Commit graph

7 commits

Author SHA1 Message Date
e6054129b2
remote agent/cloud improvements 2026-01-24 09:16:41 -06:00
96fc488023
sanitize snmp data and fix some cpu things 2026-01-22 16:53:01 -06:00
1c400259fc
fix: use microsecond precision for ICMP latency measurements
- Changed ping module to use microsecond timer resolution instead of millisecond
- Prevents 0ms readings for very fast pings (localhost, local network)
- Updated response_time_ms to float type to store decimal precision
- Migration converts existing integer values to float
2026-01-18 12:52:29 -06:00
b6f4946385
moduledocs 2026-01-17 15:08:49 -06:00
a810e75fc4
rename equipment to device 2026-01-17 14:48:46 -06:00
d88cf9dddc
mix format 2025-12-21 17:17:35 -06:00
d431db37bb
What Was Built
Monitoring Infrastructure:
  - lib/towerops/monitoring/ping.ex - OS-agnostic ping functionality that works on macOS, Linux, and Windows
  - lib/towerops/monitoring/equipment_monitor.ex - GenServer that monitors individual equipment at configurable intervals
  - lib/towerops/monitoring/supervisor.ex - DynamicSupervisor with Registry for managing monitor workers
  - lib/towerops/monitoring.ex - Context for creating and querying monitoring checks

  Database:
  - monitoring_checks table stores historical ping results with status, response time, and timestamps
  - Indexed on (equipment_id, checked_at) for efficient querying

  Real-Time Updates:
  - PubSub broadcasting on equipment:#{id} topic when status changes
  - Equipment show page subscribes to updates and refreshes automatically
  - Manual "Check Now" button to trigger immediate checks

  Application Integration:
  - Monitoring.Supervisor added to application supervision tree
  - All monitored equipment starts monitoring automatically on app startup
  - Recent checks displayed in Equipment show page

  How It Works

  1. On application start, a monitor GenServer is spawned for each equipment with monitoring_enabled: true
  2. Each monitor pings its equipment at the configured interval (default 5 minutes)
  3. Results are saved to monitoring_checks table
  4. Equipment status is updated if it changes (up ↔ down)
  5. Status changes are broadcast via PubSub to all connected LiveViews
  6. The Equipment show page updates in real-time when status changes
2025-12-21 16:52:23 -06:00