Three signal sources we already collect but weren't using: * NEXRAD composite reflectivity → rain rate via Marshall-Palmer, taken as max of HRRR-derived and NEXRAD-derived rate so fast convective cells between HRRR hourly analyses can still trigger the rain penalty. Only active on f00 — forecast hours can't see future radar. New Scorer.dbz_to_rain_rate_mmhr/1 with 5 dBZ noise floor and 150 mm/hr hail-safe ceiling. * hrrr_native_profiles.best_duct_band_ghz → Scorer.score_refractivity/4 applies a 1.15× boost when the cell's native-resolution duct supports the target band's frequency. HRRR pressure-level gradients systematically under-read thin trapping layers the native profile can resolve. Sub-band ducts do NOT boost — they're evidence that the gradient we have is all there is at the target frequency. * Commercial LOS link rx_power fading → inverse tropo sensor. Commercial.link_degradation_at/3 computes the average 7-day-baseline vs current delta across enabled links within 75 km, ignoring links where link_state != 1. Scorer.commercial_link_boost/2 adds +2 to +25 to the composite score for 3+ dB of fading. ~150 km radius around DFW is the only zone this helps today, but it's the first *measured* signal in the algorithm vs the model-derived proxies. Also fix a latent test bug exposed by the earlier ERA5 poll-timeout bump: era5_batch_client_test's "uncached path returns error" tests hung for up to an hour when run with direnv's real CDS key. New describe-level setup explicitly unsets the env var so the tests stay hermetic. 1,359 tests, 0 failures. |
||
|---|---|---|
| .. | ||