 1890 ),
|
|
loopback ( 1900 ),
|
|
|
|
ds1LoopbackDueToFEACCommand ( 1910 ),
|
|
loopbackCommandSentToFarEndDS1 ( 1920 ),
|
|
ds3LoopbackDueToFEACCommand ( 1930 ),
|
|
ds3LoopbackCommandSentToFarEnd ( 1940 ),
|
|
ds2LoopbackDueToFarEndCommand ( 1950 ),
|
|
ds2LoopbackCommandSentToFarEnd ( 1960 ),
|
|
facilityLoopback ( 1970 ),
|
|
networkLoopback ( 1980 ),
|
|
terminalLoopback ( 1990 ),
|
|
manuallyCausedAbnormalCondition ( 2000 ),
|
|
ethernetBridgeIsNewRootOfSpanningTree ( 2010 ),
|
|
ethernetBridgeTopologyChange ( 2020 ),
|
|
normalCondition ( 2030 ),
|
|
embeddedOperationsChannelFailureLinkDown ( 2040 ),
|
|
peerStateMismatch ( 2050 ),
|
|
proceduralError ( 2060 ),
|
|
improperRemoval ( 2070 ),
|
|
duplicateNodeID ( 2080 ),
|
|
blsrOutOfSync ( 2090 ),
|
|
blsrMultiNodeTableUpdateCompleted ( 2100 ),
|
|
protectionUnitNotAvailable ( 2110 ),
|
|
performanceMonitorThresholdCrossingAlert ( 2120 ),
|
|
protectionSwitch ( 2130 ),
|
|
recoveryOrServiceProtectionActionHasBeenInitiated ( 2140 ),
|
|
automaticSystemReset ( 2150 ),
|
|
automaticUPSRSwitchCausedByAIS ( 2160 ),
|
|
automaticUPSRSwitchCausedByLOP ( 2170 ),
|
|
automaticUPSRSwitchCausedByUNEQ ( 2180 ),
|
|
automaticUPSRSwitchCausedByPDI ( 2190 ),
|
|
automaticUPSRSwitchCausedBySFBER ( 2200 ),
|
|
automaticUPSRSwitchCausedBySDBER ( 2210 ),
|
|
coldRestart ( 2220 ),
|
|
forcedSwitchBackToWorking ( 2230 ),
|
|
forcedSwitchBackToWorkingRing ( 2240 ),
|
|
forcedSwitchBackToWorkingSpan ( 2250 ),
|
|
forcedSwitchToProtection ( 2260 ),
|
|
|
|
forcedSwitchToProtectionRing ( 2270 ),
|
|
forcedSwitchToProtectionSpan ( 2280 ),
|
|
workingFacilityOrEquipmentForcedToSwitchToProtectionPath ( 2290 ),
|
|
|
|
initializationInitiated ( 2300 ),
|
|
lockoutOfProtection ( 2310 ),
|
|
lockoutOfProtectionRing ( 2320 ),
|
|
lockoutOfProtectionSpan ( 2330 ),
|
|
lockoutOfProtectionPath ( 2340 ),
|
|
lockoutOfWorking ( 2350 ),
|
|
lockoutOfWorkingRing ( 2360 ),
|
|
lockoutOfWorkingSpan ( 2370 ),
|
|
|
|
manualSystemReset ( 2380 ),
|
|
|
|
manualSwitchToInternalClock ( 2390 ),
|
|
manualSwitchToPrimaryReference ( 2400 ),
|
|
manualSwitchToSecondReference ( 2410 ),
|
|
manualSwitchToThirdReference ( 2420 ),
|
|
manualSwitchToFourthReference ( 2430 ),
|
|
manualSwitchToFifthReference ( 2440 ),
|
|
manualSwitchToSixthReference ( 2450 ),
|
|
|
|
manualSwitchBackToWorking ( 2460 ),
|
|
manualSwitchBackToWorkingRing ( 2470 ),
|
|
manualSwitchBackToWorkingSpan ( 2480 ),
|
|
manualSwitchToProtection ( 2490 ),
|
|
manualSwitchToProtectionRing ( 2500 ),
|
|
manualSwitchToProtectionSpan ( 2510 ),
|
|
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath ( 2520 ),
|
|
|
|
powerfailRestart ( 2530 ),
|
|
ringIsSquelchingTraffic ( 2540 ),
|
|
softwareDownloadInProgress ( 2550 ),
|
|
|
|
switchToInternalClock ( 2560 ),
|
|
switchToPrimaryReference ( 2570 ),
|
|
switchToSecondReference ( 2580 ),
|
|
switchToThirdReference ( 2590 ),
|
|
switchToFourthReference ( 2600 ),
|
|
switchToFifthReference ( 2610 ),
|
|
switchToSixthReference ( 2620 ),
|
|
|
|
systemReboot ( 2630 ),
|
|
switchedBackToWorking ( 2640 ),
|
|
switchedToProtection ( 2650 ),
|
|
warmRestart ( 2660 ),
|
|
ringIsInWaitToRestoreState ( 2670 ),
|
|
manualSwitchRequest ( 2680 ),
|
|
forcedSwitchRequest ( 2690 ),
|
|
lockoutSwitchRequest ( 2700 ),
|
|
|
|
rmonHistoriesAndAlarmsResetReboot ( 2710 ),
|
|
rmonThresholdCrossingAlarm ( 2720 ),
|
|
alarmsSuppressedByUserCommand ( 2730 ),
|
|
alarmsSuppressedForMaintenance ( 2740 ),
|
|
switchingMatrixModuleFailure ( 2750 ),
|
|
lanConnectionPolarityReversed ( 2760 ),
|
|
autonomousPMReportMessageInhibited ( 2780 ),
|
|
ioSlotToXCONCommunicationFailure ( 2790 ),
|
|
|
|
-- Intentional gap
|
|
|
|
stsPathTraceIdentifierMismatch ( 2800 ),
|
|
nePowerFailureAtConnectorA ( 2810 ),
|
|
nePowerFailureAtConnectorB ( 2820 ),
|
|
freeMemoryOnCardVeryLow ( 2830 ),
|
|
freeMemoryOnCardNearZero ( 2840 ),
|
|
|
|
exerciseRequestOnRing ( 2850 ),
|
|
exerciseRequestOnSpan ( 2860 ),
|
|
squelchingPath ( 2870 ),
|
|
extraTrafficPreempted ( 2880 ),
|
|
|
|
farEndLockoutOfWorkingRing ( 2890 ),
|
|
farEndLockoutOfWorkingSpan ( 2900 ),
|
|
farEndLockoutOfProtectionRing ( 2910 ),
|
|
farEndLockoutOfProtectionAllSpans ( 2920 ),
|
|
|
|
farEndWorkingFacilityForcedToSwitchToProtectionRing ( 2930 ),
|
|
farEndWorkingFacilityForcedToSwitchToProtectionSpan ( 2940 ),
|
|
|
|
farEndManualSwitchOfWorkingFacilityToProtectionRing ( 2950 ),
|
|
farEndManualSwitchOfWorkingFacilityToProtectionSpan ( 2960 ),
|
|
farEndExercisingRing ( 2970 ),
|
|
farEndExercisingSpan ( 2980 ),
|
|
farEndBERThresholdPassedForSignalFailureRing ( 2990 ),
|
|
farEndBERThresholdPassedForSignalFailureSpan ( 3000 ),
|
|
farEndBERThresholdPassedForSignalDegradeRing ( 3010 ),
|
|
farEndBERThresholdPassedForSignalDegradeSpan ( 3020 ),
|
|
apsChannelFarEndProtectionLineSignalDegrade ( 3030 ),
|
|
|
|
ringSwitchIsActiveOnTheEastSide ( 3040 ),
|
|
ringSwitchIsActiveOnTheWestSide ( 3050 ),
|
|
spanSwitchIsActiveOnTheEastSide ( 3060 ),
|
|
spanSwitchIsActiveOnTheWestSide ( 3070 ),
|
|
|
|
uniDirectionalFullPassThroughIsActive ( 3080 ),
|
|
biDirectionalFullPassThroughIsActive ( 3090 ),
|
|
|
|
kBytesPassThroughIsActive ( 3100 ),
|
|
ringIsSegmented ( 3110 ),
|
|
ringTopologyIsUnderConstruction ( 3120 ),
|
|
|
|
lockoutOfProtectionAllSpans ( 3130 ),
|
|
farEndOfFiberIsProvisionedWithDifferentRingID ( 3140 ),
|
|
bothEndsOfFiberProvisionedAsEastOrBothAsWest ( 3150 ),
|
|
securityInvalidLoginUsernameSeeAuditTrail ( 3160 ),
|
|
|
|
autonomousMessagesInhibited ( 3170 ),
|
|
trafficStormOnLANLANTemporarilyDisabled ( 3180 ),
|
|
|
|
reptdbchgMessagesInhibited ( 3190 ),
|
|
securityUserIDHasExpired ( 3200 ),
|
|
partialFanFailure ( 3210 ),
|
|
forcedSwitchRequestOnRing ( 3220 ),
|
|
forcedSwitchRequestOnSpan ( 3230 ),
|
|
lockoutSwitchRequestOnRing ( 3240 ),
|
|
lockoutSwitchRequestOnSpan ( 3250 ),
|
|
manualSwitchRequestOnRing ( 3260 ),
|
|
manualSwitchRequestOnSpan ( 3270 ),
|
|
|
|
communicationFailurePeerToPeerSlotControlBusA ( 3280 ),
|
|
communicationFailurePeerToPeerSlotControlBusB ( 3290 ),
|
|
controllerAToShelfSlotCommunicationFailure ( 3300 ),
|
|
controllerBToShelfSlotCommunicationFailure ( 3310 ),
|
|
|
|
interconnectionEquipmentFailureWorkingPayloadBus ( 3320 ),
|
|
interconnectionEquipmentFailureProtectPayloadBus ( 3330 ),
|
|
inhibitSwitchToProtectRequestOnEquipment ( 3340 ),
|
|
inhibitSwitchToWorkingRequestOnEquipment ( 3350 ),
|
|
|
|
berThresholdExceededForSignalDegradeLine ( 3360 ),
|
|
berThresholdExceededForSignalDegradePath ( 3370 ),
|
|
berThresholdExceededForSignalFailureLine ( 3380 ),
|
|
berThresholdExceededForSignalFailurePath ( 3390 ),
|
|
|
|
exercisingRingSuccessfully ( 3400 ),
|
|
exercisingSpanSuccessfully ( 3410 ),
|
|
spanIsInWaitToRestoreState ( 3420 ),
|
|
|
|
exerciseRequestOnRingFailed ( 3430 ),
|
|
exerciseRequestOnSpanFailed ( 3440 ),
|
|
farEndLockoutOfProtectionSpan ( 3450 ),
|
|
|
|
manufacturingDataMemoryEEPROMFailure ( 3460 ),
|
|
replaceableEquipmentOrUnitIsMissing ( 3470 ),
|
|
softwareDownloadFailed ( 3480 ),
|
|
extraTrafficPCADropped ( 3490 ),
|
|
|
|
etherTxOversubscribed ( 3500 ),
|
|
etherRxOverSubscribed ( 3510 ),
|
|
etherTxExcessFlowCtrl ( 3520 ),
|
|
etherRxExcessFlowCtrl ( 3530 ),
|
|
transportLayerFailure ( 3540 ),
|
|
etherTxUnderrun ( 3550 ),
|
|
|
|
synchronizationReferenceFrequencyOutOfBounds ( 3560 ),
|
|
ntpOrSntpHostFailure ( 3570 ),
|
|
peerCardNotResponding ( 3580 ),
|
|
alarmsAndEventsSuppressedForThisObject ( 3590 ),
|
|
ds3FrameFormatMismatch ( 3600 ),
|
|
|
|
waitToRestore ( 3610 ),
|
|
extremeHighVoltBatteryA ( 3620 ),
|
|
extremeLowVoltBatteryA ( 3630 ),
|
|
extremeHighVoltBatteryB ( 3640 ),
|
|
extremeLowVoltBatteryB ( 3650 ),
|
|
iosConfigCopyFailed ( 3660 ),
|
|
iosConfigCopyInProgress ( 3670 ),
|
|
iosConfigCopySuccess ( 3680 ),
|
|
|
|
-- 3660 through 3700 reserverd for R3.3.x releases
|
|
|
|
signalingUnableToSetupCircuit ( 3710 ),
|
|
errorInStartupConfig ( 3712 ),
|
|
noStartupConfig ( 3714 ),
|
|
needToSaveRunningConfig ( 3716 ),
|
|
invalidAlarm ( 3718 ),
|
|
rsvpHelloFSMToNeighborDown ( 3720 ),
|
|
securityInvalidLoginUsername ( 3722 ),
|
|
databaseBackupFailed ( 3724 ),
|
|
databaseRestoreFailed ( 3726 ),
|
|
lmpHelloFSMToControlChannelDown ( 3730 ),
|
|
lmpNeighborDiscoveryHasFailed ( 3740 ),
|
|
unauthorizedIncomingSignalingRequest ( 3750 ),
|
|
auditLog80PercentFull ( 3760 ),
|
|
moduleCommunicationFailure ( 3762 ),
|
|
auditLog100PercentFullOldestRecordsWillBeLost ( 3764 ),
|
|
standbyDatabaseOutOfSync ( 3766 ),
|
|
redundantPowerCapabilityLost ( 3768 ),
|
|
forcedSwitchToPrimaryReference ( 3770 ),
|
|
forcedSwitchToSecondReference ( 3780 ),
|
|
forcedSwitchToThirdReference ( 3790 ),
|
|
forcedSwitchToInternalClock ( 3800 ),
|
|
industrialHighTemperature ( 3805 ),
|
|
|
|
timSectionTraceIdentifierMismatchFailure ( 4000 ),
|
|
aisMultiplexSectionAlarmIndicationSignal ( 4010 ),
|
|
rdiMultiplexSectionRemoteDefectOrAlarmIndication ( 4020 ),
|
|
timHighOrderTraceIdentifierMismatchFailure ( 4030 ),
|
|
aisAdministrationUnitAlarmIndicationSignal ( 4040 ),
|
|
lopAdministrationUnitLossOfPointer ( 4050 ),
|
|
slmfUnequippedHighOrderPathUnequipped ( 4060 ),
|
|
slmfPLMHighOrderPathLabelMismatch ( 4070 ),
|
|
rdiHighOrderRemoteDefectOrAlarmIndication ( 4080 ),
|
|
lopTributaryUnitLossOfPointer ( 4090 ),
|
|
aisTributaryUnitAlarmIndicationSignal ( 4100 ),
|
|
slmfUnequippedLowOrderPathUnequipped ( 4110 ),
|
|
slmfPLMLowOrderPathLabelMismatch ( 4120 ),
|
|
timLowOrderTraceIdentifierMismatchFailure ( 4130 ),
|
|
rfiLowOrderRemoteFailureOrAlarmIndication ( 4140 ),
|
|
g811PrimaryReferenceClockTraceable ( 4150 ),
|
|
g812TransitNodeClockTraceable ( 4160 ),
|
|
g812LocalNodeClockTraceable ( 4170 ),
|
|
g813SynchronousEquipmentTimingSourceTraceable ( 4180 ),
|
|
e1LoopbackDueToFEACCommand ( 4190 ),
|
|
e1LoopbackCommandSentToFarEnd ( 4200 ),
|
|
e3LoopbackDueToFEACCommand ( 4210 ),
|
|
farEndMultipleE1LOSDetectedOnE3 ( 4220 ),
|
|
farEndE1EqptFailNonServiceAffecting ( 4230 ),
|
|
farEndE1EqptFailServiceAffecting ( 4240 ),
|
|
farEndSingleE1LOS ( 4250 ),
|
|
farEndE3EqptFailServiceAffecting ( 4260 ),
|
|
e3LoopbackCommandSentToFarEnd ( 4270 ),
|
|
farEndE3EqptFailNonServiceAffecting ( 4280 ),
|
|
lowVoltBatteryA ( 4290 ),
|
|
highVoltBatteryA ( 4300 ),
|
|
lowVoltBatteryB ( 4310 ),
|
|
highVoltBatteryB ( 4320 ),
|
|
msspRingOutOfSync ( 4330 ),
|
|
msspMultiNodeTableUpdateCompleted ( 4340 ),
|
|
automaticSNCPSwitchCausedByAIS ( 4350 ),
|
|
automaticSNCPSwitchCausedByLOP ( 4360 ),
|
|
automaticSNCPSwitchCausedByUNEQ ( 4370 ),
|
|
automaticSNCPSwitchCausedByPDI ( 4380 ),
|
|
automaticSNCPSwitchCausedBySFBER ( 4390 ),
|
|
automaticSNCPSwitchCausedBySDBER ( 4400 ),
|
|
stmConcatenationError ( 4410 ),
|
|
e3IdleCondition ( 4420 ),
|
|
channelMSSPInconsistentAPSCode ( 4430 ),
|
|
channelMSSPImproperAPSCodeAPS ( 4440 ),
|
|
channelMSSPNodeIdMismatchAPS ( 4450 ),
|
|
channelMSSPDefaultKAPS ( 4460 ),
|
|
channelMSSPConnectionLossAPS ( 4470 ),
|
|
minimumClockTraceableSDH ( 4480 ),
|
|
lineIsInWaitToRestoreStateSDH ( 4490 ),
|
|
berThresholdExceededForSignalDegradeHighOrder ( 4500 ),
|
|
berThresholdExceededForSignalFailureHighOrder ( 4510 ),
|
|
berThresholdExceededForSignalDegradeLowOrder ( 4520 ),
|
|
berThresholdExceededForSignalFailureLowOrder ( 4530 ),
|
|
failureToSwitchToProtectionHighOrderPath ( 4540 ),
|
|
failureToSwitchToProtectionLowOrderPath ( 4550 ),
|
|
lofAdministrationUnitLossOfMultiFrame ( 4560 ),
|
|
sdhSpanIsInWaitToRestoreState ( 4570 ),
|
|
a8b10bOutOfSync ( 4755 ),
|
|
odukPMAlarmIndicationSignal ( 4760 ),
|
|
otukAlarmIndicationSignal ( 4765 ),
|
|
otukSMBackwardDefectIndication ( 4770 ),
|
|
fecUncorrectedWord ( 4780 ),
|
|
gccTerminationFailure ( 4785 ),
|
|
otukIncomingAlignmentError ( 4790 ),
|
|
odukLockedDefectPM ( 4795 ),
|
|
lossOfMultiFrame ( 4800 ),
|
|
odukOpenConnectionIndication ( 4805 ),
|
|
payloadTypeIdentifierMismatch ( 4810 ),
|
|
odukTrailTraceIdentifierMismatch ( 4815 ),
|
|
otukTrailTraceIdentifierMismatch ( 4820 ),
|
|
equipmentHighLaserBias ( 4825 ),
|
|
equipmentHighLaserTemp ( 4830 ),
|
|
equipmentHighLaserPeltier ( 4835 ),
|
|
facilityHighRxPower ( 4840 ),
|
|
equipmentHighTxPower ( 4845 ),
|
|
equipmentHighTransceiverVoltage ( 4850 ),
|
|
equipmentLowLaserBias ( 4855 ),
|
|
equipmentLowLaserTemp ( 4860 ),
|
|
equipmentLowLaserPeltier ( 4865 ),
|
|
facilityLowRxPower ( 4870 ),
|
|
equipmentLowTxPower ( 4875 ),
|
|
equipmentLowTransceiverVoltage ( 4880 ),
|
|
equipmentRxLocked ( 4885 ),
|
|
equipmentSquelched ( 4890 ),
|
|
equipmentTxLocked ( 4895 ),
|
|
otukSignalFailure ( 4900 ),
|
|
odukSignalFailure ( 4905 ),
|
|
otukSignalDegrade ( 4910 ),
|
|
odukSignalDegrade ( 4915 ),
|
|
pluggablePortMissing ( 4920 ),
|
|
pluggablePortRateMismatch ( 4925 ),
|
|
pluggablePortSecurityCodeMismatch ( 4930 ),
|
|
tciNotSelected ( 4935 ),
|
|
tci1ClockFailure ( 4940 ),
|
|
odukPMBackwardDefectIndication ( 4945 ),
|
|
odukTCM1BackwardDefectIndication ( 4950 ),
|
|
odukTCM2BackwardDefectIndication ( 4955 ),
|
|
equipmentHighRxTemperature ( 4960 ),
|
|
equipmentLowRxTemperature ( 4965 ),
|
|
tci2ClockFailure ( 4970 ),
|
|
equipmentWavelengthMismatch ( 4975 ),
|
|
dspCommunicationFailure ( 4980 ),
|
|
dspFailure ( 4985 ),
|
|
laserApproachingEndOfLife ( 5000 ),
|
|
crossconnectLoopback ( 5010 ),
|
|
adminLogoutOfUser ( 5020 ),
|
|
userLockedOut ( 5030 ),
|
|
adminLockoutOfUser ( 5040 ),
|
|
adminLockoutClear ( 5050 ),
|
|
invalidLoginUsername ( 5060 ),
|
|
securityInvalidLoginPassword ( 5070 ),
|
|
securityInvalidLoginLockedOut ( 5080 ),
|
|
securityInvalidLoginAlreadyLoggedOn ( 5090 ),
|
|
loginOfUser ( 5100 ),
|
|
automaticLogoutOfIdleUser ( 5110 ),
|
|
logoutOfUser ( 5120 ),
|
|
enhancedRemoteFailureIndicationPathServer ( 5200 ),
|
|
enhancedRemoteFailureIndicationPathConnectivity ( 5210 ),
|
|
enhancedRemoteFailureIndicationPathPayload ( 5220 ),
|
|
firewallHasBeenDisabled ( 5230 ),
|
|
securityIntrusionDetPwd ( 5240 ),
|
|
securityIntrusionDetUser ( 5250 ),
|
|
connectionEquipmentMismatch ( 5260 ),
|
|
disableInactiveUser ( 5270 ),
|
|
disableInactiveClear ( 5280 ),
|
|
batteryFailure ( 5290 ),
|
|
extremeHighVolt ( 5300 ),
|
|
extremeLowVolt ( 5310 ),
|
|
highVolt ( 5320 ),
|
|
lowVolt ( 5330 ),
|
|
suspendUser ( 5340 ),
|
|
suspendUserClear ( 5350 ),
|
|
lineDccTerminationFailure ( 5360 ),
|
|
multiplexSectionDccTerminationFailure ( 5370 ),
|
|
gigaBitEthernetOutOfSync ( 5380 ),
|
|
sequenceMismatch ( 5390 ),
|
|
lossOfAlignment ( 5400 ),
|
|
outOfUseByAdministrativeCommand ( 5410 ),
|
|
outOfUseTransportFailure ( 5420 ),
|
|
vcatGroupDown ( 5430 ),
|
|
vcatGroupDegraded ( 5440 ),
|
|
vcatGroupIncomplete ( 5450 ),
|
|
alarmIndicationSignalInTX ( 5460 ),
|
|
remoteAlarmIndicationInTX ( 5470 ),
|
|
kByteAPSChannelFailure ( 5480 ),
|
|
apsInvalidMode ( 5490 ),
|
|
ipAddressAlreadyInUseWithinTheSameDccArea ( 5500 ),
|
|
nodeNameInUseWithinTheSameDccArea ( 5510 ),
|
|
rearPanelEthernetLinkRemoved ( 5520 ),
|
|
manualSwitchToProtectResultedInNoTrafficSwitch ( 5530 ),
|
|
manualSwitchBackToWorkingResultedInNoTrafficSwitch ( 5540 ),
|
|
forcedSwitchToProtectResultedInNoTrafficSwitch ( 5550 ),
|
|
forcedSwitchBackToWorkingResultedInNoTrafficSwitch ( 5560 ),
|
|
duplicateSerialNumberDetectedOnAPluggableEntity ( 5570 ),
|
|
lossOfSignalForOpticalChannel ( 5600 ),
|
|
encapsulationMismatchPath ( 5610 ),
|
|
encapsulationMismatchVT ( 5620 ),
|
|
encapsulationMismatchHighOrderPath ( 5630 ),
|
|
encapsulationMismatchLowOrderPath ( 5640 ),
|
|
gfpUserPayloadMismatch ( 5650 ),
|
|
gfpFibreChannelDistanceExtensionMismatch ( 5660 ),
|
|
gfpFibreChannelDistanceExtensionBufferStarvation ( 5670 ),
|
|
gfpFibreChannelDistanceExtensionCreditStarvation ( 5680 ),
|
|
automaticWdmAnsFinished ( 5690 ),
|
|
gfpClientSignalFailDetected ( 5700 ),
|
|
gfpLossOfFrameDelineation ( 5710 ),
|
|
gfpExtensionHeaderMismatch ( 5730 ),
|
|
incomingOverheadSignalAbsent ( 5740 ),
|
|
opticalSafetyRemoteInterlockOn ( 5750 ),
|
|
automaticPowerControlCorrectionSkipped ( 5770 ),
|
|
apcCannotSetValueDueToRangeLimits ( 5780 ),
|
|
lcasVcgMemberTxSideInAddState ( 5790 ),
|
|
farEndManualSwitchBackToWorkingSpan ( 5800 ),
|
|
farEndForcedSwitchBackToWorkingSpan ( 5810 ),
|
|
universalTransponderModuleHardwareFailure ( 5820 ),
|
|
universalTransponderModuleCommunicationFailure ( 5830 ),
|
|
pluginModuleRangeSettingsMismatch ( 5840 ),
|
|
lcasVcgMemberTxSideInDnuState ( 5850 ),
|
|
lcasControlWordCrcCheckFailure ( 5860 ),
|
|
lcasVcgMemberRxSideInFailState ( 5870 ),
|
|
signalLossOnDataInterface ( 5880 ),
|
|
synchronizationLossOnDataInterface ( 5890 ),
|
|
portFAIL ( 5900 ),
|
|
unreachablePortTargetPower ( 5910 ),
|
|
portAddPowerDegradeLow ( 5920 ),
|
|
portAddPowerDegradeHigh ( 5930 ),
|
|
portAddPowerFailLow ( 5940 ),
|
|
portAddPowerFailHigh ( 5950 ),
|
|
automaticPowerControlTerminatedOnManualRequest ( 6000 ),
|
|
oduk1AlarmIndicationSignal ( 6010 ),
|
|
oduk2AlarmIndicationSignal ( 6020 ),
|
|
oduk3AlarmIndicationSignal ( 6030 ),
|
|
oduk4AlarmIndicationSignal ( 6040 ),
|
|
temperatureReadingMismatchBetweenSCCards ( 6050 ),
|
|
voltageReadingMismatchBetweenSCCards ( 6060 ),
|
|
alarmsSuppressedonOutOfGroupVcatMember ( 6070 ),
|
|
blsrSoftwareVersionMismatch ( 6080 ),
|
|
optimized1Plus1ApsPrimaryFacility ( 6090 ),
|
|
optimized1Plus1ApsPrimarySectionMismatch ( 6100 ),
|
|
optimized1Plus1ApsInvalidPrimarySection ( 6110 ),
|
|
compositeClockHighLineVoltage ( 6120 ),
|
|
berThresholdExceededForSignalDegradeVt ( 6130 ),
|
|
berThresholdExceededForSignalFailureVt ( 6140 ),
|
|
spanLengthOutOfRange ( 6150 ),
|
|
idleSignalCondition ( 6170 ),
|
|
idleSignalConditionInTx ( 6180 ),
|
|
vtPathTraceIdentifierMismatch ( 6190 ),
|
|
lossOfFrameInTX ( 6200 ),
|
|
provisioningMismatch ( 6210 ),
|
|
sectionTraceIdentifierMismatch ( 6220 ),
|
|
regeneratorSectionTraceIdentifierMismatch ( 6230 ),
|
|
switchingMatrixModuleFailureWorking ( 6240 ),
|
|
switchingMatrixModuleFailureProtect ( 6250 ),
|
|
slotCommunicationDisabled ( 6260 ),
|
|
sessionTimeLimitExpired ( 6270 ),
|
|
userPasswordChangeRequired ( 6280 ),
|
|
isisAdjacencyFailure ( 6290 ),
|
|
msspSoftwareVersionMismatch ( 6300 ),
|
|
remoteAuthenticationFailSeeAuditLog ( 6310 ),
|
|
ringIsSquelchingStsTraffic ( 6330 ),
|
|
ringIsSquelchingVtTraffic ( 6340 ),
|
|
archiveOfAuditLogFailed ( 6350 ),
|
|
rprWrapped ( 6360 ),
|
|
shelfCommunicationFailure ( 6370 ),
|
|
duplicatedShelfIdentifier ( 6380 ),
|
|
softwareMismatch ( 6390 ),
|
|
lmpFailure ( 6400 ),
|
|
opticalTerminationIncomplete ( 6410 ),
|
|
forwardDefectIndication ( 6420 ),
|
|
payloadMissingIndication ( 6430 ),
|
|
spanMeasurementCannotBePerformed ( 6440 ),
|
|
ringIsSquelchingHighOrderTraffic ( 6450 ),
|
|
ringIsSquelchingLowOrderTraffic ( 6460 ),
|
|
badPacketCountExceedsThreshold ( 6470 ),
|
|
linkLayerKeepAliveFailure ( 6480 ),
|
|
autonegotiationRemoteFailureIndication ( 6490 ),
|
|
trailSignalFail ( 6500 ),
|
|
ds1LoopbackCommandSentToFarEnd ( 6510 ),
|
|
multiplexSectionSignalDegraded ( 6520 ),
|
|
multiplexSectionExcessiveErrors ( 6530 ),
|
|
highOrderPathSignalDegraded ( 6540 ),
|
|
highOrderPathExcessiveErrors ( 6550 ),
|
|
lowOrderPathSignalDegraded ( 6560 ),
|
|
lowOrderPathExcessiveErrors ( 6570 ),
|
|
regeneratorSectionDccTerminationFailure ( 6580 ),
|
|
networkMemoryPoolLow ( 6590 ),
|
|
ospfRoutingTableOverflow ( 6600 ),
|
|
autoLaserShutdownDisabled ( 6610 ),
|
|
rprProtectionIsActive ( 6630 ),
|
|
maxRPRStationNumberExceeded ( 6640 ),
|
|
rprProtectionConfigurationMismatched ( 6650 ),
|
|
reservedBandwidthLinkRateExceededOnRinglet0 ( 6660 ),
|
|
reservedBandwidthLinkRateExceededOnRinglet1 ( 6670 ),
|
|
rprInterfaceInPassThroughMode ( 6680 ),
|
|
rprPeerNodeIsMissing ( 6690 ),
|
|
rprRiFailure ( 6700 ),
|
|
rprSignalFailure ( 6710 ),
|
|
rprSignalDegrade ( 6720 ),
|
|
interlinkFailure ( 6730 ),
|
|
apcWrongGain ( 6740 ),
|
|
rprSpanMismatch ( 6750 ),
|
|
efmRemoteFaultIndicationCriticalEvent ( 6760 ),
|
|
efmRemoteFaultIndicationDyingGasp ( 6770 ),
|
|
efmRemoteFaultIndicationLinkFault ( 6780 ),
|
|
efmLinkMonitoringErroredSymbolPeriodEvent ( 6790 ),
|
|
efmLinkMonitoringErroredFrameEvent ( 6800 ),
|
|
efmLinkMonitoringErroredFramePeriodEvent ( 6810 ),
|
|
efmLinkMonitoringErroredFrameSecondsSummary ( 6820 ),
|
|
efmRemoteLoopbackRequestFailed ( 6830 ),
|
|
fastAutomaticProtectionSwitching ( 6840 ),
|
|
fastAutomaticProtectionSwitchingConfigMismatch ( 6850 ),
|
|
lcasSinkGroupError ( 6860 ),
|
|
lcasVcgMemberRxSideInDnuState ( 6870 ),
|
|
fcDistanceExtFuncNotEstablished ( 6880 ),
|
|
nonCiscoPPMInserted ( 6890 ),
|
|
unqualifiedPPMInserted ( 6900 ),
|
|
ftaMismatch ( 6910 ),
|
|
cardPortsUnableToProvideProtection ( 6920 ),
|
|
lmpSignalDegrade ( 6930 ),
|
|
lmpSignalFailure ( 6940 ),
|
|
lmpUnallocatedDataLink ( 6950 ),
|
|
frontPortLinkLoss ( 6960 ),
|
|
bertEnbl ( 6970 ),
|
|
bertSyncFail ( 6975 ),
|
|
workQueueFull ( 6980 ),
|
|
equipmentPowerFailureAtConnectorA ( 7000 ),
|
|
equipmentPowerFailureAtConnectorB ( 7005 ),
|
|
equipmentPowerFailureAtReturnConnectorA ( 7010 ),
|
|
equipmentPowerFailureAtReturnConnectorB ( 7015 ),
|
|
bridgeAndRollHasOccurred ( 7055 ),
|
|
bridgeAndRollIsPendingAValidSignal ( 7060 ),
|
|
clockBusFailureTscA ( 7160 ),
|
|
clockBusFailureTscB ( 7165 ),
|
|
ospfHelloFail ( 7185 ),
|
|
openIOSlots ( 7200 ),
|
|
lossOfClockFromMateShelfController ( 7210 ),
|
|
virtualLanAlarmIndiacationSignal ( 7225 ),
|
|
dcuLossFailure ( 7230 ),
|
|
ochncMaintenance ( 7235 ),
|
|
ramanLaserShutdown ( 7240 ),
|
|
losOfRamanSignal ( 7245 ),
|
|
mcastMacTableFull ( 7250 ),
|
|
multicastMacAddressAliasing ( 7255 ),
|
|
ramanPwrProtOn ( 7260 ),
|
|
cppPeerNotResponding ( 7265 ),
|
|
voaControlLoopDisableDueToExcessiveCounterPropagationLight ( 7275 ),
|
|
wizardIsRunning ( 7280 ),
|
|
ramanGainNotReached ( 7285 ),
|
|
pprForwardDefectIndication ( 7295 ),
|
|
pprBackwardDefectIndication ( 7300 ),
|
|
pprCoordinatedMaintenance ( 7305 ),
|
|
pprTriggerThresholdBerExceeded ( 7310 ),
|
|
localFault ( 7315 ),
|
|
remoteFault ( 7320 ),
|
|
efmRemoteLoopbackConfigured ( 7325 ),
|
|
efmPeerMissing ( 7330 ),
|
|
eqptDegrade ( 7335 ),
|
|
excessiveBackPropagation ( 7340 ),
|
|
remoteMaintenanceEndPointIsDown ( 7345 ),
|
|
crossConnectedCFMService ( 7350 ),
|
|
cfmLoop ( 7355 ),
|
|
cfmConfigurationError ( 7360 ),
|
|
outOfChannelGroupBundle ( 7365 ),
|
|
repNeighborAdjacencyFailure ( 7370 ),
|
|
repLinkFlapping ( 7375 ),
|
|
faultInREPSegment ( 7380 ),
|
|
primaryREPEdgePortElected ( 7385 ),
|
|
secondaryREPEdgePortElected ( 7390 ),
|
|
stcnREPGenerated ( 7395 ),
|
|
vlbREPActivated ( 7400 ),
|
|
vlbREPTriggerSoakingDelayActive ( 7405 ),
|
|
wanSyncloss ( 7410 ),
|
|
laserShutdownDueToWavelengthDrift ( 7415 ),
|
|
manualLaserRestart ( 7420 ),
|
|
laserShutdownDueToNonCiscoPPMInserted ( 7425 ),
|
|
ethernetOSCTerminationFailure ( 7430 ),
|
|
softwareSignatureVerificationFailed ( 7445 ),
|
|
protectVolumeSoftwareSignatureVerificationFailed ( 7450 ),
|
|
activeVolumeSoftwareSignatureVerificationFailed ( 7455 ),
|
|
peerPortClientSignalFailDetected (7460),
|
|
channelShutdownDueToWavelengthDrift ( 7465 ),
|
|
usbWriteFailure ( 7475 ),
|
|
usbSyncInProgress ( 7480 ),
|
|
autoSensingUnableToDetectValidPayload (7485),
|
|
payloadAutoSensingInProgress (7490),
|
|
gfpClientSignalFailDetectedDueToSigloss (7495),
|
|
gfpClientSignalFailDetectedDueToSyncloss (7500),
|
|
pmdDegrade (7510),
|
|
standbyTccNEClockIsInternalClock ( 7515 ),
|
|
chromaticDispersionValue ( 7520 ),
|
|
packetTransportServiceFailed ( 7525 ),
|
|
satellitePanelDiscoveryFailure ( 7530 ),
|
|
satellitePanelActiveLinkFailure ( 7535 ),
|
|
satellitePanelCommunicationFailure ( 7540 ),
|
|
satellitePanelImproperConfiguration ( 7545 ),
|
|
satellitePanelFanMismatchOfEquipmentAndAttributes ( 7550 ),
|
|
satellitePanelFanFailure ( 7555 ),
|
|
satellitePanelPartialFanFailure ( 7560 ),
|
|
satellitePanelFANManufacturingDataMemoryEEPROMFailure ( 7565 ),
|
|
satellitePanelFANUnitIsMissing ( 7570 ),
|
|
satellitePanelIndustrialHighTemperature ( 7575 ),
|
|
satellitePanelHighTemperature ( 7580 ),
|
|
satellitePanelBatteryFailureA ( 7585 ),
|
|
plannedSwitchOver ( 7590 ),
|
|
protectionCardConfigurationMismatch ( 7595 ),
|
|
routerProcessorSwitchOver ( 7600 ),
|
|
runningLowOnResources ( 7605 ),
|
|
noMoreResourcesAreAvailable ( 7610 ),
|
|
esmcFailure ( 7615 ),
|
|
licenseWillExpireWithin24Hours ( 7620 ),
|
|
licenseWillExpireAnytimeAfter1DayButBefore14Days ( 7625 ),
|
|
licenseIsExpired ( 7630 ),
|
|
licenseCountViolation ( 7635 ),
|
|
temporaryLicenseIsInUse ( 7640 ),
|
|
evaluationLicenseIsInUse ( 7645 ),
|
|
licenseIsMissing ( 7650 ),
|
|
pseudowireDown ( 7655 ),
|
|
workingPseudowireControlPlaneDown ( 7660 ),
|
|
protectPseudowireControlPlaneDown ( 7665 ),
|
|
workingPseudowireConnectivityCheckDown ( 7670 ),
|
|
protectPseudowireConnectivityCheckDown ( 7675 ),
|
|
pseudowireTrafficSwitchedToProtection ( 7680 ),
|
|
workingPseudowireLocalAcTxPortFault ( 7685 ),
|
|
protectPseudowireLocalAcTxPortFault ( 7690 ),
|
|
workingPseudowireLocalAcRxPortFault ( 7695 ),
|
|
protectPseudowireLocalAcRxPortFault ( 7700 ),
|
|
workingPseudowireRemoteAcTxPortFault ( 7705 ),
|
|
protectPseudowireRemoteAcTxPortFault ( 7710 ),
|
|
workingPseudowireRemoteAcRxPortFault ( 7715 ),
|
|
protectPseudowireRemoteAcRxPortFault ( 7720 ),
|
|
slaThresholdCrossAlert ( 7725 ),
|
|
protectLocalPseudowireNotForwarding ( 7730 ),
|
|
workingPseudowireNotForwarding ( 7735 ),
|
|
protectPseudowireNotForwarding ( 7740 ),
|
|
tpTunnelDown ( 7745 ),
|
|
workingLabelSwitchedPathDown ( 7750 ),
|
|
protectLabelSwitchedPathDown ( 7755 ),
|
|
workingLabelSwitchedPathAlarmIndicationSignal ( 7760 ),
|
|
protectLabelSwitchedPathAlarmIndicationSignal ( 7765 ),
|
|
workingLabelSwitchedPathRemoteDefectIndication ( 7770 ),
|
|
protectLabelSwitchedPathRemoteDefectIndication ( 7775 ),
|
|
bidirectionalForwardDetectionDown ( 7780 ),
|
|
tpTrafficSwitchedFromWorkingToProtection ( 7785 ),
|
|
workingTpLockout ( 7790 ),
|
|
protectTpLockout ( 7795 ),
|
|
ethernetFlowPointFailed ( 7800 ),
|
|
teTunnelDown ( 7805 ),
|
|
macSystemLimitReached ( 7810 ),
|
|
macBridgeDomainLimitReached ( 7815 ),
|
|
autoSensingDisabled ( 7820 ),
|
|
smBackwardIncomingAlignmentError ( 7825 ),
|
|
resourceAllocationFailed ( 7830 ),
|
|
lossOfDFBSignal ( 7835 ),
|
|
workingLabelSwitchedPathLinkDownIndication ( 7840 ),
|
|
protectLabelSwitchedPathLinkDownIndication ( 7845 ),
|
|
workingLabelSwitchedPathLockReport ( 7850 ),
|
|
protectLabelSwitchedPathLockReport ( 7855 ),
|
|
satellitePanelBatteryFailureB ( 7860 ),
|
|
highBitErrorRate (7865),
|
|
backPanelFacilityLoopback (7870),
|
|
backPanelTerminalLoopback (7875),
|
|
trunkPayloadTypeMismatch (7880),
|
|
invalidMuxponderConfiguration (7885),
|
|
coolingProfileMismatch (7890),
|
|
trunkOduAlarmIndicationSignal (7895),
|
|
companionCardMissing (7900),
|
|
controlPlaneUnverifiedClearedAlarmsPresent (7905),
|
|
powerConsumptionLimitHasCrossed (7910),
|
|
masterKeyExchangeFailed (7915),
|
|
unitHighTemperature (7930),
|
|
overTemperatureUnitProtected (7935),
|
|
seqMismatchCount (7945),
|
|
keyProgramOnAlteraFpgaFailed (7960),
|
|
duplicateNodeControllerDetected (7970),
|
|
restorationInProg (7975),
|
|
ramanPumpsCalibrationProcedureIsRunning (7980),
|
|
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes (7985),
|
|
odukTCM1AlarmIndicationSignal ( 13100 ),
|
|
odukTCM2AlarmIndicationSignal ( 13105 ),
|
|
odukLockedDefectTCM1 ( 13110 ),
|
|
odukLockedDefectTCM2 ( 13115 ),
|
|
otukLossOfFrame ( 13120 ),
|
|
odukOpenConnectionIndicationTCM1 ( 13125 ),
|
|
odukOpenConnectionIndicationTCM2 ( 13130 ),
|
|
odukTrailTraceIdentifierMismatchTCM1 ( 13135 ),
|
|
odukTrailTraceIdentifierMismatchTCM2 ( 13140 ),
|
|
odukSignalFailureTCM1 ( 13145 ),
|
|
odukSignalFailureTCM2 ( 13150 ),
|
|
odukSignalDegradeTCM1 ( 13155 ),
|
|
odukSignalDegradeTCM2 ( 13160 ),
|
|
lossOfChannel ( 13165 ),
|
|
fecMismatch ( 13170 ),
|
|
timSectionMonitorTraceIdentifierMismatchFailure ( 13175 ),
|
|
automaticLaserShutdown ( 13180 ),
|
|
shutterInsertionLossVariationDegradeLow ( 13200 ),
|
|
opticalChannelDeactivationFailure ( 13205 ),
|
|
shutterInsertionLossVariationDegradeHigh ( 13210 ),
|
|
networkTopologyIncomplete ( 13215 ),
|
|
pluginModuleCommunicationFailure ( 13220 ),
|
|
opticalNetworkTypeMismatch ( 13225 ),
|
|
opticalPowerDegradeLow ( 13230 ),
|
|
automaticPowerControlFailure ( 13235 ),
|
|
opticalPowerDegradeHigh ( 13240 ),
|
|
automaticPowerControlDisabled ( 13245 ),
|
|
opticalPowerFailureLow ( 13250 ),
|
|
ringIdMismatch ( 13255 ),
|
|
opticalPowerFailureHigh ( 13260 ),
|
|
lossOfContinuity ( 13270 ),
|
|
variableOpticalAttenuatorDegradeLow ( 13280 ),
|
|
variableOpticalAttenuatorDegradeHigh ( 13290 ),
|
|
variableOpticalAttenuatorFailureLow ( 13300 ),
|
|
variableOpticalAttenuatorFailureHigh ( 13310 ),
|
|
laserBiasDegrade ( 13320 ),
|
|
laserBiasFailure ( 13330 ),
|
|
laserTemperatureDegrade ( 13340 ),
|
|
opticalAmplifierGainDegradeLow ( 13350 ),
|
|
opticalAmplifierGainDegradeHigh ( 13360 ),
|
|
opticalAmplifierGainFailureLow ( 13370 ),
|
|
opticalAmplifierGainFailureHigh ( 13380 ),
|
|
opticalChannelConnectionFailure ( 13390 ),
|
|
opticalChannelIncomplete ( 13395 ),
|
|
opticalChannelActivationFailure ( 13400 ),
|
|
laserAutoPowerReduction ( 13410 ),
|
|
caseTemperatureDegrade ( 13420 ),
|
|
fiberTemperatureDegrade ( 13430 ),
|
|
shutterOpen ( 13440 ),
|
|
awgTemperatureDegrade ( 13450 ),
|
|
awgTemperatureFailure ( 13460 ),
|
|
awgOverTemperature ( 13470 ),
|
|
opticalAmplifierInitialization ( 13480 ),
|
|
awgWarmUp ( 13490 ),
|
|
incSigloss ( 13510 ),
|
|
incSyncloss ( 13515 ),
|
|
incGfpOutOfFrame ( 13520 ),
|
|
incGfpSigLoss ( 13525 ),
|
|
incGfpSyncLoss ( 13530 )
|
|
}
|
|
|
|
-- Cerent454ObjectType ::= TEXTUAL-CONVENTION
|
|
-- DISPLAY-HINT "d"
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "Very similar to the alarm type TC, except this is
|
|
-- used for object type display"
|
|
-- SYNTAX INTEGER {
|
|
-- objectNone ( 1 ),
|
|
-- objectEntity ( 10 ),
|
|
-- objectInterface ( 20 ),
|
|
-- objectOspf ( 30 ),
|
|
-- objectProtectionGroup ( 40 ),
|
|
-- objectSdccTerm ( 50 ),
|
|
-- objectSync ( 60 ),
|
|
-- objectSecurity ( 70 ),
|
|
-- objectTopologyElement ( 80 ),
|
|
-- objectSystem ( 90 ),
|
|
-- objectStsConnection ( 100 ),
|
|
-- objectVtConnection ( 110 ),
|
|
-- objectSonetPool ( 120 ),
|
|
-- objectEtherBridge ( 130 ),
|
|
-- objectSpanningTree ( 140 ),
|
|
-- objectVlan ( 150 ),
|
|
-- objectCircuit ( 160 )
|
|
-- }
|
|
|
|
Cerent454EntityClass ::= TEXTUAL-CONVENTION
|
|
-- DISPLAY-HINT "d"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the TC used to find out to which cerent454EntityClass
|
|
an alarm belongs to."
|
|
SYNTAX INTEGER {
|
|
unknownEntity ( 1 ),
|
|
ne ( 10 ),
|
|
backplane ( 30 ),
|
|
eqpt ( 50 ),
|
|
port ( 60 ),
|
|
ocn ( 70 ),
|
|
stmn ( 71 ),
|
|
aip ( 80 ),
|
|
fanTray ( 90 ),
|
|
crs ( 100 ),
|
|
ds3 ( 110 ),
|
|
almExpPanel ( 120 ),
|
|
almIfExtnsn ( 130 ),
|
|
stsMon ( 140 ),
|
|
vcMonHp ( 141 ),
|
|
dwdmClient ( 150 ),
|
|
stsTerm ( 160 ),
|
|
vcTermHp ( 161 ),
|
|
dwdmTrunk ( 170 ),
|
|
dwdmOptics ( 180 ),
|
|
psSts ( 190 ),
|
|
rsms ( 200 ),
|
|
xcSts ( 210 ),
|
|
bits ( 220 ),
|
|
dwdmFec ( 230 ),
|
|
neSynchRef ( 240 ),
|
|
dwdm8b10b ( 250 ),
|
|
extSynchRef ( 260 ),
|
|
dwdmOtn ( 270 ),
|
|
envAlrm ( 280 ),
|
|
envCtrl ( 290 ),
|
|
neRing ( 360 ),
|
|
ds1 ( 390 ),
|
|
vtMon ( 410 ),
|
|
vcMonLp ( 411 ),
|
|
vtTerm ( 420 ),
|
|
vcTermLP ( 421 ),
|
|
fUdc ( 430 ),
|
|
msUdc ( 440 ),
|
|
spareSdcc ( 450 ),
|
|
ucpCircuit ( 480 ),
|
|
ucpIpcc ( 490 ),
|
|
ucpNeighbor ( 500 ),
|
|
ec1 ( 510 ),
|
|
ps ( 520 ),
|
|
psVt ( 530 ),
|
|
e100t ( 540 ),
|
|
e1000t ( 550 ),
|
|
etherBridge ( 560 ),
|
|
e1 ( 600 ),
|
|
e3 ( 630 ),
|
|
e4 ( 640 ),
|
|
stm1E ( 650 ),
|
|
ds3i ( 660 ),
|
|
g1000 ( 670 ),
|
|
ml100t ( 680 ),
|
|
ml1000 ( 690 ),
|
|
dwdmSfp ( 700 ),
|
|
dwdmScl ( 710 ),
|
|
dwdmTcm1 ( 720 ),
|
|
dwdmTcm2 ( 730 ),
|
|
dwdmOcn ( 740 ),
|
|
dwdmSm ( 750 ),
|
|
dwdmPm ( 760 ),
|
|
dwdmTcm ( 770 ),
|
|
pwr ( 780 ),
|
|
stsTermVcat ( 790 ),
|
|
vtTermVcat ( 800 ),
|
|
vcatGroup ( 810 ),
|
|
fcmr ( 820 ),
|
|
entOptics ( 830 ),
|
|
ce100t ( 840 ),
|
|
ppm ( 850 ),
|
|
twor ( 860 ),
|
|
isc ( 870 ),
|
|
escon ( 880 ),
|
|
bic ( 890 ),
|
|
gfp ( 900 ),
|
|
gige ( 910 ),
|
|
pos ( 920 ),
|
|
cap ( 930 ),
|
|
dwdmData ( 940 ),
|
|
logFac ( 950 ),
|
|
ge ( 960 ),
|
|
fc ( 970 ),
|
|
ec1p1 ( 980 ),
|
|
mlFx ( 990 ),
|
|
ochTerm ( 1000 ),
|
|
shelf ( 1010 ),
|
|
ce1000 ( 1020 ),
|
|
cemr ( 1030 ),
|
|
lmp ( 1040 ),
|
|
lmpControlChannel ( 1050 ),
|
|
lmpTeLink ( 1060 ),
|
|
lmpDataLink ( 1070 ),
|
|
rpr ( 1080 ),
|
|
ether ( 1090 ),
|
|
mlmr ( 1100 ),
|
|
otu ( 1110 ),
|
|
aots ( 3200 ),
|
|
ots ( 3210 ),
|
|
oms ( 3220 ),
|
|
och ( 3230 ),
|
|
osc ( 3240 ),
|
|
ochnc ( 3250 ),
|
|
ib ( 3260 ),
|
|
chgrp ( 3270 ),
|
|
hdlc ( 3280 ),
|
|
msISC ( 3290 ),
|
|
ecu ( 3300 ),
|
|
lcdFlash ( 3310 ),
|
|
usb ( 3320 ),
|
|
fe ( 3330 ),
|
|
odu0 ( 3350 ),
|
|
odu1 ( 3360 )
|
|
|
|
}
|
|
|
|
-- **************************************************************
|
|
cerent454Objects OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cerent454 specific objects themselves"
|
|
::= { cerent454Mib 20 }
|
|
|
|
-- **************************************************************
|
|
-- All Cisco OTBU generic objects definitions
|
|
-- These will be available for all Cisco OTBU products. Hence
|
|
-- they are defined once under generic category.
|
|
|
|
cerent454CommonObjectsGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group to combine all the Cisco OTBU common
|
|
objects"
|
|
::= { cerentCommonObjects 10 }
|
|
|
|
cerent454EnableNotification OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system produces
|
|
notifications. A value=FALSE will prevent notifications
|
|
from being sent by this system."
|
|
DEFVAL { true }
|
|
::= { cerent454CommonObjectsGroup 10 }
|
|
|
|
cerent454NodeTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates current local time as reflected by
|
|
the Cisco OTBU equipment. The format this scalar is
|
|
YYYYMMDDhhmmss{S/D}. E.g.,
|
|
20011103133453D means 1:34:53 PM PDT on 03/Nov/2001
|
|
19990614095436S means 9:54:36 AM PST on 14/Jun/1999.
|
|
If the last octet is S then the time is standard time.
|
|
Otherwise it is D to indicate it is daylight saving
|
|
time, if applicable"
|
|
::= { cerent454CommonObjectsGroup 20 }
|
|
|
|
cerent454SentNotifications OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A count of v1+v2 notifications sent out
|
|
by the agent. Resets to zero after
|
|
cold/warm start."
|
|
::= { cerent454CommonObjectsGroup 30 }
|
|
|
|
cerent454LastChangeTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time
|
|
a conceptual row is created or deleted
|
|
in cerent454AlarmTable "
|
|
::= { cerent454CommonObjectsGroup 40 }
|
|
|
|
cerent454MultishelfEnabled OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates whether the system is configured
|
|
in multi-shelf mode or single-shelf mode."
|
|
DEFVAL { false }
|
|
::= { cerent454CommonObjectsGroup 50 }
|
|
|
|
-- **************************************************************
|
|
--
|
|
cerent454GeneralGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cerent454Objects 20 }
|
|
|
|
cerent454SoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the version of software that is
|
|
used in Cisco ONS 15454. E.g., 2.2.03"
|
|
::= { cerent454GeneralGroup 10 }
|
|
|
|
cerent454AlarmGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group that will represent all the
|
|
alarm info in the Cisco ONS 15454 node"
|
|
::= { cerent454Objects 30 }
|
|
|
|
cerent454AlarmCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of active alarms in Cisco ONS 15454.
|
|
This equals the total number of rows in
|
|
cerent454AlarmTable at any time."
|
|
::= { cerent454AlarmGroup 10 }
|
|
|
|
cerent454AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cerent454AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table has all currently raised conditions
|
|
for the network node. A Condition is a fault or
|
|
status detected by hardware or software."
|
|
::= { cerent454AlarmGroup 20 }
|
|
|
|
cerent454AlarmEntry OBJECT-TYPE
|
|
SYNTAX Cerent454AlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row definition for cerent454AlarmTable"
|
|
INDEX { cerent454AlarmIndex, cerent454AlarmType }
|
|
::= { cerent454AlarmTable 1 }
|
|
|
|
Cerent454AlarmEntry ::= SEQUENCE {
|
|
cerent454AlarmIndex Integer32,
|
|
cerent454AlarmObjectType Cerent454EntityClass,
|
|
cerent454AlarmSlotNumber Integer32,
|
|
cerent454AlarmPortNumber CerentPortNumber,
|
|
cerent454AlarmLineNumber Integer32,
|
|
cerent454AlarmObjectIndex Integer32,
|
|
cerent454AlarmType Cerent454AlarmType,
|
|
cerent454AlarmState CerentNotificationClass,
|
|
cerent454AlarmTimeStamp TimeStamp,
|
|
cerent454AlarmObjectName DisplayString,
|
|
cerent454AlarmAdditionalInfo DisplayString,
|
|
cerent454AlarmSeverity CerentAlarmSeverity,
|
|
cerent454AlarmStatus CerentAlarmStatus,
|
|
cerent454AlarmServiceAffecting CerentAlarmServiceAffecting
|
|
}
|
|
|
|
cerent454AlarmIndex OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies each entry in alarm table.
|
|
May not start with one and there may be some
|
|
missing numbers."
|
|
::= { cerent454AlarmEntry 10 }
|
|
|
|
cerent454AlarmObjectType OBJECT-TYPE
|
|
SYNTAX Cerent454EntityClass
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the type
|
|
of the entity which raised this alarm.
|
|
( E.g., DS3, etherBridge, VT-TERM, etc )
|
|
The NMS is expected to use this value
|
|
to decide which table to poll for
|
|
further info about the alarm"
|
|
::= { cerent454AlarmEntry 20 }
|
|
|
|
cerent454AlarmSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the slot
|
|
of the object which raised this alarm.
|
|
If not relevant to the alarm, will be
|
|
zero."
|
|
::= { cerent454AlarmEntry 30 }
|
|
|
|
cerent454AlarmPortNumber OBJECT-TYPE
|
|
SYNTAX CerentPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the port
|
|
of the object which raised this alarm."
|
|
::= { cerent454AlarmEntry 40 }
|
|
|
|
cerent454AlarmLineNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the port
|
|
of the object which raised this alarm.
|
|
If not relevant to the alarm, will be
|
|
zero."
|
|
::= { cerent454AlarmEntry 50 }
|
|
|
|
cerent454AlarmObjectIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Every alarm is raised by an object and
|
|
this object is an entry in a specific
|
|
table. This is the index of the object
|
|
in that table E.g., if the alarm is interface
|
|
related, this index is the index of the
|
|
interface in the interface table."
|
|
::= { cerent454AlarmEntry 60 }
|
|
|
|
cerent454AlarmType OBJECT-TYPE
|
|
SYNTAX Cerent454AlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates what the exact nature of the
|
|
alarm. See the Cerent454AlarmType TC
|
|
for mapping details "
|
|
::= {cerent454AlarmEntry 70 }
|
|
|
|
cerent454AlarmState OBJECT-TYPE
|
|
SYNTAX CerentNotificationClass
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies alarm severity and service
|
|
affecting status ( SA/NSA ). Only
|
|
{minor|major|critical}+{NA|NSA} alarms and
|
|
standing conditions will be represented here.
|
|
|
|
However, this mib object is included in each
|
|
trap dispatched and in the trap this object
|
|
can contain all the possible values of
|
|
CerentNotificationClass type."
|
|
::= { cerent454AlarmEntry 80 }
|
|
|
|
cerent454AlarmTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when this entry was
|
|
created. This is accurate only upto a second."
|
|
::= { cerent454AlarmEntry 90 }
|
|
|
|
cerent454AlarmObjectName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TL1-style user-visible name which uniquely
|
|
identifies an object in the system"
|
|
::= { cerent454AlarmEntry 100 }
|
|
|
|
cerent454AlarmAdditionalInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information for the alarm object.
|
|
In the current version of the MIB, this object
|
|
contains the following information :-
|
|
|
|
a) Provisioned description for alarms of type
|
|
'failureDetectedExternalToTheNE'.
|
|
|
|
This object would be a null string if no
|
|
additional information is specified."
|
|
::= { cerent454AlarmEntry 110 }
|
|
|
|
cerent454AlarmSeverity OBJECT-TYPE
|
|
SYNTAX CerentAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies severity of the alarm
|
|
being sent out."
|
|
|
|
::= { cerent454AlarmEntry 120 }
|
|
|
|
cerent454AlarmStatus OBJECT-TYPE
|
|
SYNTAX CerentAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents if the alarm is currently raised
|
|
or cleared."
|
|
|
|
::= { cerent454AlarmEntry 130 }
|
|
|
|
cerent454AlarmServiceAffecting OBJECT-TYPE
|
|
SYNTAX CerentAlarmServiceAffecting
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the alarm that is being
|
|
sent out is Service Affecting (SA) or Non-
|
|
Service Affecting (NSA)."
|
|
|
|
::= { cerent454AlarmEntry 140 }
|
|
|
|
|
|
cerent454ReportedAlarmCount OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of alarms currently reported against Cisco
|
|
ONS 15454. This equals the number of rows in
|
|
cerent454ReportedAlarmTable."
|
|
::= { cerent454AlarmGroup 30 }
|
|
|
|
|
|
cerent454ReportedAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cerent454ReportedAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table has the list of alarms currently
|
|
reported for the Cisco ONS node. It does not
|
|
include any cleared alarms. The alarms in this
|
|
table are in compliance with Telcordia GR-253.
|
|
This means that if a network problem causes two
|
|
alarms, such a as loss of frame(LOF) and loss of
|
|
signal(LOS), only LOS alarm will be in this table
|
|
because it supersedes and replaces the LOF."
|
|
::= { cerent454AlarmGroup 40 }
|
|
|
|
cerent454ReportedAlarmEntry OBJECT-TYPE
|
|
SYNTAX Cerent454ReportedAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row definition for cerent454ReportedAlarmTable"
|
|
INDEX { cerent454ReportedAlarmIndex, cerent454ReportedAlarmType }
|
|
::= { cerent454ReportedAlarmTable 1 }
|
|
|
|
Cerent454ReportedAlarmEntry ::= SEQUENCE {
|
|
cerent454ReportedAlarmIndex Integer32,
|
|
cerent454ReportedAlarmObjectType Cerent454EntityClass,
|
|
cerent454ReportedAlarmSlotNumber Integer32,
|
|
cerent454ReportedAlarmPortNumber CerentPortNumber,
|
|
cerent454ReportedAlarmObjectIndex Integer32,
|
|
cerent454ReportedAlarmType Cerent454AlarmType,
|
|
cerent454ReportedAlarmTimeStamp TimeStamp,
|
|
cerent454ReportedAlarmObjectName DisplayString,
|
|
cerent454ReportedAlarmAdditionalInfo DisplayString,
|
|
cerent454ReportedAlarmSeverity CerentAlarmSeverity,
|
|
cerent454ReportedAlarmStatus CerentAlarmStatus,
|
|
cerent454ReportedAlarmServiceAffecting CerentAlarmServiceAffecting
|
|
}
|
|
|
|
cerent454ReportedAlarmIndex OBJECT-TYPE
|
|
SYNTAX Integer32 ( 1..2147483647 ) -- all +ve values
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identifies each entry in ReportedAlarm table.
|
|
May not start with one and there may be some
|
|
missing numbers."
|
|
::= { cerent454ReportedAlarmEntry 10 }
|
|
|
|
cerent454ReportedAlarmObjectType OBJECT-TYPE
|
|
SYNTAX Cerent454EntityClass
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate the type
|
|
of the entity which raised this alarm.
|
|
( E.g., DS3, etherBridge, VT-TERM, etc )
|
|
The NMS is expected to use this value
|
|
to decide which table to poll for
|
|
further info about the alarm"
|
|
::= { cerent454ReportedAlarmEntry 20 }
|
|
|
|
cerent454ReportedAlarmSlotNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the slot
|
|
of the object which raised this alarm.
|
|
If not relevant to the alarm, will be
|
|
zero."
|
|
::= { cerent454ReportedAlarmEntry 30 }
|
|
|
|
cerent454ReportedAlarmPortNumber OBJECT-TYPE
|
|
SYNTAX CerentPortNumber
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This will indicate what is the port
|
|
of the object which raised this alarm."
|
|
::= { cerent454ReportedAlarmEntry 40 }
|
|
|
|
cerent454ReportedAlarmObjectIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Every alarm is raised by an object and
|
|
this object is an entry in a specific
|
|
table. This is the index of the object
|
|
in that table E.g., if the alarm is interface
|
|
related, this is the index of the
|
|
interface in the interface table."
|
|
::= { cerent454ReportedAlarmEntry 50 }
|
|
|
|
cerent454ReportedAlarmType OBJECT-TYPE
|
|
SYNTAX Cerent454AlarmType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the exact nature of the
|
|
alarm."
|
|
::= {cerent454ReportedAlarmEntry 60 }
|
|
|
|
cerent454ReportedAlarmTimeStamp OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when this entry was
|
|
created. This is accurate only upto a second."
|
|
::= { cerent454ReportedAlarmEntry 70 }
|
|
|
|
cerent454ReportedAlarmObjectName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TL1-style user-visible name which uniquely
|
|
identifies an object in the system"
|
|
::= { cerent454ReportedAlarmEntry 80 }
|
|
|
|
cerent454ReportedAlarmAdditionalInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Additional information for the alarm object.
|
|
In the current version of the MIB, this object
|
|
contains the following information :-
|
|
|
|
a) Provisioned description for alarms of type
|
|
'failureDetectedExternalToTheNE'.
|
|
|
|
This object would be a null string if no
|
|
additional information is specified."
|
|
::= { cerent454ReportedAlarmEntry 90 }
|
|
|
|
cerent454ReportedAlarmSeverity OBJECT-TYPE
|
|
SYNTAX CerentAlarmSeverity
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies severity of the alarm."
|
|
|
|
::= { cerent454ReportedAlarmEntry 100 }
|
|
|
|
cerent454ReportedAlarmStatus OBJECT-TYPE
|
|
SYNTAX CerentAlarmStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Represents if the alarm is currently raised
|
|
or cleared."
|
|
|
|
::= { cerent454ReportedAlarmEntry 110 }
|
|
|
|
cerent454ReportedAlarmServiceAffecting OBJECT-TYPE
|
|
SYNTAX CerentAlarmServiceAffecting
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies whether the alarm that is being
|
|
sent out is Service Affecting (SA) or Non-
|
|
Service Affecting (NSA)."
|
|
|
|
::= { cerent454ReportedAlarmEntry 120 }
|
|
|
|
|
|
-- All Cisco ONS 15454 Threshold definitions.
|
|
|
|
cerent454ThresholdGroup OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group that will represent all the
|
|
threshold info in the Cisco ONS 15454 node"
|
|
::= { cerent454Objects 40 }
|
|
|
|
cerent454ThresholdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Cerent454ThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table holds all the defined
|
|
Thresholds.
|
|
|
|
This table is currently unimplemented."
|
|
|
|
::= { cerent454ThresholdGroup 10 }
|
|
|
|
cerent454ThresholdEntry OBJECT-TYPE
|
|
SYNTAX Cerent454ThresholdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Row definition for cerent454ThresholdTable"
|
|
INDEX { cerent454ThresholdIndex }
|
|
::= { cerent454ThresholdTable 1 }
|
|
|
|
Cerent454ThresholdEntry ::= SEQUENCE {
|
|
cerent454ThresholdIndex Integer32,
|
|
cerent454ThresholdMonitorType CerentMonitorType,
|
|
cerent454ThresholdLocation CerentLocation,
|
|
cerent454ThresholdPeriod CerentPeriod,
|
|
cerent454ThresholdSetValue Integer32,
|
|
cerent454ThresholdCurrentValue Integer32,
|
|
cerent454ThresholdDetectType INTEGER
|
|
}
|
|
|
|
cerent454ThresholdIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647) -- Same as IfIndex from IF-MIB
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uniquely identifies each entry in Threshold table.
|
|
May not start with one and there will be some
|
|
missing numbers."
|
|
::= { cerent454ThresholdEntry 10 }
|
|
|
|
cerent454ThresholdMonitorType OBJECT-TYPE
|
|
SYNTAX CerentMonitorType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the type of metric monitored."
|
|
::= { cerent454ThresholdEntry 20 }
|
|
|
|
cerent454ThresholdLocation OBJECT-TYPE
|
|
SYNTAX CerentLocation
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This indicates if it near or far end"
|
|
::= { cerent454ThresholdEntry 30 }
|
|
|
|
cerent454ThresholdPeriod OBJECT-TYPE
|
|
SYNTAX CerentPeriod
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sampling interval period is indicated here"
|
|
::= { cerent454ThresholdEntry 40 }
|
|
|
|
cerent454ThresholdSetValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object will be threshold that was
|
|
provisioned by the NMS"
|
|
::= { cerent454ThresholdEntry 50 }
|
|
|
|
-- TEXTUAL CONVENTION
|
|
-- Description
|
|
-- The value of the optical parameter that is being monitored.
|
|
--
|
|
-- The range of values varies depending on the type of optical
|
|
-- parameter being monitored, as identified by a corresponding
|
|
-- object with syntax OpticalParameterType.
|
|
--
|
|
-- when the optical parameter being monitored is 'power' or
|
|
-- 'acpower', the supported range is from -1000 to 1000, in
|
|
-- 1/10ths of dBm.
|
|
-- Example: Actual power of -40 dbm is represented as -400.
|
|
-- Actual power level of +30 dBm is represented as 300.
|
|
--
|
|
-- When the optical parameter being monitored is 'laserTemp' or
|
|
-- 'apdTemp', the supported range is from -10000 to 30000, in
|
|
-- 1/100ths of degrees centigrade.
|
|
-- Example: A value of 2355 represents a temperature reading of
|
|
-- 23.55 degrees C.
|
|
--
|
|
-- When the optical parameter being monitored is 'biasCurrent',
|
|
-- the supported range is from 0 to 1000, in 1/10ths of
|
|
-- percentage (%).
|
|
-- Example: A value of 500 represents a bias current threshold
|
|
-- of 50.0 %.
|
|
--
|
|
-- When the optical parameter being monitored is 'peltierCurrent',
|
|
-- the supported range is from 0 to 10000, in milliamperes.
|
|
--
|
|
-- When the optical parameter being monitored is 'xcvrVoltage',
|
|
-- the supported range is from 0 to 100000, in 1/10ths of
|
|
-- millivolts.
|
|
|
|
cerent454ThresholdCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current value of the counter which
|
|
measures the metric. This column will never be
|
|
implemented as the value of this object is already
|
|
accessible through IETF MIBs."
|
|
::= { cerent454ThresholdEntry 60 }
|
|
|
|
-- TEXTUAL CONVENTION
|
|
-- Description
|
|
-- The value of the optical parameter that is being monitored.
|
|
--
|
|
-- The range of values varies depending on the type of optical
|
|
-- parameter being monitored, as identified by a corresponding
|
|
-- object with syntax OpticalParameterType.
|
|
--
|
|
-- when the optical parameter being monitored is 'power' or
|
|
-- 'acpower', the supported range is from -1000 to 1000, in
|
|
-- 1/10ths of dBm.
|
|
-- Example: Actual power of -40 dbm is represented as -400.
|
|
-- Actual power level of +30 dBm is represented as 300.
|
|
--
|
|
-- When the optical parameter being monitored is 'laserTemp' or
|
|
-- 'apdTemp', the supported range is from -10000 to 30000, in
|
|
-- 1/100ths of degrees centigrade.
|
|
-- Example: A value of 2355 represents a temperature reading of
|
|
-- 23.55 degrees C.
|
|
--
|
|
-- When the optical parameter being monitored is 'biasCurrent',
|
|
-- the supported range is from 0 to 1000, in 1/10ths of
|
|
-- percentage (%).
|
|
-- Example: A value of 500 represents a bias current threshold
|
|
-- of 50.0 %.
|
|
--
|
|
-- When the optical parameter being monitored is 'peltierCurrent',
|
|
-- the supported range is from 0 to 10000, in milliamperes.
|
|
--
|
|
-- When the optical parameter being monitored is 'xcvrVoltage',
|
|
-- the supported range is from 0 to 100000, in 1/10ths of
|
|
-- millivolts.
|
|
|
|
|
|
cerent454ThresholdDetectType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
none(10),
|
|
mon(20),
|
|
term(30)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of this object will be the detect type for the
|
|
threshold."
|
|
::= { cerent454ThresholdEntry 70 }
|
|
|
|
|
|
-- All Cisco ONS 15454 Notifications definitions.
|
|
|
|
cerent454Events OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Place holder for all notifications of Cisco ONS 15454"
|
|
::= { cerent454Mib 30 }
|
|
|
|
cerent454V2Events OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sub-identifier has to be zero, as part
|
|
of the interoperability agreement between
|
|
SNMPv1 and SNMPv2 worlds."
|
|
::= { cerent454Events 0 }
|
|
|
|
-- ---------------------------------------------
|
|
-- All the Cisco ONS 15454 notifications definitions
|
|
-- ---------------------------------------------
|
|
|
|
-- object and event groups
|
|
|
|
alarmUnknown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm unknown"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
|
|
::= { cerent454V2Events 1 }
|
|
|
|
alarmCutoffIsInManualMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm cutoff is in manual mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 10 }
|
|
|
|
failureDetectedExternalToTheNE
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmAdditionalInfo,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure detected External to the NE"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 20 }
|
|
|
|
externalError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "external error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 30 }
|
|
|
|
excessiveSwitching
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "excessive switching"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 40 }
|
|
|
|
sdccTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SDCC Termination failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 50 }
|
|
|
|
incomingFailureCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "incoming failure condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 60 }
|
|
|
|
alarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm indication signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 70 }
|
|
|
|
alarmIndicationSignalLine
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm indication signal LINE"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 80 }
|
|
|
|
alarmIndicationSignalPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm indication signal Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 90 }
|
|
|
|
alarmIndicationSignalVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "alarm indication signal VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 100 }
|
|
|
|
apsChannelFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"APS Channel Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 110 }
|
|
|
|
channelByteFailureAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel Byte failure APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 120 }
|
|
|
|
channelProtectionSwitchingChannelMatchFailureAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel Protection Switching Channel Match failure APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 130 }
|
|
|
|
channelAutomaticProtectionSwitchModeMismatchAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel Automatic Protection Switch Mode Mismatch APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 140 }
|
|
|
|
farEndProtectionLineFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Protection Line Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 150 }
|
|
|
|
inconsistentAPSCode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Inconsistent APS code"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 160 }
|
|
|
|
improperAPSCode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Improper APS code"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 170 }
|
|
|
|
nodeIdMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Node Id Mismatch APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 180 }
|
|
|
|
channelDefaultKAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel Default K APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 190 }
|
|
|
|
connectionLoss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Connection loss APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 200 }
|
|
|
|
bipolarViolation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "bipolar Violation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 210 }
|
|
|
|
carrierLossOnTheLAN
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "carrier Loss on the LAN"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 220 }
|
|
|
|
concatenationErrorSTS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "concatenation error STS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 230 }
|
|
|
|
excessCollisionsOnTheLAN
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "excess collisions on the LAN"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 240 }
|
|
|
|
facilityFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Facility Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 250 }
|
|
|
|
farEndAIS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end AIS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 260 }
|
|
|
|
farEndMultipleDS1LOSDetectedOnDS3
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end Multiple DS1 LOS detected on DS3"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 270 }
|
|
|
|
farEndDS1EqptFailNonServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end DS1 eqpt fail non service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 280 }
|
|
|
|
farEndDS1EqptFailServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end DS1 Eqpt fail service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 290 }
|
|
|
|
farEndSingleDS1LOS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end Single DS1 LOS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 300 }
|
|
|
|
farEndDS3EqptFailNonServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end DS3 Eqpt failure non service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 310 }
|
|
|
|
farEndDS3EqptFailServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end DS3 Eqpt failure service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 320 }
|
|
|
|
farEndCommonEquipmentFailureNonServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end common Eqpt failure non service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 330 }
|
|
|
|
farEndIDLE
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end IDLE"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 340 }
|
|
|
|
farEndLOS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end LOS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 350 }
|
|
|
|
farEndLOF
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end LOF"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 360 }
|
|
|
|
farEndBlockError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far End Block Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 370 }
|
|
|
|
ds3IdleCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "idle Condition DS3"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 380 }
|
|
|
|
lossOfFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss of Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 390 }
|
|
|
|
lossOfPointer
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss of Pointer"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 400 }
|
|
|
|
lossOfPointerPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss of Pointer Path "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 410 }
|
|
|
|
lossOfPointerVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss of Pointer VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 420 }
|
|
|
|
lossOfSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss of Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 430 }
|
|
|
|
outOfFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "out of Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 440 }
|
|
|
|
pathSelectorFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Path Selector Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 450 }
|
|
|
|
remoteAlarmIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Alarm Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 460 }
|
|
|
|
remoteFailureIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Failure Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 470 }
|
|
|
|
remoteFailureIndicationLine
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Failure Indication LINE"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 480 }
|
|
|
|
remoteFailureIndicationPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Failure Indication Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 490 }
|
|
|
|
remoteFailureIndicationVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Failure Indication VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 500 }
|
|
|
|
signalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "facility has passed BER Threshold for Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 510 }
|
|
|
|
severelyErroredFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "severely Errored Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 520 }
|
|
|
|
signalFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "facility has passed BER threshold for Signal Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 530 }
|
|
|
|
signalLabelMismatchFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "signal Label Mismatch Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 540 }
|
|
|
|
payloadDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 550 }
|
|
|
|
payloadDefectIndicationPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Defect Indication - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 560 }
|
|
|
|
payloadLabelMismatchPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Label Mismatch - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 570 }
|
|
|
|
signalLabelMismatchFailurePayloadLabelMismatchVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "signal Label Mismatch Failure Payload Label Mismatch VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 580 }
|
|
|
|
unequippedPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unequipped - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 590 }
|
|
|
|
signalLabelMismatchFailureUnequippedVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "signal Label Mismatch Failure Unequipped VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 600 }
|
|
|
|
lossOfSynchronization
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Synchronization"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 610 }
|
|
|
|
outOfSynchronization
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Out of Synchronization"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 620 }
|
|
|
|
primarySynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Primary Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 630 }
|
|
|
|
secondarySynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Secondary Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 640 }
|
|
|
|
thirdSynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Third Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 650 }
|
|
|
|
fourthSynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fourth Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 660 }
|
|
|
|
fifthSynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fifth Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 670 }
|
|
|
|
sixthSynchronizationReferenceFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Sixth Synchronization Reference Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 680 }
|
|
|
|
failedToReceiveSynchronizationStatusMessage
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failed to receive Synchronization Status Message"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 690 }
|
|
|
|
synchronizationStatusMessagesAreDisabledOnThisInterface
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "synchronization Status Messages are disabled on this
|
|
interface"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 700 }
|
|
|
|
stratum1PrimaryReferenceSourceTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Stratum1 Primary Reference Source Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 710 }
|
|
|
|
synchronizedTraceabilityUnknown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "synchronized Traceability Unknown"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 720 }
|
|
|
|
stratum2Traceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "stratum 2 Traceable "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 730 }
|
|
|
|
transitNodeClockTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "transit Node clock Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 740 }
|
|
|
|
stratum3ETraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "stratum 3E Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 750 }
|
|
|
|
stratum3Traceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "stratum 3 Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 760 }
|
|
|
|
sonetMinimumClockTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SONET Minimum Clock Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 770 }
|
|
|
|
stratum4Traceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "stratum 4 Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 780 }
|
|
|
|
doNotUseForSynchronization
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "do not Use for Synchronization"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 790 }
|
|
|
|
reservedForNetworkSynchronizationUse
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "reserved for Network Synchronization Use"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 800 }
|
|
|
|
outgoingFailureCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "outgoing failure condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 810 }
|
|
|
|
remoteDefectIndicationLine
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Defect Indication LINE"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 820 }
|
|
|
|
remoteDefectIndicationPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "remote Defect Indication Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 830 }
|
|
|
|
freeRunningSynchronizationMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "free Running Synchronization mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 840 }
|
|
|
|
holdoverSynchronizationMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "holdover synchronization mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 850 }
|
|
|
|
fastStartSynchronizationMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "fast Start synchronization mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 860 }
|
|
|
|
internalFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 870 }
|
|
|
|
internalError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internal Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 880 }
|
|
|
|
internalMessageError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "internal Message Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 890 }
|
|
|
|
mismatchOfEquipmentAndAttributes
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "mismatch of Equipment and Attributes"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 900 }
|
|
|
|
watchdogTimerTimeout
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "watchdog Timer Timeout"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 910 }
|
|
|
|
softwareFaultOrFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "software Fault or failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 920 }
|
|
|
|
softwareFaultDataIntegrityFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "software Fault - Data integrity fault :
|
|
The newly added provisioning or hardware has
|
|
caused the database to grow beyond its limit.
|
|
That is, the newly added object(s) in the system
|
|
has(have) enough memory to exist onboard but
|
|
too large to be saved in the database."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 930 }
|
|
|
|
programFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "program failure "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 940 }
|
|
|
|
controlEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "control Equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 950 }
|
|
|
|
primaryNonVolatileBackupMemoryFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Primary Non-Volatile Backup Memory Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 960 }
|
|
|
|
secondaryNonVolatileBackupMemoryFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secondary Non-Volatile Backup Memory Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 970 }
|
|
|
|
controlBusFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control Bus Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 980 }
|
|
|
|
controlBus1Failure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control Bus 1 Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 990 }
|
|
|
|
controlBus2Failure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control Bus 2 Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1000 }
|
|
|
|
tccAToShelfSlot1DROP1CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 1 (DROP 1) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1010 }
|
|
|
|
tccAToShelfSlot2DROP2CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 2 (DROP 2) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1020 }
|
|
|
|
tccAToShelfSlot3DROP3CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 3 (DROP 3) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1030 }
|
|
|
|
tccAToShelfSlot4DROP4CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 4 (DROP 4) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1040 }
|
|
|
|
tccAToShelfSlot5TRUNK1CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 5 (TRUNK 1) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1050 }
|
|
|
|
tccAToShelfSlot6TRUNK2CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 6 (TRUNK 2) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1060 }
|
|
|
|
tccAToShelfSlot7TCCACommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 7 (TCC A) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1070 }
|
|
|
|
tccAToShelfSlot8XCONACommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 8 (XCON A) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1080 }
|
|
|
|
tccAToShelfSlot9AICCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 9 (AIC) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1090 }
|
|
|
|
tccAToShelfSlot10XCONBCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 10 (XCON B) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1100 }
|
|
|
|
tccAToShelfSlot11TCCBCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 11 (TCC B) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1110 }
|
|
|
|
tccAToShelfSlot12TRUNK3CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 12 (TRUNK 3) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1120 }
|
|
|
|
tccAToShelfSlot13TRUNK4CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 13 (TRUNK 4) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1130 }
|
|
|
|
tccAToShelfSlot14DROP5CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 14 (DROP 5) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1140 }
|
|
|
|
tccAToShelfSlot15DROP6CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 15 (DROP 6) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1150 }
|
|
|
|
tccAToShelfSlot16DROP7CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 16 (DROP 7) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1160 }
|
|
|
|
tccAToShelfSlot17DROP8CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC A To Shelf Slot 17 (DROP 8) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1170 }
|
|
|
|
tccAToDCCAProcessorCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "communication failure TCC A to DCC A processor"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1180 }
|
|
|
|
tccBToShelfSlot1DROP1CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 1 (DROP 1) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1190 }
|
|
|
|
tccBToShelfSlot2DROP2CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 2 (DROP 2) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1200 }
|
|
|
|
tccBToShelfSlot3DROP3CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 3 (DROP 3) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1210 }
|
|
|
|
tccBToShelfSlot4DROP4CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 4 (DROP 4) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1220 }
|
|
|
|
tccBToShelfSlot5TRUNK1CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 5 (TRUNK 1) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1230 }
|
|
|
|
tccBToShelfSlot6TRUNK2CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 6 (TRUNK 2) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1240 }
|
|
|
|
tccBToShelfSlot7TCCACommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 7 (TCC A) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1250 }
|
|
|
|
tccBToShelfSlot8XCONACommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 8 (XCON A) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1260 }
|
|
|
|
tccBToShelfSlot9AICCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 9 (AIC) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1270 }
|
|
|
|
tccBToShelfSlot10XCONBCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 10 (XCON B) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1280 }
|
|
|
|
tccBToShelfSlot11TCCBCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 11 (TCC B) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1290 }
|
|
|
|
tccBToShelfSlot12TRUNK3CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 12 (TRUNK 3) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1300 }
|
|
|
|
tccBToShelfSlot13TRUNK4CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 13 (TRUNK 4) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1310 }
|
|
|
|
tccBToShelfSlot14DROP5CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 14 (DROP 5) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1320 }
|
|
|
|
tccBToShelfSlot15DROP6CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 15 (DROP 6) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1330 }
|
|
|
|
tccBToShelfSlot16DROP7CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 16 (DROP 7) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1340 }
|
|
|
|
tccBToShelfSlot17DROP8CommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To Shelf Slot 17 (DROP 8) Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1350 }
|
|
|
|
tccBToDCCBProcessorCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TCC B To DCC B Processor Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1360 }
|
|
|
|
controlEquipmentControlCommunicationsEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "control Equipment Control Communications equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1370 }
|
|
|
|
controlProcessorFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control Processor Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1380 }
|
|
|
|
workingMemoryFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Working Memory Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1390 }
|
|
|
|
interconnectionEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "interconnection Equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1400 }
|
|
|
|
payloadBusFailureToIOSlot1XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 1 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1410 }
|
|
|
|
payloadBusFailureToIOSlot2XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 2 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1420 }
|
|
|
|
payloadBusFailureToIOSlot3XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 3 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1430 }
|
|
|
|
payloadBusFailureToIOSlot4XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 4 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1440 }
|
|
|
|
payloadBusFailureToIOSlot5XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 5 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1450 }
|
|
|
|
payloadBusFailureToIOSlot6XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 6 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1460 }
|
|
|
|
payloadBusFailureToIOSlot12XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 12 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1470 }
|
|
|
|
payloadBusFailureToIOSlot13XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 13 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1480 }
|
|
|
|
payloadBusFailureToIOSlot14XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 14 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1490 }
|
|
|
|
payloadBusFailureToIOSlot15XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 15 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1500 }
|
|
|
|
payloadBusFailureToIOSlot16XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 16 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1510 }
|
|
|
|
payloadBusFailureToIOSlot17XCONSlot8
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 17 (XCON Slot 8)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1520 }
|
|
|
|
payloadBusFailureToIOSlot1XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 1 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1530 }
|
|
|
|
payloadBusFailureToIOSlot2XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 2 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1540 }
|
|
|
|
payloadBusFailureToIOSlot3XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 3 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1550 }
|
|
|
|
payloadBusFailureToIOSlot4XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 4 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1560 }
|
|
|
|
payloadBusFailureToIOSlot5XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 5 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1570 }
|
|
|
|
payloadBusFailureToIOSlot6XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 6 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1580 }
|
|
|
|
payloadBusFailureToIOSlot12XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 12 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1590 }
|
|
|
|
payloadBusFailureToIOSlot13XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 13 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1600 }
|
|
|
|
payloadBusFailureToIOSlot14XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 14 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1610 }
|
|
|
|
payloadBusFailureToIOSlot15XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 15 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1620 }
|
|
|
|
payloadBusFailureToIOSlot16XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 16 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1630 }
|
|
|
|
payloadBusFailureToIOSlot17XCONSlot10
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Payload Bus Failure To IO Slot 17 (XCON Slot 10)"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1640 }
|
|
|
|
timeSlotInterchangeEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time Slot Interchange Equipment Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1650 }
|
|
|
|
equipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1660 }
|
|
|
|
highTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1670 }
|
|
|
|
invalidMACAddress
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Invalid MAC Address"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1680 }
|
|
|
|
boardFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Board Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1690 }
|
|
|
|
diagnosticFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "equipment failure Diagnostics Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1700 }
|
|
|
|
mediumAccessControlFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Medium Access Control Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1710 }
|
|
|
|
facilityTerminationEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "facility Termination equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1720 }
|
|
|
|
automaticLaserShutoffDueToHighTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Laser Shutoff Due To High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1730 }
|
|
|
|
failureToReleaseFromProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure To Release from protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1740 }
|
|
|
|
receiverFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receiver Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1750 }
|
|
|
|
transmitFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1760 }
|
|
|
|
facilityTerminationEquipmentReceiverMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "facility Termination equipment Receiver missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1770 }
|
|
|
|
facilityTerminationEquipmentTransmitterMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "facility Termination equipment Transmitter missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1780 }
|
|
|
|
failureToSwitchToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure To Switch to protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1790 }
|
|
|
|
failureToSwitchToProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure To Switch to protection Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1800 }
|
|
|
|
failureToSwitchToProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure To Switch to protection Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1810 }
|
|
|
|
failureToSwitchToProtectionPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "failure to Switch to protection Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1820 }
|
|
|
|
fanFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fan Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1830 }
|
|
|
|
equipmentUnitPlugIn
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "equipment unit plug in"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1840 }
|
|
|
|
nePowerFailureAtConnector
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "NE Power Failure At Connector"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1850 }
|
|
|
|
fuseAlarm
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fuse Alarm"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1860 }
|
|
|
|
synchronizationUnitFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "synchronization unit failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1870 }
|
|
|
|
synchronizationSwitchingEquipmentFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "synchronization switching Equipment failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1880 }
|
|
|
|
equipmentUnitUnplugged
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Equipment Unit Un-plugged"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1890 }
|
|
|
|
loopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loop back"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1900 }
|
|
|
|
ds1LoopbackDueToFEACCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DS1 Loopback Due To FEAC Command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1910 }
|
|
|
|
loopbackCommandSentToFarEndDS1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loopback Command sent to Far End DS1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1920 }
|
|
|
|
ds3LoopbackDueToFEACCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loopback due to FEAC command DS3"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1930 }
|
|
|
|
ds3LoopbackCommandSentToFarEnd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DS3 Loopback Command Sent To Far End"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1940 }
|
|
|
|
ds2LoopbackDueToFarEndCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DS2 Loopback Due To Far End Command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1950 }
|
|
|
|
ds2LoopbackCommandSentToFarEnd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DS2 Loopback Command Sent To Far End"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1960 }
|
|
|
|
facilityLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Facility Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1970 }
|
|
|
|
networkLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1980 }
|
|
|
|
terminalLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Terminal Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 1990 }
|
|
|
|
manuallyCausedAbnormalCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "manually caused abnormal condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2000 }
|
|
|
|
ethernetBridgeIsNewRootOfSpanningTree
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet Bridge Is New Root Of Spanning Tree"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2010 }
|
|
|
|
ethernetBridgeTopologyChange
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet Bridge Topology Change"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2020 }
|
|
|
|
normalCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "normal condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2030 }
|
|
|
|
embeddedOperationsChannelFailureLinkDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "embedded Operations Channel failure link down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2040 }
|
|
|
|
peerStateMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "peer state mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2050 }
|
|
|
|
proceduralError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "procedural Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2060 }
|
|
|
|
improperRemoval
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Improper Removal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2070 }
|
|
|
|
duplicateNodeID
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Duplicate Node ID"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2080 }
|
|
|
|
blsrOutOfSync
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BLSR out of sync"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2090 }
|
|
|
|
blsrMultiNodeTableUpdateCompleted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BLSR Multi-Node Table Update Completed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2100 }
|
|
|
|
protectionUnitNotAvailable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "protection unit not available"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2110 }
|
|
|
|
performanceMonitorThresholdCrossingAlert
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454ThresholdMonitorType,
|
|
cerent454ThresholdLocation,
|
|
cerent454ThresholdPeriod,
|
|
cerent454ThresholdSetValue,
|
|
cerent454ThresholdCurrentValue,
|
|
cerent454ThresholdDetectType,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "performance Monitor Threshold Crossing Alert"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2120 }
|
|
|
|
protectionSwitch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Protection Switch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2130 }
|
|
|
|
recoveryOrServiceProtectionActionHasBeenInitiated
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "recovery or service protection action has been initiated"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2140 }
|
|
|
|
automaticSystemReset
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic system Reset"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2150 }
|
|
|
|
automaticUPSRSwitchCausedByAIS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic UPSR switch caused by AIS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2160 }
|
|
|
|
automaticUPSRSwitchCausedByLOP
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic UPSR switch caused by Lop"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2170 }
|
|
|
|
automaticUPSRSwitchCausedByUNEQ
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic UPSR Switch Caused By UNEQ"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2180 }
|
|
|
|
automaticUPSRSwitchCausedByPDI
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic UPSR switch caused by PDI"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2190 }
|
|
|
|
automaticUPSRSwitchCausedBySFBER
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic UPSR Switch Caused By SFBER"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2200 }
|
|
|
|
automaticUPSRSwitchCausedBySDBER
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic UPSR Switch Caused By SDBER"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2210 }
|
|
|
|
coldRestart
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "cold Restart"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2220 }
|
|
|
|
forcedSwitchBackToWorking
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch Back To Working"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2230 }
|
|
|
|
forcedSwitchBackToWorkingRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch Back To Working - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2240 }
|
|
|
|
forcedSwitchBackToWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch Back To Working - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2250 }
|
|
|
|
forcedSwitchToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch To Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2260 }
|
|
|
|
forcedSwitchToProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch To Protection - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2270 }
|
|
|
|
forcedSwitchToProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch To Protection - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2280 }
|
|
|
|
workingFacilityOrEquipmentForcedToSwitchToProtectionPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Working Facility or Equipment Forced To Switch To Protection - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2290 }
|
|
|
|
initializationInitiated
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "initialization initiated"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2300 }
|
|
|
|
lockoutOfProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2310 }
|
|
|
|
lockoutOfProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of Protection Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2320 }
|
|
|
|
lockoutOfProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of Protection Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2330 }
|
|
|
|
lockoutOfProtectionPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of Protection Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2340 }
|
|
|
|
lockoutOfWorking
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of working"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2350 }
|
|
|
|
lockoutOfWorkingRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of working Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2360 }
|
|
|
|
lockoutOfWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "lockout of working Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2370 }
|
|
|
|
manualSystemReset
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "manual system Reset"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2380 }
|
|
|
|
manualSwitchToInternalClock
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch to Internal Clock"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2390 }
|
|
|
|
manualSwitchToPrimaryReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Primary Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2400 }
|
|
|
|
manualSwitchToSecondReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Second Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2410 }
|
|
|
|
manualSwitchToThirdReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Third reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2420 }
|
|
|
|
manualSwitchToFourthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Fourth reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2430 }
|
|
|
|
manualSwitchToFifthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Fifth reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2440 }
|
|
|
|
manualSwitchToSixthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Sixth reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2450 }
|
|
|
|
manualSwitchBackToWorking
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch Back To Working"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2460 }
|
|
|
|
manualSwitchBackToWorkingRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch Back To Working - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2470 }
|
|
|
|
manualSwitchBackToWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch Back To Working - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2480 }
|
|
|
|
manualSwitchToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch To Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2490 }
|
|
|
|
manualSwitchToProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch To Protection - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2500 }
|
|
|
|
manualSwitchToProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch To Protection - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2510 }
|
|
|
|
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manual Switch Of Working Facility or Equipment To Protection - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2520 }
|
|
|
|
powerfailRestart
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Powerfail Restart"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2530 }
|
|
|
|
ringIsSquelchingTraffic
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ring is squelching traffic"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2540 }
|
|
|
|
softwareDownloadInProgress
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "software download in progress"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2550 }
|
|
|
|
switchToInternalClock
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Internal clock"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2560 }
|
|
|
|
switchToPrimaryReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Primary refernce"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2570 }
|
|
|
|
switchToSecondReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Switch To Second Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2580 }
|
|
|
|
switchToThirdReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Third refernce"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2590 }
|
|
|
|
switchToFourthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Fourth refernce"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2600 }
|
|
|
|
switchToFifthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Fifth refernce"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2610 }
|
|
|
|
switchToSixthReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switch To Sixth refernce"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2620 }
|
|
|
|
systemReboot
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "system reboot"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2630 }
|
|
|
|
switchedBackToWorking
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switched Back To Working"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2640 }
|
|
|
|
switchedToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switched To Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2650 }
|
|
|
|
warmRestart
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "warm Restart"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2660 }
|
|
|
|
ringIsInWaitToRestoreState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring is in Wait To Restore state"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2670 }
|
|
|
|
manualSwitchRequest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch Request"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2680 }
|
|
|
|
forcedSwitchRequest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch Request"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2690 }
|
|
|
|
lockoutSwitchRequest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Lockout Switch Request"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2700 }
|
|
|
|
rmonHistoriesAndAlarmsResetReboot
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RMON Histories And Alarms Reset Reboot"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2710 }
|
|
|
|
rmonThresholdCrossingAlarm
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Crossing of Falling/Rising Threshold detected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2720 }
|
|
|
|
alarmsSuppressedByUserCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Alarms Suppressed By User Command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2730 }
|
|
|
|
alarmsSuppressedForMaintenance
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Alarms Suppressed For Maintenance"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2740 }
|
|
|
|
switchingMatrixModuleFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switching Matrix Module Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2750 }
|
|
|
|
lanConnectionPolarityReversed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Lan Connection Polarity Reversed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2760 }
|
|
|
|
autonomousPMReportMessageInhibited
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Autonomous PM Report Message Inhibited"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2780 }
|
|
|
|
ioSlotToXCONCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "IO Slot To XCON Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2790 }
|
|
|
|
stsPathTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "STS Path Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2800 }
|
|
|
|
nePowerFailureAtConnectorA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE Power Failure At Connector A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2810 }
|
|
|
|
nePowerFailureAtConnectorB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NE Power Failure At Connector B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2820 }
|
|
|
|
freeMemoryOnCardVeryLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Free memory on the card is very low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2830 }
|
|
|
|
freeMemoryOnCardNearZero
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Free memory on the card is near zero"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2840 }
|
|
|
|
exerciseRequestOnRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exercise Request on Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2850 }
|
|
|
|
exerciseRequestOnSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exercise Request on Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2860 }
|
|
|
|
squelchingPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Squelching Path"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2870 }
|
|
|
|
extraTrafficPreempted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extra Traffic Preempted."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2880 }
|
|
|
|
farEndLockoutOfWorkingRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Lockout of working - Ring."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2890 }
|
|
|
|
farEndLockoutOfWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Lockout of working - Span."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2900 }
|
|
|
|
farEndLockoutOfProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Lockout of Protection - Ring."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2910 }
|
|
|
|
farEndLockoutOfProtectionAllSpans
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Lockout of Protection - All Spans."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2920 }
|
|
|
|
farEndWorkingFacilityForcedToSwitchToProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Working Facility Forced To Switch To Protection - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2930 }
|
|
|
|
|
|
farEndWorkingFacilityForcedToSwitchToProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Working Facility Forced To Switch To Protection - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2940 }
|
|
|
|
farEndManualSwitchOfWorkingFacilityToProtectionRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Manual Switch Of Working Facility To Protection - Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2950 }
|
|
|
|
farEndManualSwitchOfWorkingFacilityToProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Manual Switch Of Working Facility To Protection - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2960 }
|
|
|
|
farEndExercisingRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Exercising Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2970 }
|
|
|
|
farEndExercisingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Exercising Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2980 }
|
|
|
|
farEndBERThresholdPassedForSignalFailureRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End BER threshold passed for Signal Failure - Ring."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 2990 }
|
|
|
|
farEndBERThresholdPassedForSignalFailureSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End BER threshold passed for Signal Failure - Span."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3000 }
|
|
|
|
farEndBERThresholdPassedForSignalDegradeRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End BER threshold passed for Signal Degrade - Ring."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3010 }
|
|
|
|
farEndBERThresholdPassedForSignalDegradeSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End BER threshold passed for Signal Degrade - Span."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3020 }
|
|
|
|
apsChannelFarEndProtectionLineSignalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"APS Channel - Far End Protection Line Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3030 }
|
|
|
|
ringSwitchIsActiveOnTheEastSide
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring Switch is active on the East Side."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3040 }
|
|
|
|
|
|
ringSwitchIsActiveOnTheWestSide
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring Switch is active on the West Side."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3050 }
|
|
|
|
spanSwitchIsActiveOnTheEastSide
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Span Switch is active on the East Side."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3060 }
|
|
|
|
spanSwitchIsActiveOnTheWestSide
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Span Switch is active on the West Side."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3070 }
|
|
|
|
uniDirectionalFullPassThroughIsActive
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Uni-directional Full Pass Through is active."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3080 }
|
|
|
|
|
|
biDirectionalFullPassThroughIsActive
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Bi-directional Full Pass Through is active."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3090 }
|
|
|
|
kBytesPassThroughIsActive
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"K Bytes Pass Through Is Active"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3100 }
|
|
|
|
ringIsSegmented
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring is Segmented."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3110 }
|
|
|
|
ringTopologyIsUnderConstruction
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring Topology is under construction."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3120 }
|
|
|
|
lockoutOfProtectionAllSpans
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Lockout of Protection - All Spans."
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3130 }
|
|
|
|
farEndOfFiberIsProvisionedWithDifferentRingID
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far end of fiber is provisioned with different ring ID"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3140 }
|
|
|
|
bothEndsOfFiberProvisionedAsEastOrBothAsWest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Both ends of fiber provisioned as East, or both as West"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3150 }
|
|
|
|
securityInvalidLoginUsernameSeeAuditTrail
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION "Security: invalid login (see Audit Trail)"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3160 }
|
|
|
|
autonomousMessagesInhibited
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Autonomous messages inhibited"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3170 }
|
|
|
|
trafficStormOnLANLANTemporarilyDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Traffic Storm On LAN. LAN Temporarily Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3180 }
|
|
|
|
reptdbchgMessagesInhibited
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"REPT^DBCHG Messages Inhibited"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3190 }
|
|
|
|
securityUserIDHasExpired
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security: User ID Has Expired"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3200 }
|
|
|
|
partialFanFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Partial Fan Failure"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3210 }
|
|
|
|
forcedSwitchRequestOnRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch Request On Ring"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3220 }
|
|
|
|
forcedSwitchRequestOnSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch Request On Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3230 }
|
|
|
|
lockoutSwitchRequestOnRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Lockout switch request on Ring"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3240 }
|
|
|
|
lockoutSwitchRequestOnSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Lockout switch request on Span"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3250 }
|
|
|
|
manualSwitchRequestOnRing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual switch request on Ring"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3260 }
|
|
|
|
manualSwitchRequestOnSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual switch request on Span"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3270 }
|
|
|
|
communicationFailurePeerToPeerSlotControlBusA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Peer to Peer Slot communication failure - Control Bus A"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3280 }
|
|
|
|
communicationFailurePeerToPeerSlotControlBusB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Peer to Peer Slot communication failure - Control Bus B"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3290 }
|
|
|
|
controllerAToShelfSlotCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Controller A to shelf slot communication failure"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3300 }
|
|
|
|
controllerBToShelfSlotCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Controller B to shelf slot communication failure"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3310 }
|
|
|
|
interconnectionEquipmentFailureWorkingPayloadBus
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Interconnection Equipment Failure - Working Payload Bus"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3320 }
|
|
|
|
interconnectionEquipmentFailureProtectPayloadBus
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Interconnection Equipment Failure - Protect Payload Bus"
|
|
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3330 }
|
|
|
|
inhibitSwitchToProtectRequestOnEquipment
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Inhibit Switch to Protect Request on equipment"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3340 }
|
|
|
|
inhibitSwitchToWorkingRequestOnEquipment
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Inhibit Switch to Working Request on equipment"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3350 }
|
|
|
|
berThresholdExceededForSignalDegradeLine
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BER Threshold exceeded for Signal Degrade - Line"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3360 }
|
|
|
|
berThresholdExceededForSignalDegradePath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BER Threshold exceeded for Signal Degrade - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3370 }
|
|
|
|
berThresholdExceededForSignalFailureLine
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BER Threshold Exceeded For Signal Failure - Line"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3380 }
|
|
|
|
berThresholdExceededForSignalFailurePath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BER Threshold Exceeded For Signal Failure - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3390 }
|
|
|
|
exercisingRingSuccessfully
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exercising Ring Successfully"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3400}
|
|
|
|
exercisingSpanSuccessfully
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Exercising Span Successfully"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3410}
|
|
|
|
spanIsInWaitToRestoreState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Span is in Wait To Restore state"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3420 }
|
|
|
|
exerciseRequestOnRingFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exercise Request on Ring Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3430 }
|
|
|
|
exerciseRequestOnSpanFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Exercise Request on Span Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3440 }
|
|
|
|
farEndLockoutOfProtectionSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Far End Lockout Of Protection - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3450 }
|
|
|
|
manufacturingDataMemoryEEPROMFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manufacturing Data Memory (EEPROM) Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3460 }
|
|
|
|
replaceableEquipmentOrUnitIsMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Replaceable Equipment/Unit is Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3470 }
|
|
|
|
softwareDownloadFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Software Download Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3480 }
|
|
|
|
extraTrafficPCADropped
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Extra Traffic (PCA) Dropped"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3490 }
|
|
|
|
etherTxOversubscribed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ether tx oversubscribed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3500 }
|
|
|
|
etherRxOverSubscribed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ether rx over subscribed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3510 }
|
|
|
|
etherTxExcessFlowCtrl
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ether tx excess flow ctrl"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3520 }
|
|
|
|
etherRxExcessFlowCtrl
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ether rx excess flow ctrl"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3530 }
|
|
|
|
transportLayerFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "transport layer failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3540 }
|
|
|
|
etherTxUnderrun
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ether tx underrun"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3550 }
|
|
|
|
synchronizationReferenceFrequencyOutOfBounds
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Synchronization reference frequency out of bounds."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3560 }
|
|
|
|
ntpOrSntpHostFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "NTP/SNTP Host Failure."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3570 }
|
|
|
|
peerCardNotResponding
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Peer Card Not Responding"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3580 }
|
|
|
|
alarmsAndEventsSuppressedForThisObject
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Alarms and events suppressed for this object"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3590 }
|
|
|
|
ds3FrameFormatMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DS3 Frame Format Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3600 }
|
|
|
|
waitToRestore
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Wait To Restore"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3610 }
|
|
|
|
extremeHighVoltBatteryA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme High Volt Battery A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3620 }
|
|
|
|
extremeLowVoltBatteryA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme Low Volt Battery A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3630 }
|
|
|
|
extremeHighVoltBatteryB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme High Volt Battery B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3640 }
|
|
|
|
extremeLowVoltBatteryB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme Low Volt Battery B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3650 }
|
|
|
|
iosConfigCopyFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "IOS config copy failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3660 }
|
|
|
|
iosConfigCopyInProgress
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "IOS config copy in progress"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3670 }
|
|
|
|
iosConfigCopySuccess
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "IOS Config Copy Success"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3680 }
|
|
|
|
-- Begin: UCP traps
|
|
|
|
signalingUnableToSetupCircuit
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Signaling Unable to setup circuit"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3710 }
|
|
|
|
errorInStartupConfig
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Error in Startup Config"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3712 }
|
|
|
|
noStartupConfig
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "No Startup Config"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3714 }
|
|
|
|
needToSaveRunningConfig
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Need to Save Running Config"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3716 }
|
|
|
|
invalidAlarm
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Invalid Alarm"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3718 }
|
|
|
|
rsvpHelloFSMToNeighborDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RSVP Hello FSM to Neighbor down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3720 }
|
|
|
|
securityInvalidLoginUsername
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security: Invalid Login - Username - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3722 }
|
|
|
|
databaseBackupFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Database Backup Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3724 }
|
|
|
|
databaseRestoreFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Database Restore Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3726 }
|
|
|
|
lmpHelloFSMToControlChannelDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LMP Hello FSM to Control Channel down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3730 }
|
|
|
|
lmpNeighborDiscoveryHasFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LMP Neighbor Discovery has failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3740 }
|
|
|
|
unauthorizedIncomingSignalingRequest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unauthorized incoming signaling request"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3750 }
|
|
|
|
auditLog80PercentFull
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Audit Log 80 Percent Full"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3760 }
|
|
|
|
moduleCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Module Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3762 }
|
|
|
|
auditLog100PercentFullOldestRecordsWillBeLost
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Audit Log 100 Percent Full - Oldest records will be lost"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3764 }
|
|
|
|
standbyDatabaseOutOfSync
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Standby Database Out of Sync"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3766 }
|
|
|
|
redundantPowerCapabilityLost
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Redundant Power Capability Lost"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3768 }
|
|
|
|
-- End: UCP traps
|
|
|
|
forcedSwitchToPrimaryReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch To Primary Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3770 }
|
|
|
|
forcedSwitchToSecondReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch To Second Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3780 }
|
|
|
|
forcedSwitchToThirdReference
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch To Third Reference"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3790 }
|
|
|
|
forcedSwitchToInternalClock
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch To Internal Clock"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3800 }
|
|
|
|
industrialHighTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Industrial High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 3805 }
|
|
|
|
|
|
-- Begin: SDH Traps
|
|
|
|
timSectionTraceIdentifierMismatchFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "TIM Section - Trace Identifier Mismatch Failure."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4000 }
|
|
|
|
aisMultiplexSectionAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AIS - Multiplex Section - Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4010 }
|
|
|
|
rdiMultiplexSectionRemoteDefectOrAlarmIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RDI - Multiplex Section - Remote Defect/Alarm Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4020 }
|
|
|
|
timHighOrderTraceIdentifierMismatchFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TIM High Order - Trace Identifier Mismatch Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4030 }
|
|
|
|
aisAdministrationUnitAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AIS - Administration Unit - Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4040 }
|
|
|
|
lopAdministrationUnitLossOfPointer
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LOP - Administration Unit - Loss of Pointer"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4050 }
|
|
|
|
slmfUnequippedHighOrderPathUnequipped
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLMF - Unequipped High Order - Path Unequipped"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4060 }
|
|
|
|
slmfPLMHighOrderPathLabelMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLMF - PLM High Order - Path Label Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4070 }
|
|
|
|
rdiHighOrderRemoteDefectOrAlarmIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RDI - High Order - Remote Defect/Alarm Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4080 }
|
|
|
|
lopTributaryUnitLossOfPointer
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LOP - Tributary Unit - Loss of Pointer"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4090 }
|
|
|
|
aisTributaryUnitAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"AIS - Tributary Unit - Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4100 }
|
|
|
|
slmfUnequippedLowOrderPathUnequipped
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLMF - Unequipped Low Order - Path Unequipped"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4110 }
|
|
|
|
slmfPLMLowOrderPathLabelMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SLMF - PLM Low Order - Path Label Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4120 }
|
|
|
|
timLowOrderTraceIdentifierMismatchFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TIM Low Order - Trace Identifier Mismatch Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4130 }
|
|
|
|
rfiLowOrderRemoteFailureOrAlarmIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RFI - Low Order - Remote Failure/Alarm Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4140 }
|
|
|
|
g811PrimaryReferenceClockTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "G811 - Primary Reference Clock traceable."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4150 }
|
|
|
|
g812TransitNodeClockTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "G812 - Transit Node Clock traceable."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4160 }
|
|
|
|
g812LocalNodeClockTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "G812 - Local Node Clock traceable."
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4170 }
|
|
|
|
g813SynchronousEquipmentTimingSourceTraceable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"G813 - Synchronous Equipment Timing Source traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4180 }
|
|
|
|
e1LoopbackDueToFEACCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E1 loopback due to FEAC command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4190 }
|
|
|
|
e1LoopbackCommandSentToFarEnd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E1 loopback command sent to Far End"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4200 }
|
|
|
|
e3LoopbackDueToFEACCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E3 loopback due to FEAC command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4210 }
|
|
|
|
farEndMultipleE1LOSDetectedOnE3
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end Multiple E1 LOS detected on E3"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4220 }
|
|
|
|
farEndE1EqptFailNonServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end E1 eqpt fail non service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4230 }
|
|
|
|
farEndE1EqptFailServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end E1 eqpt fail service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4240 }
|
|
|
|
farEndSingleE1LOS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end Single E1 LOS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4250 }
|
|
|
|
farEndE3EqptFailServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end E3 eqpt fail service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4260 }
|
|
|
|
e3LoopbackCommandSentToFarEnd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E3 loopback command sent to far end"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4270 }
|
|
|
|
farEndE3EqptFailNonServiceAffecting
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "far end E3 eqpt fail non service affecting"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4280 }
|
|
|
|
lowVoltBatteryA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Volt - Battery A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4290 }
|
|
|
|
highVoltBatteryA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Volt - Battery A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4300 }
|
|
|
|
lowVoltBatteryB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Volt - Battery B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4310 }
|
|
|
|
highVoltBatteryB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Volt - Battery B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4320 }
|
|
|
|
msspRingOutOfSync
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "MS-SP ring out of sync"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4330 }
|
|
|
|
msspMultiNodeTableUpdateCompleted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MSSP Multi-Node Table Update Completed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4340 }
|
|
|
|
automaticSNCPSwitchCausedByAIS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic SNCP switch caused by AIS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4350 }
|
|
|
|
automaticSNCPSwitchCausedByLOP
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic SNCP switch caused by Lop"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4360 }
|
|
|
|
automaticSNCPSwitchCausedByUNEQ
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic SNCP Switch caused by UNEQ"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4370 }
|
|
|
|
automaticSNCPSwitchCausedByPDI
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "automatic SNCP switch caused by PDI"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4380 }
|
|
|
|
automaticSNCPSwitchCausedBySFBER
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic SNCP Switch caused by SFBER"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4390 }
|
|
|
|
automaticSNCPSwitchCausedBySDBER
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic SNCP Switch caused by SDBER"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4400 }
|
|
|
|
stmConcatenationError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"STM Concatenation error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4410 }
|
|
|
|
e3IdleCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"E3 Idle Condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4420 }
|
|
|
|
channelMSSPInconsistentAPSCode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel MSSP inconsistent APS code"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4430 }
|
|
|
|
|
|
channelMSSPImproperAPSCodeAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel MSSP Improper APS code APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4440 }
|
|
|
|
channelMSSPNodeIdMismatchAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel MSSP Node Id Mismatch APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4450 }
|
|
|
|
channelMSSPDefaultKAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel MSSP Default K APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4460 }
|
|
|
|
channelMSSPConnectionLossAPS
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "channel MSSP Connection loss APS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4470 }
|
|
|
|
minimumClockTraceableSDH
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SDH Minimum clock Traceable"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4480 }
|
|
|
|
lineIsInWaitToRestoreStateSDH
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SDH line is in Wait To Restore state "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4490 }
|
|
|
|
berThresholdExceededForSignalDegradeHighOrder
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Degrade - High Order"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4500 }
|
|
|
|
berThresholdExceededForSignalFailureHighOrder
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Failure - High Order"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4510 }
|
|
|
|
berThresholdExceededForSignalDegradeLowOrder
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Degrade - Low Order"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4520 }
|
|
|
|
berThresholdExceededForSignalFailureLowOrder
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Failure - Low Order"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4530 }
|
|
|
|
failureToSwitchToProtectionHighOrderPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failure To Switch To Protection - High Order Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4540 }
|
|
|
|
failureToSwitchToProtectionLowOrderPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failure To Switch To Protection - Low Order Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4550 }
|
|
|
|
lofAdministrationUnitLossOfMultiFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LOF - Administration Unit - Loss of Multi Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4560 }
|
|
|
|
sdhSpanIsInWaitToRestoreState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SDH span is in Wait To Restore state"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4570 }
|
|
|
|
-- End: SDH Traps
|
|
|
|
a8b10bOutOfSync
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "8B10B Out of Sync"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4755 }
|
|
|
|
odukPMAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ODUk: PM Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4760 }
|
|
|
|
otukAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUk: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4765 }
|
|
|
|
otukSMBackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUk: Backward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4770 }
|
|
|
|
odukBackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: Backward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4775 }
|
|
|
|
fecUncorrectedWord
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "FEC Uncorrected Word"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4780 }
|
|
|
|
gccTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GCC Termination Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4785 }
|
|
|
|
otukIncomingAlignmentError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUk: Incoming Alignment Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4790 }
|
|
|
|
odukLockedDefectPM
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ODUk: Locked Defect - PM"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4795 }
|
|
|
|
lossOfMultiFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Multi-Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4800 }
|
|
|
|
odukOpenConnectionIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: Open Connection Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4805 }
|
|
|
|
payloadTypeIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Type Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4810 }
|
|
|
|
odukTrailTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: Trail Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4815 }
|
|
|
|
otukTrailTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUk: Trail Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4820 }
|
|
|
|
equipmentHighLaserBias
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Laser Bias"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4825 }
|
|
|
|
equipmentHighLaserTemp
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Laser Temp"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4830 }
|
|
|
|
equipmentHighLaserPeltier
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Laser Peltier"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4835 }
|
|
|
|
facilityHighRxPower
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Facility High Rx power"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4840 }
|
|
|
|
equipmentHighTxPower
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Tx power"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4845 }
|
|
|
|
equipmentHighTransceiverVoltage
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Transceiver voltage"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4850 }
|
|
|
|
equipmentLowLaserBias
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Laser Bias"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4855 }
|
|
|
|
equipmentLowLaserTemp
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Laser Temp"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4860 }
|
|
|
|
equipmentLowLaserPeltier
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Laser Peltier "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4865 }
|
|
|
|
facilityLowRxPower
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Facility Low Rx power"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4870 }
|
|
|
|
equipmentLowTxPower
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Tx power"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4875 }
|
|
|
|
equipmentLowTransceiverVoltage
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Transceiver voltage"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4880 }
|
|
|
|
equipmentRxLocked
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Rx Locked"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4885 }
|
|
|
|
equipmentSquelched
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Squelched"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4890 }
|
|
|
|
equipmentTxLocked
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Tx Locked"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4895 }
|
|
|
|
otukSignalFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUK Signal Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4900 }
|
|
|
|
odukSignalFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUK Signal Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4905 }
|
|
|
|
otukSignalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUK Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4910 }
|
|
|
|
odukSignalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUK Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4915 }
|
|
|
|
pluggablePortMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pluggable Port missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4920 }
|
|
|
|
pluggablePortRateMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pluggable Port rate mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4925 }
|
|
|
|
pluggablePortSecurityCodeMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pluggable Port security code mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4930 }
|
|
|
|
tciNotSelected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Tci not selected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4935 }
|
|
|
|
tci1ClockFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Tci 1 Clock Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4940 }
|
|
|
|
odukPMBackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: PM Backward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4945 }
|
|
|
|
odukTCM1BackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: TCM1 Backward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4950 }
|
|
|
|
odukTCM2BackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk: TCM2 Backward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4955 }
|
|
|
|
equipmentHighRxTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment High Rx temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4960 }
|
|
|
|
equipmentLowRxTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Low Rx temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4965 }
|
|
|
|
tci2ClockFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Tci 2 Clock Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4970 }
|
|
|
|
equipmentWavelengthMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Wavelength Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4975 }
|
|
|
|
dspCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DSP Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4980 }
|
|
|
|
dspFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DSP Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 4985 }
|
|
|
|
|
|
laserApproachingEndOfLife
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Laser Approaching End of Life"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5000 }
|
|
|
|
crossconnectLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Cross-connect Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5010 }
|
|
|
|
adminLogoutOfUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Admin Logout of User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5020 }
|
|
|
|
userLockedOut
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "User Locked Out"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5030 }
|
|
|
|
adminLockoutOfUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Admin Lockout of User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5040 }
|
|
|
|
adminLockoutClear
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Admin Lockout Clear"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5050 }
|
|
|
|
invalidLoginUsername
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Invalid Login: Username"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5060 }
|
|
|
|
securityInvalidLoginPassword
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security: Invalid Login - Password - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5070 }
|
|
|
|
securityInvalidLoginLockedOut
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security: Invalid Login - Locked Out - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5080 }
|
|
|
|
securityInvalidLoginAlreadyLoggedOn
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security: Invalid Login - Already Logged On - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5090 }
|
|
|
|
loginOfUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Login of User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5100 }
|
|
|
|
automaticLogoutOfIdleUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Logout of IdleUser"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5110 }
|
|
|
|
logoutOfUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Logout of User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5120 }
|
|
|
|
enhancedRemoteFailureIndicationPathServer
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Enhanced Remote Failure Indication - Path - Server"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5200 }
|
|
|
|
|
|
enhancedRemoteFailureIndicationPathConnectivity
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Enhanced Remote Failure Indication - Path - Connectivity"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5210 }
|
|
|
|
enhancedRemoteFailureIndicationPathPayload
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Enhanced Remote Failure Indication - Path - Payload"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5220 }
|
|
|
|
firewallHasBeenDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Firewall Has Been Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5230 }
|
|
|
|
securityIntrusionDetPwd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security Intrusion Attempt Detected - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5240 }
|
|
|
|
securityIntrusionDetUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Security Intrusion Attempt Detected - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5250 }
|
|
connectionEquipmentMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Connection Equipment Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5260 }
|
|
|
|
disableInactiveUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Disable Inactive User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5270 }
|
|
|
|
disableInactiveClear
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Disable Inactive Clear"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5280 }
|
|
|
|
|
|
batteryFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Battery Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5290 }
|
|
|
|
extremeHighVolt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme High Volt"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5300 }
|
|
|
|
extremeLowVolt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Extreme Low Volt"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5310 }
|
|
|
|
highVolt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Volt"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5320 }
|
|
|
|
lowVolt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Volt"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5330 }
|
|
|
|
suspendUser
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Suspend User"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5340 }
|
|
|
|
suspendUserClear
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Suspend User Clear"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5350 }
|
|
|
|
|
|
lineDccTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Line DCC Termination Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5360 }
|
|
|
|
multiplexSectionDccTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multiplex Section DCC Termination Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5370 }
|
|
|
|
gigaBitEthernetOutOfSync
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"GigaBit Ethernet Out of Sync"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5380 }
|
|
|
|
sequenceMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Sequence Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5390 }
|
|
|
|
lossOfAlignment
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Alignment"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5400 }
|
|
|
|
outOfUseByAdministrativeCommand
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Out of Use - Administrative Command"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5410 }
|
|
|
|
outOfUseTransportFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Out of Use - Transport Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5420 }
|
|
|
|
vcatGroupDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VCAT Group Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5430 }
|
|
|
|
vcatGroupDegraded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VCAT Group Degraded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5440 }
|
|
|
|
vcatGroupIncomplete
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VCAT Group Incomplete"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5450 }
|
|
|
|
alarmIndicationSignalInTX
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Alarm Indication Signal in TX"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5460 }
|
|
|
|
remoteAlarmIndicationInTX
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Remote Alarm Indication in TX"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5470 }
|
|
|
|
kByteAPSChannelFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Kbyte Channel Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5480 }
|
|
|
|
apsInvalidMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "APS Invalid Mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5490 }
|
|
|
|
ipAddressAlreadyInUseWithinTheSameDccArea
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address A1ready In Use Within The Same DCC Area"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5500 }
|
|
|
|
nodeNameInUseWithinTheSameDccArea
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Node name already in use within the same DCC Area"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5510 }
|
|
|
|
rearPanelEthernetLinkRemoved
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Rear Panel Ethernet Link Removed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5520 }
|
|
|
|
manualSwitchToProtectResultedInNoTrafficSwitch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch To Protect Resulted in No Traffic Switch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5530 }
|
|
|
|
manualSwitchBackToWorkingResultedInNoTrafficSwitch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Manual Switch Back To Working Resulted in No Traffic Switch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5540 }
|
|
|
|
forcedSwitchToProtectResultedInNoTrafficSwitch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Forced Switch To Protection Resulted in No Traffic Switch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5550 }
|
|
|
|
forcedSwitchBackToWorkingResultedInNoTrafficSwitch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forced Switch Back To Working Resulted in No Traffic Switch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5560 }
|
|
|
|
duplicateSerialNumberDetectedOnAPluggableEntity
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Duplicate Serial number detected on a pluggable entity"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5570 }
|
|
|
|
lossOfSignalForOpticalChannel
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Incoming Payload Signal Absent"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5600 }
|
|
|
|
encapsulationMismatchPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Encapsulation Mismatch Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5610 }
|
|
|
|
encapsulationMismatchVT
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Encapsulation Mismatch - VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5620 }
|
|
|
|
encapsulationMismatchHighOrderPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Encapsulation Mismatch High Order - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5630 }
|
|
|
|
encapsulationMismatchLowOrderPath
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Encapsulation Mismatch Low Order - Path"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5640 }
|
|
|
|
gfpUserPayloadMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP User Payload Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5650 }
|
|
|
|
gfpFibreChannelDistanceExtensionMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Fibre Channel Distance Extension Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5660 }
|
|
|
|
gfpFibreChannelDistanceExtensionBufferStarvation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Fibre Channel Distance Extension Buffer Starvation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5670 }
|
|
|
|
gfpFibreChannelDistanceExtensionCreditStarvation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Fibre Channel Distance Extension Credit Starvation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5680 }
|
|
|
|
automaticWdmAnsFinished
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Automatic WDM ANS Finished"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5690 }
|
|
|
|
gfpClientSignalFailDetected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Client Signal Fail Detected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5700 }
|
|
|
|
gfpLossOfFrameDelineation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Loss of Frame Delineation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5710 }
|
|
|
|
gfpExtensionHeaderMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Extension Header Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5730 }
|
|
|
|
incomingOverheadSignalAbsent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Incoming Overhead Signal Absent"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5740 }
|
|
|
|
opticalSafetyRemoteInterlockOn
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Safety Remote Interlock On"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5750 }
|
|
|
|
automaticPowerControlCorrectionSkipped
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Power Control Correction Skipped"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5770 }
|
|
|
|
apcCannotSetValueDueToRangeLimits
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "APC cannot set value due to range limits"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5780 }
|
|
|
|
lcasVcgMemberTxSideInAddState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCAS VCG Member Tx Side In ADD State"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5790 }
|
|
|
|
farEndManualSwitchBackToWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Manual Switch Back to Working - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5800 }
|
|
|
|
farEndForcedSwitchBackToWorkingSpan
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Far End Forced Switch Back to Working - Span"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5810 }
|
|
|
|
universalTransponderModuleHardwareFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Universal Transponder Module Hardware Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5820 }
|
|
|
|
universalTransponderModuleCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Universal Transponder Module Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5830 }
|
|
|
|
pluginModuleRangeSettingsMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Plug-in Module Range Settings Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5840 }
|
|
|
|
lcasVcgMemberTxSideInDnuState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCAS VCG Member Tx Side In DNU State"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5850 }
|
|
|
|
lcasControlWordCrcCheckFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCAS Control Word CRC Check Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5860 }
|
|
|
|
lcasVcgMemberRxSideInFailState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LCAS VCG Member Rx Side In FAIL State"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5870 }
|
|
|
|
signalLossOnDataInterface
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Signal Loss on Data Interface"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5880 }
|
|
|
|
synchronizationLossOnDataInterface
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Synchronization Loss on Data Interface"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5890 }
|
|
|
|
portFAIL
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "PORT FAIL"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5900 }
|
|
|
|
unreachablePortTargetPower
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unreachable port target power"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5910 }
|
|
|
|
portAddPowerDegradeLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Port Add Power Degrade Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5920 }
|
|
|
|
portAddPowerDegradeHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Port Add Power Degrade High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5930 }
|
|
|
|
portAddPowerFailLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Port Add Power Fail Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5940 }
|
|
|
|
portAddPowerFailHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Port Add Power Fail High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 5950 }
|
|
|
|
automaticPowerControlTerminatedOnManualRequest
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Power Control Terminated on Manual request"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6000 }
|
|
|
|
oduk1AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk-1: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6010 }
|
|
|
|
oduk2AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk-2: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6020 }
|
|
|
|
oduk3AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk-3: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6030 }
|
|
|
|
oduk4AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk-4: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6040 }
|
|
|
|
temperatureReadingMismatchBetweenSCCards
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Temperature Reading Mismatch Between SC Cards"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6050 }
|
|
|
|
voltageReadingMismatchBetweenSCCards
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Voltage Reading Mismatch Between SC Cards"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6060 }
|
|
|
|
alarmsSuppressedonOutOfGroupVcatMember
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarms Suppressed on Out-Of-Group VCAT Member"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6070 }
|
|
|
|
blsrSoftwareVersionMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BLSR Software Version Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6080 }
|
|
|
|
optimized1Plus1ApsPrimaryFacility
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optimized 1+1 APS Primary Facility"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6090 }
|
|
|
|
optimized1Plus1ApsPrimarySectionMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optimized 1+1 APS Primary Section Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6100 }
|
|
|
|
optimized1Plus1ApsInvalidPrimarySection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optimized 1+1 APS Invalid Primary Section"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6110 }
|
|
|
|
compositeClockHighLineVoltage
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Composite Clock High Line Voltage"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6120 }
|
|
|
|
berThresholdExceededForSignalDegradeVt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Degrade - VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6130 }
|
|
|
|
berThresholdExceededForSignalFailureVt
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"BER Threshold Exceeded For Signal Failure - VT"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6140 }
|
|
|
|
spanLengthOutOfRange
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Span Length Out of Range"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6150 }
|
|
|
|
idleSignalCondition
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Idle Signal Condition"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6170 }
|
|
|
|
idleSignalConditionInTx
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Idle Signal Condition in TX"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6180 }
|
|
|
|
vtPathTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VT Path Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6190 }
|
|
|
|
lossOfFrameInTX
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Frame in TX"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6200 }
|
|
|
|
provisioningMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Provisioning Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6210 }
|
|
|
|
sectionTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Section Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6220 }
|
|
|
|
regeneratorSectionTraceIdentifierMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Regenerator Section Trace Identifier Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6230 }
|
|
|
|
switchingMatrixModuleFailureWorking
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switching Matrix Module Failure - Working"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6240 }
|
|
|
|
switchingMatrixModuleFailureProtect
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Switching Matrix Module Failure - Protect"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6250 }
|
|
|
|
slotCommunicationDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Slot Communication Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6260 }
|
|
|
|
sessionTimeLimitExpired
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Session Time Limit Expired"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6270 }
|
|
|
|
userPasswordChangeRequired
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "User Password Change Required"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6280 }
|
|
|
|
isisAdjacencyFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ISIS Adjacency Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6290 }
|
|
|
|
msspSoftwareVersionMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "MSSP Software Version Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6300 }
|
|
|
|
remoteAuthenticationFailSeeAuditLog
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Remote Authentication Fail - See Audit Log"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6310 }
|
|
|
|
ringIsSquelchingStsTraffic
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring Is Squelching STS Traffic"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6330 }
|
|
|
|
ringIsSquelchingVtTraffic
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring Is Squelching VT Traffic"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6340 }
|
|
|
|
archiveOfAuditLogFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Archival of Audit Log Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6350 }
|
|
|
|
rprWrapped
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Wrapped"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6360 }
|
|
|
|
shelfCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Shelf Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6370 }
|
|
|
|
duplicatedShelfIdentifier
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Duplicated Shelf Identifier"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6380 }
|
|
|
|
softwareMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Software Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6390 }
|
|
|
|
lmpFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LMP Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6400 }
|
|
|
|
opticalTerminationIncomplete
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Termination Incomplete"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6410 }
|
|
|
|
forwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Forward Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6420 }
|
|
|
|
payloadMissingIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Missing Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6430 }
|
|
|
|
spanMeasurementCannotBePerformed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Span loss not checked"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6440 }
|
|
|
|
ringIsSquelchingHighOrderTraffic
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring Is Squelching High Order Traffic"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6450 }
|
|
|
|
ringIsSquelchingLowOrderTraffic
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ring Is Squelching Low Order Traffic"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6460 }
|
|
|
|
badPacketCountExceedsThreshold
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Bad Packet Count Exceeds Threshold"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6470 }
|
|
|
|
linkLayerKeepAliveFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Link Layer Keep-Alive Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6480 }
|
|
|
|
autonegotiationRemoteFailureIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Auto-Negotiation Remote Failure Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6490 }
|
|
|
|
trailSignalFail
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Trail Signal Fail"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6500 }
|
|
|
|
ds1LoopbackCommandSentToFarEnd
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DS1 Loopback Command Sent To Far End"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6510 }
|
|
|
|
multiplexSectionSignalDegraded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Multiplex Section - Signal Degraded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6520 }
|
|
|
|
multiplexSectionExcessiveErrors
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Multiplex Section - Excessive Errors"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6530 }
|
|
|
|
highOrderPathSignalDegraded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Order Path - Signal Degraded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6540 }
|
|
|
|
highOrderPathExcessiveErrors
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Order Path - Excessive Errors"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6550 }
|
|
|
|
lowOrderPathSignalDegraded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Order Path - Signal Degraded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6560 }
|
|
|
|
lowOrderPathExcessiveErrors
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Low Order Path - Excessive Errors"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6570 }
|
|
|
|
regeneratorSectionDccTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Regenerator Section - DCC Termination Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6580 }
|
|
|
|
networkMemoryPoolLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Network Memory Pool Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6590 }
|
|
|
|
ospfRoutingTableOverflow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OSPF Routing Table Overflow"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6600 }
|
|
|
|
autoLaserShutdownDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Auto Laser Shutdown Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6610 }
|
|
|
|
rprProtectionIsActive
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Protection Is Active"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6630 }
|
|
|
|
maxRPRStationNumberExceeded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Max RPR Station Number Exceeded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6640 }
|
|
|
|
rprProtectionConfigurationMismatched
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Protection Configuration Mismatched"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6650 }
|
|
|
|
reservedBandwidthLinkRateExceededOnRinglet0
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet0"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6660 }
|
|
|
|
reservedBandwidthLinkRateExceededOnRinglet1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Reserved Bandwidth Link Rate Exceeded On Ringlet1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6670 }
|
|
|
|
rprInterfaceInPassThroughMode
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Interface In Pass Through Mode"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6680 }
|
|
|
|
rprPeerNodeIsMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Peer Node is Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6690 }
|
|
|
|
rprRiFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RPR RI Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6700 }
|
|
|
|
rprSignalFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Signal Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6710 }
|
|
|
|
rprSignalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6720 }
|
|
|
|
interlinkFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ADM Peer Cards Interlink Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6730 }
|
|
|
|
apcWrongGain
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "APC Wrong Gain Set Point"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6740 }
|
|
|
|
rprSpanMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "RPR Span Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6750 }
|
|
|
|
efmRemoteFaultIndicationCriticalEvent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Remote Fault Inidication- Critical Event"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6760 }
|
|
|
|
efmRemoteFaultIndicationDyingGasp
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Remote Fault Inidication- Dying Gasp"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6770 }
|
|
|
|
efmRemoteFaultIndicationLinkFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Remote Fault Inidication- Link Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6780 }
|
|
|
|
efmLinkMonitoringErroredSymbolPeriodEvent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Link Monitoring- Errored Symbol Period Event"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6790 }
|
|
|
|
efmLinkMonitoringErroredFrameEvent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Link Monitoring- Errored Frame Event"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6800 }
|
|
|
|
efmLinkMonitoringErroredFramePeriodEvent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Link Monitoring- Errored Frame Period Event"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6810 }
|
|
|
|
efmLinkMonitoringErroredFrameSecondsSummary
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Link Monitoring- Errored Frame Seconds Summary"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6820 }
|
|
|
|
efmRemoteLoopbackRequestFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Remote Loopback Request Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6830 }
|
|
|
|
fastAutomaticProtectionSwitching
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fast Automatic Protection Switching"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6840 }
|
|
|
|
fastAutomaticProtectionSwitchingConfigMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fast Automatic Protection Switching Config Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6850 }
|
|
|
|
lcasSinkGroupError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LCAS Sink Group Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6860 }
|
|
|
|
lcasVcgMemberRxSideInDnuState
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LCAS VCG Member Rx Side In DNU State"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6870 }
|
|
|
|
fcDistanceExtFuncNotEstablished
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION " Fibre Channel Distance Extension Function Not Established"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6880 }
|
|
|
|
nonCiscoPPMInserted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Non Cisco PPM Inserted"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6890 }
|
|
|
|
unqualifiedPPMInserted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unqualified PPM Inserted"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6900 }
|
|
|
|
ftaMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "FanTray Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6910 }
|
|
|
|
cardPortsUnableToProvideProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Card/Ports Unable To Provide Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6920 }
|
|
|
|
lmpSignalDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LMP Signal Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6930 }
|
|
|
|
lmpSignalFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LMP Signal Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6940 }
|
|
|
|
lmpUnallocatedDataLink
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "LMP Unallocated Data Link"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6950 }
|
|
|
|
frontPortLinkLoss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "TCC Front Port Link Loss"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6960 }
|
|
|
|
bertEnbl
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BERT Enabled "
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6970 }
|
|
|
|
bertSyncFail
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "BERT Synchronization Status Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6975 }
|
|
|
|
workQueueFull
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Work Queue Full"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 6980 }
|
|
|
|
equipmentPowerFailureAtConnectorA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment power failure at connector A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7000 }
|
|
|
|
equipmentPowerFailureAtConnectorB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment power failure at connector B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7005 }
|
|
|
|
equipmentPowerFailureAtReturnConnectorA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment power failure at return connector A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7010 }
|
|
|
|
equipmentPowerFailureAtReturnConnectorB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment power failure at return connector B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7015 }
|
|
|
|
bridgeAndRollHasOccurred
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Bridge and Roll Has Occurred"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7055 }
|
|
|
|
bridgeAndRollIsPendingAValidSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Bridge and Roll is Pending a Valid Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7060 }
|
|
|
|
clockBusFailureTscA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Bus Failure - Shelf Controller A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7160 }
|
|
|
|
clockBusFailureTscB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Bus Failure - Shelf Controller B"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7165 }
|
|
|
|
ospfHelloFail
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OSPF Hello Fail"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7185 }
|
|
|
|
openIOSlots
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Open IO Slots"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7200 }
|
|
|
|
lossOfClockFromMateShelfController
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Clock from Mate Shelf Controller"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7210 }
|
|
|
|
virtualLanAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Virtual Lan AIS"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7225 }
|
|
|
|
dcuLossFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "DCU Loss Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7230 }
|
|
|
|
ochncMaintenance
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OCHNC Maintenance"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7235 }
|
|
|
|
ramanLaserShutdown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Raman Laser Shutdown"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7240 }
|
|
|
|
losOfRamanSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss Of Raman Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7245 }
|
|
|
|
mcastMacTableFull
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Multicast Mac Address Table Full"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7250 }
|
|
|
|
multicastMacAddressAliasing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Multicast Mac Address Aliasing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7255 }
|
|
|
|
ramanPwrProtOn
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Raman Power Protection On"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7260 }
|
|
|
|
cppPeerNotResponding
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CPP Peer Not Responding"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7265 }
|
|
|
|
voaControlLoopDisableDueToExcessiveCounterPropagationLight
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VOA Control Loop Disable Due To Excessive Counter-Propagation Light"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7275 }
|
|
|
|
wizardIsRunning
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Wizard Is Running"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7280 }
|
|
|
|
ramanGainNotReached
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Raman Span Not Tuned"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7285 }
|
|
|
|
|
|
pprForwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "pprForwardDefectIndication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7295 }
|
|
|
|
pprBackwardDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "pprBackwardDefectIndication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7300 }
|
|
|
|
pprCoordinatedMaintenance
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "pprCoordinatedMaintenance"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7305 }
|
|
|
|
pprTriggerThresholdBERExceeded
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "pprTriggerThresholdBERExceeded"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7310 }
|
|
|
|
localFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Local Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7315 }
|
|
|
|
remoteFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Remote Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7320 }
|
|
|
|
efmRemoteLoopbackConfigured
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Port In Remote Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7325 }
|
|
|
|
efmPeerMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "EFM Link To Peer Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7330 }
|
|
|
|
eqptDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Equipment Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7335 }
|
|
|
|
excessiveBackPropagation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Excessive Back Propagation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7340 }
|
|
|
|
remoteMaintenanceEndPointIsDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CFM Remote Maintenance End Point Is Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7345 }
|
|
|
|
crossConnectedCFMService
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Cross Connected CFM Service"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7350 }
|
|
|
|
cfmLoop
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CFM Loop"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7355 }
|
|
|
|
cfmConfigurationError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CFM Configuration Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7360 }
|
|
|
|
outOfChannelGroupBundle
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Out Of Channel Group Bundle"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7365 }
|
|
|
|
repNeighborAdjacencyFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "REP Neighbor Adjacency Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7370 }
|
|
|
|
repLinkFlapping
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "REP Link Flapping"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7375 }
|
|
|
|
faultInREPSegment
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fault In REP Segment"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7380 }
|
|
|
|
primaryREPEdgePortElected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Primary REP Edge Port Elected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7385 }
|
|
|
|
secondaryREPEdgePortElected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Secondary REP Edge Port Elected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7390 }
|
|
|
|
stcnREPGenerated
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "STCN REP Generated"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7395 }
|
|
|
|
vlbREPActivated
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VLB REP Activated"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7400 }
|
|
|
|
vlbREPTriggerSoakingDelayActive
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "VLB REP Trigger Soaking Delay Active"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7405 }
|
|
|
|
|
|
wanSyncloss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ethernet Syncloss On WAN Port"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7410 }
|
|
|
|
laserShutdownDueToWavelengthDrift
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "laser Shutdown Due To Wavelength Drift"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7415 }
|
|
|
|
manualLaserRestart
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "manual Laser Restart"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7420 }
|
|
|
|
laserShutdownDueToNonCiscoPPMInserted
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "laserShutdownDueToNonCiscoPPMInserted"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7425 }
|
|
|
|
ethernetOSCTerminationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ethernet OSC Termination Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7430 }
|
|
|
|
softwareSignatureVerificationFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "software Signature Verification Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7445 }
|
|
|
|
protectVolumeSoftwareSignatureVerificationFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Volume Software Signature Verification"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7450 }
|
|
|
|
activeVolumeSoftwareSignatureVerificationFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Active Software Signature Verification Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7455 }
|
|
|
|
peerPortClientSignalFailDetected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Peer Port Client Signal Fail Detected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7460 }
|
|
|
|
channelShutdownDueToWavelengthDrift
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Channel Shutdown Due to Wavelength Drift"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7465 }
|
|
|
|
usbWriteFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "USB Write Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7475 }
|
|
|
|
usbSyncInProgress
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "USB Sync in Progress"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7480 }
|
|
|
|
autoSensingUnableToDetectValidPayload
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Auto-Sensing Unable To Detect Valid Payload"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7485 }
|
|
|
|
payloadAutoSensingInProgress
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Auto-Sensing In Progress"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7490 }
|
|
|
|
gfpClientSignalFailDetectedDueToSigloss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Client Signal Fail Detected Due To Sigloss"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7495 }
|
|
|
|
gfpClientSignalFailDetectedDueToSyncloss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "GFP Client Signal Fail Detected Due To Syncloss"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7500 }
|
|
|
|
pmdDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "PMD Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7510 }
|
|
|
|
standbyTccNEClockIsInternalClock
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Standby Tcc NE Clock Is Internal Clock"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7515 }
|
|
|
|
chromaticDispersionValue
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "chromatic Dispersion Value"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7520 }
|
|
|
|
packetTransportServiceFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Packet Transport Service Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7525 }
|
|
|
|
satellitePanelDiscoveryFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Discovery Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7530 }
|
|
|
|
satellitePanelActiveLinkFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Active Link Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7535 }
|
|
|
|
satellitePanelCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7540 }
|
|
|
|
satellitePanelImproperConfiguration
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Improper Configuration"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7545 }
|
|
|
|
satellitePanelFanMismatchOfEquipmentAndAttributes
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Fan Mismatch Of Equipment And Attributes"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7550 }
|
|
|
|
satellitePanelFanFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Fan Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7555 }
|
|
|
|
satellitePanelPartialFanFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Partial Fan Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7560 }
|
|
|
|
satellitePanelFANManufacturingDataMemoryEEPROMFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel FAN Manufacturing Data Memory (EEPROM) Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7565 }
|
|
|
|
satellitePanelFANUnitIsMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel FAN Unit Is Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7570 }
|
|
|
|
satellitePanelIndustrialHighTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Industrial High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7575 }
|
|
|
|
satellitePanelHighTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7580 }
|
|
|
|
satellitePanelBatteryFailureA
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Satellite Panel Battery Failure A"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7585 }
|
|
|
|
plannedSwitchOver
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Planned Switch Over"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7590 }
|
|
|
|
protectionCardConfigurationMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "protection CardConfiguration Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7595 }
|
|
|
|
routerProcessorSwitchOver
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Router Processor Switch Over"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7600 }
|
|
|
|
runningLowOnResources
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Running Low On Resources"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7605 }
|
|
|
|
noMoreResourcesAreAvailable
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "No More Resources Are Available"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7610 }
|
|
|
|
esmcFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ESMC Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7615 }
|
|
|
|
licenseWillExpireWithin24Hours
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "License Will Expire Within 24 Hours"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7620 }
|
|
|
|
licenseWillExpireAnytimeAfter1DayButBefore14Days
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "license Will Expire Anytime After 1Day But Before 14Days"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7625 }
|
|
|
|
licenseIsExpired
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "license Is Expired"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7630 }
|
|
|
|
licenseCountViolation
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "license Count Violation"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7635 }
|
|
|
|
temporaryLicenseIsInUse
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Temporary License Is In Use"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7640 }
|
|
|
|
evaluationLicenseIsInUse
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Evaluation License Is In Use"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7645 }
|
|
|
|
licenseIsMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "License Is Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7650 }
|
|
|
|
pseudowireDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pseudowire Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7655 }
|
|
|
|
workingPseudowireControlPlaneDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Pseudowire Control Plane Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7660 }
|
|
|
|
protectPseudowireControlPlaneDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Control Plane Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7665 }
|
|
|
|
workingPseudowireConnectivityCheckDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Pseudowire Connectivity Check Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7670 }
|
|
|
|
protectPseudowireConnectivityCheckDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Connectivity Check Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7675 }
|
|
|
|
pseudowireTrafficSwitchedToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Pseudowire Traffic Switched To Pretection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7680 }
|
|
|
|
workingPseudowireLocalAcTxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Pseudowire Local AcTx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7685 }
|
|
|
|
protectPseudowireLocalAcTxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Local AcTx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7690 }
|
|
|
|
workingPseudowireLocalAcRxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Pseudowire Local AcRx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7695 }
|
|
|
|
protectPseudowireLocalAcRxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Local AcRx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7700 }
|
|
|
|
workingPseudowireRemoteAcTxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Pseudowire Remote AcTx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7705 }
|
|
|
|
protectPseudowireRemoteAcTxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Remote AcTx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7710 }
|
|
|
|
workingPseudowireRemoteAcRxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "working Pseudowire Remote AcRx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7715 }
|
|
|
|
protectPseudowireRemoteAcRxPortFault
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Pseudowire Remote AcRx Port Fault"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7720 }
|
|
|
|
slaThresholdCrossAlert
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SLA Threshold Cross Alert"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7725 }
|
|
|
|
protectLocalPseudowireNotForwarding
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Local Pseudowire Not Forwarding"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7730 }
|
|
|
|
workingPseudowireNotForwarding
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Remote Pseudowire Not Forwarding"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7735 }
|
|
|
|
protectPseudowireNotForwarding
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Remote Pseudowire Not Forwarding"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7740 }
|
|
|
|
tpTunnelDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Tp Tunnel Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7745 }
|
|
|
|
workingLabelSwitchedPathDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Label Switched Path Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7750 }
|
|
|
|
protectLabelSwitchedPathDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Label Switched Path Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7755 }
|
|
|
|
workingLabelSwitchedPathAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Label Switched Path Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7760 }
|
|
|
|
protectLabelSwitchedPathAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Label Switched Path Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7765 }
|
|
|
|
workingLabelSwitchedPathRemoteDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Label Switched Path Remote Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7770 }
|
|
|
|
protectLabelSwitchedPathRemoteDefectIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Label Switched Path Remote Defect Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7775 }
|
|
|
|
bidirectionalForwardDetectionDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Bidirectional Forward Detection Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7780 }
|
|
|
|
tpTrafficSwitchedFromWorkingToProtection
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Tp Traffic Switched From Working To Protection"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7785 }
|
|
|
|
workingTpLockout
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "working Tp Lockout"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7790 }
|
|
|
|
protectTpLockout
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "protect Tp Lockout"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7795 }
|
|
|
|
|
|
ethernetFlowPointFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ethernet Flow Point Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7800 }
|
|
|
|
teTunnelDown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "TE Tunnel Down"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7805 }
|
|
|
|
macSystemLimitReached
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "MAC System Limit Reached"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7810 }
|
|
|
|
macBridgeDomainLimitReached
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "MAC Bridge Domain Limit Reached"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7815 }
|
|
|
|
autoSensingDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Auto Sense Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7820 }
|
|
|
|
smBackwardIncomingAlignmentError
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "SM Backward Incoming Alignment Error"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7825 }
|
|
|
|
resourceAllocationFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Resource Allocation Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7830 }
|
|
|
|
lossOfDFBSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "loss Of DFB Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7835 }
|
|
|
|
|
|
workingLabelSwitchedPathLinkDownIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Label Switched Path Link Down Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7840 }
|
|
|
|
protectLabelSwitchedPathLinkDownIndication
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Label Switched Path Link Down Indication"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7845 }
|
|
|
|
workingLabelSwitchedPathLockReport
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Working Label Switched Path Lock Report"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7850 }
|
|
|
|
protectLabelSwitchedPathLockReport
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Protect Label Switched Path Lock Report"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7855 }
|
|
|
|
satellitePanelBatteryFailureB
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "satellite Panel Battery FailureB"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7860 }
|
|
|
|
highBitErrorRate
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "High Bit Error Rate"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7865 }
|
|
|
|
backPanelFacilityLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Back Panel Facility Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7870 }
|
|
|
|
backPanelTerminalLoopback
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Back Panel Terminal Loopback"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7875 }
|
|
|
|
trunkPayloadTypeMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Payload Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7880 }
|
|
|
|
invalidMuxponderConfiguration
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Invalid Muxponder Configuration"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7885 }
|
|
|
|
coolingProfileMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Cooling Profile Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7890 }
|
|
|
|
trunkOduAlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Trunk ODU: Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7895 }
|
|
|
|
companionCardMissing
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Companion Card Missing"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7900 }
|
|
|
|
controlPlaneUnverifiedClearedAlarmsPresent
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Control Plane Unverified Cleared Alarms Present"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7905 }
|
|
|
|
powerConsumptionLimitHasCrossed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Power Consumption Limit Has Crossed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7910 }
|
|
|
|
masterKeyExchangeFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Master Key Exchange Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7915 }
|
|
|
|
unitHighTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Unit High Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7930 }
|
|
|
|
overTemperatureUnitProtected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Over Temperature Unit Protected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7935 }
|
|
|
|
seqMismatchCount
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Sequence Mismatch Count"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7945 }
|
|
|
|
keyProgramOnAlteraFpgaFailed
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Key Program On Altera FPGA Failed"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7960 }
|
|
|
|
duplicateNodeControllerDetected
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Duplicate Node Controller Detected"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7970 }
|
|
|
|
restorationInProg
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Restoration in Progress"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7975 }
|
|
|
|
ramanPumpsCalibrationProcedureIsRunning
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Raman Calibration Running"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7980 }
|
|
|
|
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Raman Calibration Pending"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 7985 }
|
|
|
|
odukTCM1AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ODUk: TCM1 Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13100 }
|
|
|
|
odukTCM2AlarmIndicationSignal
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ODUk: TCM2 Alarm Indication Signal"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13105 }
|
|
|
|
odukLockedDefectTCM1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Locked Defect - TCM1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13110 }
|
|
|
|
odukLockedDefectTCM2
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Locked Defect - TCM2"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13115 }
|
|
|
|
otukLossOfFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "OTUk: Loss Of Frame"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13120 }
|
|
|
|
odukOpenConnectionIndicationTCM1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Open Connection Indication TCM1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13125 }
|
|
|
|
odukOpenConnectionIndicationTCM2
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Open Connection Indication TCM2"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13130 }
|
|
|
|
odukTrailTraceIdentifierMismatchTCM1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13135 }
|
|
|
|
odukTrailTraceIdentifierMismatchTCM2
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Trail Trace Identifier Mismatch TCM2"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13140 }
|
|
|
|
odukSignalFailureTCM1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Signal Failure - TCM1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13145 }
|
|
|
|
odukSignalFailureTCM2
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Signal Failure - TCM2"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13150 }
|
|
|
|
odukSignalDegradeTCM1
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Signal Degrade - TCM1"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13155 }
|
|
|
|
odukSignalDegradeTCM2
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "ODUk Signal Degrade - TCM2"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13160 }
|
|
|
|
lossOfChannel
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss of Channel"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13165 }
|
|
|
|
fecMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "FEC Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13170 }
|
|
|
|
timSectionMonitorTraceIdentifierMismatchFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "TIM Section Monitor - Trace Identifier Mismatch Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13175 }
|
|
|
|
automaticLaserShutdown
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Laser Shutdown"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13180 }
|
|
|
|
shutterInsertionLossVariationDegradeLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Shutter Insertion Loss Variation Degrade Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13200 }
|
|
|
|
opticalChannelDeactivationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Channel de-activation failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13205 }
|
|
|
|
shutterInsertionLossVariationDegradeHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Shutter Insertion Loss Variation Degrade High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13210 }
|
|
|
|
networkTopologyIncomplete
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Network Topology Incomplete"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13215 }
|
|
|
|
pluginModuleCommunicationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Plug-in Module Communication Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13220 }
|
|
|
|
opticalNetworkTypeMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Network Type Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13225 }
|
|
|
|
opticalPowerDegradeLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optical Power Degrade Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13230 }
|
|
|
|
automaticPowerControlFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Power Control Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13235 }
|
|
|
|
opticalPowerDegradeHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Power Degrade High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13240 }
|
|
|
|
automaticPowerControlDisabled
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Automatic Power Control Disabled"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13245 }
|
|
|
|
opticalPowerFailureLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Power Failure Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13250 }
|
|
|
|
ringIdMismatch
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Ring Id Mismatch"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13255 }
|
|
|
|
opticalPowerFailureHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Power Failure High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13260 }
|
|
|
|
lossOfContinuity
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Loss Of Continuity"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13270 }
|
|
|
|
variableOpticalAttenuatorDegradeLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Variable Optical Attenuator Degrade Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13280 }
|
|
|
|
variableOpticalAttenuatorDegradeHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Variable Optical Attenuator Degrade High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13290 }
|
|
|
|
variableOpticalAttenuatorFailureLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Variable Optical Attenuator Failure Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13300 }
|
|
|
|
variableOpticalAttenuatorFailureHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Variable Optical Attenuator Failure High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13310 }
|
|
|
|
laserBiasDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Laser Bias Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13320 }
|
|
|
|
laserBiasFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "aser Bias Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13330 }
|
|
|
|
laserTemperatureDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Laser Temperature Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13340 }
|
|
|
|
opticalAmplifierGainDegradeLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Amplifier Gain Degrade Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13350 }
|
|
|
|
opticalAmplifierGainDegradeHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Amplifier Gain Degrade High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13360 }
|
|
|
|
opticalAmplifierGainFailureLow
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Amplifier Gain Failure Low"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13370 }
|
|
|
|
opticalAmplifierGainFailureHigh
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Amplifier Gain Failure High"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13380 }
|
|
|
|
opticalChannelConnectionFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Channel connection failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13390 }
|
|
|
|
opticalChannelIncomplete
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Channel Incomplete"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13395 }
|
|
|
|
opticalChannelActivationFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Channel activation failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13400 }
|
|
|
|
laserAutoPowerReduction
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Laser Auto Power Reduction"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13410 }
|
|
|
|
caseTemperatureDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Case Temperature Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13420 }
|
|
|
|
fiberTemperatureDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Fiber Temperature Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13430 }
|
|
|
|
shutterOpen
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Shutter Open"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13440 }
|
|
|
|
awgTemperatureDegrade
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "AWG Temperature Degrade"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13450 }
|
|
|
|
awgTemperatureFailure
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "AWG Temperature Failure"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13460 }
|
|
|
|
awgOverTemperature
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "AWG Over-Temperature"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13470 }
|
|
|
|
opticalAmplifierInitialization
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Optical Amplifier Initialization"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13480 }
|
|
|
|
awgWarmUp
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "AWG Warm Up"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13490 }
|
|
|
|
incSigloss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Incoming Signal Loss on Fibre Channel Interface"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13510 }
|
|
|
|
incSyncloss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Incoming Synchronization Loss on Fibre Channel Interface"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13515 }
|
|
|
|
incGfpOutOfFrame
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Out Of Frame Detected by GFP Receiver"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13520 }
|
|
|
|
incGfpSigLoss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Client Signal Loss Frames Detected by GFP Receiver"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13525 }
|
|
|
|
incGfpSyncLoss
|
|
NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
cerent454NodeTime,
|
|
cerent454AlarmState,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Client Sychronization Loss Frames Detected by GFP Receiver"
|
|
--#SUMMARY "%d Object:%d Index:%d Slot:%d Port:%d AID:%s"
|
|
--#ARGUMENTS {$2, $3, $4, $5, $6, $8}
|
|
--#GENERIC 6
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { cerent454V2Events 13530 }
|
|
|
|
node454Group OBJECT-GROUP
|
|
OBJECTS {
|
|
cerent454SoftwareVersion }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for node related objects"
|
|
::= { cerent454Groups 10 }
|
|
|
|
alarm454Group OBJECT-GROUP
|
|
OBJECTS {
|
|
cerent454AlarmCount,
|
|
cerent454AlarmObjectIndex,
|
|
cerent454AlarmObjectType,
|
|
cerent454AlarmSlotNumber,
|
|
cerent454AlarmPortNumber,
|
|
cerent454AlarmLineNumber,
|
|
cerent454AlarmType,
|
|
cerent454AlarmState,
|
|
cerent454AlarmSeverity,
|
|
cerent454AlarmStatus,
|
|
cerent454AlarmServiceAffecting,
|
|
cerent454AlarmTimeStamp,
|
|
cerent454AlarmObjectName,
|
|
cerent454AlarmAdditionalInfo
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for node related objects"
|
|
::= { cerent454Groups 20 }
|
|
|
|
event454Group NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
alarmUnknown,
|
|
alarmCutoffIsInManualMode,
|
|
failureDetectedExternalToTheNE,
|
|
externalError,
|
|
excessiveSwitching,
|
|
sdccTerminationFailure,
|
|
incomingFailureCondition,
|
|
alarmIndicationSignal,
|
|
alarmIndicationSignalLine,
|
|
alarmIndicationSignalPath,
|
|
alarmIndicationSignalVT,
|
|
apsChannelFailure,
|
|
channelByteFailureAPS,
|
|
channelProtectionSwitchingChannelMatchFailureAPS,
|
|
channelAutomaticProtectionSwitchModeMismatchAPS,
|
|
farEndProtectionLineFailure,
|
|
inconsistentAPSCode,
|
|
improperAPSCode,
|
|
nodeIdMismatch,
|
|
channelDefaultKAPS,
|
|
connectionLoss,
|
|
bipolarViolation,
|
|
carrierLossOnTheLAN,
|
|
concatenationErrorSTS,
|
|
excessCollisionsOnTheLAN,
|
|
facilityFailure,
|
|
farEndAIS,
|
|
farEndMultipleDS1LOSDetectedOnDS3,
|
|
farEndDS1EqptFailNonServiceAffecting,
|
|
farEndDS1EqptFailServiceAffecting,
|
|
farEndSingleDS1LOS,
|
|
farEndDS3EqptFailNonServiceAffecting,
|
|
farEndDS3EqptFailServiceAffecting,
|
|
farEndCommonEquipmentFailureNonServiceAffecting,
|
|
farEndIDLE,
|
|
farEndLOS,
|
|
farEndLOF,
|
|
farEndBlockError,
|
|
ds3IdleCondition,
|
|
lossOfFrame,
|
|
lossOfPointer,
|
|
lossOfPointerPath,
|
|
lossOfPointerVT,
|
|
lossOfSignal,
|
|
outOfFrame,
|
|
pathSelectorFailure,
|
|
remoteAlarmIndication,
|
|
remoteFailureIndication,
|
|
remoteFailureIndicationLine,
|
|
remoteFailureIndicationPath,
|
|
remoteFailureIndicationVT,
|
|
signalDegrade,
|
|
severelyErroredFrame,
|
|
signalFailure,
|
|
signalLabelMismatchFailure,
|
|
payloadDefectIndication,
|
|
payloadDefectIndicationPath,
|
|
payloadLabelMismatchPath,
|
|
signalLabelMismatchFailurePayloadLabelMismatchVT,
|
|
unequippedPath,
|
|
signalLabelMismatchFailureUnequippedVT,
|
|
lossOfSynchronization,
|
|
outOfSynchronization,
|
|
primarySynchronizationReferenceFailure,
|
|
secondarySynchronizationReferenceFailure,
|
|
thirdSynchronizationReferenceFailure,
|
|
fourthSynchronizationReferenceFailure,
|
|
fifthSynchronizationReferenceFailure,
|
|
sixthSynchronizationReferenceFailure,
|
|
failedToReceiveSynchronizationStatusMessage,
|
|
synchronizationStatusMessagesAreDisabledOnThisInterface,
|
|
stratum1PrimaryReferenceSourceTraceable,
|
|
synchronizedTraceabilityUnknown,
|
|
stratum2Traceable,
|
|
transitNodeClockTraceable,
|
|
stratum3ETraceable,
|
|
stratum3Traceable,
|
|
sonetMinimumClockTraceable,
|
|
stratum4Traceable,
|
|
doNotUseForSynchronization,
|
|
reservedForNetworkSynchronizationUse,
|
|
outgoingFailureCondition,
|
|
remoteDefectIndicationLine,
|
|
remoteDefectIndicationPath,
|
|
freeRunningSynchronizationMode,
|
|
holdoverSynchronizationMode,
|
|
fastStartSynchronizationMode,
|
|
internalFault,
|
|
internalError,
|
|
internalMessageError,
|
|
mismatchOfEquipmentAndAttributes,
|
|
watchdogTimerTimeout,
|
|
softwareFaultOrFailure,
|
|
softwareFaultDataIntegrityFault,
|
|
programFailure,
|
|
controlEquipmentFailure,
|
|
primaryNonVolatileBackupMemoryFailure,
|
|
secondaryNonVolatileBackupMemoryFailure,
|
|
controlBusFailure,
|
|
controlBus1Failure,
|
|
controlBus2Failure,
|
|
tccAToShelfSlot1DROP1CommunicationFailure,
|
|
tccAToShelfSlot2DROP2CommunicationFailure,
|
|
tccAToShelfSlot3DROP3CommunicationFailure,
|
|
tccAToShelfSlot4DROP4CommunicationFailure,
|
|
tccAToShelfSlot5TRUNK1CommunicationFailure,
|
|
tccAToShelfSlot6TRUNK2CommunicationFailure,
|
|
tccAToShelfSlot7TCCACommunicationFailure,
|
|
tccAToShelfSlot8XCONACommunicationFailure,
|
|
tccAToShelfSlot9AICCommunicationFailure,
|
|
tccAToShelfSlot10XCONBCommunicationFailure,
|
|
tccAToShelfSlot11TCCBCommunicationFailure,
|
|
tccAToShelfSlot12TRUNK3CommunicationFailure,
|
|
tccAToShelfSlot13TRUNK4CommunicationFailure,
|
|
tccAToShelfSlot14DROP5CommunicationFailure,
|
|
tccAToShelfSlot15DROP6CommunicationFailure,
|
|
tccAToShelfSlot16DROP7CommunicationFailure,
|
|
tccAToShelfSlot17DROP8CommunicationFailure,
|
|
tccAToDCCAProcessorCommunicationFailure,
|
|
tccBToShelfSlot1DROP1CommunicationFailure,
|
|
tccBToShelfSlot2DROP2CommunicationFailure,
|
|
tccBToShelfSlot3DROP3CommunicationFailure,
|
|
tccBToShelfSlot4DROP4CommunicationFailure,
|
|
tccBToShelfSlot5TRUNK1CommunicationFailure,
|
|
tccBToShelfSlot6TRUNK2CommunicationFailure,
|
|
tccBToShelfSlot7TCCACommunicationFailure,
|
|
tccBToShelfSlot8XCONACommunicationFailure,
|
|
tccBToShelfSlot9AICCommunicationFailure,
|
|
tccBToShelfSlot10XCONBCommunicationFailure,
|
|
tccBToShelfSlot11TCCBCommunicationFailure,
|
|
tccBToShelfSlot12TRUNK3CommunicationFailure,
|
|
tccBToShelfSlot13TRUNK4CommunicationFailure,
|
|
tccBToShelfSlot14DROP5CommunicationFailure,
|
|
tccBToShelfSlot15DROP6CommunicationFailure,
|
|
tccBToShelfSlot16DROP7CommunicationFailure,
|
|
tccBToShelfSlot17DROP8CommunicationFailure,
|
|
tccBToDCCBProcessorCommunicationFailure,
|
|
controlEquipmentControlCommunicationsEquipmentFailure,
|
|
controlProcessorFailure,
|
|
workingMemoryFailure,
|
|
interconnectionEquipmentFailure,
|
|
payloadBusFailureToIOSlot1XCONSlot8,
|
|
payloadBusFailureToIOSlot2XCONSlot8,
|
|
payloadBusFailureToIOSlot3XCONSlot8,
|
|
payloadBusFailureToIOSlot4XCONSlot8,
|
|
payloadBusFailureToIOSlot5XCONSlot8,
|
|
payloadBusFailureToIOSlot6XCONSlot8,
|
|
payloadBusFailureToIOSlot12XCONSlot8,
|
|
payloadBusFailureToIOSlot13XCONSlot8,
|
|
payloadBusFailureToIOSlot14XCONSlot8,
|
|
payloadBusFailureToIOSlot15XCONSlot8,
|
|
payloadBusFailureToIOSlot16XCONSlot8,
|
|
payloadBusFailureToIOSlot17XCONSlot8,
|
|
payloadBusFailureToIOSlot1XCONSlot10,
|
|
payloadBusFailureToIOSlot2XCONSlot10,
|
|
payloadBusFailureToIOSlot3XCONSlot10,
|
|
payloadBusFailureToIOSlot4XCONSlot10,
|
|
payloadBusFailureToIOSlot5XCONSlot10,
|
|
payloadBusFailureToIOSlot6XCONSlot10,
|
|
payloadBusFailureToIOSlot12XCONSlot10,
|
|
payloadBusFailureToIOSlot13XCONSlot10,
|
|
payloadBusFailureToIOSlot14XCONSlot10,
|
|
payloadBusFailureToIOSlot15XCONSlot10,
|
|
payloadBusFailureToIOSlot16XCONSlot10,
|
|
payloadBusFailureToIOSlot17XCONSlot10,
|
|
timeSlotInterchangeEquipmentFailure,
|
|
equipmentFailure,
|
|
highTemperature,
|
|
invalidMACAddress,
|
|
boardFailure,
|
|
diagnosticFailure,
|
|
mediumAccessControlFailure,
|
|
facilityTerminationEquipmentFailure,
|
|
automaticLaserShutoffDueToHighTemperature,
|
|
failureToReleaseFromProtection,
|
|
receiverFailure,
|
|
transmitFailure,
|
|
facilityTerminationEquipmentReceiverMissing,
|
|
facilityTerminationEquipmentTransmitterMissing,
|
|
failureToSwitchToProtection,
|
|
failureToSwitchToProtectionRing,
|
|
failureToSwitchToProtectionSpan,
|
|
failureToSwitchToProtectionPath,
|
|
fanFailure,
|
|
equipmentUnitPlugIn,
|
|
nePowerFailureAtConnector,
|
|
fuseAlarm,
|
|
synchronizationUnitFailure,
|
|
synchronizationSwitchingEquipmentFailure,
|
|
equipmentUnitUnplugged,
|
|
loopback,
|
|
ds1LoopbackDueToFEACCommand,
|
|
loopbackCommandSentToFarEndDS1,
|
|
ds3LoopbackDueToFEACCommand,
|
|
ds3LoopbackCommandSentToFarEnd,
|
|
ds2LoopbackDueToFarEndCommand,
|
|
ds2LoopbackCommandSentToFarEnd,
|
|
facilityLoopback,
|
|
networkLoopback,
|
|
terminalLoopback,
|
|
manuallyCausedAbnormalCondition,
|
|
ethernetBridgeIsNewRootOfSpanningTree,
|
|
ethernetBridgeTopologyChange,
|
|
normalCondition,
|
|
embeddedOperationsChannelFailureLinkDown,
|
|
peerStateMismatch,
|
|
proceduralError,
|
|
improperRemoval,
|
|
duplicateNodeID,
|
|
blsrOutOfSync,
|
|
blsrMultiNodeTableUpdateCompleted,
|
|
protectionUnitNotAvailable,
|
|
performanceMonitorThresholdCrossingAlert,
|
|
protectionSwitch,
|
|
recoveryOrServiceProtectionActionHasBeenInitiated,
|
|
automaticSystemReset,
|
|
automaticUPSRSwitchCausedByAIS,
|
|
automaticUPSRSwitchCausedByLOP,
|
|
automaticUPSRSwitchCausedByUNEQ,
|
|
automaticUPSRSwitchCausedByPDI,
|
|
automaticUPSRSwitchCausedBySFBER,
|
|
automaticUPSRSwitchCausedBySDBER,
|
|
coldRestart,
|
|
forcedSwitchBackToWorking,
|
|
forcedSwitchBackToWorkingRing,
|
|
forcedSwitchBackToWorkingSpan,
|
|
forcedSwitchToProtection,
|
|
forcedSwitchToProtectionRing,
|
|
forcedSwitchToProtectionSpan,
|
|
workingFacilityOrEquipmentForcedToSwitchToProtectionPath,
|
|
initializationInitiated,
|
|
lockoutOfProtection,
|
|
lockoutOfProtectionRing,
|
|
lockoutOfProtectionSpan,
|
|
lockoutOfProtectionPath,
|
|
lockoutOfWorking,
|
|
lockoutOfWorkingRing,
|
|
lockoutOfWorkingSpan,
|
|
manualSystemReset,
|
|
manualSwitchToInternalClock,
|
|
manualSwitchToPrimaryReference,
|
|
manualSwitchToSecondReference,
|
|
manualSwitchToThirdReference,
|
|
manualSwitchToFourthReference,
|
|
manualSwitchToFifthReference,
|
|
manualSwitchToSixthReference,
|
|
manualSwitchBackToWorking,
|
|
manualSwitchBackToWorkingRing,
|
|
manualSwitchBackToWorkingSpan,
|
|
manualSwitchToProtection,
|
|
manualSwitchToProtectionRing,
|
|
manualSwitchToProtectionSpan,
|
|
manualSwitchOfWorkingFacilityOrEquipmentToProtectionPath,
|
|
powerfailRestart,
|
|
ringIsSquelchingTraffic,
|
|
softwareDownloadInProgress,
|
|
switchToInternalClock,
|
|
switchToPrimaryReference,
|
|
switchToSecondReference,
|
|
switchToThirdReference,
|
|
switchToFourthReference,
|
|
switchToFifthReference,
|
|
switchToSixthReference,
|
|
systemReboot,
|
|
switchedBackToWorking,
|
|
switchedToProtection,
|
|
warmRestart,
|
|
ringIsInWaitToRestoreState,
|
|
manualSwitchRequest,
|
|
forcedSwitchRequest,
|
|
lockoutSwitchRequest,
|
|
rmonHistoriesAndAlarmsResetReboot,
|
|
rmonThresholdCrossingAlarm,
|
|
alarmsSuppressedByUserCommand,
|
|
alarmsSuppressedForMaintenance,
|
|
switchingMatrixModuleFailure,
|
|
lanConnectionPolarityReversed,
|
|
autonomousPMReportMessageInhibited,
|
|
ioSlotToXCONCommunicationFailure,
|
|
stsPathTraceIdentifierMismatch,
|
|
nePowerFailureAtConnectorA,
|
|
nePowerFailureAtConnectorB,
|
|
freeMemoryOnCardVeryLow,
|
|
freeMemoryOnCardNearZero,
|
|
exerciseRequestOnRing,
|
|
exerciseRequestOnSpan,
|
|
squelchingPath,
|
|
extraTrafficPreempted,
|
|
farEndLockoutOfWorkingRing,
|
|
farEndLockoutOfWorkingSpan,
|
|
farEndLockoutOfProtectionRing,
|
|
farEndLockoutOfProtectionAllSpans,
|
|
farEndWorkingFacilityForcedToSwitchToProtectionRing,
|
|
farEndWorkingFacilityForcedToSwitchToProtectionSpan,
|
|
farEndManualSwitchOfWorkingFacilityToProtectionRing,
|
|
farEndManualSwitchOfWorkingFacilityToProtectionSpan,
|
|
farEndExercisingRing,
|
|
farEndExercisingSpan,
|
|
farEndBERThresholdPassedForSignalFailureRing,
|
|
farEndBERThresholdPassedForSignalFailureSpan,
|
|
farEndBERThresholdPassedForSignalDegradeRing,
|
|
farEndBERThresholdPassedForSignalDegradeSpan,
|
|
apsChannelFarEndProtectionLineSignalDegrade,
|
|
ringSwitchIsActiveOnTheEastSide,
|
|
ringSwitchIsActiveOnTheWestSide,
|
|
spanSwitchIsActiveOnTheEastSide,
|
|
spanSwitchIsActiveOnTheWestSide,
|
|
uniDirectionalFullPassThroughIsActive,
|
|
biDirectionalFullPassThroughIsActive,
|
|
kBytesPassThroughIsActive,
|
|
ringIsSegmented,
|
|
ringTopologyIsUnderConstruction,
|
|
lockoutOfProtectionAllSpans,
|
|
farEndOfFiberIsProvisionedWithDifferentRingID,
|
|
bothEndsOfFiberProvisionedAsEastOrBothAsWest,
|
|
autonomousMessagesInhibited,
|
|
trafficStormOnLANLANTemporarilyDisabled,
|
|
reptdbchgMessagesInhibited,
|
|
securityUserIDHasExpired,
|
|
partialFanFailure,
|
|
forcedSwitchRequestOnRing,
|
|
forcedSwitchRequestOnSpan,
|
|
lockoutSwitchRequestOnRing,
|
|
lockoutSwitchRequestOnSpan,
|
|
manualSwitchRequestOnRing,
|
|
manualSwitchRequestOnSpan,
|
|
communicationFailurePeerToPeerSlotControlBusA,
|
|
communicationFailurePeerToPeerSlotControlBusB,
|
|
controllerAToShelfSlotCommunicationFailure,
|
|
controllerBToShelfSlotCommunicationFailure,
|
|
interconnectionEquipmentFailureWorkingPayloadBus,
|
|
interconnectionEquipmentFailureProtectPayloadBus,
|
|
inhibitSwitchToProtectRequestOnEquipment,
|
|
inhibitSwitchToWorkingRequestOnEquipment,
|
|
exercisingRingSuccessfully,
|
|
exercisingSpanSuccessfully,
|
|
spanIsInWaitToRestoreState,
|
|
exerciseRequestOnRingFailed,
|
|
exerciseRequestOnSpanFailed,
|
|
farEndLockoutOfProtectionSpan,
|
|
manufacturingDataMemoryEEPROMFailure,
|
|
replaceableEquipmentOrUnitIsMissing,
|
|
softwareDownloadFailed,
|
|
extraTrafficPCADropped,
|
|
etherTxOversubscribed,
|
|
etherRxOverSubscribed,
|
|
etherTxExcessFlowCtrl,
|
|
etherRxExcessFlowCtrl,
|
|
transportLayerFailure,
|
|
etherTxUnderrun,
|
|
synchronizationReferenceFrequencyOutOfBounds,
|
|
ntpOrSntpHostFailure,
|
|
peerCardNotResponding,
|
|
alarmsAndEventsSuppressedForThisObject,
|
|
ds3FrameFormatMismatch,
|
|
timSectionTraceIdentifierMismatchFailure,
|
|
aisMultiplexSectionAlarmIndicationSignal,
|
|
rdiMultiplexSectionRemoteDefectOrAlarmIndication,
|
|
timHighOrderTraceIdentifierMismatchFailure,
|
|
aisAdministrationUnitAlarmIndicationSignal,
|
|
lopAdministrationUnitLossOfPointer,
|
|
slmfUnequippedHighOrderPathUnequipped,
|
|
slmfPLMHighOrderPathLabelMismatch,
|
|
rdiHighOrderRemoteDefectOrAlarmIndication,
|
|
lopTributaryUnitLossOfPointer,
|
|
aisTributaryUnitAlarmIndicationSignal,
|
|
slmfUnequippedLowOrderPathUnequipped,
|
|
slmfPLMLowOrderPathLabelMismatch,
|
|
timLowOrderTraceIdentifierMismatchFailure,
|
|
rfiLowOrderRemoteFailureOrAlarmIndication,
|
|
g811PrimaryReferenceClockTraceable,
|
|
g812TransitNodeClockTraceable,
|
|
g812LocalNodeClockTraceable,
|
|
g813SynchronousEquipmentTimingSourceTraceable,
|
|
e1LoopbackDueToFEACCommand,
|
|
e1LoopbackCommandSentToFarEnd,
|
|
e3LoopbackDueToFEACCommand,
|
|
farEndMultipleE1LOSDetectedOnE3,
|
|
farEndE1EqptFailNonServiceAffecting,
|
|
farEndE1EqptFailServiceAffecting,
|
|
farEndSingleE1LOS,
|
|
farEndE3EqptFailServiceAffecting,
|
|
e3LoopbackCommandSentToFarEnd,
|
|
farEndE3EqptFailNonServiceAffecting,
|
|
lowVoltBatteryA,
|
|
highVoltBatteryA,
|
|
lowVoltBatteryB,
|
|
highVoltBatteryB,
|
|
msspRingOutOfSync,
|
|
msspMultiNodeTableUpdateCompleted,
|
|
automaticSNCPSwitchCausedByAIS,
|
|
automaticSNCPSwitchCausedByLOP,
|
|
automaticSNCPSwitchCausedByUNEQ,
|
|
automaticSNCPSwitchCausedByPDI,
|
|
automaticSNCPSwitchCausedBySFBER,
|
|
automaticSNCPSwitchCausedBySDBER,
|
|
stmConcatenationError,
|
|
e3IdleCondition,
|
|
channelMSSPInconsistentAPSCode,
|
|
channelMSSPImproperAPSCodeAPS,
|
|
channelMSSPNodeIdMismatchAPS,
|
|
channelMSSPDefaultKAPS,
|
|
channelMSSPConnectionLossAPS,
|
|
minimumClockTraceableSDH,
|
|
lineIsInWaitToRestoreStateSDH,
|
|
berThresholdExceededForSignalDegradeHighOrder,
|
|
berThresholdExceededForSignalFailureHighOrder,
|
|
berThresholdExceededForSignalDegradeLowOrder,
|
|
berThresholdExceededForSignalFailureLowOrder,
|
|
failureToSwitchToProtectionHighOrderPath,
|
|
failureToSwitchToProtectionLowOrderPath,
|
|
a8b10bOutOfSync,
|
|
odukPMAlarmIndicationSignal,
|
|
otukAlarmIndicationSignal,
|
|
otukSMBackwardDefectIndication,
|
|
odukBackwardDefectIndication,
|
|
fecUncorrectedWord,
|
|
gccTerminationFailure,
|
|
otukIncomingAlignmentError,
|
|
odukLockedDefectPM,
|
|
lossOfMultiFrame,
|
|
odukOpenConnectionIndication,
|
|
payloadTypeIdentifierMismatch,
|
|
odukTrailTraceIdentifierMismatch,
|
|
otukTrailTraceIdentifierMismatch,
|
|
equipmentHighLaserBias,
|
|
equipmentHighLaserTemp,
|
|
equipmentHighLaserPeltier,
|
|
facilityHighRxPower,
|
|
equipmentHighTxPower,
|
|
equipmentHighTransceiverVoltage,
|
|
equipmentLowLaserBias,
|
|
equipmentLowLaserTemp,
|
|
equipmentLowLaserPeltier,
|
|
facilityLowRxPower,
|
|
equipmentLowTxPower,
|
|
equipmentLowTransceiverVoltage,
|
|
equipmentRxLocked,
|
|
equipmentSquelched,
|
|
equipmentTxLocked,
|
|
otukSignalFailure,
|
|
odukSignalFailure,
|
|
otukSignalDegrade,
|
|
odukSignalDegrade,
|
|
pluggablePortMissing,
|
|
pluggablePortRateMismatch,
|
|
pluggablePortSecurityCodeMismatch,
|
|
tciNotSelected,
|
|
tci1ClockFailure,
|
|
odukPMBackwardDefectIndication,
|
|
odukTCM1BackwardDefectIndication,
|
|
odukTCM2BackwardDefectIndication,
|
|
equipmentHighRxTemperature,
|
|
equipmentLowRxTemperature,
|
|
tci2ClockFailure,
|
|
equipmentWavelengthMismatch,
|
|
dspCommunicationFailure,
|
|
dspFailure,
|
|
laserApproachingEndOfLife,
|
|
crossconnectLoopback,
|
|
adminLogoutOfUser,
|
|
userLockedOut,
|
|
adminLockoutOfUser,
|
|
adminLockoutClear,
|
|
invalidLoginUsername,
|
|
securityInvalidLoginPassword,
|
|
securityInvalidLoginLockedOut,
|
|
securityInvalidLoginAlreadyLoggedOn,
|
|
loginOfUser,
|
|
automaticLogoutOfIdleUser,
|
|
logoutOfUser,
|
|
firewallHasBeenDisabled,
|
|
connectionEquipmentMismatch,
|
|
disableInactiveUser,
|
|
disableInactiveClear,
|
|
batteryFailure,
|
|
extremeHighVolt,
|
|
extremeLowVolt,
|
|
highVolt,
|
|
lowVolt,
|
|
suspendUser,
|
|
suspendUserClear,
|
|
lineDccTerminationFailure,
|
|
multiplexSectionDccTerminationFailure,
|
|
gigaBitEthernetOutOfSync,
|
|
sequenceMismatch,
|
|
lossOfAlignment,
|
|
outOfUseByAdministrativeCommand,
|
|
outOfUseTransportFailure,
|
|
vcatGroupDown,
|
|
vcatGroupDegraded,
|
|
vcatGroupIncomplete,
|
|
alarmIndicationSignalInTX,
|
|
remoteAlarmIndicationInTX,
|
|
kByteAPSChannelFailure,
|
|
apsInvalidMode,
|
|
ipAddressAlreadyInUseWithinTheSameDccArea,
|
|
nodeNameInUseWithinTheSameDccArea,
|
|
rearPanelEthernetLinkRemoved,
|
|
manualSwitchToProtectResultedInNoTrafficSwitch,
|
|
manualSwitchBackToWorkingResultedInNoTrafficSwitch,
|
|
forcedSwitchToProtectResultedInNoTrafficSwitch,
|
|
forcedSwitchBackToWorkingResultedInNoTrafficSwitch,
|
|
duplicateSerialNumberDetectedOnAPluggableEntity,
|
|
lossOfSignalForOpticalChannel,
|
|
encapsulationMismatchPath,
|
|
encapsulationMismatchVT,
|
|
encapsulationMismatchHighOrderPath,
|
|
encapsulationMismatchLowOrderPath,
|
|
gfpUserPayloadMismatch,
|
|
gfpFibreChannelDistanceExtensionMismatch,
|
|
gfpFibreChannelDistanceExtensionBufferStarvation,
|
|
gfpFibreChannelDistanceExtensionCreditStarvation,
|
|
gfpClientSignalFailDetected,
|
|
gfpLossOfFrameDelineation,
|
|
gfpExtensionHeaderMismatch,
|
|
lcasVcgMemberTxSideInAddState,
|
|
lcasVcgMemberTxSideInDnuState,
|
|
lcasControlWordCrcCheckFailure,
|
|
lcasVcgMemberRxSideInFailState,
|
|
signalLossOnDataInterface,
|
|
synchronizationLossOnDataInterface,
|
|
portFAIL,
|
|
unreachablePortTargetPower,
|
|
portAddPowerDegradeLow,
|
|
portAddPowerDegradeHigh,
|
|
portAddPowerFailLow,
|
|
portAddPowerFailHigh,
|
|
automaticWdmAnsFinished,
|
|
incomingOverheadSignalAbsent,
|
|
opticalSafetyRemoteInterlockOn,
|
|
automaticPowerControlCorrectionSkipped,
|
|
apcCannotSetValueDueToRangeLimits,
|
|
farEndManualSwitchBackToWorkingSpan,
|
|
farEndForcedSwitchBackToWorkingSpan,
|
|
universalTransponderModuleHardwareFailure,
|
|
universalTransponderModuleCommunicationFailure,
|
|
pluginModuleRangeSettingsMismatch,
|
|
automaticPowerControlTerminatedOnManualRequest,
|
|
oduk1AlarmIndicationSignal,
|
|
oduk2AlarmIndicationSignal,
|
|
oduk3AlarmIndicationSignal,
|
|
oduk4AlarmIndicationSignal,
|
|
temperatureReadingMismatchBetweenSCCards,
|
|
voltageReadingMismatchBetweenSCCards,
|
|
alarmsSuppressedonOutOfGroupVcatMember,
|
|
blsrSoftwareVersionMismatch,
|
|
optimized1Plus1ApsPrimaryFacility,
|
|
optimized1Plus1ApsPrimarySectionMismatch,
|
|
optimized1Plus1ApsInvalidPrimarySection,
|
|
compositeClockHighLineVoltage,
|
|
berThresholdExceededForSignalDegradeVt,
|
|
berThresholdExceededForSignalFailureVt,
|
|
spanLengthOutOfRange,
|
|
idleSignalCondition,
|
|
idleSignalConditionInTx,
|
|
vtPathTraceIdentifierMismatch,
|
|
lossOfFrameInTX,
|
|
provisioningMismatch,
|
|
sectionTraceIdentifierMismatch,
|
|
regeneratorSectionTraceIdentifierMismatch,
|
|
switchingMatrixModuleFailureWorking,
|
|
switchingMatrixModuleFailureProtect,
|
|
slotCommunicationDisabled,
|
|
sessionTimeLimitExpired,
|
|
userPasswordChangeRequired,
|
|
isisAdjacencyFailure,
|
|
msspSoftwareVersionMismatch,
|
|
remoteAuthenticationFailSeeAuditLog,
|
|
ringIsSquelchingStsTraffic,
|
|
ringIsSquelchingVtTraffic,
|
|
archiveOfAuditLogFailed,
|
|
rprWrapped,
|
|
shelfCommunicationFailure,
|
|
duplicatedShelfIdentifier,
|
|
softwareMismatch,
|
|
lmpFailure,
|
|
opticalTerminationIncomplete,
|
|
forwardDefectIndication,
|
|
payloadMissingIndication,
|
|
spanMeasurementCannotBePerformed,
|
|
ringIsSquelchingHighOrderTraffic,
|
|
ringIsSquelchingLowOrderTraffic,
|
|
badPacketCountExceedsThreshold,
|
|
linkLayerKeepAliveFailure,
|
|
autonegotiationRemoteFailureIndication,
|
|
trailSignalFail,
|
|
ds1LoopbackCommandSentToFarEnd,
|
|
multiplexSectionSignalDegraded,
|
|
multiplexSectionExcessiveErrors,
|
|
highOrderPathSignalDegraded,
|
|
highOrderPathExcessiveErrors,
|
|
lowOrderPathSignalDegraded,
|
|
lowOrderPathExcessiveErrors,
|
|
regeneratorSectionDccTerminationFailure,
|
|
networkMemoryPoolLow,
|
|
ospfRoutingTableOverflow,
|
|
autoLaserShutdownDisabled,
|
|
rprProtectionIsActive,
|
|
maxRPRStationNumberExceeded,
|
|
rprProtectionConfigurationMismatched,
|
|
reservedBandwidthLinkRateExceededOnRinglet0,
|
|
reservedBandwidthLinkRateExceededOnRinglet1,
|
|
rprInterfaceInPassThroughMode,
|
|
rprPeerNodeIsMissing,
|
|
rprRiFailure,
|
|
rprSignalFailure,
|
|
rprSignalDegrade,
|
|
interlinkFailure,
|
|
apcWrongGain,
|
|
rprSpanMismatch,
|
|
efmRemoteFaultIndicationCriticalEvent,
|
|
efmRemoteFaultIndicationDyingGasp,
|
|
efmRemoteFaultIndicationLinkFault,
|
|
efmLinkMonitoringErroredSymbolPeriodEvent,
|
|
efmLinkMonitoringErroredFrameEvent,
|
|
efmLinkMonitoringErroredFramePeriodEvent,
|
|
efmLinkMonitoringErroredFrameSecondsSummary,
|
|
efmRemoteLoopbackRequestFailed,
|
|
fastAutomaticProtectionSwitching,
|
|
fastAutomaticProtectionSwitchingConfigMismatch,
|
|
lcasSinkGroupError,
|
|
lcasVcgMemberRxSideInDnuState,
|
|
fcDistanceExtFuncNotEstablished,
|
|
nonCiscoPPMInserted,
|
|
unqualifiedPPMInserted,
|
|
ftaMismatch,
|
|
cardPortsUnableToProvideProtection,
|
|
lmpSignalDegrade,
|
|
lmpSignalFailure,
|
|
lmpUnallocatedDataLink,
|
|
frontPortLinkLoss,
|
|
bertEnbl,
|
|
bertSyncFail,
|
|
workQueueFull,
|
|
equipmentPowerFailureAtConnectorA,
|
|
equipmentPowerFailureAtConnectorB,
|
|
equipmentPowerFailureAtReturnConnectorA,
|
|
equipmentPowerFailureAtReturnConnectorB,
|
|
ospfHelloFail,
|
|
openIOSlots,
|
|
lossOfClockFromMateShelfController,
|
|
virtualLanAlarmIndicationSignal,
|
|
dcuLossFailure,
|
|
ochncMaintenance,
|
|
ramanLaserShutdown,
|
|
losOfRamanSignal,
|
|
mcastMacTableFull,
|
|
multicastMacAddressAliasing,
|
|
ramanPwrProtOn,
|
|
cppPeerNotResponding,
|
|
voaControlLoopDisableDueToExcessiveCounterPropagationLight,
|
|
wizardIsRunning,
|
|
ramanGainNotReached,
|
|
localFault,
|
|
remoteFault,
|
|
efmRemoteLoopbackConfigured,
|
|
efmPeerMissing,
|
|
eqptDegrade,
|
|
excessiveBackPropagation,
|
|
remoteMaintenanceEndPointIsDown,
|
|
crossConnectedCFMService,
|
|
cfmLoop,
|
|
cfmConfigurationError,
|
|
outOfChannelGroupBundle,
|
|
repNeighborAdjacencyFailure,
|
|
repLinkFlapping,
|
|
faultInREPSegment,
|
|
primaryREPEdgePortElected,
|
|
secondaryREPEdgePortElected,
|
|
stcnREPGenerated,
|
|
vlbREPActivated,
|
|
vlbREPTriggerSoakingDelayActive,
|
|
pprForwardDefectIndication,
|
|
pprBackwardDefectIndication,
|
|
pprCoordinatedMaintenance,
|
|
pprTriggerThresholdBERExceeded,
|
|
wanSyncloss,
|
|
laserShutdownDueToWavelengthDrift,
|
|
manualLaserRestart,
|
|
laserShutdownDueToNonCiscoPPMInserted,
|
|
ethernetOSCTerminationFailure,
|
|
enhancedRemoteFailureIndicationPathServer,
|
|
enhancedRemoteFailureIndicationPathConnectivity,
|
|
enhancedRemoteFailureIndicationPathPayload,
|
|
securityIntrusionDetPwd,
|
|
securityIntrusionDetUser,
|
|
backPanelFacilityLoopback,
|
|
backPanelTerminalLoopback,
|
|
trunkPayloadTypeMismatch,
|
|
invalidMuxponderConfiguration,
|
|
coolingProfileMismatch,
|
|
trunkOduAlarmIndicationSignal,
|
|
companionCardMissing,
|
|
masterKeyExchangeFailed,
|
|
powerConsumptionLimitHasCrossed,
|
|
controlPlaneUnverifiedClearedAlarmsPresent,
|
|
unitHighTemperature,
|
|
overTemperatureUnitProtected,
|
|
seqMismatchCount,
|
|
keyProgramOnAlteraFpgaFailed,
|
|
duplicateNodeControllerDetected,
|
|
restorationInProg,
|
|
ramanPumpsCalibrationProcedureIsRunning,
|
|
ramanPumpsCalibrationIsScheduledToRunInTheNextMinutes,
|
|
odukTCM1AlarmIndicationSignal,
|
|
odukTCM2AlarmIndicationSignal,
|
|
odukLockedDefectTCM1,
|
|
odukLockedDefectTCM2,
|
|
otukLossOfFrame,
|
|
odukOpenConnectionIndicationTCM1,
|
|
odukOpenConnectionIndicationTCM2,
|
|
odukTrailTraceIdentifierMismatchTCM1,
|
|
odukTrailTraceIdentifierMismatchTCM2,
|
|
odukSignalFailureTCM1,
|
|
odukSignalFailureTCM2,
|
|
odukSignalDegradeTCM1,
|
|
odukSignalDegradeTCM2,
|
|
lossOfChannel,
|
|
fecMismatch,
|
|
timSectionMonitorTraceIdentifierMismatchFailure,
|
|
automaticLaserShutdown,
|
|
shutterInsertionLossVariationDegradeLow,
|
|
opticalChannelDeactivationFailure,
|
|
shutterInsertionLossVariationDegradeHigh,
|
|
networkTopologyIncomplete,
|
|
pluginModuleCommunicationFailure,
|
|
opticalNetworkTypeMismatch,
|
|
forcedSwitchToPrimaryReference,
|
|
forcedSwitchToSecondReference,
|
|
forcedSwitchToThirdReference,
|
|
forcedSwitchToInternalClock,
|
|
industrialHighTemperature,
|
|
opticalPowerDegradeLow,
|
|
automaticPowerControlFailure,
|
|
opticalPowerDegradeHigh,
|
|
automaticPowerControlDisabled,
|
|
opticalPowerFailureLow,
|
|
ringIdMismatch,
|
|
opticalPowerFailureHigh,
|
|
lossOfContinuity,
|
|
variableOpticalAttenuatorDegradeLow,
|
|
variableOpticalAttenuatorDegradeHigh,
|
|
variableOpticalAttenuatorFailureLow,
|
|
variableOpticalAttenuatorFailureHigh,
|
|
laserBiasDegrade,
|
|
laserBiasFailure,
|
|
laserTemperatureDegrade,
|
|
opticalAmplifierGainDegradeLow,
|
|
opticalAmplifierGainDegradeHigh,
|
|
opticalAmplifierGainFailureLow,
|
|
opticalAmplifierGainFailureHigh,
|
|
opticalChannelConnectionFailure,
|
|
opticalChannelIncomplete,
|
|
opticalChannelActivationFailure,
|
|
laserAutoPowerReduction,
|
|
caseTemperatureDegrade,
|
|
fiberTemperatureDegrade,
|
|
shutterOpen,
|
|
awgTemperatureDegrade,
|
|
awgTemperatureFailure,
|
|
awgOverTemperature,
|
|
opticalAmplifierInitialization,
|
|
awgWarmUp,
|
|
incSigloss,
|
|
incSyncloss,
|
|
incGfpOutOfFrame,
|
|
incGfpSigLoss,
|
|
incGfpSyncLoss,
|
|
bridgeAndRollHasOccurred,
|
|
bridgeAndRollIsPendingAValidSignal,
|
|
clockBusFailureTscA,
|
|
clockBusFailureTscB,
|
|
waitToRestore,
|
|
extremeHighVoltBatteryA,
|
|
extremeLowVoltBatteryA,
|
|
extremeHighVoltBatteryB,
|
|
extremeLowVoltBatteryB,
|
|
iosConfigCopyFailed,
|
|
iosConfigCopyInProgress,
|
|
iosConfigCopySuccess,
|
|
signalingUnableToSetupCircuit,
|
|
errorInStartupConfig,
|
|
noStartupConfig,
|
|
needToSaveRunningConfig,
|
|
invalidAlarm,
|
|
rsvpHelloFSMToNeighborDown,
|
|
securityInvalidLoginUsername,
|
|
databaseBackupFailed,
|
|
databaseRestoreFailed,
|
|
lmpHelloFSMToControlChannelDown,
|
|
lmpNeighborDiscoveryHasFailed,
|
|
auditLog80PercentFull,
|
|
moduleCommunicationFailure,
|
|
auditLog100PercentFullOldestRecordsWillBeLost,
|
|
standbyDatabaseOutOfSync,
|
|
redundantPowerCapabilityLost,
|
|
lofAdministrationUnitLossOfMultiFrame,
|
|
sdhSpanIsInWaitToRestoreState,
|
|
berThresholdExceededForSignalDegradeLine,
|
|
berThresholdExceededForSignalDegradePath,
|
|
berThresholdExceededForSignalFailureLine,
|
|
berThresholdExceededForSignalFailurePath,
|
|
unauthorizedIncomingSignalingRequest
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notifications for Cisco ONS 15454"
|
|
::= { cerent454Groups 30 }
|
|
|
|
-- This definition of group will move to a cerentCommon modules
|
|
-- eventually.
|
|
|
|
cerent454CommonGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- cerentNotificationCategory,
|
|
cerent454EnableNotification,
|
|
cerent454NodeTime,
|
|
cerent454SentNotifications,
|
|
cerent454LastChangeTime,
|
|
cerent454MultishelfEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects for storing all the current alarms"
|
|
::= { cerent454Groups 40 }
|
|
|
|
-- This group covers for threshold display and TCA trap
|
|
|
|
cerentThresholdGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
cerent454ThresholdMonitorType,
|
|
cerent454ThresholdLocation,
|
|
cerent454ThresholdPeriod,
|
|
cerent454ThresholdSetValue,
|
|
cerent454ThresholdCurrentValue,
|
|
cerent454ThresholdDetectType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The objects for storing all the current alarms"
|
|
::= { cerent454Groups 50 }
|
|
|
|
event454DeprecatedGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
securityInvalidLoginUsernameSeeAuditTrail
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The notifications for Cisco ONS 15454 that have been deprecated"
|
|
::= { cerent454Groups 60 }
|
|
|
|
reportedAlarm454Group OBJECT-GROUP
|
|
OBJECTS {
|
|
cerent454ReportedAlarmCount,
|
|
cerent454ReportedAlarmObjectType,
|
|
cerent454ReportedAlarmSlotNumber,
|
|
cerent454ReportedAlarmPortNumber,
|
|
cerent454ReportedAlarmObjectIndex,
|
|
cerent454ReportedAlarmType,
|
|
cerent454ReportedAlarmTimeStamp,
|
|
cerent454ReportedAlarmObjectName,
|
|
cerent454ReportedAlarmAdditionalInfo,
|
|
cerent454ReportedAlarmSeverity,
|
|
cerent454ReportedAlarmStatus,
|
|
cerent454ReportedAlarmServiceAffecting
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group for reported alarm objects"
|
|
::= { cerent454Groups 80 }
|
|
|
|
|
|
-- the compliance specification for agent developers
|
|
|
|
cerent454BasicCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The basic implementation requirements for Cisco ONS 15454 MIB"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
node454Group,
|
|
event454Group
|
|
}
|
|
::= { cerent454Compliance 10 }
|
|
|
|
END
|