Commit graph

5 commits

Author SHA1 Message Date
9c5b4096f9
discovery working 2026-01-25 14:48:57 -06:00
d0946c3cd0
refactor: simplify job architecture from Oban coordinators to direct workers
Removes unnecessary two-layer architecture (Oban Coordinator → GenServer)
in favor of direct Oban workers that perform the actual work.

Changes:
- Replace DevicePollerCoordinator + PollerWorker with DevicePollerWorker
- Replace DeviceMonitorCoordinator + DeviceMonitor with DeviceMonitorWorker
- Simplify Monitoring.Supervisor (removed Registries, DynamicSupervisors)
- Remove all Exq dependencies (workers, supervisor, mix deps)
- Convert DiscoveryWorker from Exq to Oban pattern
- Update Devices context to auto-start/stop monitoring and polling
- Update all LiveView callers to use new Oban enqueue pattern
- Fix all tests to use Oban.Job struct instead of raw IDs

Benefits:
- Simpler codebase (~850 lines removed)
- Better reliability (Oban handles retries, failures)
- Lower memory (no persistent GenServers)
- Better observability (work visible in Oban dashboard)
- Cluster-wide coordination via PostgreSQL
- Extensive PubSub usage for real-time events

Files deleted:
- lib/towerops/workers/device_monitor_coordinator.ex
- lib/towerops/workers/device_poller_coordinator.ex
- lib/towerops/snmp/poller_worker.ex
- lib/towerops/monitoring/device_monitor.ex
- lib/towerops/workers/monitor_worker.ex
- lib/towerops/workers/poll_worker.ex
- lib/towerops/exq_supervisor.ex
- All related test files

Files created:
- lib/towerops/workers/device_poller_worker.ex
- lib/towerops/workers/device_monitor_worker.ex

All 3,686 tests passing.
2026-01-24 16:36:57 -06:00
0a4482f974
feat: add 5 new vendor modules and fix dialyzer issues
Vendor modules added:
- Aviat (WTM microwave radios)
- Aruba (wireless controllers and APs)
- CiscoWLC (Cisco wireless LAN controllers)
- Teltonika (RUTOS LTE routers)
- Sub10 (mmWave backhaul radios)

Dialyzer fixes:
- Fix unknown type Devices.t/0 in alert.ex and device.ex
- Fix unmatched_return warnings across multiple files
- Add :exq to PLT for Exq function detection
- Remove dead code in base.ex, dynamic.ex, vendor.ex
- Fix Device.t() type spec to allow nil name field

Tests: 1437 tests, 0 failures
Dialyzer: 0 errors
Credo: no issues
2026-01-22 09:34:50 -06:00
94311a48aa
discovery fix and favicon 2026-01-18 13:47:19 -06:00
a810e75fc4
rename equipment to device 2026-01-17 14:48:46 -06:00
Renamed from lib/towerops_web/live/equipment_live/index.ex (Browse further)