Batched from a system-wide review pass.
**Rate-limit + transient-error log hygiene**
- WeatherFetchWorker: classify IEM HTTP 429 as {:snooze, 300} instead
of {:error}. Stops Oban.PerformError stack-trace spam on every
routine rate-limit during backfill, keeps the retry semantics.
- IonosphereFetchWorker: compress GIRO TLS :unknown_ca error from a
~400-char inspect blob to 'TLS unknown_ca (CA bundle missing)'.
- FreshnessMonitor: log only when an enqueue actually lands (the
Oban unique conflict case was silently dropping jobs but still
producing 'enqueuing grid worker' info lines every 5 minutes).
**Perf**
- Rust grid_level_keys(): pre-format 'TMP:{p} mb' / DPT / HGT keys
once via OnceLock instead of format!()'ing per-cell. Removes ~3.6M
String allocations per f01..f18 chain step across pipeline.rs,
hrrr_points.rs. Same for the wgrib2 :(TMP|DPT|HGT): pattern in
hrrr_points.process_batch (sfc_pattern / prs_pattern OnceLock).
- MapLive preload_forecast: Task.async_stream with max_concurrency=4
replaces the 18-wide Enum.map serial walk. Forecast cache warms
~4× faster after a band change, with ordering preserved.
- grid_tasks: partial composite index on (run_time DESC,
forecast_hour ASC) WHERE status='queued' AND kind='forecast',
matching the Rust claim query's ORDER BY. Drops the old
status-only partial that forced a sort per claim.
**Correctness**
- ContactImportWorker: add Oban unique:[keys: [:import_run_id,
:offset]]. Was missing on a worker whose perform() does a
non-idempotent atomic counter increment — a retry would double-
count imported rows.
- CommonVolumeRadarWorker: x_min..x_max default step is -1 when
x_min > x_max, triggering a runtime deprecation warning. Force
Range.new(_, _, 1) explicitly.
**Cleanup**
- Drop unused tmp_dir parameter from hrrr_point_worker + its
process_batch signature.
First step toward physics-based HF / sporadic-E scoring. Polls GIRO's
DIDBase tabular endpoint every 10 minutes for two US ionosondes
(Millstone Hill MHJ45, Alpena AL945), parses the plain-text response
into observation rows, and upserts into a new ionosonde_observations
table keyed on (station_code, valid_time).
This gets foEs (E-layer sporadic critical frequency) into the database
as a direct measurement — the key input for predicting 144 MHz Es
openings via ITU-R P.534-6. foF2 + MUFD are the F2-layer inputs for
HF MUF predictions.
Not yet wired into scoring. Boulder/Wallops/Austin/Idaho/Point Arguello
are in the GIRO catalog but were silent when probed — add them back
if/when they come online.
Next steps: SWPC JSON (Kp, F10.7, sunspot), GOES X-ray flux, D-RAP text,
and the P.534-6 Es scoring factor that uses foEs at midpoint for the
144/440 band configs.