- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
6086 lines
210 KiB
Text
6086 lines
210 KiB
Text
CAMBIUM-PTP650-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Integer32, IpAddress,
|
|
enterprises
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
InetAddress, InetAddressType
|
|
FROM INET-ADDRESS-MIB;
|
|
|
|
cambium MODULE-IDENTITY
|
|
LAST-UPDATED "201502060443Z"
|
|
ORGANIZATION "Cambium Networks Ltd."
|
|
CONTACT-INFO
|
|
"Post: Simon Whitaker
|
|
Cambium Networks Ltd.
|
|
Unit B2,
|
|
Linhay Business Park,
|
|
Eastern Road,
|
|
Ashburton,
|
|
Devon.
|
|
TQ13 7UP
|
|
United Kingdom
|
|
Phone: +44 (0) 1364 655 500
|
|
Email: simon.whitaker@cambiumnetworks.com"
|
|
DESCRIPTION
|
|
"MIB for non-line-of-sight (NLOS) wireless ethernet bridge."
|
|
REVISION "201502060443Z"
|
|
DESCRIPTION
|
|
"PTP650-01-40:
|
|
Added Second Data Service attributes to support a second data path over
|
|
wireless link.
|
|
Added support for Cable Diagnostics.
|
|
Added IEEE 1588 Transparent Clock source port and Transparent Clock source
|
|
alarm attributes."
|
|
REVISION "201406181412Z"
|
|
DESCRIPTION
|
|
"PTP650-01-20:
|
|
Added TDM group and NIDU attributes to support the telecomms interfaces.
|
|
Added Router Protocols group to support Microwave Adaptive Bandwidth (MAB).
|
|
Added support for Out-Of-Band Remote Management, and for mute and enable
|
|
transmission. Renamed 'ethernet bridging' attributes to 'data bridging'.
|
|
Made more SyncE attributes writable."
|
|
REVISION "201402211503Z"
|
|
DESCRIPTION
|
|
"PTP650-01-10:
|
|
Added Synchronous Ethernet (SyncE) and IEEE 1588 Transparent Clock.
|
|
Support PTP650s. Clarified localPacketFiltering, regulatoryBand,
|
|
TDD Sync status & alarm. TX power max increased to 30dBm.
|
|
Modified the bit assignments of enabledDiagnosticAlarms to combine
|
|
the various status & warning bits for the main PSU, Aux & SFP ports
|
|
into a single portState bit."
|
|
REVISION "201308021028Z"
|
|
DESCRIPTION "PTP650-01-00: Initial revision."
|
|
::= { enterprises 17713 }
|
|
|
|
-- Groups in cambium
|
|
ptp OBJECT IDENTIFIER ::= { cambium 1 }
|
|
ptmp OBJECT IDENTIFIER ::= { cambium 2 }
|
|
ptp650 OBJECT IDENTIFIER ::= { cambium 7 }
|
|
|
|
-- Groups in ptp650
|
|
dfs OBJECT IDENTIFIER ::= { ptp650 3 }
|
|
bridge OBJECT IDENTIFIER ::= { ptp650 4 }
|
|
configuration OBJECT IDENTIFIER ::= { ptp650 5 }
|
|
ethernet OBJECT IDENTIFIER ::= { ptp650 6 }
|
|
tDM OBJECT IDENTIFIER ::= { ptp650 7 }
|
|
license OBJECT IDENTIFIER ::= { ptp650 8 }
|
|
management OBJECT IDENTIFIER ::= { ptp650 9 }
|
|
phyControl OBJECT IDENTIFIER ::= { ptp650 10 }
|
|
phyStatus OBJECT IDENTIFIER ::= { ptp650 12 }
|
|
alarms OBJECT IDENTIFIER ::= { ptp650 13 }
|
|
smtp OBJECT IDENTIFIER ::= { ptp650 15 }
|
|
snmpControl OBJECT IDENTIFIER ::= { ptp650 16 }
|
|
sntp OBJECT IDENTIFIER ::= { ptp650 17 }
|
|
reset OBJECT IDENTIFIER ::= { ptp650 18 }
|
|
versions OBJECT IDENTIFIER ::= { ptp650 19 }
|
|
pubStats OBJECT IDENTIFIER ::= { ptp650 20 }
|
|
encryption OBJECT IDENTIFIER ::= { ptp650 22 }
|
|
tDDControl OBJECT IDENTIFIER ::= { ptp650 23 }
|
|
aAAControl OBJECT IDENTIFIER ::= { ptp650 25 }
|
|
syslogControl OBJECT IDENTIFIER ::= { ptp650 24 }
|
|
routerProtocols OBJECT IDENTIFIER ::= { ptp650 26 }
|
|
cableDiagnostics OBJECT IDENTIFIER ::= { ptp650 27 }
|
|
supplementary OBJECT IDENTIFIER ::= { ptp650 96 }
|
|
ptpGroups OBJECT IDENTIFIER ::= { ptp650 98 }
|
|
ptpTraps OBJECT IDENTIFIER ::= { ptp650 99 }
|
|
ptpTrapPrefix OBJECT IDENTIFIER ::= { ptpTraps 0 }
|
|
|
|
-- Compliance information
|
|
--
|
|
ptpCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the Cambium PTP MIB"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { dfsGroup
|
|
, bridgeGroup
|
|
, configurationGroup
|
|
, ethernetGroup
|
|
, tDMGroup
|
|
, licenseGroup
|
|
, managementGroup
|
|
, phyControlGroup
|
|
, phyStatusGroup
|
|
, alarmsGroup
|
|
, smtpGroup
|
|
, snmpControlGroup
|
|
, sntpGroup
|
|
, resetGroup
|
|
, versionsGroup
|
|
, pubStatsGroup
|
|
, encryptionGroup
|
|
, tDDControlGroup
|
|
, aAAControlGroup
|
|
, syslogControlGroup
|
|
, routerProtocolsGroup
|
|
, cableDiagnosticsGroup
|
|
, supplementaryGroup
|
|
, notificationsGroup
|
|
}
|
|
::= { ptp650 97 }
|
|
|
|
dfsGroup OBJECT-GROUP
|
|
OBJECTS { dfsTableNumber
|
|
, extendedSpectrumScanning
|
|
, dfsMeans
|
|
, dfsNineNinePointNinePercentiles
|
|
, dfsPeaks
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The dfs object group."
|
|
::= { ptpGroups 3 }
|
|
|
|
bridgeGroup OBJECT-GROUP
|
|
OBJECTS { localPacketFiltering
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The bridge object group."
|
|
::= { ptpGroups 4 }
|
|
|
|
configurationGroup OBJECT-GROUP
|
|
OBJECTS { iPv4Address
|
|
, subnetMask
|
|
, gatewayIPAddress
|
|
, targetMACAddress
|
|
, masterSlaveMode
|
|
, maximumTransmitPower
|
|
, antennaGain
|
|
, cableLoss
|
|
, eIRP
|
|
, channelBandwidth
|
|
, linkName
|
|
, siteName
|
|
, accessMethod
|
|
, groupID
|
|
, iPv6Address
|
|
, iPVersion
|
|
, iPv6AutoConfiguredLinkLocalAddress
|
|
, iPv6PrefixLength
|
|
, iPv6GatewayAddress
|
|
, remoteInternetAddressType
|
|
, remoteInternetAddress
|
|
, subbandLowestFrequency
|
|
, subbandHighestFrequency
|
|
, enableTransmission
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The configuration object group."
|
|
::= { ptpGroups 5 }
|
|
|
|
ethernetGroup OBJECT-GROUP
|
|
OBJECTS { mainPSUPortAutoNegotiation
|
|
, mainPSUPortAutoNegAdvertisement
|
|
, mainPSUPortAutoMdix
|
|
, mainPSUPortStatus
|
|
, mainPSUPortSpeedAndDuplex
|
|
, dataPortWirelessDownAlert
|
|
, useVLANForManagementInterfaces
|
|
, vLANManagementPriority
|
|
, vLANManagementVID
|
|
, auxPortStatus
|
|
, auxPortSpeedAndDuplex
|
|
, ethernetPriorityTableNumber
|
|
, l2CPPriorityTableNumber
|
|
, iPDSCPPriorityTableNumber
|
|
, mPLSTCPriorityTableNumber
|
|
, managementPortWirelessDownAlert
|
|
, qOSPriorityScheme
|
|
, unknownNetworkPriorityQueueMapping
|
|
, dSCPManagementPriority
|
|
, dataBridgingStatus
|
|
, mainPSUPortAllocation
|
|
, auxPortAllocation
|
|
, sFPPortAllocation
|
|
, dataPortPauseFrames
|
|
, sFPPortAutoNegotiation
|
|
, sFPPortAutoNegAdvertisement
|
|
, sFPPortAutoMdix
|
|
, sFPPortStatus
|
|
, sFPPortSpeedAndDuplex
|
|
, auxPortPowerOverEthernetOutput
|
|
, auxPortPowerOverEthernetOutputStatus
|
|
, syncETracking
|
|
, syncEEquipmentClock
|
|
, mainPSUPortQLRxOverwrite
|
|
, mainPSUPortSSMTx
|
|
, sFPPortSSMTx
|
|
, auxPortSSMTx
|
|
, syncETrackingState
|
|
, mainPSUPortQLRx
|
|
, auxPortQLRx
|
|
, sFPPortQLRx
|
|
, mainPSUPortQLTx
|
|
, auxPortQLTx
|
|
, sFPPortQLTx
|
|
, mainPSUPortSyncEMasterSlaveStatus
|
|
, auxPortSyncEMasterSlaveStatus
|
|
, sFPPortSyncEMasterSlaveStatus
|
|
, mainPSUPortGigabitMasterSlaveStatus
|
|
, auxPortGigabitMasterSlaveStatus
|
|
, sFPPortGigabitMasterSlaveStatus
|
|
, transparentClock
|
|
, transparentClockVLAN
|
|
, transparentClockVID
|
|
, mainPSUPortAcceptedQLRx
|
|
, auxPortAcceptedQLRx
|
|
, sFPPortAcceptedQLRx
|
|
, mainPSUPortSyncERxStatus
|
|
, auxPortSyncERxStatus
|
|
, sFPPortSyncERxStatus
|
|
, nIDULanPortStatus
|
|
, nIDULanPortSpeedAndDuplex
|
|
, oOBPriorityQueueMapping
|
|
, nIDULanPortAutoNegotiation
|
|
, nIDULanPortAutoNegAdvertisement
|
|
, nIDULanPortAutoMdix
|
|
, nIDULanPortGigabitMasterSlaveStatus
|
|
, txMABFrames
|
|
, managementNetworkAccessEnabled
|
|
, secondDataPortPauseFrames
|
|
, secondDataBridgingStatus
|
|
, transparentClockPort
|
|
, ethernetPriorityQueueMapping
|
|
, l2CPPriorityQueueMapping
|
|
, iPDSCPPriorityQueueMapping
|
|
, mPLSTCPriorityQueueMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The ethernet object group."
|
|
::= { ptpGroups 6 }
|
|
|
|
tDMGroup OBJECT-GROUP
|
|
OBJECTS { tDMInterfaceControl
|
|
, tDMInterfaceStatus
|
|
, tDMEnabledChannels
|
|
, tdmTableNumber
|
|
, tDMConfigurationMismatch
|
|
, lowestTDMModulationMode
|
|
, tDMChannelStatus
|
|
, tDMChannelLineCode
|
|
, tDMChannelCableLength
|
|
, tDMChannelLoopback
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The tDM object group."
|
|
::= { ptpGroups 7 }
|
|
|
|
licenseGroup OBJECT-GROUP
|
|
OBJECTS { regulatoryBand
|
|
, productVariant
|
|
, productName
|
|
, frequencyVariant
|
|
, sNMPv3Enable
|
|
, licenseVersion
|
|
, licenseUnitSerialNumber
|
|
, licenseIssueNumber
|
|
, licenseCountry
|
|
, licenseNumberOfRegulatoryBands
|
|
, licenseBandwidthCap
|
|
, licenseEncryption
|
|
, licenseSecurityLevel
|
|
, licenseGroupAccess
|
|
, licenseOOBManagementSupport
|
|
, licenseSFPPortSupport
|
|
, licenseAuxiliaryPortSupport
|
|
, licenseCapacity
|
|
, licenseMaxNumberOfTDMChannels
|
|
, licenseIEEE1588Support
|
|
, licenseSyncESupport
|
|
, licenseIPv6Support
|
|
, licenseMinimumFirmwareVersion
|
|
, licenseFullCapabilityTrialStatus
|
|
, licenseRemainingTrialPeriod
|
|
, licenseRemainingTrialPeriodAlarm
|
|
, capacityVariantMismatch
|
|
, licenseTDDSyncSupport
|
|
, licenseMaxLinkRange
|
|
, licenseTrialPeriod
|
|
, licenseRARSupport
|
|
, licenseRegulatoryBandsList
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The license object group."
|
|
::= { ptpGroups 8 }
|
|
|
|
managementGroup OBJECT-GROUP
|
|
OBJECTS { targetRange
|
|
, rangingMode
|
|
, installStatus
|
|
, installArmState
|
|
, tFTPServerPortNumber
|
|
, tFTPSoftwareUpgradeFileName
|
|
, tFTPStartSoftwareUpgrade
|
|
, tFTPSoftwareUpgradeStatus
|
|
, tFTPSoftwareUpgradeStatusText
|
|
, tFTPSoftwareUpgradeStatusAdditionalText
|
|
, hTTPAccessEnabled
|
|
, telnetAccessEnabled
|
|
, hTTPPortNumber
|
|
, hTTPSPortNumber
|
|
, telnetPortNumber
|
|
, hTTPSAccessEnabled
|
|
, tFTPServerInternetAddressType
|
|
, tFTPServerInternetAddress
|
|
, lowestDataModulationMode
|
|
, lowestSecondDataModulationMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The management object group."
|
|
::= { ptpGroups 9 }
|
|
|
|
phyControlGroup OBJECT-GROUP
|
|
OBJECTS { linkSymmetry
|
|
, userConfiguredMaxModulationMode
|
|
, linkModeOptimization
|
|
, txColorCode
|
|
, rxColorCode
|
|
, remoteMaximumTransmitPower
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The phyControl object group."
|
|
::= { ptpGroups 10 }
|
|
|
|
phyStatusGroup OBJECT-GROUP
|
|
OBJECTS { linkLoss
|
|
, receivePower
|
|
, vectorError
|
|
, transmitPower
|
|
, receiveChannel
|
|
, transmitChannel
|
|
, receiveFreqMHz
|
|
, transmitFreqMHz
|
|
, signalStrengthRatio
|
|
, receiveFreqKHz
|
|
, transmitFreqKHz
|
|
, rawReceivePower
|
|
, range
|
|
, receiveModulationMode
|
|
, transmitModulationMode
|
|
, searchState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The phyStatus object group."
|
|
::= { ptpGroups 12 }
|
|
|
|
alarmsGroup OBJECT-GROUP
|
|
OBJECTS { unitOutOfCalibration
|
|
, incompatibleRegulatoryBands
|
|
, noWirelessChannelAvailable
|
|
, wirelessLinkDisabledWarning
|
|
, mainPSUPortDisabledWarning
|
|
, sFPError
|
|
, mainPSUPortConfigurationMismatch
|
|
, incompatibleMasterAndSlave
|
|
, tDDSynchronizationStatus
|
|
, auxPortDisabledWarning
|
|
, tDDSynchronizationAlarm
|
|
, linkModeOptimizationMismatch
|
|
, auxPortConfigurationMismatch
|
|
, secureModeAlarm
|
|
, dataBridgingStatusAlarm
|
|
, sFPPortDisabledWarning
|
|
, sFPPortConfigurationMismatch
|
|
, maxLinkRangeExceeded
|
|
, nIDULanPortDisabledWarning
|
|
, nIDULanPortConfigurationMismatch
|
|
, portAllocationMismatch
|
|
, secondDataBridgingStatusAlarm
|
|
, transparentClockSourcePortAlarm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The alarms object group."
|
|
::= { ptpGroups 13 }
|
|
|
|
smtpGroup OBJECT-GROUP
|
|
OBJECTS { sMTPEmailAlert
|
|
, sMTPServerPortNumber
|
|
, sMTPSourceEmailAddress
|
|
, sMTPDestinationEmailAddress
|
|
, sMTPEnabledMessages
|
|
, sMTPServerInternetAddressType
|
|
, sMTPServerInternetAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The smtp object group."
|
|
::= { ptpGroups 15 }
|
|
|
|
snmpControlGroup OBJECT-GROUP
|
|
OBJECTS { sNMPPortNumber
|
|
, sNMPCommunityString
|
|
, sNMPTrapTableNumber
|
|
, sNMPTrapVersion
|
|
, sNMPEnabledTraps
|
|
, enabledDiagnosticAlarms
|
|
, sNMPSendAllTrapsAtStartup
|
|
, sNMPTrapPortNumber
|
|
, sNMPTrapInternetAddressType
|
|
, sNMPTrapInternetAddress
|
|
, sNMPTrapReceiverEnabled
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The snmpControl object group."
|
|
::= { ptpGroups 16 }
|
|
|
|
sntpGroup OBJECT-GROUP
|
|
OBJECTS { sNTPState
|
|
, sNTPPollInterval
|
|
, sNTPSync
|
|
, sNTPLastSync
|
|
, systemClock
|
|
, timeZone
|
|
, daylightSaving
|
|
, sNTPPrimaryServer
|
|
, sNTPPrimaryServerDeadTime
|
|
, sNTPServerRetries
|
|
, sNTPServerTimeout
|
|
, sNTPServerTableNumber
|
|
, sNTPServerPortNumber
|
|
, sNTPServerStatus
|
|
, sNTPServerInternetAddressType
|
|
, sNTPServerInternetAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The sntp object group."
|
|
::= { ptpGroups 17 }
|
|
|
|
resetGroup OBJECT-GROUP
|
|
OBJECTS { systemReset
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The reset object group."
|
|
::= { ptpGroups 18 }
|
|
|
|
versionsGroup OBJECT-GROUP
|
|
OBJECTS { softwareVersion
|
|
, hardwareVersion
|
|
, secondarySoftwareVersion
|
|
, bootVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The versions object group."
|
|
::= { ptpGroups 19 }
|
|
|
|
pubStatsGroup OBJECT-GROUP
|
|
OBJECTS { receiveDataRate
|
|
, transmitDataRate
|
|
, aggregateDataRate
|
|
, wirelessLinkAvailability
|
|
, wirelessLinkStatus
|
|
, byteErrorRatio
|
|
, receiveModulationModeDetail
|
|
, dataBridgingAvailability
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The pubStats object group."
|
|
::= { ptpGroups 20 }
|
|
|
|
encryptionGroup OBJECT-GROUP
|
|
OBJECTS { encryptionAlgorithm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The encryption object group."
|
|
::= { ptpGroups 22 }
|
|
|
|
tDDControlGroup OBJECT-GROUP
|
|
OBJECTS { tDDSynchronizationMode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The tDDControl object group."
|
|
::= { ptpGroups 23 }
|
|
|
|
aAAControlGroup OBJECT-GROUP
|
|
OBJECTS { userTableNumber
|
|
, userName
|
|
, userRole
|
|
, userEnabled
|
|
, userPassword
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The aAAControl object group."
|
|
::= { ptpGroups 25 }
|
|
|
|
syslogControlGroup OBJECT-GROUP
|
|
OBJECTS { syslogClient
|
|
, syslogState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The syslogControl object group."
|
|
::= { ptpGroups 24 }
|
|
|
|
routerProtocolsGroup OBJECT-GROUP
|
|
OBJECTS { microwaveAdaptiveBandwidth
|
|
, mABNominalModulationMode
|
|
, mABTransmissionInterval
|
|
, mABHoldoffPeriod
|
|
, mABMaintenanceLevel
|
|
, useVLANForMABProtocol
|
|
, mABProtocolVID
|
|
, mABProtocolVLANPriority
|
|
, mABState
|
|
, mABNominalTransmitCapacity
|
|
, mABCurrentTransmitCapacity
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The routerProtocols object group."
|
|
::= { ptpGroups 26 }
|
|
|
|
cableDiagnosticsGroup OBJECT-GROUP
|
|
OBJECTS { cableDiagnosticsPorts
|
|
, cableDiagnosticsControl
|
|
, cableDiagnosticsWarning
|
|
, cableDiagnosticsResultTableNumber
|
|
, cableDiagnosticsResultsDateTime
|
|
, cableDiagPair1Results
|
|
, cableDiagPair1Distance
|
|
, cableDiagPair2Results
|
|
, cableDiagPair2Distance
|
|
, cableDiagPair3Results
|
|
, cableDiagPair3Distance
|
|
, cableDiagPair4Results
|
|
, cableDiagPair4Distance
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The cableDiagnostics object group."
|
|
::= { ptpGroups 27 }
|
|
|
|
supplementaryGroup OBJECT-GROUP
|
|
OBJECTS { longitude
|
|
, latitude
|
|
, altitude
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The supplementary object group."
|
|
::= { ptpGroups 96 }
|
|
|
|
notificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS { channelChangeTrap
|
|
, dfsImpulsiveInterferenceTrap
|
|
, mainPSUPortStatusTrap
|
|
, mainPSUPortDisabledWarningTrap
|
|
, mainPSUPortConfigurationMismatchTrap
|
|
, auxPortStatusTrap
|
|
, auxPortDisabledWarningTrap
|
|
, regulatoryBandTrap
|
|
, installStatusTrap
|
|
, installArmStateTrap
|
|
, unitOutOfCalibrationTrap
|
|
, auxPortPowerOverEthernetOutputStatusTrap
|
|
, incompatibleRegulatoryBandsTrap
|
|
, noWirelessChannelAvailableTrap
|
|
, wirelessLinkDisabledWarningTrap
|
|
, auxPortConfigurationMismatchTrap
|
|
, sFPErrorTrap
|
|
, sFPPortStatusTrap
|
|
, incompatibleMasterAndSlaveTrap
|
|
, sNTPSyncTrap
|
|
, tDDSynchronizationAlarmTrap
|
|
, sFPPortDisabledWarningTrap
|
|
, sFPPortConfigurationMismatchTrap
|
|
, linkModeOptimizationMismatchTrap
|
|
, tDMInterfaceStatusTrap
|
|
, tDMChannelStatusTrap
|
|
, tDMChannelLoopbackTrap
|
|
, nIDULanPortStatusTrap
|
|
, syslogStateTrap
|
|
, syslogLocalNearlyFullTrap
|
|
, syslogLocalWrappedTrap
|
|
, syslogClientTrap
|
|
, secureModeAlarmTrap
|
|
, dataBridgingStatusAlarmTrap
|
|
, licenseRemainingTrialPeriodAlarmTrap
|
|
, capacityVariantMismatchTrap
|
|
, maxLinkRangeExceededTrap
|
|
, tDMConfigurationMismatchTrap
|
|
, nIDULanPortDisabledWarningTrap
|
|
, nIDULanPortConfigurationMismatchTrap
|
|
, secondDataBridgingStatusAlarmTrap
|
|
, transparentClockSourcePortAlarmTrap
|
|
, portAllocationMismatchTrap
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "The notifications group."
|
|
::= { ptpGroups 99 }
|
|
|
|
|
|
DfsTableEntry ::=
|
|
SEQUENCE { dfsTableIndex INTEGER
|
|
, dfsMeans Integer32
|
|
, dfsNineNinePointNinePercentiles Integer32
|
|
, dfsPeaks Integer32
|
|
}
|
|
|
|
dfsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF DfsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A table storing a snapshot of various DFS measurements for each channel"
|
|
::= { dfs 2 }
|
|
|
|
dfsTableEntry OBJECT-TYPE
|
|
SYNTAX DfsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table DfsTable"
|
|
INDEX { dfsTableIndex }
|
|
::= { dfsTable 1 }
|
|
|
|
EthernetPriorityTableEntry ::=
|
|
SEQUENCE { ethernetPriorityTableIndex INTEGER
|
|
, ethernetPriorityQueueMapping INTEGER
|
|
}
|
|
|
|
ethernetPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EthernetPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A priority queue mapping table. This is a list of packet queues indexed by Ethernet priority."
|
|
::= { ethernet 15 }
|
|
|
|
ethernetPriorityTableEntry OBJECT-TYPE
|
|
SYNTAX EthernetPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table EthernetPriorityTable"
|
|
INDEX { ethernetPriorityTableIndex }
|
|
::= { ethernetPriorityTable 1 }
|
|
|
|
L2CPPriorityTableEntry ::=
|
|
SEQUENCE { l2CPPriorityTableIndex INTEGER
|
|
, l2CPPriorityQueueMapping INTEGER
|
|
}
|
|
|
|
l2CPPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF L2CPPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A priority queue mapping table. This is a list of packet queues indexed by L2CP priority."
|
|
::= { ethernet 17 }
|
|
|
|
l2CPPriorityTableEntry OBJECT-TYPE
|
|
SYNTAX L2CPPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table L2CPPriorityTable"
|
|
INDEX { l2CPPriorityTableIndex }
|
|
::= { l2CPPriorityTable 1 }
|
|
|
|
IPDSCPPriorityTableEntry ::=
|
|
SEQUENCE { iPDSCPPriorityTableIndex INTEGER
|
|
, iPDSCPPriorityQueueMapping INTEGER
|
|
}
|
|
|
|
iPDSCPPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IPDSCPPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A priority queue mapping table. This is a list of packet queues indexed by L3 IP DSCP priority."
|
|
::= { ethernet 19 }
|
|
|
|
iPDSCPPriorityTableEntry OBJECT-TYPE
|
|
SYNTAX IPDSCPPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table IPDSCPPriorityTable"
|
|
INDEX { iPDSCPPriorityTableIndex }
|
|
::= { iPDSCPPriorityTable 1 }
|
|
|
|
MPLSTCPriorityTableEntry ::=
|
|
SEQUENCE { mPLSTCPriorityTableIndex INTEGER
|
|
, mPLSTCPriorityQueueMapping INTEGER
|
|
}
|
|
|
|
mPLSTCPriorityTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MPLSTCPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A priority queue mapping table. This is a list of priority queues indexed by MPLS TC priority."
|
|
::= { ethernet 21 }
|
|
|
|
mPLSTCPriorityTableEntry OBJECT-TYPE
|
|
SYNTAX MPLSTCPriorityTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table MPLSTCPriorityTable"
|
|
INDEX { mPLSTCPriorityTableIndex }
|
|
::= { mPLSTCPriorityTable 1 }
|
|
|
|
TdmTableEntry ::=
|
|
SEQUENCE { tdmTableIndex INTEGER
|
|
, tDMChannelStatus INTEGER
|
|
, tDMChannelLineCode INTEGER
|
|
, tDMChannelCableLength INTEGER
|
|
, tDMChannelLoopback INTEGER
|
|
}
|
|
|
|
tdmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TdmTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" A table storing a configuration and status for each TDM channel"
|
|
::= { tDM 5 }
|
|
|
|
tdmTableEntry OBJECT-TYPE
|
|
SYNTAX TdmTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table TdmTable"
|
|
INDEX { tdmTableIndex }
|
|
::= { tdmTable 1 }
|
|
|
|
LicenseRegulatoryBandsTableEntry ::=
|
|
SEQUENCE { licenseRegulatoryBandsTableIndex INTEGER
|
|
, licenseRegulatoryBandsList INTEGER
|
|
}
|
|
|
|
licenseRegulatoryBandsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF LicenseRegulatoryBandsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { license 18 }
|
|
|
|
licenseRegulatoryBandsTableEntry OBJECT-TYPE
|
|
SYNTAX LicenseRegulatoryBandsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table LicenseRegulatoryBandsTable"
|
|
INDEX { licenseRegulatoryBandsTableIndex }
|
|
::= { licenseRegulatoryBandsTable 1 }
|
|
|
|
SNMPTrapTableEntry ::=
|
|
SEQUENCE { sNMPTrapTableIndex INTEGER
|
|
, sNMPTrapPortNumber INTEGER
|
|
, sNMPTrapInternetAddressType INTEGER
|
|
, sNMPTrapInternetAddress InetAddress
|
|
, sNMPTrapReceiverEnabled INTEGER
|
|
}
|
|
|
|
sNMPTrapTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SNMPTrapTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" SNMP trap configuration table."
|
|
::= { snmpControl 4 }
|
|
|
|
sNMPTrapTableEntry OBJECT-TYPE
|
|
SYNTAX SNMPTrapTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table SNMPTrapTable"
|
|
INDEX { sNMPTrapTableIndex }
|
|
::= { sNMPTrapTable 1 }
|
|
|
|
SNTPServerTableEntry ::=
|
|
SEQUENCE { sNTPServerTableIndex INTEGER
|
|
, sNTPServerPortNumber INTEGER
|
|
, sNTPServerStatus DisplayString
|
|
, sNTPServerInternetAddressType INTEGER
|
|
, sNTPServerInternetAddress InetAddress
|
|
}
|
|
|
|
sNTPServerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SNTPServerTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { sntp 15 }
|
|
|
|
sNTPServerTableEntry OBJECT-TYPE
|
|
SYNTAX SNTPServerTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table SNTPServerTable"
|
|
INDEX { sNTPServerTableIndex }
|
|
::= { sNTPServerTable 1 }
|
|
|
|
UserTableEntry ::=
|
|
SEQUENCE { userTableIndex INTEGER
|
|
, userName DisplayString
|
|
, userRole INTEGER
|
|
, userEnabled INTEGER
|
|
, userPassword DisplayString
|
|
}
|
|
|
|
userTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UserTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The User Table Control group contains objects specifically for user account management."
|
|
::= { aAAControl 2 }
|
|
|
|
userTableEntry OBJECT-TYPE
|
|
SYNTAX UserTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table UserTable"
|
|
INDEX { userTableIndex }
|
|
::= { userTable 1 }
|
|
|
|
CableDiagnosticsResultTableEntry ::=
|
|
SEQUENCE { cableDiagnosticsResultTableIndex INTEGER
|
|
, cableDiagnosticsResultsDateTime Integer32
|
|
, cableDiagPair1Results INTEGER
|
|
, cableDiagPair1Distance Integer32
|
|
, cableDiagPair2Results INTEGER
|
|
, cableDiagPair2Distance Integer32
|
|
, cableDiagPair3Results INTEGER
|
|
, cableDiagPair3Distance Integer32
|
|
, cableDiagPair4Results INTEGER
|
|
, cableDiagPair4Distance Integer32
|
|
}
|
|
|
|
cableDiagnosticsResultTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CableDiagnosticsResultTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { cableDiagnostics 5 }
|
|
|
|
cableDiagnosticsResultTableEntry OBJECT-TYPE
|
|
SYNTAX CableDiagnosticsResultTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Table CableDiagnosticsResultTable"
|
|
INDEX { cableDiagnosticsResultTableIndex }
|
|
::= { cableDiagnosticsResultTable 1 }
|
|
|
|
-- Dfs group attribute definitions
|
|
--
|
|
dfsTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the dfsTable"
|
|
::= { dfs 1 }
|
|
|
|
extendedSpectrumScanning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables Extended Spectrum Scanning"
|
|
::= { dfs 3 }
|
|
|
|
-- DfsTable group attribute definitions
|
|
--
|
|
dfsTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"used to index values in the dfsTable."
|
|
::= { dfsTableEntry 1 }
|
|
|
|
dfsMeans OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Snapshot of DFS means"
|
|
::= { dfsTableEntry 2 }
|
|
|
|
dfsNineNinePointNinePercentiles OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Snapshot of DFS 99.9 percentiles"
|
|
::= { dfsTableEntry 3 }
|
|
|
|
dfsPeaks OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Snapshot of DFS peaks"
|
|
::= { dfsTableEntry 4 }
|
|
|
|
-- Bridge group attribute definitions
|
|
--
|
|
localPacketFiltering OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Local Packet Filtering is Enabled, the unit keeps
|
|
track of the port (Main, SFP, Aux or Wireless) on which a
|
|
packet with a given MAC source address destined to the
|
|
management agent has been received. This MAC address to
|
|
port mapping is then used in order to route any response
|
|
from the management agent to the right port. When Local
|
|
Packet Filtering is Disabled, any Ethernet packet from
|
|
the management agent is sent to all ports."
|
|
::= { bridge 1 }
|
|
|
|
-- Configuration group attribute definitions
|
|
--
|
|
iPv4Address OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internet protocol (IPv4) address. This address is used
|
|
by the family of Internet protocols to uniquely identify
|
|
the unit on a network."
|
|
::= { configuration 1 }
|
|
|
|
subnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A subnet allows the flow of network traffic between
|
|
hosts to be segregated based on a network configuration.
|
|
By organizing hosts into logical groups, subnetting can
|
|
improve network security and performance."
|
|
::= { configuration 2 }
|
|
|
|
gatewayIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv4 address of a device on the current network that
|
|
acts as an IPv4 network gateway. A gateway acts as an
|
|
entrance / exit to packets from / to other networks"
|
|
::= { configuration 3 }
|
|
|
|
targetMACAddress OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(6))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of the PTP wireless unit forming the other
|
|
end of the PTP link"
|
|
::= { configuration 4 }
|
|
|
|
masterSlaveMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The PTP wireless link operates using a master and slave
|
|
relationship"
|
|
::= { configuration 5 }
|
|
|
|
maximumTransmitPower OBJECT-TYPE
|
|
SYNTAX INTEGER (-15..30)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum transmit power the wireless unit is permitted to
|
|
use when establishing and maintaining the wireless link.
|
|
This may be reduced during installation"
|
|
::= { configuration 6 }
|
|
|
|
antennaGain OBJECT-TYPE
|
|
SYNTAX INTEGER (130..610)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Antenna Gain. Expressed in 10ths of dBi."
|
|
::= { configuration 7 }
|
|
|
|
cableLoss OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Loss in the cable between the ODU and the antenna.
|
|
Expressed in 10ths of dB. NB: This attribute is ignored
|
|
for variants with an integral antenna."
|
|
::= { configuration 8 }
|
|
|
|
eIRP OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Effective Isotropic Radiated Power (EIRP) describes the
|
|
strength of the radio signal leaving the wireless unit.
|
|
Expressed in 10ths of dBm"
|
|
::= { configuration 9 }
|
|
|
|
channelBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bw30MHz(0),
|
|
bw15MHz(1),
|
|
bw10MHz(2),
|
|
bw5MHz(3),
|
|
bw20MHz(4),
|
|
bw56MHz(5),
|
|
bw50MHz(6),
|
|
bw40MHz(7),
|
|
bw45MHz(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This control sets the bandwidth of the transmit and
|
|
receive radio channels"
|
|
::= { configuration 11 }
|
|
|
|
linkName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the PTP link allocated by the System
|
|
Administrator. Used to establish a connection with the
|
|
correct PTP wireless unit at the other end of the link.
|
|
NOTE: The link name MUST be the same at both ends of the
|
|
PTP link."
|
|
::= { configuration 14 }
|
|
|
|
siteName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This field contains a user-provided description of the
|
|
site name together with any additional notes"
|
|
::= { configuration 15 }
|
|
|
|
accessMethod OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
linkAccess(0),
|
|
linkNameAccess(1),
|
|
groupAccess(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ODUs must be configured in pairs before a link can be
|
|
established. The Access Method attribute determines how
|
|
the paired ODUs will recognise each other. For the Link
|
|
Access method, each ODU must be configured with Target
|
|
MAC Address equal to the MAC Address of the other unit.
|
|
For the Link Name Access method, both units must be
|
|
configured with the same Link Name. For the Group Access
|
|
method, both units must be configured with the same Group
|
|
ID."
|
|
::= { configuration 16 }
|
|
|
|
groupID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When Access Method is set to Group Access, the Group ID
|
|
identifies all the units belonging to the same group"
|
|
::= { configuration 17 }
|
|
|
|
iPv6Address OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..39))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internet protocol (IPv6) address. This address is used
|
|
by the family of Internet protocols to uniquely identify
|
|
the unit on a network."
|
|
::= { configuration 18 }
|
|
|
|
iPVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
iPv4(0),
|
|
iPv6(1),
|
|
dualIPv4andIPv6(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP protocol selection. Choice of IPv4, IPv6 or Dual."
|
|
::= { configuration 20 }
|
|
|
|
iPv6AutoConfiguredLinkLocalAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..39))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auto configured link local IPv6 address"
|
|
::= { configuration 21 }
|
|
|
|
iPv6PrefixLength OBJECT-TYPE
|
|
SYNTAX INTEGER (0..128)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 prefix length"
|
|
::= { configuration 22 }
|
|
|
|
iPv6GatewayAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..39))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPv6 address of a device on the current network that
|
|
is currently acting as an IPv6 network gateway. A gateway
|
|
acts as an entrance / exit to packets from / to other
|
|
networks."
|
|
::= { configuration 23 }
|
|
|
|
remoteInternetAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ipv4(1),
|
|
ipv6(2),
|
|
ipv4z(3),
|
|
ipv6z(4),
|
|
unknown6(5),
|
|
unknown7(6),
|
|
unknown8(7),
|
|
unknown9(8),
|
|
unknown10(9),
|
|
unknown11(10),
|
|
unknown12(11),
|
|
unknown13(12),
|
|
unknown14(13),
|
|
unknown15(14),
|
|
unknown16(15),
|
|
dns(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Internet address specified by the associated
|
|
remoteInternetAddressType."
|
|
::= { configuration 24 }
|
|
|
|
remoteInternetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"INET address used to identify the peer wireless unit"
|
|
::= { configuration 25 }
|
|
|
|
subbandLowestFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Lowest center frequency of the subset of channels."
|
|
::= { configuration 26 }
|
|
|
|
subbandHighestFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Highest center frequency of the subset of channels."
|
|
::= { configuration 27 }
|
|
|
|
enableTransmission OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(0),
|
|
muted(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control for enabling/disabling the radio transmitter of
|
|
the Master. Note: Use Web Properties to control this
|
|
feature."
|
|
::= { configuration 28 }
|
|
|
|
-- Ethernet group attribute definitions
|
|
--
|
|
mainPSUPortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether the local Ethernet interface
|
|
configuration is automatically negotiated or forced. Do
|
|
not use a forced setting together with auto negotiation
|
|
at the Ethernet link partner. If you want to run your
|
|
Ethernet link at a fixed speed and duplex then you would
|
|
normally leave auto negotiation enabled and only enable
|
|
the single Auto Neg Advertisement option that you want
|
|
the link to run in - FORCING ETHERNET CONFIGURATION IS A
|
|
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
|
|
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
|
|
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
|
|
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
|
|
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
|
|
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
|
|
new setting will only take effect after a system reboot."
|
|
::= { ethernet 1 }
|
|
|
|
mainPSUPortAutoNegAdvertisement OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
negInvalid(2),
|
|
neg10MbpsHalfDuplex(3),
|
|
neg10MbpsFullDuplex(4),
|
|
neg100MbpsHalfDuplex(5),
|
|
neg100MbpsFullDuplex(6),
|
|
neg1000MbpsFullDuplex(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the different Ethernet configurations that
|
|
will be advertised during auto negotiation. Note the new
|
|
setting will only take effect after a system reboot.
|
|
WARNING: Duplex mismatch may result if both ends of the
|
|
Ethernet link do not have the same settings. Do not auto
|
|
negotiation together with a fixed setting at the Ethernet
|
|
link partner. WARNING: Make sure that you select
|
|
option(s) that you know your connected equipment can
|
|
cater for!"
|
|
::= { ethernet 2 }
|
|
|
|
mainPSUPortAutoMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This enables/disables the Auto MDI/MDIX capability. NB:
|
|
The new setting will only take effect after a system
|
|
reboot"
|
|
::= { ethernet 3 }
|
|
|
|
mainPSUPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
copperLinkUp(1),
|
|
fiberLinkUp(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Main PSU Ethernet link. NB: a
|
|
change of state may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { ethernet 4 }
|
|
|
|
mainPSUPortSpeedAndDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
speed1000MbpsFullDuplex(0),
|
|
speed100MbpsFullDuplex(1),
|
|
speed100MbpsHalfDuplex(2),
|
|
speed10MbpsFullDuplex(3),
|
|
speed10MbpsHalfDuplex(4),
|
|
speedUnknown6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current speed and duplex of the Main PSU Ethernet
|
|
link"
|
|
::= { ethernet 5 }
|
|
|
|
dataPortWirelessDownAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled, this causes the Ethernet link to be
|
|
dropped briefly when the wireless link drops. This is so
|
|
that spanning tree algorithms can quickly detect that
|
|
there is a problem."
|
|
::= { ethernet 6 }
|
|
|
|
useVLANForManagementInterfaces OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noVLANTagging(0),
|
|
iEEE8021QTaggedCTagType8100(1),
|
|
iEEE8021adTaggedSTagorBTagType88a8(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether the management interfaces
|
|
(WWW/SNMP/SMTP/SNTP) use VLAN tags or not. NB: The new
|
|
setting will only take effect after a system reboot"
|
|
::= { ethernet 7 }
|
|
|
|
vLANManagementPriority OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
p0(0),
|
|
p1(1),
|
|
p2(2),
|
|
p3(3),
|
|
p4(4),
|
|
p5(5),
|
|
p6(6),
|
|
p7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This VLAN Priority (0-7) will be included in packets
|
|
generated by the management interfaces"
|
|
::= { ethernet 8 }
|
|
|
|
vLANManagementVID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This VLAN VID (0-4094) will be included in packets
|
|
generated by the management interfaces. Note the new
|
|
setting will only take effect after a system reboot"
|
|
::= { ethernet 11 }
|
|
|
|
auxPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
copperLinkUp(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Aux Ethernet link. NB: a change of
|
|
state may generate an SNMP trap and/or SMTP email alert"
|
|
::= { ethernet 12 }
|
|
|
|
auxPortSpeedAndDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
speed1000MbpsFullDuplex(0),
|
|
speed100MbpsFullDuplex(1),
|
|
speed100MbpsHalfDuplex(2),
|
|
speed10MbpsFullDuplex(3),
|
|
speed10MbpsHalfDuplex(4),
|
|
speedUnknown6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current speed and duplex of the Aux Ethernet link"
|
|
::= { ethernet 13 }
|
|
|
|
ethernetPriorityTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (9)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the vLANPriorityTable."
|
|
::= { ethernet 14 }
|
|
|
|
l2CPPriorityTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the l2CPPriorityTable."
|
|
::= { ethernet 16 }
|
|
|
|
iPDSCPPriorityTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (64)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the iPDSCPPriorityTable."
|
|
::= { ethernet 18 }
|
|
|
|
mPLSTCPriorityTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the mPLSTCPriorityTable."
|
|
::= { ethernet 20 }
|
|
|
|
managementPortWirelessDownAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled, this causes the management link to be
|
|
dropped briefly when the wireless link drops. This is so
|
|
that spanning tree algorithms can quickly detect that
|
|
there is a problem."
|
|
::= { ethernet 23 }
|
|
|
|
qOSPriorityScheme OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ethernet(0),
|
|
iPMPLS(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selects classification based on fields in the Ethernet
|
|
header (Layer 2) or in the Network header (Layer 3). The
|
|
unit recognises two network layer protocols: IP and MPLS"
|
|
::= { ethernet 24 }
|
|
|
|
unknownNetworkPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of unknown network
|
|
protocols to an egress queue at the wireless port.
|
|
Unknown means something other than IP and MPLS"
|
|
::= { ethernet 25 }
|
|
|
|
dSCPManagementPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Differentiated Services Code Point value will be
|
|
inserted in the IP Header of all IP Datagrams transmitted
|
|
by the management interfaces"
|
|
::= { ethernet 26 }
|
|
|
|
dataBridgingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of Ethernet Data traffic bridging over
|
|
the wireless link"
|
|
::= { ethernet 27 }
|
|
|
|
mainPSUPortAllocation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
dataOnly(1),
|
|
dataandInBandManagement(2),
|
|
outofBandLocalManagement(3),
|
|
outofBandRemoteManagement(4),
|
|
secondDataOnly(5),
|
|
secondDataandInBandManagement(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the service or services supported by the Main
|
|
PSU Ethernet port"
|
|
::= { ethernet 28 }
|
|
|
|
auxPortAllocation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
dataOnly(1),
|
|
dataandInBandManagement(2),
|
|
outofBandLocalManagement(3),
|
|
outofBandRemoteManagement(4),
|
|
secondDataOnly(5),
|
|
secondDataandInBandManagement(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the service or services supported by the Aux
|
|
Ethernet port"
|
|
::= { ethernet 29 }
|
|
|
|
sFPPortAllocation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
dataOnly(1),
|
|
dataandInBandManagement(2),
|
|
outofBandLocalManagement(3),
|
|
outofBandRemoteManagement(4),
|
|
secondDataOnly(5),
|
|
secondDataandInBandManagement(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the service or services supported by the SFP
|
|
Ethernet port"
|
|
::= { ethernet 30 }
|
|
|
|
dataPortPauseFrames OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tunnel(0),
|
|
discard(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the bridge tunnels or discards Layer 2
|
|
PAUSE frames arriving at the Data Port. Such frames are
|
|
identified by the destination MAC Address being equal to
|
|
01-80-C2-00-00-01"
|
|
::= { ethernet 31 }
|
|
|
|
sFPPortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether the local SFP Ethernet interface
|
|
configuration is automatically negotiated or forced. Do
|
|
not use a forced setting together with auto negotiation
|
|
at the Ethernet link partner. If you want to run your
|
|
Ethernet link at a fixed speed and duplex then you would
|
|
normally leave auto negotiation enabled and only enable
|
|
the single Auto Neg Advertisement option that you want
|
|
the link to run in - FORCING ETHERNET CONFIGURATION IS A
|
|
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
|
|
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
|
|
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
|
|
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
|
|
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
|
|
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
|
|
new setting will only take effect after a system reboot."
|
|
::= { ethernet 32 }
|
|
|
|
sFPPortAutoNegAdvertisement OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
negInvalid(2),
|
|
neg10MbpsHalfDuplex(3),
|
|
neg10MbpsFullDuplex(4),
|
|
neg100MbpsHalfDuplex(5),
|
|
neg100MbpsFullDuplex(6),
|
|
neg1000MbpsFullDuplex(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the different SFP Ethernet configurations that
|
|
will be advertised during auto negotiation. Note the new
|
|
setting will only take effect after a system reboot.
|
|
WARNING: Duplex mismatch may result if both ends of the
|
|
Ethernet link do not have the same settings. Do not auto
|
|
negotiation together with a fixed setting at the Ethernet
|
|
link partner. WARNING: Make sure that you select
|
|
option(s) that you know your connected equipment can
|
|
cater for!"
|
|
::= { ethernet 33 }
|
|
|
|
sFPPortAutoMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This enables/disables the Auto MDI/MDIX capability. NB:
|
|
The new setting will only take effect after a system
|
|
reboot"
|
|
::= { ethernet 34 }
|
|
|
|
sFPPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
copperLinkUp(1),
|
|
fiberLinkUp(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the SFP Ethernet link. NB: a change of
|
|
state may generate an SNMP trap and/or SMTP email alert"
|
|
::= { ethernet 35 }
|
|
|
|
sFPPortSpeedAndDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
speed1000MbpsFullDuplex(0),
|
|
speed100MbpsFullDuplex(1),
|
|
speed100MbpsHalfDuplex(2),
|
|
speed10MbpsFullDuplex(3),
|
|
speed10MbpsHalfDuplex(4),
|
|
speedUnknown6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current speed and duplex of the SFP Ethernet link"
|
|
::= { ethernet 36 }
|
|
|
|
auxPortPowerOverEthernetOutput OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The state of the Power Over Ethernet (PoE) output of the
|
|
Aux port. Enabling PoE output may lead to system
|
|
instability; please refer to the User Guide before
|
|
enabling this control"
|
|
::= { ethernet 37 }
|
|
|
|
auxPortPowerOverEthernetOutputStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
poEOutputOn(0),
|
|
poEOutputDisabled(1),
|
|
poEOutputEnabledbutNotActiveErrororNoLoadPresent(2),
|
|
poEOutputOverloadError(3),
|
|
poEOutputOverTempError(4),
|
|
poEOutputErrorDetected(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Power Over Ethernet (PoE) output
|
|
of the Aux port"
|
|
::= { ethernet 38 }
|
|
|
|
syncETracking OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
internalTDMUseOnly(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether Synchronous Ethernet (SyncE) network
|
|
synchronization is enabled."
|
|
::= { ethernet 39 }
|
|
|
|
syncEEquipmentClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eECOption1(0),
|
|
eECOption2(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"EEC-Option 1 applies to synchronous Ethernet equipments
|
|
that are designed to interwork with networks optimized
|
|
for the 2048-kbit/s hierarchy. Corresponds to ITU-T G.813
|
|
Option 1; EEC-Option 2 applies to synchronous Ethernet
|
|
equipments that are designed to interwork with networks
|
|
optimized for the 1544-kbit/s hierarchy. Corresponds to
|
|
Type IV clock from ITU-T G.812."
|
|
::= { ethernet 40 }
|
|
|
|
mainPSUPortQLRxOverwrite OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Override for the Synchronous Ethernet (SyncE) received
|
|
Quality Level (QL) on the main PSU port."
|
|
::= { ethernet 41 }
|
|
|
|
mainPSUPortSSMTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the Synchronous Ethernet (SyncE)
|
|
Quality Level (QL) is transmitted on the Main PSU port"
|
|
::= { ethernet 42 }
|
|
|
|
sFPPortSSMTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the Synchronous Ethernet (SyncE)
|
|
Quality Level (QL) is transmitted on the SFP port"
|
|
::= { ethernet 43 }
|
|
|
|
auxPortSSMTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the Synchronous Ethernet (SyncE)
|
|
Quality Level (QL) is transmitted on the Aux port"
|
|
::= { ethernet 44 }
|
|
|
|
syncETrackingState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
acquiringWirelessLock(1),
|
|
freeRunning(2),
|
|
lockedLocalAcquiringHoldover(3),
|
|
lockedLocalHoldoverAcquired(4),
|
|
holdover(5),
|
|
lockedRemoteAcquiringHoldover(6),
|
|
lockedRemoteHoldoverAcquired(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current state of Synchronous Ethernet (SyncE)
|
|
network synchronization."
|
|
::= { ethernet 45 }
|
|
|
|
mainPSUPortQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently being received on the main PSU port."
|
|
::= { ethernet 46 }
|
|
|
|
auxPortQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently being received on the auxiliary port."
|
|
::= { ethernet 47 }
|
|
|
|
sFPPortQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently being received on the SFP port."
|
|
::= { ethernet 48 }
|
|
|
|
mainPSUPortQLTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) transmit Quality Level
|
|
(QL) of the main PSU port."
|
|
::= { ethernet 49 }
|
|
|
|
auxPortQLTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) transmit Quality Level
|
|
(QL) of the auxiliary port."
|
|
::= { ethernet 50 }
|
|
|
|
sFPPortQLTx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) transmit Quality Level
|
|
(QL) of the SFP port."
|
|
::= { ethernet 51 }
|
|
|
|
mainPSUPortSyncEMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main PSU port Synchronous Ethernet (SyncE)
|
|
Master/Slave status"
|
|
::= { ethernet 52 }
|
|
|
|
auxPortSyncEMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auxiliary port Synchronous Ethernet (SyncE)
|
|
Master/Slave status"
|
|
::= { ethernet 53 }
|
|
|
|
sFPPortSyncEMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SFP port Synchronous Ethernet (SyncE) Master/Slave
|
|
status"
|
|
::= { ethernet 54 }
|
|
|
|
mainPSUPortGigabitMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1),
|
|
notApplicable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main PSU port Gigabit Ethernet Master/Slave status"
|
|
::= { ethernet 55 }
|
|
|
|
auxPortGigabitMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1),
|
|
notApplicable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The auxiliary port Gigabit Ethernet Master/Slave status"
|
|
::= { ethernet 56 }
|
|
|
|
sFPPortGigabitMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1),
|
|
notApplicable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SFP port Gigabit Ethernet Master/Slave status"
|
|
::= { ethernet 57 }
|
|
|
|
transparentClock OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This control enables the Precision Time Protocol
|
|
(IEEE-1588) Transparent Clock. Once enabled the unit will
|
|
modify the correction field in PTP event messages to take
|
|
account of the time these frames have been resident in
|
|
this system. This will happen for all PTP frames at Layer
|
|
2 & Layer 3 (IPv4 & IPv6) unless a transparent clock VLAN
|
|
is enabled."
|
|
::= { ethernet 58 }
|
|
|
|
transparentClockVLAN OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
all(0),
|
|
sTagged(1),
|
|
cTagged(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If All is selected then all PTP frames will have their
|
|
correction fields modified with the residence time. If an
|
|
S-TAG or C-TAG is selected, only frames with this VLAN
|
|
tag and matching the VLAN ID in the Transparent Clock VID
|
|
will have their correction fields modified."
|
|
::= { ethernet 59 }
|
|
|
|
transparentClockVID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4094)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VLAN ID which frames must match if they are to be
|
|
corrected. Only valid when an S-TAG or C-TAG has been
|
|
selected."
|
|
::= { ethernet 60 }
|
|
|
|
mainPSUPortAcceptedQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently accepted (validated) on the main PSU port."
|
|
::= { ethernet 61 }
|
|
|
|
auxPortAcceptedQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently accepted (validated) on the auxiliary port."
|
|
::= { ethernet 62 }
|
|
|
|
sFPPortAcceptedQLRx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
qLPRS(1),
|
|
qLSTU(2),
|
|
qLPRC(3),
|
|
qLST2(4),
|
|
qLSSUAQLTNC(5),
|
|
qLSSUB(6),
|
|
qLST3E(7),
|
|
qLEEC2QLST3(8),
|
|
qLEEC1QLSEC(9),
|
|
qLSMC(10),
|
|
qLPROV(11),
|
|
qLDNUQLDUS(12),
|
|
qLFAILED(13)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Quality Level (QL)
|
|
currently accepted (validated) on the SFP port."
|
|
::= { ethernet 63 }
|
|
|
|
mainPSUPortSyncERxStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
good(0),
|
|
waittoRestore(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Receive Status of the
|
|
main PSU port"
|
|
::= { ethernet 64 }
|
|
|
|
auxPortSyncERxStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
good(0),
|
|
waittoRestore(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Receive Status of the
|
|
auxiliary port"
|
|
::= { ethernet 65 }
|
|
|
|
sFPPortSyncERxStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
good(0),
|
|
waittoRestore(1),
|
|
failed(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Synchronous Ethernet (SyncE) Receive Status of the
|
|
SFP port"
|
|
::= { ethernet 66 }
|
|
|
|
nIDULanPortStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
down(0),
|
|
copperLinkUp(1),
|
|
fiberLinkUp(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the NIDU LAN Ethernet link. NB: a
|
|
change of state may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { ethernet 67 }
|
|
|
|
nIDULanPortSpeedAndDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
speed1000MbpsFullDuplex(0),
|
|
speed100MbpsFullDuplex(1),
|
|
speed100MbpsHalfDuplex(2),
|
|
speed10MbpsFullDuplex(3),
|
|
speed10MbpsHalfDuplex(4),
|
|
speedUnknown6(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current speed and duplex of the Ethernet link to the
|
|
NIDU LAN Port"
|
|
::= { ethernet 68 }
|
|
|
|
oOBPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of traffic to an egress
|
|
queue at the wireless port"
|
|
::= { ethernet 69 }
|
|
|
|
nIDULanPortAutoNegotiation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether the local Ethernet interface
|
|
configuration is automatically negotiated or forced. Do
|
|
not use a forced setting together with auto negotiation
|
|
at the Ethernet link partner. If you want to run your
|
|
Ethernet link at a fixed speed and duplex then you would
|
|
normally leave auto negotiation enabled and only enable
|
|
the single Auto Neg Advertisement option that you want
|
|
the link to run in - FORCING ETHERNET CONFIGURATION IS A
|
|
LAST RESORT WHICH SHOULD ONLY BE PERFORMED IF YOU ARE
|
|
HAVING PROBLEMS WITH AUTO NEGOTIATION - AND YOU MUST
|
|
ENSURE THAT YOU CONFIGURE BOTH THIS UNIT AND THE ETHERNET
|
|
LINK PARTNER TO WHICH IT IS CONNECTED IDENTICALLY (THE
|
|
LINK PARTNER MUST NOT HAVE AUTO NEGOTIATION ENABLED
|
|
EITHER, OTHERWISE A DUPLEX MISMATCH WILL OCCUR). NB: The
|
|
new setting will only take effect after a system reboot."
|
|
::= { ethernet 70 }
|
|
|
|
nIDULanPortAutoNegAdvertisement OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
negInvalid(2),
|
|
neg10MbpsHalfDuplex(3),
|
|
neg10MbpsFullDuplex(4),
|
|
neg100MbpsHalfDuplex(5),
|
|
neg100MbpsFullDuplex(6),
|
|
neg1000MbpsFullDuplex(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sets the different Ethernet configurations that
|
|
will be advertised during auto negotiation. Note the new
|
|
setting will only take effect after a system reboot.
|
|
WARNING: Duplex mismatch may result if both ends of the
|
|
Ethernet link do not have the same settings. Do not auto
|
|
negotiation together with a fixed setting at the Ethernet
|
|
link partner. WARNING: Make sure that you select
|
|
option(s) that you know your connected equipment can
|
|
cater for!"
|
|
::= { ethernet 71 }
|
|
|
|
nIDULanPortAutoMdix OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This enables/disables the Auto MDI/MDIX capability. NB:
|
|
The new setting will only take effect after a system
|
|
reboot"
|
|
::= { ethernet 72 }
|
|
|
|
nIDULanPortGigabitMasterSlaveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
master(0),
|
|
slave(1),
|
|
notApplicable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIDU LAN port Gigabit Ethernet Master/Slave status"
|
|
::= { ethernet 73 }
|
|
|
|
txMABFrames OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of MAB frames transmitted"
|
|
::= { ethernet 74 }
|
|
|
|
managementNetworkAccessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled the local Out-of-Band interface can be used
|
|
to access the remote management network. If not enabled
|
|
the local management agent can still be accessed from the
|
|
remote management network and the local Out-of-Band
|
|
interface"
|
|
::= { ethernet 75 }
|
|
|
|
secondDataPortPauseFrames OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tunnel(0),
|
|
discard(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether the bridge tunnels or discards Layer 2
|
|
PAUSE frames arriving at the Second Data Service Port.
|
|
Such frames are identified by the destination MAC Address
|
|
being equal to 01-80-C2-00-00-01"
|
|
::= { ethernet 76 }
|
|
|
|
secondDataBridgingStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of bridging Second Data Service Ethernet
|
|
traffic over the wireless link"
|
|
::= { ethernet 80 }
|
|
|
|
transparentClockPort OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mainPSU(0),
|
|
aux(1),
|
|
sFP(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IEEE 1588 Transparent Clock source"
|
|
::= { ethernet 81 }
|
|
|
|
-- EthernetPriorityTable group attribute definitions
|
|
--
|
|
ethernetPriorityTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
p0(1),
|
|
p1(2),
|
|
p2(3),
|
|
p3(4),
|
|
p4(5),
|
|
p5(6),
|
|
p6(7),
|
|
p7(8),
|
|
untagged(9)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet priority flag, used to index values in the
|
|
ethernetPriorityTable"
|
|
::= { ethernetPriorityTableEntry 1 }
|
|
|
|
ethernetPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of this Ethernet priority
|
|
(also known as IEEE 802.1p value) to an egress queue at
|
|
the wireless port"
|
|
::= { ethernetPriorityTableEntry 2 }
|
|
|
|
-- L2CPPriorityTable group attribute definitions
|
|
--
|
|
l2CPPriorityTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bridge(1),
|
|
mRP(2),
|
|
cFM(3),
|
|
rAPS(4),
|
|
eAPS(5)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"L2CP priority flag, used to index values in the
|
|
l2CPPriorityTable"
|
|
::= { l2CPPriorityTableEntry 1 }
|
|
|
|
l2CPPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of this layer two control
|
|
protocol (L2CP) to an egress queue at the wireless port"
|
|
::= { l2CPPriorityTableEntry 2 }
|
|
|
|
-- IPDSCPPriorityTable group attribute definitions
|
|
--
|
|
iPDSCPPriorityTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..64)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP DSCP priority flag, used to index values in the
|
|
iPDSCPPriorityTable"
|
|
::= { iPDSCPPriorityTableEntry 1 }
|
|
|
|
iPDSCPPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of this IP differentiated
|
|
services code point (DSCP) value to an egress queue at
|
|
the wireless port"
|
|
::= { iPDSCPPriorityTableEntry 2 }
|
|
|
|
-- MPLSTCPriorityTable group attribute definitions
|
|
--
|
|
mPLSTCPriorityTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MPLS TC priority flag, used to index values in the
|
|
mPLSTCPriorityTable"
|
|
::= { mPLSTCPriorityTableEntry 1 }
|
|
|
|
mPLSTCPriorityQueueMapping OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
q0(0),
|
|
q1(1),
|
|
q2(2),
|
|
q3(3),
|
|
q4(4),
|
|
q5(5),
|
|
q6(6),
|
|
q7(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configures the classification of this MPLS traffic class
|
|
(the field formerly known as EXP) to an egress queue at
|
|
the wireless port"
|
|
::= { mPLSTCPriorityTableEntry 2 }
|
|
|
|
-- TDM group attribute definitions
|
|
--
|
|
tDMInterfaceControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
e1(1),
|
|
t1(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line interface type. If this is set to 'None' then
|
|
the TDM interfaces are disabled, and the TDM settings
|
|
will be ignored."
|
|
::= { tDM 1 }
|
|
|
|
tDMInterfaceStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
connectedNotConfigured(1),
|
|
notConnected(2),
|
|
nIDUdetectedonAUXport(3),
|
|
error(4),
|
|
codeDownloadInProgress(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"@Current status of the connection to the TDM Box. A
|
|
state of 'Up' on a green background indicates that the
|
|
TDM Box is connected OK. When connecting a TDM Box only
|
|
the Main Ethernet port should be used"
|
|
::= { tDM 2 }
|
|
|
|
tDMEnabledChannels OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of TDM channels enabled in the system"
|
|
::= { tDM 3 }
|
|
|
|
tdmTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the TdmTable"
|
|
::= { tDM 4 }
|
|
|
|
tDMConfigurationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
linetypemismatch(1),
|
|
enabledchannelsmismatch(2),
|
|
linetypeandenabledchannelsmismatch(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the configuration of the TDM Box. A
|
|
state of 'Ok' on a green background indicates that the
|
|
TDM Box configuration is matched OK with the remote end."
|
|
::= { tDM 6 }
|
|
|
|
lowestTDMModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest modulation mode at which tdm data will be
|
|
sent. The effective lowest modulation mode is displayed
|
|
in the TDM Configuration page"
|
|
::= { tDM 7 }
|
|
|
|
-- TdmTable group attribute definitions
|
|
--
|
|
tdmTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TDM Channel flag, used to index channels in the
|
|
TdmTable"
|
|
::= { tdmTableEntry 1 }
|
|
|
|
tDMChannelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(0),
|
|
noSignalLocal(1),
|
|
noSignalRemote(2),
|
|
noSignalLocalandRemote(3),
|
|
remoteTiming(4),
|
|
noSignalLocalandRemoteTiming(5),
|
|
disabled(6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the TDM channels. A value of 0
|
|
indicates that a TDM channel is established"
|
|
::= { tdmTableEntry 2 }
|
|
|
|
tDMChannelLineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
aMI(0),
|
|
b8ZSorHDB3(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line code setting of the TDM interfaces. This must
|
|
match the setting of the device connected to an
|
|
interface"
|
|
::= { tdmTableEntry 3 }
|
|
|
|
tDMChannelCableLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
feet133(0),
|
|
feet266(1),
|
|
feet399(2),
|
|
feet533(3),
|
|
feet655(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lengths of the cables connected to the TDM
|
|
interfaces, measured in feet"
|
|
::= { tdmTableEntry 4 }
|
|
|
|
tDMChannelLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
copper(1),
|
|
wireless(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The loopback status of TDM channels. This is intended
|
|
for installation testing and should be set to 'None' for
|
|
normal operation. The wire connections to a unit can be
|
|
tested by applying a 'Copper' loopback to the local unit.
|
|
The wireless connection to the remote unit can be tested
|
|
by applying a 'Wireless' loopback to the remote unit with
|
|
no loopback on the local unit. NB: a change of state may
|
|
generate an SNMP trap and/or SMTP email alert"
|
|
::= { tdmTableEntry 5 }
|
|
|
|
-- License group attribute definitions
|
|
--
|
|
regulatoryBand OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
regInvalid(0),
|
|
reg158GHz(1),
|
|
reg258GHz(2),
|
|
reg358GHz(3),
|
|
reg458GHz(4),
|
|
reg558GHz(5),
|
|
reg658GHz(6),
|
|
reg754GHzUnrestrictedEIRPwithDFS(7),
|
|
reg854GHzUnrestrictedEIRP(8),
|
|
reg9(9),
|
|
reg1058GHz(10),
|
|
reg1158GHz(11),
|
|
reg1254GHzFCCUNII2C(12),
|
|
reg1354GHz(13),
|
|
reg1449GHzPublicSafety(14),
|
|
reg15(15),
|
|
reg1659GHz(16),
|
|
reg1759GHz(17),
|
|
reg1849GHzPublicSafety(18),
|
|
reg1958GHz(19),
|
|
reg2054GHz(20),
|
|
reg2154GHz(21),
|
|
reg2258GHz(22),
|
|
reg23(23),
|
|
reg2458GHz(24),
|
|
reg2558GHzETSI(25),
|
|
reg2654GHzETSI(26),
|
|
reg2758GHz(27),
|
|
reg2858GHz(28),
|
|
reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29),
|
|
reg3054GHz(30),
|
|
reg3158GHz(31),
|
|
reg3249GHzLicensed(32),
|
|
reg3349GHzETSIBroadbandDisasterRelief(33),
|
|
reg3458GHz(34),
|
|
reg3558GHzUnrestrictedEIRP(35),
|
|
reg3654GHz(36),
|
|
reg3758GHz(37),
|
|
reg3852GHzFCCUNII2A(38),
|
|
reg3951GHzETSIBroadbandDisasterRelief(39),
|
|
reg4054GHz(40),
|
|
reg4154GHz(41),
|
|
reg4254GHz(42),
|
|
reg4354GHz(43),
|
|
reg4458GHz(44),
|
|
reg4558GHz(45),
|
|
reg4658GHz(46),
|
|
reg4758GHz(47),
|
|
reg4858GHz(48),
|
|
reg4958GHz(49),
|
|
reg5058GHz(50),
|
|
reg5158GHz(51),
|
|
reg5258GHz(52),
|
|
reg5358GHz(53),
|
|
reg5458GHz(54),
|
|
reg5558GHz(55),
|
|
reg5654GHz(56),
|
|
reg5754GHz(57),
|
|
reg5858GHz(58),
|
|
reg5958GHz(59),
|
|
reg6058GHz(60),
|
|
reg6149GHz(61),
|
|
reg6252GHz(62),
|
|
reg6352GHz(63),
|
|
reg6451GHz(64),
|
|
reg6551GHz(65),
|
|
reg6651GHz(66),
|
|
reg6752GHz(67),
|
|
reg6852GHz(68),
|
|
reg6952GHz(69),
|
|
reg7052GHz(70),
|
|
reg7152GHz(71),
|
|
reg7252GHz(72),
|
|
reg7352GHz(73),
|
|
reg7452GHz(74),
|
|
reg7552GHz(75),
|
|
reg7652GHz(76),
|
|
reg7752GHz(77),
|
|
reg7849GHz(78),
|
|
reg7954GHz(79),
|
|
reg8049GHz(80),
|
|
reg8147GHz(81),
|
|
reg8247GHz(82),
|
|
reg8352GHz(83),
|
|
reg8451GHzFCCUNII1(84),
|
|
reg8552GHzFCCUNII12A(85),
|
|
reg8654GHzFCCUNII2A2C(86),
|
|
reg8758GHz(87),
|
|
reg8849GHz(88),
|
|
reg8949GHz(89),
|
|
reg9054GHzFCCUNII2CParabolicantenna(90),
|
|
reg9152GHzFCCUNII2AParabolicantenna(91),
|
|
reg9251GHzFCCUNII1Parabolicantenna(92),
|
|
reg9349GHz(93),
|
|
reg94(94),
|
|
reg95(95),
|
|
reg96(96),
|
|
reg97(97),
|
|
reg98(98),
|
|
reg99(99),
|
|
reg100(100),
|
|
reg101(101),
|
|
reg102(102),
|
|
reg103(103),
|
|
reg104(104),
|
|
reg105(105),
|
|
reg106(106),
|
|
reg107(107),
|
|
reg108(108),
|
|
reg109(109),
|
|
reg110(110),
|
|
reg111(111),
|
|
reg112(112),
|
|
reg113(113),
|
|
reg114(114),
|
|
reg115(115),
|
|
reg116(116),
|
|
reg117(117),
|
|
reg118(118),
|
|
reg119(119),
|
|
reg120(120),
|
|
reg121(121),
|
|
reg122(122),
|
|
reg123(123),
|
|
reg124(124),
|
|
reg125(125),
|
|
reg126(126),
|
|
reg127(127),
|
|
reg128(128),
|
|
reg129(129),
|
|
reg130(130),
|
|
reg131(131),
|
|
reg132(132),
|
|
reg133(133),
|
|
reg134(134),
|
|
reg135(135),
|
|
reg136(136),
|
|
reg137(137),
|
|
reg138(138),
|
|
reg139(139),
|
|
reg140(140),
|
|
reg141(141),
|
|
reg142(142),
|
|
reg143(143),
|
|
reg144(144),
|
|
reg145(145),
|
|
reg146(146),
|
|
reg147(147),
|
|
reg148(148),
|
|
reg149(149),
|
|
reg150(150),
|
|
reg151(151),
|
|
reg152(152),
|
|
reg153(153),
|
|
reg154(154),
|
|
reg155(155),
|
|
reg156(156),
|
|
reg157(157),
|
|
reg158(158),
|
|
reg159(159),
|
|
reg160(160),
|
|
reg161(161),
|
|
reg162(162),
|
|
reg163(163),
|
|
reg164(164),
|
|
reg165(165),
|
|
reg166(166),
|
|
reg167(167),
|
|
reg168(168),
|
|
reg169(169),
|
|
reg170(170),
|
|
reg171(171),
|
|
reg172(172),
|
|
reg173(173),
|
|
reg174(174),
|
|
reg175(175),
|
|
reg176(176),
|
|
reg177(177),
|
|
reg178(178),
|
|
reg179(179),
|
|
reg180(180),
|
|
reg181(181),
|
|
reg182(182),
|
|
reg183(183),
|
|
reg184(184),
|
|
reg185(185),
|
|
reg186(186),
|
|
reg187(187),
|
|
reg188(188),
|
|
reg189(189),
|
|
reg190(190),
|
|
reg191(191),
|
|
reg192(192),
|
|
reg193(193),
|
|
reg194(194),
|
|
reg195(195),
|
|
reg196(196),
|
|
reg197(197),
|
|
reg198(198),
|
|
reg199(199),
|
|
reg200(200),
|
|
reg201(201),
|
|
reg202(202),
|
|
reg203(203),
|
|
reg204(204),
|
|
reg205(205),
|
|
reg206(206),
|
|
reg207(207),
|
|
reg208(208),
|
|
reg209(209),
|
|
reg210(210),
|
|
reg211(211),
|
|
reg212(212),
|
|
reg213(213),
|
|
reg214(214),
|
|
reg215(215),
|
|
reg216(216),
|
|
reg217(217),
|
|
reg218(218),
|
|
reg219(219),
|
|
reg220(220),
|
|
reg221(221),
|
|
reg222(222),
|
|
reg223(223),
|
|
reg224(224),
|
|
reg225(225),
|
|
reg226(226),
|
|
reg227(227),
|
|
reg228(228),
|
|
reg229(229),
|
|
reg230(230),
|
|
reg231(231),
|
|
reg232(232),
|
|
reg233(233),
|
|
reg234(234),
|
|
reg235(235),
|
|
reg236(236),
|
|
reg237(237),
|
|
reg238(238),
|
|
reg239(239),
|
|
reg240(240),
|
|
reg241(241),
|
|
reg242(242),
|
|
reg243(243),
|
|
reg244(244),
|
|
reg245(245),
|
|
reg246(246),
|
|
reg247(247),
|
|
reg248(248),
|
|
reg249(249),
|
|
reg250(250),
|
|
reg251(251),
|
|
reg252(252),
|
|
reg253(253),
|
|
reg254(254),
|
|
reg255(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regulatory Band prohibits the wireless unit from
|
|
operating outside the regulated limits. An invalid
|
|
Regulatory Band may be caused by a missing or incorrect
|
|
License Key, a corrupt MAC Address or an attempt to
|
|
configure a Regulatory Band not allowed by the License
|
|
Key. NB: a change of state may generate an SNMP trap
|
|
and/or SMTP email alert."
|
|
::= { license 1 }
|
|
|
|
productVariant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pTPxx400Full(0),
|
|
pTPxx400Deprecated1(1),
|
|
pTPxx400Deprecated2(2),
|
|
pTPxx400Lite(3),
|
|
spare1(4),
|
|
pTPxx300(5),
|
|
spare2(6),
|
|
spare3(7),
|
|
pTPxx500FullDeprecated(8),
|
|
pTPxx500LiteDeprecated(9),
|
|
pTPxx500(10),
|
|
pTPxx600Lite(11),
|
|
pTPxx600Full(12),
|
|
pTPxx650(13),
|
|
spare6(14),
|
|
pTP800(15)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The product variant"
|
|
::= { license 2 }
|
|
|
|
productName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the product variant"
|
|
::= { license 3 }
|
|
|
|
frequencyVariant OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
freq5GHz(0),
|
|
freq4GHz(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The hardware frequency variant"
|
|
::= { license 5 }
|
|
|
|
sNMPv3Enable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMPv3 availability control"
|
|
::= { license 9 }
|
|
|
|
licenseVersion OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key version."
|
|
::= { license 12 }
|
|
|
|
licenseUnitSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..11))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit serial number."
|
|
::= { license 13 }
|
|
|
|
licenseIssueNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key issue number for this unit."
|
|
::= { license 15 }
|
|
|
|
licenseCountry OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..103))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The country in which this unit is licensed to operate."
|
|
::= { license 16 }
|
|
|
|
licenseNumberOfRegulatoryBands OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of regulatory bands for which the unit is
|
|
licensed to operate."
|
|
::= { license 17 }
|
|
|
|
licenseBandwidthCap OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The wireless link bandwidth cap in MHz. Zero indicates
|
|
no bandwidth cap."
|
|
::= { license 20 }
|
|
|
|
licenseEncryption OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
aESRijndael(1),
|
|
aES192bitRijndael(2),
|
|
aES256bitRijndael(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key encryption algorithms available."
|
|
::= { license 21 }
|
|
|
|
licenseSecurityLevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
fIPS(1),
|
|
uCAPL(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key security level."
|
|
::= { license 22 }
|
|
|
|
licenseGroupAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key group access setting."
|
|
::= { license 23 }
|
|
|
|
licenseOOBManagementSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key Out-Of-Band (OOB) support setting."
|
|
::= { license 24 }
|
|
|
|
licenseSFPPortSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key Ethernet SFP Port support setting."
|
|
::= { license 25 }
|
|
|
|
licenseAuxiliaryPortSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key Ethernet Auxiliary Port support
|
|
setting."
|
|
::= { license 26 }
|
|
|
|
licenseCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
full(0),
|
|
mid(1),
|
|
lite(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key capacity"
|
|
::= { license 27 }
|
|
|
|
licenseMaxNumberOfTDMChannels OBJECT-TYPE
|
|
SYNTAX INTEGER (0..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key maximum TDM channels setting. Zero
|
|
indicates TDM not available."
|
|
::= { license 28 }
|
|
|
|
licenseIEEE1588Support OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key IEEE-1588 support setting."
|
|
::= { license 29 }
|
|
|
|
licenseSyncESupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key SyncE support setting."
|
|
::= { license 30 }
|
|
|
|
licenseIPv6Support OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key IPv6 support setting."
|
|
::= { license 31 }
|
|
|
|
licenseMinimumFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..23))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum firmware version required to support this
|
|
license key."
|
|
::= { license 32 }
|
|
|
|
licenseFullCapabilityTrialStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
available(0),
|
|
active(1),
|
|
inactive(2),
|
|
expired(3),
|
|
unavailable(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key full capability trial period status."
|
|
::= { license 33 }
|
|
|
|
licenseRemainingTrialPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER (0..31536000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remaining time for the license key full capability
|
|
trial period."
|
|
::= { license 34 }
|
|
|
|
licenseRemainingTrialPeriodAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
fullCapabilityTrialNotActiveOrMoreThan7DaysRemaining(0),
|
|
fullCapabilityTrialExpiringInLessThan7Days(1),
|
|
fullCapabilityTrialExpiringInLessThan6Days(2),
|
|
fullCapabilityTrialExpiringInLessThan5Days(3),
|
|
fullCapabilityTrialExpiringInLessThan4Days(4),
|
|
fullCapabilityTrialExpiringInLessThan3Days(5),
|
|
fullCapabilityTrialExpiringInLessThan2Days(6),
|
|
fullCapabilityTrialExpiringInLessThan1Day(7),
|
|
fullCapabilityTrialHasExpired(8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the full capability trial license period is about to
|
|
expire then purchase a license upgrade from your
|
|
reseller."
|
|
::= { license 35 }
|
|
|
|
capacityVariantMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
mismatchDetected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote node of this link has a lower link capacity.
|
|
Operating with a reduced effective link capacity."
|
|
::= { license 36 }
|
|
|
|
licenseTDDSyncSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key TDD Synchronization support setting."
|
|
::= { license 37 }
|
|
|
|
licenseMaxLinkRange OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1999)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum licensed range for the wireless link in tenths
|
|
of km. A value of zero indicates that the maximum link
|
|
range is not limited by the license."
|
|
::= { license 38 }
|
|
|
|
licenseTrialPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER (0..365)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key maximum trial period, in days."
|
|
::= { license 39 }
|
|
|
|
licenseRARSupport OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
mAB(1),
|
|
dLEP(2),
|
|
mABandDLEP(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The license key Radio Aware Routing support setting."
|
|
::= { license 40 }
|
|
|
|
-- LicenseRegulatoryBandsTable group attribute definitions
|
|
--
|
|
licenseRegulatoryBandsTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"License regulatory bands, used to index the
|
|
LicenseRegulatoryBandsTable."
|
|
::= { licenseRegulatoryBandsTableEntry 1 }
|
|
|
|
licenseRegulatoryBandsList OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
regInvalid(0),
|
|
reg158GHz(1),
|
|
reg258GHz(2),
|
|
reg358GHz(3),
|
|
reg458GHz(4),
|
|
reg558GHz(5),
|
|
reg658GHz(6),
|
|
reg754GHzUnrestrictedEIRPwithDFS(7),
|
|
reg854GHzUnrestrictedEIRP(8),
|
|
reg9(9),
|
|
reg1058GHz(10),
|
|
reg1158GHz(11),
|
|
reg1254GHzFCCUNII2C(12),
|
|
reg1354GHz(13),
|
|
reg1449GHzPublicSafety(14),
|
|
reg15(15),
|
|
reg1659GHz(16),
|
|
reg1759GHz(17),
|
|
reg1849GHzPublicSafety(18),
|
|
reg1958GHz(19),
|
|
reg2054GHz(20),
|
|
reg2154GHz(21),
|
|
reg2258GHz(22),
|
|
reg23(23),
|
|
reg2458GHz(24),
|
|
reg2558GHzETSI(25),
|
|
reg2654GHzETSI(26),
|
|
reg2758GHz(27),
|
|
reg2858GHz(28),
|
|
reg2958GHzUnrestrictedEIRPwithDFSandRTTT(29),
|
|
reg3054GHz(30),
|
|
reg3158GHz(31),
|
|
reg3249GHzLicensed(32),
|
|
reg3349GHzETSIBroadbandDisasterRelief(33),
|
|
reg3458GHz(34),
|
|
reg3558GHzUnrestrictedEIRP(35),
|
|
reg3654GHz(36),
|
|
reg3758GHz(37),
|
|
reg3852GHzFCCUNII2A(38),
|
|
reg3951GHzETSIBroadbandDisasterRelief(39),
|
|
reg4054GHz(40),
|
|
reg4154GHz(41),
|
|
reg4254GHz(42),
|
|
reg4354GHz(43),
|
|
reg4458GHz(44),
|
|
reg4558GHz(45),
|
|
reg4658GHz(46),
|
|
reg4758GHz(47),
|
|
reg4858GHz(48),
|
|
reg4958GHz(49),
|
|
reg5058GHz(50),
|
|
reg5158GHz(51),
|
|
reg5258GHz(52),
|
|
reg5358GHz(53),
|
|
reg5458GHz(54),
|
|
reg5558GHz(55),
|
|
reg5654GHz(56),
|
|
reg5754GHz(57),
|
|
reg5858GHz(58),
|
|
reg5958GHz(59),
|
|
reg6058GHz(60),
|
|
reg6149GHz(61),
|
|
reg6252GHz(62),
|
|
reg6352GHz(63),
|
|
reg6451GHz(64),
|
|
reg6551GHz(65),
|
|
reg6651GHz(66),
|
|
reg6752GHz(67),
|
|
reg6852GHz(68),
|
|
reg6952GHz(69),
|
|
reg7052GHz(70),
|
|
reg7152GHz(71),
|
|
reg7252GHz(72),
|
|
reg7352GHz(73),
|
|
reg7452GHz(74),
|
|
reg7552GHz(75),
|
|
reg7652GHz(76),
|
|
reg7752GHz(77),
|
|
reg7849GHz(78),
|
|
reg7954GHz(79),
|
|
reg8049GHz(80),
|
|
reg8147GHz(81),
|
|
reg8247GHz(82),
|
|
reg8352GHz(83),
|
|
reg8451GHzFCCUNII1(84),
|
|
reg8552GHzFCCUNII12A(85),
|
|
reg8654GHzFCCUNII2A2C(86),
|
|
reg8758GHz(87),
|
|
reg8849GHz(88),
|
|
reg8949GHz(89),
|
|
reg9054GHzFCCUNII2CParabolicantenna(90),
|
|
reg9152GHzFCCUNII2AParabolicantenna(91),
|
|
reg9251GHzFCCUNII1Parabolicantenna(92),
|
|
reg9349GHz(93),
|
|
reg94(94),
|
|
reg95(95),
|
|
reg96(96),
|
|
reg97(97),
|
|
reg98(98),
|
|
reg99(99),
|
|
reg100(100),
|
|
reg101(101),
|
|
reg102(102),
|
|
reg103(103),
|
|
reg104(104),
|
|
reg105(105),
|
|
reg106(106),
|
|
reg107(107),
|
|
reg108(108),
|
|
reg109(109),
|
|
reg110(110),
|
|
reg111(111),
|
|
reg112(112),
|
|
reg113(113),
|
|
reg114(114),
|
|
reg115(115),
|
|
reg116(116),
|
|
reg117(117),
|
|
reg118(118),
|
|
reg119(119),
|
|
reg120(120),
|
|
reg121(121),
|
|
reg122(122),
|
|
reg123(123),
|
|
reg124(124),
|
|
reg125(125),
|
|
reg126(126),
|
|
reg127(127),
|
|
reg128(128),
|
|
reg129(129),
|
|
reg130(130),
|
|
reg131(131),
|
|
reg132(132),
|
|
reg133(133),
|
|
reg134(134),
|
|
reg135(135),
|
|
reg136(136),
|
|
reg137(137),
|
|
reg138(138),
|
|
reg139(139),
|
|
reg140(140),
|
|
reg141(141),
|
|
reg142(142),
|
|
reg143(143),
|
|
reg144(144),
|
|
reg145(145),
|
|
reg146(146),
|
|
reg147(147),
|
|
reg148(148),
|
|
reg149(149),
|
|
reg150(150),
|
|
reg151(151),
|
|
reg152(152),
|
|
reg153(153),
|
|
reg154(154),
|
|
reg155(155),
|
|
reg156(156),
|
|
reg157(157),
|
|
reg158(158),
|
|
reg159(159),
|
|
reg160(160),
|
|
reg161(161),
|
|
reg162(162),
|
|
reg163(163),
|
|
reg164(164),
|
|
reg165(165),
|
|
reg166(166),
|
|
reg167(167),
|
|
reg168(168),
|
|
reg169(169),
|
|
reg170(170),
|
|
reg171(171),
|
|
reg172(172),
|
|
reg173(173),
|
|
reg174(174),
|
|
reg175(175),
|
|
reg176(176),
|
|
reg177(177),
|
|
reg178(178),
|
|
reg179(179),
|
|
reg180(180),
|
|
reg181(181),
|
|
reg182(182),
|
|
reg183(183),
|
|
reg184(184),
|
|
reg185(185),
|
|
reg186(186),
|
|
reg187(187),
|
|
reg188(188),
|
|
reg189(189),
|
|
reg190(190),
|
|
reg191(191),
|
|
reg192(192),
|
|
reg193(193),
|
|
reg194(194),
|
|
reg195(195),
|
|
reg196(196),
|
|
reg197(197),
|
|
reg198(198),
|
|
reg199(199),
|
|
reg200(200),
|
|
reg201(201),
|
|
reg202(202),
|
|
reg203(203),
|
|
reg204(204),
|
|
reg205(205),
|
|
reg206(206),
|
|
reg207(207),
|
|
reg208(208),
|
|
reg209(209),
|
|
reg210(210),
|
|
reg211(211),
|
|
reg212(212),
|
|
reg213(213),
|
|
reg214(214),
|
|
reg215(215),
|
|
reg216(216),
|
|
reg217(217),
|
|
reg218(218),
|
|
reg219(219),
|
|
reg220(220),
|
|
reg221(221),
|
|
reg222(222),
|
|
reg223(223),
|
|
reg224(224),
|
|
reg225(225),
|
|
reg226(226),
|
|
reg227(227),
|
|
reg228(228),
|
|
reg229(229),
|
|
reg230(230),
|
|
reg231(231),
|
|
reg232(232),
|
|
reg233(233),
|
|
reg234(234),
|
|
reg235(235),
|
|
reg236(236),
|
|
reg237(237),
|
|
reg238(238),
|
|
reg239(239),
|
|
reg240(240),
|
|
reg241(241),
|
|
reg242(242),
|
|
reg243(243),
|
|
reg244(244),
|
|
reg245(245),
|
|
reg246(246),
|
|
reg247(247),
|
|
reg248(248),
|
|
reg249(249),
|
|
reg250(250),
|
|
reg251(251),
|
|
reg252(252),
|
|
reg253(253),
|
|
reg254(254),
|
|
reg255(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of regulatory bands for which the unit is
|
|
licensed to operate. A regulatory band prohibits the
|
|
wireless unit from operating outside the regulated
|
|
limits. An invalid regulatory band indicates a corrupted
|
|
license key. NB: a change of state may generate an SNMP
|
|
trap and/or SMTP email alert."
|
|
::= { licenseRegulatoryBandsTableEntry 2 }
|
|
|
|
-- Management group attribute definitions
|
|
--
|
|
targetRange OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Initial target range used in installation +/-1,
|
|
expressed in tenths of a kilometer. When Auto-Ranging
|
|
this must be set to 0"
|
|
::= { management 1 }
|
|
|
|
rangingMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto0to40km(0),
|
|
auto0to100km(1),
|
|
auto0to200km(2),
|
|
targetRange(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of ranging to use during installation, either
|
|
Auto-Ranging or use a selectable Target Range"
|
|
::= { management 2 }
|
|
|
|
installStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
wrongPeer(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-zero value indicates that signalling was received
|
|
with the wrong MAC address or a mismatched link name. NB:
|
|
It is very unusual to detect this, because units with
|
|
mis-configured Target MAC Address will normally fail to
|
|
establish a wireless link. However, rare circumstances
|
|
may establish a partial wireless link and detect this
|
|
situation. NB: A non-zero value on start-up, or a change
|
|
of value during operation, may generate an SNMP trap
|
|
and/or SMTP email alert"
|
|
::= { management 3 }
|
|
|
|
installArmState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disarmed(0),
|
|
armed(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the unit is being installed. NB: a change
|
|
of state may generate an SNMP trap and/or SMTP email
|
|
alert"
|
|
::= { management 4 }
|
|
|
|
tFTPServerPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number of the TFTP Server from which the TFTP
|
|
Software Upgrade File Name will be retrieved"
|
|
::= { management 6 }
|
|
|
|
tFTPSoftwareUpgradeFileName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Filename of the Software Upgrade to be loaded from the
|
|
TFTP Server"
|
|
::= { management 7 }
|
|
|
|
tFTPStartSoftwareUpgrade OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Write '1' to this attribute to start the TFTP software
|
|
upgrade process. The attribute will be reset to 0 when
|
|
the upgrade process has finished. Continuing with the
|
|
software upgrade will cause spectrum management (DSO)
|
|
channel metrics collection to stop. The wireless unit
|
|
will no longer search for the optimal operational radio
|
|
channel. The performance of this wireless link may
|
|
deterioate over time. If operating in a regulatory band
|
|
where RADAR detection is mandatory you must complete the
|
|
software upgrade and reboot the unit. Channel metrics
|
|
collection will only be restarted after the wireless unit
|
|
has been rebooted"
|
|
::= { management 8 }
|
|
|
|
tFTPSoftwareUpgradeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(0),
|
|
uploadinprogress(1),
|
|
uploadsuccessfulprogrammingFLASH(2),
|
|
upgradesuccessfulreboottorunthenewsoftwareimage(3),
|
|
upgradefailed(4),
|
|
upgradewarning(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current status of the TFTP Software upgrade process"
|
|
::= { management 9 }
|
|
|
|
tFTPSoftwareUpgradeStatusText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Descriptive text describing the status of the TFTP
|
|
Software upgrade process, including any error details"
|
|
::= { management 10 }
|
|
|
|
tFTPSoftwareUpgradeStatusAdditionalText OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Any additional text describing the status of the TFTP
|
|
Software upgrade process, including any error details"
|
|
::= { management 11 }
|
|
|
|
hTTPAccessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether or not HTTP access is enabled,
|
|
i.e. if this is disabled (0) then the unit will not
|
|
respond to any requests on the HTTP port. Remote
|
|
management via HTTPS is not affected by this setting. Any
|
|
change in this setting will not take effect until the
|
|
unit has been rebooted. (Factory default = Enabled)"
|
|
::= { management 12 }
|
|
|
|
telnetAccessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether or not Telnet access is enabled,
|
|
i.e. if this is disabled (0) then the unit will not
|
|
respond to any requests on the TELNET port. Any change in
|
|
this setting will not take effect until the unit has been
|
|
rebooted. (Factory default = Disabled)"
|
|
::= { management 13 }
|
|
|
|
hTTPPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls the port number for HTTP access. A value
|
|
of zero will use the default port number. Any change in
|
|
this setting will not take effect until the unit has been
|
|
rebooted. (Factory default = 80)"
|
|
::= { management 14 }
|
|
|
|
hTTPSPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls the port number for HTTPS access. A value
|
|
of zero will use the default port number. Availability of
|
|
HTTPS is controlled via the License Key. Any change in
|
|
this setting will not take effect until the unit has been
|
|
rebooted. (Factory default = 443)"
|
|
::= { management 15 }
|
|
|
|
telnetPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls the port number for TELNET access. A value
|
|
of zero will use the default port number. Any change in
|
|
this setting will not take effect until the unit has been
|
|
rebooted. (Factory default = 23)"
|
|
::= { management 16 }
|
|
|
|
hTTPSAccessEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether or not HTTPS access is enabled,
|
|
i.e. if this is disabled (0) then the unit will not
|
|
respond to any requests on the HTTPS port. Remote
|
|
management via HTTP is not affected by this setting. Any
|
|
change in this setting will not take effect until the
|
|
unit has been rebooted. (Factory default = Enabled)"
|
|
::= { management 17 }
|
|
|
|
tFTPServerInternetAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ipv4(1),
|
|
ipv6(2),
|
|
ipv4z(3),
|
|
ipv6z(4),
|
|
unknown6(5),
|
|
unknown7(6),
|
|
unknown8(7),
|
|
unknown9(8),
|
|
unknown10(9),
|
|
unknown11(10),
|
|
unknown12(11),
|
|
unknown13(12),
|
|
unknown14(13),
|
|
unknown15(14),
|
|
unknown16(15),
|
|
dns(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Internet address specified by the associated
|
|
tFTPServerInternetAddress."
|
|
::= { management 18 }
|
|
|
|
tFTPServerInternetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"INET address of the TFTP Server from which the TFTP
|
|
Software Upgrade File Name will be retrieved"
|
|
::= { management 19 }
|
|
|
|
lowestDataModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest modulation mode at which Ethernet Data
|
|
traffic will be bridged over the wireless link"
|
|
::= { management 20 }
|
|
|
|
lowestSecondDataModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The lowest modulation mode at which Second Data Service
|
|
Ethernet traffic will be bridged over the wireless link"
|
|
::= { management 21 }
|
|
|
|
-- PhyControl group attribute definitions
|
|
--
|
|
linkSymmetry OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
symmetryAdaptive(0),
|
|
symmetry2to1(1),
|
|
symmetry1to1(2),
|
|
symmetry1to2(3),
|
|
symmetry3to1(4),
|
|
symmetry1to3(5),
|
|
symmetry5to1(6),
|
|
symmetry1to5(7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Provides configuration options for sharing the available
|
|
wireless capacity between the transmit and receive
|
|
directions. Fixed link symmetry is defined by a ratio of
|
|
the burst duration for the transmit direction to the
|
|
burst duration for the receive direction. Permitted
|
|
settings are 5:1, 3:1, 2:1, 1:1, 1:2, 1:3, 1:5. The 1:1
|
|
option provides fixed symmetric operation. The adaptive
|
|
option selects transmit and receive burst durations
|
|
automatically in response to the offered Ethernet traffic
|
|
in each link direction. This attribute is valid only for
|
|
a unit configured as a TDD Master"
|
|
::= { phyControl 1 }
|
|
|
|
userConfiguredMaxModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modBpsk63percent(0),
|
|
modQpsk63percent(1),
|
|
modQpsk87percent(2),
|
|
mod16qam63percent(3),
|
|
mod16qam87percent(4),
|
|
mod64qam75percent(5),
|
|
mod64qam92percent(6),
|
|
mod256qam81percent(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum receive modulation mode controls the MAX
|
|
mode used for adaptive modulation. NOTE: This attribute
|
|
is automatically disabled when the installation agent is
|
|
armed. To disarm the installation agent use the
|
|
installation wizard"
|
|
::= { phyControl 2 }
|
|
|
|
linkModeOptimization OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
iPTraffic(0),
|
|
tDMTraffic(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Optimizes the wireless link behavior for the type of
|
|
traffic to be carried. In 'IP Traffic' mode, the wireless
|
|
link will minimize transmission errors by automatically
|
|
adapting the modulation mode. In 'TDM Traffic' mode, the
|
|
wireless link will minimize transmission latency and
|
|
preserve throughput by maintaining a higher modulation
|
|
mode in the presence of a limited number of errors. The
|
|
'TDM Traffic' mode is recommended for E1/T1 applications
|
|
and connectionless protocols."
|
|
::= { phyControl 3 }
|
|
|
|
txColorCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
a(0),
|
|
b(1),
|
|
c(2),
|
|
d(3),
|
|
e(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit Color Code. This attribute need only be
|
|
considered when the unit is installed in a network of PTP
|
|
units and where some of the units are operating on the
|
|
same frequency. In this case, the value would normally be
|
|
derived by a network planner. In all other cases, it is
|
|
recommended that this attribute is left at the default
|
|
value. NOTE: For the link to operate, the value of this
|
|
parameter must in all cases match the value of the Rx
|
|
Color Code parameter at the far end of the link."
|
|
::= { phyControl 4 }
|
|
|
|
rxColorCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
a(0),
|
|
b(1),
|
|
c(2),
|
|
d(3),
|
|
e(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive Color Code. This attribute need only be
|
|
considered when the unit is installed in a network of PTP
|
|
units and where some of the units are operating on the
|
|
same frequency. In this case, the value would normally be
|
|
derived by a network planner. In all other cases, it is
|
|
recommended that this attribute is left at the default
|
|
value. NOTE: For the link to operate, the value of this
|
|
parameter must in all cases match the value of the Tx
|
|
Color Code parameter at the far end of the link."
|
|
::= { phyControl 5 }
|
|
|
|
remoteMaximumTransmitPower OBJECT-TYPE
|
|
SYNTAX INTEGER (-15..30)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum transmit power the remote wireless unit is
|
|
permitted to use when establishing and maintaining the
|
|
wireless link"
|
|
::= { phyControl 6 }
|
|
|
|
-- PhyStatus group attribute definitions
|
|
--
|
|
linkLoss OBJECT-TYPE
|
|
SYNTAX INTEGER (-500..500)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The wireless link loss expressed in tenths of a dB"
|
|
::= { phyStatus 1 }
|
|
|
|
receivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Receive power expressed in tenths of a dBm"
|
|
::= { phyStatus 2 }
|
|
|
|
vectorError OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vector error measurement compares the received
|
|
signal's IQ modulation characteristics to an ideal signal
|
|
to determine the composite error vector magnitude. The
|
|
value represented by this attribute is the average vector
|
|
error over the previous second expressed in tenths of a
|
|
dB"
|
|
::= { phyStatus 3 }
|
|
|
|
transmitPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transmit power expressed in tenths of a dBm"
|
|
::= { phyStatus 4 }
|
|
|
|
receiveChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current active receive channel"
|
|
::= { phyStatus 5 }
|
|
|
|
transmitChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..63)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current active transmit channel"
|
|
::= { phyStatus 6 }
|
|
|
|
receiveFreqMHz OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6050)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current receive frequency expressed in integer MHz"
|
|
::= { phyStatus 7 }
|
|
|
|
transmitFreqMHz OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6050)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current transmit frequency expressed in integer MHz"
|
|
::= { phyStatus 8 }
|
|
|
|
signalStrengthRatio OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Signal strength ratio (Vertical / Horizontal) : the
|
|
number of dB larger the Vertical antenna input is than
|
|
the Horizontal antenna input expressed in tenths of a dB"
|
|
::= { phyStatus 9 }
|
|
|
|
receiveFreqKHz OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6050000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current receive frequency expressed as KHz"
|
|
::= { phyStatus 10 }
|
|
|
|
transmitFreqKHz OBJECT-TYPE
|
|
SYNTAX INTEGER (0..6050000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current transmit frequency expressed as KHz"
|
|
::= { phyStatus 11 }
|
|
|
|
rawReceivePower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Raw receive power expressed in tenths of a dBm"
|
|
::= { phyStatus 12 }
|
|
|
|
range OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Distance between the two peer wireless units expressed
|
|
in tenths of a kilometer"
|
|
::= { phyStatus 13 }
|
|
|
|
receiveModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current active receive modulation mode"
|
|
::= { phyStatus 14 }
|
|
|
|
transmitModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current active transmit modulation mode"
|
|
::= { phyStatus 15 }
|
|
|
|
searchState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
registering(0),
|
|
searching(1),
|
|
acquiring(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Search status of the wireless modem. 'Registering' means
|
|
that the modem has locked to an OFDM signal, and the
|
|
wireless link is up. 'Searching' means that no wireless
|
|
signal has been detected. 'Acquiring' means that a
|
|
wireless signal has been detected, but the modem has not
|
|
locked to an OFDM signal."
|
|
::= { phyStatus 16 }
|
|
|
|
-- Alarms group attribute definitions
|
|
--
|
|
unitOutOfCalibration OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
calibrated(0),
|
|
partialCalibration(1),
|
|
invalidCalibration(2),
|
|
bandwidthvariantunsupportedPAsShutdown(3),
|
|
outOfCalibrationPAsShutdown(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit is out of calibration"
|
|
::= { alarms 1 }
|
|
|
|
incompatibleRegulatoryBands OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
regOK(0),
|
|
regIncompatibleLicenseKeys(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The master and slave units have incompatible regulatory
|
|
bands. NB: Both units must have compatible license keys"
|
|
::= { alarms 4 }
|
|
|
|
noWirelessChannelAvailable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
noWirelessChannelAvailable(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spectrum Management was unable to locate a suitable
|
|
wireless channel to operate on"
|
|
::= { alarms 5 }
|
|
|
|
wirelessLinkDisabledWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
disabledBySNMPifAdminStatus(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the wireless interface has
|
|
disabled wireless traffic"
|
|
::= { alarms 6 }
|
|
|
|
mainPSUPortDisabledWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
disabledBySNMPifAdminStatus(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { alarms 7 }
|
|
|
|
sFPError OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
installedSFPNotLicensed(1),
|
|
fiberLinkNotEstablishedButLOSNotDetected(2),
|
|
fiberLinkNotEstablishedAndLOSDetected(3),
|
|
installedSFPNotSupported(4),
|
|
sFPInitializationFailed(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the SFP link is not OK, there are five possible
|
|
causes: Either a SFP has been installed but the license
|
|
key does not include SFP fiber support, a fiber link
|
|
could not be established even though no LOS was detected
|
|
(i.e. an optical carrier was detected, which could be due
|
|
to a broken TX fiber, or because the link is disabled at
|
|
the fiber link partner), a fiber link could not be
|
|
established and LOS is detected (i.e. no optical carrier
|
|
is detected), the installed SFP is not supported or the
|
|
installed SFP failed to initialize correctly. NB: a
|
|
change of status may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { alarms 8 }
|
|
|
|
mainPSUPortConfigurationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
mismatchDetected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch"
|
|
::= { alarms 9 }
|
|
|
|
incompatibleMasterAndSlave OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
incompatibleProductVariants(1),
|
|
differentSoftwareVersionsRunning(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-zero value indicates that the master and slave
|
|
ends of a link are different hardware products, or have
|
|
different software versions. NB: It is very unusual to
|
|
detect this, because incompatible units will normally
|
|
fail to establish a wireless link. However, some
|
|
combinations may establish a partial wireless link and
|
|
detect this situation. NB: A non-zero value may generate
|
|
an SNMP trap and/or SMTP email alert"
|
|
::= { alarms 10 }
|
|
|
|
tDDSynchronizationStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
locked(0),
|
|
holdover(1),
|
|
holdoverNoGPSSyncIn(2),
|
|
notSynchronized(3),
|
|
notSynchronizedNoGPSSyncIn(4),
|
|
pTPSYNCNotConnected(5),
|
|
initialising(6),
|
|
clusterTimingMaster(7),
|
|
acquiringLock(8),
|
|
inactive(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An alarm value (displayed in red) indicates that one of
|
|
the following conditions has not been met (i) An external
|
|
timing system is connected or internal timing has been
|
|
configured. (ii) The timing system is providing a useable
|
|
reference. (iii) The ODU is locked to this reference."
|
|
::= { alarms 11 }
|
|
|
|
auxPortDisabledWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
disabledBySNMPifAdminStatus(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { alarms 12 }
|
|
|
|
tDDSynchronizationAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
synchronizationLost(1),
|
|
referenceSignalLost(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Not Synchronized indicates failure of the external
|
|
timing system for a period greater than the holdover
|
|
timer. TDD frame timing will have drifted, and this link
|
|
may cause interference with other links in a synchronized
|
|
network. Timing System Failure is an early warning,
|
|
indicating that 80% of the holdover period has expired."
|
|
::= { alarms 13 }
|
|
|
|
linkModeOptimizationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
linkModeOptimizationMismatch(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote node of this link has been configured with a
|
|
different link mode optimization"
|
|
::= { alarms 14 }
|
|
|
|
auxPortConfigurationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
mismatchDetected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch. This
|
|
alarm is only raised if an Out-of-Band Management Mode
|
|
has been configured."
|
|
::= { alarms 15 }
|
|
|
|
secureModeAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
secureModeIsActive(0),
|
|
secureModeIsNotConfigured(1),
|
|
secureModeIsConfiguredButNotActive(2),
|
|
secureModeIsNotSupported(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
|
|
The secure mode is not configured(1) state indicates that
|
|
the unit is capable of secure mode operation, and one or
|
|
more of the following security materials has not been
|
|
configured: Key Of Keys, Private Key, Public Certificate,
|
|
DRNG Entropy Status, Wireless Encryption Key. The secure
|
|
mode mode is configured but not active(2) state indicates
|
|
that the unit is capable of secure mode operation, and
|
|
the security material has been configured, but the
|
|
configuration of interfaces is not consistent with secure
|
|
mode operation. The secure mode is not supported(3) state
|
|
indicates that the unit is not capable of secure mode
|
|
operation. The secure mode capability requires
|
|
appropriate hardware compatibility, license key and
|
|
software image."
|
|
::= { alarms 16 }
|
|
|
|
dataBridgingStatusAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bridgingEnabled(0),
|
|
bridgingDisabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet Data traffic bridging is disabled because the
|
|
wireless link is not operating at the configured Lowest
|
|
Data Modulation Mode"
|
|
::= { alarms 17 }
|
|
|
|
sFPPortDisabledWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
disabledBySNMPifAdminStatus(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { alarms 18 }
|
|
|
|
sFPPortConfigurationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
mismatchDetected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch. This
|
|
alarm is only raised if an Out-of-Band Management Mode
|
|
has been configured."
|
|
::= { alarms 19 }
|
|
|
|
maxLinkRangeExceeded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
maxLinkRangeOK(0),
|
|
maxLinkRangeExceeded(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured link range is greater than the maximum
|
|
allowed by the license key. The link will operate at a
|
|
reduced capacity while this condition applies. This alarm
|
|
is only raised if the license specifies a maximum link
|
|
range and the trial license is not active."
|
|
::= { alarms 20 }
|
|
|
|
nIDULanPortDisabledWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
disabledBySNMPifAdminStatus(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { alarms 21 }
|
|
|
|
nIDULanPortConfigurationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(0),
|
|
mismatchDetected(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch."
|
|
::= { alarms 22 }
|
|
|
|
portAllocationMismatch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
portAllocationOK(0),
|
|
mismatchinSecondDataService(1),
|
|
mismatchinOutofBandRemoteManagementService(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local and remote ODUs have different services
|
|
configured."
|
|
::= { alarms 23 }
|
|
|
|
secondDataBridgingStatusAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
bridgingEnabled(0),
|
|
bridgingDisabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridging of Ethernet traffic from Second Data Service
|
|
has been disabled because the wireless link is not
|
|
operating at the configured Lowest Second Data Modulation
|
|
Mode"
|
|
::= { alarms 24 }
|
|
|
|
transparentClockSourcePortAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
invalidTransparentClockSourcePort(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transparent Clock will not function properly because
|
|
SFP, the selected clock source port is not FIBER"
|
|
::= { alarms 25 }
|
|
|
|
-- Smtp group attribute definitions
|
|
--
|
|
sMTPEmailAlert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Simple Mail Transfer Protocol is used to send equipment
|
|
alerts via email to a specified email address"
|
|
::= { smtp 1 }
|
|
|
|
sMTPServerPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port number of the SMTP server"
|
|
::= { smtp 3 }
|
|
|
|
sMTPSourceEmailAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 'from' email address used when constructing the
|
|
automatically generated e-mail message"
|
|
::= { smtp 4 }
|
|
|
|
sMTPDestinationEmailAddress OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The 'to' email address used when constructing the
|
|
automatically generated e-mail message"
|
|
::= { smtp 5 }
|
|
|
|
sMTPEnabledMessages OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
nIDULanPortUpDown(0),
|
|
sFPPortUpDown(1),
|
|
auxPortUpDown(2),
|
|
mainPSUPortUpDown(3),
|
|
enabledDiagnosticAlarms(4),
|
|
dFSImpulseInterference(5),
|
|
channelChange(6),
|
|
wirelessLinkUpDown(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls which SMTP messages the unit will send"
|
|
::= { smtp 6 }
|
|
|
|
sMTPServerInternetAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ipv4(1),
|
|
ipv6(2),
|
|
ipv4z(3),
|
|
ipv6z(4),
|
|
unknown6(5),
|
|
unknown7(6),
|
|
unknown8(7),
|
|
unknown9(8),
|
|
unknown10(9),
|
|
unknown11(10),
|
|
unknown12(11),
|
|
unknown13(12),
|
|
unknown14(13),
|
|
unknown15(14),
|
|
unknown16(15),
|
|
dns(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Internet address specified by the associated
|
|
sMTPServerInternetAddress."
|
|
::= { smtp 7 }
|
|
|
|
sMTPServerInternetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Internet address of the SMTP server"
|
|
::= { smtp 8 }
|
|
|
|
-- SnmpControl group attribute definitions
|
|
--
|
|
sNMPPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP port number used to access the SNMP MIB (i.e.
|
|
Gets and Sets) (default = 161). NB: A system reboot is
|
|
required to activate changes to this attribute"
|
|
::= { snmpControl 1 }
|
|
|
|
sNMPCommunityString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP community string. NB: A system reboot is
|
|
required to activate changes to this attribute"
|
|
::= { snmpControl 2 }
|
|
|
|
sNMPTrapTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the sNMPTrapTable."
|
|
::= { snmpControl 3 }
|
|
|
|
sNMPTrapVersion OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
v1(0),
|
|
v2c(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP protocol version to use for SNMP Traps. NB: A
|
|
system reboot is required to activate changes to this
|
|
attribute"
|
|
::= { snmpControl 5 }
|
|
|
|
sNMPEnabledTraps OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
auxPortUpDown(0),
|
|
mainPSUPortUpDown(1),
|
|
authenticationFailure(2),
|
|
enabledDiagnosticAlarms(3),
|
|
dFSImpulseInterference(4),
|
|
channelChange(5),
|
|
wirelessLinkUpDown(6),
|
|
coldStart(7),
|
|
nIDULanPortUpDown(14),
|
|
sFPPortUpDown(15)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls which SNMP Traps the unit will send"
|
|
::= { snmpControl 6 }
|
|
|
|
enabledDiagnosticAlarms OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
portState(0),
|
|
incompatibleMasterAndSlave(1),
|
|
incompatibleRegulatoryBands(2),
|
|
maximumLinkRangeExceeded(3),
|
|
unitOutOfCalibration(4),
|
|
installArmState(5),
|
|
installStatus(6),
|
|
regulatoryBand(7),
|
|
syslogLocalWrapped(8),
|
|
syslogLocalNearlyFull(9),
|
|
syslogDisabledWarning(10),
|
|
linkModeOptimizationMismatch(11),
|
|
tDDSynchronizationAlarm(12),
|
|
wirelessLinkDisabledWarning(13),
|
|
sNTPSynchronizationFailed(14),
|
|
noWirelessChannelAvailable(15),
|
|
tDMAlarms(18),
|
|
capacityVariantMismatch(19),
|
|
remainingFullCapacityTrialTime(20),
|
|
dataBridgingStatus(21),
|
|
unknown18(22),
|
|
syslogClientDisabledWarning(23)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls which individual diagnostic alarms are enabled.
|
|
The unit may be configured to generate SNMP traps and/or
|
|
SMTP email alerts for these enabled alarms by selecting
|
|
'Enabled Diagnostic Alarms' on the 'SNMP Enabled Traps'
|
|
and/or 'SMTP Enabled Messages' attributes"
|
|
::= { snmpControl 7 }
|
|
|
|
sNMPSendAllTrapsAtStartup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controls whether cleared traps are reported at start-up
|
|
as well as raised traps. Only enabled traps will be
|
|
reported. NB: Traps corresponding to transient events
|
|
(i.e. not associated with an alarm or status value) are
|
|
only sent when required and not at start-up."
|
|
::= { snmpControl 8 }
|
|
|
|
-- SNMPTrapTable group attribute definitions
|
|
--
|
|
sNMPTrapTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP trap value, used to index the SNMPTrapTable."
|
|
::= { sNMPTrapTableEntry 1 }
|
|
|
|
sNMPTrapPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination port for SNMP Traps (default=162). NB: A
|
|
system reboot is required to activate changes to this
|
|
attribute."
|
|
::= { sNMPTrapTableEntry 3 }
|
|
|
|
sNMPTrapInternetAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ipv4(1),
|
|
ipv6(2),
|
|
ipv4z(3),
|
|
ipv6z(4),
|
|
unknown6(5),
|
|
unknown7(6),
|
|
unknown8(7),
|
|
unknown9(8),
|
|
unknown10(9),
|
|
unknown11(10),
|
|
unknown12(11),
|
|
unknown13(12),
|
|
unknown14(13),
|
|
unknown15(14),
|
|
unknown16(15),
|
|
dns(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Internet address specified by the associated
|
|
sNMPTrapInternetAddress."
|
|
::= { sNMPTrapTableEntry 4 }
|
|
|
|
sNMPTrapInternetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Internet address to which all SNMP Traps are sent."
|
|
::= { sNMPTrapTableEntry 5 }
|
|
|
|
sNMPTrapReceiverEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value of 0 disables the sending of SNMP trap to
|
|
corresponding receiver. A value of 1 enables the sending
|
|
of SNMP trap to corresponding receiver."
|
|
::= { sNMPTrapTableEntry 6 }
|
|
|
|
-- Sntp group attribute definitions
|
|
--
|
|
sNTPState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNTP control state"
|
|
::= { sntp 1 }
|
|
|
|
sNTPPollInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (60..43200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNTP server polling interval"
|
|
::= { sntp 4 }
|
|
|
|
sNTPSync OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noSync(0),
|
|
inSync(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If SNTP Sync fails then check the server settings in the
|
|
Remote Management page, or disable SNTP"
|
|
::= { sntp 5 }
|
|
|
|
sNTPLastSync OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Last SNTP sync time"
|
|
::= { sntp 6 }
|
|
|
|
systemClock OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System clock presented as local time"
|
|
::= { sntp 7 }
|
|
|
|
timeZone OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
gmtMinus1200(0),
|
|
gmtMinus1130(1),
|
|
gmtMinus1100(2),
|
|
gmtMinus1030(3),
|
|
gmtMinus1000(4),
|
|
gmtMinus0930(5),
|
|
gmtMinus0900(6),
|
|
gmtMinus0830(7),
|
|
gmtMinus0800(8),
|
|
gmtMinus0730(9),
|
|
gmtMinus0700(10),
|
|
gmtMinus0630(11),
|
|
gmtMinus0600(12),
|
|
gmtMinus0530(13),
|
|
gmtMinus0500(14),
|
|
gmtMinus0430(15),
|
|
gmtMinus0400(16),
|
|
gmtMinus0330(17),
|
|
gmtMinus0300(18),
|
|
gmtMinus0230(19),
|
|
gmtMinus0200(20),
|
|
gmtMinus0130(21),
|
|
gmtMinus0100(22),
|
|
gmtMinus0030(23),
|
|
gmtZero(24),
|
|
gmtPlus0030(25),
|
|
gmtPlus0100(26),
|
|
gmtPlus0130(27),
|
|
gmtPlus0200(28),
|
|
gmtPlus0230(29),
|
|
gmtPlus0300(30),
|
|
gmtPlus0330(31),
|
|
gmtPlus0400(32),
|
|
gmtPlus0430(33),
|
|
gmtPlus0500(34),
|
|
gmtPlus0530(35),
|
|
gmtPlus0600(36),
|
|
gmtPlus0630(37),
|
|
gmtPlus0700(38),
|
|
gmtPlus0730(39),
|
|
gmtPlus0800(40),
|
|
gmtPlus0830(41),
|
|
gmtPlus0900(42),
|
|
gmtPlus0930(43),
|
|
gmtPlus1000(44),
|
|
gmtPlus1030(45),
|
|
gmtPlus1100(46),
|
|
gmtPlus1130(47),
|
|
gmtPlus1200(48),
|
|
gmtPlus1230(49),
|
|
gmtPlus1300(50)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time zone offsets from Greenwich Mean Time (GMT)"
|
|
::= { sntp 8 }
|
|
|
|
daylightSaving OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Daylight Saving Time"
|
|
::= { sntp 9 }
|
|
|
|
sNTPPrimaryServer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
server1(0),
|
|
server2(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the primary SNTP server, determining the order
|
|
in which the servers are tried."
|
|
::= { sntp 10 }
|
|
|
|
sNTPPrimaryServerDeadTime OBJECT-TYPE
|
|
SYNTAX INTEGER (0..86400)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time (in seconds) to wait before retrying communications
|
|
with an unresponsive primary SNTP server. Setting the
|
|
value to 0 disables the timer."
|
|
::= { sntp 11 }
|
|
|
|
sNTPServerRetries OBJECT-TYPE
|
|
SYNTAX INTEGER (0..10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of times the PTP will retry after an SNTP server
|
|
fails to respond."
|
|
::= { sntp 12 }
|
|
|
|
sNTPServerTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (1..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time (in seconds) the PTP will wait for a response from
|
|
an SNTP server."
|
|
::= { sntp 13 }
|
|
|
|
sNTPServerTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the SNTPServerTable."
|
|
::= { sntp 14 }
|
|
|
|
-- SNTPServerTable group attribute definitions
|
|
--
|
|
sNTPServerTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index range for the SNTPServerTable."
|
|
::= { sNTPServerTableEntry 1 }
|
|
|
|
sNTPServerPortNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP port number of the SNTP server. Defaults to port
|
|
123."
|
|
::= { sNTPServerTableEntry 3 }
|
|
|
|
sNTPServerStatus OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..127))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status message reflecting the result of communications
|
|
with the SNTP server when last polled"
|
|
::= { sNTPServerTableEntry 4 }
|
|
|
|
sNTPServerInternetAddressType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
ipv4(1),
|
|
ipv6(2),
|
|
ipv4z(3),
|
|
ipv6z(4),
|
|
unknown6(5),
|
|
unknown7(6),
|
|
unknown8(7),
|
|
unknown9(8),
|
|
unknown10(9),
|
|
unknown11(10),
|
|
unknown12(11),
|
|
unknown13(12),
|
|
unknown14(13),
|
|
unknown15(14),
|
|
unknown16(15),
|
|
dns(16)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Internet address specified by the associated
|
|
sNTPServerInternetAddress."
|
|
::= { sNTPServerTableEntry 5 }
|
|
|
|
sNTPServerInternetAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Internet address of a valid SNTP server"
|
|
::= { sNTPServerTableEntry 6 }
|
|
|
|
-- Reset group attribute definitions
|
|
--
|
|
systemReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
running(0),
|
|
consoleReboot(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to '1' will cause a system
|
|
reboot. NB: a system reboot will apply any pending new
|
|
settings held in memory"
|
|
::= { reset 1 }
|
|
|
|
-- Versions group attribute definitions
|
|
--
|
|
softwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current software version"
|
|
::= { versions 1 }
|
|
|
|
hardwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hardware platform version"
|
|
::= { versions 2 }
|
|
|
|
secondarySoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Secondary software version, used when the primary
|
|
software image is invalid or erased"
|
|
::= { versions 3 }
|
|
|
|
bootVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..63))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Boot code software version"
|
|
::= { versions 4 }
|
|
|
|
-- PubStats group attribute definitions
|
|
--
|
|
receiveDataRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average data rate over the last one second interval
|
|
(kbps)"
|
|
::= { pubStats 1 }
|
|
|
|
transmitDataRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average data rate over the last one second interval
|
|
(kbps)"
|
|
::= { pubStats 2 }
|
|
|
|
aggregateDataRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average data rate over the last one second interval
|
|
(kbps)"
|
|
::= { pubStats 3 }
|
|
|
|
wirelessLinkAvailability OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link availability calculated since the last reset of the
|
|
system counters, as a percentage multiplied by 10000 to
|
|
give four decimal places of precision"
|
|
::= { pubStats 4 }
|
|
|
|
wirelessLinkStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(0),
|
|
registering(1),
|
|
searching(2),
|
|
acquiring(3),
|
|
radarCAC(4),
|
|
initialising(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the wireless link"
|
|
::= { pubStats 5 }
|
|
|
|
byteErrorRatio OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reciprocal of the byte error ratio calculated since the
|
|
last reset of the system counters"
|
|
::= { pubStats 6 }
|
|
|
|
receiveModulationModeDetail OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
runningAtMaximumReceiveMode(0),
|
|
runningAtUserConfiguredMaxModulationMode(1),
|
|
restrictedBecauseInstallationIsArmed(2),
|
|
restrictedBecauseOfByteErrorsOnTheWirelessLink(3),
|
|
restrictedBecauseTheLinkParametersAreUpdating(4),
|
|
restrictedBecauseChannelChangeIsInProgress(5),
|
|
restrictedDueToTheLowEthernetLinkSpeed(6),
|
|
runningAtMaximumReceiveModeForChannelBandwidth(7),
|
|
limitedByTheWirelessConditions(8),
|
|
restrictedBecauseFullCapabilityTrialLicenseExpired(9)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The reason for the current receive modulation mode"
|
|
::= { pubStats 7 }
|
|
|
|
dataBridgingAvailability OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Link availability bridging Ethernet Data traffic
|
|
calculated since the last reset of the system counters,
|
|
as a percentage multiplied by 10000 to give four decimal
|
|
places of precision"
|
|
::= { pubStats 8 }
|
|
|
|
-- Encryption group attribute definitions
|
|
--
|
|
encryptionAlgorithm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(0),
|
|
aESRijndael(1),
|
|
aES192bitRijndael(2),
|
|
aES256bitRijndael(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Encryption Algorithm used by the wireless link. NB:
|
|
A system reboot is required to activate changes to this
|
|
attribute. NB: The same Encryption Algorithm must be
|
|
configured at BOTH ends of the link for it to function
|
|
correctly"
|
|
::= { encryption 1 }
|
|
|
|
-- TDDControl group attribute definitions
|
|
--
|
|
tDDSynchronizationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TDD Synchronization Mode selection"
|
|
::= { tDDControl 1 }
|
|
|
|
-- AAAControl group attribute definitions
|
|
--
|
|
userTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of entries in the userTable"
|
|
::= { aAAControl 1 }
|
|
|
|
-- UserTable group attribute definitions
|
|
--
|
|
userTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"used to index values in the userTable."
|
|
::= { userTableEntry 1 }
|
|
|
|
userName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..67))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User name which must be entered, along with the
|
|
appropriate password, in order to gain access to the
|
|
system."
|
|
::= { userTableEntry 2 }
|
|
|
|
userRole OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
readOnly(0),
|
|
systemAdministrator(1),
|
|
securityOfficer(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Role of the selected user. A Security Officer has access
|
|
to and can modify all settings. A System Administrator
|
|
has access to and can modify all non-security settings. A
|
|
Read Only user can view settings, but cannot make any
|
|
changes."
|
|
::= { userTableEntry 3 }
|
|
|
|
userEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable / Disable the selected user"
|
|
::= { userTableEntry 4 }
|
|
|
|
userPassword OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..67))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"User password, which must be entered in order to gain
|
|
access to the system."
|
|
::= { userTableEntry 5 }
|
|
|
|
-- SyslogControl group attribute definitions
|
|
--
|
|
syslogClient OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable the syslog client"
|
|
::= { syslogControl 1 }
|
|
|
|
syslogState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The syslog service has been enabled or disabled"
|
|
::= { syslogControl 2 }
|
|
|
|
-- RouterProtocols group attribute definitions
|
|
--
|
|
microwaveAdaptiveBandwidth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable support of Microwave Adaptive Bandwidth Protocol.
|
|
MAB is disabled if link symmetry is configured as
|
|
Adaptive"
|
|
::= { routerProtocols 1 }
|
|
|
|
mABNominalModulationMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modAcquisition(0),
|
|
modBpsk63percent(1),
|
|
modQpsk63percentSingle(2),
|
|
modTransient1(3),
|
|
modQpsk87percentSingle(4),
|
|
modTransient2(5),
|
|
mod16qam63percentSingleA(6),
|
|
modTransient3(7),
|
|
mod16qam87percentSingle(8),
|
|
modTransient4(9),
|
|
mod64qam75percentSingle(10),
|
|
modTransient5(11),
|
|
mod64qam92percentSingle(12),
|
|
modTransient6(13),
|
|
mod256qam81percentSingle(14),
|
|
mod16qam63percentSingleB(15),
|
|
mod16qam63percentDual(16),
|
|
modTransient7(17),
|
|
mod16qam87percentDual(18),
|
|
modTransient8(19),
|
|
mod64qam75percentDual(20),
|
|
modTransient9(21),
|
|
mod64qam92percentDual(22),
|
|
modTransient10(23),
|
|
mod256qam81percentDual(24)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Nominal modulation mode is the desired modulation
|
|
mode. MAB VSM packets are generated when the current
|
|
modulation mode falls below the nominal modulation."
|
|
::= { routerProtocols 2 }
|
|
|
|
mABTransmissionInterval OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
transmissionInterval1s(0),
|
|
transmissionInterval10s(1),
|
|
transmissionInterval60s(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The minimum interval (in seconds) between successive MAB
|
|
vendor specific messages (VSM). These VSM are sent when
|
|
the current transmit capacity falls below the configured
|
|
MAB Nominal Modulation Mode."
|
|
::= { routerProtocols 3 }
|
|
|
|
mABHoldoffPeriod OBJECT-TYPE
|
|
SYNTAX INTEGER (10..60)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The period (in seconds) over which transmit capacity is
|
|
averaged over to determine when the wireless link has
|
|
degraded"
|
|
::= { routerProtocols 4 }
|
|
|
|
mABMaintenanceLevel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maintenance Levels (0-7) determines the destination MAC
|
|
address of MAB vendor specific messages."
|
|
::= { routerProtocols 5 }
|
|
|
|
useVLANForMABProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noVLANTagging(0),
|
|
iEEE8021QTaggedCTagType8100(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This controls whether MAB vendor specific messages (VSM)
|
|
packets use VLAN tags or not."
|
|
::= { routerProtocols 6 }
|
|
|
|
mABProtocolVID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4094)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This VLAN VID (0-4094) will be included in MAB vendor
|
|
specific messages (VSM) packets."
|
|
::= { routerProtocols 7 }
|
|
|
|
mABProtocolVLANPriority OBJECT-TYPE
|
|
SYNTAX INTEGER (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This VLAN Priority (0-7) will be included in MAB vendor
|
|
specific messages (VSM) packets."
|
|
::= { routerProtocols 8 }
|
|
|
|
mABState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
degraded(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current state of MAB Protocol. A state of 'Normal' on a
|
|
green background indicates that a PTP link is operating
|
|
at nominal capacity"
|
|
::= { routerProtocols 9 }
|
|
|
|
mABNominalTransmitCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The nominal Tx capacity used in MAB Vendor Specific
|
|
Messages for the selected nominal modulation mode "
|
|
::= { routerProtocols 10 }
|
|
|
|
mABCurrentTransmitCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1000)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current Tx capacity of the wireless link used in the
|
|
last MAB Vendor Specific Message transmitted."
|
|
::= { routerProtocols 11 }
|
|
|
|
-- CableDiagnostics group attribute definitions
|
|
--
|
|
cableDiagnosticsPorts OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
auxPort(6),
|
|
mainPSUPort(7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Select ports on which Cable Diagnostics must be
|
|
executed"
|
|
::= { cableDiagnostics 1 }
|
|
|
|
cableDiagnosticsControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
startTest(0),
|
|
testInProgress(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set this attribute to 'Test in Progress' to start a
|
|
Cable Diagnostics test"
|
|
::= { cableDiagnostics 2 }
|
|
|
|
cableDiagnosticsWarning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle(0),
|
|
testInProgress(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Normal Ethernet operation is disrupted when a Cable
|
|
Diagnostics test is in progress"
|
|
::= { cableDiagnostics 3 }
|
|
|
|
cableDiagnosticsResultTableNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of rows in the Cable Diagnostics Result Table."
|
|
::= { cableDiagnostics 4 }
|
|
|
|
-- CableDiagnosticsResultTable group attribute definitions
|
|
--
|
|
cableDiagnosticsResultTableIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cable Diagnostics Port value used to index into the
|
|
result table."
|
|
::= { cableDiagnosticsResultTableEntry 1 }
|
|
|
|
cableDiagnosticsResultsDateTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Date and Time when a Cable Diagnostics test was last
|
|
executed"
|
|
::= { cableDiagnosticsResultTableEntry 2 }
|
|
|
|
cableDiagPair1Results OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
unknown(1),
|
|
inProgress(2),
|
|
notTested(3),
|
|
openCircuit(4),
|
|
shortCircuit(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the most recent execution of Cable
|
|
Diagnostics on cable pair 1. According to the T658B
|
|
wiring scheme, pair 1 is pins 4 & 5 on the RJ45 socket on
|
|
the ODU. Open Circuit is reported when the impedance is
|
|
greater than 330 ohms. Short Circuit is reported when the
|
|
impedance is less than 33 ohms. Unknown is reported when
|
|
a continuous signal is received from the link partner for
|
|
125 ms, preventing start of the test."
|
|
::= { cableDiagnosticsResultTableEntry 3 }
|
|
|
|
cableDiagPair1Distance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distance in meters from the ODU to the fault
|
|
detected on the cable pair during the most recent
|
|
execution of Cable Diagnostics. Faults in cables longer
|
|
than 160 meters (525 feet) may not be detected. The error
|
|
margin is +/-2 meters (6.5 feet)."
|
|
::= { cableDiagnosticsResultTableEntry 4 }
|
|
|
|
cableDiagPair2Results OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
unknown(1),
|
|
inProgress(2),
|
|
notTested(3),
|
|
openCircuit(4),
|
|
shortCircuit(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the most recent execution of Cable
|
|
Diagnostics on cable pair 2. According to the T658B
|
|
wiring scheme, pair 2 is pins 1 & 2 on the RJ45 socket on
|
|
the ODU. Open Circuit is reported when the impedance is
|
|
greater than 330 ohms. Short Circuit is reported when the
|
|
impedance is less than 33 ohms. Unknown is reported when
|
|
a continuous signal is received from the link partner for
|
|
125 ms, preventing start of the test."
|
|
::= { cableDiagnosticsResultTableEntry 5 }
|
|
|
|
cableDiagPair2Distance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distance in meters from the ODU to the fault
|
|
detected on the cable pair during the most recent
|
|
execution of Cable Diagnostics. Faults in cables longer
|
|
than 160 meters (525 feet) may not be detected. The error
|
|
margin is +/-2 meters (6.5 feet)."
|
|
::= { cableDiagnosticsResultTableEntry 6 }
|
|
|
|
cableDiagPair3Results OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
unknown(1),
|
|
inProgress(2),
|
|
notTested(3),
|
|
openCircuit(4),
|
|
shortCircuit(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the most recent execution of Cable
|
|
Diagnostics on cable pair 3. According to the T658B
|
|
wiring scheme, pair 3 is pins 3 & 6 on the RJ45 socket on
|
|
the ODU. Open Circuit is reported when the impedance is
|
|
greater than 330 ohms. Short Circuit is reported when the
|
|
impedance is less than 33 ohms. Unknown is reported when
|
|
a continuous signal is received from the link partner for
|
|
125 ms, preventing start of the test."
|
|
::= { cableDiagnosticsResultTableEntry 7 }
|
|
|
|
cableDiagPair3Distance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distance in meters from the ODU to the fault
|
|
detected on the cable pair during the most recent
|
|
execution of Cable Diagnostics. Faults in cables longer
|
|
than 160 meters (525 feet) may not be detected. The error
|
|
margin is +/-2 meters (6.5 feet)."
|
|
::= { cableDiagnosticsResultTableEntry 8 }
|
|
|
|
cableDiagPair4Results OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok(0),
|
|
unknown(1),
|
|
inProgress(2),
|
|
notTested(3),
|
|
openCircuit(4),
|
|
shortCircuit(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The result of the most recent execution of Cable
|
|
Diagnostics on cable pair 4. According to the T658B
|
|
wiring scheme, pair 4 is pins 7 & 8 on the RJ45 socket on
|
|
the ODU. Open Circuit is reported when the impedance is
|
|
greater than 330 ohms. Short Circuit is reported when the
|
|
impedance is less than 33 ohms. Unknown is reported when
|
|
a continuous signal is received from the link partner for
|
|
125 ms, preventing start of the test."
|
|
::= { cableDiagnosticsResultTableEntry 9 }
|
|
|
|
cableDiagPair4Distance OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distance in meters from the ODU to the fault
|
|
detected on the cable pair during the most recent
|
|
execution of Cable Diagnostics. Faults in cables longer
|
|
than 160 meters (525 feet) may not be detected. The error
|
|
margin is +/-2 meters (6.5 feet)."
|
|
::= { cableDiagnosticsResultTableEntry 10 }
|
|
|
|
-- Supplementary group attribute definitions
|
|
--
|
|
longitude OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..19))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The longitude of the unit, measured in decimal degrees.
|
|
This object is set by the SNMP manager and has no
|
|
internal function."
|
|
::= { supplementary 1 }
|
|
|
|
latitude OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..19))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The latitude of the unit, measured in decimal degrees.
|
|
This object is set by the SNMP manager and has no
|
|
internal function."
|
|
::= { supplementary 2 }
|
|
|
|
altitude OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The altitude of the unit, measured in meters. This
|
|
object is set by the SNMP manager and has no internal
|
|
function."
|
|
::= { supplementary 3 }
|
|
|
|
-- Enterprise NOTIFICATION definitions
|
|
--
|
|
|
|
channelChangeTrap NOTIFICATION-TYPE
|
|
OBJECTS { receiveChannel }
|
|
STATUS current
|
|
DESCRIPTION "The PTP radio has changed wireless channel.
|
|
This has been caused by either
|
|
i) mandatory radar avoidance,
|
|
a DFS impulsive interference event will also be
|
|
detected,
|
|
or
|
|
ii) Dynamic Spectrum Optimization, (DSO)
|
|
DSO improves link performance by selecting the
|
|
most appropriate transmit and receive channels
|
|
with the lowest level of interference."
|
|
::= { ptpTrapPrefix 1 }
|
|
|
|
dfsImpulsiveInterferenceTrap NOTIFICATION-TYPE
|
|
OBJECTS { receiveChannel }
|
|
STATUS current
|
|
DESCRIPTION "DFS impulsive interference detected event"
|
|
::= { ptpTrapPrefix 2 }
|
|
|
|
mainPSUPortStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { mainPSUPortStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Main PSU Ethernet link. NB: a
|
|
change of state may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { ptpTrapPrefix 3 }
|
|
|
|
mainPSUPortDisabledWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS { mainPSUPortDisabledWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { ptpTrapPrefix 4 }
|
|
|
|
mainPSUPortConfigurationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { mainPSUPortConfigurationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch"
|
|
::= { ptpTrapPrefix 5 }
|
|
|
|
auxPortStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { auxPortStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Aux Ethernet link. NB: a change of
|
|
state may generate an SNMP trap and/or SMTP email alert"
|
|
::= { ptpTrapPrefix 6 }
|
|
|
|
auxPortDisabledWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS { auxPortDisabledWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { ptpTrapPrefix 7 }
|
|
|
|
regulatoryBandTrap NOTIFICATION-TYPE
|
|
OBJECTS { regulatoryBand }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Regulatory Band prohibits the wireless unit from
|
|
operating outside the regulated limits. An invalid
|
|
Regulatory Band may be caused by a missing or incorrect
|
|
License Key, a corrupt MAC Address or an attempt to
|
|
configure a Regulatory Band not allowed by the License
|
|
Key. NB: a change of state may generate an SNMP trap
|
|
and/or SMTP email alert."
|
|
::= { ptpTrapPrefix 8 }
|
|
|
|
installStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { installStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-zero value indicates that signalling was received
|
|
with the wrong MAC address or a mismatched link name. NB:
|
|
It is very unusual to detect this, because units with
|
|
mis-configured Target MAC Address will normally fail to
|
|
establish a wireless link. However, rare circumstances
|
|
may establish a partial wireless link and detect this
|
|
situation. NB: A non-zero value on start-up, or a change
|
|
of value during operation, may generate an SNMP trap
|
|
and/or SMTP email alert"
|
|
::= { ptpTrapPrefix 9 }
|
|
|
|
installArmStateTrap NOTIFICATION-TYPE
|
|
OBJECTS { installArmState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the unit is being installed. NB: a change
|
|
of state may generate an SNMP trap and/or SMTP email
|
|
alert"
|
|
::= { ptpTrapPrefix 10 }
|
|
|
|
unitOutOfCalibrationTrap NOTIFICATION-TYPE
|
|
OBJECTS { unitOutOfCalibration }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unit is out of calibration"
|
|
::= { ptpTrapPrefix 11 }
|
|
|
|
auxPortPowerOverEthernetOutputStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { auxPortPowerOverEthernetOutputStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the Power Over Ethernet (PoE) output
|
|
of the Aux port"
|
|
::= { ptpTrapPrefix 12 }
|
|
|
|
incompatibleRegulatoryBandsTrap NOTIFICATION-TYPE
|
|
OBJECTS { incompatibleRegulatoryBands }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The master and slave units have incompatible regulatory
|
|
bands. NB: Both units must have compatible license keys"
|
|
::= { ptpTrapPrefix 14 }
|
|
|
|
noWirelessChannelAvailableTrap NOTIFICATION-TYPE
|
|
OBJECTS { noWirelessChannelAvailable }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Spectrum Management was unable to locate a suitable
|
|
wireless channel to operate on"
|
|
::= { ptpTrapPrefix 15 }
|
|
|
|
wirelessLinkDisabledWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS { wirelessLinkDisabledWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the wireless interface has
|
|
disabled wireless traffic"
|
|
::= { ptpTrapPrefix 16 }
|
|
|
|
auxPortConfigurationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { auxPortConfigurationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch. This
|
|
alarm is only raised if an Out-of-Band Management Mode
|
|
has been configured."
|
|
::= { ptpTrapPrefix 17 }
|
|
|
|
sFPErrorTrap NOTIFICATION-TYPE
|
|
OBJECTS { sFPError }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the SFP link is not OK, there are five possible
|
|
causes: Either a SFP has been installed but the license
|
|
key does not include SFP fiber support, a fiber link
|
|
could not be established even though no LOS was detected
|
|
(i.e. an optical carrier was detected, which could be due
|
|
to a broken TX fiber, or because the link is disabled at
|
|
the fiber link partner), a fiber link could not be
|
|
established and LOS is detected (i.e. no optical carrier
|
|
is detected), the installed SFP is not supported or the
|
|
installed SFP failed to initialize correctly. NB: a
|
|
change of status may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { ptpTrapPrefix 18 }
|
|
|
|
sFPPortStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { sFPPortStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the SFP Ethernet link. NB: a change of
|
|
state may generate an SNMP trap and/or SMTP email alert"
|
|
::= { ptpTrapPrefix 19 }
|
|
|
|
incompatibleMasterAndSlaveTrap NOTIFICATION-TYPE
|
|
OBJECTS { incompatibleMasterAndSlave }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A non-zero value indicates that the master and slave
|
|
ends of a link are different hardware products, or have
|
|
different software versions. NB: It is very unusual to
|
|
detect this, because incompatible units will normally
|
|
fail to establish a wireless link. However, some
|
|
combinations may establish a partial wireless link and
|
|
detect this situation. NB: A non-zero value may generate
|
|
an SNMP trap and/or SMTP email alert"
|
|
::= { ptpTrapPrefix 20 }
|
|
|
|
sNTPSyncTrap NOTIFICATION-TYPE
|
|
OBJECTS { sNTPSync }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If SNTP Sync fails then check the server settings in the
|
|
Remote Management page, or disable SNTP"
|
|
::= { ptpTrapPrefix 21 }
|
|
|
|
tDDSynchronizationAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { tDDSynchronizationAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Not Synchronized indicates failure of the external
|
|
timing system for a period greater than the holdover
|
|
timer. TDD frame timing will have drifted, and this link
|
|
may cause interference with other links in a synchronized
|
|
network. Timing System Failure is an early warning,
|
|
indicating that 80% of the holdover period has expired."
|
|
::= { ptpTrapPrefix 22 }
|
|
|
|
sFPPortDisabledWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS { sFPPortDisabledWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { ptpTrapPrefix 23 }
|
|
|
|
sFPPortConfigurationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { sFPPortConfigurationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch. This
|
|
alarm is only raised if an Out-of-Band Management Mode
|
|
has been configured."
|
|
::= { ptpTrapPrefix 24 }
|
|
|
|
linkModeOptimizationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { linkModeOptimizationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote node of this link has been configured with a
|
|
different link mode optimization"
|
|
::= { ptpTrapPrefix 25 }
|
|
|
|
tDMInterfaceStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { tDMInterfaceStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"@Current status of the connection to the TDM Box. A
|
|
state of 'Up' on a green background indicates that the
|
|
TDM Box is connected OK. When connecting a TDM Box only
|
|
the Main Ethernet port should be used"
|
|
::= { ptpTrapPrefix 26 }
|
|
|
|
tDMChannelStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { tDMChannelStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the TDM channels. A value of 0
|
|
indicates that a TDM channel is established"
|
|
::= { ptpTrapPrefix 27 }
|
|
|
|
tDMChannelLoopbackTrap NOTIFICATION-TYPE
|
|
OBJECTS { tDMChannelLoopback }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The loopback status of TDM channels. This is intended
|
|
for installation testing and should be set to 'None' for
|
|
normal operation. The wire connections to a unit can be
|
|
tested by applying a 'Copper' loopback to the local unit.
|
|
The wireless connection to the remote unit can be tested
|
|
by applying a 'Wireless' loopback to the remote unit with
|
|
no loopback on the local unit. NB: a change of state may
|
|
generate an SNMP trap and/or SMTP email alert"
|
|
::= { ptpTrapPrefix 28 }
|
|
|
|
nIDULanPortStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { nIDULanPortStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the NIDU LAN Ethernet link. NB: a
|
|
change of state may generate an SNMP trap and/or SMTP
|
|
email alert"
|
|
::= { ptpTrapPrefix 29 }
|
|
|
|
syslogStateTrap NOTIFICATION-TYPE
|
|
OBJECTS { syslogState }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The syslog service has been enabled or disabled"
|
|
::= { ptpTrapPrefix 30 }
|
|
|
|
syslogLocalNearlyFullTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "The syslog local log is nearly full (90%)"
|
|
::= { ptpTrapPrefix 31 }
|
|
|
|
syslogLocalWrappedTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "The syslog local log has wrapped"
|
|
::= { ptpTrapPrefix 32 }
|
|
|
|
syslogClientTrap NOTIFICATION-TYPE
|
|
OBJECTS { syslogClient }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or disable the syslog client"
|
|
::= { ptpTrapPrefix 33 }
|
|
|
|
secureModeAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { secureModeAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The secure mode (e.g. FIPS, UC-APL) state of the unit.
|
|
The secure mode is not configured(1) state indicates that
|
|
the unit is capable of secure mode operation, and one or
|
|
more of the following security materials has not been
|
|
configured: Key Of Keys, Private Key, Public Certificate,
|
|
DRNG Entropy Status, Wireless Encryption Key. The secure
|
|
mode mode is configured but not active(2) state indicates
|
|
that the unit is capable of secure mode operation, and
|
|
the security material has been configured, but the
|
|
configuration of interfaces is not consistent with secure
|
|
mode operation. The secure mode is not supported(3) state
|
|
indicates that the unit is not capable of secure mode
|
|
operation. The secure mode capability requires
|
|
appropriate hardware compatibility, license key and
|
|
software image."
|
|
::= { ptpTrapPrefix 34 }
|
|
|
|
dataBridgingStatusAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { dataBridgingStatusAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet Data traffic bridging is disabled because the
|
|
wireless link is not operating at the configured Lowest
|
|
Data Modulation Mode"
|
|
::= { ptpTrapPrefix 35 }
|
|
|
|
licenseRemainingTrialPeriodAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { licenseRemainingTrialPeriodAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If the full capability trial license period is about to
|
|
expire then purchase a license upgrade from your
|
|
reseller."
|
|
::= { ptpTrapPrefix 36 }
|
|
|
|
capacityVariantMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { capacityVariantMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote node of this link has a lower link capacity.
|
|
Operating with a reduced effective link capacity."
|
|
::= { ptpTrapPrefix 37 }
|
|
|
|
maxLinkRangeExceededTrap NOTIFICATION-TYPE
|
|
OBJECTS { maxLinkRangeExceeded }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured link range is greater than the maximum
|
|
allowed by the license key. The link will operate at a
|
|
reduced capacity while this condition applies. This alarm
|
|
is only raised if the license specifies a maximum link
|
|
range and the trial license is not active."
|
|
::= { ptpTrapPrefix 38 }
|
|
|
|
tDMConfigurationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { tDMConfigurationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current status of the configuration of the TDM Box. A
|
|
state of 'Ok' on a green background indicates that the
|
|
TDM Box configuration is matched OK with the remote end."
|
|
::= { ptpTrapPrefix 39 }
|
|
|
|
nIDULanPortDisabledWarningTrap NOTIFICATION-TYPE
|
|
OBJECTS { nIDULanPortDisabledWarning }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP ifAdminStatus of the interface has disabled
|
|
Ethernet traffic"
|
|
::= { ptpTrapPrefix 40 }
|
|
|
|
nIDULanPortConfigurationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { nIDULanPortConfigurationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detection of Ethernet fragments (runt packets) when
|
|
the link is in full duplex is an indication of an
|
|
auto-negotiation or forced configuration mismatch."
|
|
::= { ptpTrapPrefix 41 }
|
|
|
|
secondDataBridgingStatusAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { secondDataBridgingStatusAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bridging of Ethernet traffic from Second Data Service
|
|
has been disabled because the wireless link is not
|
|
operating at the configured Lowest Second Data Modulation
|
|
Mode"
|
|
::= { ptpTrapPrefix 42 }
|
|
|
|
transparentClockSourcePortAlarmTrap NOTIFICATION-TYPE
|
|
OBJECTS { transparentClockSourcePortAlarm }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transparent Clock will not function properly because
|
|
SFP, the selected clock source port is not FIBER"
|
|
::= { ptpTrapPrefix 43 }
|
|
|
|
portAllocationMismatchTrap NOTIFICATION-TYPE
|
|
OBJECTS { portAllocationMismatch }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The local and remote ODUs have different services
|
|
configured."
|
|
::= { ptpTrapPrefix 44 }
|
|
|
|
END
|