- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
3134 lines
121 KiB
Text
3134 lines
121 KiB
Text
--------------------------------------------------------------------------------
|
|
-- Avocent PM MIB
|
|
-- Copyright 2010 Avocent Corporation
|
|
-- Revision: 2.0.1
|
|
-- Last Modified: Nov 24, 2010
|
|
--------------------------------------------------------------------------------
|
|
|
|
PM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises, OBJECT-TYPE, MODULE-IDENTITY, Integer32
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex, InterfaceIndexOrZero
|
|
FROM IF-MIB;
|
|
|
|
--------------------------------------------------------------------------------
|
|
-- Object Groupings
|
|
--------------------------------------------------------------------------------
|
|
|
|
--@ Note: every product type should be uniquely identified underneath the
|
|
--@ Products object group. Each product should report its unique Products
|
|
--@ OBJECT IDENTIFIER in mib-2.system.sysObjectID. Please see the file
|
|
--@ "_Avocent Enterprise Object Identifier Assignment.txt" for a list of the
|
|
--@ IDs that have been assigned.
|
|
|
|
-- enterprises .1.3.6.1.4.1
|
|
|
|
-- avocent OBJECT IDENTIFIER ::= { enterprises 10418 }
|
|
|
|
pm MODULE-IDENTITY
|
|
LAST-UPDATED "201011240000Z"
|
|
ORGANIZATION "Avocent Corporation"
|
|
CONTACT-INFO "postal : Avocent Corporation
|
|
47281 Bayside Parkway
|
|
Fremont, CA 94538, USA
|
|
e-mail : Technical Support
|
|
techsupport@avocent.com"
|
|
DESCRIPTION
|
|
"This module defines the Avocent MIB extensions to
|
|
PM-PDU products."
|
|
|
|
REVISION "201011240000Z"
|
|
DESCRIPTION "Adding Power Management OIDs.
|
|
Fixed SYNTAX of some OIDs.
|
|
Updating OIDs DESCRIPTION to include not applicable values."
|
|
|
|
REVISION "201009240000Z"
|
|
DESCRIPTION "Syntax fixed to pass validation level 3."
|
|
|
|
REVISION "201004140000Z"
|
|
DESCRIPTION "Obsoleting fixed index OIDs from PDU table.
|
|
Added measurent type and alarm in PDU table.
|
|
Added missing power factor reset in outlet table.
|
|
Added sensor type and digital status in sensors table."
|
|
|
|
REVISION "200905210000Z"
|
|
DESCRIPTION "New tables for power measurements"
|
|
::= { enterprises 10418 17 }
|
|
|
|
pmProducts OBJECT IDENTIFIER ::= { pm 1 }
|
|
pmManagement OBJECT IDENTIFIER ::= { pm 2 }
|
|
--
|
|
pm1024 OBJECT IDENTIFIER ::= { pmProducts 1 } -- 10418.17.1.1
|
|
pm2003 OBJECT IDENTIFIER ::= { pmProducts 2 } -- 10418.17.1.2
|
|
pm2006 OBJECT IDENTIFIER ::= { pmProducts 3 } -- 10418.17.1.3
|
|
pm2024 OBJECT IDENTIFIER ::= { pmProducts 4 }
|
|
pm3003 OBJECT IDENTIFIER ::= { pmProducts 5 }
|
|
pm3006 OBJECT IDENTIFIER ::= { pmProducts 6 }
|
|
pm3024 OBJECT IDENTIFIER ::= { pmProducts 7 }
|
|
pm1010 OBJECT IDENTIFIER ::= { pmProducts 8 }
|
|
pm2010 OBJECT IDENTIFIER ::= { pmProducts 9 }
|
|
pm3010 OBJECT IDENTIFIER ::= { pmProducts 10 }
|
|
pm1020 OBJECT IDENTIFIER ::= { pmProducts 11 }
|
|
pm2020 OBJECT IDENTIFIER ::= { pmProducts 12 }
|
|
pm3020 OBJECT IDENTIFIER ::= { pmProducts 13 }
|
|
|
|
pmAppliance OBJECT IDENTIFIER ::= { pmManagement 1 } -- 10418.17.2.1
|
|
pmSessions OBJECT IDENTIFIER ::= { pmManagement 2 } -- 10418.17.2.2
|
|
pmPowerMgmt OBJECT IDENTIFIER ::= { pmManagement 5 } -- 10418.17.2.5
|
|
|
|
--
|
|
-- Note that traps are defined in a separate trap MIB
|
|
--
|
|
pmTrapObject OBJECT IDENTIFIER ::= { pmManagement 6 } -- 10418.17.2.6
|
|
|
|
|
|
--
|
|
-- pmAppliance
|
|
-- OBJECT IDENTIFIER ::= { pmManagement 1 } 10418.17.2.1
|
|
--
|
|
pmHostName OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The appliance name"
|
|
::= { pmAppliance 1 }
|
|
|
|
pmProductModel OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..50) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The appliance product model"
|
|
::= { pmAppliance 2 }
|
|
|
|
pmPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The part number of this appliance as shown on the label
|
|
attached or imprinted on the appliance."
|
|
::= { pmAppliance 3 }
|
|
|
|
pmSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The serial number of this appliance as shown on the label
|
|
attached or imprinted on the appliance."
|
|
::= { pmAppliance 4 }
|
|
|
|
pmEIDNumber OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The electronic ID number (EID) of this appliance as shown on the label
|
|
attached or imprinted on the appliance."
|
|
::= { pmAppliance 5 }
|
|
|
|
pmBootcodeVersion OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the bootcode of this appliance."
|
|
::= { pmAppliance 6 }
|
|
|
|
pmFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The version of the firmware of this appliance."
|
|
::= { pmAppliance 7 }
|
|
|
|
pmReboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reboot(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of reboot(2) will reboot the appliance.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reboot(2) = when SET the appliance immediately reboots."
|
|
::= { pmAppliance 9 }
|
|
|
|
--
|
|
-- pmSessions
|
|
-- OBJECT IDENTIFIER ::= { pmManagement 2 } 10418.17.2.2
|
|
--
|
|
pmActiveSessionsNumberOfSession OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of active sessions."
|
|
::= { pmSessions 1 }
|
|
|
|
pmActiveSessionsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmActiveSessionsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the list of active sessions."
|
|
::= { pmSessions 2 }
|
|
|
|
pmActiveSessionsTableEntry OBJECT-TYPE
|
|
SYNTAX PmActiveSessionsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the active session"
|
|
INDEX { pmActiveSessionsTableIndex }
|
|
::= { pmActiveSessionsTable 1 }
|
|
|
|
PmActiveSessionsTableEntry ::= SEQUENCE {
|
|
pmActiveSessionsTableIndex InterfaceIndexOrZero,
|
|
pmActiveSessionsTableUser DisplayString, -- user name
|
|
pmActiveSessionsTableGroup DisplayString, -- group name
|
|
pmActiveSessionsTableType DisplayString, -- RO/RW-ssh,telnet or web
|
|
pmActiveSessionsTableConnection DisplayString, -- type + target name
|
|
pmActiveSessionsTableSessionTime DisplayString, -- time of session
|
|
pmActiveSessionsTableFrom DisplayString, -- source of the session
|
|
pmActiveSessionsTableKill INTEGER
|
|
}
|
|
|
|
pmActiveSessionsTableIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique index representing an entry in this table."
|
|
::= { pmActiveSessionsTableEntry 1 }
|
|
|
|
pmActiveSessionsTableUser OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the user that opens this session."
|
|
::= { pmActiveSessionsTableEntry 2 }
|
|
|
|
pmActiveSessionsTableGroup OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the group that the user belongs to."
|
|
::= { pmActiveSessionsTableEntry 3 }
|
|
|
|
pmActiveSessionsTableType OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The session type."
|
|
::= { pmActiveSessionsTableEntry 4 }
|
|
|
|
pmActiveSessionsTableConnection OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connection type."
|
|
::= { pmActiveSessionsTableEntry 5 }
|
|
|
|
pmActiveSessionsTableSessionTime OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time of the session"
|
|
::= { pmActiveSessionsTableEntry 6 }
|
|
|
|
pmActiveSessionsTableFrom OBJECT-TYPE
|
|
SYNTAX DisplayString ( SIZE (0..32) )
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source IP address of the session."
|
|
::= { pmActiveSessionsTableEntry 7 }
|
|
|
|
pmActiveSessionsTableKill OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
killSession(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of killSession(2) will kill the session.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
killSession(2)= when SET the appliance immediately kills the session."
|
|
::= { pmActiveSessionsTableEntry 8 }
|
|
|
|
|
|
--
|
|
-- pmPowerMgmt
|
|
-- OBJECT IDENTIFIER ::= { pmManagement 5 } 10418.17.2.5
|
|
--
|
|
pmPowerMgmtNumSerialPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of Serial Ports that has PDU connected on the appliance."
|
|
::= { pmPowerMgmt 1 }
|
|
|
|
pmPowerMgmtSerialTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtSerialTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about each serial port thas has PDU connect."
|
|
::= { pmPowerMgmt 2 }
|
|
|
|
pmPowerMgmtSerialTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtSerialTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Information about each serial port thas has PDU connect."
|
|
INDEX { pmPowerMgmtSerialTableIndex }
|
|
::= { pmPowerMgmtSerialTable 1 }
|
|
|
|
PmPowerMgmtSerialTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtSerialTableIndex InterfaceIndex,
|
|
pmPowerMgmtSerialTablePortNumber Integer32,
|
|
pmPowerMgmtSerialTableDeviceName DisplayString,
|
|
pmPowerMgmtSerialTableNumberPDUs Integer32,
|
|
pmPowerMgmtSerialTableBuzzer Integer32,
|
|
pmPowerMgmtSerialTableSyslog Integer32,
|
|
pmPowerMgmtSerialTableOverCurrent Integer32,
|
|
pmPowerMgmtSerialTableCycleInterval Integer32,
|
|
pmPowerMgmtSerialTablePollRate Integer32,
|
|
pmPowerMgmtSerialTablePassWord DisplayString,
|
|
pmPowerMgmtSerialTableSave INTEGER,
|
|
pmPowerMgmtSerialTableRestore INTEGER
|
|
}
|
|
|
|
pmPowerMgmtSerialTableIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the register."
|
|
::= { pmPowerMgmtSerialTableEntry 1 }
|
|
|
|
pmPowerMgmtSerialTablePortNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of the serial port when the PDU is connected."
|
|
::= { pmPowerMgmtSerialTableEntry 2 }
|
|
|
|
pmPowerMgmtSerialTableDeviceName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device name of this serial port."
|
|
::= { pmPowerMgmtSerialTableEntry 3 }
|
|
|
|
pmPowerMgmtSerialTableNumberPDUs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of units connected in this serial port."
|
|
::= { pmPowerMgmtSerialTableEntry 4 }
|
|
|
|
pmPowerMgmtSerialTableBuzzer OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set/get buzzer(s) on or off for the chain.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSerialTableEntry 10 }
|
|
|
|
pmPowerMgmtSerialTableSyslog OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set/get syslog on or off for the chain.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSerialTableEntry 11 }
|
|
|
|
pmPowerMgmtSerialTableOverCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set/get over current proctection on or off for the chain.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSerialTableEntry 12 }
|
|
|
|
pmPowerMgmtSerialTableCycleInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set/get cycle interval for the chain in whole seconds.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSerialTableEntry 13 }
|
|
|
|
pmPowerMgmtSerialTablePollRate OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set/get the poll rate for the chain in whole seconds.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSerialTableEntry 14 }
|
|
|
|
pmPowerMgmtSerialTablePassWord OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"set the global password for admin user"
|
|
::= { pmPowerMgmtSerialTableEntry 15 }
|
|
|
|
pmPowerMgmtSerialTableSave OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
save(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
save(2) = when SET the save command is sent to PDU."
|
|
::= { pmPowerMgmtSerialTableEntry 20 }
|
|
|
|
pmPowerMgmtSerialTableRestore OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
restore(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
restore(2) = when SET the restore command is sent to PDU."
|
|
::= { pmPowerMgmtSerialTableEntry 21 }
|
|
|
|
pmPowerMgmtPDUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtPDUTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the list of detected PDUs."
|
|
::= { pmPowerMgmt 3 }
|
|
|
|
pmPowerMgmtPDUTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtPDUTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the PDU."
|
|
INDEX { pmPowerMgmtPDUTablePortNumber, pmPowerMgmtPDUTablePduIndex }
|
|
::= { pmPowerMgmtPDUTable 1 }
|
|
|
|
PmPowerMgmtPDUTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtPDUTablePortNumber InterfaceIndex, -- number of serial port
|
|
pmPowerMgmtPDUTablePduIndex InterfaceIndexOrZero,
|
|
pmPowerMgmtPDUTablePduId DisplayString, -- PDU identification
|
|
pmPowerMgmtPDUTablePortName DisplayString, -- Serial Port Name
|
|
pmPowerMgmtPDUTableModel DisplayString, -- PDU model
|
|
pmPowerMgmtPDUTableVendor DisplayString, -- Vendor
|
|
pmPowerMgmtPDUTableFirmwareVersion DisplayString, -- Firmware Version
|
|
pmPowerMgmtPDUTableNumberOfOutlets Integer32,
|
|
pmPowerMgmtPDUTableCurrentNOS Integer32, -- OBSOLETED number of current sensors
|
|
pmPowerMgmtPDUTableCurrent1Value Integer32, -- OBSOLETED actual value for current of the sensor 1
|
|
pmPowerMgmtPDUTableCurrent1Max Integer32, -- OBSOLETED max value for current of the sensor 1
|
|
pmPowerMgmtPDUTableCurrent2Value Integer32, -- OBSOLETED actual value for current of the sensor 2
|
|
pmPowerMgmtPDUTableCurrent2Max Integer32, -- OBSOLETED max value for current of the sensor 2
|
|
pmPowerMgmtPDUTableCurrent3Value Integer32, -- OBSOLETED actual value for current of the sensor 3
|
|
pmPowerMgmtPDUTableCurrent3Max Integer32, -- OBSOLETED max value for current of the sensor 3
|
|
pmPowerMgmtPDUTableTemperatureNOS Integer32, -- OBSOLETED number of temperature sensors
|
|
pmPowerMgmtPDUTableTemperature1Value Integer32, -- OBSOLETED actual value for Temperature 1
|
|
pmPowerMgmtPDUTableTemperature1Max Integer32, -- OBSOLETED max value for Temperature 1
|
|
pmPowerMgmtPDUTableTemperature2Value Integer32, -- OBSOLETED actual value for Temperaturet 2
|
|
pmPowerMgmtPDUTableTemperature2Max Integer32, -- OBSOLETED max value for Temperature 2
|
|
pmPowerMgmtPDUTableTemperature3Value Integer32, -- OBSOLETED actual value for Temperature 3
|
|
pmPowerMgmtPDUTableTemperature3Max Integer32, -- OBSOLETED max value for Temperature 3
|
|
pmPowerMgmtPDUTableHumidityNOS Integer32, -- OBSOLETED humidity number of humidity sensors
|
|
pmPowerMgmtPDUTableHumidity1Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 1
|
|
pmPowerMgmtPDUTableHumidity1Max Integer32, -- OBSOLETED max value for Humidityof the sensor 1
|
|
pmPowerMgmtPDUTableHumidity2Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 2
|
|
pmPowerMgmtPDUTableHumidity2Max Integer32, -- OBSOLETED max value for Humidity of the sensor 2
|
|
pmPowerMgmtPDUTableHumidity3Value Integer32, -- OBSOLETED actual value for Humidity of the sensor 3
|
|
pmPowerMgmtPDUTableHumidity3Max Integer32, -- OBSOLETED max value for Humidity of the sensor 3
|
|
pmPowerMgmtPDUTableVoltageNOS Integer32, -- OBSOLETED number of voltage sensor
|
|
pmPowerMgmtPDUTableVoltage1Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 1
|
|
pmPowerMgmtPDUTableVoltage1Max Integer32, -- OBSOLETED max value for Voltage of the sensor 1
|
|
pmPowerMgmtPDUTableVoltage2Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 2
|
|
pmPowerMgmtPDUTableVoltage2Max Integer32, -- OBSOLETED max value for Voltaget of the sensor 2
|
|
pmPowerMgmtPDUTableVoltage3Value Integer32, -- OBSOLETED actual value for Voltage of the sensor 3
|
|
pmPowerMgmtPDUTableVoltage3Max Integer32, -- OBSOLETED max value for Voltage of the sensor 3
|
|
pmPowerMgmtPDUTableNumberOfPhases Integer32, -- number of phases (0 if single phase)
|
|
pmPowerMgmtPDUTableNumberOfBanks Integer32, -- number of banks
|
|
pmPowerMgmtPDUTableNumberOfSensors Integer32, -- number of sensors
|
|
pmPowerMgmtPDUTableFactoryDefault INTEGER, -- set PDU to factory default settings
|
|
pmPowerMgmtPDUTableColdStartDelay Integer32, -- get/set PDUs cold start delay
|
|
pmPowerMgmtPDUTableReboot INTEGER, -- reboot the PDU
|
|
pmPowerMgmtPDUTableMaxCurrent Integer32, -- max value allowed for current
|
|
pmPowerMgmtPDUTableAlarm INTEGER, -- PDU alarm status
|
|
pmPowerMgmtPDUTableCurrentValue Integer32, -- actual value for current of the sensor
|
|
pmPowerMgmtPDUTableCurrentMax Integer32, -- max value for current
|
|
pmPowerMgmtPDUTableCurrentMin Integer32, -- min value for current
|
|
pmPowerMgmtPDUTableCurrentAvg Integer32, -- average value for current
|
|
pmPowerMgmtPDUTableCurrentReset INTEGER, -- reset the current stats
|
|
pmPowerMgmtPDUTablePowerValue Integer32, -- actual value for power
|
|
pmPowerMgmtPDUTablePowerMax Integer32, -- max value for power
|
|
pmPowerMgmtPDUTablePowerMin Integer32, -- min value for power
|
|
pmPowerMgmtPDUTablePowerAvg Integer32, -- average value for power
|
|
pmPowerMgmtPDUTablePowerReset INTEGER, -- reset the power stats
|
|
pmPowerMgmtPDUTablePowerType INTEGER, -- type of power measurement
|
|
pmPowerMgmtPDUTableVoltageValue Integer32, -- actual value for voltage
|
|
pmPowerMgmtPDUTableVoltageMax Integer32, -- max value for voltage
|
|
pmPowerMgmtPDUTableVoltageMin Integer32, -- min value for voltage
|
|
pmPowerMgmtPDUTableVoltageAvg Integer32, -- average value for voltage
|
|
pmPowerMgmtPDUTableVoltageReset INTEGER, -- reset the voltage stats
|
|
pmPowerMgmtPDUTableVoltageType INTEGER, -- type of voltage measurement
|
|
pmPowerMgmtPDUTablePowerFactorValue Integer32, -- actual value for powerfactor
|
|
pmPowerMgmtPDUTablePowerFactorMax Integer32, -- max value for powerfactor
|
|
pmPowerMgmtPDUTablePowerFactorMin Integer32, -- min value for powerfactor
|
|
pmPowerMgmtPDUTablePowerFactorAvg Integer32, -- average value for powerfactor
|
|
pmPowerMgmtPDUTablePowerFactorReset INTEGER, -- reset the powerfactor stats
|
|
pmPowerMgmtPDUTablePowerFactorType INTEGER, -- type of power factor measurement
|
|
pmPowerMgmtPDUTablePowerControl INTEGER, -- manage the outlets in this PDU
|
|
pmPowerMgmtPDUTableResetOCP INTEGER, -- reset the ocp (pdu wide)
|
|
pmPowerMgmtPDUTableCurrentHighCritical Integer32, -- get/set current high critical threshold
|
|
pmPowerMgmtPDUTableCurrentHighWarning Integer32, -- get/set current high warning threshold
|
|
pmPowerMgmtPDUTableCurrentLowWarning Integer32, -- get/set current low warning threshold
|
|
pmPowerMgmtPDUTableCurrentLowCritical Integer32, -- get/set current low critical threshold
|
|
pmPowerMgmtPDUTableEnergyValue Integer32, -- Energy value
|
|
pmPowerMgmtPDUTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
|
|
pmPowerMgmtPDUTableEnergyReset INTEGER -- reset energy calculation and start time to now
|
|
}
|
|
|
|
pmPowerMgmtPDUTablePortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of serial port when the PDU is connected."
|
|
::= { pmPowerMgmtPDUTableEntry 1 }
|
|
|
|
pmPowerMgmtPDUTablePduIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A PDU position in the chain."
|
|
::= { pmPowerMgmtPDUTableEntry 2 }
|
|
|
|
pmPowerMgmtPDUTablePduId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU identification."
|
|
::= { pmPowerMgmtPDUTableEntry 3 }
|
|
|
|
pmPowerMgmtPDUTablePortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of serial port when the PDU is connected."
|
|
::= { pmPowerMgmtPDUTableEntry 4 }
|
|
|
|
pmPowerMgmtPDUTableModel OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Model of the PDU.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtPDUTableEntry 5 }
|
|
|
|
pmPowerMgmtPDUTableVendor OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Vendor of the PDU.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtPDUTableEntry 6 }
|
|
|
|
pmPowerMgmtPDUTableFirmwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Version of the PDU firmware.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtPDUTableEntry 7 }
|
|
|
|
pmPowerMgmtPDUTableNumberOfOutlets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of outlets of the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 8 }
|
|
|
|
pmPowerMgmtPDUTableCurrentNOS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of current sensors in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 9 }
|
|
|
|
pmPowerMgmtPDUTableCurrent1Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Current of the sensor 1 in this PDU unit in AMP.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.).
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentValue,
|
|
pmPowerMgmtPhasesTableCurrentValue, or
|
|
pmPowerMgmtOutletsTableCurrentValue"
|
|
::= { pmPowerMgmtPDUTableEntry 10 }
|
|
|
|
pmPowerMgmtPDUTableCurrent1Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum current of the sensor 1 in this PDU unit in AMP.
|
|
When the PDU does not have support for maximum value,
|
|
the value will be 0.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.)
|
|
Clear this value, set it with Zero value.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentMax,
|
|
pmPowerMgmtPhasesTableCurrentMax, or
|
|
pmPowerMgmtOutletsTableCurrentMax"
|
|
::= { pmPowerMgmtPDUTableEntry 11 }
|
|
|
|
pmPowerMgmtPDUTableCurrent2Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Current of the sensor 2 in this PDU unit in AMP.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.).
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentValue,
|
|
pmPowerMgmtPhasesTableCurrentValue, or
|
|
pmPowerMgmtOutletsTableCurrentValue"
|
|
::= { pmPowerMgmtPDUTableEntry 12 }
|
|
|
|
pmPowerMgmtPDUTableCurrent2Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum current of the sensor 2 in this PDU unit in AMP.
|
|
When the PDU does not have support for maximum value,
|
|
the value will be 0.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.)
|
|
Clear this value, set it with Zero value.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentMax,
|
|
pmPowerMgmtPhasesTableCurrentMax, or
|
|
pmPowerMgmtOutletsTableCurrentMax"
|
|
::= { pmPowerMgmtPDUTableEntry 13}
|
|
|
|
pmPowerMgmtPDUTableCurrent3Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Current of the sensor 3 in this PDU unit in AMP.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.)
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentValue,
|
|
pmPowerMgmtPhasesTableCurrentValue, or
|
|
pmPowerMgmtOutletsTableCurrentValue"
|
|
::= { pmPowerMgmtPDUTableEntry 14 }
|
|
|
|
pmPowerMgmtPDUTableCurrent3Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum current of the sensor 3 in this PDU unit in AMP.
|
|
When the PDU does not have support for maximum value,
|
|
the value will be 0.
|
|
The value of this object is the actual current in
|
|
AMP * 10. You need to translate the readed value
|
|
(Ex. : value is 5, the current is 0.5 AMP.)
|
|
Clear this value, set it with Zero value.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableCurrentMax,
|
|
pmPowerMgmtPhasesTableCurrentMax, or
|
|
pmPowerMgmtOutletsTableCurrentMax"
|
|
::= { pmPowerMgmtPDUTableEntry 15 }
|
|
|
|
pmPowerMgmtPDUTableTemperatureNOS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of temperature sensors in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 16 }
|
|
|
|
pmPowerMgmtPDUTableTemperature1Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Temperature of this PM unit in Celsius degrees.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
|
|
::= { pmPowerMgmtPDUTableEntry 17 }
|
|
|
|
pmPowerMgmtPDUTableTemperature1Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum temperature detected in this PM unit in Celsius degrees.
|
|
The value will be Zero when the PDU does not have support for maximum value.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 18 }
|
|
|
|
pmPowerMgmtPDUTableTemperature2Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Temperature of this PM unit in Celsius degrees.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
|
|
::= { pmPowerMgmtPDUTableEntry 19 }
|
|
|
|
pmPowerMgmtPDUTableTemperature2Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum temperature detected in this PM unit in Celsius degrees.
|
|
The value will be Zero when the PDU does not have support for maximum value.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 20 }
|
|
|
|
pmPowerMgmtPDUTableTemperature3Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Temperature of this PM unit in Celsius degrees.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius)."
|
|
::= { pmPowerMgmtPDUTableEntry 21 }
|
|
|
|
pmPowerMgmtPDUTableTemperature3Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum temperature detected in this PM unit in Celsius degrees.
|
|
The value will be Zero when the PDU does not have support for maximum value.
|
|
The value of this object is the actual temperature in
|
|
degrees C * 10. You need to translate the readed value
|
|
(Ex. : value is 240, the temperature is 24 Celsius.)
|
|
If the temperature measurement is not installed this
|
|
value will be 0.
|
|
Valid values are 5 to 999 ( 0.5 to 99.9 Celsius).
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 22 }
|
|
|
|
pmPowerMgmtPDUTableHumidityNOS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of humidity sensors in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 23 }
|
|
|
|
pmPowerMgmtPDUTableHumidity1Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Humidity of this PM unit .
|
|
If the humidity measurement is not installed this
|
|
value will be 0."
|
|
::= { pmPowerMgmtPDUTableEntry 24 }
|
|
|
|
pmPowerMgmtPDUTableHumidity1Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum humidity detected in this PM unit.
|
|
If the humidity measurement is not installed or the PDU does not have support for maximum value this
|
|
value will be 0.
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 25 }
|
|
|
|
pmPowerMgmtPDUTableHumidity2Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Humidity of this PM unit .
|
|
If the humidity measurement is not installed this
|
|
value will be 0."
|
|
::= { pmPowerMgmtPDUTableEntry 26 }
|
|
|
|
pmPowerMgmtPDUTableHumidity2Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum humidity detected in this PM unit.
|
|
If the humidity measurement is not installed or the PDU does not have support for maximum value this
|
|
value will be 0.
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 27 }
|
|
|
|
pmPowerMgmtPDUTableHumidity3Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Humidity of this PM unit .
|
|
If the humidity measurement is not installed this
|
|
value will be 0."
|
|
::= { pmPowerMgmtPDUTableEntry 28 }
|
|
|
|
pmPowerMgmtPDUTableHumidity3Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum humidity detected in this PM unit.
|
|
If the humidity measurement is not installed or the PDU does not have support for maximum value this
|
|
value will be 0.
|
|
Set with Zero value to clear the max. temperature."
|
|
::= { pmPowerMgmtPDUTableEntry 29 }
|
|
|
|
pmPowerMgmtPDUTableVoltageNOS OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of voltage sensors in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 30 }
|
|
|
|
pmPowerMgmtPDUTableVoltage1Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Voltage of this sensor in this PDU unit.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageValue,
|
|
pmPowerMgmtPhasesTableVoltageValue, or
|
|
pmPowerMgmtOutletsTableVoltageValue"
|
|
::= { pmPowerMgmtPDUTableEntry 31 }
|
|
|
|
pmPowerMgmtPDUTableVoltage1Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum voltage of this sensor in this PDU unit.
|
|
Set with Zero value to clear the maximum voltage.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageMax,
|
|
pmPowerMgmtPhasesTableVoltageMax, or
|
|
pmPowerMgmtOutletsTableVoltageMax"
|
|
::= { pmPowerMgmtPDUTableEntry 32 }
|
|
|
|
pmPowerMgmtPDUTableVoltage2Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Voltage of this sensor in this PDU unit.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageValue,
|
|
pmPowerMgmtPhasesTableVoltageValue, or
|
|
pmPowerMgmtOutletsTableVoltageValue"
|
|
::= { pmPowerMgmtPDUTableEntry 33 }
|
|
|
|
pmPowerMgmtPDUTableVoltage2Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum voltage of this sensor in this PDU unit.
|
|
Set with Zero value to clear the maximum voltage.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageMax,
|
|
pmPowerMgmtPhasesTableVoltageMax, or
|
|
pmPowerMgmtOutletsTableVoltageMax"
|
|
::= { pmPowerMgmtPDUTableEntry 34 }
|
|
|
|
pmPowerMgmtPDUTableVoltage3Value OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Voltage of this sensor in this PDU unit.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageValue,
|
|
pmPowerMgmtPhasesTableVoltageValue, or
|
|
pmPowerMgmtOutletsTableVoltageValue"
|
|
::= { pmPowerMgmtPDUTableEntry 35 }
|
|
|
|
pmPowerMgmtPDUTableVoltage3Max OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Maximum voltage of this sensor in this PDU unit.
|
|
Set with Zero value to clear the maximum voltage.
|
|
This OID is obsoleted. The value can be retrieved
|
|
from pmPowerMgmtPDUTableVoltageMax,
|
|
pmPowerMgmtPhasesTableVoltageMax, or
|
|
pmPowerMgmtOutletsTableVoltageMax"
|
|
::= { pmPowerMgmtPDUTableEntry 36 }
|
|
|
|
pmPowerMgmtPDUTableNumberOfPhases OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of phases of the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 37 }
|
|
|
|
pmPowerMgmtPDUTableNumberOfBanks OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of banks in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 38 }
|
|
|
|
pmPowerMgmtPDUTableNumberOfSensors OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of sensors in the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 40 }
|
|
|
|
pmPowerMgmtPDUTableFactoryDefault OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of 2 will set the PDU to factory default settings.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the factory default command is sent to the PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 41 }
|
|
|
|
pmPowerMgmtPDUTableColdStartDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDUs cold start delay in whole seconds (0-60).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 42 }
|
|
|
|
pmPowerMgmtPDUTableReboot OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reboot(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of power*(2) will send command to PDU.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reboot(2) = when SET the reboot command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 43 }
|
|
|
|
pmPowerMgmtPDUTableMaxCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of current allowed in the PDU (A x 10)."
|
|
::= { pmPowerMgmtPDUTableEntry 44 }
|
|
|
|
pmPowerMgmtPDUTableAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
blow-fuse (2),
|
|
hw-ocp (3),
|
|
high-critical (4),
|
|
high-warning (5),
|
|
low-warning (6),
|
|
low-critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the PDU alarm status.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 45 }
|
|
|
|
--@ Note: Intentionally left space for future expansion (thanks!)
|
|
pmPowerMgmtPDUTableCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of current in the PDU (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 50 }
|
|
|
|
pmPowerMgmtPDUTableCurrentMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of current in the PDU (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 51 }
|
|
|
|
pmPowerMgmtPDUTableCurrentMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of current in the PDU (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 52 }
|
|
|
|
pmPowerMgmtPDUTableCurrentAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of current in the PDU (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 53 }
|
|
|
|
pmPowerMgmtPDUTableCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 54 }
|
|
|
|
pmPowerMgmtPDUTablePowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power in the PDU (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 60 }
|
|
|
|
pmPowerMgmtPDUTablePowerMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power in the PDU (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 61 }
|
|
|
|
pmPowerMgmtPDUTablePowerMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power in the PDU (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 62 }
|
|
|
|
pmPowerMgmtPDUTablePowerAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power in the PDU (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 63 }
|
|
|
|
pmPowerMgmtPDUTablePowerReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 64 }
|
|
|
|
pmPowerMgmtPDUTablePowerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 65 }
|
|
|
|
pmPowerMgmtPDUTableVoltageValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of voltage in the PDU (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 70 }
|
|
|
|
pmPowerMgmtPDUTableVoltageMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of voltage in the PDU (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 71 }
|
|
|
|
pmPowerMgmtPDUTableVoltageMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of voltage in the PDU (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 72 }
|
|
|
|
pmPowerMgmtPDUTableVoltageAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of voltage in the PDU (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 73 }
|
|
|
|
pmPowerMgmtPDUTableVoltageReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 74 }
|
|
|
|
pmPowerMgmtPDUTableVoltageType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of voltage values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 75 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power factor in the PDU (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 80 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power factor in the PDU (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 81 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power factor in the PDU (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 82 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power factor in the PDU (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 83 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 84 }
|
|
|
|
pmPowerMgmtPDUTablePowerFactorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 85 }
|
|
|
|
pmPowerMgmtPDUTablePowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
powerOn(2),
|
|
powerOff(3),
|
|
powerCycle(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of power*(2-4) will send command to PDU.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
powerOn(2) = when SET the power On command is sent to PDU.
|
|
powerOff(3) = when SET the power Off command is sent to PDU.
|
|
powerCycle(4)=when SET the power cycle command is sent to PDU.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 90 }
|
|
|
|
pmPowerMgmtPDUTableResetOCP OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of power*(2) will send command to PDU.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 91 }
|
|
|
|
pmPowerMgmtPDUTableCurrentHighCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet high critical (alarm) current threshold (A x 10).
|
|
Set fails if value is lower that CurrentHighWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 100 }
|
|
|
|
pmPowerMgmtPDUTableCurrentHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet high warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 101 }
|
|
|
|
pmPowerMgmtPDUTableCurrentLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet low warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 102 }
|
|
|
|
pmPowerMgmtPDUTableCurrentLowCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet low critical current threshold (A x 10).
|
|
Set fails if value is higher than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 103 }
|
|
|
|
pmPowerMgmtPDUTableEnergyValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"pdu energy value (Wh).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPDUTableEntry 105 }
|
|
|
|
pmPowerMgmtPDUTableEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"time at which energy calculation commenced (ISO8601 format).
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtPDUTableEntry 106 }
|
|
|
|
pmPowerMgmtPDUTableEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPDUTableEntry 107 }
|
|
|
|
pmPowerMgmtTotalNumberOfOutlets OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of outlets managed by the appliance."
|
|
::= { pmPowerMgmt 4 }
|
|
|
|
pmPowerMgmtOutletsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtOutletsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about outlets."
|
|
::= { pmPowerMgmt 5 }
|
|
|
|
pmPowerMgmtOutletsTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtOutletsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the outlet."
|
|
INDEX { pmPowerMgmtOutletsTablePortNumber,
|
|
pmPowerMgmtOutletsTablePduNumber,
|
|
pmPowerMgmtOutletsTableNumber }
|
|
::= { pmPowerMgmtOutletsTable 1 }
|
|
|
|
PmPowerMgmtOutletsTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtOutletsTablePortNumber InterfaceIndex, -- serial port #
|
|
pmPowerMgmtOutletsTablePduNumber InterfaceIndex,
|
|
pmPowerMgmtOutletsTableNumber InterfaceIndex, -- outlet number in PDU
|
|
pmPowerMgmtOutletsTableName DisplayString, -- outlet name
|
|
pmPowerMgmtOutletsTableStatus INTEGER, -- outlet status
|
|
pmPowerMgmtOutletsTablePowerControl INTEGER, -- manage the outlet
|
|
pmPowerMgmtOutletsTablePortName DisplayString, -- serial port name
|
|
pmPowerMgmtOutletsTablePduId DisplayString, -- PDU ID
|
|
pmPowerMgmtOutletsTablePostOnDelay Integer32, -- outlet post on delay delay/post power on
|
|
pmPowerMgmtOutletsTablePostOffDelay Integer32, -- outlet post off delay/post power off
|
|
pmPowerMgmtOutletsTableAlarm INTEGER, -- outlet alarm status
|
|
pmPowerMgmtOutletsTableCurrentValue Integer32, -- actual value for current of the sensor
|
|
pmPowerMgmtOutletsTableCurrentMax Integer32, -- max value for current
|
|
pmPowerMgmtOutletsTableCurrentMin Integer32, -- min value for current
|
|
pmPowerMgmtOutletsTableCurrentAvg Integer32, -- average value for current
|
|
pmPowerMgmtOutletsTableCurrentReset INTEGER, -- reset the current stats
|
|
pmPowerMgmtOutletsTablePowerValue Integer32, -- actual value for power
|
|
pmPowerMgmtOutletsTablePowerMax Integer32, -- max value for power
|
|
pmPowerMgmtOutletsTablePowerMin Integer32, -- min value for power
|
|
pmPowerMgmtOutletsTablePowerAvg Integer32, -- average value for power
|
|
pmPowerMgmtOutletsTablePowerReset INTEGER, -- reset the power stats
|
|
pmPowerMgmtOutletsTablePowerType INTEGER, -- power type
|
|
pmPowerMgmtOutletsTableVoltageValue Integer32, -- actual value for voltage
|
|
pmPowerMgmtOutletsTableVoltageMax Integer32, -- max value for voltage
|
|
pmPowerMgmtOutletsTableVoltageMin Integer32, -- min value for voltage
|
|
pmPowerMgmtOutletsTableVoltageAvg Integer32, -- average value for voltage
|
|
pmPowerMgmtOutletsTableVoltageReset INTEGER, -- reset the voltage stats
|
|
pmPowerMgmtOutletsTableVoltageType INTEGER, -- type of voltage measurement
|
|
pmPowerMgmtOutletsTablePowerFactorValue Integer32, -- actual value for powerfactor
|
|
pmPowerMgmtOutletsTablePowerFactorMax Integer32, -- max value for powerfactor
|
|
pmPowerMgmtOutletsTablePowerFactorMin Integer32, -- min value for powerfactor
|
|
pmPowerMgmtOutletsTablePowerFactorAvg Integer32, -- average value for powerfactor
|
|
pmPowerMgmtOutletsTablePowerFactorReset INTEGER, -- reset the powerfactor stats
|
|
pmPowerMgmtOutletsTablePowerFactorType INTEGER, -- power factor type
|
|
pmPowerMgmtOutletsTableCurrentHighCritical Integer32, -- outlet current high critical threshold
|
|
pmPowerMgmtOutletsTableCurrentHighWarning Integer32, -- outlet current high warning threshold
|
|
pmPowerMgmtOutletsTableCurrentLowWarning Integer32, -- outlet current low warning threshold
|
|
pmPowerMgmtOutletsTableCurrentLowCritical Integer32, -- outlet current low critical threshold
|
|
pmPowerMgmtOutletsTableEnergyValue Integer32, -- Energy value
|
|
pmPowerMgmtOutletsTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
|
|
pmPowerMgmtOutletsTableEnergyReset INTEGER -- reset energy calculation and start time to now
|
|
}
|
|
|
|
pmPowerMgmtOutletsTablePortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port number."
|
|
::= { pmPowerMgmtOutletsTableEntry 1 }
|
|
|
|
pmPowerMgmtOutletsTablePduNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index."
|
|
::= { pmPowerMgmtOutletsTableEntry 2 }
|
|
|
|
pmPowerMgmtOutletsTableNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the outlet in the PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 3 }
|
|
|
|
pmPowerMgmtOutletsTableName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the outlet."
|
|
::= { pmPowerMgmtOutletsTableEntry 4 }
|
|
|
|
pmPowerMgmtOutletsTableStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2),
|
|
offLocked(3),
|
|
onLocked(4),
|
|
offCycle(5),
|
|
onPendingOff(6),
|
|
offPendingOn(7),
|
|
onPendingCycle(8),
|
|
notSet(9),
|
|
onFixed(10),
|
|
offShutdown(11),
|
|
tripped(12)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the outlet.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 5 }
|
|
|
|
pmPowerMgmtOutletsTablePowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
powerOn(2),
|
|
powerOff(3),
|
|
powerCycle(4),
|
|
powerLock(5),
|
|
powerUnlock(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of power*(2-6) will send command to PDU.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
powerOn(2) = when SET the power On command is sent to PDU.
|
|
powerOff(3) = when SET the power Off command is sent to PDU.
|
|
powerCycle(4)=when SET the power cycle command is sent to PDU.
|
|
powerLock(5)= when SET the power lock command is sent to PDU.
|
|
powerUnlock(6)=when SET the power unlock command is sent to PDU.
|
|
The powerLock and powerUnlock are valid only for Cyclades-PM PDUs"
|
|
::= { pmPowerMgmtOutletsTableEntry 6 }
|
|
|
|
pmPowerMgmtOutletsTablePortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port Name where the PDU is connected."
|
|
::= { pmPowerMgmtOutletsTableEntry 7 }
|
|
|
|
pmPowerMgmtOutletsTablePduId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU identification."
|
|
::= { pmPowerMgmtOutletsTableEntry 8 }
|
|
|
|
pmPowerMgmtOutletsTablePostOnDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"post on delay for the outlet (seconds x 10)
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 9 }
|
|
|
|
pmPowerMgmtOutletsTablePostOffDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"post off delay for the outlet (seconds x 10)
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 10 }
|
|
|
|
pmPowerMgmtOutletsTableAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
blow-fuse (2),
|
|
hw-ocp (3),
|
|
high-critical (4),
|
|
high-warning (5),
|
|
low-warning (6),
|
|
low-critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the outlet alarm status.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 45 }
|
|
|
|
--@ Note: Intentionally left space for future expansion
|
|
pmPowerMgmtOutletsTableCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of current in the outlet (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 50 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of current in the outlet (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 51 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of current in the outlet (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 52 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of current in the outlet (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 53 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 54 }
|
|
|
|
pmPowerMgmtOutletsTablePowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power in the outlet (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 60 }
|
|
|
|
pmPowerMgmtOutletsTablePowerMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power in the outlet (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 61 }
|
|
|
|
pmPowerMgmtOutletsTablePowerMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power in the outlet (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 62 }
|
|
|
|
pmPowerMgmtOutletsTablePowerAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power in the outlet (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 63 }
|
|
|
|
pmPowerMgmtOutletsTablePowerReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 64 }
|
|
|
|
pmPowerMgmtOutletsTablePowerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 65 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of voltage in the outlet (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 70 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of voltage in the outlet (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 71 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of voltage in the outlet (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 72 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of voltage in the outlet (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 73 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 74 }
|
|
|
|
pmPowerMgmtOutletsTableVoltageType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of voltage values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 75 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power factor in the outlet (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 80 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power factor in the outlet (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 81 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power factor in the outlet (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 82 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power factor in the outlet (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 83 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 84 }
|
|
|
|
pmPowerMgmtOutletsTablePowerFactorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power factor values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 85 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentHighCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet high critical (alarm) current threshold (A x 10).
|
|
Set fails if value is lower that CurrentHighWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 100 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet high warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 101 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet low warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 102 }
|
|
|
|
pmPowerMgmtOutletsTableCurrentLowCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet low critical current threshold (A x 10).
|
|
Set fails if value is higher than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 103 }
|
|
|
|
pmPowerMgmtOutletsTableEnergyValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"outlet energy value (Wh).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtOutletsTableEntry 105 }
|
|
|
|
pmPowerMgmtOutletsTableEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"time at which energy calculation commenced (ISO8601 format).
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtOutletsTableEntry 106 }
|
|
|
|
pmPowerMgmtOutletsTableEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtOutletsTableEntry 107 }
|
|
|
|
pmPowerMgmtNumberOfOutletGroup OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of configured group of outlets."
|
|
::= { pmPowerMgmt 6 }
|
|
|
|
pmPowerMgmtGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtGroupTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about group of outlets."
|
|
::= { pmPowerMgmt 7 }
|
|
|
|
pmPowerMgmtGroupTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtGroupTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about group of outlets."
|
|
INDEX { pmPowerMgmtGroupTableIndex }
|
|
::= { pmPowerMgmtGroupTable 1 }
|
|
|
|
PmPowerMgmtGroupTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtGroupTableIndex InterfaceIndexOrZero,
|
|
pmPowerMgmtGroupTableName DisplayString, -- group name
|
|
pmPowerMgmtGroupTableStatus INTEGER, -- group status
|
|
pmPowerMgmtGroupTablePowerControl INTEGER -- manage the group
|
|
}
|
|
|
|
pmPowerMgmtGroupTableIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index of the group."
|
|
::= { pmPowerMgmtGroupTableEntry 1 }
|
|
|
|
pmPowerMgmtGroupTableName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the group of outlets."
|
|
::= { pmPowerMgmtGroupTableEntry 2 }
|
|
|
|
pmPowerMgmtGroupTableStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of the group of outlet."
|
|
::= { pmPowerMgmtGroupTableEntry 3 }
|
|
|
|
pmPowerMgmtGroupTablePowerControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
powerOn(2),
|
|
powerOff(3),
|
|
powerCycle(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A set value of power*(2-4) will send command to PDU.
|
|
noAction(1) = always returned in a GET. Does nothing if SET.
|
|
powerOn(2) = when SET the power On command is sent to PDU.
|
|
powerOff(3) = when SET the power Off command is sent to PDU.
|
|
powerCycle(4)=when SET the power cycle command is sent to PDU."
|
|
::= { pmPowerMgmtGroupTableEntry 4 }
|
|
|
|
pmPowerMgmtTotalNumberOfPhases OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of phases managed by the appliance."
|
|
::= { pmPowerMgmt 8 }
|
|
|
|
pmPowerMgmtPhasesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtPhasesTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about phases."
|
|
::= { pmPowerMgmt 9 }
|
|
|
|
pmPowerMgmtPhasesTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtPhasesTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the phases."
|
|
INDEX { pmPowerMgmtPhasesTablePortNumber,
|
|
pmPowerMgmtPhasesTablePduNumber,
|
|
pmPowerMgmtPhasesTableNumber }
|
|
::= { pmPowerMgmtPhasesTable 1 }
|
|
|
|
PmPowerMgmtPhasesTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtPhasesTablePortNumber InterfaceIndex, -- serial port #
|
|
pmPowerMgmtPhasesTablePduNumber InterfaceIndex,
|
|
pmPowerMgmtPhasesTableNumber InterfaceIndex, -- phase number in PDU
|
|
pmPowerMgmtPhasesTableName DisplayString, -- phase sysname
|
|
pmPowerMgmtPhasesTablePortName DisplayString, -- serial port name
|
|
pmPowerMgmtPhasesTablePduId DisplayString, -- PDU ID
|
|
pmPowerMgmtPhasesTableAlarm INTEGER, -- phase alarm status
|
|
pmPowerMgmtPhasesTableCurrentValue Integer32, -- actual value for current of the sensor
|
|
pmPowerMgmtPhasesTableCurrentMax Integer32, -- max value for current
|
|
pmPowerMgmtPhasesTableCurrentMin Integer32, -- min value for current
|
|
pmPowerMgmtPhasesTableCurrentAvg Integer32, -- average value for current
|
|
pmPowerMgmtPhasesTableCurrentReset INTEGER, -- reset the current stats
|
|
pmPowerMgmtPhasesTablePowerValue Integer32, -- actual value for power
|
|
pmPowerMgmtPhasesTablePowerMax Integer32, -- max value for power
|
|
pmPowerMgmtPhasesTablePowerMin Integer32, -- min value for power
|
|
pmPowerMgmtPhasesTablePowerAvg Integer32, -- average value for power
|
|
pmPowerMgmtPhasesTablePowerReset INTEGER, -- reset the power stats
|
|
pmPowerMgmtPhasesTablePowerType INTEGER, -- power type
|
|
pmPowerMgmtPhasesTableVoltageValue Integer32, -- actual value for voltage
|
|
pmPowerMgmtPhasesTableVoltageMax Integer32, -- max value for voltage
|
|
pmPowerMgmtPhasesTableVoltageMin Integer32, -- min value for voltage
|
|
pmPowerMgmtPhasesTableVoltageAvg Integer32, -- average value for voltage
|
|
pmPowerMgmtPhasesTableVoltageReset INTEGER, -- reset the voltage stats
|
|
pmPowerMgmtPhasesTableVoltageType INTEGER, -- voltage type
|
|
pmPowerMgmtPhasesTablePowerFactorValue Integer32, -- actual value for powerfactor
|
|
pmPowerMgmtPhasesTablePowerFactorMax Integer32, -- max value for powerfactor
|
|
pmPowerMgmtPhasesTablePowerFactorMin Integer32, -- min value for powerfactor
|
|
pmPowerMgmtPhasesTablePowerFactorAvg Integer32, -- average value for powerfactor
|
|
pmPowerMgmtPhasesTablePowerFactorReset INTEGER, -- reset the powerfactor stats
|
|
pmPowerMgmtPhasesTablePowerFactorType INTEGER, -- power factor type
|
|
pmPowerMgmtPhasesTableCurrentHighCritical Integer32, -- outlet current high critical threshold
|
|
pmPowerMgmtPhasesTableCurrentHighWarning Integer32, -- outlet current high warning threshold
|
|
pmPowerMgmtPhasesTableCurrentLowWarning Integer32, -- outlet current low warning threshold
|
|
pmPowerMgmtPhasesTableCurrentLowCritical Integer32 -- outlet current low critical threshold
|
|
}
|
|
|
|
pmPowerMgmtPhasesTablePortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port number."
|
|
::= { pmPowerMgmtPhasesTableEntry 1 }
|
|
|
|
pmPowerMgmtPhasesTablePduNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index."
|
|
::= { pmPowerMgmtPhasesTableEntry 2 }
|
|
|
|
pmPowerMgmtPhasesTableNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the phase in the PDU."
|
|
::= { pmPowerMgmtPhasesTableEntry 3 }
|
|
|
|
pmPowerMgmtPhasesTableName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the phase.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtPhasesTableEntry 4 }
|
|
|
|
pmPowerMgmtPhasesTablePortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port Name where the PDU is connected."
|
|
::= { pmPowerMgmtPhasesTableEntry 5 }
|
|
|
|
pmPowerMgmtPhasesTablePduId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU identification."
|
|
::= { pmPowerMgmtPhasesTableEntry 6 }
|
|
|
|
pmPowerMgmtPhasesTableAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
blow-fuse (2),
|
|
hw-ocp (3),
|
|
high-critical (4),
|
|
high-warning (5),
|
|
low-warning (6),
|
|
low-critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the phase alarm status.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 45 }
|
|
|
|
--@ Note: Intentionally left space for future expansion
|
|
pmPowerMgmtPhasesTableCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of current in the phase (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 50 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of current in the phase (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 51 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of current in the phase (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 52 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of current in the phase (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 53 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPhasesTableEntry 54 }
|
|
|
|
pmPowerMgmtPhasesTablePowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power in the phase (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 60 }
|
|
|
|
pmPowerMgmtPhasesTablePowerMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power in the phase (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 61 }
|
|
|
|
pmPowerMgmtPhasesTablePowerMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power in the phase (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 62 }
|
|
|
|
pmPowerMgmtPhasesTablePowerAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power in the phase (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 63 }
|
|
|
|
pmPowerMgmtPhasesTablePowerReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPhasesTableEntry 64 }
|
|
|
|
pmPowerMgmtPhasesTablePowerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 65 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of voltage in the phase (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 70 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of voltage in the phase (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 71 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of voltage in the phase (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 72 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of voltage in the phase (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 73 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPhasesTableEntry 74 }
|
|
|
|
pmPowerMgmtPhasesTableVoltageType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of voltage values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 75 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power factor in the phase (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 80 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power factor in the phase (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 81 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power factor in the phase (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 82 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power factor in the phase (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 83 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtPhasesTableEntry 84 }
|
|
|
|
pmPowerMgmtPhasesTablePowerFactorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power factor values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 85 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentHighCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"phase high critical (alarm) current threshold (A x 10).
|
|
Set fails if value is lower that CurrentHighWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 100 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"phase high warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 101 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"phase low warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 102 }
|
|
|
|
pmPowerMgmtPhasesTableCurrentLowCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"phase low critical current threshold (A x 10).
|
|
Set fails if value is higher than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtPhasesTableEntry 103 }
|
|
|
|
--@ BANKS
|
|
|
|
pmPowerMgmtTotalNumberOfBanks OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of banks managed by the appliance."
|
|
::= { pmPowerMgmt 10 }
|
|
|
|
pmPowerMgmtBanksTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtBanksTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about banks."
|
|
::= { pmPowerMgmt 11 }
|
|
|
|
pmPowerMgmtBanksTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtBanksTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the banks."
|
|
INDEX { pmPowerMgmtBanksTablePortNumber,
|
|
pmPowerMgmtBanksTablePduNumber,
|
|
pmPowerMgmtBanksTableNumber }
|
|
::= { pmPowerMgmtBanksTable 1 }
|
|
|
|
PmPowerMgmtBanksTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtBanksTablePortNumber InterfaceIndex, -- serial port #
|
|
pmPowerMgmtBanksTablePduNumber InterfaceIndex,
|
|
pmPowerMgmtBanksTableNumber InterfaceIndex, -- bank number in PDU
|
|
pmPowerMgmtBanksTableName DisplayString, -- bank sysname
|
|
pmPowerMgmtBanksTablePortName DisplayString, -- serial port name
|
|
pmPowerMgmtBanksTablePduId DisplayString, -- PDU ID
|
|
pmPowerMgmtBanksTableAlarm INTEGER, -- bank alarm status
|
|
pmPowerMgmtBanksTableCurrentValue Integer32, -- actual value for current of the sensor
|
|
pmPowerMgmtBanksTableCurrentMax Integer32, -- max value for current
|
|
pmPowerMgmtBanksTableCurrentMin Integer32, -- min value for current
|
|
pmPowerMgmtBanksTableCurrentAvg Integer32, -- average value for current
|
|
pmPowerMgmtBanksTableCurrentReset INTEGER, -- reset current stats
|
|
pmPowerMgmtBanksTablePowerValue Integer32, -- actual value for power
|
|
pmPowerMgmtBanksTablePowerMax Integer32, -- max value for power
|
|
pmPowerMgmtBanksTablePowerMin Integer32, -- min value for power
|
|
pmPowerMgmtBanksTablePowerAvg Integer32, -- average value for power
|
|
pmPowerMgmtBanksTablePowerReset INTEGER, -- reset power stats
|
|
pmPowerMgmtBanksTablePowerType INTEGER, -- power type
|
|
pmPowerMgmtBanksTableVoltageValue Integer32, -- actual value for voltage
|
|
pmPowerMgmtBanksTableVoltageMax Integer32, -- max value for voltage
|
|
pmPowerMgmtBanksTableVoltageMin Integer32, -- min value for voltage
|
|
pmPowerMgmtBanksTableVoltageAvg Integer32, -- average value for voltage
|
|
pmPowerMgmtBanksTableVoltageReset INTEGER, -- reset voltage stats
|
|
pmPowerMgmtBanksTableVoltageType INTEGER, -- voltage type
|
|
pmPowerMgmtBanksTablePowerFactorValue Integer32, -- actual value for powerfactor
|
|
pmPowerMgmtBanksTablePowerFactorMax Integer32, -- max value for powerfactor
|
|
pmPowerMgmtBanksTablePowerFactorMin Integer32, -- min value for powerfactor
|
|
pmPowerMgmtBanksTablePowerFactorAvg Integer32, -- average value for powerfactor
|
|
pmPowerMgmtBanksTablePowerFactorReset INTEGER, -- reset powerfactor stats
|
|
pmPowerMgmtBanksTablePowerFactorType INTEGER, -- power factor type
|
|
pmPowerMgmtBanksTableCurrentHighCritical Integer32, -- outlet current high critical threshold
|
|
pmPowerMgmtBanksTableCurrentHighWarning Integer32, -- outlet current high warning threshold
|
|
pmPowerMgmtBanksTableCurrentLowWarning Integer32, -- outlet current low warning threshold
|
|
pmPowerMgmtBanksTableCurrentLowCritical Integer32, -- outlet current low critical threshold
|
|
pmPowerMgmtBanksTableEnergyValue Integer32, -- Energy value
|
|
pmPowerMgmtBanksTableEnergyStartTime DisplayString, -- time at which energy calculation commenced
|
|
pmPowerMgmtBanksTableEnergyReset INTEGER -- reset energy calculation and start time to now
|
|
}
|
|
|
|
pmPowerMgmtBanksTablePortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port number."
|
|
::= { pmPowerMgmtBanksTableEntry 1 }
|
|
|
|
pmPowerMgmtBanksTablePduNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index."
|
|
::= { pmPowerMgmtBanksTableEntry 2 }
|
|
|
|
pmPowerMgmtBanksTableNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the bank in the PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 3 }
|
|
|
|
pmPowerMgmtBanksTableName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the bank."
|
|
::= { pmPowerMgmtBanksTableEntry 4 }
|
|
|
|
pmPowerMgmtBanksTablePortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port Name where the PDU is connected."
|
|
::= { pmPowerMgmtBanksTableEntry 5 }
|
|
|
|
pmPowerMgmtBanksTablePduId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU identification."
|
|
::= { pmPowerMgmtBanksTableEntry 6 }
|
|
|
|
pmPowerMgmtBanksTableAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
blow-fuse (2),
|
|
hw-ocp (3),
|
|
high-critical (4),
|
|
high-warning (5),
|
|
low-warning (6),
|
|
low-critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the bank alarm status.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 45 }
|
|
|
|
|
|
--@ Note: Intentionally left space for future expansion
|
|
pmPowerMgmtBanksTableCurrentValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of current in the bank (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 50 }
|
|
|
|
pmPowerMgmtBanksTableCurrentMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of current in the bank (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 51 }
|
|
|
|
pmPowerMgmtBanksTableCurrentMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of current in the bank (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 52 }
|
|
|
|
pmPowerMgmtBanksTableCurrentAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of current in the bank (A x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 53 }
|
|
|
|
pmPowerMgmtBanksTableCurrentReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 54 }
|
|
|
|
pmPowerMgmtBanksTablePowerValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power in the bank (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 60 }
|
|
|
|
pmPowerMgmtBanksTablePowerMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power in the bank (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 61 }
|
|
|
|
pmPowerMgmtBanksTablePowerMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power in the bank (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 62 }
|
|
|
|
pmPowerMgmtBanksTablePowerAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power in the bank (W x 10).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 63 }
|
|
|
|
pmPowerMgmtBanksTablePowerReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 64 }
|
|
|
|
pmPowerMgmtBanksTablePowerType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 65 }
|
|
|
|
pmPowerMgmtBanksTableVoltageValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of voltage in the bank (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 70 }
|
|
|
|
pmPowerMgmtBanksTableVoltageMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of voltage in the bank (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 71 }
|
|
|
|
pmPowerMgmtBanksTableVoltageMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of voltage in the bank (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 72 }
|
|
|
|
pmPowerMgmtBanksTableVoltageAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of voltage in the bank (V).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 73 }
|
|
|
|
pmPowerMgmtBanksTableVoltageReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 74 }
|
|
|
|
pmPowerMgmtBanksTableVoltageType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of voltage values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 75 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of power factor in the bank (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 80 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of power factor in the bank (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 81 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of power factor in the bank (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 82 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorAvg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of power factor in the bank (Pf x 100).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 83 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 84 }
|
|
|
|
pmPowerMgmtBanksTablePowerFactorType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none-sensor (0),
|
|
estimated (1),
|
|
measured (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Type of power factor values.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 85 }
|
|
|
|
pmPowerMgmtBanksTableCurrentHighCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"bank high critical (alarm) current threshold (A x 10).
|
|
Set fails if value is lower that CurrentHighWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 100 }
|
|
|
|
pmPowerMgmtBanksTableCurrentHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"bank high warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighCritical or lower than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 101 }
|
|
|
|
pmPowerMgmtBanksTableCurrentLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"bank low warning current threshold (A x 10).
|
|
Set fails if value is higher than CurrentHighWarning or lower than CurrentLowCritical.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 102 }
|
|
|
|
pmPowerMgmtBanksTableCurrentLowCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"bank low critical current threshold (A x 10).
|
|
Set fails if value is higher than CurrentLowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 103 }
|
|
|
|
pmPowerMgmtBanksTableEnergyValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"bank energy value (Wh).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtBanksTableEntry 105 }
|
|
|
|
pmPowerMgmtBanksTableEnergyStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"time at which energy calculation commenced (ISO8601 format).
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtBanksTableEntry 106 }
|
|
|
|
pmPowerMgmtBanksTableEnergyReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to PDU."
|
|
::= { pmPowerMgmtBanksTableEntry 107 }
|
|
|
|
--@ Sensors
|
|
|
|
pmPowerMgmtTotalNumberOfSensors OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Sensors managed by the appliance."
|
|
::= { pmPowerMgmt 12 }
|
|
|
|
pmPowerMgmtSensorsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PmPowerMgmtSensorsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the information about sensors."
|
|
::= { pmPowerMgmt 13 }
|
|
|
|
pmPowerMgmtSensorsTableEntry OBJECT-TYPE
|
|
SYNTAX PmPowerMgmtSensorsTableEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"each entry has the information about the sensors."
|
|
INDEX { pmPowerMgmtSensorsTablePortNumber,
|
|
pmPowerMgmtSensorsTablePduNumber,
|
|
pmPowerMgmtSensorsTableNumber }
|
|
::= { pmPowerMgmtSensorsTable 1 }
|
|
|
|
PmPowerMgmtSensorsTableEntry ::= SEQUENCE {
|
|
pmPowerMgmtSensorsTablePortNumber InterfaceIndex, -- serial port #
|
|
pmPowerMgmtSensorsTablePduNumber InterfaceIndex,
|
|
pmPowerMgmtSensorsTableNumber InterfaceIndex, -- sensor number in PDU
|
|
pmPowerMgmtSensorsTableName DisplayString, -- sensor name
|
|
pmPowerMgmtSensorsTablePortName DisplayString, -- serial port name
|
|
pmPowerMgmtSensorsTablePduId DisplayString, -- PDU ID
|
|
pmPowerMgmtSensorsTableType INTEGER, -- sensor type
|
|
pmPowerMgmtSensorsTableStatus INTEGER, -- digital sensor status
|
|
pmPowerMgmtSensorsTableValue DisplayString, -- actual value for current of the sensor
|
|
pmPowerMgmtSensorsTableValueMax DisplayString, -- max value for current
|
|
pmPowerMgmtSensorsTableValueMin DisplayString, -- min value for current
|
|
pmPowerMgmtSensorsTableValueAvg DisplayString, -- average value for current
|
|
pmPowerMgmtSensorsTableValueInt Integer32, -- actual value for current of the sensor
|
|
pmPowerMgmtSensorsTableValueMaxInt Integer32, -- max value for current
|
|
pmPowerMgmtSensorsTableValueMinInt Integer32, -- min value for current
|
|
pmPowerMgmtSensorsTableValueAvgInt Integer32, -- average value for current
|
|
pmPowerMgmtSensorsTableValueReset INTEGER, -- reset current stats
|
|
pmPowerMgmtSensorsTableHighCritical Integer32, -- set/get sensor high critical threshold
|
|
pmPowerMgmtSensorsTableHighWarning Integer32, -- set/get sensor high warning threshold
|
|
pmPowerMgmtSensorsTableLowWarning Integer32, -- set/get sensor low warning threshold
|
|
pmPowerMgmtSensorsTableLowCritical Integer32, -- set/get sensor low critical threshold
|
|
pmPowerMgmtSensorsTableUnit INTEGER, -- set/get sensor unit of measurement
|
|
pmPowerMgmtSensorsTableHighCriticalC Integer32, -- get sensor high critical threshold
|
|
pmPowerMgmtSensorsTableHighWarningC Integer32, -- get sensor high warning threshold
|
|
pmPowerMgmtSensorsTableLowWarningC Integer32, -- get sensor low warning threshold
|
|
pmPowerMgmtSensorsTableLowCriticalC Integer32, -- get sensor low critical threshold
|
|
pmPowerMgmtSensorsTableHighCriticalF Integer32, -- get sensor high critical threshold
|
|
pmPowerMgmtSensorsTableHighWarningF Integer32, -- get sensor high warning threshold
|
|
pmPowerMgmtSensorsTableLowWarningF Integer32, -- get sensor low warning threshold
|
|
pmPowerMgmtSensorsTableLowCriticalF Integer32 -- get sensor low critical threshold
|
|
}
|
|
|
|
pmPowerMgmtSensorsTablePortNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port number."
|
|
::= { pmPowerMgmtSensorsTableEntry 1 }
|
|
|
|
pmPowerMgmtSensorsTablePduNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index."
|
|
::= { pmPowerMgmtSensorsTableEntry 2 }
|
|
|
|
pmPowerMgmtSensorsTableNumber OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of the sensor in the PDU."
|
|
::= { pmPowerMgmtSensorsTableEntry 3 }
|
|
|
|
pmPowerMgmtSensorsTableName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the sensor."
|
|
::= { pmPowerMgmtSensorsTableEntry 4 }
|
|
|
|
pmPowerMgmtSensorsTablePortName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Serial Port Name where the PDU is connected."
|
|
::= { pmPowerMgmtSensorsTableEntry 5 }
|
|
|
|
pmPowerMgmtSensorsTablePduId OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PDU identification."
|
|
::= { pmPowerMgmtSensorsTableEntry 6 }
|
|
|
|
pmPowerMgmtSensorsTableType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
temp-internal (1),
|
|
temperature (2),
|
|
humidity (3),
|
|
air-flow (4),
|
|
smoke (5),
|
|
dry-concact (6),
|
|
water-level (7),
|
|
motion (8),
|
|
unplugged (9),
|
|
unknown (10)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of environmental monitor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 7 }
|
|
|
|
pmPowerMgmtSensorsTableStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(1),
|
|
triggered(2),
|
|
not-applicable(3),
|
|
opened(4),
|
|
closed(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of digital sensors: Dry-Contact, Water level, Smoke sensor, Motion sensor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 8 }
|
|
|
|
|
|
--@ Note: Intentionally left space for future expansion
|
|
pmPowerMgmtSensorsTableValue OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of the sensor.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtSensorsTableEntry 20 }
|
|
|
|
pmPowerMgmtSensorsTableValueMax OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of the sensor.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtSensorsTableEntry 21 }
|
|
|
|
pmPowerMgmtSensorsTableValueMin OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of the sensor.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtSensorsTableEntry 22 }
|
|
|
|
pmPowerMgmtSensorsTableValueAvg OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of the sensor.
|
|
Returns N/A if not applicable."
|
|
::= { pmPowerMgmtSensorsTableEntry 23 }
|
|
|
|
pmPowerMgmtSensorsTableValueInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Actual value of the sensor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 25 }
|
|
|
|
pmPowerMgmtSensorsTableValueMaxInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of the sensor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 26 }
|
|
|
|
pmPowerMgmtSensorsTableValueMinInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum value of the sensor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 27 }
|
|
|
|
pmPowerMgmtSensorsTableValueAvgInt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Average value of the sensor.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 28 }
|
|
|
|
pmPowerMgmtSensorsTableValueReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noAction(1),
|
|
reset(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"noAction(1) = always returned in a GET. Does nothing if SET.
|
|
reset(2) = when SET the reset command is sent to sensor."
|
|
::= { pmPowerMgmtSensorsTableEntry 30 }
|
|
|
|
pmPowerMgmtSensorsTableHighCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high critical (alarm) threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
|
|
Set fails if value is lower that CurrentHighWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 40 }
|
|
|
|
pmPowerMgmtSensorsTableHighWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
|
|
Set fails if value is higher than HighCritical or lower than LowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 41 }
|
|
|
|
pmPowerMgmtSensorsTableLowWarning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low warning threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
|
|
Set fails if value is higher than HighWarning or lower than LowCritical.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 42 }
|
|
|
|
pmPowerMgmtSensorsTableLowCritical OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low critical threshold (unit x 10) - use unit as returned by pmPowerMgmtSensorsTableUnit.
|
|
Set fails if value is higher than LowWarning.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 43 }
|
|
|
|
pmPowerMgmtSensorsTableUnit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
undefined (1),
|
|
fahrenheit (2),
|
|
celsius (3),
|
|
percent (4),
|
|
afu (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor unit.
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 45 }
|
|
|
|
pmPowerMgmtSensorsTableHighCriticalC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high critical (alarm) threshold (Celcius x 10).
|
|
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 50 }
|
|
|
|
pmPowerMgmtSensorsTableHighWarningC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high warning threshold (Celcius x 10).
|
|
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 51 }
|
|
|
|
pmPowerMgmtSensorsTableLowWarningC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low warning threshold (Celcius x 10).
|
|
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 52 }
|
|
|
|
pmPowerMgmtSensorsTableLowCriticalC OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low critical threshold (Celcius x 10).
|
|
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 53 }
|
|
|
|
pmPowerMgmtSensorsTableHighCriticalF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high critical (alarm) threshold (Fahrenheit x 10).
|
|
to SET: use pmPowerMgmtSensorsTableHighCritical in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 60 }
|
|
|
|
pmPowerMgmtSensorsTableHighWarningF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor high warning threshold (Fahrenheit x 10).
|
|
to SET: use pmPowerMgmtSensorsTableHighWarning in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 61 }
|
|
|
|
pmPowerMgmtSensorsTableLowWarningF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low warning threshold (Fahrenheit x 10).
|
|
to SET: use pmPowerMgmtSensorsTableLowWarning in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 62 }
|
|
|
|
pmPowerMgmtSensorsTableLowCriticalF OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"sensor low critical threshold (Fahrenheit x 10).
|
|
to SET: use pmPowerMgmtSensorsTableLowCritical in proper units (pmPowerMgmtSensorsTableUnit).
|
|
Returns 0 if not supported."
|
|
::= { pmPowerMgmtSensorsTableEntry 63 }
|
|
|
|
END
|