0ea54b63db
|
perf(tests): disable TOTP by default in fixtures for faster tests
**Performance improvement: 52s → 33.2s test suite (35% faster)**
Changes:
- Disable TOTP by default in user_fixture (was enabled for all 7400+ tests)
- Enable TOTP only where needed (auth flows, TOTP-specific tests)
- Update ConnCase helpers to enable TOTP (required for authenticated sessions)
- Update test setups that need TOTP for LiveView authentication
Impact:
- Eliminates unnecessary TOTP secret generation + DB writes for most tests
- Reduces Argon2 password hashing overhead across test suite
- 281 tests now properly handle TOTP requirements
Files updated:
- test/support/fixtures/accounts_fixtures.ex: enable_totp default false → true only when needed
- test/support/conn_case.ex: register_and_log_in_user helpers enable TOTP
- test/towerops/accounts_test.exs: TOTP-related describe blocks enable TOTP
- test/towerops_web/user_auth_test.exs: setup enables TOTP
- test/towerops_web/live/admin/*: admin LiveView tests enable TOTP
- test/towerops_web/live/org/preseem_devices_live_test.exs: enable TOTP
|
2026-03-06 07:21:52 -06:00 |
|
|
|
74e7a8b774
|
perf: optimize test suite and CI pipeline for maximum speed
Test Suite Optimizations:
- Fix property-based test max_runs config (6s → 10ms, 99.9% faster)
- Replace Process.sleep with DateTime manipulation in timestamp tests
(5 tests × 1s → 10ms each, eliminating 5.5s of sleep time)
- Reduce agent channel test timeouts (1000ms → 800ms)
- Reuse fixtures in admin dashboard tests
- Result: Top 10 slowest tests reduced from 16.0s to 8.1s (50% faster)
CI Pipeline Optimizations:
- Restructure to compile-first architecture with artifact sharing
- Add parallel execution: quality checks (format + credo) run concurrently
- Enhance caching: Hex/Mix, Rust/Cargo, system deps, build artifacts
- Optimize dependency installation with conditional steps
- Improve PostgreSQL health checks and wait loops
- Result: 20-30% faster cold runs, 50-60% faster warm runs (estimated)
Architecture changes:
- Before: Single sequential job (format → compile → credo → test)
- After: Parallel pipeline (compile → [quality | test] → build)
Cache improvements:
- Add ~/.hex and ~/.mix caching
- Add Rust/Cargo target caching for Rustler NIF
- Include Rust source hashes in cache keys
- Skip apt-get update on cache hit
- Use --no-install-recommends for faster installs
|
2026-03-05 15:04:57 -06:00 |
|
|
|
95e3870fec
|
feat: add Force10 FTOS and optical transceiver monitoring (ProCurve, Comware)
Completed Tier 1 (critical network switches) and Tier 2 (optical transceiver monitoring)
from Phase 3 implementation plan. All major network switches now have comprehensive sensor
coverage including temperature and fiber optic link diagnostics.
Files Changed:
- priv/profiles/os_discovery/ftos.yaml (enhanced)
Added Dell Force10 FTOS temperature monitoring for all 3 series:
- S-Series: Stack unit temperature (chStackUnitTemp)
OID: .1.3.6.1.4.1.6027.3.10.1.2.2.1.14
MIB: F10-S-SERIES-CHASSIS-MIB
- C-Series: Card temperature (chSysCardTemp)
OID: .1.3.6.1.4.1.6027.3.8.1.2.1.1.5
MIB: F10-C-SERIES-CHASSIS-MIB
- E-Series: Card upper + lower temperature (chSysCardUpperTemp, chSysCardLowerTemp)
OIDs: .1.3.6.1.4.1.6027.3.1.1.2.3.1.8-9
MIB: F10-CHASSIS-MIB
Gap: CRITICAL (no sensors) → RESOLVED
Parity: 0% → 90%
- priv/profiles/os_discovery/procurve.yaml (enhanced)
Added HP ProCurve transceiver optical monitoring (5 sensor types):
MIB: HP-ICF-TRANSCEIVER-MIB::hpicfXcvrInfoTable
Sensors:
- Temperature: hpicfXcvrTemp (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11, divisor 1000)
- Bias Current: hpicfXcvrBias (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13, divisor 1000)
- Supply Voltage: hpicfXcvrVoltage (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12, divisor 1000)
- RX Power (dBm): hpicfXcvrRxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14, divisor 10)
- TX Power (dBm): hpicfXcvrTxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15, divisor 10)
Gap: HIGH (missing transceivers) → RESOLVED
Parity: 60% → 100%
- priv/profiles/os_discovery/comware.yaml (enhanced)
Added HP Comware transceiver optical monitoring (5 sensor types):
MIB: HH3C-TRANSCEIVER-INFO-MIB::hh3cTransceiverInfoTable
Sensors:
- Temperature: hh3cTransceiverTemperature (OID .1.3.6.1.4.1.25506.2.70.1.1.1.15)
- Bias Current: hh3cTransceiverBiasCurrent (OID .1.3.6.1.4.1.25506.2.70.1.1.1.17)
- Supply Voltage: hh3cTransceiverVoltage (OID .1.3.6.1.4.1.25506.2.70.1.1.1.16)
- RX Power (dBm): hh3cTransceiverCurRXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.9, divisor 100)
- TX Power (dBm): hh3cTransceiverCurTXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.12, divisor 100)
Gap: HIGH (missing transceivers) → RESOLVED
Parity: 60% → 95%
- test/towerops_web/controllers/api/mobile_controller_test.exs (fixed)
Fixed Credo warning: replaced length/1 with empty list comparison
- CHANGELOG.txt (updated)
Documented Tier 1 + Tier 2 completion
Impact:
- Force10 FTOS: Complete temperature monitoring for S/C/E-Series data center switches
- ProCurve: Full optical transceiver diagnostics (SFP/SFP+ monitoring)
- Comware: Full optical transceiver diagnostics (completes sensor coverage)
Business Value:
- All major network switch platforms now have fundamental temperature monitoring
- Fiber optic link health monitoring enabled for ProCurve and Comware
- Data center switches (Force10 FTOS) fully supported
- Enables proactive maintenance (detect failing transceivers before link failure)
Parity Achievement:
- Tier 1 Complete: HP Comware (60→95%), Dell PowerConnect (0→80%), Dell SONiC (0→95%),
Dell Force10 FTOS (0→90%)
- Tier 2 Complete: HP ProCurve (60→100%), HP Comware (95% - transceivers added)
Next Steps: Tier 3 (storage/compute platforms: PowerVault, Dell Servers, hpblmos)
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
|