fix routeros temperature divisor
This commit is contained in:
parent
c4ce7a94ca
commit
12a777d13d
3 changed files with 44 additions and 8 deletions
|
|
@ -606,8 +606,8 @@ defmodule Towerops.Snmp.Profiles.Vendors.Routeros do
|
|||
end
|
||||
|
||||
# Map mtxrGaugeUnit value to sensor type, unit string, and divisor
|
||||
# Based on LibreNMS routeros.yaml - temperature is in whole degrees, voltage/current/power in deci-units
|
||||
defp gauge_unit_to_sensor_type(@gauge_unit_celsius), do: {"temperature", "°C", 1}
|
||||
# Mikrotik reports temperature in tenths of degrees (e.g., 230 = 23.0°C)
|
||||
defp gauge_unit_to_sensor_type(@gauge_unit_celsius), do: {"temperature", "°C", 10}
|
||||
defp gauge_unit_to_sensor_type(@gauge_unit_rpm), do: {"fanspeed", "RPM", 1}
|
||||
defp gauge_unit_to_sensor_type(@gauge_unit_dv), do: {"voltage", "V", 10}
|
||||
defp gauge_unit_to_sensor_type(@gauge_unit_da), do: {"current", "A", 10}
|
||||
|
|
@ -646,7 +646,7 @@ defmodule Towerops.Snmp.Profiles.Vendors.Routeros do
|
|||
|
||||
# Sensor type configurations for overrides (must match gauge_unit_to_sensor_type divisors)
|
||||
defp sensor_type_config("voltage"), do: {"voltage", "V", 10}
|
||||
defp sensor_type_config("temperature"), do: {"temperature", "°C", 1}
|
||||
defp sensor_type_config("temperature"), do: {"temperature", "°C", 10}
|
||||
defp sensor_type_config("current"), do: {"current", "A", 10}
|
||||
defp sensor_type_config("power"), do: {"power", "W", 10}
|
||||
defp sensor_type_config("fanspeed"), do: {"fanspeed", "RPM", 1}
|
||||
|
|
|
|||
|
|
@ -0,0 +1,36 @@
|
|||
defmodule Towerops.Repo.Migrations.FixMikrotikTemperatureSensorDivisor do
|
||||
use Ecto.Migration
|
||||
|
||||
def up do
|
||||
# Update Mikrotik temperature sensors (from gauge table) to use divisor 10
|
||||
# Mikrotik reports temperature in tenths of degrees (e.g., 230 = 23.0°C)
|
||||
# Match by OID pattern: 1.3.6.1.4.1.14988.1.1.3.100.1.3.* (gauge table)
|
||||
execute """
|
||||
UPDATE snmp_sensors
|
||||
SET sensor_divisor = 10
|
||||
WHERE sensor_type = 'temperature'
|
||||
AND (
|
||||
sensor_index LIKE 'mikrotik_gauge_%'
|
||||
OR sensor_oid LIKE '1.3.6.1.4.1.14988.1.1.3.100.1.3.%'
|
||||
)
|
||||
AND sensor_divisor = 1
|
||||
"""
|
||||
|
||||
# Note: Optical table sensors (1.3.6.1.4.1.14988.1.1.19.1.1.6.*)
|
||||
# correctly use divisor 1 and are not affected by this migration
|
||||
end
|
||||
|
||||
def down do
|
||||
# Revert to divisor 1 (incorrect, but reversible)
|
||||
execute """
|
||||
UPDATE snmp_sensors
|
||||
SET sensor_divisor = 1
|
||||
WHERE sensor_type = 'temperature'
|
||||
AND (
|
||||
sensor_index LIKE 'mikrotik_gauge_%'
|
||||
OR sensor_oid LIKE '1.3.6.1.4.1.14988.1.1.3.100.1.3.%'
|
||||
)
|
||||
AND sensor_divisor = 10
|
||||
"""
|
||||
end
|
||||
end
|
||||
|
|
@ -283,10 +283,10 @@ defmodule Towerops.Snmp.Profiles.Vendors.RouterosTest do
|
|||
%{oid: "#{@gauge_table}.2.1", value: "psu-voltage"},
|
||||
%{oid: "#{@gauge_table}.3.1", value: 469},
|
||||
%{oid: "#{@gauge_table}.4.1", value: 3},
|
||||
# CPU Temperature: raw value 45, unit type 1 (celsius) -> should be 45°C
|
||||
# LibreNMS shows Mikrotik temperature values are in whole degrees, not deci-degrees
|
||||
# CPU Temperature: raw value 450, unit type 1 (celsius) -> should be 45.0°C
|
||||
# Mikrotik reports temperature in tenths of degrees (divisor 10)
|
||||
%{oid: "#{@gauge_table}.2.2", value: "cpu-temperature"},
|
||||
%{oid: "#{@gauge_table}.3.2", value: 45},
|
||||
%{oid: "#{@gauge_table}.3.2", value: 450},
|
||||
%{oid: "#{@gauge_table}.4.2", value: 1}
|
||||
]}
|
||||
end)
|
||||
|
|
@ -305,12 +305,12 @@ defmodule Towerops.Snmp.Profiles.Vendors.RouterosTest do
|
|||
assert voltage_sensor.last_value == 46.9
|
||||
|
||||
# Find the temperature sensor
|
||||
# LibreNMS shows Mikrotik temperature values are in whole degrees (divisor 1)
|
||||
# Mikrotik reports temperature in tenths of degrees (e.g., 450 = 45.0°C)
|
||||
temp_sensor = Enum.find(sensors, &(&1.sensor_descr == "cpu-temperature"))
|
||||
assert temp_sensor
|
||||
assert temp_sensor.sensor_type == "temperature"
|
||||
assert temp_sensor.sensor_unit == "°C"
|
||||
assert temp_sensor.sensor_divisor == 1
|
||||
assert temp_sensor.sensor_divisor == 10
|
||||
assert temp_sensor.last_value == 45.0
|
||||
end
|
||||
|
||||
|
|
|
|||