Commit graph

10 commits

Author SHA1 Message Date
cd19e6626c fix(tests): replace Process.sleep with event-driven sync patterns
Replaced unbounded Process.sleep calls across the test suite with
event-driven alternatives: :sys.get_state sync barriers, assert_receive
with bounded timeouts, and Process.send_after + assert_receive.

Largest improvements:
- storm_detector_test: 120-150ms sleeps removed, uses assert_receive
- deferred_discovery_test: 500ms -> 50ms (timeout test simulation)
- event_logger_test: polling loop replaced with :sys.get_state barrier
- tcp_executor_test: 2000ms sleep replaced with bounded recv timeout
- rate_limit_test: sleeps replaced with send_after + assert_receive
- Various 5-50ms sleeps removed from live_view tests
- Unused require Logger removed from 2 test files
2026-06-02 15:16:53 -05:00
0c7d195e52
chore: remove backup files from sed operations 2026-03-06 07:57:30 -06:00
83d47d1502
perf(tests): remove/reduce Process.sleep calls for faster tests
- Remove all 25ms and 50ms sleeps from agent_channel_test
- Add poll_until helper for async DB operations (early exit on success)
- Reduce timeout test sleeps from 100ms to 60ms
- Reduce polling delays from 10ms to 5ms in multiple tests
- Remove unnecessary timestamp and background task sleeps
- Reduce circuit breaker recovery sleep from 150ms to 110ms

Performance: 30.3s → 28.3s (6.6% faster)
Total improvement from baseline: 52s → 28.3s (45.6% faster)
2026-03-06 07:57:30 -06:00
95e3870fec
feat: add Force10 FTOS and optical transceiver monitoring (ProCurve, Comware)
Completed Tier 1 (critical network switches) and Tier 2 (optical transceiver monitoring)
from Phase 3 implementation plan. All major network switches now have comprehensive sensor
coverage including temperature and fiber optic link diagnostics.

Files Changed:
- priv/profiles/os_discovery/ftos.yaml (enhanced)
  Added Dell Force10 FTOS temperature monitoring for all 3 series:
  - S-Series: Stack unit temperature (chStackUnitTemp)
    OID: .1.3.6.1.4.1.6027.3.10.1.2.2.1.14
    MIB: F10-S-SERIES-CHASSIS-MIB
  - C-Series: Card temperature (chSysCardTemp)
    OID: .1.3.6.1.4.1.6027.3.8.1.2.1.1.5
    MIB: F10-C-SERIES-CHASSIS-MIB
  - E-Series: Card upper + lower temperature (chSysCardUpperTemp, chSysCardLowerTemp)
    OIDs: .1.3.6.1.4.1.6027.3.1.1.2.3.1.8-9
    MIB: F10-CHASSIS-MIB
  Gap: CRITICAL (no sensors) → RESOLVED
  Parity: 0% → 90%

- priv/profiles/os_discovery/procurve.yaml (enhanced)
  Added HP ProCurve transceiver optical monitoring (5 sensor types):
  MIB: HP-ICF-TRANSCEIVER-MIB::hpicfXcvrInfoTable
  Sensors:
    - Temperature: hpicfXcvrTemp (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11, divisor 1000)
    - Bias Current: hpicfXcvrBias (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13, divisor 1000)
    - Supply Voltage: hpicfXcvrVoltage (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12, divisor 1000)
    - RX Power (dBm): hpicfXcvrRxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14, divisor 10)
    - TX Power (dBm): hpicfXcvrTxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15, divisor 10)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 100%

- priv/profiles/os_discovery/comware.yaml (enhanced)
  Added HP Comware transceiver optical monitoring (5 sensor types):
  MIB: HH3C-TRANSCEIVER-INFO-MIB::hh3cTransceiverInfoTable
  Sensors:
    - Temperature: hh3cTransceiverTemperature (OID .1.3.6.1.4.1.25506.2.70.1.1.1.15)
    - Bias Current: hh3cTransceiverBiasCurrent (OID .1.3.6.1.4.1.25506.2.70.1.1.1.17)
    - Supply Voltage: hh3cTransceiverVoltage (OID .1.3.6.1.4.1.25506.2.70.1.1.1.16)
    - RX Power (dBm): hh3cTransceiverCurRXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.9, divisor 100)
    - TX Power (dBm): hh3cTransceiverCurTXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.12, divisor 100)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 95%

- test/towerops_web/controllers/api/mobile_controller_test.exs (fixed)
  Fixed Credo warning: replaced length/1 with empty list comparison

- CHANGELOG.txt (updated)
  Documented Tier 1 + Tier 2 completion

Impact:
- Force10 FTOS: Complete temperature monitoring for S/C/E-Series data center switches
- ProCurve: Full optical transceiver diagnostics (SFP/SFP+ monitoring)
- Comware: Full optical transceiver diagnostics (completes sensor coverage)

Business Value:
- All major network switch platforms now have fundamental temperature monitoring
- Fiber optic link health monitoring enabled for ProCurve and Comware
- Data center switches (Force10 FTOS) fully supported
- Enables proactive maintenance (detect failing transceivers before link failure)

Parity Achievement:
- Tier 1 Complete: HP Comware (60→95%), Dell PowerConnect (0→80%), Dell SONiC (0→95%),
  Dell Force10 FTOS (0→90%)
- Tier 2 Complete: HP ProCurve (60→100%), HP Comware (95% - transceivers added)

Next Steps: Tier 3 (storage/compute platforms: PowerVault, Dell Servers, hpblmos)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-12 08:19:12 -06:00
2911a3c17d
test fixes 2026-02-09 15:30:52 -06:00
8382b5df6a
make devices site optional and many test fix 2026-02-04 15:05:42 -06:00
421f2e05f3
faster tests 2026-01-27 09:30:18 -06:00
77d4b25da7
test cleanup 2026-01-19 13:29:38 -06:00
d87461ba14
feat: add monitoring mode tab selector (SNMP & ICMP vs ICMP Only)
- Add tab selector in Monitoring Configuration section for choosing monitoring mode
- SNMP & ICMP mode: enables ICMP pings + SNMP discovery (default)
- ICMP Only mode: enables only ICMP ping monitoring, hides SNMP fields
- Monitoring mode controls snmp_enabled field automatically on save
- Test SNMP Connection button shows informational message when agent is configured
  (agents handle SNMP testing during their polling cycle)
- Update all tests to use tab selector instead of setting snmp_enabled directly
- All 818 tests passing with no Credo warnings
2026-01-17 16:10:59 -06:00
a810e75fc4
rename equipment to device 2026-01-17 14:48:46 -06:00