Commit graph

5 commits

Author SHA1 Message Date
38619f2b88 test: lift coverage to 87.14% via targeted branch tests
Adds tests across five files:
- Towerops.Monitoring.CheckQuery (full coverage of all composable filter
  fragments via inspect+Repo.all)
- ToweropsWeb.Admin.SecurityLive.Index change_filter event for both
  permanent and temporary filter values
- Towerops.Agents.AgentCache cleanup_expired handle_info path that
  prunes stale device entries while preserving :global_default
- ToweropsWeb.Api.V1.AgentReleaseWebhookController happy path
  (notified/skipped/version) and error path (Codeberg 503)
- ToweropsWeb.DeviceLive.Index reorder_device / reorder_site
  unauthorized branches via cross-org device/site fixtures
2026-05-09 11:44:25 -05:00
aa7fc830e5 test: refactor LiveView tests to use HTML-aware element/form helpers
Apply patterns from testingliveview.com — replace render_click/submit/change
event-name calls with element/form-targeted equivalents that validate the
actual DOM wiring, not just handler logic. Adds stable test selectors
(id="...") to interactive elements across 10 LiveView templates.

Surfaces (and fixes) several real issues that the bypass-style tests masked:
- Removes dead regenerate_token handler in agent_live/index.ex (no UI ever
  triggered it) and its corresponding test.
- Removes dead refresh_topology test in network_map_live_test (event was
  referenced only in the test — no handler, no button, no JS anywhere).
- Corrects "shows notification tab with add device modal" — modal lives on
  the security tab; original test mounted ?tab=notifications and only
  worked because direct event calls bypassed tab gating.
- Corrects form input shape mismatches in agent_live/index_test that the
  handler's defensive case clauses had been masking.
- Expands setup data for org/settings_live_test (snmp_community,
  default_agent_token_id, multi-org membership) so the gated buttons
  actually render.

11 direct render_click/submit/change calls remain — all intentional,
documented server-side guard tests (tampered POSTs, race conditions,
defensive idempotent handlers).

Full LiveView test suite: 1300 tests, 0 failures.
2026-04-29 11:14:20 -05:00
0ea54b63db
perf(tests): disable TOTP by default in fixtures for faster tests
**Performance improvement: 52s → 33.2s test suite (35% faster)**

Changes:
- Disable TOTP by default in user_fixture (was enabled for all 7400+ tests)
- Enable TOTP only where needed (auth flows, TOTP-specific tests)
- Update ConnCase helpers to enable TOTP (required for authenticated sessions)
- Update test setups that need TOTP for LiveView authentication

Impact:
- Eliminates unnecessary TOTP secret generation + DB writes for most tests
- Reduces Argon2 password hashing overhead across test suite
- 281 tests now properly handle TOTP requirements

Files updated:
- test/support/fixtures/accounts_fixtures.ex: enable_totp default false → true only when needed
- test/support/conn_case.ex: register_and_log_in_user helpers enable TOTP
- test/towerops/accounts_test.exs: TOTP-related describe blocks enable TOTP
- test/towerops_web/user_auth_test.exs: setup enables TOTP
- test/towerops_web/live/admin/*: admin LiveView tests enable TOTP
- test/towerops_web/live/org/preseem_devices_live_test.exs: enable TOTP
2026-03-06 07:21:52 -06:00
95e3870fec
feat: add Force10 FTOS and optical transceiver monitoring (ProCurve, Comware)
Completed Tier 1 (critical network switches) and Tier 2 (optical transceiver monitoring)
from Phase 3 implementation plan. All major network switches now have comprehensive sensor
coverage including temperature and fiber optic link diagnostics.

Files Changed:
- priv/profiles/os_discovery/ftos.yaml (enhanced)
  Added Dell Force10 FTOS temperature monitoring for all 3 series:
  - S-Series: Stack unit temperature (chStackUnitTemp)
    OID: .1.3.6.1.4.1.6027.3.10.1.2.2.1.14
    MIB: F10-S-SERIES-CHASSIS-MIB
  - C-Series: Card temperature (chSysCardTemp)
    OID: .1.3.6.1.4.1.6027.3.8.1.2.1.1.5
    MIB: F10-C-SERIES-CHASSIS-MIB
  - E-Series: Card upper + lower temperature (chSysCardUpperTemp, chSysCardLowerTemp)
    OIDs: .1.3.6.1.4.1.6027.3.1.1.2.3.1.8-9
    MIB: F10-CHASSIS-MIB
  Gap: CRITICAL (no sensors) → RESOLVED
  Parity: 0% → 90%

- priv/profiles/os_discovery/procurve.yaml (enhanced)
  Added HP ProCurve transceiver optical monitoring (5 sensor types):
  MIB: HP-ICF-TRANSCEIVER-MIB::hpicfXcvrInfoTable
  Sensors:
    - Temperature: hpicfXcvrTemp (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.11, divisor 1000)
    - Bias Current: hpicfXcvrBias (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.13, divisor 1000)
    - Supply Voltage: hpicfXcvrVoltage (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.12, divisor 1000)
    - RX Power (dBm): hpicfXcvrRxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.14, divisor 10)
    - TX Power (dBm): hpicfXcvrTxPower (OID .1.3.6.1.4.1.11.2.14.11.5.1.82.1.1.1.1.15, divisor 10)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 100%

- priv/profiles/os_discovery/comware.yaml (enhanced)
  Added HP Comware transceiver optical monitoring (5 sensor types):
  MIB: HH3C-TRANSCEIVER-INFO-MIB::hh3cTransceiverInfoTable
  Sensors:
    - Temperature: hh3cTransceiverTemperature (OID .1.3.6.1.4.1.25506.2.70.1.1.1.15)
    - Bias Current: hh3cTransceiverBiasCurrent (OID .1.3.6.1.4.1.25506.2.70.1.1.1.17)
    - Supply Voltage: hh3cTransceiverVoltage (OID .1.3.6.1.4.1.25506.2.70.1.1.1.16)
    - RX Power (dBm): hh3cTransceiverCurRXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.9, divisor 100)
    - TX Power (dBm): hh3cTransceiverCurTXPower (OID .1.3.6.1.4.1.25506.2.70.1.1.1.12, divisor 100)
  Gap: HIGH (missing transceivers) → RESOLVED
  Parity: 60% → 95%

- test/towerops_web/controllers/api/mobile_controller_test.exs (fixed)
  Fixed Credo warning: replaced length/1 with empty list comparison

- CHANGELOG.txt (updated)
  Documented Tier 1 + Tier 2 completion

Impact:
- Force10 FTOS: Complete temperature monitoring for S/C/E-Series data center switches
- ProCurve: Full optical transceiver diagnostics (SFP/SFP+ monitoring)
- Comware: Full optical transceiver diagnostics (completes sensor coverage)

Business Value:
- All major network switch platforms now have fundamental temperature monitoring
- Fiber optic link health monitoring enabled for ProCurve and Comware
- Data center switches (Force10 FTOS) fully supported
- Enables proactive maintenance (detect failing transceivers before link failure)

Parity Achievement:
- Tier 1 Complete: HP Comware (60→95%), Dell PowerConnect (0→80%), Dell SONiC (0→95%),
  Dell Force10 FTOS (0→90%)
- Tier 2 Complete: HP ProCurve (60→100%), HP Comware (95% - transceivers added)

Next Steps: Tier 3 (storage/compute platforms: PowerVault, Dell Servers, hpblmos)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-12 08:19:12 -06:00
aa9ed52bff
feat: add critical network switch sensor support (HP Comware, Dell PowerConnect, Dell SONiC)
Implemented top 3 critical network switch sensor gaps identified in Phase 3 analysis.
Restores fundamental temperature monitoring for common enterprise switch platforms.

Files Changed:
- priv/profiles/os_discovery/comware.yaml (enhanced)
  Added HP Comware chassis temperature monitoring via HH3C-ENTITY-EXT-MIB
  OID: 1.3.6.1.4.1.25506.2.6.1.1.1.1.12 (hh3cEntityExtTemperature)
  Uses entPhysicalName for sensor descriptions
  Gap: CRITICAL (broke fundamental monitoring) → RESOLVED
  Parity: 40% → 60%

- priv/profiles/os_discovery/powerconnect.yaml (enhanced)
  Added Dell PowerConnect/DNOS CPU temperature monitoring
  OID: 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.43.1.8.1.5
  MIB: FASTPATH-BOXSERVICES-PRIVATE-MIB
  Gap: CRITICAL (no sensors) → RESOLVED
  Parity: 0% → 80%

- priv/profiles/os_discovery/dell-sonic.yaml (new)
  Created comprehensive Dell SONiC sensor profile
  MIB: NETGEAR-BOXSERVICES-PRIVATE-MIB (Quanta-based)
  Sensors:
    - Temperature: boxServicesTempSensorState (OID .1.3.6.1.4.1.4413.1.1.43.1.8.1.4)
    - Fan Speed: boxServicesFanSpeed (OID .1.3.6.1.4.1.4413.1.1.43.1.6.1.4)
    - PSU State: boxServicesPowSupplyItemState (OID .1.3.6.1.4.1.4413.1.1.43.1.7.1.3)
      States: other, notpresent, operational, failed, powering, nopower,
              notpowering, incompatible
  Gap: CRITICAL (OS detected, no sensors) → RESOLVED
  Parity: 0% → 95%

- test/towerops_web/plugs/brute_force_protection_test.exs (fixed)
  Fixed Credo warning: replaced length/1 with empty list comparison

- CHANGELOG.txt (updated)
  Documented Phase 3 analysis completion and critical fix implementation

Impact:
- HP Comware: Enables overheating alerts (fundamental monitoring restored)
- Dell PowerConnect: First sensor support for common access switches
- Dell SONiC: Complete hardware monitoring for modern data center platform

Business Value:
- Resolves production blockers for customers with HP Comware switches
- Adds support for very common Dell enterprise access switches
- Enables monitoring for Dell's modern SONiC-based data center switches

Next Steps: Remaining Tier 1 switches (Dell Force10 FTOS), then Tier 2
(optical transceiver monitoring for ProCurve/Comware).

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-11 17:36:45 -06:00