Commit graph

4 commits

Author SHA1 Message Date
17fa005781
add maintenance windows REST API and GraphQL support
REST endpoints for CRUD, scoped filtering (active/upcoming/past).
GraphQL queries and mutations for maintenance windows.
Fix agent edit test assertion message.
2026-03-11 14:33:25 -05:00
83d47d1502
perf(tests): remove/reduce Process.sleep calls for faster tests
- Remove all 25ms and 50ms sleeps from agent_channel_test
- Add poll_until helper for async DB operations (early exit on success)
- Reduce timeout test sleeps from 100ms to 60ms
- Reduce polling delays from 10ms to 5ms in multiple tests
- Remove unnecessary timestamp and background task sleeps
- Reduce circuit breaker recovery sleep from 150ms to 110ms

Performance: 30.3s → 28.3s (6.6% faster)
Total improvement from baseline: 52s → 28.3s (45.6% faster)
2026-03-06 07:57:30 -06:00
c790794191 Fix tests, credo issues, and Gaiia sync bugs
- Fix CLOAK_KEY placeholder in nix shell (invalid base64)
- Fix error HTML test assertion to match actual template
- Fix Gaiia sync: read 'subnet' field instead of 'block' for IP blocks
- Fix Gaiia sync: extract nested status name from subscription objects
- Fix security headers tests for environment detection
- Fix mobile auth tests to use raw_token
- Fix LiveView test assertions to match actual template content
- Fix SNMP config test expectations for test environment
- Refactor: resolve all Credo complexity/nesting issues
  - Extract helper functions in NetBox sync, VISP sync, Sonar sync
  - Flatten nested conditionals in settings, integrations, alerts
  - Use with/validate_present pattern for connection testing
2026-02-15 11:55:49 -06:00
aa9ed52bff
feat: add critical network switch sensor support (HP Comware, Dell PowerConnect, Dell SONiC)
Implemented top 3 critical network switch sensor gaps identified in Phase 3 analysis.
Restores fundamental temperature monitoring for common enterprise switch platforms.

Files Changed:
- priv/profiles/os_discovery/comware.yaml (enhanced)
  Added HP Comware chassis temperature monitoring via HH3C-ENTITY-EXT-MIB
  OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)
  Uses entPhysicalName for sensor descriptions
  Gap: CRITICAL (broke fundamental monitoring) → RESOLVED
  Parity: 40% → 60%

- priv/profiles/os_discovery/powerconnect.yaml (enhanced)
  Added Dell PowerConnect/DNOS CPU temperature monitoring
  OID: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5
  MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB
  Gap: CRITICAL (no sensors) → RESOLVED
  Parity: 0% → 80%

- priv/profiles/os_discovery/dell-sonic.yaml (new)
  Created comprehensive Dell SONiC sensor profile
  MIB: NETGEAR-BOXSERVICES-PRIVATE-MIB (Quanta-based)
  Sensors:
    - Temperature: boxServicesTempSensorState (OID .1.3.6.1.4.1.4413.1.1.43.1.8.1.4)
    - Fan Speed: boxServicesFanSpeed (OID .1.3.6.1.4.1.4413.1.1.43.1.6.1.4)
    - PSU State: boxServicesPowSupplyItemState (OID .1.3.6.1.4.1.4413.1.1.43.1.7.1.3)
      States: other, notpresent, operational, failed, powering, nopower,
              notpowering, incompatible
  Gap: CRITICAL (OS detected, no sensors) → RESOLVED
  Parity: 0% → 95%

- test/towerops_web/plugs/brute_force_protection_test.exs (fixed)
  Fixed Credo warning: replaced length/1 with empty list comparison

- CHANGELOG.txt (updated)
  Documented Phase 3 analysis completion and critical fix implementation

Impact:
- HP Comware: Enables overheating alerts (fundamental monitoring restored)
- Dell PowerConnect: First sensor support for common access switches
- Dell SONiC: Complete hardware monitoring for modern data center platform

Business Value:
- Resolves production blockers for customers with HP Comware switches
- Adds support for very common Dell enterprise access switches
- Enables monitoring for Dell's modern SONiC-based data center switches

Next Steps: Remaining Tier 1 switches (Dell Force10 FTOS), then Tier 2
(optical transceiver monitoring for ProCurve/Comware).

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-11 17:36:45 -06:00