- Remove PVC volume mount from k8s/deployment.yaml - Delete k8s/mib-pvc.yaml (no longer needed) - Update .gitignore to commit MIB files to git - Add mix import_mibs task to copy MIBs from LibreNMS - Add all MIB files from priv/mibs/ to git This fixes the multi-attach volume error in Kubernetes where new pods couldn't start because the RWO (ReadWriteOnce) PVC was attached to the old pod. MIBs are now part of the Docker image and can be used by all pods simultaneously.
2838 lines
76 KiB
Text
2838 lines
76 KiB
Text
|
|
AC-PM-SS7-MIB DEFINITIONS ::= BEGIN
|
|
|
|
|
|
IMPORTS
|
|
|
|
|
|
OBJECT-TYPE,
|
|
MODULE-IDENTITY FROM SNMPv2-SMI
|
|
TAddress,
|
|
DisplayString,
|
|
DateAndTime, TEXTUAL-CONVENTION FROM SNMPv2-TC
|
|
IpAddress FROM RFC1155-SMI
|
|
Unsigned32,
|
|
Integer32,
|
|
enterprises FROM SNMPv2-SMI
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
audioCodes,
|
|
acRegistrations,
|
|
acGeneric,
|
|
acProducts,acBoardMibs,acPerformance FROM AUDIOCODES-TYPES-MIB;
|
|
|
|
|
|
acPMSS7 MODULE-IDENTITY
|
|
LAST-UPDATED "201711020808Z" --Thursday, November 2, 2017
|
|
ORGANIZATION "AudioCodes Ltd"
|
|
CONTACT-INFO
|
|
"Postal: Support
|
|
AudioCodes LTD
|
|
1 Hayarden Street
|
|
Airport City
|
|
Lod, ISRAEL 70151
|
|
Tel: 972-3-9764000
|
|
Fax: 972-3-9764040
|
|
Email: support@audiocodes.com
|
|
Web: www.audiocodes.com"
|
|
|
|
|
|
DESCRIPTION
|
|
"The AC-PM-SS7 MIB offers performance monitoring
|
|
For the SS7 related elements in Audiocodes' devices.
|
|
The Configuration sub-tree is for configuring the interval
|
|
Period length for the entire AC-PM-SS7 MIB, and the
|
|
different tables' thresholds.
|
|
The Data sub-tree presents the tables of monitored
|
|
elements.
|
|
|
|
Note - for the entire MIB the value (-1) means the value
|
|
Asked for is either not supported or currently not relevant
|
|
(this is for when values asked for are for intervals not yet
|
|
recorded."
|
|
|
|
|
|
REVISION "202102160955Z" --Tuesday, February 16 2021
|
|
DESCRIPTION "obsoleted acPMSS7"
|
|
|
|
|
|
::= {acPerformance 13}
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
acPMSS7Configuration OBJECT IDENTIFIER ::= {acPMSS7 1}
|
|
|
|
|
|
acPMSS7ConfigurationPeriodLength OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..894780)
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Length of monitoring intervals for entire MIB. Time is in minutes.
|
|
Access: Online."
|
|
::= {acPMSS7Configuration 1}
|
|
|
|
|
|
|
|
acPMSS7ConfigurationResetTotalCounters OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
resetCountersDone(1)
|
|
,
|
|
resetTotalCounters(2)
|
|
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total-Counters Reset. To reset the total counters, set the
|
|
value of this object to resetTotalCounters(2).
|
|
Access: Online."
|
|
::= {acPMSS7Configuration 2}
|
|
|
|
|
|
|
|
acPMSS7Data OBJECT IDENTIFIER ::= {acPMSS7 2}
|
|
|
|
|
|
acPMSS7DataTimeFromStartOfInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The time in seconds since the start of the current interval.
|
|
MIB specific."
|
|
::= {acPMSS7Data 1}
|
|
|
|
|
|
|
|
acPMSS7Links OBJECT IDENTIFIER ::= {acPMSS7Data 31}
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMSU table declaration
|
|
-- ****************************************
|
|
acPMSS7TxMSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted MSU's per SS7 link."
|
|
::= {acPMSS7Links 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMSU table entry
|
|
-- ****************************************
|
|
acPMSS7TxMSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxMSULink,acPMSS7TxMSUInterval}
|
|
::= {acPMSS7TxMSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxMSUEntry ::= SEQUENCE {
|
|
acPMSS7TxMSULink Unsigned32,
|
|
acPMSS7TxMSUInterval Unsigned32,
|
|
acPMSS7TxMSUVal Counter32,
|
|
acPMSS7TxMSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxMSULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7TxMSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxMSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxMSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxMSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxMSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxMSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxMSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMSU table declaration
|
|
-- ****************************************
|
|
acPMSS7RxMSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received MSU's per SS7 link."
|
|
::= {acPMSS7Links 2}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMSU table entry
|
|
-- ****************************************
|
|
acPMSS7RxMSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxMSULink,acPMSS7RxMSUInterval}
|
|
::= {acPMSS7RxMSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxMSUEntry ::= SEQUENCE {
|
|
acPMSS7RxMSULink Unsigned32,
|
|
acPMSS7RxMSUInterval Unsigned32,
|
|
acPMSS7RxMSUVal Counter32,
|
|
acPMSS7RxMSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxMSULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7RxMSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxMSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxMSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxMSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxMSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxMSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxMSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxLSSU table declaration
|
|
-- ****************************************
|
|
acPMSS7TxLSSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxLSSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted LSSU's per SS7 link."
|
|
::= {acPMSS7Links 3}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxLSSU table entry
|
|
-- ****************************************
|
|
acPMSS7TxLSSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxLSSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxLSSULink,acPMSS7TxLSSUInterval}
|
|
::= {acPMSS7TxLSSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxLSSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxLSSUEntry ::= SEQUENCE {
|
|
acPMSS7TxLSSULink Unsigned32,
|
|
acPMSS7TxLSSUInterval Unsigned32,
|
|
acPMSS7TxLSSUVal Counter32,
|
|
acPMSS7TxLSSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxLSSULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7TxLSSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxLSSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxLSSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxLSSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxLSSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxLSSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxLSSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxLSSU table declaration
|
|
-- ****************************************
|
|
acPMSS7RxLSSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxLSSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received LSSU's per SS7 link."
|
|
::= {acPMSS7Links 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxLSSU table entry
|
|
-- ****************************************
|
|
acPMSS7RxLSSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxLSSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxLSSULink,acPMSS7RxLSSUInterval}
|
|
::= {acPMSS7RxLSSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxLSSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxLSSUEntry ::= SEQUENCE {
|
|
acPMSS7RxLSSULink Unsigned32,
|
|
acPMSS7RxLSSUInterval Unsigned32,
|
|
acPMSS7RxLSSUVal Counter32,
|
|
acPMSS7RxLSSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxLSSULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7RxLSSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxLSSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxLSSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxLSSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxLSSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxLSSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxLSSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxFISU table declaration
|
|
-- ****************************************
|
|
acPMSS7TxFISUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxFISUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted FISU's per SS7 link."
|
|
::= {acPMSS7Links 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxFISU table entry
|
|
-- ****************************************
|
|
acPMSS7TxFISUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxFISUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxFISULink,acPMSS7TxFISUInterval}
|
|
::= {acPMSS7TxFISUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxFISU TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxFISUEntry ::= SEQUENCE {
|
|
acPMSS7TxFISULink Unsigned32,
|
|
acPMSS7TxFISUInterval Unsigned32,
|
|
acPMSS7TxFISUVal Counter32,
|
|
acPMSS7TxFISUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxFISULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7TxFISUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxFISUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxFISUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxFISUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxFISUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxFISUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxFISUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxFISU table declaration
|
|
-- ****************************************
|
|
acPMSS7RxFISUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxFISUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received FISU's per SS7 link."
|
|
::= {acPMSS7Links 6}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxFISU table entry
|
|
-- ****************************************
|
|
acPMSS7RxFISUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxFISUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxFISULink,acPMSS7RxFISUInterval}
|
|
::= {acPMSS7RxFISUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxFISU TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxFISUEntry ::= SEQUENCE {
|
|
acPMSS7RxFISULink Unsigned32,
|
|
acPMSS7RxFISUInterval Unsigned32,
|
|
acPMSS7RxFISUVal Counter32,
|
|
acPMSS7RxFISUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxFISULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7RxFISUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxFISUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxFISUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxFISUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxFISUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxFISUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxFISUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxSignalUnits table declaration
|
|
-- ****************************************
|
|
acPMSS7TxSignalUnitsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxSignalUnitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted Signaling units per SS7 link"
|
|
::= {acPMSS7Links 7}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxSignalUnits table entry
|
|
-- ****************************************
|
|
acPMSS7TxSignalUnitsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxSignalUnitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxSignalUnitsLink,acPMSS7TxSignalUnitsInterval}
|
|
::= {acPMSS7TxSignalUnitsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxSignalUnits TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxSignalUnitsEntry ::= SEQUENCE {
|
|
acPMSS7TxSignalUnitsLink Unsigned32,
|
|
acPMSS7TxSignalUnitsInterval Unsigned32,
|
|
acPMSS7TxSignalUnitsVal Counter32,
|
|
acPMSS7TxSignalUnitsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxSignalUnitsLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7TxSignalUnitsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxSignalUnitsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxSignalUnitsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxSignalUnitsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxSignalUnitsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxSignalUnitsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxSignalUnitsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxSignalUnits table declaration
|
|
-- ****************************************
|
|
acPMSS7RxSignalUnitsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxSignalUnitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received Signaling units per SS7 link"
|
|
::= {acPMSS7Links 8}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxSignalUnits table entry
|
|
-- ****************************************
|
|
acPMSS7RxSignalUnitsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxSignalUnitsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxSignalUnitsLink,acPMSS7RxSignalUnitsInterval}
|
|
::= {acPMSS7RxSignalUnitsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxSignalUnits TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxSignalUnitsEntry ::= SEQUENCE {
|
|
acPMSS7RxSignalUnitsLink Unsigned32,
|
|
acPMSS7RxSignalUnitsInterval Unsigned32,
|
|
acPMSS7RxSignalUnitsVal Counter32,
|
|
acPMSS7RxSignalUnitsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxSignalUnitsLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7RxSignalUnitsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxSignalUnitsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxSignalUnitsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxSignalUnitsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxSignalUnitsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxSignalUnitsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxSignalUnitsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxOctets table declaration
|
|
-- ****************************************
|
|
acPMSS7TxOctetsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxOctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted Octets per SS7 link - Q.752 3.1"
|
|
::= {acPMSS7Links 9}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxOctets table entry
|
|
-- ****************************************
|
|
acPMSS7TxOctetsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxOctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxOctetsLink,acPMSS7TxOctetsInterval}
|
|
::= {acPMSS7TxOctetsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxOctets TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxOctetsEntry ::= SEQUENCE {
|
|
acPMSS7TxOctetsLink Unsigned32,
|
|
acPMSS7TxOctetsInterval Unsigned32,
|
|
acPMSS7TxOctetsVal Counter32,
|
|
acPMSS7TxOctetsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxOctetsLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7TxOctetsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxOctetsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxOctetsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxOctetsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxOctetsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxOctetsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxOctetsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxOctets table declaration
|
|
-- ****************************************
|
|
acPMSS7RxOctetsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxOctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received Octets per SS7 link - Q.752 3.4"
|
|
::= {acPMSS7Links 10}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxOctets table entry
|
|
-- ****************************************
|
|
acPMSS7RxOctetsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxOctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxOctetsLink,acPMSS7RxOctetsInterval}
|
|
::= {acPMSS7RxOctetsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxOctets TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxOctetsEntry ::= SEQUENCE {
|
|
acPMSS7RxOctetsLink Unsigned32,
|
|
acPMSS7RxOctetsInterval Unsigned32,
|
|
acPMSS7RxOctetsVal Counter32,
|
|
acPMSS7RxOctetsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxOctetsLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7RxOctetsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxOctetsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxOctetsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxOctetsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxOctetsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxOctetsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxOctetsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2NoAckRx table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2NoAckRxTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2NoAckRxEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 Not Ack received (from far end) per SS7 link - Q.752 1.9"
|
|
::= {acPMSS7Links 11}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2NoAckRx table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2NoAckRxEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2NoAckRxEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2NoAckRxLink,acPMSS7MTP2NoAckRxInterval}
|
|
::= {acPMSS7MTP2NoAckRxTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2NoAckRx TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2NoAckRxEntry ::= SEQUENCE {
|
|
acPMSS7MTP2NoAckRxLink Unsigned32,
|
|
acPMSS7MTP2NoAckRxInterval Unsigned32,
|
|
acPMSS7MTP2NoAckRxVal Counter32,
|
|
acPMSS7MTP2NoAckRxTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2NoAckRxLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2NoAckRxEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2NoAckRxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2NoAckRxEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2NoAckRxVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2NoAckRxEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2NoAckRxTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2NoAckRxEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7DiscMSU table declaration
|
|
-- ****************************************
|
|
acPMSS7DiscMSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7DiscMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MSUs discarded due to SL congestion - transmit and receive - Q.752 3.10"
|
|
::= {acPMSS7Links 12}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7DiscMSU table entry
|
|
-- ****************************************
|
|
acPMSS7DiscMSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7DiscMSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7DiscMSULink,acPMSS7DiscMSUInterval}
|
|
::= {acPMSS7DiscMSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7DiscMSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7DiscMSUEntry ::= SEQUENCE {
|
|
acPMSS7DiscMSULink Unsigned32,
|
|
acPMSS7DiscMSUInterval Unsigned32,
|
|
acPMSS7DiscMSUVal Counter32,
|
|
acPMSS7DiscMSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7DiscMSULink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7DiscMSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7DiscMSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7DiscMSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7DiscMSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7DiscMSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7DiscMSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7DiscMSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7InService table declaration
|
|
-- ****************************************
|
|
acPMSS7InServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7InServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Duration of SS7 link at in-service state in percentage (in last 30 minutes) - Q.752 1.1"
|
|
::= {acPMSS7Links 13}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7InService table entry
|
|
-- ****************************************
|
|
acPMSS7InServiceEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7InServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7InServiceLink,acPMSS7InServiceInterval}
|
|
::= {acPMSS7InServiceTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7InService TABLE
|
|
-- ****************************************
|
|
AcPMSS7InServiceEntry ::= SEQUENCE {
|
|
acPMSS7InServiceLink Unsigned32,
|
|
acPMSS7InServiceInterval Unsigned32,
|
|
acPMSS7InServiceVal Gauge32,
|
|
acPMSS7InServiceTimeAboveHighThreshold Integer32,
|
|
acPMSS7InServiceTimeBetweenThresholds Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7InServiceLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7InServiceEntry 1}
|
|
|
|
|
|
|
|
acPMSS7InServiceInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7InServiceEntry 2}
|
|
|
|
|
|
|
|
acPMSS7InServiceVal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7InServiceEntry 3}
|
|
|
|
|
|
|
|
acPMSS7InServiceTimeAboveHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is above what was determined
|
|
as the high threshold. In this case - 'In Service'."
|
|
::= {acPMSS7InServiceEntry 4}
|
|
|
|
|
|
|
|
acPMSS7InServiceTimeBetweenThresholds OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is between what were
|
|
determined as the low and high thresholds. In this case -
|
|
not 'In Service'."
|
|
::= {acPMSS7InServiceEntry 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7OutOfService table declaration
|
|
-- ****************************************
|
|
acPMSS7OutOfServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7OutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Duration of SS7 link at out-of-service state in percentage (in last 30 minutes) - Q.752 2.1"
|
|
::= {acPMSS7Links 14}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7OutOfService table entry
|
|
-- ****************************************
|
|
acPMSS7OutOfServiceEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7OutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7OutOfServiceLink,acPMSS7OutOfServiceInterval}
|
|
::= {acPMSS7OutOfServiceTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7OutOfService TABLE
|
|
-- ****************************************
|
|
AcPMSS7OutOfServiceEntry ::= SEQUENCE {
|
|
acPMSS7OutOfServiceLink Unsigned32,
|
|
acPMSS7OutOfServiceInterval Unsigned32,
|
|
acPMSS7OutOfServiceVal Gauge32,
|
|
acPMSS7OutOfServiceTimeAboveHighThreshold Integer32,
|
|
acPMSS7OutOfServiceTimeBetweenThresholds Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7OutOfServiceLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7OutOfServiceEntry 1}
|
|
|
|
|
|
|
|
acPMSS7OutOfServiceInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7OutOfServiceEntry 2}
|
|
|
|
|
|
|
|
acPMSS7OutOfServiceVal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7OutOfServiceEntry 3}
|
|
|
|
|
|
|
|
acPMSS7OutOfServiceTimeAboveHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is above what was determined
|
|
as the high threshold. In this case - 'Out Of Service'."
|
|
::= {acPMSS7OutOfServiceEntry 4}
|
|
|
|
|
|
|
|
acPMSS7OutOfServiceTimeBetweenThresholds OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is between what were
|
|
determined as the low and high thresholds. In this case -
|
|
not 'Out of Service'."
|
|
::= {acPMSS7OutOfServiceEntry 5}
|
|
|
|
|
|
|
|
acPMSS7LinkSets OBJECT IDENTIFIER ::= {acPMSS7Data 41}
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN0LSOutOfService table declaration
|
|
-- ****************************************
|
|
acPMSS7SN0LSOutOfServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7SN0LSOutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Duration of SS7 linkSet within Signaling node 0 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
|
|
::= {acPMSS7LinkSets 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN0LSOutOfService table entry
|
|
-- ****************************************
|
|
acPMSS7SN0LSOutOfServiceEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7SN0LSOutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7SN0LSOutOfServiceLinkSet,acPMSS7SN0LSOutOfServiceInterval}
|
|
::= {acPMSS7SN0LSOutOfServiceTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN0LSOutOfService TABLE
|
|
-- ****************************************
|
|
AcPMSS7SN0LSOutOfServiceEntry ::= SEQUENCE {
|
|
acPMSS7SN0LSOutOfServiceLinkSet Unsigned32,
|
|
acPMSS7SN0LSOutOfServiceInterval Unsigned32,
|
|
acPMSS7SN0LSOutOfServiceVal Gauge32,
|
|
acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold Integer32,
|
|
acPMSS7SN0LSOutOfServiceTimeBetweenThresholds Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7SN0LSOutOfServiceLinkSet OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link Set number.
|
|
0 is the first link."
|
|
::= {acPMSS7SN0LSOutOfServiceEntry 1}
|
|
|
|
|
|
|
|
acPMSS7SN0LSOutOfServiceInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7SN0LSOutOfServiceEntry 2}
|
|
|
|
|
|
|
|
acPMSS7SN0LSOutOfServiceVal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7SN0LSOutOfServiceEntry 3}
|
|
|
|
|
|
|
|
acPMSS7SN0LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is above what was determined
|
|
as the high threshold. In this case - 'Out Of Service'."
|
|
::= {acPMSS7SN0LSOutOfServiceEntry 4}
|
|
|
|
|
|
|
|
acPMSS7SN0LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is between what were
|
|
determined as the low and high thresholds. In this case -
|
|
not 'Out of Service'."
|
|
::= {acPMSS7SN0LSOutOfServiceEntry 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN1LSOutOfService table declaration
|
|
-- ****************************************
|
|
acPMSS7SN1LSOutOfServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7SN1LSOutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Duration of SS7 linkSet within Signaling node 1 at Out-of-service state in percentage (in last 30 minutes) -Q.752 5.2"
|
|
::= {acPMSS7LinkSets 2}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN1LSOutOfService table entry
|
|
-- ****************************************
|
|
acPMSS7SN1LSOutOfServiceEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7SN1LSOutOfServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7SN1LSOutOfServiceLinkSet,acPMSS7SN1LSOutOfServiceInterval}
|
|
::= {acPMSS7SN1LSOutOfServiceTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7SN1LSOutOfService TABLE
|
|
-- ****************************************
|
|
AcPMSS7SN1LSOutOfServiceEntry ::= SEQUENCE {
|
|
acPMSS7SN1LSOutOfServiceLinkSet Unsigned32,
|
|
acPMSS7SN1LSOutOfServiceInterval Unsigned32,
|
|
acPMSS7SN1LSOutOfServiceVal Gauge32,
|
|
acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold Integer32,
|
|
acPMSS7SN1LSOutOfServiceTimeBetweenThresholds Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7SN1LSOutOfServiceLinkSet OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..31)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link Set number.
|
|
0 is the first link."
|
|
::= {acPMSS7SN1LSOutOfServiceEntry 1}
|
|
|
|
|
|
|
|
acPMSS7SN1LSOutOfServiceInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7SN1LSOutOfServiceEntry 2}
|
|
|
|
|
|
|
|
acPMSS7SN1LSOutOfServiceVal OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7SN1LSOutOfServiceEntry 3}
|
|
|
|
|
|
|
|
acPMSS7SN1LSOutOfServiceTimeAboveHighThreshold OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is above what was determined
|
|
as the high threshold. In this case - 'Out Of Service'."
|
|
::= {acPMSS7SN1LSOutOfServiceEntry 4}
|
|
|
|
|
|
|
|
acPMSS7SN1LSOutOfServiceTimeBetweenThresholds OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..100)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Percent of interval time for which gauge is between what were
|
|
determined as the low and high thresholds. In this case -
|
|
not 'Out of Service'."
|
|
::= {acPMSS7SN1LSOutOfServiceEntry 5}
|
|
|
|
|
|
|
|
acPMSS7SignalingNodes OBJECT IDENTIFIER ::= {acPMSS7Data 51}
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3Octets table declaration
|
|
-- ****************************************
|
|
acPMSS7TxMTP3OctetsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxMTP3OctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted MTP3 octets per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3Octets table entry
|
|
-- ****************************************
|
|
acPMSS7TxMTP3OctetsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxMTP3OctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxMTP3OctetsSN,acPMSS7TxMTP3OctetsInterval}
|
|
::= {acPMSS7TxMTP3OctetsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3Octets TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxMTP3OctetsEntry ::= SEQUENCE {
|
|
acPMSS7TxMTP3OctetsSN Unsigned32,
|
|
acPMSS7TxMTP3OctetsInterval Unsigned32,
|
|
acPMSS7TxMTP3OctetsVal Counter32,
|
|
acPMSS7TxMTP3OctetsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3OctetsSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7TxMTP3OctetsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3OctetsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxMTP3OctetsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3OctetsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxMTP3OctetsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3OctetsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxMTP3OctetsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3Octets table declaration
|
|
-- ****************************************
|
|
acPMSS7RxMTP3OctetsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxMTP3OctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received MTP3 octets per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 2}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3Octets table entry
|
|
-- ****************************************
|
|
acPMSS7RxMTP3OctetsEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxMTP3OctetsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxMTP3OctetsSN,acPMSS7RxMTP3OctetsInterval}
|
|
::= {acPMSS7RxMTP3OctetsTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3Octets TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxMTP3OctetsEntry ::= SEQUENCE {
|
|
acPMSS7RxMTP3OctetsSN Unsigned32,
|
|
acPMSS7RxMTP3OctetsInterval Unsigned32,
|
|
acPMSS7RxMTP3OctetsVal Counter32,
|
|
acPMSS7RxMTP3OctetsTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3OctetsSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7RxMTP3OctetsEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3OctetsInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxMTP3OctetsEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3OctetsVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxMTP3OctetsEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3OctetsTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxMTP3OctetsEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3MSU table declaration
|
|
-- ****************************************
|
|
acPMSS7TxMTP3MSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxMTP3MSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted MTP3 MSU's per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 3}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3MSU table entry
|
|
-- ****************************************
|
|
acPMSS7TxMTP3MSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxMTP3MSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxMTP3MSUSN,acPMSS7TxMTP3MSUInterval}
|
|
::= {acPMSS7TxMTP3MSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3MSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxMTP3MSUEntry ::= SEQUENCE {
|
|
acPMSS7TxMTP3MSUSN Unsigned32,
|
|
acPMSS7TxMTP3MSUInterval Unsigned32,
|
|
acPMSS7TxMTP3MSUVal Counter32,
|
|
acPMSS7TxMTP3MSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3MSUSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7TxMTP3MSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3MSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxMTP3MSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3MSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxMTP3MSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3MSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxMTP3MSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3MSU table declaration
|
|
-- ****************************************
|
|
acPMSS7RxMTP3MSUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxMTP3MSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received MTP3 MSU's per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3MSU table entry
|
|
-- ****************************************
|
|
acPMSS7RxMTP3MSUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxMTP3MSUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxMTP3MSUSN,acPMSS7RxMTP3MSUInterval}
|
|
::= {acPMSS7RxMTP3MSUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3MSU TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxMTP3MSUEntry ::= SEQUENCE {
|
|
acPMSS7RxMTP3MSUSN Unsigned32,
|
|
acPMSS7RxMTP3MSUInterval Unsigned32,
|
|
acPMSS7RxMTP3MSUVal Counter32,
|
|
acPMSS7RxMTP3MSUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3MSUSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7RxMTP3MSUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3MSUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxMTP3MSUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3MSUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxMTP3MSUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3MSUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxMTP3MSUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3UPU table declaration
|
|
-- ****************************************
|
|
acPMSS7TxMTP3UPUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7TxMTP3UPUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of transmitted MTP3 User Part Unavailable messages per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3UPU table entry
|
|
-- ****************************************
|
|
acPMSS7TxMTP3UPUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7TxMTP3UPUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7TxMTP3UPUSN,acPMSS7TxMTP3UPUInterval}
|
|
::= {acPMSS7TxMTP3UPUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7TxMTP3UPU TABLE
|
|
-- ****************************************
|
|
AcPMSS7TxMTP3UPUEntry ::= SEQUENCE {
|
|
acPMSS7TxMTP3UPUSN Unsigned32,
|
|
acPMSS7TxMTP3UPUInterval Unsigned32,
|
|
acPMSS7TxMTP3UPUVal Counter32,
|
|
acPMSS7TxMTP3UPUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3UPUSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7TxMTP3UPUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3UPUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7TxMTP3UPUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3UPUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7TxMTP3UPUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7TxMTP3UPUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7TxMTP3UPUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3UPU table declaration
|
|
-- ****************************************
|
|
acPMSS7RxMTP3UPUTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxMTP3UPUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of received MTP3 User Part Unavailable messages per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 6}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3UPU table entry
|
|
-- ****************************************
|
|
acPMSS7RxMTP3UPUEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxMTP3UPUEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxMTP3UPUSN,acPMSS7RxMTP3UPUInterval}
|
|
::= {acPMSS7RxMTP3UPUTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3UPU TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxMTP3UPUEntry ::= SEQUENCE {
|
|
acPMSS7RxMTP3UPUSN Unsigned32,
|
|
acPMSS7RxMTP3UPUInterval Unsigned32,
|
|
acPMSS7RxMTP3UPUVal Counter32,
|
|
acPMSS7RxMTP3UPUTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3UPUSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7RxMTP3UPUEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3UPUInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxMTP3UPUEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3UPUVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxMTP3UPUEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3UPUTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxMTP3UPUEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscarded table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP3MSUDiscardedTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of discarded MTP3 MSU's per SS7 MTP3 node"
|
|
::= {acPMSS7SignalingNodes 7}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscarded table entry
|
|
-- ****************************************
|
|
acPMSS7MTP3MSUDiscardedEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP3MSUDiscardedEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP3MSUDiscardedSN,acPMSS7MTP3MSUDiscardedInterval}
|
|
::= {acPMSS7MTP3MSUDiscardedTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscarded TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP3MSUDiscardedEntry ::= SEQUENCE {
|
|
acPMSS7MTP3MSUDiscardedSN Unsigned32,
|
|
acPMSS7MTP3MSUDiscardedInterval Unsigned32,
|
|
acPMSS7MTP3MSUDiscardedVal Counter32,
|
|
acPMSS7MTP3MSUDiscardedTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7MTP3MSUDiscardedEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP3MSUDiscardedEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP3MSUDiscardedEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP3MSUDiscardedEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscardedRtDataErr table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP3MSUDiscardedRtDataErrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP3MSUDiscardedRtDataErrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP3 Msu's discarded Due to Routing Data error per SS7 MTP3 node - Q.752 5.5"
|
|
::= {acPMSS7SignalingNodes 8}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscardedRtDataErr table entry
|
|
-- ****************************************
|
|
acPMSS7MTP3MSUDiscardedRtDataErrEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP3MSUDiscardedRtDataErrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP3MSUDiscardedRtDataErrSN,acPMSS7MTP3MSUDiscardedRtDataErrInterval}
|
|
::= {acPMSS7MTP3MSUDiscardedRtDataErrTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP3MSUDiscardedRtDataErr TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP3MSUDiscardedRtDataErrEntry ::= SEQUENCE {
|
|
acPMSS7MTP3MSUDiscardedRtDataErrSN Unsigned32,
|
|
acPMSS7MTP3MSUDiscardedRtDataErrInterval Unsigned32,
|
|
acPMSS7MTP3MSUDiscardedRtDataErrVal Counter32,
|
|
acPMSS7MTP3MSUDiscardedRtDataErrTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedRtDataErrSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedRtDataErrInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedRtDataErrVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP3MSUDiscardedRtDataErrTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP3MSUDiscardedRtDataErrEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3TFCMsg table declaration
|
|
-- ****************************************
|
|
acPMSS7RxMTP3TFCMsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7RxMTP3TFCMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP3 TFC messages received per SS7 MTP3 node "
|
|
::= {acPMSS7SignalingNodes 9}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3TFCMsg table entry
|
|
-- ****************************************
|
|
acPMSS7RxMTP3TFCMsgEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7RxMTP3TFCMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7RxMTP3TFCMsgSN,acPMSS7RxMTP3TFCMsgInterval}
|
|
::= {acPMSS7RxMTP3TFCMsgTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7RxMTP3TFCMsg TABLE
|
|
-- ****************************************
|
|
AcPMSS7RxMTP3TFCMsgEntry ::= SEQUENCE {
|
|
acPMSS7RxMTP3TFCMsgSN Unsigned32,
|
|
acPMSS7RxMTP3TFCMsgInterval Unsigned32,
|
|
acPMSS7RxMTP3TFCMsgVal Counter32,
|
|
acPMSS7RxMTP3TFCMsgTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3TFCMsgSN OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"SN number.
|
|
0 is the first SN."
|
|
::= {acPMSS7RxMTP3TFCMsgEntry 1}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3TFCMsgInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7RxMTP3TFCMsgEntry 2}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3TFCMsgVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7RxMTP3TFCMsgEntry 3}
|
|
|
|
|
|
|
|
acPMSS7RxMTP3TFCMsgTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7RxMTP3TFCMsgEntry 4}
|
|
|
|
|
|
|
|
acPMSS7MPT2Timers OBJECT IDENTIFIER ::= {acPMSS7Data 61}
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T1Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T1ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T1ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T1 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T1Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T1ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T1ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T1ExpiryLink,acPMSS7MTP2T1ExpiryInterval}
|
|
::= {acPMSS7MTP2T1ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T1Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T1ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T1ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T1ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T1ExpiryVal Counter32,
|
|
acPMSS7MTP2T1ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T1ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T1ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T1ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T1ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T1ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T1ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T1ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T1ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T2Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T2ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T2ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T2 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 2}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T2Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T2ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T2ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T2ExpiryLink,acPMSS7MTP2T2ExpiryInterval}
|
|
::= {acPMSS7MTP2T2ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T2Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T2ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T2ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T2ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T2ExpiryVal Counter32,
|
|
acPMSS7MTP2T2ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T2ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T2ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T2ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T2ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T2ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T2ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T2ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T2ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T3Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T3ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T3ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T3 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 3}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T3Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T3ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T3ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T3ExpiryLink,acPMSS7MTP2T3ExpiryInterval}
|
|
::= {acPMSS7MTP2T3ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T3Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T3ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T3ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T3ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T3ExpiryVal Counter32,
|
|
acPMSS7MTP2T3ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T3ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T3ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T3ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T3ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T3ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T3ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T3ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T3ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T4Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T4ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T4ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T4 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T4Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T4ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T4ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T4ExpiryLink,acPMSS7MTP2T4ExpiryInterval}
|
|
::= {acPMSS7MTP2T4ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T4Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T4ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T4ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T4ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T4ExpiryVal Counter32,
|
|
acPMSS7MTP2T4ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T4ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T4ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T4ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T4ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T4ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T4ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T4ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T4ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T5Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T5ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T5ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T5 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 5}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T5Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T5ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T5ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T5ExpiryLink,acPMSS7MTP2T5ExpiryInterval}
|
|
::= {acPMSS7MTP2T5ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T5Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T5ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T5ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T5ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T5ExpiryVal Counter32,
|
|
acPMSS7MTP2T5ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T5ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T5ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T5ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T5ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T5ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T5ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T5ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T5ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T6Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T6ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T6ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T6 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 6}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T6Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T6ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T6ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T6ExpiryLink,acPMSS7MTP2T6ExpiryInterval}
|
|
::= {acPMSS7MTP2T6ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T6Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T6ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T6ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T6ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T6ExpiryVal Counter32,
|
|
acPMSS7MTP2T6ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T6ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T6ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T6ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T6ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T6ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T6ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T6ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T6ExpiryEntry 4}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T7Expiry table declaration
|
|
-- ****************************************
|
|
acPMSS7MTP2T7ExpiryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AcPMSS7MTP2T7ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Number of MTP2 T7 expiry per SS7 link"
|
|
::= {acPMSS7MPT2Timers 7}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T7Expiry table entry
|
|
-- ****************************************
|
|
acPMSS7MTP2T7ExpiryEntry OBJECT-TYPE
|
|
SYNTAX AcPMSS7MTP2T7ExpiryEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
""
|
|
INDEX {acPMSS7MTP2T7ExpiryLink,acPMSS7MTP2T7ExpiryInterval}
|
|
::= {acPMSS7MTP2T7ExpiryTable 1}
|
|
|
|
|
|
|
|
-- ****************************************
|
|
-- acPMSS7MTP2T7Expiry TABLE
|
|
-- ****************************************
|
|
AcPMSS7MTP2T7ExpiryEntry ::= SEQUENCE {
|
|
acPMSS7MTP2T7ExpiryLink Unsigned32,
|
|
acPMSS7MTP2T7ExpiryInterval Unsigned32,
|
|
acPMSS7MTP2T7ExpiryVal Counter32,
|
|
acPMSS7MTP2T7ExpiryTotal Integer32
|
|
}
|
|
|
|
|
|
|
|
acPMSS7MTP2T7ExpiryLink OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Link number.
|
|
0 is the first link."
|
|
::= {acPMSS7MTP2T7ExpiryEntry 1}
|
|
|
|
|
|
|
|
acPMSS7MTP2T7ExpiryInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..2)
|
|
MAX-ACCESS not-accessible
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Interval index.
|
|
0 - current period (incomplete monitoring - mid period).
|
|
1 - Last full period.
|
|
2 - One before last."
|
|
::= {acPMSS7MTP2T7ExpiryEntry 2}
|
|
|
|
|
|
|
|
acPMSS7MTP2T7ExpiryVal OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Value of gauge or counter."
|
|
::= {acPMSS7MTP2T7ExpiryEntry 3}
|
|
|
|
|
|
|
|
acPMSS7MTP2T7ExpiryTotal OBJECT-TYPE
|
|
SYNTAX Integer32 (-1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Total since last reset."
|
|
::= {acPMSS7MTP2T7ExpiryEntry 4}
|
|
|
|
|
|
|
|
|
|
|
|
END
|