Commit graph

4 commits

Author SHA1 Message Date
810dafbf5e remove all fixed critical items from bugs.md, fix flaky MIB cache test 2026-05-12 10:35:52 -05:00
22f5c3ed63 test: lift coverage to 78.42% and link Ansible collection in docs
- Add Codeberg Ansible collection link to API/GraphQL docs and Terraform guide
- Un-skip the previously-disabled DevicePollerWorker tests that still pass
- Expand MibController, CnMaestro.Sync, CheckWorker, ActivityFeed,
  MobileController, JobCleanupTask tests
- New UploadMibs Mix task test covering arg validation and upload paths
- Set :mib_dir in test config so MibController upload/delete flows can
  exercise the real on-disk paths against a writable tmp directory
2026-05-07 16:48:53 -05:00
2e399953c1 test: expand coverage across resolvers, vendors, controllers, workers
Add focused tests across many modules to push overall coverage from
75.45% to ~77%.

New test files:
- test/towerops/snmp/topology_test.exs
- test/towerops/vault_test.exs
- test/towerops/workers/check_worker_test.exs
- test/towerops_web/graphql/resolvers/happy_path_test.exs
- test/towerops_web/graphql/schema_test.exs
- test/towerops_web/live/reports_live_test.exs

Expanded existing tests for: Airos vendor, ProfileWatcher, StormDetector,
LLDP, GpsSync, MikrotikBackupWorker, AdminController, MibController,
MobileController, GeoipController, OnboardingLive, UserResetPasswordLive,
SessionManager, Telemetry, CoverageLive.Show.

Also fix a pre-existing dead test in ApplicationSettingTest where the
schema default for value_type made the 'invalid without value_type' test
unreachable.
2026-05-07 14:23:58 -05:00
95e3870fec
feat: add Force10 FTOS and optical transceiver monitoring (ProCurve, Comware)
Completed Tier 1 (critical network switches) and Tier 2 (optical transceiver monitoring)
from Phase 3 implementation plan. All major network switches now have comprehensive sensor
coverage including temperature and fiber optic link diagnostics.

Files Changed:
- priv/profiles/os_discovery/ftos.yaml (enhanced)
  Added Dell Force10 FTOS temperature monitoring for all 3 series:
  - S-Series: Stack unit temperature (chStackUnitTemp)
    OID: .1.3.6.1.4.1.6027.3.10.1.2.2.1.14
    MIB: F10-S-SERIES-CHASSIS-MIB
  - C-Series: Card temperature (chSysCardTemp)
    OID: .1.3.6.1.4.1.6027.3.8.1.2.1.1.5
    MIB: F10-C-SERIES-CHASSIS-MIB
  - E-Series: Card upper + lower temperature (chSysCardUpperTemp, chSysCardLowerTemp)
    OIDs: .1.3.6.1.4.1.6027.3.1.1.2.3.1.8-9
    MIB: F10-CHASSIS-MIB
  Gap: CRITICAL (no sensors) → RESOLVED
  Parity: 0% → 90%

- priv/profiles/os_discovery/procurve.yaml (enhanced)
  Added HP ProCurve transceiver optical monitoring (5 sensor types):
  MIB: HP-ICF-TRANSCEIVER-MIB::hpicfXcvrInfoTable
  Sensors:
    - Temperature: hpicfXcvrTemp (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11, divisor 1000)
    - Bias Current: hpicfXcvrBias (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13, divisor 1000)
    - Supply Voltage: hpicfXcvrVoltage (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12, divisor 1000)
    - RX Power (dBm): hpicfXcvrRxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14, divisor 10)
    - TX Power (dBm): hpicfXcvrTxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15, divisor 10)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 100%

- priv/profiles/os_discovery/comware.yaml (enhanced)
  Added HP Comware transceiver optical monitoring (5 sensor types):
  MIB: HH3C-TRANSCEIVER-INFO-MIB::hh3cTransceiverInfoTable
  Sensors:
    - Temperature: hh3cTransceiverTemperature (OID .1.3.6.1.4.1.25506.2.70.1.1.1.15)
    - Bias Current: hh3cTransceiverBiasCurrent (OID .1.3.6.1.4.1.25506.2.70.1.1.1.17)
    - Supply Voltage: hh3cTransceiverVoltage (OID .1.3.6.1.4.1.25506.2.70.1.1.1.16)
    - RX Power (dBm): hh3cTransceiverCurRXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.9, divisor 100)
    - TX Power (dBm): hh3cTransceiverCurTXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.12, divisor 100)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 95%

- test/towerops_web/controllers/api/mobile_controller_test.exs (fixed)
  Fixed Credo warning: replaced length/1 with empty list comparison

- CHANGELOG.txt (updated)
  Documented Tier 1 + Tier 2 completion

Impact:
- Force10 FTOS: Complete temperature monitoring for S/C/E-Series data center switches
- ProCurve: Full optical transceiver diagnostics (SFP/SFP+ monitoring)
- Comware: Full optical transceiver diagnostics (completes sensor coverage)

Business Value:
- All major network switch platforms now have fundamental temperature monitoring
- Fiber optic link health monitoring enabled for ProCurve and Comware
- Data center switches (Force10 FTOS) fully supported
- Enables proactive maintenance (detect failing transceivers before link failure)

Parity Achievement:
- Tier 1 Complete: HP Comware (60→95%), Dell PowerConnect (0→80%), Dell SONiC (0→95%),
  Dell Force10 FTOS (0→90%)
- Tier 2 Complete: HP ProCurve (60→100%), HP Comware (95% - transceivers added)

Next Steps: Tier 3 (storage/compute platforms: PowerVault, Dell Servers, hpblmos)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-12 08:19:12 -06:00